Loading...
SFD (05-5443)Application. Number. 0500005443 Property Address: 61105 Living Stone Dr 05-5443 APN: 764-270-999-46 -300234- Application description: DWELLING SINGLE FAMILY Property Zoning: MEDIUM HIGH DENSITY RES Application valuation: 142817 Applicant: Architect or Engir 12.04, BUILDING & SAFETY DEPARTMENT h CIV C �V O DING PERMIT LICENSED CONTRACTOR'S DECLARATION " I hereby affirm under penalty of perjury hat I am licensed under provisions of Chapter 9 (commencing with Section 000) ol Division 3 of th 'n ss and Profess, nals Code, and my License is in full farce and effect. U n ess: Li ense No.: 672285 Dat: [� Contractor. t - OWNER -BUILDER DECLARATION I hereby affirm under.penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code:. The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, _ -and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply, to an owner of _ property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. B.&P.C. for this reason Date: - Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012. FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: .12/14/05 Owner:. SHEA LA QUINTA C/O JEFF MCQUEEN 8800.N GAINEY CENTER 350 SCOTTSDALE, AZ 85258 Contractor: SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA, CA 92253 (760)777-6005 Lic. No.: 672285 ------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AMERICAN HOME Policy Number 1247619 _. I certify that, in the performance of the ark for which this permit is issued, I shall not employ any person in any manners as to becom subject to the workers' compensation laws of California, and agree that, if I s ul ecome su ect to the workers' compensation provisions of Section 700 of the Labor shall fo I with those provisions. Da Applican . WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under "or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days' from date of issuance of such permit, or cessation -of work for 180 days will subject permit to cancellation. - I certify that 1 have read this application and state that the ove information ' correct. I agree to comply with all city and coun ordinan es and state laws relating to buildi struction thorize representatives of thi my r on the above-mentioned propert or in a pur es. r Date: ture (Applicant or Age Application Number 05700005443 Structure"Information Construction Type . ., . . TYPE V - NON RATED Occupancy Type DWELLG/LODGING/CONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info.. . . . CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 562.00 PATIO.SQ_FTG 457.00.' NUMBER OF UNITS` 1.00 ------------------------------------------------------------------- 1ST FLOOR SQUARE"FOOTAGE. 1556.00 Permit . . BUILDING PERMIT Additional desc..' ` Permit Fee 790.00 Plan Check Fee 513.50 Issue Date . . . . Valuation . . . . 142817 Expiration Date 6/12/06 Qty Unit Charge Per Extension BASE FEE 6.39.50 43.00' 3.5000 -THOU BLDG 100,001-500,000 150.50 Permit . . . MECHANICAL Additional desc . Permit -Fee 77.00 Plan Check Fee 19.25 Issue Date Valuation 0 v Expiration Date- 6/12/06 Qty Unit Charge Per Extension. BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000,EA MECH B/C <=3HP/100K BTU 18.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . ELEC=NEW RESIDENTIAL 1" " Additional desc . Permit,Fee. 80.70 Plan Check "Fee,:' 20.18 .Issue'Date Valuation 0 Expiration Date . Qty Unit Charge. Per Extension' BASE FEE 15.00 1556.00 .0"350 ELEC NEW RES - 1 OR 2 FAMILY 54.46. 562.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.24 LQPERMIT Application Number_ . . . 05-00005443 Permit PLUMBING Additional desc . Permit. Fee .123.00 Plan Check Fee 30.75 Issue Date -Valuation 0 Expiration Date 6/12/06. Qty: Unit Charge. Per Extension BASE FEE 15.00 9.00 6.0000 EA PLB.FIXTURE 54.00- 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 .6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00" 15.0000 EA PLB GAS METER 15.00 Permit . . GRADING PERMIT Additional desc,. Permit Fee 15•.00 Plan* Check Fee .00 Issue Date Valuation 0 Expiration Date '6/12/06 Qty Unit Charge Per Extension "BASE FEE 15.00 ------------------------------------------------------------------------------ Special Notes and.Comments SFD - LOT 46 PLAN 4510A, 1556 SF (26 SF BOX BAY @MBR, 83 SF GAR. EXT. 120/SF PATIO EXT.PERMIT DOES NOT INCLUDE BLOCK WALLS., POOL, SPA OR DRIVEWAY APPROACH Other Fees ART IN'PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 51:35 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES. 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC.- RES 892.00 STRONG MOTION (SMI) - RES 14.28 DIF -STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION --RES 1666.00 Fee summary Charged Paid.' Credited Due iQPE „ Application Number . . . . 05-00005443 - - Permit Fee Total ----- 1085.70 ---- --- --- .0.0 00 ------ -- 1085.70. Plan Check Total 583.68'. .00 .00 583.68 Other Fee Total 3761.63 .00 .00" 3761.63 Grand Total 5431.01 .00 .00 5431.01 ,r LQPERMIT - - JCM Inspections 39725 Garand Lane Suite F IL Palm Desert, CA 92211 i I N S P E C.T IO N S Phone: 760-345=5554 - Fax: 760-772-3895 ` i INS PEC T I ON 5. F k COMPRESSION STRENGTH TEST RESULTS,* ' Client: Shea La Quinta, LLC Date .3/13/06 - �-dam .. .. . .:' . .♦ . ., � `' ♦` � .. .. _t w• 1 r. -,Pr @'L'a Quinta'-Shea Homes ` F` Project No `02-1109 ^��81-260 Avenue 62 r. ;, ♦ i : w; f, " La Quinta, CA 92274 Set ID Structure •, _ Age of Test Compression Strength JCM ID Location ,' L , ' Date Cast • Cylinder ID (days) ,(psi) Set A Phase 13C - Lot # 4046 Slab on Grade 2-7-06 Concrete ! 273-667 Bedroom 2 /_�C �5 / . � i""� �� " r Required psi: 4000 2657 .7 - 3870 " -• 2658 28. 5250 2659. _ 28 L 5310 CERTIFIED:. nspections supplies the service a f �,; 3 -.. ; , t . • of compression strength test results only. Per ASTMC39 1f:'• ., • :w [ - r .tet, y' - -' - +x 04 0 Page 1 of 1 "� �} a:• A a '? f �, . , JCM Inspections ' 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - .Fax: 760-772-3895 I N S P E C T I o N s REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 •• La Quinta, CA ❑✓ IBC E] Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagohi Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): Supplier: Superior Time Sampled: n c,.,%"% Mix Design: D83625P' Time in Mixer (min.): J f i Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): Al Addmixture: . POZZ 322N Concrete Temperature (F): Truck M ���, Ticket#: / Ambient Air Temperature (F): in�� Field ID Marking: Set A -'4 cylinders Weather: Unresolved Items: ® None ❑'See Below Location of Sample: a� n , J n �Q . e,>`!rnnV,Il �. No Samples Taken Description of Work Inspected: Phase 3C_ Lot# O L`(Product PlanL L't i, e, C��l o A Q, 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on £ , , nLA o (' a n CC Q xe� r, I r A J en Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. • Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total,cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders, for compression tests with breaks at 7 days (1), 28 days (2) and.one for holding purposes. 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. +. . Inspector: Jack C. Millin ICC Certific tl ' O.. 0842216-80 Co1ntractoes Representative; Copy 1 JCM Inspections . Copy 2 Project Superintendent + Copy 3 Governing Agency Page A— of + JCM Inspections 39725 Garand Lane Suite F I_ Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION. REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: OIBC 81-260 Avenue. 62 La Quinta, CA ❑ Title 24 Client: Sub -Contractor: Shea La Quinta,,LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Size and Type of Tendons: 1/2"'Diameter Seven Strand Stress -Relieved Tendons Weather: SUAt,u. Jack Machine, Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips Unresolved -It ms: S3,0ca psi to 33.04 kips/33,000 lbs None E] see Below Calibration Date: Machine # Phase GC Lot# L4duct Plan y �� Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +1- of specified elongation. Lot Location Tendons Elongation (in) Reference 11 h/SN2. 1# y a"1 Yes No n c c1 c. _CEJ` �1 � t\ 1 0 I 3�L �� ❑ Q� S]� n o.�J—SitIlS.. S � � 1�1i ❑ / QSt I t 7 ED- El nn -Aj El ❑ ❑ ❑ ❑ ❑ ❑ ❑ . ❑l ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No: 0842216-89 Contractor's %Representatitive: (A ! Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of � MAY 17,2006 12:55 BCI*TESTING,ri1 000-000-00000 Page 3 CF -4R CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING May, 15 2006 This CF -4R issued by CaICERTS® is for the home located at: 61105 Living Stone Drive La Quinta CA, 92253 Certificate Number: CC3-1798363684 w)t{ Date inspected: May, 15 2006 CaICERTS Rater; William Henson 1573 Square Feet CC7.004076 ` HERS Analyst: Chinh Nguyen r: Builder/ Developer: Shea Homes, Inc. 1� Project: -Trilogy 2005 Standards Phase: 13C Plan Name: 4510 STD Lot Number: 046 . Specifics about this home: General Information Conditioned Floor Area: 1573 Square Feet Conditioned Volume: 14157 Cubic Feet Front Orientation: Cardinal Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment; ACSplit: 13.0 HVAC Air Distribution Duct Location: ALLIc: Duct Leakage Target: 0 Duct Insulation R -Value: 6.0 Air Infiltration Blower Door Target: Water Heatino System Proposed TY Size Fuel EF Distribution 1 50 Gas 0.62 Standard Water Heating System Actual TY Size I Fuel I EF Distribution 1 50 Gas 1 0.62 1 Standard Testing & Verification Results Main System HVAC 5 Stem 'Duct Scaling Passed Installation of Thermostatic. I Expansion Valve Passed TXV High Energy Efficient Ratio EER Passed Teated QApproved Aa Part Of Sample ()roup $ CI Testing 77-760 Country Club Bttite I Palm Desert, CA, 92211 M-772-29, _> =/S - Certifying Signature Date The energy efficiency rating of this hone Is deter'rnirled using California Home Energy Rating System (C -HERS) rUles. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings; and Quantities, of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided unly after the features listed have been verified and approved by tite CaICERTS Certified Rater shown above. If you haves a turners or complaint regarding this report of the services used in obtaining it, you may contact: CaICFRTS - Customer Service 11 Natoma St Suite 140, Folsom, CA 95630. INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 61-105 LIVING STONE DRIVE, LOT 4046, PHASE 13C, LA QUINTA, CA CEILINGS: TYPE: BLOW MANUFACTURER: Cocoon THICKNESS: R-38 WALLS: TYPE: BATTS MANUFACTURER: Borate THICKNESS: WA3 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAGO SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 BY: TITLE: ACCOUNT REPRESENTIVE DATE: G ::::.:. ,..; .... .:. �.�:.: _. ... .:.:.:,.,. ..... �� • .:,.:.. , . ::tel. .. .: r..... �.. .,•. ._..<....... . .... .. .. ......». ._ ..... .. ZT/60 39dd 6TBTOP609LI Sb:TZ 7'000b0/T0 ~—