SFD (05-3374)60945 Living Stone Dr
05-3374
Application description
Property Zoning:
Application valuation:
Applicant:
0.5 0.0.0033.7
60945 LIVING STONE DR
764-270-999-38 -300234-
DWELLING.—SINGLE
300234-DWELLING—SINGLE FAMILY
MEDIUM HIGH DENSITY RES
150034
rchitect or
BUILDING & SAFETY. DEPARTMENT
BUILDING PERMIT
DETACHED.
Owner:
SHEA LA QUINTA
C/O JEFF.MCQUEEN
8800 N GAINEY CENTER 350
SCOTTSDALE,.AZ 85258
Contractor:'
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760)777-6005
Lic. No.: 672285
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/02/05
-- - - - - -- --------------------------------------
----------------------------------
--
LICENSED CONTRACTOR'S DECLARATION
WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury that•I am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License CI ss: B icense No.: 672285
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
/ate: t ontractor:
issued. '
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier NTL -UNION. INS Policy Number 6436568
following reason (Sec. 7031.5,. Business and Professions Code:' Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
.person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I should become subject to the workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
3700 of t>Lpor Code; I shall forthwith comply ith those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
C
0
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
ete: pplicant: 6 �J
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
�]
'
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNI G: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon„
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND -
and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
_
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
.pursuant to the Contractors' State License Law.). ,
( I I am exempt under Sec. , B.&P.C. for this reason '
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: -
LQPERMIT
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. '
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to. any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 160 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that the above information is correct. I e to comply with all
city and county ordinances and state laws relating to building construction, and hero ut rize representatives
of this couryy 16 enter upon the above-mentioned propertyfo ection purposes
ate:AWkf� gnature (Applicant or Agent):
AV
Application Number.
05-00003374
Structure -Information
Construction Type
TYPE V - NON RATED
Occupancy TypeDWELLG/LODGING/LONG
<=10
Flood Zone . .
. NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION
2001
#_.BEDROOMS
3.00
FIRE SPRINKLERS
NO
GARAGE SQ FTG
576.00.
PATIO SQ FTG
177.00
NUMBER OF UNITS
10.OQ
1ST FLOOR 'SQUARE FOOTAGE
1688.00
Permit" . . .. .
BUILDING PERMIT
Additional desc
Permit Fee
818.00 Plan Check Fee
531.70
Issue Date . . .
Valuation . .
. . 150034
Expiration Date
1/29/06
Qty Unit Charge
Per
Extension
BASE ;FEE
639.50
51-.00 3.5000
THOU BLDG 100,001-500,000
178.50
Permit
MECHANICAL
Additional desc .
Permit Fee . . . .
64.00 Plan Check Fee
16.00
Issue Date . . . .
Valuation . .
. . . . 0
Expiration Date
1/29/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 9.0000
EA MECH FURNACE <=100K
18.00
2.00 9.0000
EA MECH B/C <=3HP/100K BTU
18.00
1.00 6.5000
EA MECH VENT FAN
6.50
1.00 6.5000
-----------------------------------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit.
ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee
85.60 Plan Check Fee
21.40
Issue Date
Valuation
0
Expiration Date
1/29/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1688.00 .'0350
ELEC NEW RES - 1 OR`2 FAMILY 59.08
WPERMrr
Application'Number . . . . 05-00003374
Permit. .
. . . . ELEC-NEW RESIDENTIAL
Qty
Unit Charge. Per
Extension .
576..00
.0200 ELEC GARAGE OR NON-RESIDENTIAL
11.52
Permit
. . . .PLUMBING'
Additional
desc..
Permit Fee.
128.25. Plan Check Fee
32.06
Issue Date
Valuation
0.
Expiration
Date". 1/29/06
Qty
Unit Charge Per
Extension
BASE FEE
15.00
10.00
6.0000 EA PLB FIXTURE
60.00
1.00
15.0000 EA PLB BUILDING SEWER
15.00
1.00
7.5000 EA PLB WATER HEATER/VENT
7.50
1..00
3.0000 EA PLB WATER INST/ALT/REP
3.'00
1.00
9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00 .
5.00
.7500 EA PLB GAS PIPE >=5
3•.75
1.00
-----------------------------------------------------------------------------
15.0000 EA PLB GAS METER
15.00
Permit
. . . GRADING PERMIT
Additional
desc .
Permit Fee
. . . . 15.00 Plan Check Fee
.00•
Issue Date
Valuation
0
'Expiration
Date 1/29/06
Qty
Unit Charge Per
Extension
BASE FEE
15.00.
------
Special Notes
and Comments
SFD -. LOT
38, Plan 4520A.1688 SF/-
BOX BAY,Q
MASTER (26SF) & 4' EXT. GARAGE
(88SF).PERMIT.DOES NOT INCLUDE POOL,
SPA, BLOCK
WALLS OR DRIVEWAY APPROACH
Other Fees
. . . . . . . .. . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00''
DIF CIVIC CENTER - RES
366.00 -
ENERGY REVIEW_FEE
53.17
DIF FIRE PROTECTIQN-RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
15.00
LQPERMIT
" Application Number
:. . . . .
05-00003374
--- - - - - - - - - - - - ------ -- -
Other Fees. .
- - - - - --- - -
. . . . .
- - --
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary.
----------
Charged
Paid Credited
Due
Permit Fee Total
1110.85
.00 .00
1110:85
Plan Check Total
601.16
00 .00
601.16
Other Fee Total ..
2473,17
.00 .00
2473.17
Grand Total
4185:18
.00 .00
4185.18
.Y
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION ••REPORT Date.
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
�✓ IBC
Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor: Architect: Structural Engineer:
Shea Homes Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Jack Machine Calibration:* Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
yr>ppsi to 33.04 kips/33,000 lbs
Calibration Date: Machine #:�--
Phase iA$Lot# L4 b38 Product_%. Plan tiAS-AA N (s0 —9y.
Weather:
CN
�U n6k-A n
Unresolved Items:
None
❑ See Below
Description of Work Inspected: Actual Elongation (in)
Specified Complies within 7% +/- of specified elongation.
Lot # Location Tendons Elongation (in) Reference 11 h/SN2.
(-
Yes No
�
i"10 r0. . Q_sC\ecostoff
(o -ice
3
❑
GIC e a\ Vim.
PkA _L
31
❑
�J o4, -cza_o,
L4
3
0' ❑
21 El
❑ ❑
❑ ❑
❑ ❑
❑ ❑
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications applicable building laws. Final report issued at project completion.
Inspector: Jack C. Millin ICC Certification No 0 42216-89
\a., � 4 - Q_' , ��.
Contractotr's Representative: J " __ - 1 3
i . . I ,.
Copy 1 JCM Inspections Copy 2 Project Superintendent ,!Copy 3 Go veming.Agency----- ---7 Page I of
Y �
rte
jCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-346-5554 - Fax: 760-772-3895 INSF
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
IBC
E] Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta,' LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Slump (inches): ('.'00. Supplier: Superior
TimeSampled: cl, eel Mix Design: D83625P
Time*in Mixer (min.):Specified Strength (PSI): 4000
!4 0
Water Added @ Jobsite (gals.): < Addmixture: POZZ 322N
Concrete Temperature (F): Truck #: L 90 Ticket #: 'I
Ambient Air Temperature (F): 9 0 Field ID Marking: Set A - 4 cylinders
Weather:
Unresolved Items:
E] None
See Below
Location of Sample:—Sl c Cs cc, k, Mc, �.
EJ No Samples Taken
Product Plan
Description of Work Inspected: Phase Lot# 1–/ SA� 0
r\ A,
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional
rebar placed as perthese details and as noted on A A I'Q t!r%o Ci f -e%
Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely,tied and supported off the earth. Accepted for concrete placement.
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab. on Grade. Total cubic yards placed: approx
.A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed'@ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of h.iy ability I have found this work to comply with the approved
plans, specifications -applicable building laws. Final report issued at project completion.
Inspector: Jac C. ICC Certification N`: C842216-80
Contractoes Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent
Copy 3 Governing AgencyI Pige of
`DE6113,2005 10:51 BCI*TESTING,ri1 000-000-00000
- Page 10
CaIC.ERTS Certified Rating ' 0ecember, 13 2005
This Compliance rating is for the home located at:
60945 1 iving Stonp Drivp
'
Conditioned Floor Area:
La Quinta CA, 92253
Certificate Number:
CC3-1798353473
Front Orientation:
Date Inspected:
December, 8 2005
1
CaICERTS Rater:
William Henson
N/A
(:(1004076
HERS Analyst:
N/A
Builder/Developer:
Shea Homes, Tnc..
Project:
Trilogy (al La Quinta
Phase:
Phase 1713
a
Plan Name:
4520
Lot Number:
Specifics about this home:
General Information
'
Conditioned Floor Area:
1650 Square Feel
Conditioned Volume:
U (:ubic Feet
Front Orientation:
N/A
Number of Stories: •
1
Heating and Cooling Systems
Heating Equipment:
Cooling Equipment:
HVA(: Air Distribution
Duct Location:
Duct Leakage Target:
Dud Insulation R -Value:
Air Infiltratinn
Blower Door Target:
Furnace: 0.8
AC: 12
s .
Attic
S.0
6
a
Water I leating System Pro osed
TY I Size I Fuel I EF Distribution
Waiter Hedtifi ' S stern Actual
TY I size I Fuel I EF Distribution
Testina Results
Main System HVAC astern
Area
ested Duct Leakage-,
Yes- Passed
easted TXV:
Yes • Passed
ested Duct Design Compliance:
N/A
ested Duct in Conditioned Space:
N/A
ested Reduced Duct Surface Area:
N/A
ested Infiltration Reduction Credit:
N/A
Ruildina rnvelone
Surface
Area
Pro osed
Actual
R
Value
U
I Factor
R
I Value
U
Factor
Windows
TESTED VAGL 1 car 2)
=APPROVED AS PART OF SAMPLE GROUP
FIRM: BCi T;—::
ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I
PALM DESEERT, CA. 92211
PHONE: 760472-2954
44 /vl
CER t TURLE DTE
the energy efficiency rating of this home is determined using California Home Energy Rating System (C•iICRS) rules. The rating considers
healrny, cooling and water healing and dssurnes average weatlier, lhewiOstat settings, and quantities of hot water for a typical household.
Actual anergy use Will vary arrordinq to occupant behavior. This Rating Completion Summary is provided only after the features listed have
been verified and approved by the CaICFRT5 Certified Rater shown above. If you have a concern or complaint regarding this report Of tho
serViCeS USP4 ill agtainrnq It, you may contact: C:alCkltl s - Customer Service N.U. tyox 6600, Folsom, CA 9S/69.
Pro osed
Actual
Orientation
Area
5H6C
U
Value
SHGC
U
Value
TESTED VAGL 1 car 2)
=APPROVED AS PART OF SAMPLE GROUP
FIRM: BCi T;—::
ADDRES 77-760 COUNTRY CLUB DRIVE, SUITE I
PALM DESEERT, CA. 92211
PHONE: 760472-2954
44 /vl
CER t TURLE DTE
the energy efficiency rating of this home is determined using California Home Energy Rating System (C•iICRS) rules. The rating considers
healrny, cooling and water healing and dssurnes average weatlier, lhewiOstat settings, and quantities of hot water for a typical household.
Actual anergy use Will vary arrordinq to occupant behavior. This Rating Completion Summary is provided only after the features listed have
been verified and approved by the CaICFRT5 Certified Rater shown above. If you have a concern or complaint regarding this report Of tho
serViCeS USP4 ill agtainrnq It, you may contact: C:alCkltl s - Customer Service N.U. tyox 6600, Folsom, CA 9S/69.