SFD (05-3376)
60930 Living Stone Dr 05-3376 Application Number: 05-00003376 ~l Owner: Property Address: 60930 LIVING' -STONE DR SHEA LA QUINTA APN: 764-210-999-120 -300234- C/O JEFF MCQUEEN- Application description: DWELLING - SINGLE FAMILY DETACHED 8800 N GAINEY CENTER 350 Property Zoning: MEDIUM HIGH DENSITYRES- ® SCOTTSDALE, AZ 85258 Application valuation: 185294 D pu� 1 Z�OJ Contractor: Applicant: /Architect or Engineer:. N SHEA HOMES, INC. of: LP, Clu t0A 81260 AVENUE 62 CEDEvr• LA QUINTA, CA 92253 (760)777-6005 Lic No.: 672285 CW q10(' -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License C ss: B Li nse No.: 672285 Date: a ontractm OWNER -BUILDER DECLARATION I hereby irm under penalty of perjury that I am exempt from the Contractor's State License Law for the ' following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The ' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who doesthe work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden.of pioving that he or she did not build or improve for the purpose of sale.). ' ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - (_ 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance ofthe work for which this permit is issued (Sec. 3097, Civ. C.). ' Lender's Name: Lender's Address: ,v LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: ,8/02/05 WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Se6on.3700 of the Labor Code, for the performance of the work for which this permit is issued. A I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier NTL UNION INS Policy Number .6436568 _ Icertify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, *G:FAILURE agree that, if I should become subject to the workers' compensation provisions of Section 0 of the Labor Code, I h II forthwith co pl with those provisions. opplicant: WARTO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND. ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2:' Any permit issued as a result of this application becomes null and void if work isnot commenced within 180 days from date of issuance of such permit, or cessation of work f6r 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I to comply with all city and county ordinances and state laws relating to building construction, and hereby th ze representatives of this cou y to nter upon above-mentioned property fo ction purposes. te: gnature (Applicant or Agent): Application Number 05=00003376 ------- Structure Information PLAN 5515C W/MBR 26SF ----- Construction Type . . . . . TYPE V - NON RATED Occupancy Type DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . •. NON -AO FLOOD ZONE Other struct-info CODE EDITION 2001 ## BEDROOMS 3.00 FIRE SPRINKLERS NO . GARAGE�SQ FTG 478:00 PATIO SQ FTG 178.00 NUMBER OF. UNITS 1.00 ----------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 2148.00 Permit BUILDING PERMIT , Additional. desc . Permit Fee .940.50. Plan Check Fee 611.33 Issue Date Valuation : 185294 Expiration Date 1/29/06 Qty Unit Charge Per Extension BASE FEE 639.50 86.00 3.5000 ---------------------------------------------------------------------- THOU BLDG 100,001-500;000 301.00 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 66.50 Plan Check Fee 16.63 Issue Date . . . Valuation 0 Expiration Date 1/29/06 Qty Unit Charge. Per Extension BASE FEE 15.00 1.00 9:0000 EA MECH FURNACE <=100K 9.00 1.00- .16.5000 EA MECH B/C >3-i5HP/>100K-500KBTU 16.50 3.00 6.5000 -EA MECH VENT FAN 19.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc,. Permit Fee . . . . 99.74 Plan Check Fee 24:94 Issue Date Valuation . . . . 0 Expiration Date .. 1/29/06 Qty Unit Charge Per Extension. BASE FEE 15.00 2148.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 75..18 LQPERMIT Application Number . . . . . 05-00003376 Permit . . . . . . ELEC-NEW RESIDENTIAL ' Qty Unit Charge Per Extension _ 478.00 .0200- ------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 9.56 Permit PLUMBING • Additional desc'. Permit Fee . . 141.00 Plan Check'Fee 35.25 Issue Date .. . . . Valuation 0 Expiration Date 1/29/06 Qty Unit Charge Per Extension BASE FEE 15.00 12.00 6.0000 EA PLB FIXTURE 72.00. 1.00 15.000.0 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA :PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE. >=5. 4.50 7 1.00 15.0.000 EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . 15.00 Plan Check Fee .00 _. Issue Date . . . Valuation . . . 0 Expiration. Date 1/29/06 Qty Unit Charge Per Extension BASE FEE 15.00. ---------------------------------------------------------------------------- Special Notes and Comments SFD - PLAN 5515A LOT 120,.2148 SQFT -- W/MBR 26SF. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL OR.DRIVEWAY,APPROACH -------------------------------------------- Other Fees . . ... ... . . . ART IN PUBLIC.PLACES-RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 61.13 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES. --RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 18.52 DIF STREET•MAINT FAC -RES 15.00 LQPEnlFr -.- - - - - - Application Number. 05-00003376 ------------------------ Other Fees . . ----------- . . -•---------- - - DIF TRANSPORTATION --------------------- - - -- - RES 1098:00 Fee summary .Charged ----------- Paid ------- Credited Due -------------- Permit Fee Total .1262.74 .00 .00. 1262.74. Plan Check Total 688.15 .00 .00 688.15 Other Fee Total- 2484.65 .00 .00 2484.65 Grand Total 4435.54 00 .00 4435.54 .. PREPARED 3/16/11, 10:21:53 INSPECTION HISTORY REPORT PAGE 1 .' .PROGRAM BP521L 0/00/00 THRU 0/00/00 _ CITY.OF LA QUINTA ---_---------- --------------------------------------------------- -------------------------------------------------------------- APPLICATION PROPERTY ADDRESS APN. - Alternate ID _ -.- STRUCTR PERMIT - INSPECTION RESULT DATE/STATUS INSPECTOR 05 00003376. 60930 LIVING STONE DR - 764-270-999-120,-300234- 000 000 B001 00 BUILDING PERMIT 125. 0001 SLAB 8/31/05 APPROVED GH 000 000 8001 00 BUILDING, PERMIT _ ".120. 0001 FOOTINGS 8/31'/05 APPROVED GH. 000 000 -B001 00 BUILDING PERMIT, 135. 0001 ROOF NAIL 10/04/05 APPROVED '. GH. 000 000 8001 00 BUILDING PERMIT _ 140 0001 OKAY TO WRAP 10/18/05 APPROVED GH 000 000 5001'00 BUILDING PERMIT - - -145 0001 FRAMING 10/20/05 APPROVED. GH 000 000 B001.00 BUILDING PERMIT 150 0001 INSULATION . 10/24/05 -APPROVED GH - 000 000. BO01 00 BUILDING PERMIT '. -\ 155 0001 LATH 10/27/05 APPROVED GH ' -000 000 B001 00 BUILDING PERMIT• 160 0001 DRYWALL NAIL 10/27/05 APPROVED _ GH 000000 B001 00 BUILDING PERMIT 199 0001 FINAL 1/11 /06 APPROVED .. GH 000 000 E01 00 ELEC-NEW RESIDENTIAL 310 '000I.ROUGH ELECTRICAL 10/20/05*APPROVED .. GH- 000,000 E01 00 ELEC-NEW RESIDENTIAL 315 .0001 TEMP USE OF PERMANENT POW 12/01/05 APPROVED IGH • 000 000 E01 00 ELEC-NEW RESIDENTIAL .399 .0001., ELECTRICAL FINAL 1/11/06 APPROVED - _ GH . 000,000 GP 00 GRADING PERMIT 197 0001 GRADING FINAL - 1/11/06 APPROVED - GH- 000'000 M01 00 MECHANICAL 40.5 '0001 ROUGH MECHANICAL. .10/20/05 APPROVED GH _ 000 000 M01 00 MECHANICAL 4.99' 0001 MECHANICAL FINAL � i/11/06 -APPROVED GH - - 000 000 P01. 00 PLUMBING 210 0.001 SEWERCONNECTION- 8/22/05 APPROVED GH - 000 000 '-P01 00 PLUMBING.' .200' 0001 UNDERGROUND :PLUMBING. 8/22/05 APPROVED '- GH 000 000 PO1 00 PLUMBING ', 230 0001 ROUGH PLUMBING 10/20/05 APPROVED^ GH -000 000 P01 00 PLUMBING .• 235 0001' -GAS LINE / GAS -TEST 11/16/05 APPROVED GH 000 000 P01 00 PLUMBING . 299 0001 PLUMBING FINAL 1/11106 APPROVED GH JCM Inspections 39726 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 -fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta,,LLC, Date: 11129105. Project:.Trilogy: @ La Quinta -Shea Homes Project No: 02-11.09 81-260 Avenue 62 'La Quinta,'CA 92274. Set 1D Structure . Age of Test Compression Strength JCM ID Location Date Cast . Cylinder ID (days) Set A Phase 12B - Lof# 4120' Slab on Grade 9-1-05 Concrete 273 595. Kitchen Required psi: 4000 1158 7 3060 n 1159 28 4470 Q V1 A '-/ 1160 28 4540 . JCM Inspections ERA 39725 Garand Lane Suite F Ll= Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: �✓ IBC 81-260 Avenue 62 . La Quinta, CA . ❑ Title 24 Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Weather: Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons �llnnl Unresolved9 ems: :Jack Machine Calibration: Received Sheet from Sun.Coast-Gage Pressure in psi to Machine Load in kips ® None psi to 33.04 kips/33,000 lbs ❑ See Below Calibration Date: Machine #� Phase Lot# ,apProductx Plan Description of Work Inspected: Actual Elongation (in), Specified 'Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 11 h/SN2. A W On Yes No e:4 r ❑ t 3/ © ❑ ^ ❑ ❑ El e - 7 ca- ❑ a ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ' lCC CertificationNo:8'42216-89 Contractoes Representative: t Copy 1 JCM Inspections Copy 2 Project Superintendent /Copy 3 Govemi g Agency Page of JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA ❑✓ IBC EJ Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): `i . �,� Supplier: Superior Time Sampled: lis' 30 Mix Design: D83625P Time in Mixer (min.): L, < Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.):. p Addmixture: POZZ 322N .Concrete Temperature. (F): 4RO Truck #: qlo_ Ticket #: +�ds Ambient Air Temperature (F): tAi Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: E] None ❑ See Below Location of Sample: SIA an' . a n at o -AL _ 1.4 At) e rq ❑ No Samples Taken Description of Work Inspected: Phase Lot# L LQ0 Product Plan SS) y (oD — -3a Uv wl g�3 1 —0.� 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD--11), Anchor Bolts and Holdowns (6,7,8/SDt,-1), Pad Footings and additional rebar placed as per these details and as noted on s 3—) i.-� O k � W i n h o ui (— MeAmef- Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. ' Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx �$ A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. 1).The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 1 Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. illin ICC Certificat'on N . 0 2216-80 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent i'` Copy 3 Governing Agency — ' Page of _ :)EC�20, 2005 19:22 ' BCI*TESTING, ril '- " 000-000-00000 Page 4 CaICERTS Certified Rating December, 20 2005 This Compliance rating is for the home located at: 60930 Living Stone Drive La Quinta CA, 92253 ' Certificate Number: CC3-1798353903 i Date Inspected: December, 19 2005 RU Value CaICERTS Rater: William Henson , C CC2004076, N%A , F HERS Analyst: Value Builder/Developer: Shea Homes, Inc. fj Project: Trilogy 0 La Qulnta T Phase: Phase 12B Plan Name: 551.5 •S Lot Number,1Z0 Specifics about this home: General Information Buildinq Envelope . Conditioned Floor Area: 2100 Square Feet Conditioned Volume: 0 Cubic feet Front Orientation: N/A Surface Area Proposed Actual R Value I I U Factor RU Value , Factor Number of Stories: Win rin we Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 HVAC Air Distribution Area Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 4. Value +, Proposed Actual Orientation Area ested Duct Design Compliance; U Tested Duct In Conditioned Space: V Tested Reduced Duct Surface Area: N/A SHGC Value SHG C Value Ail Infiltration Blower Door Target:- 120 +;OTESTEO (PAGE i OF 1) Water Heating System Proposed =APPROVED AS PART OF SAMPLE GROUP TY Size Fuel I EF Distribution FIRM: BCI TESTING Water Heating System Actual ADORES 77-760 COUNTRY CLUB DRIVE, SUITE I TY "Size I Fuel I EF I Distribution ' PALM DESEERT, CA. 92211 PHONE: 760-772.2964 Taatinn RPsu/Cs Main System HVAC System ested Dud Leakage: Yes - Passed ested TXV: Yes- Passed ested Duct Design Compliance; N/A Tested Duct In Conditioned Space: N/A Tested Reduced Duct Surface Area: N/A ested Infiltration Reduction Credit: N/A r TIFYING SIGNATURE DATLY The energy efficiency rating of this home is determined using California Home Energy Rating System (C•I1ERs) rules. The rating considers heating, cooling and watei heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. Y