SFD (05-3378)60950 Living Stone Dr
05-3378
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
L05-00003378-- _1
60950 LIVING STONE DR'
764-270-999-118 -300234-
DWELLING SINGLE FAMILY
MEDIUM HIGH DENSITY RES
187396.
T,d4t 4
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
SHEA LA QUINTA
C/O JEFF MCQUEEN
DETACHED. 8800 N GAINEY CENTER 350
SCOTTSDALE, AZ 85258
1._rc tect or Engi
s
AUG 102005
- r
UM
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License CI License No.: 672285
ate: ntractor:
111_OWNER-BUILDER DECLARATION '
I hereby affi under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with'wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or. herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If,'however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec:
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I _ 1 I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Contractor:
SHEA.HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760)777-6005
Lic. No.:.672285
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 177-7153
Date:" 8/02/05
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintairi a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the. work for which this permit is
_)��// issued.
V have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier NTL UNION INS Policy Number 6436568
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
nd agree that, if I should become subject to the workers' compensation provisions of Section
700 the Labor Code, I shall forthwith comply ith those provisions.
rhe: plicant: W S
WARNI G: AILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT A EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UPTO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a.permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission.related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days 'from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and cou ty ordinances and state laws relating to building construction, and her thorize representatives
of this cou y enter upon the above-mentioned property spection purpos
Dote: nature (Applicant or Agent):
LQPERMIT
_ Application Number .
. . . 05-00003378
Structure Information
Construction Type
TYPE V - NON RATED, .
Occupancy Type . . .
. . DWELLG/LODGING/LONG <=10
Flood Zone . .
. . . NON -AO FLOOD ZONE
_ ..Other struct info
CODE EDITION 2001 CBC
FIRE•SPRINKLERS NO
.
GARAGE SQ FTG
478.00
PATIO SQ FTG ..
_,178.00
NUMBER OF UNITS
1:00:
-------------------------------------------------------------------
1ST FLOOR -SQUARE FOOTAGE
2174.00:
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . . .
926.50 Plan Check Fee
602.23
Issue Date
Valuation
181091
Expiration Date
1/29/06
Qty Unit Charge
Per
Extension
BASE FEE
639.50
.82.00 3.5000
----------------------------------------------------------------------
THOU BLDG 100,001-500,000
287.00
Permit . . .
MECHANICAL
Additional desc .
Permit"Fee
77.00 Plan Check Fee
21.63
Issue Date
Valuation
0
Expiration Date
1/29/06
Qty Unit Charge
Per`
Extension
BASE FEE
15.00
2.00 9.0000
EA MECH FURNACE <=100K
18.00
- .00. 11.0000
EA MECH FURNACE >100K
.00
2.00 .9.0000
EA MECH B/C <=3HP/100K BTU
18.00
.00 16.5000
EA MECH B/C >3-15HP/>100K-500KBTU
.00
3.00 6.5000
EA MECH VENT FAN
19.50
1.00 6.5000
EA MECH EXHAUST HOOD
6.50
Permit
ELEC-NEW RESIDENTIAL
" Additional desc .
Permit Fee . . . .
100.65 Plan Check Fee
3.77
Issue' Date . . . ..
Valuation . . . .
0,
' Expiration Date
1/29/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
LQPERMIT
Application.Number . . . . . 05-00003378
Permit . . . . ELEC-NEW RESIDENTIAL
Qty .Unit Charge Per
Extension
2174.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY
76.09'
478.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL
9.56
Permit PLUMBING
Additional desc .
Permit Fee . . . . 138.00 Plan Check Fee
34.50' '
Issue Date Valuation
0
Expiration Date 1/29/06
Qty Unit Charge Per.
Extension
BASE FEE
15.00
12.00 6.0000 EA PLB FIXTURE
72.00
1.00 15.0000 EA PLB BUILDING SEWER
15.00
. 1.00 7'.5000 EA PLB WATER HEATER/VENT
7.50
1.00 9..0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
6.00. .7500 EA PLB GAS PIPE >=5
4.50
1.00 15.0000 EA PLB GAS METER
15.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee . . . . 15'.00 Plan Check Fee
.00
Issue Date Valuation . . . .
0
Expiration Date 1/29/06
Qty Unit Charge Per
Extension
BASE FEE
15.00
-----------------------------------------------'-----------------------------
Special Notes and Comments
SFD LOT 118 PLAN 5515C, 2174,.SF,
INCLUDES
26 SF BOX BAY @ MBR & 26 SF BOX BAY @
NOOK. PERMIT DOES NOT INCLUDE'BLOCK -,
WALL, POOL, SPA OR DRIVEWAY APPROACH.
Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE.
60.22
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00•
- DIF PARKS/REC - RES
502.00
LQPERMIT. - -
- -
Application"Number
. .
05-00003378
-- -• - - - - - - - - - -- -
Other Fees
- - -
STRONG MOTION (SMI) - RES
18.73
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary.
Charged
Paid Credited
Due
Permit Fee Total
1257.15
.00 .00.
1257.15
Plan Check Total
662.13
.00 .00
662.13
Other Fee Total
2483.95
.0.0 .00
2483.95
Grand Total
4403.23
.00 .00
4403.23
•- PREPARED 3/16/11,
10:22:03
-
INSPECTION
HISTORY REPORT
PAGE 1
} .PROGRAM
BP521L
0/00/00
THRU 0/00/00
_
-
-
- -
• CITY OF
LA QUINTA'
----------------------''
--------------------------------------------------------^-------------------------------------------
' APPLICATION
PROPERTY ADDRESS
APN
Alternate ID
..
STRUCTR
PERMIT
INSPECTION
RESULT DATE/STATUS
INSPECTOR '
• 05 00003378-
60950
LIVING STONE DR -
764-270-999-118
-300234-
300234-000'000
000
000
B001
00
BUILDING PERMIT
120.'0001
FOOTINGS
9/07/05
APPROVED
GH
000
000
B001
00
BUILDING PERMIT
125
0.001 SLAB
9/07/05
APPROVED
GH
- '.0 -00
000
B001
00
BUILDING PERMIT
.135
0001 ROOF NAIL
10/07/05
APPROVED'
-GH
" ...000
000
BOOL
00
BUILDING PERMIT
- .140
0001 OKAY TO WRAP
10/19/05
APPROVED
GH • _ -
'. 000
000
B001
06
BUILDING PERMIT
145
,0001 FRAMING.
10/25/05'APPROVED
-
GH
. 000
000.
B001
00
BUILDING.PERMIT
150
0001 INSULATION
10/27/05
APPROVED -
.GH,
- 000
000
:B001
00
BUILDING PERMIT
155
00,01 LATH -
11/01/05
APPROVED
GH '-
000
000
B001
00
BUILDING PERMIT
160
0001 DRYWALL NAIL
11/01/05
APPROVED
GH - - -
000
000
B001
00
BUILDING-PERMIT ",
900
0001.COMMUNITY DEVELOPMENT
FIN' 1/10/06
APPROVED
..GH ,
000
000
B001'00
BUILDING PERMIT
910
0001 PUBLIC WORKS FINAL
•1/10/06
APPROVED
GH ..• ,.
000
000
B001
00
.BUILDING PERMIT.
` 199
0001 FINAL -
1/10/06'-APPROVED
GHI - ..
000.000
E01
00
ELEC-NEW RESIDENTIAL
310
0001 ROUGH ELECTRICAL'„ ..
10/25/05
APPROVED - -
GH
. 000
000
E01
00
ELEC-NEW RESIDENTIAL-
315.
0001 TEMP USE OF. PERMANENTPOW
12/01/05
APPROVED
GH ..
000
000
E01'
00
ELEC-NEW RESIDENTIAL
399
0001*. ELECTRICAL FINAL-
1/10/06
APPROVED
- GH ..
000
000
GP
00
GRADING PERMIT -
197
0001 GRADING FINAL
1/10/06
APPROVED .-
GH - -
000
000
M01
00
MECHANICAL
405
0001 ROUGH MECHANICAL
10/25/05
APPROVED
GH
' - 000
000
M01
00.
MECHANICAL
499
0001 MECHANICAL FINAL
1/10/06
APPROVED '-
GH - -
- .000'000
P01.
00
PLUMBING -
210
0001-SEWER CONNECTION ,
8/26/05
APPROVED
GH. _ ..
000
000.
P01
00
PLUMBING
200
0001 UNDERGROUND•.PLUMBING
8/26/05'APPROVED
GH
' 000
000
P01
00
PLUMBING
230
0001 ROUGH PLUMBING
10/25/05
APPROVED
GH - - -
000
000
P01
00
PLUMBING
- 245
.0001 SHOWER PAN
10/25/05
APPROVED
GH
' 000
000
P01
00
PLUMBING
235
0001 GAS LINE./ GAS TEST
•11/16/05
APPROVED-
.GH ..
' - 000.000
P01
00
PLUMBING
299
0001 PLUMBING FINAL
1/10/06
APPROVED
GH
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS
Phone: 760-345-5554.- Fax: 760-772-3895 • INSPECTIONS
COMPRESSION STRENGTH TEST. RESULTS
Client: Shea La Quinta, LLC Date: .11/29/05
Project: Trilogy @ La Quirita -Shea Homes -'Project No: -0261.109
'81-260 Avenue 62. .
La Quinta, CA 92274
Set ID. Structure Age of Test Compression Strength
JCM ID Location Date Cast Cylinder ID (days) (psi)
Set A Phase 12B - Lot # 4118 .Slab on Grade. 9-7-05 Concrete
273-597/ Great Room !! Required psi: 4000
O -41 67i1_-> L J-/) 1206 7 2650
O 1207 28 3700,
lam- A�� �� Z. Z 5✓ 1208 28 3750
'1209 56' 4000
1 JCM Inspections
39725 Garand Lane Suite F `
Palm Desert, CA 92211
-I
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
I N S P E C'T I.O.N S
PRESTRESSED CONCRETE INSPECTION REPORT
'Date: q = 14 -cam
Project Name:
Project No:
Trilogy @ La Quinta -Shea Homes
02-1109
Project Address:. , 'City:
�✓ 16C
81-260 Avenue 62 La Quinta,
CA
E] Title 24
Client: Sub-Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
Other:
General Contractor: Architect:
Structural Engineer:
Shea Homes Bassenian Lagoni
Borm & Assoc,lnc/Suncoast Post Tension LP
Weather:
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress-Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast-Gage Pressure in psi to Machine Load in kips
Unresolved. Items:..
S -JCo psi to 33.04 kips/33,000 lbs
None
❑ See Below
Calibration Date: Machine # � ,). y Q, 3 (- cm;
PhaseLot# LAI 100 Product ,-.I., Plan S;SJSC. to-
�:
Description of Work Inspected:
Actual Elongation (in).
Specified . Complies within 7% +/- of specified elongation.
Lot # Location' Tendons Elongation (in)
Reference 11 h/SN2.'
}.
+t—
No
l a rO.ctCZ.: R—em
t)
I
LJ
❑
Crim c rQ�a��I b ..Wi w1 _& In
I
119-
Er
❑
Elems.
4a--
s
�-
El
❑
❑
❑
❑
❑
❑
I hereby certify that I have-inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply,with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
'+
Inspector: Jack C.,Millin, ICC Certi I tion No:0842216-89
Contractors Representative
Copy 1 'JCM Inspections ' Copy 2 Project superintendent Copy/3 Governing Agency_ ge ,� of
JCM Inspections
39725 Garand Lane.Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
Q✓ IBC
Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults. Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Slump (inches): 'Supplier: Superior
Time Sampled: ',ad Ckv�, Mix Design: D83625P
Time.in Mixer (min.): L4y4Z- Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): Addmixture: POZZ 322N .
Concrete Temperature (F): $ 5 Truck #: y [4,Ticket #: 09
Ambient Air Temperature (F): �� , Field ID Marking: Set A - 4 cylinders
Weather:
Unresolved Items:
None
❑ See Below
Location of Sample:. S� a\� a G( 01k Cl- GC r` a
❑ No Samples Taken
Description of Work Inspected: Phase Lot# (..� O Product Plan(On5 G
O -9-C 2b L1 v i nell
- ck - 0
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical In Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings
tand`a(Vis,__ rebar placed as per these details and as noted on S' 3 , r `` b p y� Q c,„u V11, rk fi UJ 5 C��->`F �} Lam..
Also, typical details 2, 3/SD-1 and Notes on SNA apply. ,Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: appro ,.
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx ` Verified correct mix design.
I hereby certify that I have inspected all of the above work; unless otherwise noted, and to the best of my, ability.I have found this work to comply with the approved
plans, specifications _applicable building'laws. Final report issued at project completion.
Inspector: Jac C. Millin I((C��C Certificatio o: 0842216-80
R A 1: • �r ►..�
Contractor's Representative �.
/•!, .ref~
Copy 1 JCM Inspections Copy Project SuperintendentCopy 3 Governing Agency Page of
-DEC*20,2005 19:22 BCI*TESTING,ri1 000-000-00000
W
CaICERTS Certified Rating
Page 6
December, 20 2005
This Compliance rating is for the home located at:
60950 Living Stone Drive
La Quinta CA, 92253
Certificate Number: CC3-1798353905
I
Date Inspected: December, 19 2005
U ,
I Factor
CaICERTS Rater: William Henson
�Wc
CC2004076
N/A
HERS Analyst: N/A
E
Builder/ Developer; Shea Homes, Inc.
R
Project: Trilogy @ La Quinta
T
Phase: Phase 12B
S._
Plan Name: 551-5—
Lot Number;118�
Specifics about this home:
General Information
Conditioned Floor Area: 2100 Square Feet
Conditioned Volume: 0 Cubic Feet
Front Orientation: N/A
Number of Stories: i
Building Envelope
urface
i
Area
Proposed
Actual
R
Value
U
I Factor
R
Value
U ,
I Factor
Heating and Cooling Systems Windows
Heating Equipment: Furnace: 0.8 Proposed Actual
Cooling Equipment: AC: 12 Orientation Area SHGC Value SHGC Value
HVAC Air Distribution
Duct Location: Attic
Duct Leakage Target: 6.0
Duct Insulation R -value: 6
Air Infiltration
Blower Door Target: 120
Water Heating System Pro osed
TY I Size I Fuel I EF Distribution
Water Heating System Actual
TY I Size I Fuel I EF Distribution
Testina Results
n S stem HVAC 5 stem
ted Duct Leaka e:
Yes - Passed
ted TXV:
r
Yes - Passed
ted Duct Desi n Com liance:
N A
ted Duct in Conditioned Spaced
N A
acted Reduced Duct Surface Area:
N/A
lasted Infiltration Reduction Credit:
N/A
TESTED (PAGE 1 OF 1)
=APPROVED AS PART OF SAMPLE GROUP
FIRM: BCI TESTING
ADDRES 77.760 COUNTRY CLUB DRIVE, SUITE I
PALM DESEERT, CA. 92211
PHONE: 7GO.772-2966
Lf—
/t:LRTI YING IG RE DATE
The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers
heating, cooling and water hoating and assumes average weather, thermostat settings, and quantities of hot water for a typical household.
Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have
been. verified and approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the
services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763.