Loading...
06-0272 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 06-00000272 53680 AVENIDA MONTEZUMA 774-101-008-15 -000000- ADDITION - RESIDENTIAL COVE RESIDENTIAL 27456 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 1 Section 7000) of Division 3 of the Business and Professionals Code, and my License is in License Class: 13 License No.:. 855557 Date: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by a pplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). lid 1 I, as owner of the property, am eirwrely contracting with licensed contractors to construct the project (Sec. (� 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, appd who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License%Law.). �f A (_ 1 I am exempt under Sec. , B.&P.C. r thi/reason/ /e: I hereby affirm under penalty of perjury that tKere is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: HERNANDEZ MICHAEL 53680 AVENIDA MONTEZUMA LA QUINTA, CA 92253 Contractor: ANGLES CONSRUCTION 45175 PANORAMA DRIVE PALM DESERT, CA 92260 (760)568-6064 Lic. No.: 855557 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/14/06 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0002290030801 410 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any mMshouldecome meWkers' ers' co pensation laws of California, nd agree that, ubjcompe ation pr visions of Section `�, / 700 of the Lahwe pr isions. ✓ / U �icDate:WARN G: FAILURE TO SECUMPEGE IS UNLA UL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abov ?information is orre . I agree tp comply Avith all city and co my o dinances and state laws relating to building nstru ion, d ere y authoriz represe fives of this cou ty to fn upon upon the above-mentioned proper fo nspe ion p rpo as D / vature (Applicant or Agent): Application Number . . . . . 06-0.0000272 Permit . . . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 271.50' Plan Check Fee 176.48 Issue Date Valuation . . . . 27456 'Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 252.00 3.00 6.5000 ---------------------------------------------7------------------------------ THOU BLDG 25,001-50,000 19.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 31.80 Plan Check Fee 7.95 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 480.00 .0350 --------------------'-------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 16.80 Permit . . . . . MECHANICAL Additional desc . Permit Fee . . . . 46.00 Plan Check Fee 11.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 13.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 63.00 Plan Check Fee 15.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 7.00 6.0000 EA PLB FIXTURE 42.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 480 sq. ft. ADDITION.WITH REROOF LQPERI%IIT Application Number . . . . . 06-00000272 ----------------------- Special Notes and ----------- Comments . --------------- ------------- -------------- COMPLETE HOUSE.March 14, 2006 7:38:01 AM jjohnson ----------------------------------------------------'----------------------- Other Fees . . . . . . . . ENERGY REVIEW FEE 17.65 STRONG MOTION (SMI) - RES 2.74 Fee summary ----------------- Charged ---------- Paid -------------------- Credited ---------- Due Permit Fee Total 412.30 .00 .00 412.30 Plan Check Total 211.68 .00 .00 211.68 Other Fee Total 20.39 .00 .00 20.39 Grand Total 644.37 .00 .00 644.37 LQPERAIIT P.O. BOX 1504 APPLICATION ONLY Buildingv 78 495 CALLE TAMPICO Address. l (V"' NTA, CALIFORNIA 92253 BUILDING: TYPE CONST. OCC. GRP. Mailing'2� Address �� . (oft � � t �,��. P. VM A.Number / 6 City Zi Tel._ Legal Description �2H Contractor Project Description A,r2 Address City Zip Tel. S q• Ft. � No. No. Dw. Size tories units State Lic. & Classif. City Lic. # 7 J Arch., Engr., Des�I ped t/' 1� %..r en "s New ❑ Add Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT ddress Tel. .• l"15 irM� • fin" T 4 `' ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Const. Zip State Lic. # Electrical LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Date Owner Infrastructure WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE TOTAL REMARKS (This section need not be completed if the permit is for one hundred dollars (3100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: CONSTRUCTION LENDING AGENCY Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Rear Setback from Rear Prop.Line Lender's Name Lender's Address This is a buildingSide permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. Side Street Setback from Center Line Setback from Property Line p y I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. FINAL DATE INSPECTOR Issued by: Date Permit Signature of applicant Date Mailing Address Validated by: Validation: City, State, Zip WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code.65995 Et Seq. in the amount of $0.00 X 480 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Michael Hernandez Check No. Name on the check Telephone 771.6067 Funding Exempt By Dr. Doris Wilson Superintendent Fee collected =/? , Payment Recd I�p.pp Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), flis will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to rud4ro , the dat on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document'NOT VALID if Duplicated Embossed Original- Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting orufv CERTIFICATE OF COMPLIANCE Sc� Desert Sands Unified School District �. 70 47950 Dune Palms Road BERMUDADUNES /1i1 Date 3/14/06 La Quinta, CA 9225) N RANCHO MIRAGE INDIAN WELLS �r No. 28237 (760) 771-8515v� �i. PALM DESERT LA QUINTA J'3Q.INDIO .vJ Owner Michael Hernandez APN # 774-101-008 Address 53-680 Avenida Montezuma Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53680 Avenida Montezuma 480 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code.65995 Et Seq. in the amount of $0.00 X 480 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Michael Hernandez Check No. Name on the check Telephone 771.6067 Funding Exempt By Dr. Doris Wilson Superintendent Fee collected =/? , Payment Recd I�p.pp Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), flis will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to rud4ro , the dat on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document'NOT VALID if Duplicated Embossed Original- Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting I TITLE 24 REPORT . I Title 24 Report for: MR. MICHAEL ANGELO HERNANDEZ 53-680 AVENIDA MON T LA QUINTA, ACITY OF to QUINTA BUILDING & SAFETY DEPT - APP PT- APPRO ETON FOR CO DA Project Desig - . GABRIEL LUJAN & ASSOCIATES 45-175 PANORAMA DR. STE. A PALM DESERT, CA 92260 760-578-8545 Report Prepared By: ADRIANA GIL Adriana Gil 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 Job Number: ADY349-0106 Date: 5/30/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number: ADY349-0106 User Number: 5553 I TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 7 9 EnergyPro 4.1 by EnergySoft Job Number: ADY349-0106 User Number: 5553 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R _MR--M.1_CHAELANG.ELO_H.ERNAN.DEZ Total Conditioned Floor Area: 576 5130/2006 Project Title Existing Floor Area: n/a Date _5.3-6-8-0_AV_EN.I.DA-M-0 N_T_EZ.0 MA-LA_Q-UIN TA Raised Floor Area: 0 Project Address Natural Gas Slab on Grade Area: Building Permit # A_ d.r_iana Gil 4,608 (760) 404-7917 1.8 Documentation Author Wood_ Telephone Plan Check/Date _En.ecgP_r_o Compli ce Method 0__9.0 15 Climate Zone Wall_ Field Check/Date 1.51. TDV Energ Use Standard Proposed Compliance (kBtu/sf-yrf Design Design Margin _0.098- Space Heating 0.61 0.12 0.49 Space Cooling 70.99 68.22 2.77 Fans 10.73 11.88 -1.16 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 82.33 80.23 2.10 Building Type Standard: [X-] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: 2. ❑ Addition Total Conditioned Floor Area: 576 ft2 ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 (N) 0 deg Raised Floor Area: 0 ft2 Natural Gas Slab on Grade Area: 576 ft2 Fenestration: .01_A1.8 Average Ceiling Height: Area: 114 ft2 Avg. U: 0.47 Number of Dwelling Units: Ratio: 19.8% Avg. SHGC: 0.46 Number of Stories: BUILDING ZONE INFORMATION Azm. # of Thermostat Zone Name Floor Area Volume Units Zone Type Type .HVAC_Split_S.ystem 5.7.6 4,608 1...00_ Conditioned--Setback- OPAQUE SURFACES .01_A1.8 Insulation Act. -0.9=A21 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood_ 5.7.6- _0.025- _R=38_ _R=0..0_ 0_ 1.8 Wall_ Wood_ 3.9_ 0.0.9.8_ _R_1.3_ _R=0.0_ 0__9.0 Wall_ Wood_ 1.51. _0..0.9.8_ _R_1.3_ _R=0..0_ _9.0__9.0 Wall_ Wood_1_4.0- _0.098- -R_1.3- _R=0_0_ 1.80__90 8.0 ft 1.00 1 Vent Hgt. Area -2 -n/a Gains Condition Y / N Status JA IV Reference Location / Comments New .01_A1.8 House New -0.9=A21 House New -0.9=A29 House New .09=A21 House EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Pape:3 of 9 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R MR. MICHAEL ANGELO HERNANDEZ Project Title 5/30/2006 Date FENESTRATION SURFACES # Type Area LI -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments _'L Window F_ront_(N)_ -5.3.3_ _0.._4.70-NF_RC__0.4.6 2 Window Left (E_ 12.5 -NFRC. 0.470 NFRC 0_46 NFRC 0_ _9.0- New DEFAULT DBLP_ANE 90 90 New DEFAULT DBL PANE -House House 3 Window Left (g)_ 12.5 0.470 NFRC 0_46 NFRC 90 90 New DEFAULT DBL PANE House 4 Window Left Q_ 16.0 0.470 NFRC 0_46 NFRC 90 90 New DEFAULT DBL PANE House 5 Window Rear (S) 16.0 0.470 NFRC 0_46 NFRC 180 90 New DEFAULT DBL PANE House 6 Window Rear (S)_ 4.0 0.470 NFRC 0_46 NFRC 180 90 New DEFAULT DBL PANE House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt 1 Bug Screen 0.76 6.7 8.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 4.0 2.0 0 1 2.0 2.0 5 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 2.0 2.0 0. 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 576 3.50 28 0_98 0 26-A1 New House / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 64 None No Insulation 26-A1 New House EnergyPro 4.1 by EnergySeft User Number: 5553 Job Number: ADY349-0106 Page:4 of 9 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R MR. MICHAEL ANGELO HERNANDEZ Project Title 5/30/2006 Date HVAC SYSTEMS Location Heating Minimum Type Eff Cooling Type Minimum Condition Eff Status Thermostat Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct Condition R -Value Status Ducts Tested? HVAC Split System Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS RatedTank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE' (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: GABRIEL LUJAN & ASSOCIATES Address: 45-175 PANORAMA DR. STE. A PALM DESERT, CA 92260 Telephone: 760-578-8545 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: ADRIANA GIL Title/Firm: Adriana Gil Address: 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 Teleph Q; (7� 404-7917 ® li (sign cure) (date) (signature/stamp) (date) I EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Paae: 5 of 9 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R MR. MICHAEL ANGELO HERNANDEZ 5/30/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should.pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the .�cY-y.�F.— P1 JYJYIIbaYVll p11Y YW-11C11w11U11 . UUIIIILLUU. Plan Field The Roof "R-38 Roof (R.38.2x4.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 576 sqft Exposed Slab Floor, 3.50" thick at House HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- ap roved HERS rovider..in ('9:1'a d t t' Al 'f' p p g pprove es mg an or ver kation methods and must be reported on the CF -4R installation certificate. Plan Field The HVAC System "HVAC Split System " incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "York H1 RD018S06" includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:6 of 9 1 Mandatory Measures Summary: Residential (Page 1 of 2) ' MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 1 ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ ❑ apply to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply witf§ 151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and El N El CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ 0 ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. - ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. ❑ ❑X ❑ 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ ❑X ❑ insulation having an installed thermal resistance of R-12 or greater. ❑ ❑ ❑ 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ ❑ ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (") below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ R ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ Q ❑ dampers. ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ X❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑X ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑X ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ x❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1� 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:8 of 9 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MR. MICHAEL ANGELO HERNANDEZ 5/30/2006 --1 SYSTEM NAME FLOOR AREA HVAC Split System 576 HECKS Number of Systems I L 1=1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 111.1 Cooling System Output per System 20,400 Total Output (Btuh) 20,400 Total Output (Tons) 1.,7 Total Output (Btuh/sgft) 35.4 Total Output (sgft/Ton) 338.8 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.39 Airflow (cfm/Ton) 470.6 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,363 11,047 1,557 123 9,503 0 1,718 1,219 0 0 0 0 0 0 0 0 0 1,718 11219 14,482 1,557 York H1RD018S06 9,920 10,214 Total Adjusted System Output g g2o 10,214 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 64,000 64,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 68.5 of 68.5 of 145.6 of O Supply Air Ducts 7 Outside Air 0 cfm 144.1 of Supply Fan Heating Coil 800 cfm ROOMS 68.5 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 109.9 / 77.2 of 78.1 / 70.1 of 78.1 / 70.7 of 66.1 / 66.0 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 68.2 / 66.6 of 800 cfm 72.9% R.H. ROOMS 78.1/70.1 of 76.0 / 69.5 of Return Air Ducts -S4 EnergyPro 4.1 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:9 of 9