Loading...
06-1262 (AR)'P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 06-00001262 Property Address: 53680 AVENIDA MONTEZUMA APN: - 774-101-008-15 -000000- Application description: ADDITION - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 5491 Applicant:- Architect or Engineer: _4t�tVOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/05/06 Owner: MICHAEL HERNANDEZ 53-680 AVENIDA MONTEZUMA LA QUINTA, CA 92253 ------------- ----- ------------- -- LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 855557 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the - following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to'an owner of property who builds or improves thereon, and who.contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: — Lender's Address: LQPERMIT Contractor: p :APR ANGLES CONSRUCTION' �+ c PALMSDESERTT,CADRIVE 92 60 0 6 200(760)568-6064 Lic. No. 855557 LAQUit,TA — — — — — — — — — — — — — — — — — — WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will. maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0002290030801 _ I certify that, in the peOect a work for which is &pen II not employ any person in any manncom subje t wolaws of California; and agree that, •if I e - ject t rkersisions of Section 0 of the Labor wit co pl ith th Date: Applicant: OC WARNI G: FAILURE TO SECURE OMPENSATION ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER.TO CRIMTIES AND CIVIL FI ES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application become ull and void if work i not commenced within 180 days from date of issuance of such perm" or cessation o k 180 days subject permit to cancellation. / I certify that I have read this application and state that the abov 'hfor tion i torr agree to c ply with all city and coun o inances and state laws relating to build' g stru ion, d he authorize r esentatives of this coun t mer upon the above-mentioned prope to nspe ion p rp S. Date: Signature (Applicant or Agent): Application Number . . . . . 06-00001262 Permit . . . BUILDING PERMIT Additional desc•. Permit Fee 81.00 Plan Check Fee 52.65 Issue Date Valuation 5491 Expiration.Date 10/02/06 Qty Unit Charge Per Extension ' BASE FEE 45.0036.00 4.00 9.0000 THOU BLDG 2,001-25,000 7 ----------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 18.36 Plan Check Fee 4.59 Issue Date Valuation 0 Expiration :ate 10/02/06 Qty Unit Charge Per Extension BASE FEE 15.00 -------96_00--------__0350-----_-ELEC-NEW.RES - 1 OR 2 FAMILY 3.36 ---------------------- Special Notes and Comments -------------- REVISION TO PERMIT.#06-272. ADDITIONOF 96 SQ: FT. WHILE UNDER CONSTRUCTION.April 5, 2006 9:07:43 AM jjohnson -------------------------------------- . Other Fees ENERGY REVIEW FEE 5.27 STRONG MOTION (SMI) - RES .54 Fee summary. Charged Paid Credited -------- ---------- Due ---------- ---------- ---------- Permit Fee Total 99.36 .00 .00 99.36 Plan Check Total 57.24. .00 .00 57.24 Other Fee Total 5.81 .00 .00 5.81 Grand Total 162.41 .00 .00 162.41 LQPERMIT Bin # - -1 --Building Ci of La uinta 8Z Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sh et , P.rmit # Project Address: 3 — F Owner's Name:7�7 / A A. P. Number: Address: (j u c,/�/ Legal Description: Contractor: PSS Cc.:, n ppjf7 City, ST, Zip: Telephon : ? b0 Address: Project Description: (� City, ST, Zip: n AVP- f L j` Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: Constuption Type: 04cup V& Project type (circl ew AJP&ter Rep emo Sq. Ft.: # Sto 'es Units: ­74Telephone # of Contact Perso b �� Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING . RMIT FEES Plan Sets � r- r -, a Plan Check submitt d Item Amount Structural Calcs. Reviewed, ready for orrections Plan Check Deposit Truss Calcs. 2. d Called Contact Pers Plan Check Balance Construction Energy Calcs. Plans picked up Flood plain plan Plans resubmitted pd Mechanical Grading, plan' 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ir° Review, ready *for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Bin # City of La Quinta Building U Safety Division .Permit.# P.O. Box 1504, 78-495 Calle Tampico U Quinta, CA 92253 - (760) 777-7012 Building Permit Application aqdTracking heet Project Address:,Owner's Name:2--- A. P. Number: Address: U G City, ST, Zip: Legal Description: Contractor: Address:' Telephone: 7 --�. Project Description: City, ST, Zip: Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: Construction Type: Occupancy: State Lic. #: Project type (circle one): New. Add'n Alter Repair Demo Name of Contact Person: �((� l ^� Sq. Ft.: #Stories: -T# Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE tl Submittal Plan Sets Req'd Recd TRACMG Plan Check submitted PERMIT FEES Plan Check Deposit Plan Check Balance Amount Structural Calcs. Reviewed, ready for corrections Truss Calcs. Called Contact Person Energy Calcs. Plans picked up Construction FGrading.plan' Flood plain plan Plans resubmitted -- Mechanical 2nd Review, ready for come ions/issue Electrical Subcon tactor. List Called Contact Person Plumbing S.M.I. Grant Deed Plans picked up H.O.A. Approval:. Plans resubmitted Grading Developer Impact Fee A.LP.P. IN HOUSE:- ''' Review, ready for correctionstissue Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees /)� Total Permit Fees 7 ��;q T-Vf 4 4 a" P.O. Box 1504 . 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 Finance Department, Please Collect The Following Fees For The Services Rendered HTE APPLICATION No. 06-1262 PROJECT: HERNANDZ ADDRESS: 53-680 AVE. MONTEZUMA CUSTOMER: ANGELES CONST. SERVICES RENDERED: REVISIONS WHILE UNDER CONSTRUCTION ADDITIONAL PLAN CHECK. TITLE -24 REVISIONS. Fees Plan Review: ............1 HOURS @ 35.00 PER HR ......................... $ 35.00 Date: 06/12//06 Initials: JLJ TOTAL FEES NOW DUE:............ ......................$ 35.00 i f At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 576 S.F. or $1,514.88 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Wells Fargo - Michael Hernandez Check No. 0737703869 Name on the check Telephone 71.6067 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exemp y Sharon MCGllvrey Payment Recd $o.00 $1,514.88 Dver/Uer Signature 4.1 ; 1 NOTICE: Pursuant to Government Code Section 688290)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting CERTIFICATE OF COMPLIANCE Desert Sands Unified School Districto 47950 Dune Palms Road BERMUDA DUNES r- Date 4/5/06 La Quinta, CA 92253 RANCHO MIRAGE CJ r INDIAN WELLS No. 28350 (760) 771-8515 DESERT �Y PALML OUINTA �y OINDIG 1� Owner Michael Hernandez APN # 774-101-008 Address 53680 Avenida Montezuma Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53680 Avenida Montezuma 576 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 576 S.F. or $1,514.88 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Wells Fargo - Michael Hernandez Check No. 0737703869 Name on the check Telephone 71.6067 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exemp y Sharon MCGllvrey Payment Recd $o.00 $1,514.88 Dver/Uer Signature 4.1 ; 1 NOTICE: Pursuant to Government Code Section 688290)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting TITLE 24 REPORT Title 24 Report for: MR. MICHAEL ANGELO HERNAND 53-680 AVENIDA MONTEZ Tyff(- Project LA QUINTA, CA BUILDDEPT. A FO DAT Designer: GABRIEL LUJAN & ASSOCIATES 45-175 PANORAMA DR. STE. A PALM DESERT, CA 92260 760-578-8545 Report Prepared By: ADRIANA GIL Adriana Gil 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 Job Number: ADY349-0106 Date: 1/3/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: ADY349-0106 User Number: 5553 1 =1.1 TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3, 7 9 10 EnergyPro 4.0 by EnergySoft Job Number: ADY349-0106 User Number: 5553 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R -Mt1-M1_C-HAELA_ N_GELO HERNANDEZ [] Single Family ❑ Addition Total Conditioned Floor Area: 480 11-312006 Project Title ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a Date -_3=6-80-&VEN1DANL0-NIEZUMA-LA Q_UJNTA (North) 0 deg Raised Floor Area: Project.Address ft2 Fuel Type: Building Permit # A_ dri.3ria_Gil 480 ft2 (760)-4-04-7917 Documentation Author 8.0 Telephone Plan Check/Date _Ene.r_q- CompliMice Method Avg. U: 0.34 Number of Dwelling Units: 15 Climate Zone Field Check/Date 23.8% Source Energy Use Standard Proposed Compliance BUILDING ZONE INFORMATION # of (kBtu/sf-yr) Design Design Margin Floor Area Volume Units Zone Type Space Heating 0.62 2.40 -1.79 Space Cooling 75.63 .49.99 25.64 OPAQUE SURFACES Fans 11.45 7.65 3.80 Type Frame Domestic Hot Water 0.00 0.00 0.00 Roof Wood- Pumps 0.00 0.00 0.00 Totals 87.69 60.04 27.65 Percent better than Standard: Wall_ Wood_ 1.51. _0.0.7.2. 31.5% House Building Type: [] Single Family ❑ Addition Total Conditioned Floor Area: 480 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (North) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 480 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 114 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Ratio: 23.8% Avg. SHGC: 0.28 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -Split -System 480 -3,8.40 1A0_ Sleeping _SleepingStat_ 2'-n/,a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Roof Wood- 4.80__0_028__R_38 -_R-0...0_ 0_ 1.8 IN ❑New .02=A28 House Wall_ Wood_ 1.0-7-0 072__R_1.3__R_4.5_ 0_ 9.0 IXC [:]New -0.9=A21 }louse Wall_ Wood_ 1.51. _0.0.7.2. -R_1.3_ _R-.5_ _9.0- 9.0 X ❑N.ew .0.9_A21 House Wall_ Wood- 14.0_ -0._072. -RA .3_ _R-4.-5_ 1.8.0__9.0 � ❑New .0.9_A21 House ❑ ❑ 0 ❑ u u w F1 F-1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ -- ❑ ❑ F-1 F-1 F-1 F-1 El El Run Initiation Time: 01/03/06 22:57:15 Run Code: 1136357835 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:3 of 10 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R MRi MICHAEL ANGELO HERNANDEZ 1/3/2006 Project Title Date FENESTRATION SURFACES # Type Area 1.1 -Factor" SHGC2 True Azm. Cond. Tilt Stat. Glazing Type Location/ Comments J_ WindovwEtont 2 Window Left (North)_5.3_3- East . 12.5 _0.340 -NERC. _0.28 -NERC. 0.340 NFRC 0_28 NFRC 0_ 90 _9.0- NewB.ELTERB.ILT VinyJlow-E_ 90 New BETTER BILT Vinyl low E _H.o.use House 3 Window Left East 12.5 0.340 NFRC 0_28 NFRC 90 90 New BETTER BILT Vinyl low E House 4 Window Left East 16.0 0.340 NFRC 0_28 NFRC 90 90 New BETTER BILT Vinyl low E House 5 Window Rear South) 16.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BILT Vinyl low E House 6 Window Rear (South) 4.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BILT Vinyl low E House 4.0 2.0 0. 2.0 2.0 5 Bug Screen 0.76 4.0 4.0 1. Indicate source either from NFRG or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.7 8.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 4.0 2.0 0. 2.0 2.0 5 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 2.0 2.Q 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments 64 None No Insulation 26-A1 New House Run Initiation Time: 01/03/06 22:57:15 Run Code: 1136357835 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:4 of 10 G rtificate Of Compliance : Residential (Part 3 of 3) CF -1 R MRS MICHAEL ANGELO HERNANDEZ 1/3/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location. Type Eff Type Eff Status Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Location Heatir HVAC Split System Ducted Duct Duct ` Condition Cooling Location R -Value Status Ducted Attic 8.0 New Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Ducts Tested? No WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ftL Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firr?.: GABRIEL LUJAN & ASSOCIATES Address; 45-175 PANORAMA DR. STE. A PAL CA 92260 Telephong:7 -578-8545 Lic. #: �+ (signature) � 7d da Enforcement Agency Name: TitlJFirm: Address: Telephone: I Documentation Author Name: ADRIANA GIL Title/Firm: Adriana Gil Address: 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 Telepho e:(760) 404-7917 G _&0 3 (signat re) (date) (signature/stamp) (date) I EnergyPro 4.0 by EnergySoft User Number: 5553 . Job Number: ADY349-0106 Paoe:5 of 10 1 Certificate Of Compliance: Residential (Addendum) CF -1 R MRS."MICHAEL ANGELO HERNANDEZ 1/3/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the aueyuacy o1 LIM special rusuncauon anu uocumencacuon suommeo. Plan Field The HVAC System "HVAC Split System " must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- _. __...� ___ _ ...., ..... .........,.�...� �r„�.�,...��.���..� I nstall ation certificate. Plan I Field EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Paae:6 of 10 1 9 'Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑X ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. Q ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox 0. ❑ ❑ b. outside air intake with damper and control, flue damper and control 0 ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑X ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual ❑x ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. Q ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor Q ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ElE]CF-6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑X ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑x ❑ ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑X ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 0 ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑X ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑X ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑X ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A: Q ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, Q ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed Q ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. 0 ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:7 of 10 -,Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, Q ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements .of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than X❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive X❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑X dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. I § 114: Pool and Spa Heating Systems and Equipment ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the 0 ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. El ❑ ❑ b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑X ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table © ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑X ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. §�150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. Q ❑ ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are X❑ ❑ ❑ controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are X❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the X❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. X❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:8 of 10 dential Kitchen Lighting Worksheet MR --MICHAEL ANGELO HERNANDEZ 1/3/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires. that are high efficacy luminaires as defined in Table'150-C. Luminaires that are not high efficacy must be switched separately.. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. 13 High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts Yes No x = or Yes No. x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 0 B: 0 COMPLIES IF A >_ B YES 5-d NO ❑ ;1 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Paoe:9 of 10 1I4'VAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MR. MICHAEL ANGELO HERNANDEZ 1/3/2006 SYSTEM NAME FLOOR AREA HVAC Split System 480 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 133.3 Cooling System Output per System 20,400 Total Output (Btuh) - 20,400 Total Output (Tons) 1.7 Total Output (Btuh/sgft) 42.5 Total Output (sgft/Ton) 282.4 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.67 Airflow (cfm/Ton) 470.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 24.0 OF 69.0 OF Outside Air t V r 0 cfm f Supply Fan 800 cfm 69.0 OF TOOLING SYSTEM 09.9 / 77&2 OF Outside Air 0 cfm 77_16 / 69.7 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 11COILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible _11,482 1,431; 9 482 York H1RD018S06 9,842 10,166 64,000 Total Adjusted System Output g g42 10,166 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tei 69.0 OF ® 146.0 °F Heating Coil Tem of Heating Pea �% Return Air Ducts 4 77.6 / 69.7 OF 77.6 / 70.3 OF 65.8 / 65.6 OF Supply Fan 800 cfm Cooling Coil h Return Air Ducts `i Supply Air Ducts 145.0 OF ROOMS 70.0 OF Supply Air Ducts 67.4/66.1OF 72.0% R.H. ROOMS 76.0 / 69.3 OF F—EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY349-0106 Page:10 of 10