BRES2016-018078-495 CALLE TAMPICO D VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 6/29/2016
Application Number: BRES2016-0180 Owner:
Property Address: 53660 AVENIDA MONTEZUMA ANTHONY MARTIN MANQUERO-
APN: 774101007 53660 AVENIDA MONTEZUMA
Application Description: ANTHONY MONGERO / REPLACE WINDOWS REMODEL LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $5,000.00
Applicant:
ANTHONY MARTIN MANQUERO
53660 AVENIDA MONTEZUMA
LA QUINTA, CA 92253
JUN 2 Od 2016
CITY OF LA QUINTA
TY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to'construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
#ec.0704S
owner of the property, or my employees with wages as their sole
enation, will do the work, and the structure is not intended or offered for sale.
4, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
wi hin one year of completion, the owner -builder will have the burden of proving that
or did not build or improve for the purpose of sale.).
�stluct
owner of the property, am exclusively contracting with licensed contractors
TO
cothe project. (Sec. 7044, Business and Professions Code: The Contractors'
Stateicense Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
Ae Ce Co actors' State License Law.).
I m exempt under Sec. . B.&P.C. for this reaso
Date:. Owhe7:
CONSTRUCTION LENDING AGEN
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is -issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
Contractor:
ANTHONY MARTIN MANQUERO
53660 AVENIDA MONTEZUMA
LA QUINTA, CA 92253
(562)426-4026
LIc. No.:
WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: ~�( Applicant
WARNING: FAILURE TO SECURE WORKERS' MPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date ` — < `- Signature (Applicant or Agen
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0 $1.00
$1.00
6/29/16
'PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
ANTHONY MARTIN MANQUERO
DEBIT
R16684
RSE
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1:00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$0.65
$0.65
6/29/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY.
ANTHONY MARTIN MANQUERO
DEBIT
R16684
RSE
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.65 $0.65
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE FIRST 7
101-0000-42400
0
•$60.91
$60.91
6/29/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
ANTHONY MARTIN.MANQUERO
DEBIT
R16684
RSE
DESCRIPTION
-ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, FIRST 7 PC
101-0000-42600
0
$110.22
$110.22
6/29/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
ANTHONY MARTIN MANQUERO
DEBIT
R16684
RSE
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $171.13 $171.13
TOTALS: $172.78 $172.78
Description: ANTHONY MONGERO / REPLACE WINDOWS REMODEL
ACTION DATE
COMPLETION DATE NOTES
Type: BUILDING, RESIDENTIAL Subtype: REMODEL
Status: APPROVED
Applied: 6/29/2016 RSE
Approved: 6/29/2016 RSE
Parcel No: 774101007 Site Address: 53660 AVENIDA MONTEZUMA LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA AT VALE LA OUINTA Block: 195
Lot: 16
Issued:
UNIT 19
NOTE
Lot Sq Ft: 0 Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $5,000.00 Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0
No. Unites: 0
Details: 4 DOORS REPLACE AND 1 WINDOW TO DOORE. VERIFIED EXISTING CONDITIONS OF ENERGY EFFECTIVENESS. 2013 CALIFORNIA
BUILDING CODES.
CHRONOLOGY TYPE STAFF NAME
ACTION DATE
COMPLETION DATE NOTES
CE2016-000929 THIS IS THE CODE CASE ON THE HOUSE MAKE
NOTE
RAMSES SEVILLA
6/29/2016
6/29/2016
HAVE TO LOOK AT SCOPE OF WORK BECAUSE IT LOOKS LIKE
THEY REPLACE HEADER OF WINDOW
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP PHONE
FAX
EMAIL
APPLICANT
ANTHONY MARTIN MANQUERO
53660 AVENIDA
LA QUINTA
CA
92253 (562)426-4026
MONTEZUMA
CONTRACTOR
ANTHONY MARTIN MANQUERO
53660 AVENIDA
LA QUINTA
CA
92253 (562)426-4026
MONTEZUMA
OWNER
ANTHONY MARTIN MANQUERO
53660 AVENIDA
LA QUINTA
CA
92253 (562)426-4026
.
MONTEZUMA
Printed: Wednesday, June 29, 2016 3:07:35 PM 1 of 2
- CR?SYSTEMS
INSPECTIONS
PAnFNT PROMICT5
REVIEWS
w
RETURNED. STATUS REMARKS
REVIEW TYPE REVIEWER SENT. DATE DUE DATE DATE NOTES
Printed: Wednesday, lune 29, 2016 3:07:35 PM 2 of 2
RLJ L1 SYSTEAAS
FINANCIAL
•
••
DESCRIPTION ACCOUNT QTY
AMOUNT
PAID
PAID DATE
RECEIPT # CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE 101-0000-20306 0
$1.00
$1.00
6/29/16
R16684
DEBIT
ANTHONY MARTIN
RSE
MANQUERO
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00
$1.00
BSA:
SMI -RE
101-0000-20308
0
$0.65
$0.65
6/29/16
R16684
DEBIT
ANTHONY MARTIN
RSE
MANQUERO
Total Paid for STRONG MOTION INSTRUMENTATION SMI:
$0.65
$0.65
DOOR/WINDOW,
101-0000-42400
0
$60.91
$60.91
6/29/16
R16684
DEBIT
ANTHONY MARTIN
RSE.
REPLACE FIRST 7
MANQUERO
DOOR/WINDOW,
101-0000-42600
0
$110.22
$110.22
6/29/16
R16684
DEBIT
ANTHONY MARTIN
RSE
REPLACE, FIRST 7 PC
MANQUERO
Total Paid for WINDOW/SLIDING GLASS
$171.13
DOOR/FENESTRATION:
,$171.13
TOTALS:
INSPECTIONS
PAnFNT PROMICT5
REVIEWS
w
RETURNED. STATUS REMARKS
REVIEW TYPE REVIEWER SENT. DATE DUE DATE DATE NOTES
Printed: Wednesday, lune 29, 2016 3:07:35 PM 2 of 2
RLJ L1 SYSTEAAS
i
&SAF�DEP
T
.
13UILOINC61-V- OF LA ()UIN-TA I
A�����
FOR CONSTRUCTION
i � it
SiL�o PAP) 64 wt*me-+w,�t C�
Bin #
City of La Quinta
Building SZ' Safety Division
78-495 Calle Tampico .
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address:„�'4 �U4��
Owner's Name: E o
A. P. Number:
Address:
Legal Description:
City, ST, Zip:
Contractor:
Telephone: 2G
one:
Address:
Project Description: '
City, ST, Zip:
IS
K>
Telephone:
C � tG� G 6
State Lie. # :
City Lie. #:
Arch., Engr., Designer:
Address:
City, ST, Zip:
f
h
Telephone:
one:
Construction s tnT OccP u ane
o Type -Occupancy:
P Y:
State S Lie. #•
Project type �c•tt cle one): New
Add'n Alter Re air Demo
Name of Contact Person:I
Sq.
# Stories:
# Units:
Telephone # of Contact Person: (� Estimated Value of Project:
v (CANT: DO NOT WRITE BELOW THIS LINE
9
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cafes.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Cafes.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°” Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN ROUSE:-
'"! Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
>✓ 26 16- 60 0 C Zq
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel Calculation Date/time: 15:17, Tue, Jun 28, 2016
Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd
CF1 R -PRF -01
Page 1 of 7
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Manquero Remodel
04
06
02
Calculation Description Single Fam - Atch Gar -Sngl Stry
08 -
Energy Use (kTDV/fP-yr)
03
Project Location 53360 Montezuma Ave
Compliance Margin
Percent Improvement
04
City La Quints, California
06,
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version CBECC-Res 20134 (744)
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 266
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftp) 1537
16
Number of Zones 1
16
Slab Area (ft2) 0 -
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available No
20
Addition Slab Area (ft2) 0
210
1 ■ saw ■ ■ ■— ■ I
COMPLIANCE RESULTS gl-InnwnDEPT.
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
• 03 This building Incorporates one or more Special Features shown below
Registration Number Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744
�E�='�tew ta a —
JUN 2 9.2016
C F LA Q49ItM
J&% LOPMENT
C+�{♦� Report Generated at: 2016-06-28 15:18:17
ENERGY USE SUMMARY
04
06
06
07
08 -
Energy Use (kTDV/fP-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.10
0.65
2.45
79.0%
Space Cooling
142.50
114.93
27.57
19.3%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
24.83
24.83
0.00
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
170.43
140.41
30.0
17.8%
Registration Number Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744
�E�='�tew ta a —
JUN 2 9.2016
C F LA Q49ItM
J&% LOPMENT
C+�{♦� Report Generated at: 2016-06-28 15:18:17
i
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016
Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ceiling has high level of insulation
CFI R -PRF -01
Page 2 of 7
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• —None —
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
• — None —
Domestic Hot Water System Verifications:
• — None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for fighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDVtf2-yr)' 236.68 206.66 30.02 12.7%
' Includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Manquero Remodel
1537
1
3
1
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
'Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House - One Zone
Conditioned
HVAC System - Existing
1537
8
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance _ Report Version - CFiR-04072016-744
HERS Provider:
Report Generated at: 2016-06-28 15:18:17
J
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016
Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd
CFI R -PRF -01
Page 3 of 7
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
01
02
03
04
06
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (f:2)
Window & Door
Area (W)
Tilt
(deg)
Status
Verified
Existing
Condition
Bath -Storage N Wall
Whole House - One Zone
Ext Wali Assy - R13+1 EPS
356
Left
168
6
90
Existing
No
BED2 - N
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
356
Left
128
0
90
Existing
No
BED2 - E
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
86
Bads
96
20
90
Existing
No
MBATH-E
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
86
Bads
64
4.8
90
Existing
No
MSTRBED - E
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
86
Bads
112
10
90
Existing
No
LIVING -S
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
176
Right
136
0
90
Existing
No
KITCH - S
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
176
Right
80
0
90
Existing
No
KITCHEN -E
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
86
Bads
184
40.5
90
Altered
N/A
FAMILY - W
Whole House - One Zone
Ext Wall Assy - R13+1 EPS
266
Front
96
40.5
90
Altered
N/A
LIVING - W
Whole House - One Zone
Ext Wall Assy - RI 3+1 EPS
266
Front
144
81
90
Altered
N/A
MSTRBED-S
Whole House - One Zone
Ext Wali Assy - RI 3+1 EPS
176
Right
112
40.5
90
Altered
N/A
Ceiling (below attic) 1
Whole House - One Zone
Ceiling Assy - Existing
1537
Existing
No
Garage -E
Garage
Ext Wall Assy - R13+1 EPS
176
Right
160
0
90
Existing
No
Garage - N
Garage
Ext Wall Assy - R13+1 EPS
86
Bads
160
0
90
Existing
No
Garage -S
Garage
Ext Wall Assy - R13+1 EPS
176
Right
100
0
90
Existing
No
Int Com Wall - Fam Rm
Garage»Whole House - One
Zone
T24-2008 IntWall 2x4 16oc
R13
160
0
Existing
No .
Int Com Wall - Kitch
Garage»Whole House - One
Zone
T24-2008 IntWall 2x4 16oc
R13
64
0
Existing
No
Ceiling (below attic) 2
Garage
Garage ceiling
400
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emlttance
Barrier
Cool Roof
s
Condition
Attic
Asphalt Shingle Roof
Ventilated
3
0.1
0.85
Yes
No
Enigstl
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-06-28 15:18:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel Calculation DatefTlme: 15:17, Tue, Jun 28, 2016
Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd
CFI R -PRF -01
Page 4 of 7
WINDOWS
01
02
03
04
06
06
07
08
09
10
11
Name
Surface (Orientation- Azimuth)
Width(ft)
Height (ft)
Multlplle
r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Bath -N -1
Bath -Storage N Wall (Left -356)
—
—
1
6.0
0.32
0.25
Insect Screen (default)
Existing
No
BED2-E-2
BED2 - E (Back -86)
—
—
1
20.0
0.38
0.35
Insect Screen (default)
Existing
No
MBATH-E-3
MBATH-E (Back -86)
—
—
1
4.8
0.38
0.35
Insect Screen (default)
Existing
No
MBED-E-4
MSTRBED - E (Back -86)
—
—
1
10.0
0.38
0.35
Insect Screen (default)
Existing
No
DOORS
01
02
03
04
05
01
02
03
04
06
06
Name
Side of Building
Area (f:2)
U -factor
Status
Verified Existing Condition
KITCH - DFDoor - 6
KITCHEN -E
40.5
0.28
New
No
FAMILY - W DFDoor -9
FAMILY - W
40.5
0.28
New
No
LIVING -W- DFDoor-8
LIVING - W
40.5
0.28
New
No
LIVING -W DFDoor - 7
LIVING - W
40.5
0.28
New
No
MBED - DFDoor -5
MSTRBED-
40.5
0.28
New
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Sheathing/ Insulation: R4 Sheathing
Ext Wall Assy = R13+1 EPS
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.053
Exterior Finish: R4 Synthetic Stucco
• Cavity/Frame: no insul. /2x4 Top Chrd
20 Top Chord of Roof Truss c@ 24
Roof Deck: Wood Siding/sheathing/decking
Asphalt Shingle Roof
Attic Roofs
Wood Framed Ceiling
In. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Ceiling Assy - Existing
attic)
Wood Framed Ceiling
2x4 ® 16 in. O.C.
R 42
0'.023
Over Floor Joists. R-32.9 insul.
• Inside Finish: Gypsum Board
T24-2008 IntWall2x4 16oc
Cavity/Frame: R -13/2x4
R13
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
Ceilings (below
Inside Finish: Gypsum Board
Garage ceiling
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
none
0.472
Cavity/ Frame: no insul. /2x4
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version,- CFiR-04072016-744 Report Generated at: 2016-06-28 15:18:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel
Calculation Description: ALERATION - Compliance Report
Calculation Date/Time: 15:17, Tue, Jun 28, 2016
Input File Name: Manquero Remodel-160527.ribd
CFI R -PRF -01
Page 5 of 7
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW System -Existing Equip
DHW
Standard
Water Heater -Existing Equip
1
- none -
Existing
No
WATER HEATERS
01
02
03
04
OS
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
Water Heater -Existing Equip
Electric Resistance
Small Storage
50
0.97 EF
7000 -watts
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
as
06
07
Name.
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW System -Existing Equip
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Type
HSPF/COP Cap 47 Cap 17
Heating System
Cooling System
SplitHeatPump - Central split heat
7.2
44000
40000
12
10.42
pump
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC Fan
HVAC System -
Heat Pump Heating
Heat Pump
Yes
Heat Pump
Yes
Distribution
System
1537
Existing
No
Existing
and Cooling System
-Extg Equip
-fig Equip
System - Exstg
-Exstg
Equip
HVAC - HEATING SYSTEMS: Heat Pumps
01
02
03 04 06
06 07
Heating
Cooling
Name
Type
HSPF/COP Cap 47 Cap 17
SEER EER
Heat Pump -Extg Equip
SplitHeatPump - Central split heat
7.2
44000
40000
12
10.42
pump
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-06-28 15:18:17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel Calculation Date/Time: 15:17, Tue, Jun 28, 2016
Calculation Description: ALERATION - Compliance Report Input File Name: Manquero Remodel-160527.ribd
CF1 R -PRF -01
Page 6 of 7
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verlfled_Exlsting_
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
C6ndltlon*7
J
Verification
Distribution System -
Ducts located in attic
Existing (not-
4.2
Attic
Attic
None
Existing
No
N/A
Exstg
specified)
IAQ (indoor Air Quality) FANS
01 02 03 04 06
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
Whole House Fan 0 0.1 1
PROJECT NOTES
1. EE Fenestration Upgrade - Removal & Replacement
2. Additional alterations are cosmetic
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-06-28 15:18:17
' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Manquero Remodel
Calculation Description: ALERATION - Compliance Report
Calculation Date/Time: 15:17, Tue, Jun 28, 2016
Input File Name: Manquero Remodel-160527.ribd
CFIR-PRF-01
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 17
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Docum tati Ai e,
W
6 LC-,Sli
1/'
711 1
Company:
Signa re D te:
Address: l
�.o . Z
�
CE:A/HE S Ce ification Identificatio If applicable):
City/State2IF/� ^�
64
Phone:`
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design Identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications Identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Company:
Date Signed:
Address:
License:
City/State/Zip:
Phone:
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-06-2815:18:17
MASONITE — CERTIFIED THERMAL PERFORMANCE DATA FOR MANQUERO FIBERGLASS DOORS
CUSTOMER NAME: Anthony Manquero ADDRESS: 12344 Either Rd La Quinta,Ca.
PURCHASE ORDER NO.: ORDER DATE:
Detailed Product Ratings
MamCxtu2r: Nas 1. tme U-1 Corp rvaon
Send Name: N!"onite Fftemless sin Dam
OpenrurTyPe: e05
Atr leaea9e: .0.3
Key:
Click the Colum headers to son the data acardinq to the cotumn header.
A dash = In a mthly Cal— (SHGC IVr) W kates deet there are no NERC CemM.d values fm plat htlhMual proetdt.
CPD#
Group ID
Manufacturer Product Code
Frame/Sash
Type
U -factor
SHGC
VT
Condensation
Resistance
STN -K-29-33457-00001
1
S C540 -CL N FL W/N
WD/NA
0.28
0.17
0.31
-1
Glazing Layers
Low -E
G Widths
Spacer
Gap Fill
Grid
Divider
Tint
2
0.03664505(2)1
0.749998
Al -D
ARG/AIR 90/10
N
-1
CL
CERTIFICATION OF ARGON FILL
Michael,
The snap shots shown below illustrate the actual certification number and label placed on the product
during the manufacturing process. As you mentioned in your email our thermal performance sheets
need to be updated to include the 0.02 (Btu/h-ft2-F) non -thermal sill add-on rating option. The outswing
door unit ordered utilizes this sill add-on option which makes the over unit performance 0.28(U-
factor)/0.17(SHGC). I hope this information is helpful.
Based on Stacey's comment below this particular unit is assembled with LowE Argon filled. Our plant
confirmed IowE argon will be used in this order.
Thank You.
Tank Reid
Customer Service Manager - East Coast
the dutiful door -
P: 877-431-3667 1 F: 866-838-1267 1 www.masonite.com I saceves@masonite.com
X�ih'
TO WIN!
MASONITE - CERTIFIED THERMAL PERFORMANCE DATA FOR MANQUERO FIBERGLASS DOORS
MANUFACTURERS PERFORMANCE CERTIFICATION LABEL
Fiberglass Entry & Patio Door with
Outswing or ADA Sill STN -K-29*
ENERGY PERFORMANCE RATINGS
U -Factor (Btuft-tJ-'F) / Solar Heat. Gain Coefficient (SHGC)
INDIVIDUAL OPTION NUMBER
PRODUCT DESCRIPTION
DEFAULT FRAME"
1/4 Lite
5410 in`
1/2 Lite
5900 In,
3/4 Lite
51100 in
Full Lite
>1100 in'
Decorative IG
0.22/0.08
0.25/0.15
0.28/0.20
0.31/0.27
(Glass Type 0)
23582-00001
23579-00001
23580-00001
23581-00001
-Decorative IG
with Low-E/Argon
N/A
N/A
0.24/0.18
0.27/0.24
(Glass Typo Iq
23628-00001
23629-00001
Blinds Clear
Triple Pane
N/A
0.23/0.14
N/A
0.28/0.26
36216-00001
36217-00001
Blinds Low -E Tripie
Pane with Grids
N/A
0.22/0.10
N/A
0.26/0.19
36222-00001
36223-00001
Blinds Dual
Pane Clear
N/A
0.29/0.19
0.33/0.26
0.38/0.34
(Glass Typo TB)
32947-00001
32948-00001
32949-00001
-Blinds Dual
Pane Low -E
N/A
0.26/0-10
0.28/0.13
0.32/0.17
(Glass Type GB)
33179-00001
33180-00001
33181-00001
Blinds Dual
Pane Low -E
N/A
0.27/0.16
0.30/0.21
0.34/0.28
(0ass Type MB)
33171-00001
33172-00001
33173-00001
- Argon Dual
Pane 1°
Pane 1
N/A
0.24/0.10
0.26/0.13
0.28/0.17
(Glass Type D)
33455-00001
33456-00001
33457-00001
-t ow- Dual
Pane 1" with
1" w th Grids
N/A
0.24/0.09
0.26/0.12
0.28/0.15
(Glass Type D)
33527-00001
33528-00001
33529-00001
Low -E Dual Pane 1"
0.22/0.09
0.26/0.16
0.29/0.21
0.32/0.28
(Class Type M)
33410-00001
33411-00001
33412-00001
33413-00001
Low -E Dual Pane
Grids 1'
0.22/0.08with
0.26/0.14
0.29/0.19
0.32/0.25
(Glas3 Type M)
33482-00001
33483-00001
33484-00001
33485-00001
Low -E Dual
'Pane 1'
0.22/0.05
0.25 / 0.10
0.27/0.13
0.30/0.17
(Glas3 Type G)
33418-00001
1 33419-00001
33420-00001
33421-00001
LowDual Pane
1' with Grids
0.22/0-05
0.25/0.09
0.27/0.12
0.30/0.15
iGtass Type G)
33490-00001
33491-00001
33492-00001
33493-00001
Clear IG 1/2'
0.24/0.10
0.30/0.19
0.34/0.26
0.39/0.34
(Glass Type 7)
33394-00001
33395-00001
33396-00001
33397-00001
Clear with Grids 1/2"
0.24/0-09
0.31/0.17
0.35/0.22
0.41 / 0.30
(Class Typo T)
33406-00001
33407-00001
33408-00001
33409-00001
Clear IG 1"
0.24/0.10
0.29/0.19
0.32/0.26
0.37/0.34
(Gla33 Type T)
33386-00001
33387-00001
1 33388-00001
33389-00001
Clear With
Grids 1
1"
0.24/0.09
0.29/0.17
0.32/0.22
0.37/0.30
(Class Type T)
33398-00001
33399-00001
33400-00001
33401-00001
Low -E Vent Lite
N/A
0.25/0.07
N/A
N/A
(Glass Type G)
36723-00001
Clear Vent Lite
N/A
0.28/0.12
N/A
NIA
(Glass Type T)
36722-00001
Flush or Embossed
(Opaque)
0.17/0.01
1 8 58 5-00001
Air Loakage 50.3 cf Wft'
t.
The Home Depot Special Order Quote
Customer Agreement M H6630-3883
huh, Printed Date: 5/16/2016
Customer Information
Store Information
Name
ANTHONY MANQUERO
Store Number 6630
Address
5927 CERRITOS AVE
Address 79900 HIGHWAY 111
LONG BEACH, CA 90805
LA QUINTA, CA 92253
Primary Phone
562-426-4026
Associate ADRIANA
Secondary Phone
562-426-4026
Item # Item Description Room Location Unit Price Qty Total Price
www.HomeDepot.com Page 1 of 4 Printed By: ADRIANA Date Printed: 5/16/20161:04 PM
100-1 Masonite Smooth Double Prehung 74 x 80.375
RO Width = 74.75
RO Height = 80.875
Call Width = 72"
Call Height = 80"
Width = 74
Height = 80.375
Show only Energy Star products = Yes - Show only
Energy Star
Handing -Swing = Double Right Hand Outswing
Swing (for Energy Star) = Outswing
Panel Thickness = 13/4"
Glass Type = Clear Glass No Grille
Glass Shape = Full Lite Rectangle
Door Style = Full Lite Rectangle
Grain Texture = No Texture (Smooth)
Material = Belleville Smooth Fiberglass
Glass Size = 122 - 22x64 rect
Glass Style = 1 Lite
Glass Caming = No Caming
Low -E = Yes - Soft Coat
Door Finish Type = Unfinished
Exterior Color= Unfinished
Interior Color = Unfinished
Jamb Width= 4 9/16"
Jamb Type = Primed Wood
Matching Brickmould = No
Jamb Finish Type = Unfinished
Jamb/Brickmould Color= Unfinished
Handleset Style = None
Passive Door Handleset = No
Lock Prep Active Panel = 5 1/2" Double Bore
Lock Prep Passive Panel = Single Bore
Hinge Type = Standard Hinge for Fiberglass Door
Hinge Finish = Antique Black
Sill Type = Bumper Sill (matches Outswing door)
Sill Finish = Antique Black
Petdoor Installed = No
Mailslot Cutout = No
Peephole Installed = No
Is this door/sidelite Energy Star? = Yes
Is this unit Energy Star Certified? = Yes
Additional Services = None
Re -Order = No
Room Location = Back
SKU =47657S
Vendor Name = S/O STANLEY/MASONITE
Vendor Number = 60695971
Customer Service = 1-877-431-3667
Catalog Version Date = 5/2/2016
co� 5 $4,260.25
$724.27 $3,621.35
Save $638.90 (15%) until 5/18/2016
• S/O STANLEY/MASONITE-476575 Promotion until
5/18/2016
El
• www.HomeDepot.com Page 2 of 4 Printed By: ADRIANA Date Printed: 5/16/20161:04 PM
Q
q ESTABLISHED IN 1918 AS A PUBLIC AGENCY
G�
COACHELLA VALLEY WATER DISTRICT
POST OFFICE BOX 1058 • COACHELLA, CALIFORNIA 92236 • TELEPHONE (760) 398-2651 • FAX (760) 398-3711
DIRECTORS: OFFICERS:
JOHN W. McFADDEN, PRESIDENT STEVEN B. ROBBINS,
PETER NELSON, VICE PRESIDENT GENERAL MANAGER -CHIEF ENGINEER
TELLIS CODEKAS JULIA FERNANDEZ, SECRETARY
RUSSELL KITAHARA DAN PARKS, ASST. TO GENERAL MANAGER
PATRICIA A. LARSON REDWINE AND SHERRILL, ATTORNEYS
Gene Caswell
53-660 Avenida Montezuma
La Quinta, California 92253
Dear Mr. Caswell:
Subj ect
Aguust 26, 2003
RECEIVED
AUG 2 9 2003
PUBLIC WORKS
53-265 Avenida Juarez
Account No. 606123,170.0.4
File: 1112.
In response to your inquiry, all sewer requirements for the above -referenced
property have been met. It will be the homeowner's responsibility to
connect their pipeline to the sewer lateral.
If you have any questions please contact Rosie Anacleto, Customer Service
Representative, extension 2420.
Yours very truly,
4,,;S
eve 4Robbnsi
eneral Manager -Chief Engineer
RIA:ra
bc: City of La Quinta
Post Office Box 1504
La Quinta, California 92253
TRUE CONSERVATION