Loading...
11-1301 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00001301 Property Address: 77345 AVENIDA MONTEZUMA APN: 773-121-001- - Application description: ADDITION - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 13095 Titit 4 XP Q" Applicant: Architect or Engineer: ---------------- ENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under pe4jury I am licensed under provisions o hapter 9 (commencing with Section 7000) of Divisioand Professionals Code, and my, icense is ' full force and effect. License Class: BLicense No.: 6190 Date: �.- /D--1 � OWNER-BUILDER DEC TION I hereby affirm under pet I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this peimit is issued (Sec. 3097, Civ. C.I. Lender's Name: _ Lender's Address: LQPERMIT Owner: RW REAL ESTATE, INC. 52700 AVENIDA ALVARADO LA QUINTA, CA 92253 Contractor: HUITRON CONSTRUCTION 50427 RIGO COURT COACHELLA, CA 92236 (760)398-3227 Lic. No.: 926190 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/10/12 �Ua 2012'IJ Gi'k'Yr r;r LA QUitITA ----------------------------------------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0013718-2010 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, ' the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permi 2. Any permit issued as a result of this application bec mes null and void if work is not com ced within 180 days from date of issuance of su pe it, or cessation of work for 180 day ill subject permit to cancellation. I certify that I have read this application and state that th b e information correct. I agree t mply w' all city and county ordinances and state laws relating to buil n co struction, d hereby gree r resent es of this county t�o�eeenn.-ttee�errr upon the above-mentioned prope r i pection poses. Date: &!i I _ I ture (Applicant or Age Application Number . . . . . 11-00001301 ------ Structure Information 97SF ADDITION WITH REMODEL [ENGINEERED] ----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE 97.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 153.00 Issue Date Expiration Date 8/08/12 Plan Check Fee 99.45 Valuation 13095 Qty. Unit Charge Per Extension BASE FEE 45.00 12.00 9.0000 THOU BLDG 2,001-25,000 108.00 ------=--------------------------------------------------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 35.20 Plan Check Fee . Issue Date . . . . Valuation . . . . Expiration Date . . 8/08/12 8.80 0 Qty Unit Charge Per Extension BASE FEE 15.00 97.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3.40 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 4.00 ---------------------------------------------------------------------------- .4500 EA ELEC DEVICE/FIXTURE >20 1.80 Permit MECHANICAL Additional desc . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date . . . Valuation . . . . 0 Expiration Date . .* 8/08/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 42.00 Plan Check Fee 10.50 Issue Date . . . . Valuation . . . . 0 LQPERMIT Application Number . . . . . 11-00001301 Permit . . . . . PLUMBING Expiration Date 8/08/12 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 6.0000 EA PLB FIXTURE 24.00 1.00 3.0000 EA PLB WATER INST/ALT/REP ---- 3.00 -------------- ---------------------------------------------------------- Special Notes and Comments 97SF DINING ROOM ADDITION WITH REMODEL THROUGHOUT DWELLING/VB/RES-3/CLASS A -FR (ENGINEERED] THIS PERMIT DOES NOT INCLUDE ALTERATION TO THE EXISTING HVAC OR WATER HEATER. 2010 CALIFORNIA BUILDING CODES. February.10, 2012 10:42:42 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 9.95 STRONG MOTION (SMI) - RES 1.31 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 256.20 .00 .00 256.20" Plan Check Total 125.25 .00 .00 125.25 Other Fee Total 12.26 .00 .00 12.26 Grand Total 393.71 .00 .00 393.71 LQPERMIT ei►t c City Of La. Ouin'ta Building.8i Safety Division . P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 1 Project Address: _ O vi GU vvAo^ Owner's Name: A. P. Number: Address: J Legal Description: City, ST, Zip: Contractor. one i ;w.......... Address: d C T o Project Description: t Ian 97 City, ST, Zip: y CA q ZZZl . rah t - C a�z e Telephone: p LA State Lic. # : `Z 6 I CityLic. #: Arch., Engr., Designer. 'u Address: o L City, ST, Zip: Telephone:>.. State Lic. t<.r ' Construction Type: Occu an Pro1ect type (circle one)' New Alt Repair Demo Sq. Ft.: # Stories: #Units: Name of Contact Person: v n Telephone # of Contact Person: 04-57 9 c( E,O JvEstimalzd Value of Project: p 9 5 .0 0 APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd Rec'd TRACMNG PERMIT FEES Plan Sets Plan Check submitted 0,16 Item Amount Structural Calcs. Reviewed, ready for corrections sal Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. ?j Plans picked up Construction Flood plain plan Plans resubmitted echanical Grading plan 2"! Review, ready fore'recti issueI 'f p Z Electrical Subcontactor List Called Contact Person Plumbing Grant Deed I Plans picked up tr j S.M.1. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, ready for correction issue eveloper Impact Fee Planning Approval Called Contact Person WV A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees `l q I J+ V - 10/C 1- l�-r.�. �Iws x�c- ilia lua_ -i`ia`ua_ - Ns Yi4.1t,gtJ 11 al tbl a - (I-;AV4 z0 Kms. w�� CERTIFICATE OF COMPLIANCE 4�J�tFsIo Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES O Cn RANCHO MIRAGE Date 4/17/12 La Quinta, CA 92253 N INDIAN WELLS LM No. 31254 (760) 771-8515 d.?> P QUESERT INTA Y QINDIO 1p Owner RW Real Estate APN # 773-121-001 Address Jurisdiction La Quinta City Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 77345 Avenida Montezuma 97 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Dining Room Addition At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detachedaccessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 97 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Gustavo Huitron Check No. Name on the check Telephone 760-457-9960 Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected lexemp ed by n CGIIVrey Payment Recd $0.00 .� . y , ©vedU,nderc Signature NOTICE: Pursuant to Government Code Section 66020(d)( is will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting V- I I BUILDING ENERGY ANALYSIS REPORT PROJECT: RW Real Estate, Inc./Joseph Arsanto 52700 Avenida Alvarado La Quinta, Ca 92236 Project Designer: EDS COACHELLA, CA 92236 760-296-6130 Report Prepared by: Edgar Torres 1310 2nd St. Coachella, Ca 92236 760-296-6130 Job Number: 15-11 Date: 1/26/2012 0 11.10401 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE Z1� ?aid- sy�Q__ �McEIVED JAN 272012 BY: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 5.0 by EnergySoft Job Number: ID: 15-11 User Number: 6688 2 3 8 11 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name RW Real Estate, Inc./Joseph Arsanto Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1/26/2012 Project Address 52700 Avenida Alvarado La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,393 Addition 98 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-13 159 New Roof Wood Framed Attic R-38 103 New Slab Unheated Slab -on -Grade None 98 Perim = 42' New Wall Wood Framed R-13 884 Existing Door Opaque Door None 20 Existing Roof Wood Framed Attic R-38 1,295 Existing Slab Unheated Slab -on -Grade None 1,295 Perim = 145' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (S) 40.0 0.300 0.30 none none Bug Screen New Left (E) 25.0 0.340 0.28 none none Bug Screen New Front (N) 72.0 1.190 0.83 none none Bug Screen Existing Rear (S) 28.0 1.190 0.83 none none Bug Screen Existing Right (W) 40.0 0.300 0.30 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 93% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.0 by Energ Soft User Number 6688 RunCode: 2012-01-26T09:06:5 ID: 15-11 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name RW Real Estate, Inc./Joseph Arsanto Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1/26/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Water Heater Standar 50 Gal has an EF less than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.0 by EnergySoft User Number- 6688 RunCode: 2012-01-26T09:06:5 /D: 15-11 Page 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date RW Real Estate, Inc./Joseph Arsanto ❑ Multi Family 10 Existing+ Addition/Alteration 1112612012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/V- r Space Heating 6.82 5.52 1.30 Space Cooling 168.05 137.61 30.44 Fans 36.43 30.11 6.32 Domestic Hot Water 24.02 24.02 0.00 Pumps 0.00 0.00 0.00 Totals 235.32 197.26 38.06 Percent Better Than Standard: 16.2 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 368 72 Fuel Available at Site: Natural Gas (E) 266 25 Raised Floor Area: 0 (S) 368 68 Slab on Grade Area: 1,393 (Vl9 266 40 Average Ceiling Height: 8.0 Roof 1,398 0 Fenestration Average U -Factor: 0.74 TOTAL: 205 Average SHGC: 0.56 Fenestration/CFA Ratio: 14.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company / 1/26/2012 Address 1310 2nd St. Name Edgar Tones City/ tate/ZiCoachella, Ca 92236 Phone 760-296-6130 Sin Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company EDS Address Name EDGAR TORRES City/State/Zip COACHELLA, CA 92236 Phone 760-296-6130 Signed License # Date EnerqvPro 5.0 by Ener Soft User Number- 6688 RunCode: 2012-01-26T09:06:5 ID: 15-11 Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name RW Real Estate, Inc./Joseph Arsanto Building Type m Single Family ❑ Multi Family ❑ Addition Alone m Existing+ Addition/Alteration Date 1112612012 OPAQUE SURFACE DETAILS LI -Factor SHGC Azm Status Glazing Type Location/Comments Surface Type Area Ll- Insulation Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wall 56 0.102 R-13 0 90 New 4.3.1-A3 Proposed 90 New Wall 16 0.102 R-13 180 90 New 4.3.1-A3 Proposed 0 Existing Wall 87 0.102 R-13 90 90 New 4.3.1-A3 Proposed 0 Existing Roof 1031 0.025 R-38 0 341 New 4.2.1-A21 Proposed 0 Existing Slab 98 0.730 None 0 180 New 4.4.7-A1 Proposed 90 Removed Wall 220 0.102 R-13 0 90 Existing 4.3.1-A3 Proposed 180 Existing Door 20 0.500 None 0 90 Existing 4.5.1-A4 Proposed 180 Existing Wall 154 0.102 R-13 90 90 Existing 4.3.1-A3 Proposed 180 Existing Wall 72 0.102 R-13 90 90 Removec 4.3.1-A3 Proposed 0.83 Default Wall 284 0.102 R-13 180 90 Existing 4.3.1-A3 Proposed 0.30 NFRC Wall 226 0.102 R-13 270 90 Existing 4.3.1-A3 Proposed Roof 1,295 0.025 R-38 0 341 Existing 4.2.1-A21 Proposed Slab 1,295 0.730 1 None 0 180 Existinq 4.4.7-A1 Pr000sed FENESTRATION SURFACE DETAILS (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 40.0 0. 3001 NFRC 0.30 NFRC 180 New JeldWen Proposed 2 Window 25.0 0. 3401 NFRC 0.28 NFRC 90 New Loewen Dbl/Wd Mt/clad Low -E Proposed 3 Window 40.0 1.190 1 Default 0.83 Default 0 Existing Single Metal Clear Proposed 4 Window 16.0 1.190 Default 0.83 Default 0 Existing Single Metal Clear Proposed 5 Window 16.0 1.190 Default 0.83 Default 0 Existing Single Metal Clear Proposed 6 Window 40.0 0.300 NFRC 0.30 NFRC 90 Removed JeldWen Proposed 7 Window 12.0 1.190 Default 0.83 Default 180 Existing Single Metal Clear Proposed 8 Window 7.0 1.190 Default 0.83 Default 180 Existing Single Metal Clear Proposed 9 Window 9.0 1.190 Default 0.83 Default 180 Existing Single Metal Clear Proposed 10 Window 16.0 1.190 Default 0.83 Default 270 Removed Single Metal Clear I Proposed 11 Window 40.0 0.300 NFRC 0.30 NFRC 270 New JeldWen I Pr000sed I EnergyPro 5.0 by EnergySoft User Number. 6688 RunCode: 2012-01-26T09.06.5 ID: 15-11 Page 6 of 11 (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window Overhan Left Fin Richt Fin SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 IBug Screen 1 0.76 I EnergyPro 5.0 by EnergySoft User Number. 6688 RunCode: 2012-01-26T09.06.5 ID: 15-11 Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name RW Real Estate, Inc./Joseph Arsanto Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1/26/2012 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existinq Altered Removed Volume Year Built HVAC System Proposed 98 784 Existing 1,295 10,360 2000 Totals 98 0 1,295 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Type Min. Eff. Thermostat Type Status —Cooling HVAC System 1 Central Fumace 93 % AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Ducts Duct Location R -Value Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standar 50 Gal 1 Small Gas Kitchen Pipe Ins 40,000 50 0.51 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E w a Hot Water Piping Length ft)c 0 a — System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnergyPro 5.0 by EnerqySoft User Number: 6688 RunCode: 2012-01-26T09:06:5 ID: 15-11 Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name RW Real Estate, Inc./Joseph Arsanto Date 1/26/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 1 50 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, a ui ment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.0 by EnergySoft User Number: 6688 RunCode: 2012-01-26709:06:58 ID: 15-11 Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date RW Real Estate, Inc./Joseph Arsanto 1/26/2012 §150(m)l : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover: §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.0 by EnergySoft User Number: 6688 RunCode: 2012-01-26T09:06:58 ID: 15-11 Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date RW Real Estate, Inc./Joseph Arsanto 1/26/2012 §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five wafts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.0 by EnergySoft User Number: 6688 RunCode: 2012-01-26709:06:58 ID: 15-11 Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name RW Real Estate, Inc./Joseph Arsanto Date 1/26/2012 System Name HVAC System Floor Area 1,393 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 952 21,517 Return Vented Lighting 0 Return Air Ducts 2,060 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,060 TOTAL SYSTEM LOAD 25,637 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 94,000 2,722 512 23,696 Total Output (Btuh) 94,000 Output Btuh/s ft 67.5 1,758 Cooling System 0 Output perSystem 23,700 0 0 0 Total Output Btuh) 23,700 2,722 0 Total Output (Tons) 2.0 1,758 Total Output (Btuh/s ft) 17.0 Total Output s ft/Ton 705.3 27,212 Air System CFM perSystem 1,100 HVAC EQUIPMENT SELECTION Airflow cfm 1,100 Carrier 58MTB100-16 CNP 38HD 2.5T 20,593 0 94,000 Airflow cfm/s ft 0.79 Airflow cfm/Ton) 557.0 Outside Air %) 0.0% Total Adjusted System Output 20,593 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM 94,000 Outside Air cfm/s ft) 0.00 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,100 cfm 68 OF 68 OF 115 OF Ff I I Heating Coil 113 OF ROOM fE 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/64°F 80!64°F 55!54°F Outside Air 0 clm AL Supply Fan Cooling Coil 57 / 54 OF 1,100 cfm-------- #�--- ��+ 43.6% ROOM 80/64°F 78/63°F EnergyPro5.0 by EnergySoft User Number- 6688 RunCode: 2012-01-28709:06:58 ID: 15-11 Page 11 of 11