Loading...
AR (13-1664)Ir z x P.O. BOX 1504 �`' - . , :' VOICE (760) 777-7012 • 78-495 CALLE TAMPICO FAX (760) 777-7011 ,, • 'SLA QUINTA, CALIFORNIA 92253 :' BUILDING.& SAFETY,DEPARTMENT . INSPECTIONS (760)777-7153s BUILDING PERMIT •^- rtrf Date; 3/28/14' ,Application Number: 13-00001664 Owner:" • " • 'Property Address: 49298 MONTANA WY= - JIM LATHROP ,f , ',�.APN:. 649-510-015- ' _ a _ - - �. - � '` -; 4 9 - 2 9 8 MONTANA* WAY a - Application description' - ADDITION - RESIDENTIAL ,� LA QUINTA _ CA 92253 o. - Property Zoning: LOW DENSITY.RES.IDENTIAL - ° ��- •r •�' ` " Application valuation 30811 _ t - `.- r• d ,' _ t - �• t, 4 _ Contractor: ! �, Applicant: •, Architect or Engineer: SANTUCCI BUILDERS f INC', , RD n .72529 BEAVERTAIL STREET ' .V _"i,' . 1{ ' PALM -DESERT, CA 92260 c%r�Y"4 (760) 578-7757" C� (op, 3A QU i l" L1Ct NO.. 820801...., ledd; bt pTTA ` • r ,LICENSED CONTRACTOR'S DECLARATION " _ - WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: `+. - -�.• Section 7000) of Division 3 of the Bu iness and Professionals Code,and my License is in full force and effect. _ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided '«•License Cla s: B - /` Liceryse No.: 820801 r for by Section 3700 of the Labor Code, for the performance of the work for which this permit is .. •♦' .f''� 1.�- •-� - _ . r - issued. „-. = • .�, }: Dat Contractor, r uif"•'�I��t�w ,} - ! , _ I have and will maintain workers'- compensation insurance, as required by Section 3700 of the Labor 7 - - Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION • - - _ ._ insurance carrier and policy number are: " I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License "Law for the ". •`? Carrier GRANITE STATE Policy Number 51759994-12 - r following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to - - I certify that, in the performance of the work for which this permit is issued, I shall not employ any i• - :.-� construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the - person in any manner so as to become subject to the workers' compensation laws of California, , ' . x permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I -sh uld become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or ••° .. 700 of the Labor Co , I shall forthwit c mply with those provisions. + "E,f that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by_ t{/ • - - -—�.h(`��� any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Da tf -� plicant: �,, •, �• .1 _ 1 I, as owner of the.property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The • ...v WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, ` : • SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND .,�. •• _ - , •, and who does the work himself or herself through his or her own employees, provided that the • I_ DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within'SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - , - one year of completion, the owner -builder will have the burden of proving that he or she did not build or • • - • - - • - improve for the purpose of sale.). 4 - _ "- - + .APPLICANT ACKNOWLEDGEMENT •+...----_T;-• (_ 1, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is herebymade to the Director of Building and Safety for a permit subject to'the ` I` ,, - �•.a a _ . 7044, Business and Professions Code: .,The Contractors', State License Law does not apply to an owner of. conditions and restrictions set forth on this application. - •,' � , - "property who builds or improves thereon, and who contracts for the projects with a contractor(s)-licensed,,:.. _ 1. Each person upon whose behalf this application is made, each person at whose request and for •- pursuant to the Contractors' State License Law.). - • - - '- whose benefit work is. performed under or'pursuant to any•permit issued as a result of this application, ' • (_) I m am exempt under Sec. , BAP.C. for this reason ' •the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - t ' * Date Owner:i 2: Any permit issued as a result of this application becomes null and void if work is not commenced..• ' • , - , .' a' - _. p„ s a within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY" • - `. - . permit to cancellation. - • •I hereby affirm under penalty of perjury that there is a construction lending "agency for the performance of the . , , I certify that I have read this application and state that the above information is correct. I agree to comply with all -work for which this permit is issued (Sec. 3097, Civ. C.). - •, "city and county ordinances and state laws relating to bu'�ing constructio nd hereby authorize representatives r - Lender's Name: ,,ti: • a,' of thi o_en er upon the above-mentioned propefor inspection purposes. • " , ' • - ., ,,. ` _-z$lgnature (Applicant or Agent�� vt/ • Lender's Address: - - �� •'f F - - - - r. - - " - - t ,.LQPERN11T ;. �. _ `r �, -:t. ,4 .� 2_ �Y+ e : 7 .• y;- 'r •�, ` .�_ ' • mss. # • `... ._ ., • • . ' r x,, �-:,r .: .•ar .. r .. , Application Number . . . . . 13-00.001664 Permit . . . ROOM ADDITION 2013- . �. Additional desc . Permit Fee 181.61 Plan Check Fee .00 Issue Date Valuation . . . . 0 pi Expiration Date 9/24/14 . Qty . Unit .Charge Per Extension 1.00 120.1200 LS MISC�ROOM ADDN, 1ST 100 SF 120.12 1.00 61.4900 EA MISC.ROOM ADDN, ADDL 500 SF 61.49 Permit . . . ELECTRICAL 2013. Additional desc . Permit'Fee . . . . 143.00 Plan Check Fee .00 Issue Date . . . Valuation 0 Expiration Date : 9/24/14 Qty Unit Charge Per Extension :00 23'.8300 LS ELEC'FIXTURES, FIRST 20 .0.0 .00 23.8300'EA" ELEC SERVICES 00 1.00 143.0000 LS ELEC NEW RES, FIRST 1 KSF 143.00 ------------------------.-- ----------- --------- - - - - -- ---------- ------------- Permit MECHANICAL 2013 Additional desc Permit Fee 95.34. Plan Check Fee .00 Issue Date Valuation .0 Expiration Date 9/24/14 Qty Unit Charge Per Extension 1.00 35.7500 EA MECH FURNACE 35.75 1.00 35.7500 EA MECH CONDENSER/COMP 35.75 2.00 11.92.00 EA MECH VENT FAN 23.84 Permit PLUMBING.2O13 - Additional desc . Permit Fee 59.60 Plan Check Fee 00 Issue Date Valuation . . 0 Expiration Date 9/24/14 Qty Unit ' Charge ' Per, ~ -- -- Extension 3.00 11.9200 EA PLBG FIXTURE/TRAP 35.76_,- 1.00 11.9200 EA PLBG WATER HEATER/VENT 11.92 1.00 11.9200:LS PLBG GAS SYS, 1-4 OUTLETS 11.92 -------------------------- ---------------------------------------------- Special Notes "and Comments NEW DETACHED CASITA 376 SQ.. FT. AND 22 LQPERMIT - - " Application Number . . . . . 13-00001664 -------------------------------------------- Special. Notes and Comments L ------------------------------- SQ. FT. MECH. AREA January 15, 2014 9:36:24 AM jjohnson. ------------------------------------------------------------ 4Other Fees ART IN PUBLIC PLACES -RES 20.00 Y BLDG STDS ADMIN (SB1473) 2.00 HOURLY PLAN CHECK 175.00 PLAN CHECK, ELECTRICAL 82.94 - PLAN CHECK, ROOM ADDITION 185.90 PLAN CHECK, MECHANICAL 57.20 PLAN CHECK, PLUMBING 78.66 STRONG MOTION (SMI) - RES 3.08 Fee summary. Charged Paid Credited Due Permit Fee Total. 479_55 .00 .00 479.55 Plan Check Total" .00 .00 .00 .00 Other Fee Total 604.78 .00 .00 604.78 Grand Total 1084.33 .00 .00 1084.33: B`n # t� City of La Quinta0 Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Pe mit # (. l� Project Address: W@'1 Owner's Name: A. P. Number: 1-70-01S. Address: 29 g .O� Legal Description: T -7X 9 P- City, ST, Zip: I N l 1 t Contractor: \` MI � L Telephone: P Address: 12, Project Description: City,. ST, Zip: RW Vv pu( ,q Telehone:/ '%'' a..4.. ?3`> State Lic. # : 2, 1 City Lic. Arch., Engr., Design C� t Address:PV City., ST, Zip: �-- Telephone: <<>..... "'"'``f" "" " "';s;,.,,•.>:••:: ^' ^ Construction Type: Occupancy: State Lic. #: Project type circle one): QAdd'n Alter Repair Demo Name of Contact Pers on: hgc3EP Sq. Ft.: 37� # Stories: I # Units: Telephone #,of Contact Person: 06 - 2 Estimated Value of Project: O� APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Recd TRACKING PERMIT FEES. Plan Sets Plan Check submitted1211AP Item Amount �j Structural Calcs.Reviewed, rea for corrections 1' 1 Plan Check Deposit Truss Calcs. Called Conta crs Plan Check Balance Title 24 Calcs. Plans picked up �l/ Construction Flood plain plan Plans resubmitted 3 Mechanical Grading plan god Review, ready for correction /issue ze I Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3,d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue i'v School Fees Total Permit Fees i �O i CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road ¢13ERMUDADUNESr U)'RANCNOMIRAGE b Date 4/2/14 La Quinta, CA 92253 �.' INDIAN WELLS .; No.: 32044 , q4 P QULM ENTA (760) 771-8515 QINDIO y7 o Owner .Jim Lathrop APN # 602-170-016. Address 49298 Montana Way. Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 . Type Detached Guest House Lot # No:. Street S.F. Lot # .. No. e S.F. Unit 1 .. .49298 Montana Way 37.6 Unit 6 EC VEU Unit 2 Unit 7 . Unit 3 Unit 8 Unit Unit 9 APR 0 2 2014 :Unit 5 Unit 10 CITY OF L,{ Comments COMMUNITY p EUINTq -VEL At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time.due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.20 X 376 S.F. or $1,203.20 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/1 St Bank - Jerry Santucci 'Check No. 1129643 Bank Name/Recipient of Certificate Telephone 760-578-7757 ' Funding 'Residential By Dr. Gary Rutherford. Superintendent Fee collected Payment Recd x0:00 y ar c v ey L_� _over/Under:' $1,203.20 _.. Signature rcG ` f ytx` NOTICE: Pursuant to Government Code Section 66020(d)(1), this rve.to notify you that the 90 -day approval period in which you mazy protest the fees or other payment identified above -will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which.those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original = Building Department. Applicant Copy- Applicant/Receipt Copy -.Accounting. . - -IZ�C�Ho LA QUINTA , MASTER ASSOCIATION ,Architectural .Control Committee January 30, 2014' 'James-,& Linda Lathrop; •' ,' 4109 Hidden Lakes Dr. " Kimberly, ID 83341. , Re: 49,298 Montana Way —Approval of Submission, . Dear Mr.'&.Mrs:-.Lathrop, The Architectural Control Committee'.reviewed your, submission fora ca' sita addition at your home at:'the above address located. within Rancho. La rQuinta Homeowners 'Association. - Your submission as.presented is approved contingent'on the following:. • Any damage 4o' the common area caused 'during this construction: shall` be repaired by the Owner tothesatisfaction of the:Association All +workis to be, done in .'accordance with allapplicable. requirements of governmental entities,, including the City of La Quinta,and :in-accordarice witK all. , -Homeowners Association. Architectural/Landscape 'G'uidelines' and governing documents. } - . •. :=1f eequired,•a City of La'Quinta building permit will be obtained'and copy. furnished _ to the' Association prior to commencement.'of work.. Materizils-shall.not be'stacked on the*street. No other'structural changes are .approved with,this submission' Good luck,. with your.project.' If.you have any questions please do'not riesitafe to contact the.oh-sit` e at (760) 777-8807. na ;T Rutherford= ilwatrd; CCAM', CMCA ; BUILDING ENERGY ANALYSIS REPORT s PROJECT: Lathrop Casita 49-298 Montana Way La Quinta, CA 92253 Project Designer: Garcia Design Associates 45-175 Panorama Dr. Suite A Palm Desert, CA 92260 (760) 272-9222 Report Prepared by: Jorge Garcia Garcia Design Associates 45-175 Panorama Drive Suite Al Palm Desert, CA 92260 (760) 272-9222 RECEIVED Job Number: MAR 1 3.2014 201'35� CITY OF LA QUINTA / � OF , COMMUNITY DEVELOPMENT Datef D/NG I& S� Q(!//��-� E 1 16/20 4�� �A DEPT -,/' ON VE '-® ogrE �-�/�� ON The EnergyPro computer program has been used to perform the calculations suhfr� his c pliance report. Th's program has approval and is authorized by the California Energy Commission for use with both the Residential an ene$id al 2008 Building nergy Efficiency Standards. This program developed by EnergySoft, LLC - www.ene om. Energ Pro 5.1 by Ener Soft User Number: 8961 RunCode: 2014-01-16717:31:41 ID: 2013-57 TABLE OF CONTENTS r " Cover Page + 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling toads Summary 11 Bul TY OF LA Q0IN7-A Ely SEPT. Fp APpRo VED NSTRUCT1pN DATE By EnergyPro 5.1 by EnergySoft Job Number: ID: 2013-57 User Number: 8961 I PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Lathrop Casita Building Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/16/2014 Project Address 49-298 Montana Way La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 376 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 743 New Door Opaque Door None 24 New Roof Wood Framed Attic R-38 376 Radiant Barrier New Slab Unheated Slab-on-Grade None 376 Perim = 82' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (S) 18.3 0.400 0.35 1.5 none Bug Screen New Left (tM 6.0 0.570 0.67 1.5 none Bug Screen New Right (E) 31.0 0.400 0.35 1.5 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 None n/a Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating��Cool yi7y s Duct n Ductrbocat'ion� R-Value Status HVAC System Ducted Dudley Aftic;rC,eiling In 11 v' ted 8.0 New �va- CP7: I` "NS_ T f Xui WATER HEATING DA -r,, ' JUN Ot . Type Ga1lon_s----WnJ�k, Distribution Status 1 Small Gas 50 62 _Kitchen-jEi�pe In New Ener Pro 5.1 by EnergySoft User Number: 8961 RunCode: 2014-01-16T17:31:41 ID: 2013-57 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Lathrop Casita Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/16/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. This building is modeled with reduced infiltration. Consequently the homeowner's manual provided by the builder to the homeowner shall include operating instructions for the homeowner on how to use mechanical ventilation to achieve adequate ventilation. Testing for reduced infiltration shall be performed as specified in AS TM E 779-03. This listing shall also report the target CFM50H required for the blower door test to achieve the modeled SLA and the minimum CFM50H (corresponding to an SLA of 1.5) allowed to avoid backdraft problems. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 38HDR024 --- 3 w/ 40QABO24 includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. This building has tight construction with reduced infiltration and a target blower door test range between 148 and 0 CFM at 50 pascals. The blower door test must be performed using the ASTM Standard Test Method for Determining Air Leakage Rate. WARNING - If this building tests below 148 CFM at 50 pascals, the house must either be provided with a ventilation opening that will increase the infiltration to this level (SLA=1.5) OR mechanical supply ventilation must be provided. The HVAC System HVAC System incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC System incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. SAS JI ° �A FOa �"'?®V4:- L) -r. D .,r v J T/3UC 1,'ON sy Ener Pro 5.1 by Ener Soft User Number: 8961 RunCode: 2014-01-16T17:31:41 ID: 2013-57 Page 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lathrop Casita ❑ Multi Family ❑ Existing+ Addition/Alteration 1/16/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.25 2.82 2.43 Space Cooling 90.62 93.77 -3.14 Fans 18.28 23.80 -5.52 Domestic Hot Water 57.42 50.18 7.24 Pumps 0.00 0.00 0.00 Totals 171.57 170.56 1.01 Percent Better Than Standard: 0.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 136 18 Fuel Available at Site: Natural Gas (w) 275 6 Raised Floor Area: 0 (N) 136 0 Slab on Grade Area: 376 (E) 275 31 Average Ceiling Height: 10.0 Roof 376 0 Fenestration Average U -Factor: 0.42 TOTAL: 55 Average SHGC: 0.38 Fenestration/CFA Ratio: 14.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and co lete. Documentation Author Company Garcia Design Associates 1/16/2014 Address 45-175 Panorama Drive Suite Al Name Jorge Garcia City/State/ZipCity/State/Zip Palm Desert, CA 92260 Phpne_(760) 272-9222 Signed Date The individual with overall design responsibility he eb certifies that -the cp`roposed=building design represented in this set of construction documents is consistent with the o her-compllance�formsand worksheets w tlh the specifications, and C3 1'. fti!Ar �c'F1V 12 { with any other calculations submitted with this permit appllcationCan�d recognizes i hat compliance using duct design, duct sealing, verification of refrigerant charge, insr lation iii% 1lation quality, and buildi den elope sealing require installer testing and certification and field verification by a�a�pr` ved H:EA'Vr5ter� Designer or Owner (per Business & PrLfessions CdOeN3TRUCTIpNCompany Garcia Design Associates ATE Address 45-175 Panorama Dr. Suite A Name ok9e-Ga-� BY !„ City/State/Zip Palm Desert, CA 92260 Phone (760) 272-9222 igne License # Date Ener Pro 5.1 by EnerigySoft User Number: 8961 RunCode: 2014-01-16T17:31:41 ID: 2013-57 Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Lathrop Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 118 0.069 R-21 180 90 New 4.3.1-A6 Zone 1-NewCasita Wall 245 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 -New Casita Door 24 0.500 None 270 90 New 4.5. i -A4 Zone i -New Casita Wall 136 0.069 R-21 0 90 New 4.3.1-A6 Zone 1-NewCasita Wall 244 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 -New Casita Roof 376 0.025 R-38 0 18 New 14.2.1-A21 Zone 1 -New Casita Slab 376 0.730 None 0 180 New 4.4.7-A1 Zone 1-NewCasita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 18.3 0.400 NFRC 0.35 1 NFRC 180 New 2008 PRESCR-XO Zone 1 -New Casita 2 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 3 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 4 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 5 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 6 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 7 Window 1.0 0.570 Default 0.67 Default 270 New GLASS BLOCK Zone 1 -New Casita 8 Window 6.0 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR-XO Zone 1 -New Casita 9 Window 12.5 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR-XO Zone 1 -New Casita 10 Window 12.5 0.400 NFRC 0.35 NFRC 90 New 2008 PRESCR-XO Zone 1 -New Casita (1) 1.1 -Factor Type: 11 &A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t I LExt I REA Dist I Len Right Fin Hat Dist Len H t 1 Bug Screen 0.76 5.0 4.0 1.5 2.01 2.0 2.0 2 Bug Screen 0.76 1.0 1.0 1.5 2.0 2.0 2.0 3 Bug Screen 0.76 1.0 1.0 1.5 2.0 2.0 2.0 4 Bug Screen 0.76 1.0 1.01.5 2.0 2.0 2.0 5 Bug Screen 0.76 1.0 1.0 !_ -x..2.0 2.0 2.0 6 Bug Screen 0.76 1.0 1.,Q :0-2-0=7 ( ;1.5 'V 2:0; ,- 1_0.-2-0. 7 Bug Screen 0.76 1.0 Ito , 1,$ _" 20 L.0'= CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Lathrop Casita Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1111612014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existina Altered Removed Volume Year Built HVAC System Room 1 376 3,760 Totals 1 3761 0 0 0 HVAC SYSTEMS System Name Oty. HeatingT e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 None n/a Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Oty Type Distribution Rated Input Btuh Tank Energy Cap. Factor al or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water Products 1 Small Gas Kitchen Pipe Ins 37,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS ri ®--HYDRONI.0 HEATING SYSTEM PIPING Control Hot Water Pipimg ��9LQ� 1 J ftn�gi A 1 � :�. � -0 Plenum Out ide BUrQd9 �.(J LA Q P`�� � &SAFETY Ti`1 DEp7 ; � 1 R V. is stem• N' a7ne Pipe Length Pipe Diameter Insul. Thick. Q HP ❑ "U"ON DA rJ= ❑ — BY Ener Pro 5.1 by Ener Soft User Number: 8961 RunCode: 2014-01-16T17:31:41 ID: 2013-57 Pae 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Lathrop Casita Date 1/16/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF- . 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage' §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. s150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is— equipped se ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. - 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater%tank; non=recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards TaOe'1150 §1500)2: Cooling system piping (suction, chilled water, or brine Ii es);agdLpiprlg`insulated=l etween h -ti-- source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. G c� .0 n rte_' §1500)2: Pipe insulation for steam hydronic heating systems a a or4/hot water•"s'ystems;>1155 psi"meets th��e�quire � nts of Standards Table 123-A. Fri` r, p r )%/ r— ", I A "� h l.( �nrc� dL@ p M N 150 3A: Insulation is protected from damage, includingthat due to sunli ht, moisture] • uj • rnent-maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor ret dh bi is enclosed entirely in conditioned space. • I UA r8 I 150 4: Solar water -heating systems and/or collectors are certif dQy-the.S'oLar RatiWacLd Certification Co oration. r EnergyPro 5.1 by EnergySoft i User Number. 8961 RunCode: 2014-01-16717:31:41 ID: 2013-57 Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Lathrop Casita 1/16/2014 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Al 50(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy-luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi-scemelprocirammable_control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 sgdare;fee""' land utility�rooms ahhigh=efficacy and controlled by a manual-on occupant sensor. 8UIL t�tn,-. _ LA gar im §150(k)9: Permanently installed lighting that is internal to cabinefs shall use no moo"re`=thW20 watts of powertper linear foot of �' illuminated cabinet. r � � r DEPT CONS EC) LNr�H N OA7-E _� QY EnergyPro 5.1 by EnergySoft User Number: 8961 RunCode: 2014-01-16T17:3 . I � Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Lathrop Casita 1/16/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. BUIL, FO @ N DATE .i Y EnergyPro 5.1 by EnergySoff User Number: 8961 RunCode: 2014-01-16717:31:41 /D: 2013-57 Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lathrop Casita Date 1/16/2014 System Name HVAC System Floor Area 376 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 236 4,828 Return Vented Lighting 0 Return Air Ducts 279 Return Fan 0 Ventilation 7 0 0 Supply Fan 407 Supply Air Ducts 279 TOTAL SYSTEM LOAD 5,792 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 0 200 211 6,537 Total Output Btuh 0 Output Btuh/s ft 0.0 321 Cooling System 0 Output per System 23,000 0 0 0 Total Output Btuh 23,000 200 407 Total Output Tons 1.9 321 Total Output Btuh/s ft 61.2 Total Output s ft/Ton 196.2 6,773 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 38HDR024 --- 3 w/ 40QABO24 17,236 2,118 0 Airflow cfm/s ft 2.13 Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 17,236 2,118 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 IF 97 OF 97 OF Heating Coil Supply Fan 800 cfm 97 °F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 °F Outside Air 0 cfm Ar 75 / 62 OF 75162 OF 55 / 54 OF 55 154 OF yO - LA. ��It� I t " Supply 800 Fan ' & SAP E'' Cooling Coil 00cfm APS D Sr° .. FOR ftftt T �ROOM rl OgTE 75161 OF EnergyPro 5.1 by EnergySoft User Number. 8961 RunCode: 2014-01-16Tf7:31:41 ID: 2013-57 Page 11 0111