04-5496 (SFD)
q L p `x,,oiibr P.O. Box 1504"�---,z 78-495 GAL E Tnn�Pre ��� LA QUZ , C;ALIFORNIA 92253 60a" BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760) .777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Application Number . . . . . 04-00'005496 Date 9/15/04 Property Address . . . . . . 53840 AVENIDA MONTEZUMA APN: 774-141-006-18 -000000- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . COVE RESIDENTIAL Application valuation . . . . 125036 Owner Contractor ------------------------ MARK TUVELL ------------------------ -'MTB INC. 50-855 WASHINGTON ST #149 50855 WASHINGTON ST STE 149 LA QUINTA CA 92253 LA QUINTA CA 92253 (760) 272-6044 WCC: STATE FUND WC: 1795095-2004 08/01/05 CSLB: 838089 05/31/06 CCC: B ------ Structure Information 2028 SQ. FT. SFD ----- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 444.00 PATIO SQ FTG 25.00 NUMBER OF UNITS .1.00 ----------------------------------------------------------------------------- FIRST FLOOR SQ FTG 2028.00 Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 730.50 Plan Chetk Fee 474.83 Issue Date . . . . Valuation . . 125036 Qty Unit Charge Per. Extension BASE FEE 639.50 26.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 91.00 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 109.86 Plan Check Fee 27.47 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension P.G. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: 04-- S'� 9,1j Applicant: C O X-MRACTo R Applicant's Mailing Address: Architect or Engineer: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License QClass ..[.� / License No. �� COSI Date / —L2_ -o Y --Contractor /4- /l *1/ a OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' comppensation insurance carrier and olicy number ar Carrier TI�7T� (`' V N P Policy Number / cy nu q Z p p _ I certify that, in.the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date `� ?Q_ y Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address ACKNOWLEDGEMENTAPPLICANT IMPORTANT Application is hereby made to the Director of Building and Safety for permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction. and hereby authorize representatives of this county to enter on the above -mention erty for inspection purposes. Date / �Z Z- �� y Signature (Applicant or Agent): �� Page 2 Application Number . . . . . 04-00005496 Date 9/15/04 Qty Unit Charge Per Extension BASE FEE 15.00 2028.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 70.98 444.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.88 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 --------------------------------------------------------------- Permit . . ------------- . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 65.50 Plan Check Fee 16.38 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 .9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 ---------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . --------------------- . . . PLUMBING --------------------------------- Additional desc Permit Fee . . . . 153.00 Plan Check Fee 38.25 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 -------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments -------------------- 2028 SP SFD. PERMIT DOES NOT INCLUDE O Fee summary Charged Permit Fee Total 1073.86 Plan Check Total 556.93 Other Fee Total 2564.98 Grand Total 4195..77 Paid Credited Due ---------- ---------- ---------- .00 .00 1073.86 .250.00 .00 306.93 .00 .00 2564.98 250.00 .00 3945.77 Page 3 Application Number . . . . . 04-00005496 Date 9/15/04 ---------------------------------------------------------------------------= Special Notes and Comments POOL/SPA/BLOCK WALLS. A SEPERATE PERMIT & INSPECTION IS REQUIRED BY PUBLIC.WORKS DEPARTMENT FOR DRIVEWAY APPROACH. 2001 CBC. -------------------------------------------'--------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 47.48 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225..00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 COVE PRECISE PLAN FEE 100.00 .STRONG MOTION (SMI) - RES 12.50 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Permit Fee Total 1073.86 Plan Check Total 556.93 Other Fee Total 2564.98 Grand Total 4195..77 Paid Credited Due ---------- ---------- ---------- .00 .00 1073.86 .250.00 .00 306.93 .00 .00 2564.98 250.00 .00 3945.77 Building f"3 _9111Al, Address •V) 9 e tv � � P.O. BOX 1504 APPLICATIONONLY- /�78-495 CALLE TAMPICO d�(QUINTA, CALIFORNIA 92253 Mailing l Address �0 iii ����%�10✓J S7 •/ji Address State Lic. City I & Classif. I Lic. # Designer Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ori mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Lo u l✓ �f�°�'� i BUILDING: TYPE CON,, fST. CC,.aGRP. A.P. Number -7 7 Legal Description Project Description �� '✓ ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date PINK = FINANCE Sq. Ft. Zo 2- � Size No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT 0 p Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading 1 r; pm Driveway Enc. W cJ Infrastructure ][ rr�nr FltdA:JCE n .p'r TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date PINK = FINANCE '11w;"_� Date 9/21/04 No. 26447 Owner Mark Tuvell Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units EEL- '__fn o. Q BERMUDA DUNES Cn RANCHO MIRAGE INDIAN WELLS PALM DESERT .y LA QUINTA INDIO l� A 774-141-006 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53840 Avenida Montezuma 2028 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 2,028 S.F. or $4,542.72 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/1 st Bank - Mark Tuvell Check No. 74264 Name on the check Telephone 272-6044 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted b Sh cGilvre ` Payment Recd $0.00 $4,542.72 Over/Under Signature NOTICE: Pursuant to Government Code Section 660 0(d)(1), his will s�ry. that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from th on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting - RECORDING REQUESTED BY: .Fidelity National Title Company Escrow No. 411904 -CO THIS order No_ When Recorded Mall Document and Tex Statement To: Mr. Mark Tuvell 50855 Washington St, La Quinta, CA 92253 !�'3 -- SYd DOC a 2004-0010620 09/09/2004 e8:00p Fee:10.00 Page i of 2 Doe T Tex Paid RaoorAad in Official Records County of Riversids Gary L. Oreo pssesser, County Clark B Recorder - �I IIIb)111111 IIIII 11111111111 IIIII Iflll III IIIII ISI IIII ArN: / /4-141-UUti-t1 GRANT DEED SPACE ABOVE THIS UNE FOR RECORDER'S USE The undersigned grantors) declafels) - Documentary transfer tax Is 4214.50 ( X ] computed on full value of property conveyed, or N C ] computed on.full value less value of liens or encumbrances remaining at time of sale, K$ M [ ) Unincorporated Area City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, Wayne W. Southern and Linda F. Southern, Husband and Wife as Joint Tenants hereby GRANTIS) to Mark Tuvell, A Married Man•as We and Separate Property the following described real property In the City of La Quinta County of Riverside, State of California: Lot 18, Block 196 of Santa Carmelite at Vale La Quinta, Unit #19, as per map recorded in Book •19, Page 33 of Maps, in the Office of the County Recorder of said County. DATED: June 24, 2004 STATE OF CALIFORNIA COUNTY OF k -Os la►�t�plc� ON J.,►r\t Tck. ZooYi before me, personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(4 whose name(q) is/at&subscribed to the within instrument and acknowledged to me that he/she/tgay executed the same in4vis/her/their authorized capacity(ies), and that by Ws/her/21teir signatures) on the instrument the personlsi; or the entity upon behalf of which the person(a) acted, executed the instrument, Witness my hand and official seal. Signature JA...Je.,,• FD -213 Mery 7/96) SHARON MON?'OE COMM. # 1345012 No!ory Public - Colifomio ; LIDS ANGELES COUNTY My Cemmisslon (Virus March 6, 2006 ti's•` 'f, MAIL TAX STATEMENTS AS DIRECTED ABOVE GRANT DEED 10 TO 39Vd ONI S1W b000ZLL09L 6T:ZT bOOZ/9T/60 r MEN :.0 ArN: / /4-141-UUti-t1 GRANT DEED SPACE ABOVE THIS UNE FOR RECORDER'S USE The undersigned grantors) declafels) - Documentary transfer tax Is 4214.50 ( X ] computed on full value of property conveyed, or N C ] computed on.full value less value of liens or encumbrances remaining at time of sale, K$ M [ ) Unincorporated Area City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, Wayne W. Southern and Linda F. Southern, Husband and Wife as Joint Tenants hereby GRANTIS) to Mark Tuvell, A Married Man•as We and Separate Property the following described real property In the City of La Quinta County of Riverside, State of California: Lot 18, Block 196 of Santa Carmelite at Vale La Quinta, Unit #19, as per map recorded in Book •19, Page 33 of Maps, in the Office of the County Recorder of said County. DATED: June 24, 2004 STATE OF CALIFORNIA COUNTY OF k -Os la►�t�plc� ON J.,►r\t Tck. ZooYi before me, personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(4 whose name(q) is/at&subscribed to the within instrument and acknowledged to me that he/she/tgay executed the same in4vis/her/their authorized capacity(ies), and that by Ws/her/21teir signatures) on the instrument the personlsi; or the entity upon behalf of which the person(a) acted, executed the instrument, Witness my hand and official seal. Signature JA...Je.,,• FD -213 Mery 7/96) SHARON MON?'OE COMM. # 1345012 No!ory Public - Colifomio ; LIDS ANGELES COUNTY My Cemmisslon (Virus March 6, 2006 ti's•` 'f, MAIL TAX STATEMENTS AS DIRECTED ABOVE GRANT DEED 10 TO 39Vd ONI S1W b000ZLL09L 6T:ZT bOOZ/9T/60 COACH ELLA VALLEY IWER DISTRICT CASH.RECEIPT:;DETAIL CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING Builder Contact / . Telephone �i11r GgirMdolp f ( %(0) ;Z /?- S7Z.3 HER$ Rater I Teleohone 9 Date / / -fZ T41 -- Builder Name Plan Number Sample Group Number CF -4R Pbrtifying Signature ' ' Date Sample House Number Firm: 3—,L' 'tA;-OC14-ZLS HERS Provider: Street Address: �%��b !� (�V4��oY� /YL �>✓ City/State/Zip: u (J1,71a 1 C/Q L72-2-1, Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was:Tested El Approved as part of sample testing, but was not tested 47- As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form com I with the diagnostic tested compliance requirements as checked on this form. Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu f ducts) ALJ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. R MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM /07 If fan flow is calculated as 400cfm/ton x number of tons enter _ r,, calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = 5, A Check Box for Pass or Fail (Pass=6% or less) ❑ Pass Fail THERMOSTATIC EXPANSION VALVE (TXV) or Comrriission approved equivalent P"'Yes ❑ No Thermostatic Expansion Valve (or Commission approved equivalent) is installed and Access is provided for inspection ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1 R and design on plan.1 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, �/i/ verified fan flow matches design from CF -1 R. Measured Fan Flow = Yes for both 1 and 2 is a Pass Pass Fail TITLE 24 REPORT I Title 24 Report for: Sante Fe Montezuma 53-840 Avinda Montezuma La Quinta, CA 92253 Project Designer: Mark Tuvell Report Prepared By: Jason Campanella 50-855 Washington St. #149 La Quinta, CA 92253 (760) 590-9501 CITY OF LA QU NI q BUILDING & SAFETY DEPT. APPROVED FOR CONSTR CTION DATE —If o o -q- gY . Job Number: 0009 Date: 8/30/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0009 User Number. 5961 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 8 13 15 EnergyPro 3.1 By EnergySoft Job Number: 0009 User Number 5961 P J Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Sante Fe Montezuma 8/30/2004 Project Title Date 53-840 Avinda Montezuma La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2, 028 ft2 Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 2,028 ft2 Building Type: Frame (check one or more) Location/Comments © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor ttN1=51RATION Type Orientation Area Const. Fenestration Exterior Component Frame Assembly Location/Comments Type Type U -Value (attic, garage typical etc.) R-19 Roof (R.19.2x8.16) Wood 0.051 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof ttN1=51RATION Type Orientation Area Fenestration Exterior Overhang Side Fins SF) U -Factor SHQC Shading Yes / No Yes / No Right 4.5 0.60 0.69 Bug Screen ❑ X❑ ❑ x❑ Right 33.4 0.64 0.63 Bug Screen ❑ X❑ ❑ Q Rear 72.0 0.71 0.63 Bug Screen ❑ Q ❑ 0 Left 33.4 0.64 0.63 Bug Screen ❑ Q ❑ o Rear 14.0 0.60 0.69 Buq Screen ❑ 0 ❑ Q Rear 33.4 0.64 0.63 Bug Screen ❑ 0 ❑ Q Left 12.0 0.60 0.69 Bug Screen ❑ Q ❑ Q Left 6.0 0.71 0.63 Bug Screen ❑ 0 ❑ Q Front 6.0 0.60 0.45 Bug Screen ❑ FX1 ❑ Q Front 40.0 0.71 0.63 Bug Screen ❑ Q ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initi ti Ti e: 08130/0422:50:34 Run Code: 1093931434 EnemyPro 3.1 By Ener Soft User Number: 5961 Job Number. 0009 Page: 3 of 16 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Sante Fe Montezuma 8/30/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts attic, etc) R -Value Type Comments 81%AFUE Ducts in Attic 42 Seffiack zone 1 81 % AFUE Ducts in Attic 42 Setback Anne 2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Packaged Air Conditioner 12.0 SEER Ducts in Attic 42 Setback zone 1 Packaged Air Conditioner 1 02� SSEER_ Ducts in Attir. 42 Sethark zone 2 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value STATE -1 HP Heat Pump_ Standard 1 15 35A 47 1.90 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Bhdhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS I"�AAA DI 1A �1/'�C l�TA Tr•u�uT .... 8- V 1 r11 1W.1V11V.17 1 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm Address: Mark Tuvell Telephone: Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: EneravPro 3.1 By EnerovSof User Number: 5961 (date) Name: Title/Firm: Address: Telephone: Jason Campanella 50-855 Washington St. #149 La Quinta, CA 92253 Job Number: 0009 (date) 4of16 Certificate of Compliance: Residential - (Addendum) CF -1 R Sante Fe Montezuma 8/30/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS nrnuidur T6n 4=042 —#-........6 a__...-_�.�- e:_• - - - ---• -••----___... •.• -•- ... •...`..... o...... -U uIaynaiauc Rsung yr mese measures on a Torm G145tZ. The HVAC System "zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. _OFa_n7 Field The HVAC System "zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. I Run Initiation Time: 08/30/04 22.50.34 Run -Code: 1093931434 InergyPro 3.1 By Energysaft User Number. 5961 Job Number 0009 Page 5 of 16 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures �'§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not to apply exterior mass walls). E] ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permfinch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemaVextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number. 0009 Page:6 of 16 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 63; ducts insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 3. Joints and seams cf duct systems and their components shall not be sealed with cloth back rubber adhesive dud tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 789E thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot 2. System is installed with at least 36' of pipe between finer and heater for future solar, cover for outdoor pools or spas. a. At least 39' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §1 50(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 Iumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 Iumenstwatt or greater switched at the entrance to the room or one of the aftemative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5961 Job Number: 0009 Page:7 of 16 Computer Method Summary (Part 1 of 3) C -2R Sante Fe Montezuma 8/30/2004 Project Title Date 53-840 Avinda Montezuma La Quinta Project Address Building Permit # Jason Campanella (760) 590-9501 plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 4.15 Facing North Margin Thermostat Facing East Margin Zone Name Facing South Margin Zone Type Type Facing West Margin 2.28 1.87 2.85 1.29 3.29 0.86 2.72 1.42 Space Cooling 43.73 41.37 2.36 °❑� 40.57 3.15 37.47 6.25 41.90 1.83 Domestic Hot Water 12.92 1 10.43 2.49 10.43 2.49 10.43 2.49 10.43 2.49 54.08 6.71 53.86 6.93 1 51.19 9.60 55.05 5.74 Totals 60.79 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 2,028 ft 2 Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 12.6% Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,252 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 2,028 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt Area 70nP 1 Q9Q --a is -0 4.1; 109 9 R91 54_ ronditionPd Setback- conditioned Setback -2 -n/a -2 -n/a lone 2 OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Lneatinn / Cnmmpntc Roof 857 0.051 _ 0 _Q Wall- 111 0 059 270 _gQ_ Door 20 0.387 270 gn Wall 376 0.059 180 90 Wall 136 0.059 90 A ®❑ LJ ❑ ❑ ❑ - ------------ R-19 Rnnf (R 19 2Y8 1 r,) inne 1 R-13 Wan w/1" EPS lone 1 Solid Wood Door zone 1 R-13 Wall w/1" FPS znne 1 R-13 Wall w/1" FPS znne 1 R-13 Wall W/1" EPS Zone 2 R-13 Wall w/1" FPS iene 2 Wall 163 0.059 180 90 Wall 175 0.059 90 90 Wall 432 0.059 _a 90❑ Roos- 99 0.024 _n _ 0 ® ❑ R-13 Wall w/1" FPR inne 2 R-38 Roof (R 38 2r4 24) zone 2 F ❑ 10 ❑ °❑� ❑❑❑ ❑ ❑❑ ❑❑ °❑❑ n Initiation Time; QB/30[04 22:60:34 Run 1093931434 -CQde; 3.1 By EnergySoft User Number. 5961 0009 Page:8 of 16 Computer Method Summary (Part 2 of 3) C -2R Sante Fe Montezuma 8/30/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Window Right poo 4.5 0.600 a 270 90 Mtl Thermal Brk Clear D &wR 1 2 Window Right (West) 33.4 0.640 0.63 270 90 Mb Thermal Brk Clear Default sone zone 1 3 Window Rear (South) 25.0 0.710 0.63 180 90 Mtl Thermal Brk Clear Default zone 1 4 Window Rear (South) 12.0 0.710 0.63 180 90 Mtl Thermal Brk Clear Default zone 1 5 Window Rear (South) 35.0 0.710 0.63 180 90 Mb Thermal Brk Clear Default zone 1 6 Window Left (East) 33.4 0.640 0.63 90 90 Mb Thermal Brk Clear Default zone 1 Z Window Rear (South) 7.0 0.600 0.69 180 90 Mtl Thermal Brk Clear Default 2 8 Window Rear (South) 33.4 0.640 0.63 180 _ 90 Mtl Thermal Brk Clear Default zQne zone 2 5 Window Rear (South) 7.0 0,600 0.69 180 90 Mtl Thermal Brk Clear Default 2 AD Window Left (East) 12.0 0.600 0.69 90 90 Mt1 Thermal Brk Clear Defack _zone sone 2 " Window Left (East) 6.0 0.710 0.63 90 90 Mtl Thermal Brk Clear Default zone 2 12 Window Front (North) 6.0 0.600 0.45 0 90 Mt1 Thermal Brk Clear Default zone 2 -U Window Front (North) 16.0 0.710 0.63 0 90 Mt1 Thermal Brk Clear Default 14 Window Front (North) 8.0 0.710 0.63 0 90 Mt1 Thermal Brk Clear Default zone 2 zone 2 15 Window Front (North) 16.0 0.710 0.63 0 90 Mb Thermal Brk Clear Default zone 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin Exterior Shade Type SHGC Hgt. Wd• Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Buq Screen 0.76 5 Buq Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 3.1 By EnergySoft User Number: 5961 Job Number. 0009 Page:9 of 16 %gumputer memos summary (Part 3 of 3) C -2R Sante Fe Montezuma Pipe Pipe Insul. System Name Length Diameter 8/30/2004 Project Title Minimum Duct Type (air conditioner, Efficiency Date THERMAL MASS FOR HIGH MASS DESIGN (SEER) (attic etc Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val Comments Erame Wall Stucco 111 0_88 21 _047 R-13 Wall w/1" EPS sone 1 / EYterior Mass Frame Wall, Stucco 376 0_88 21 0`47 R-13 Wall w/1" EPS _2 2 _ zone 1 / Exterior Mass Frame Wall, Stucco 136 0_88 21 0.47 RA Wall w/1" E S zone 1./ Exterior Mass Frame Wall, Stucco 163 0_88 21 0.47 R-13 Wall w/1" EPS —2 2 zone 2 / Exterior Mass Frame Wall, Stucco 175 0.88 21 0.47 R-13 Wall w/1" EPS —2 -nne 2 / Exterior Macs PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 133 0.76 0.0 — 0 zone 1 Slab Perimeter 148 0.76 0.0 0 zone 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic etc) R -Value Type Comments Central Furnace 81%AFUE Ducts in Attic 4.2 Setback zone 1 Central Furnace 81%AFUE Ducts in Attic 4.2 Setback zone 2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic etc Duct Thermostat R -Value TvDe Location / Comments Packaged Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback zone 1 Packaged Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback zone 2 WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) (gal) Efficiency Loss (%) Ext. STATE S"-52-1 HP Heat Pump Standard 1 15,359 47 1.90 Na n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Part 3 of 3) C -2R Sante Fe Montezuma 8/30/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val Comments Frame Wall Stucco 432 0_88 —210_47 R-13 Wall w/1" FPS -2 zone 2 / Fxferior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic etc) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) (gal) Efficiency Loss M) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Sante Fe Montezuma 8/30/2004 Project Title Date bpecial Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies -•• -•- ��..ry �.+..� ... ..... .ar--J-... HVII a11Y UV UIIICIIUIUUU buumuxeu. Plan I Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF•6R.Plr an I Field I The HVAC System "zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number 0009 Page: 12 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sante Fe Montezuma 8/30/2004 SYSTEM NAME FLOOR AREA zone 1 929 Number of Systems 1 Heating System Output per System 64,000 Total Output (8tuh) 64,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 14183 0 15441 YORK D1 HE048A25/46 33,055 0 64,000 Total Adjusted System Output 33,055 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2pm LLL�Jan 12 am 26.0 of 68.9 of 110.0 of %� d Outside Air 0 cfm 68.9 of 11.0 / 77.6 of Outside Air 0 cfm 75.0/49.7 of Heating Coil 0 Supply Fan 600 cfm 110.0OF --�! Supply Air Ducts 108.9 of ROOMS 70.0 of h Retum Air Ducts 4 75.0/49.70f M 23.2/21.50f Cooling Coil of 0 Supply Fan 600 cfm 23.2 / 21.5 of Supply Air Ducts 24.3 / 22.2 of 10.8% R.H. ROOMS 74.0 / 49.3 of h Retum Air Ducts `i EnergyPro 3.1 By EnergySoft User Number 5961 Job Number: 0009 Page: 13 of 16 LH -VAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sante Fe Montezuma 8/30/2004 SYSTEM NAME FLOOR AREA zone 2 1,099 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 58.2 Cooling System - Output per System 46,500 Total Output (Btuh) 46,500 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 42.3 Total Output (sgftffon) 283.6 Air System CFM per System 600 Airflow (cfm) 600 Airflow (cfm/sgft) 0.55 Airflow (cfm/Ton) 154.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of Outside �"� 0 cfm 68.4 of 11.0 / 77.6 of Outside 1 0 cfm 79.3/53.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 310 17,155 2,582 506 20,672 0 858 1,034 0 0 0 0 0 0 0 0 0 858 1,034 -,8,8710F 2,5821 22 740 YORK 131HE048A25/46 34,879 0 64,000 Total Adjusted System Output34 879 0 s4,0oo (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ream Temperatures at Time of Heatina Peakl 68.4 of . 110.0 of Heating Coil C Supply Fan 600 cfm 110.0 OF 311h.Supply Air Ducts 108.4 of ROOMS 70.0 of h Retum Air Ducts `i 79.3/53.6OF M 24.7/23.1OF Cooling Coil y Supply Fan 600 cfm 24.7 / 23.1 of -� Supply Air Ducts 26.1 / 24.0 of 14.9% R.H. ROOMS 78.0/53.1OF h Retum Air Ducts `i EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number: 0009 Paw: 14 of 16 ROOM LOAD SUMMARY PROJECT NAME DATE Sante Fe Montezuma 8/30/2004 SYSTEM NAME FLOOR AREA zone 1 929 EnergyPro 3.1 By EnergySoft User Number. 5961 Job Number.• 0009 Page 15 of 16 ROOM LOAD SUMMARY PROJECT NAME Sante Fe Montezuma DATE 8/30/2004 SYSTEM NAME zone 2 FLOOR AREA 1 099 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM ISENSIBLE LATENT CFM SENSIBLE zone 2 zone 2 1 310 17,155 2,582 310 17155 2,582 506 20,672 PAGE TOTAL 310 17,155 TOTAL 310 17,1552,582 2,582 506 20,672 50620,672 EnergyPro 3.1 By EnergySoft User Number: 5961 Job Number 0009 Page 16 of 16