SFD (05-5445)Application Number: 05-0000544
Property Address: 61125 Living Stone Dr
05-5445
APN: 764.-270-999-47. -300234-
Application description:.
DWELLING - SINGLE FAMILY
Property Zoning:
MEDIUM HIGH DENSITY RES
Application valuation:
149689
(W-,4 4u�r
VOICE. (760).777-7012
FAX (760) 777-7011
BUILD FETY DEPARTMENT INSPECTIONS (760) 777-7153
/ DI G •PERMIT
Date: 12/14/05
rs �� Owner:
SHEA LA QUINTA
�y C/O JEFF MCQUEEN
TACHE 0c)�' 8800 N GAINEY CENTER 350
C.- O 9 SCOTTSDALE, AZ 85258
Applicant:rc/A hitect or Engineer:
�Sk�C6A S
------------------
LICENSED CONTRACTOR'S DECLARATION
6 v�
Contractor:.
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760)777-6005
Lic. No.: 672285
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 -(commencing with
Section 7000) of Qivision 3 of the Busin ss and Professionals Code, and my License is in full force and effect.
Licens CI B enseNo.: 672285
Date:-ontractor:�,I,
.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that.I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the.
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business -and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or'improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of. sale.).
1 _) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I—) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner: .
CONSTRUCTION LENDING AGENCY '
-I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.). '
Lender's Name: Q�
Lender's Address: ' `
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work -for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier AMERICAN HOME Policy Number A 1247619.
_ I certify that, in the performance of the work for ich this permit is issued, I shall not employ any ,
person in any manner so as to b me subject the workers' compensation laws of California,
and agree that, if I should ec a subject tot a workers' compensation provisions of Section
j37�of Labor Code, f hwith' se.provisions.
e: ant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
-DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. '
1.. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta,' its officers, agents and employees for any act or omission related to the work being .
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to caricellation. -
1 certify that I have read this application and state that t e ab ve information is correct. I agree to comply with all
city and county ordin1�nc�esatndstate laws relatingto onstructio and hereby authorize representativesoft oun o enuabove-mentioned pr pe r specti oses.atApplicant or Ag '
a.
Application Number ..
. 05-00005445
Permit
BUILDING PERMIT
.
Additional desc .
Permit Fee
814.50Plan
Check Fee ..
132.36
Issue.Date . . . .
- ,.Valuation
149689
Expiration'Date
.6/12/06'
Qty Unit Charge,
Per
Extension
BASE
FEE
639.50
50.00 3.5000
THOU BLDG
100,001-500,000
175.00
Permit . . .
MECHANICAL
Additional desc .
Permit Fee
90.00
Plan Check Fee
5.63"
Issue Date
Valuation . . . .
0
Expiration Date
6/12/06
'.
Qty Unit Charge
Per
Extension.
'
BASE
FEE
15.00..
2.00 9.0000
EA MECH
FURNACE <=100K..
18.00
2.00 9.0000
EA MECH
B/C <=3HP/100K BTU
18.00
.5.00 .6.5000
EA MECH
VENT.FAN
32.50
1.00 6.5000
EA MECH
EXHAUST HOOD
6.50.
Permit
ELEC-NEW RESIDENTIAL
Additional-desc .
Permit Fee . . . ."
83.40
Plan Check Fee
5.21
Issue Date
Valuation . . . .
0
Expiration Date
6/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
15..00
1636.0'0 .0350
ELEC
NEW RES - 1 OR 2 FAMILY•
57.26
557.00 .0200
ELEC
GARAGE OR NON-RESIDENTIAL.
11.14
Permit. ... . . .
PLUMBING
Additional desc
'
Permit Fee . . . .
146-.25
Plan Check Fee ,.
9:14
Issue Date . . . .
Valuation
.0
" Expiration Date'..
6/12/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
13.00 6.0000
EA PLB
FIXTURE
78.00
1.00 15.0000
EA, PLB
BUILDING SEWER
15.00
LQrERMrr
Application Number 05-00005445
Permit . . . . . . PLUMBING..
Qty Unit Charge Per
Extension
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00 .7500 EA PLB GAS PIPE•>=5
T.75
1.00 15.00,00 EA PLB GAS METER
15.00
Permit . .GRADING PERMIT
Additional desc
Permit Fee 15.00 Plan Check Fee
.00
Issue Date . . Valuation
0
Expiration Date 6/12/06
Qty Unit Charge Per
Extension
BASE FEE.
15.00
-----------------------------
:Special Notes and Comments
SFD - Plan 4210B Lot.47, 1636 S.F-.
w/Casita (255sf), MBR Box Bay (26sf),
Ext Garage (83sf) & Ext Patio "(177sf).
Permit does not include block wall,
pool or driveway approach. 75%
REDUCTION TO PLAN CHECK FEES DUE TO
MULTIPLE ISSUANCE OF SAME PLAN TYPE
-- --------------------------
Other Fees • . . . .ART IN PUBLIC PLACES -RES
20.00
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
480.00
ENERGY REVIEW FEE
13.24
-DIF FIRE PROTECTION -RES
140.00
• GRADING PLAN CHECK FEE
.00.
DIF LIBRARIES - RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC.- RES
892.00
STRONG MOTION (SMI) - RES
14.96
DIF STREET MAINT FAC -RES*
67.00
DIF TRANSPORTATION - RES
•1666.00
Fee summary Charged Paid Credited
Due
---------- ----------
Permit Fee Total 1149.15 .00 .00
1149.15
Plan Check Total 152.34 .00 .00
152.34
Other. Fee Total 3744.20 :00 .00
3744.20
' Grand Total 5045.69 .00 .00
5045.69
LQPERMIT
JCM Inspections ,
39725 Garand Lane Suite F
I LJL" Palm Desert, CA 92211
I N S PEC T I O N S Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS i
Client: Shea La Quinta, LLC Date: 3113106
Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109
81-260 Avenue 62
La Quinta, CA 92274, ,
Set ID Structure Age of Test Compression Strength
JCM ID Location Date Cast Cylinder ID (days) (psi)
Set A Phase 13C - Lot # 4047 Slab on Grade 2-7-06 Concrete
273-666 Kitchen Required psi: 4000
2661 7 .3730
w 2662 28 5140
2663 28 5180
CERTIFIED: ,
CM Inspections supplies the service
of compression strength test results only.
T Per ASTMC39
Page 1 of 1
- - ' ray..,., w.... • vi .
- JCM Inspections
39725 Garand Lane'Suite F
Palm Desert, CA 92211
INSPECTIONS. Phone: 760-345-5554 - Fax: 760-772-3895' INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted,Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
.
IBC
�✓
81-260 Avenue 62 La Quinta, CA
Title 24
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
Other:
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Sun* coast Post Tensi
Slump (inches):, c�—� Supplier: Superior
Weather:
Time Sampled: Sb n Mix Design: D83625P
Time in Mixer (min.): Specified Strength (PSI):. 4000
Unresolved Items:
Water Added @ Jobsite (gals.), �1 n n Addmixture: POZZ 322N
Concrete Temperature (F): Truck #: Ticket #:�9
®' None
Ambient Air Temperature (F): y` 1 Field ID Marking: Set A - 4 cylinders
Q See Below
Location of Sample , a\),j a n 't o•& e k T c t -(a rt
No Samples Taken
Description of Work Inspected: Phase Lot# Ir' py Product Plan
—O6 J
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13)SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns�� (6,7,8/SD-1), Pad Footings and additional.
rebar placed as per these details and as noted on �' � t, Q ; /1 "�' a s Com. , l . OT n C.
to li C� W \ t� 1�i7 vJ C. C1 �f+! C�tA( NJ n'1 .
Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
0(0
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx n,
A mechanical vibrator was used to consolidate the.concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
-'Oco
1) The placement of concrete for Garage Interior. Footings and Slab on Grade Total cubic yards placed: approx., verified correct mix design. :.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector:' Jack Millin ICC CerVficatlo o: 0842216-80'
C(tontractoies` Representative:'"" �.
Copy 1 JCM Inspections
0
Copy 2 :Project Superintendent
Copy 3 Goveming Agency Page 4 of
INSPECTIONS'
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTION s
PRESTRESSED CONCRETE INSPECTION REPORT
Date:,=.)_ ►S--O(�
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address:
81-260 Avenue 62
City:
La Quinta, CA
�✓ IBC
Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor:
Shea Homes for Active Adults
Architect: Structural Engineer:
Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
S,30n psi to 33.04 kips/33,000 lbs
Calibration Date: Machine # :37I 1 _Q�
Phase LsGLot# 44 p!-' N7 Product Plano1 I O (�G � U,4 O
Weather:
unnu •
Unresolved Item :
KNone
❑ See Below
Description of Work Inspected:
Lot #.Location
Actual Elongation (in)
Specified Complies within 7% +/- of specified elongation.
Tendons Elongation (in) Reference 11h/SN2.,
�- "1 pL,,,-7
Yes
No
S
I� �
a'
❑
G.- F'C O�-1ti I FSril\;\ --S\.� 1
�
.3�
LJ
❑
, p r
EQ�
El
y qz .C-�-a
3A-
u�-
Ea-
❑
Q� CAOnVI-)
4_
y I
❑
c akrx-S,A-4p—,
Eg-"
❑
❑
❑
❑
❑
❑
❑
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Jack C. Millin ICC Certificatio
IN
C.ca�'
No:0842216-89
—
Contractor's Representative:
�� ,
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3' Governing Agency Page of
,I . MAS 17,2006 12:55 BCI*TESTING,ri1 000-000-00000
Page 2
CF -4R
CERTIFICATE OF FIELD VERIFICATION 8L DIAGNOSTIC TESTING May, 15 2006
This CF -411 Issued by Ca10ERTSO Is for the home located at:
61175 1 iving Stone Drive
Cooling Equipment:
Conditioned Floor Area:
La Quints CA, 97253
Certlifcate Number:
CC3-1798363685
Wr L(0 q -7
Date Inspected:
May, 15 2006
1
CaICERTS Rater:
William Henson
CC70CA076
i
HERS Analyst:
Chinh Nguyen
Expansion Valve
Builder/Developer:
Shea Homes, Inc.
EER
Project:
Trilogy 2005 Standards
Phase:
13C
'
Plan Name:
4210 easit
Lot Number:
047
Specifics about this home:
General Information
Cooling Equipment:
Conditioned Floor Area:
1355 Square Feet
Conditioned Volume:
12295 Cubic Feet
Front Orientation:
Cardinal
Number of Stories:
1
Heating and Cooling Systems
Heating Equipment:
Furnace: 0.8
Cooling Equipment:
ACSplit' 13.0
Heating Equipment:
Furnace. 0.68
Cooling Equipment:
A/C:: 13
HVAC Air Distribution
Duct Location: Attic,
Duct Leakage Target: 0
Duct Insulation R -Value: 6.0
Air Infiltration
Blower Door Target: 0
Water Hedting System Pro used
TY I Size Fuel EF Distribution
1 50 Gas 0.62 Standard
Test/nn R VPrifirah;nn m -craft
Main System HVAC System
Duct Sealing
Passed
Installation of Thermostatic I
TXV
Expansion Valve
passed
High Energy Efficient Ratio
EER
Passed
New System HVAC System
Duct Sealing,Passed
Installation of Thermostatic I
TXV
Expansion Valve
passe
High Energy Efficient Ratio
EER
Passed
® Teeted
Approved As Part Of Sample Group
BCI Testing
77-780 Country ClubOSE is I��
Palm Desert, CA. 92212
760.-772-454
Water Heating System Annual
TY I Size Fuel- EF Distribution Certifying Signature Date
L --L-A 5o Gas 0.62 Standard
The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. 1'he rating considers
heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household.
Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after tilt features listed have
been verifled and 'approved by the CaICERTS Certified Rater shown above. If you have a concern or complaint regarding this report of tire
services used in obtaining it, you may contact: C4ICERTS - Customer Service 11 Natoma St Suite 140, Folsom, CA 95630.
INSULATION CERTIFICATE
This is to certify that insulation has been installed in conformance .with the current energy
regulation, California Administrative Code, Title 24, State of California, in the building at
61-125 LIVING STONE DRIVE, LOT 4047, PHASE 13C,.LA QUINTA, CA
CEILINGS:
TYPE: BLOW MANUFACTURER: Cocoon THICKNESS: R-38
WALLS:
TYPE: BATTS MANUFACTURER: Borate THICKNESS: W-13
GENERAL CONTRACTOR: SHEA HOMES LICENSE #
BY: TITLE:
PARAG N SCHMID B ILDING PRODUCTS A MASCO Company LICENSE # 221517
BY: TITLE: ACCOUNT REPRESENTIVE DATE:
i
J '
T •
ZT/BT 39Vd R' -6T8T0V609LT 9b:TZ, ;Z00Z/00/T0 —