Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SFD (05-3375)
60920 Living Stone Dr 05-3375 'Application description: DWELLING - SINGLE FAMILY Property Zoning: . MEDIUM HIGH DENSITY RES Application valuation: 123721 BUILDING & SAFETY DEPARTMENT. -- BUILDING PERMIT r46'6 Owner: ) SHEA LA QUINTA C/O JEFF MCQUEEN DETACHED ' cam; ;tom 8800 N GAINEY CENTER 350 �J! SCOTTSDALE, AZ 85258 Applicant: Architect or Engineer: q0 ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License C ss• B LicenseNo.: 672285 4 ate:#� Contractor. mom\ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the . following reason (Sec. 7031.5., Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or . that he *or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for apermit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are.not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - (_ 1 I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. . 7044,.Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.)." 1 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT . Contractor: SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253 (760)777-6005 Lic. No.: 672285 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153. Date: 8/02/05 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is �t issued. - i' lave and will maintain workers' compensation insurance, as required by Section 3700 of the'Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NTL UNION INS Policy Number 6436568 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 700 of the Labor Code, I shall forthwith co ply with those provisions. WARN( G: 1AILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, . the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. " 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work. for 180 days will subject permit to cancellation. _ I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby auth representatives of thisco ty o enter upon a above-mentioned property fo ection purposes. , Ike,: ignature (Applicant or Agent): Application Number 05-00003375 ------ -Structure Information. PLAN 4210A W/26 SF BOX ----- - Construction Type . . . . TYPE.V - NON RATED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 Other struct info . . .. . . CODE EDITION .2001 • #-BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 474.00 PATIO SQ FTG 214.00 . NUMBER'OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 1381.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 723.50 Plan Check Fee 117.57 Issue Date . . Valuation 123721 Expiration Date, 1/29/06 Qty Unit Charge Per Extension BASE FEE 639.5'0 24.00 3.5000 THOU BLDG 100,001-500,000 84.00 Permit. . . . MECHANICAL Additional"desc . Permit Fee . . . . 65.50 Plan Check Fee 4.10 Issue Date Valuation . . . . 0 Expiration bate .1/29/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 _ 4.00 6.5000 EA MECH VENT FAN 26.00 . 1.00 6.5000,EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 72.82 Plan Check.Fee 4.55 - ` Issue Date . . . . Valuation . . . . 0 Expiration Date 1/29/06 Qty Unit-Charge ;Per Extension BASE FEE 15..00 " 1381.00 .0350. ELEC NEW RES - 1 OR 2 FAMILY 48.34 474.00 .0200• ELEC"GARAGE OR NON-RESIDENTIAL 9.48 LQPERMIT Application Number . . . . 05-00003375 Permit . . . PLUMBING Additional desc . Permit Fee . . .'.. 122.25 Plan Check Fee 7.64 Issue -Date Valuation 0 Expiration Date-. 1/29/06 Qty Unit,Charge Per Extension BASE FEE 15.00 9.00 6.0000 EA PLB FIXTURE 54.00 1.00• 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000_EA PLB WATER HEATER/ -VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP, 3.00 1.:00 9.0000'EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE.>=5 3.75 1.00 15..0000 EA PLB GAS METER 15.00 . Permit GRADING PERMIT .. Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date 1/29/06 Qty Unit Charge Per Extension BASE FEE 15.00 Special' Notes and Comments SFD Lot 121 Plan 4210B (1381 SF) w/MBR Box Bay, (26 sqft) . PERMIT DOES NOT -INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. ---------------------------------------------------------------------------- Other Fees . . ... . . . . . ART IN PUBLIC PLACES -RES -.00 DIF COMMUNITY CENTERS=RES 97-.00 DIF CIVIC CENTER -RES 366.00 ENERGY REVIEW FEE 11.76 •DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00' DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00' STRONG MOTION (SMI) - RES 12.37 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary.. Charged Paid Credited .. Due ' . LQPERMIT _ - Application Number 05-00003375 Permit Fee Total: 999.07 .00 .00 999.07 Plan Check Total 133.86 .00 .00 133.86 Other Fee Total 2429.13 .0.0 .00 2429.13 Grand Total 3562.06 .00 00 3562.06 l JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 I N S P E CT 10 N s .. Phone: 760=345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta; LLC Date:. . 11/29/05; Project: Trilogy @ La Quinta -Shea Homes Project No: 02.4109 ,.81-260_Avenue'62 - La,Quinta,'CA 92274.. Set'ID Structure : Age of Test Compression Strength JCM.ID, Locadon . Date Cast . Cylinder ID (days) (psi) Set A Phase 1213 -tot #4121 ' Slab on Grade 8-30-05 Concrete 273-593Great Room Required psi: 4000 < 1114 7 (OCU-cfZD L,Iv;r, 2390. 111$ 28 .4350 1116.. • 28 .. 4400 JCM Inspections 39725 Garand Lane Suite F. Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 L --M- INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA 0✓ IBC E] Title 24 Other: Client: Sub -Contractor: . Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips 5=r ,0 psi to 33.04 kips/33,000 lbs Calibration Date: Machine # / a� 8 _3 �—o — Phase Lot# L4 loZ Product Plan )t7� 6 o Weather: t n Unresolved Items: None ❑ See Below Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. ��LL �I— Yes No -3 k. 114 ❑ ©- ❑ 40 0'r ❑ El— ❑ Ek El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Ja k C. Millin ICC Certification0:0842216-89 XA Contractor's Representative: Copy 1 JCM InspectionsCopy 2 Project Superintendent -Copy 3 Governing Agency '�� Page of _ JCM Inspections „. 39725 Ga_ragd Lane Suite F Palm Desert, CA 92211@=== 8" INSPECTIONS Phone: 760-345=5554 - Fax•,760-7:72-3895 INSPECTIONS ,T REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 ¢; La Quinta, CA [?]'IBC ❑Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Slump (inches): G, oo Supplier: Superior Time Sampled: 0, ��— �� Mix Design: D83625P Time in Mixer (min.): tp p Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): , Addmixture: POZZ 322N Concrete Temperature (F): 90 Truck #: Ticket #: Ambient Air Temperature (F): 0 G Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: EJ None ❑ See Below Location of Sample: S, a\j 011% Gr' o k o — G t o A- gon._ ❑ No Samples Taken Description of Work Inspected: Phase Lot# `l �a Product J Plan o S^ 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (1.1,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on �' _ I I t n 0 (1-IE ck 4 U , n Q� n f-. Q A Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. -3o-a 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. 00 -31-os 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certifc on No: 0842216-80 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent __ 1--_-Copy.3.- Goveming Agency Page --I— of j " bEc 20,2005 19:22 BCI*TESTING,ri1 000-000-00000 Page 3 CaICERTS Certified Rating December, 20 2005 This Compliance rating is for the home located at: 60920 Living Stone Drive Conditioned Volume: , La Quinta CA, 92253 Certificate Number: CC3-1/98353902 f Date Inspected: December, 19 2005 _J CaICERTS Rater: William Henson•. PI SHGC I CC2004076 HERS Analyst: N/A l _ Builder/ Developer: Shea Homes, Inc. rj Project: Trilogy @ La Quinta T. Phase: Phase 12B Plan Name: 4210_ •S_ Lot Number: 01.21 Specifics about this home: General Information Conditioned Floor Area: 1500 Square Feet Conditioned Volume: 11 Cubic Feet Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 17 HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Dud Insulation R -Value: 6 Air InF/tration Blower Door Target: 96 Water Heatino S stem PI'o osed TY I Size Fuel I EF Distribution Water Heating System Actual TY I Size I Fuel I EF Distribution Testing Results ain System HVAC System Area ested Duct Leaka e: Yes - Passed ested TXV: Yes- Passed ested Duct Design Compliance; N/A ested Duct in Conditioned Space:' N A ested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A Building Fnvelope Surface Area Pro osed Actual R Value U Factor R Value U Factor Windows F7X TESTED (PAGE i OF i) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADORES 77.760 COUNTRY CLUB DRIVE, SUITE I " PALM DESSERT, CA. 92211 PHONE: 760.772.2964 i ClffhTIFYINQ SIGNATURE DAT The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) Riles. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Boz 6600, Folsom, CA 95763. Proposed Actual Orientation Area U U SHGC Value SHGC I I Value F7X TESTED (PAGE i OF i) =APPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADORES 77.760 COUNTRY CLUB DRIVE, SUITE I " PALM DESSERT, CA. 92211 PHONE: 760.772.2964 i ClffhTIFYINQ SIGNATURE DAT The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) Riles. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Boz 6600, Folsom, CA 95763.