Loading...
SFD (05-1826)60755 Living Stone Dr 05-1826 Application Number: X05 00601826_. Property Address: 66755 LIVING STONE DR APN: 764-999-270-15 -300234- Application description: DWELLING - SINGLE FAMILY Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: .139594 Applicant: BUILDING & SAFETY DEPARTMENT T Architect or Engineer: V " . A. ta, . 6a, LiL 05 Owner: SHEA" LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE, AZ 852581. Contractor: SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253 (760)777-6005 Lic. No.: 672285 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153. Date: 5/19/05 LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION _ hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License•No.: 672285 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is - / [� / Date: ontractoc �LL /7D/il� - issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My -workers' compensation - OWNER -BUILDER DECLARATIONinsurance _ carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier NTL UNION INS Policy Number 6436568 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I. shall not employ any - construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he of she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section .. License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. ' that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 •.5 by - - C /'w' any applicant for a permit subjects the applicani: to a civil penalty of not more than five hundred dollars.($ 500).:ate: pplicant:- •��• (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does.not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - and who does the work himself or herself through his or her own employees, provided that the DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - - APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the -. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for - pursuant to the Contractors' State LicenseLaw.). - whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and holdharmlessthe City - of La Quinta, its officers, agents and employees for any act or omission related to the work -being _ - .. performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced - - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject ' CONSTRUCTION LENDING AGENCY . permit to cancellation. _ I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I'have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). ' city and county ordinances and state laws relating to building construction, and hereby authorize repres ntatives of this cWttenter upon above.mentioned property for ' ion ur oses. Lender's Name: Signature (Applicant or Agent): . :te: Lender's Address: LQPERMIT -Application Number 05-00001826 Structure Information.. SFD PLAN 4510 W/MBR BAY'26SF Construction Type TYPE V - NON RATED Occupancy Type DWELLG/LODGING/CONE <=10 Other struct info.. . . . . CODE EDITION .2001 ,. # BEDROOMS 3,.00 FIRE SPRINKLERS NO GARAGE SQ FTG 479.00 PATIO SQ FTG 337.00 NUMBER 'OF UNITS 1.00 IST FLOOR SQUARE FOOTAGE 1556.00• Permit BUILDING PERMIT Additional desc., Permit Fee 779.50 Plan Check Fee .126.67 Issue Date Valuation 139594 Expiration Date : 11/15/05 Qty Unit Charge Per -Extension BASE FEE 639.50 40.00 3.5000 THOU BLDG 100,001-500,000 140.00 Permit =MECHANICAL Additional.desc Permit Fee 83:50 Plan Check Fee : 5.22 Issue Date Valuation . . 0 Expiration Date 11/15/05 -: Qty Unit Charge Per' Extension 1. BASE FEE 15.00 2.00 9.0000•EA MECH FURNACE <=100K 18.00_ 2.00 9.0000-EA- MECH B/C <=3HP/100K BTU 18.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 _PermitELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 79.04 Plan.Check Fee 4.94 Issue Date Valuation . . . 0 - Expiration Date 11/15/05 Qty Unit Charge Per Extension BASE FEE 15.00 1556.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 54.46 • 479.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.58 Permit . . . . . . PLUMBING - " Application Number 05-00001826 Permit PLUMBING Additional desc . Permit Fee 123.00 Plan Check Fee 7.69 Issue Date . . Valuation . . . . 0 Expiration Date. 11/15/05 Qty Unit Charge 'Per Extension BASE FEE 15.00 9.00 6.0000 EA PLB FIXTURE 54.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB.WATER HEATER/VENT 7.50 . 1.00 3.0000 EA PLB WATER INST/ALT/REP 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 7500 EA PLB GAS PIPE >=5 4.50 1.00 15.0000 EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 11/15/05 Qty Unit Charge Per, Extension BASE FEE 15.00 Special Notes and Comments _ SFD -,Lot 15 Plan 4510C (1556 sgft) w/MBR Box Bay (26 sqft). Permit does not include block wall, pool or driveway approach. 75.% REDUCTION TO -PLAN CHECK FEE DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE. 2001 CBC - Other Fees . . . . . . . ART IN PUBLIC'PLACES-RES• .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC.CENTER - RES 366.00 ENERGY REVIEW FEE 12.67 DIF FIRE PROTECTION -RES 97:00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 ' DIF PARK MAINT FAC = RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) = RES 13.95 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary, Charged Paid. Credited ---------------------------------------- Due ----------------- Permit Fee Total 1080.04 .00 .00 1080.04 C. J LQPERMrr PREPARED 3/16/11, 10:21:44 _ INSPECTION HISTORY REPORT. PAGE 1 ' PROGRAM BP521L -0/00/00 THRU 0/00/00 - CITY OF LA QUINTA --------------------------------------------------------------------------------------------- APPLICATION PROPERTY ADDRESS APN ------------------------------------ ------------- Alternate ID - -APPLICATION - - .STRUCTR ------------------------------=----------------------------------=---------------------'---------------------------------------------•- .PERMIT. INSPECTION RESULT DATE/STATUS INSPECTOR _ .. 05 00001826 60755 LIVING STONE DR 764-430-015- - - - - - 000 000 BO01 00 BUILDING PERMIT .120 ,0001 FOOTINGS 6/27/05 APPROVED GH - - - 000 000 B601 00 BUILDING PERMIT 125 0001 SLAB 6/27/05 APPROVED GH - 000 000 B001 00 BUILDING PERMIT 135 0001 ROOF NAIL 7/29/05 APPROVED. GH • 000 000 B001 00 BUILDING.PERMIT - 140 0001 OKAY TOWRAP8/08/05 APPROVED GH - '. 000 000 B001-00 BUILDING PERMIT - 145 0001 FRAMING 8/12/05,APPROVED GH ' • 000 000 B001 00 BUILDINGPERMIT 150 0001 INSULATION - 8/17/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 155 0001 LATH 8/19/05 APPROVED GH 000 000 B001 00 BUILDING PERMIT 160 0001'.DRYWALL NAIL -- 8/19/05 APPROVED GH ' 000 000 E01 00 ELEC-NEW RESIDENTIAL 310 0001 ROUGH ELECTRICAL 8/12/05 APPROVED GH' - -000 000, ..EO1 00 ELEC-NEW RESIDENTIAL• 315 0001 TEMP USE OF PERMANENT POW 9/20/05 APPROVED '- GHQ . 000 000 M01 00 MECHANICAL 405' 0001 ROUGH MECHANICAL .8/12/05'APPROVED GH . 000.000 P01 00 PLUMBING 210 0061 SEWER CONNECTION 6/20/65 APPROVED •GH 000 000- P01 00 PLUMBING .. 200 6001 UNDERGROUND PLUMBING' 6/20/05 APPROVED - GH 000 000 P01 00 PLUMBING 230 .0001 ROUGH PLUMBING - .. 8/12/05 APPROVED GH -•. 000 000 P01 00 PLUMBING - 245 0001 SHOWER PAN 8/12/05 APPROVED, . GH - ' -000'000 P01 00 PLUMBING 235 0001 GAS LINE / GAS TEST. :9/12/05 APPROVED. - GH - JCM Inspections 39725,13arand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA ❑✓ IBC ❑Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Slump (inches): (p , tDo Supplier: Superior Time Sampled: p a ckr Mix Design: D83625P Time in Mixer (min.): -70 Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): �� Addmixture: POZZ 322N Concrete Temperature (F): Truck #: ro") S Ticket #:_1 y - Ambient Air Temperature (F): Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: PKNone ❑ see Below Location of Sample: �l p.� ort V�Ifoa ❑ No Samples Taken Description of Work Inspected: Phase Qj Lot# !� Product Plan —7 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15.18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson .Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional 'N rebar placed as per these details and as noted on Sa-(1 v,d, uldi n 1L P �w�c�o �,� f✓ V'(1QS C r oust - Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. (- AS-C'i'�;7 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. L—.Q 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx . Verified correct mix design. I hereby certify that i have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICCvCertification No: 0842216-80 �o r C' Contractor's Reprresdintative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page 4— of iCIVI Inspections 39725 Garand Lane Suite F DE"' Palm Desert, CA 92211 R=D= INSPECTIONS Phone: 760-345-5554 Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: IBC 81-260 Avenue 62 La Quinta, CA F-] Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect:. Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc, Inc/Suncoast Post Tension LP Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved. Tendons Unresolved-ltdms: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips psi to 33.04 kips/33,000 lbs' None ❑ See Below Calibration Date: Machine # Phase k I 9Lot# 4 o ProductU N _LPIan t44� Q C, 6 Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons. Elongation (in) Reference 11h/SN2. L4 L4 o) SZ Yes No (SIr" LA -A- 14 -4 � 13 Ir 1:1 frga R El. %A 61 f I i - ) X -IN llf 0 *IX I A- 43 14 Er El El El ET El 1:1 -E] El 1:1 I hereby certify that I have inspected all of the above work, unless,otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report issued at project completion. Inspector: Ja k C Millin ICC C iftatio o:0842216-89- S Contractoes Reprie'sentative: _ Q�r c'` �'`1�✓' Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page - Of e, 10/06/2005 16:12 FAX PARAGONPSCHIMID [A 010/012 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at U ;55-L-IVIG-STONE-DtIUE, LOT 4015, PHASE 118, LA 4UINTA, CA CEILINGS:. TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38 WALLS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAGON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 TITLE: ACCOUNT REPRESENTIVE DATE: BY: - - ... • may,. • � yam. J . t , Ca10ERTS Certified Rating Furnace: 0.8 October, 13 2005 This Compliance rating is for the home located at: 60755 Living Stone Drive La Quinta CA, 92253 Certificate Number: CC3- 1798350970 ' Date Inspected: October, 11 2005 Duct Insulation R -Value: Ca10ERTS Rater: William t ' ip d j • Henson Water Heating S stem Pro osed TY Size I Fuel I EF Distribution HERS Analyst: N/A '. Builder/Developer: Shea.y Homes, Inc. ' -Trilogy @ Project: La Quinta Plan Name: 4510' Lot Number: 015 Ph - 11 g G•�_''7S �[,y�y�0 S�oN e %�Y Specifics about this home: General Information Conditioned Floor Area: 1700 Square Feet ' Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution R Value Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 96.0 Water Heating S stem Pro osed TY Size I Fuel I EF Distribution Water He atin S stem Actual TY I Size Fuel I EF Distribution Building Envelope Surface Area Proposed Actual R U Value I Factor R Value . U I Factor Windows E TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I , PALM DESEERT, CA. 92211 PHONE: 760-772-2954 I __414A(a� CERTIFYING SIGNATURE , DATE J Proposed Actual SHGC I U Value SHGC U Value Orientation Area E TESTED (PAGE 1 OF 2) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I , PALM DESEERT, CA. 92211 PHONE: 760-772-2954 I __414A(a� CERTIFYING SIGNATURE , DATE J Testing Results Main System HVAC System Tested Duct Leakage: Iyes - Passed Tested Leakage Flow in CFM: 66 00cfm/ton x number of tons: 1600 Leakage Percentage (100 x Test Leakage/Fan Flow) .1 Tested TXV: Yes - Passed' Thermostatic Expansion Valve is installed and Access is provi&d for inspection. Tested Duct Design 'Comliance: N/A Tested Duct in Conditioned Space: N/A Tested Reduced Duct Surface N/A Area: Tested Infiltration Reduction N/A Credit: The energy efficiency rating of this home is determined using CaMbmis Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household_ Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only atter the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact-- CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. (PAGE 2 OF 2 i - PHASE • LOT I i