Loading...
BRES2016-018078-495 CALLE TAMPICO D VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 6/29/2016 Application Number: BRES2016-0180 Owner: Property Address: 53660 AVENIDA MONTEZUMA ANTHONY MARTIN MANQUERO- APN: 774101007 53660 AVENIDA MONTEZUMA Application Description: ANTHONY MONGERO / REPLACE WINDOWS REMODEL LA QUINTA, CA 92253 Property Zoning: Application Valuation: $5,000.00 Applicant: ANTHONY MARTIN MANQUERO 53660 AVENIDA MONTEZUMA LA QUINTA, CA 92253 JUN 2 Od 2016 CITY OF LA QUINTA TY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to'construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars #ec.0704S owner of the property, or my employees with wages as their sole enation, will do the work, and the structure is not intended or offered for sale. 4, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold wi hin one year of completion, the owner -builder will have the burden of proving that or did not build or improve for the purpose of sale.). �stluct owner of the property, am exclusively contracting with licensed contractors TO cothe project. (Sec. 7044, Business and Professions Code: The Contractors' Stateicense Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to Ae Ce Co actors' State License Law.). I m exempt under Sec. . B.&P.C. for this reaso Date:. Owhe7: CONSTRUCTION LENDING AGEN I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is -issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Contractor: ANTHONY MARTIN MANQUERO 53660 AVENIDA MONTEZUMA LA QUINTA, CA 92253 (562)426-4026 LIc. No.: WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: ~�( Applicant WARNING: FAILURE TO SECURE WORKERS' MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date ` — < `- Signature (Applicant or Agen DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 6/29/16 'PAID BY METHOD RECEIPT # CHECK # CLTD BY ANTHONY MARTIN MANQUERO DEBIT R16684 RSE Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1:00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $0.65 $0.65 6/29/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY. ANTHONY MARTIN MANQUERO DEBIT R16684 RSE Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.65 $0.65 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 •$60.91 $60.91 6/29/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY ANTHONY MARTIN.MANQUERO DEBIT R16684 RSE DESCRIPTION -ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000-42600 0 $110.22 $110.22 6/29/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY ANTHONY MARTIN MANQUERO DEBIT R16684 RSE Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 $171.13 TOTALS: $172.78 $172.78 Description: ANTHONY MONGERO / REPLACE WINDOWS REMODEL ACTION DATE COMPLETION DATE NOTES Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 6/29/2016 RSE Approved: 6/29/2016 RSE Parcel No: 774101007 Site Address: 53660 AVENIDA MONTEZUMA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA AT VALE LA OUINTA Block: 195 Lot: 16 Issued: UNIT 19 NOTE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $5,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 4 DOORS REPLACE AND 1 WINDOW TO DOORE. VERIFIED EXISTING CONDITIONS OF ENERGY EFFECTIVENESS. 2013 CALIFORNIA BUILDING CODES. CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES CE2016-000929 THIS IS THE CODE CASE ON THE HOUSE MAKE NOTE RAMSES SEVILLA 6/29/2016 6/29/2016 HAVE TO LOOK AT SCOPE OF WORK BECAUSE IT LOOKS LIKE THEY REPLACE HEADER OF WINDOW CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT ANTHONY MARTIN MANQUERO 53660 AVENIDA LA QUINTA CA 92253 (562)426-4026 MONTEZUMA CONTRACTOR ANTHONY MARTIN MANQUERO 53660 AVENIDA LA QUINTA CA 92253 (562)426-4026 MONTEZUMA OWNER ANTHONY MARTIN MANQUERO 53660 AVENIDA LA QUINTA CA 92253 (562)426-4026 . MONTEZUMA Printed: Wednesday, June 29, 2016 3:07:35 PM 1 of 2 - CR?SYSTEMS INSPECTIONS PAnFNT PROMICT5 REVIEWS w RETURNED. STATUS REMARKS REVIEW TYPE REVIEWER SENT. DATE DUE DATE DATE NOTES Printed: Wednesday, lune 29, 2016 3:07:35 PM 2 of 2 RLJ L1 SYSTEAAS FINANCIAL • •• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 6/29/16 R16684 DEBIT ANTHONY MARTIN RSE MANQUERO Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: SMI -RE 101-0000-20308 0 $0.65 $0.65 6/29/16 R16684 DEBIT ANTHONY MARTIN RSE MANQUERO Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.65 $0.65 DOOR/WINDOW, 101-0000-42400 0 $60.91 $60.91 6/29/16 R16684 DEBIT ANTHONY MARTIN RSE. REPLACE FIRST 7 MANQUERO DOOR/WINDOW, 101-0000-42600 0 $110.22 $110.22 6/29/16 R16684 DEBIT ANTHONY MARTIN RSE REPLACE, FIRST 7 PC MANQUERO Total Paid for WINDOW/SLIDING GLASS $171.13 DOOR/FENESTRATION: ,$171.13 TOTALS: INSPECTIONS PAnFNT PROMICT5 REVIEWS w RETURNED. STATUS REMARKS REVIEW TYPE REVIEWER SENT. DATE DUE DATE DATE NOTES Printed: Wednesday, lune 29, 2016 3:07:35 PM 2 of 2 RLJ L1 SYSTEAAS i &SAF�DEP T . 13UILOINC61-V- OF LA ()UIN-TA I A����� FOR CONSTRUCTION i � it SiL�o PAP) 64 wt*me-+w,�t C� Bin # City of La Quinta Building SZ' Safety Division 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:„�'4 �U4�� Owner's Name: E o A. P. Number: Address: Legal Description: City, ST, Zip: Contractor: Telephone: 2G one: Address: Project Description: ' City, ST, Zip: IS K> Telephone: C � tG� G 6 State Lie. # : City Lie. #: Arch., Engr., Designer: Address: City, ST, Zip: f h Telephone: one: Construction s tnT OccP u ane o Type -Occupancy: P Y: State S Lie. #• Project type �c•tt cle one): New Add'n Alter Re air Demo Name of Contact Person:I Sq. # Stories: # Units: Telephone # of Contact Person: (� Estimated Value of Project: v (CANT: DO NOT WRITE BELOW THIS LINE 9 Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cafes. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°” Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"! Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees >✓ 26 16- 60 0 C Zq CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Date/time: 15:17, Tue, Jun 28, 2016 Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd CF1 R -PRF -01 Page 1 of 7 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Manquero Remodel 04 06 02 Calculation Description Single Fam - Atch Gar -Sngl Stry 08 - Energy Use (kTDV/fP-yr) 03 Project Location 53360 Montezuma Ave Compliance Margin Percent Improvement 04 City La Quints, California 06, Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version CBECC-Res 20134 (744) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 266 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftp) 1537 16 Number of Zones 1 16 Slab Area (ft2) 0 - 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available No 20 Addition Slab Area (ft2) 0 210 1 ■ saw ■ ■ ■— ■ I COMPLIANCE RESULTS gl-InnwnDEPT. 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification • 03 This building Incorporates one or more Special Features shown below Registration Number Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 �E�='�tew ta a — JUN 2 9.2016 C F LA Q49ItM J&% LOPMENT C+�{♦� Report Generated at: 2016-06-28 15:18:17 ENERGY USE SUMMARY 04 06 06 07 08 - Energy Use (kTDV/fP-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.10 0.65 2.45 79.0% Space Cooling 142.50 114.93 27.57 19.3% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 24.83 24.83 0.00 Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 170.43 140.41 30.0 17.8% Registration Number Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 �E�='�tew ta a — JUN 2 9.2016 C F LA Q49ItM J&% LOPMENT C+�{♦� Report Generated at: 2016-06-28 15:18:17 i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016 Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ceiling has high level of insulation CFI R -PRF -01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • —None — Cooling System Verifications: — None — HVAC Distribution System Verifications: • — None — Domestic Hot Water System Verifications: • — None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for fighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVtf2-yr)' 236.68 206.66 30.02 12.7% ' Includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Manquero Remodel 1537 1 3 1 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 'Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House - One Zone Conditioned HVAC System - Existing 1537 8 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance _ Report Version - CFiR-04072016-744 HERS Provider: Report Generated at: 2016-06-28 15:18:17 J CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016 Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd CFI R -PRF -01 Page 3 of 7 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 01 02 03 04 06 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (f:2) Window & Door Area (W) Tilt (deg) Status Verified Existing Condition Bath -Storage N Wall Whole House - One Zone Ext Wali Assy - R13+1 EPS 356 Left 168 6 90 Existing No BED2 - N Whole House - One Zone Ext Wall Assy - R13+1 EPS 356 Left 128 0 90 Existing No BED2 - E Whole House - One Zone Ext Wall Assy - R13+1 EPS 86 Bads 96 20 90 Existing No MBATH-E Whole House - One Zone Ext Wall Assy - R13+1 EPS 86 Bads 64 4.8 90 Existing No MSTRBED - E Whole House - One Zone Ext Wall Assy - R13+1 EPS 86 Bads 112 10 90 Existing No LIVING -S Whole House - One Zone Ext Wall Assy - R13+1 EPS 176 Right 136 0 90 Existing No KITCH - S Whole House - One Zone Ext Wall Assy - R13+1 EPS 176 Right 80 0 90 Existing No KITCHEN -E Whole House - One Zone Ext Wall Assy - R13+1 EPS 86 Bads 184 40.5 90 Altered N/A FAMILY - W Whole House - One Zone Ext Wall Assy - R13+1 EPS 266 Front 96 40.5 90 Altered N/A LIVING - W Whole House - One Zone Ext Wall Assy - RI 3+1 EPS 266 Front 144 81 90 Altered N/A MSTRBED-S Whole House - One Zone Ext Wali Assy - RI 3+1 EPS 176 Right 112 40.5 90 Altered N/A Ceiling (below attic) 1 Whole House - One Zone Ceiling Assy - Existing 1537 Existing No Garage -E Garage Ext Wall Assy - R13+1 EPS 176 Right 160 0 90 Existing No Garage - N Garage Ext Wall Assy - R13+1 EPS 86 Bads 160 0 90 Existing No Garage -S Garage Ext Wall Assy - R13+1 EPS 176 Right 100 0 90 Existing No Int Com Wall - Fam Rm Garage»Whole House - One Zone T24-2008 IntWall 2x4 16oc R13 160 0 Existing No . Int Com Wall - Kitch Garage»Whole House - One Zone T24-2008 IntWall 2x4 16oc R13 64 0 Existing No Ceiling (below attic) 2 Garage Garage ceiling 400 Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emlttance Barrier Cool Roof s Condition Attic Asphalt Shingle Roof Ventilated 3 0.1 0.85 Yes No Enigstl No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-06-28 15:18:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation DatefTlme: 15:17, Tue, Jun 28, 2016 Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd CFI R -PRF -01 Page 4 of 7 WINDOWS 01 02 03 04 06 06 07 08 09 10 11 Name Surface (Orientation- Azimuth) Width(ft) Height (ft) Multlplle r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition Bath -N -1 Bath -Storage N Wall (Left -356) — — 1 6.0 0.32 0.25 Insect Screen (default) Existing No BED2-E-2 BED2 - E (Back -86) — — 1 20.0 0.38 0.35 Insect Screen (default) Existing No MBATH-E-3 MBATH-E (Back -86) — — 1 4.8 0.38 0.35 Insect Screen (default) Existing No MBED-E-4 MSTRBED - E (Back -86) — — 1 10.0 0.38 0.35 Insect Screen (default) Existing No DOORS 01 02 03 04 05 01 02 03 04 06 06 Name Side of Building Area (f:2) U -factor Status Verified Existing Condition KITCH - DFDoor - 6 KITCHEN -E 40.5 0.28 New No FAMILY - W DFDoor -9 FAMILY - W 40.5 0.28 New No LIVING -W- DFDoor-8 LIVING - W 40.5 0.28 New No LIVING -W DFDoor - 7 LIVING - W 40.5 0.28 New No MBED - DFDoor -5 MSTRBED- 40.5 0.28 New No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Sheathing/ Insulation: R4 Sheathing Ext Wall Assy = R13+1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.053 Exterior Finish: R4 Synthetic Stucco • Cavity/Frame: no insul. /2x4 Top Chrd 20 Top Chord of Roof Truss c@ 24 Roof Deck: Wood Siding/sheathing/decking Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling In. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Ceiling Assy - Existing attic) Wood Framed Ceiling 2x4 ® 16 in. O.C. R 42 0'.023 Over Floor Joists. R-32.9 insul. • Inside Finish: Gypsum Board T24-2008 IntWall2x4 16oc Cavity/Frame: R -13/2x4 R13 Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board Ceilings (below Inside Finish: Gypsum Board Garage ceiling attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. none 0.472 Cavity/ Frame: no insul. /2x4 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version,- CFiR-04072016-744 Report Generated at: 2016-06-28 15:18:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Description: ALERATION - Compliance Report Calculation Date/Time: 15:17, Tue, Jun 28, 2016 Input File Name: Manquero Remodel-160527.ribd CFI R -PRF -01 Page 5 of 7 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW System -Existing Equip DHW Standard Water Heater -Existing Equip 1 - none - Existing No WATER HEATERS 01 02 03 04 OS 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) Water Heater -Existing Equip Electric Resistance Small Storage 50 0.97 EF 7000 -watts 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 as 06 07 Name. Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW System -Existing Equip n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Type HSPF/COP Cap 47 Cap 17 Heating System Cooling System SplitHeatPump - Central split heat 7.2 44000 40000 12 10.42 pump Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC Fan HVAC System - Heat Pump Heating Heat Pump Yes Heat Pump Yes Distribution System 1537 Existing No Existing and Cooling System -Extg Equip -fig Equip System - Exstg -Exstg Equip HVAC - HEATING SYSTEMS: Heat Pumps 01 02 03 04 06 06 07 Heating Cooling Name Type HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump -Extg Equip SplitHeatPump - Central split heat 7.2 44000 40000 12 10.42 pump Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-06-28 15:18:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016 Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd CF1 R -PRF -01 Page 6 of 7 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verlfled_Exlsting_ HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status C6ndltlon*7 J Verification Distribution System - Ducts located in attic Existing (not- 4.2 Attic Attic None Existing No N/A Exstg specified) IAQ (indoor Air Quality) FANS 01 02 03 04 06 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans Whole House Fan 0 0.1 1 PROJECT NOTES 1. EE Fenestration Upgrade - Removal & Replacement 2. Additional alterations are cosmetic Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-06-28 15:18:17 ' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Manquero Remodel Calculation Description: ALERATION - Compliance Report Calculation Date/Time: 15:17, Tue, Jun 28, 2016 Input File Name: Manquero Remodel-160527.ribd CFIR-PRF-01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 17 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Docum tati Ai e, W 6 LC-,Sli 1/' 711 1 Company: Signa re D te: Address: l �.o . Z � CE:A/HE S Ce ification Identificatio If applicable): City/State2IF/� ^� 64 Phone:` RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: Address: License: City/State/Zip: Phone: Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-06-2815:18:17 MASONITE — CERTIFIED THERMAL PERFORMANCE DATA FOR MANQUERO FIBERGLASS DOORS CUSTOMER NAME: Anthony Manquero ADDRESS: 12344 Either Rd La Quinta,Ca. PURCHASE ORDER NO.: ORDER DATE: Detailed Product Ratings MamCxtu2r: Nas 1. tme U-1 Corp rvaon Send Name: N!"onite Fftemless sin Dam OpenrurTyPe: e05 Atr leaea9e: .0.3 Key: Click the Colum headers to son the data acardinq to the cotumn header. A dash = In a mthly Cal— (SHGC IVr) W kates deet there are no NERC CemM.d values fm plat htlhMual proetdt. CPD# Group ID Manufacturer Product Code Frame/Sash Type U -factor SHGC VT Condensation Resistance STN -K-29-33457-00001 1 S C540 -CL N FL W/N WD/NA 0.28 0.17 0.31 -1 Glazing Layers Low -E G Widths Spacer Gap Fill Grid Divider Tint 2 0.03664505(2)1 0.749998 Al -D ARG/AIR 90/10 N -1 CL CERTIFICATION OF ARGON FILL Michael, The snap shots shown below illustrate the actual certification number and label placed on the product during the manufacturing process. As you mentioned in your email our thermal performance sheets need to be updated to include the 0.02 (Btu/h-ft2-F) non -thermal sill add-on rating option. The outswing door unit ordered utilizes this sill add-on option which makes the over unit performance 0.28(U- factor)/0.17(SHGC). I hope this information is helpful. Based on Stacey's comment below this particular unit is assembled with LowE Argon filled. Our plant confirmed IowE argon will be used in this order. Thank You. Tank Reid Customer Service Manager - East Coast the dutiful door - P: 877-431-3667 1 F: 866-838-1267 1 www.masonite.com I saceves@masonite.com X�ih' TO WIN! MASONITE - CERTIFIED THERMAL PERFORMANCE DATA FOR MANQUERO FIBERGLASS DOORS MANUFACTURERS PERFORMANCE CERTIFICATION LABEL Fiberglass Entry & Patio Door with Outswing or ADA Sill STN -K-29* ENERGY PERFORMANCE RATINGS U -Factor (Btuft-tJ-'F) / Solar Heat. Gain Coefficient (SHGC) INDIVIDUAL OPTION NUMBER PRODUCT DESCRIPTION DEFAULT FRAME" 1/4 Lite 5410 in` 1/2 Lite 5900 In, 3/4 Lite 51100 in Full Lite >1100 in' Decorative IG 0.22/0.08 0.25/0.15 0.28/0.20 0.31/0.27 (Glass Type 0) 23582-00001 23579-00001 23580-00001 23581-00001 -Decorative IG with Low-E/Argon N/A N/A 0.24/0.18 0.27/0.24 (Glass Typo Iq 23628-00001 23629-00001 Blinds Clear Triple Pane N/A 0.23/0.14 N/A 0.28/0.26 36216-00001 36217-00001 Blinds Low -E Tripie Pane with Grids N/A 0.22/0.10 N/A 0.26/0.19 36222-00001 36223-00001 Blinds Dual Pane Clear N/A 0.29/0.19 0.33/0.26 0.38/0.34 (Glass Typo TB) 32947-00001 32948-00001 32949-00001 -Blinds Dual Pane Low -E N/A 0.26/0-10 0.28/0.13 0.32/0.17 (Glass Type GB) 33179-00001 33180-00001 33181-00001 Blinds Dual Pane Low -E N/A 0.27/0.16 0.30/0.21 0.34/0.28 (0ass Type MB) 33171-00001 33172-00001 33173-00001 - Argon Dual Pane 1° Pane 1 N/A 0.24/0.10 0.26/0.13 0.28/0.17 (Glass Type D) 33455-00001 33456-00001 33457-00001 -t ow- Dual Pane 1" with 1" w th Grids N/A 0.24/0.09 0.26/0.12 0.28/0.15 (Glass Type D) 33527-00001 33528-00001 33529-00001 Low -E Dual Pane 1" 0.22/0.09 0.26/0.16 0.29/0.21 0.32/0.28 (Class Type M) 33410-00001 33411-00001 33412-00001 33413-00001 Low -E Dual Pane Grids 1' 0.22/0.08with 0.26/0.14 0.29/0.19 0.32/0.25 (Glas3 Type M) 33482-00001 33483-00001 33484-00001 33485-00001 Low -E Dual 'Pane 1' 0.22/0.05 0.25 / 0.10 0.27/0.13 0.30/0.17 (Glas3 Type G) 33418-00001 1 33419-00001 33420-00001 33421-00001 LowDual Pane 1' with Grids 0.22/0-05 0.25/0.09 0.27/0.12 0.30/0.15 iGtass Type G) 33490-00001 33491-00001 33492-00001 33493-00001 Clear IG 1/2' 0.24/0.10 0.30/0.19 0.34/0.26 0.39/0.34 (Glass Type 7) 33394-00001 33395-00001 33396-00001 33397-00001 Clear with Grids 1/2" 0.24/0-09 0.31/0.17 0.35/0.22 0.41 / 0.30 (Class Typo T) 33406-00001 33407-00001 33408-00001 33409-00001 Clear IG 1" 0.24/0.10 0.29/0.19 0.32/0.26 0.37/0.34 (Gla33 Type T) 33386-00001 33387-00001 1 33388-00001 33389-00001 Clear With Grids 1 1" 0.24/0.09 0.29/0.17 0.32/0.22 0.37/0.30 (Class Type T) 33398-00001 33399-00001 33400-00001 33401-00001 Low -E Vent Lite N/A 0.25/0.07 N/A N/A (Glass Type G) 36723-00001 Clear Vent Lite N/A 0.28/0.12 N/A NIA (Glass Type T) 36722-00001 Flush or Embossed (Opaque) 0.17/0.01 1 8 58 5-00001 Air Loakage 50.3 cf Wft' t. The Home Depot Special Order Quote Customer Agreement M H6630-3883 huh, Printed Date: 5/16/2016 Customer Information Store Information Name ANTHONY MANQUERO Store Number 6630 Address 5927 CERRITOS AVE Address 79900 HIGHWAY 111 LONG BEACH, CA 90805 LA QUINTA, CA 92253 Primary Phone 562-426-4026 Associate ADRIANA Secondary Phone 562-426-4026 Item # Item Description Room Location Unit Price Qty Total Price www.HomeDepot.com Page 1 of 4 Printed By: ADRIANA Date Printed: 5/16/20161:04 PM 100-1 Masonite Smooth Double Prehung 74 x 80.375 RO Width = 74.75 RO Height = 80.875 Call Width = 72" Call Height = 80" Width = 74 Height = 80.375 Show only Energy Star products = Yes - Show only Energy Star Handing -Swing = Double Right Hand Outswing Swing (for Energy Star) = Outswing Panel Thickness = 13/4" Glass Type = Clear Glass No Grille Glass Shape = Full Lite Rectangle Door Style = Full Lite Rectangle Grain Texture = No Texture (Smooth) Material = Belleville Smooth Fiberglass Glass Size = 122 - 22x64 rect Glass Style = 1 Lite Glass Caming = No Caming Low -E = Yes - Soft Coat Door Finish Type = Unfinished Exterior Color= Unfinished Interior Color = Unfinished Jamb Width= 4 9/16" Jamb Type = Primed Wood Matching Brickmould = No Jamb Finish Type = Unfinished Jamb/Brickmould Color= Unfinished Handleset Style = None Passive Door Handleset = No Lock Prep Active Panel = 5 1/2" Double Bore Lock Prep Passive Panel = Single Bore Hinge Type = Standard Hinge for Fiberglass Door Hinge Finish = Antique Black Sill Type = Bumper Sill (matches Outswing door) Sill Finish = Antique Black Petdoor Installed = No Mailslot Cutout = No Peephole Installed = No Is this door/sidelite Energy Star? = Yes Is this unit Energy Star Certified? = Yes Additional Services = None Re -Order = No Room Location = Back SKU =47657S Vendor Name = S/O STANLEY/MASONITE Vendor Number = 60695971 Customer Service = 1-877-431-3667 Catalog Version Date = 5/2/2016 co� 5 $4,260.25 $724.27 $3,621.35 Save $638.90 (15%) until 5/18/2016 • S/O STANLEY/MASONITE-476575 Promotion until 5/18/2016 El • www.HomeDepot.com Page 2 of 4 Printed By: ADRIANA Date Printed: 5/16/20161:04 PM Q q ESTABLISHED IN 1918 AS A PUBLIC AGENCY G� COACHELLA VALLEY WATER DISTRICT POST OFFICE BOX 1058 • COACHELLA, CALIFORNIA 92236 • TELEPHONE (760) 398-2651 • FAX (760) 398-3711 DIRECTORS: OFFICERS: JOHN W. McFADDEN, PRESIDENT STEVEN B. ROBBINS, PETER NELSON, VICE PRESIDENT GENERAL MANAGER -CHIEF ENGINEER TELLIS CODEKAS JULIA FERNANDEZ, SECRETARY RUSSELL KITAHARA DAN PARKS, ASST. TO GENERAL MANAGER PATRICIA A. LARSON REDWINE AND SHERRILL, ATTORNEYS Gene Caswell 53-660 Avenida Montezuma La Quinta, California 92253 Dear Mr. Caswell: Subj ect Aguust 26, 2003 RECEIVED AUG 2 9 2003 PUBLIC WORKS 53-265 Avenida Juarez Account No. 606123,170.0.4 File: 1112. In response to your inquiry, all sewer requirements for the above -referenced property have been met. It will be the homeowner's responsibility to connect their pipeline to the sewer lateral. If you have any questions please contact Rosie Anacleto, Customer Service Representative, extension 2420. Yours very truly, 4,,;S eve 4Robbnsi eneral Manager -Chief Engineer RIA:ra bc: City of La Quinta Post Office Box 1504 La Quinta, California 92253 TRUE CONSERVATION USE WATER WISELY