BMCH2015-018078-495 CALLE TAMPICO VOICE (760) 777-7125 C� 0 V -`
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
r),+.:. 6/2015
Application Number: BMCH2O15-0180 0
Property Address: 54280 AVENIDA MONTEZUMA PA
APN: 774231002
Application Description: KOWALEWSKI RESIDENCE HVAC CHANGE OUT 3"
6 2015
Property Zoning:
Application Valuation: $11,000.00
CITY OF LA QUINTA
Applicant: Co ffY DEVELOPMENT DEPARTMENT
ESSER SERVICES INC DBA ESSER A ESSER SERVICES INC DBA ESSER A
P O BOX 1636 P 0 BOX 1636
CATHEDRAL CITY, CA 92235 CATHEDRAL CITY, CA 92235
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 489046
Date: A21 J6 Contractor: Jsa.ZT —
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
( ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
(760)324-0550
LIC. No.: 489046
• WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Za=.. I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier:_ Policy Number: _
- I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions. ''AA
Date: 5 2(v t5 Applicant: YL
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictionsset forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above•
mentioned property for inspection purposes.
Date: 15 Signature (Applicant or Agent): ScZE—
::DESCRIPTION
FINANCIAL
ACCOUNT :QTY
AMOUNT
PAID PAID DATE
BSAS SB1473 FEE
101-0000-20306 0
$1.00
$0.00
PAID BY
METHOD RECEIPT #
CHECK # CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY .
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$72.52
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$36.26
$0.00
PAID -BY
METHOD
RECEIPT #
CHECK.#
CLTD BY
Total Paid forCHANGEOUT: $108.78 $0.00
DESCRIPTION
ACCOUNT
CITY.
AMOUNT.
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY.
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:i 00
Description: KOWALEWSKI RESIDENCE HVAC CHANGE OUT
Type: MECHANICAL Subtype:
Status: APPROVED
Applied: 5/26/2015 MFA
Approved: 5/26/2015 MFA
Parcel No: 774231002 Site Address: 54280 AVENIDA MONTEZUMA LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 260
Lot: 15
Issued:
UNIT 24
Lot Sq Ft: 0 Building Sq Ft: 0
Zoning:
Finaled:
Valuation: $11,000.00 Occupancy Type:
Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0
No. Unites: 0
FAX
Details: 4 TON HEAT PUMP AND AIR HANDLER [2008 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL
INSPECTION. 2013 CALIFORNIA BUILDING CODES.
ESSER SERVICES INC DBA ESSER A
P 0 BOX 1636
CHRONOLOGY
CONTACTS
NAME'TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
ESSER SERVICES INC DBA ESSER A
P 0 BOX 1636
CATHEDRAL
CITY
CA
92235
CONTRACTOR
ESSER SERVICES INC DBA ESSER A
P O BOX 1636
CATHEDRAL
CITY
CA
92235
OWNER
PAUL KOWALEWSKI
92253
FINANCIAL INFORMATION
Printed: Tuesday, May 26, 2015 12:43:38 PM 1 of 2 C
SYSTEMS
INSPECTIONS
3EQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
MECHANICAL FINAL" BLD
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
_
CHECK #
METHOD
PAID BY
BY
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
HVAC CHANGEOUT -
101-0000-42402
0
$72.52
$0.00
SPLIT -SYSTEM
HVAC CHANGEOUT -
101-0000-42600
0
$36.26
$0.00
SPLIT -SYSTEM PC
Total Paid forCHANGEOUT: $108.78 $0.00
PERMIT ISSUANCE
F101-0000-42404
0
$91.85
$0.00
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:i 00
INSPECTIONS
3EQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
MECHANICAL FINAL" BLD
I. PARENT PROJECTS
Printed: Tuesday, May 26, 2015 12:43:38 PM 2 of 2
SYS7EiNS
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC)
Project Name:
PAUL KOWALEWSKI I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3 )
2015-05-22
A. General Information
MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be
documented, use one CF1R-ALT-02 document for each dwelling unit.
01
Project Name
PAUL KOWALEWSKI
02
Date Prepared
2015-05722
03
Project Location
54280 AVENIDA MONTEZUMA
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
PAUL KOWALEWSKI
07
Zip Code
92253
08
Dwelling Unit Conditioned
1728
�w •*seer^
,� ,R ..
.� .w
Floor Area (ft2)
SC System
CFA served
system a
r f igea t t
installing a SC
Number of space conditioning
I� talli g
09
Climate Zone
15
10
(SC) systems in this dwelling
1
containing
system
more than 40
entirely new
unit.
B. Space Conditioning (SC) System Information AOMW
owl
Ol
02
03
JIq05J0607
08
t 09
10
..Ik04
-'
Is the SC
ham.
Installing a
se+ 'w .:
�w •*seer^
,� ,R ..
.� .w
SC System
SC System
CFA served
system a
r f igea t t
installing a SC
Installing
I� talli g
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
1728
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 215-A0137035A-000000000-0000
Registration Date/Time: 2015-05-22 12:37:26
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-05-22 12:37:15
Schema Version: 0.555SDD
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 )
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name"
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central split
All new
Central split
All new
This field or
This field or
System 1
HP
heating
AFUE
0.8
HP
cooling
SEER
13
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans
-Duct insulation requirement for new plenums: R6.
CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced.
-Leakage rate compliance: 5 15%, or 5 10% leakage to outside, or seal all accessible leaks.
CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow >_ 300 CFM/ton required when MCH -25 is required.
Exceptions:
-Duct systems registered with HERS provider as previously sealed.are exempt from M H 20 Duct Leakage_T_esti g i qui eme tis
-Heating-only systems and Air Handler/Furnace changes do not require verification of Air FltWiVCy 23,!or Refrigerant Charge MECH-257
"
p.. C 5 -' 2 r n �:
Existing duct systems constructed, insulated or sealed with asbestos are exempt, f�rom MCH -'20 Duct leakage Testing requirements.
k
E. Entirely New or Complete Replacement Duct System, with or withoutifqurpment Changeouf(Sections 150.2(b)1Diia'andf150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 215-A0137035A-000000000-0000 Registration Date/Time: 2015-05-22 12:37:26 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-05-22 12:37:15
Schema Version: 0.5555DD
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3 )
Documentation Author's Declaration Statement
1'. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �/
�tn
Jacoby, Ian
acob�
Company:
Signature Date:
Stratz Permit Service
2015-05-22 12:37:11
Address:
CEA/ HERS Certification Identification (if applicable):
5858 Dovetail Drive
City/State/Zip:
Phone:
Agoura Hills CA 91301
1818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Reg l5tionss. 1 J .r l "^
4. The building design features or system design features identified on this Certificate of Compliance are,consistent witty the informafion.provided on other applicable'compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approvaltwith this building permit application. }
Adt '." '.
.-k, �d f=. IT."? j' fn 54 {c
5. I will ensure that a registered copy of this Certificate. of, Compliance shall,_be made;ayailable withahe building, permits) ssued for the building, and made available toahe;enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance_is,requiired to be„included with the he builder provides to the building owner at occupancy.
�documentation
Responsible Designer Name: -.
Responsible Designer Signature: V t ' �".
Esser, MichaelGC,IIRe°�/�y1PJTi
Company:
Date Signed:
ESSER SERVICES INC
2015-05-22 12:37:26
Address:
License:
P O BOX 1636
489046
City/State/Zip:
Phone:
CATHEDRAL CITY CA 92235
(760) 324-0550
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 215-A013703SA-000000000-0000 Registration Date/Time: 2015-05-22 12:37:26 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-05-22 12:37:15
Schema Version: 0.555SDD
Bin #
City of La Quinta
Building 8Z' Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012.
Building Permit Application and Tracking Sheet.
Permit #
Project Address: Z$O Ave.Y-A,dr— 2v
Owner's Name: �r~v1 K ow�lewsk
A. P. Number:
Address: .S LIZBp .,4vCn�c�C, �or�c2�am
Legal Description:
City, ST, Zip: L Qv� �� ca CA qZ?
Contractor:
S S
Telephone: 3 z 3 �- I I P to
Address: �O 3Dx b3 (o
Project Description:
City, ST, Zip: C�,, Ir C_C, CA Ci Z23s
Re-PIaGG y +e►-, Nva k Aic-
Telephone: i 4 - O
-76 o - 3 0,E;&6
r i
State Lie. # : 4 $ QOL4 U
City Lie. #:
Arch., Engr., Designer:
Address:
City., ST, Zip:
h
Telephone:
one:
XXX
Construction n T
o e: Occupancy:
Type: P Y:
State Lie. c #:
Project type (circle one):: New. Add'n Alter Repair r Demo
Name of Contact Person:
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project: I,r Ot 0. c* -:3
APPLICANT: DO NOT WRITE BELOW THIS LINE
k
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'^' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr .
Date of permit issue
School Fees
Total Permit Fees