Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
0011-162 (MISC)
"LICENSED CONTRACTOR DECLARATION I hereby affirm under penally of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # / Lic.,Class Exp. Date L/Date �1- 16'0 Signature of Contractor-_�1_1 '""`e'' �� ` '"y,` A� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor.'s License Law for the following reason: ( ) I, as owner of the, property, or my employees with, wages as their sole compensation, will do the work, and the structure -is not intended or offered for sale (Sec. 7044, Business & Professionals Code). . ( ) I, as owner of the property, am exclusively. contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals' Code). O I am exempt under Section B&P.C. for this reason ' Date, Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm, under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent to self-insure.for workers' compensation; as provided.for by Section 3700 of the•Labor•Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation, insurance, as required by Section 3700 of the Labor Code, `for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy 6o:' are: Carrier Policy'No. EXEMPT (This section'need not be completed if the permit valuation is for $100.00 or less). (.Kl certify that in the performance of the work for which this permit is issued, I .shall not employ any person in any manner so as to become subject to`the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 37.00 of the Labor Code, I shall forthwith comply with those provisions: Date: Applicant -- Warning: Failure to secure Workers' Compensation coverage is unlawful and Shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of. compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director.of Building and Safety for a permit subject'to the ,conditions and -restrictions set forth on his application. 1. Each person upon whose:behalf this application is made & each person at whose request and for whose benefit work is performed under 'or pursuant to any permit issued as a result of this applicaton agrees to, &.shall, indemnify & hold harmless the City of La Quinta,, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced' within 180 days from date of issuance of such permit, or cessation'of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree too Comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes: ,Signature (Owner/Agent)ri�`"' j,'�. x: " `- Date t l - a au d3 LI) BUILDING PERMIT PERMIT# L l� DATE VALUATION LOT ��� �.'^A.r�R� TRACT � I1o`16t 2M '.�li�z��c�.Go .. JOB SITE ADDRESS. APN 77-41 AVENI DAMOx+f"M, 1A9.A OWNER CONTRACTOR/DESIGNER/ENGINEER ,ANNY&KG P101h ly Sb1OR OrNSTRU .VIOy V_ r titer mm -T. RULLERTON CA BERMUDA DMES CA, 9=01 USE OF PERMIT TtMO'ti'• TI0MS 9O =WS'PINa BCffL;i:)f;Nd u KM%tEL SPACRI .ANI•D OFMM11'Ft SPACE VALUATION La d: rQa'.I.S'LI11�tS.4'IID4,�8/! R:.'S!M7}'.4 OF C0S'i'I,4.�' R.'RJ(1311W.+Z 8.'r."iq'lM7'f+P�VAa •ypyy77�� }}��,••��,�$��rry�•, y� LL �i, ��YY��yR�����^',�g.. Y IDnAh=Er'3a .i, .i3 EE A7 U1.y.MS°'l fA PI f`'lWKl�'l1;ls 101-000.439.318 $122.85 i,�dxIM"WAL I'E 101-000-421-000 S45,00 izt,,l+; ITRI,C.19d.?FY, -Y)00-4204VO 1»« Pwww.lu P'f p ) L1 d W01?C�w6 i 00CI MOO S'd'kt)N'..f' MOTIONFEE EE COA41.: 1,, 00-1000-24 # —M .�t7��-Fs�'�:�:. �.SI�1�'•o'�`A.�t�'L$l�].'l,�t� � �'�1.�`�'�• ��'.. �3'� �.t:'.� UM IMM, 'M�lyR.":P lJ:ir .kY,U NO9f9 SO?,&% RECEIPT DATE 3 ]� BVii> Ir�J V T /G+ DATEFINALED INSPE TOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Hacks Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G. F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: TITLE 24 REPORT Title 24 Report for: Village Park Kennel and Grooming La Quinta, CA 92253 Project Designer: Brian de Coster, Tdc Associates 69136 San Helena Cathedral City, CA 92234 (760) 770-6924 Report .Prepared By: Carole Christensen Carole Christensen, Analyst 47596 Lake Canyon Drive Aguanga, CA 92536 (909) 763-0522 CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED bdc010000 FOR CONSTRUCTION DATE J BY Date: fftcc 11/8/2000 RiM, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: bdc010000 User Number: 2248 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV -3 Proposed Construction Assembly 12 Form ENV -MM Envelope Mandatory Measures 14 Form LTG -MM Lighting Mandatory Measures 15 Form MECH-MM Mechanical Mandatory Measures 16 ,.a EnergyPro 2.1 By EnergySoft Job Number: bdc010000 User Number: 2248 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME Village Park Kennel and Grooming This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 DATE 11/8/2000 PROJECT ADDRESS La Quinta SIGNATURE BUILDING CONDITIONED FLOOR AREA 607 sq.Ft. CLIMATE ZONE 15 PRINCIPAL DESIGNER - ENVELOPE Brian de Coster, Tdc Associates TELEPHONE (760) 770-6924 Building Permit # DOCUMENTATION AUTHOR Carole Christensen, Analyst TELEPHONE (909) 763-0522 Checked by/Date Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DATE OF PLANS SIGNATURE BUILDING CONDITIONED FLOOR AREA 607 sq.Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ® ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE Carole Christensen� Z-11— The Principal Designers hereby certify that the proposed building design represented in•i- construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ F� F-] 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. n F-1 2. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. F ❑ ❑ 3. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section of the Code to sign this document as the person responsible for its preparation; and for the following reason: ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE Brian de Coster Tdc Associates LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LTG -1 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE C. NO. DATE Brian de Coster Tdc Associates MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE Brian de Coster Tdc Associates I EnerovPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Paae:3 of 17 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PER ' Village Park Kennel and Groomin DATE 11/8/2000 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r ENERGY COMPONENT Standard Design • Proposed Design Compliance Margin standard €^.:�'er°pasea Space Heating Space Cooling Indoor Fans Heat Rejection Pumps Domestic Hot Water Lighting Receptacle Process TOTALS: 36.59 38.57 -1.98 w.� 179.99 182.46 -2.47 6pO0efovMnp-- 23.73 27.20 -346 x' } 'nmmtPan9:;fi it ter; :. I 20 40 60; 80 .100 120 140. 160 180 " kBtwsgft yr 0.00 0.00 000 0.00 0.00 0.00 19.28 12.20 7.09_ 40.05 39.06 0.99 16.81 16.81 0.00 gg 0 316.47 316.30 0.16 BUILDING COMPLIES ' GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones west 270 deg Conditioned Floor Area 607 sqft. Unconditioned Floor Area 0 sqft. Conditioned Footprint Area 607 sqft. 1 1 2 Orientation Front Elevation (west) Left Elevation (North) Rear Elevation (East) Right Elevation (South) Total Roof Gross Area sqft. sqft. sqft. sqft . sqft. sgft. Glazing Area Glazing sqft. sqft. sqft. 1sgft. sqft. sqft. Ratio 621 22 3.6% '85 0 0.0% 621 0 0.06/0 88 o 0.0°/a 1,415 22 607 [E: -o E0.0% Standard Proposed• Lighting Power Density 1.360 w/sgft. 1.327 w/sgft. Prescriptive Env. Heat Loss 459 547 Prescriptive Env. Heat Gain 31,334 26,382 Remarks: Run Initiation Time: �EnergyP,o 11/08/00 12:53:27 Run Code: 973716807 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:4 of 17 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3' PERF -1 PROJECT NAME Village Park Kennel and Grooming DATE 11/8/2000 ZONE INFORMATION " System Name Zone Name Occupancy Type Floor Inst. Area LPD (sqft.) (W/sf)1 Ctrl. Tailored Credits LPD'- Vent. (W/sf)2 ' (W/sf) 3 (cfm/sf) Proc. Loads (W/sf) Kennel & Grooming Grooming Room Retail/Wholesale Sales 219 1.184 Kennel Industrial Work, Low Bay 388 1.40 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST i ne iocai enforcement agency snouia pay special attention to the items specitiea in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special •ustification and documentation submitted. Plan Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp 0- eM EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:5 of 17 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME Village Park Kennel and Grooming DATE 11/8/2000 OPAQUE SURFACES # Surface Framing Type Type Act. Area U -Val. Azm. Solar Gains Tilt y/N Form 3 Reference Location / Comments 1 Demising Wood 88 0.059 0 90 1 IXIR-13 Wall w/1" EPS Grooming Room faces Kennel 2 Roof Wood 219 0.027 0 0 IX I I Roof R38 drop ceiling Grooming Room 3 lWall None 88 0.671 180 90 IX 1 18" Concrete Wall Grooming Room 4 Wall None 165 0.671 90 90 1& 18" Concrete Wall Groorninq Room 5 Wall Wood 122 0.059 270 90 x I R-21 Wall W.21.2x6.16 Grooming Room 6 Door None 20 0.098 270 90 X I Insulated Metal Door Grooming Room 7 Dernising Wood 88 0.059 0 90 X R-13 Wall w/1" EPS Kennel faces Grooming Room 8 Roof Wood 388 0.028 0 0 X Roof R38 no drop ceiling Kennel 9 Wall None 456 0.671 90 90 X 18" Concrete Wall Kennel 10 lWall[Wood 85 0.059 0 90 X R-21 Wall W.21.2x6.16 Kennel 11 Wall Wood 376 0.059 270 90 X R-21 Wall W.21.2x6.16 Kennel 12 Door None 20 0.098 270 90 X Insulated Metal Door Kennel 13 Door None 20 0.098 270 90 X Insulated Metal Door Kennel 14 Door None 40 0.098 270 90 X Insulated Metal Door Kennel FENESTRATION SURFACES # Type Area U -Val. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 22 0.870 270 0.70 Double Mtl Uncoated Default Room -Grooming EXTERIOR SHADING # Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Right Fin Len. Hat. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 Run Initiation Time: 11/08/00 12:53:27 Run Code: 973716807 EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:6 of 17 LIGHTING COMPLIANCE SUMMARY Performance LTG -1 PROJECT NAME Village Park Kennel and Grooming JDATE 11/8/2000 INSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire • Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # (Lam + Ballast Total Waw # ' . Watts 1 26w Compact Fluorescent Quad 2 Pin CF 26W/G24d-3 1 .26 Magnetic Standard 1.0 3 37.0 111 (1) 38w Compact Fluorescent 2D Elec CFS38W/GR10q 11 381 Electronic 1.01 7 37.0 259 60w Recessed Incandescent 60W 1 60 No Ballast 1 60.0 60 75w Recessed Incandescent 75W 1 75 No Ballast 5 75.0 375 k Subtotal from this Page 805 Building Total 805 Less Control Credit Watts (From LTG -3) Adjusted Actual Watts 805 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL -. IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) NOTE TO FIELD SPACE CONTROLLED CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL, IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIREC NT LLED NOTE TO FIELD TYPE # OF LUMINAIRES NOTES TO FIELD -Tor Building Department Use Only Run Initiation Time: 11/08/00 12:53:27 Run Code: 973716807 �-EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:7 of 17 CERTIFICATE OF COMPLIANCE Performance MECH-1 - PROJECT NAME Village Park Kennel and Groomin J DATE - 11 /8/2000 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 11/08/0012:53:27 Run Code: 973716807 EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:8 of 17 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME DATE Village Park Kennel and Grooming11/8/2000 ICHILLER AND TOWER SUMMARY RETURN Efficiency Tons PUMPS CFM BHP " Equipment Name Equipment Type Qty. Tot. Qty JGPM Blow -Through BHP Motor Eff. Drive Eff. Pump Control none 1QHW BOILER SUMMARY TANK INSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. O SMITH WATER PRODUCTS BTH-150-'.. Large Gas Standard 1 150,000 100 0.95 0.0102 0.0 CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. Output Aux. kW Eff. Out ut Sensible Efficiencv Economizer Type BDP CO. 661CJ042-' Split DX 1 42,000 7.5 7.2 HSPF 40,500 28,35010.0 SEER /9.0 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN System Name Fan Type CFM BHP Eff. Motor Drive Constant Volume Blow -Through Motor Drive 77.0% 100.0% none I EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Paoe:9 of 17 1 Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. BDP C0.661 CJ042 Constant Volume Blow -Through 1,400 0.25 77.0% 100.0% none MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 1 PROJECT NAME Village Park Kennel an ZONE TERMINAL SUMMARY DATE /8/2000 VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min. CFM Reheat Coil Flow Motor Drive Zone Name System Type Qty. Ratio Type DeltaT Ratio CFM BHP Eff. Eff. Type Output EXHAUSTFAN E HAUSTFAN Room Name CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM I BHP Motor Eff. Drive Eff. Grooming Room 1 400 0.03 77.0°/ 97.0% Kennel 2 400 0.03 77.0°/ 97.0% EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:10 of 17 1 VIECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Village Park Kennel and Grooming 11/8/2000 MECHANICAL VENTILATION a ©© a o o© a a o 0 ZONE/SYSTEM Grooming Room Kennel Kennel & Grooming AREA BASIS COND. VAV MIN. RATIO MIN. AREA CFM CFM (SF) PER SF , (B x C) 219 0.25 55 388 0.15 58 OCCUPANCY BASIS NO. CFM MIN. OF PER CFM PEOPLE PERSON (ExF) Total REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR 55 400 58 800 113 1,200 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page: 11 of 17 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 Village Park Kennel and Groomi DATE 11/8/2000 COMPONENT DESCRIPTION DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAME R-13 Wall w/1" EPS Insulation, Mineral Fiber, R-13 5 ASSEMBLY Floor 0.04 7 TYPE (check one) Wall 2.08 0 U.1 W Ceiling / Roof INSIDE SURFACE AIR FILM 0.680 FRAMING MATERIAL Wood Q FRAMING % 15 % Framing % 12.4 TOTAL HC 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) �.a CONSTRUCTION COMPONENTS FA -1 n SUBTOTA R -VALUE DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Polystyrene, Smooth Skin 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6 0.04 7 0.37 s 2.08 s 0.54 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) 4MING ❑ ❑ ❑ © ❑ El El 0.170 0.875 0.010 1.000 3.500 0.500 5.000 12.999 3.465 0.4501 0.450 SUBTOTA R -VALUE CAVITY. R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 5.000 5.000 12.999 3.465 0.4501 0.450 0.04 1.68 0.37 0.62 2.08 0.26 0.54 0.680 0.680 19.53 10.00 Rc Rf *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 0.0512 X 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 0.15 0.29 0.04 1.68 0.37 0.62 2.08 0.26 0.54 12.4 TOTAL HC 2 9 TE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members 0.0512 X 0.85 ] + [ 0.1000 X 0.15 1 / Rc° 1 - (Fr/° 1100) 1 / Rf J Fr/o / 100 ASSEMBLY U -NACU y EnergyPro 2.1 By EnregySoft User Number: 2248 Job Number: bdc010000 Page: 12 of 17 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 rROJECT NAME Village Park Kennel and Groomir tY1M r-jUMT IIFSCRIPTInN W DESCRIPTION 0 W 1 0 2 93.33 F— 18.67 4 Z O SKETCH OF ASSEMBLY I T DATE 11/8/2000 ASSEMBLY NAME 8" Concrete Wall ASSEMBLY Floor TYPE Wall (check (check one) Ceiling I Roof FRAMING MATERIAL None FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) 7% (24" o.c. Floor/Ceil.) R -VALUE CAVITY WOOD R -VALUE FRAME (Rc) R -VALUE 0.170 0.640 0.680 EI �W- *HEAT CAPACITY (Optional) DESCRIPTION SPECIFIC HEAT (Btu/F-Ib) OUTSIDE SURFACE AIR FILM 1 Concrete, 140 Ib, Not Dried 2 93.33 3 18.67 4 5 6 7 8 9 INSIDE SURFACE AIR FILM DATE 11/8/2000 ASSEMBLY NAME 8" Concrete Wall ASSEMBLY Floor TYPE Wall (check (check one) Ceiling I Roof FRAMING MATERIAL None FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) 7% (24" o.c. Floor/Ceil.) R -VALUE CAVITY WOOD R -VALUE FRAME (Rc) R -VALUE 0.170 0.640 0.680 EI �W- *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 93.33 0.201 18.67 SUBTOTA 1.491 TOTAL HC 18 7 Rc Rf ,TE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x �] + [� x 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% 1100 ASSEMBLY U-VALU Ener. yPro 2.1 By EnregySoft User Number: 2248 Job Number: bdc010000 Page:13 of 17 ENVELOPE MANDATORY MEASURES ENV - PROJECT NAME DATE Village Park Kennel and Grooming 11/8/2000 DESCRIPTION Designer Enforcement ❑X §118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X❑ §1`18(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. XI § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). 0 § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. R §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page:14 of 17 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME Village Park Kennel and Groomi DATE 11/8/2000 DESCRIPTION Designer Enforcement a § 131(d)1 Building Lighting Shut-off: The building lighting shut-off system consists of an automatic time switch, with a zone for each floor; or the building is separately metered and less than 5,000 square feet; exempt from the shut-off requirement. § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. E§ 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. aFluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. 0 § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. F§ 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 1.0 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. ❑ § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are ' continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. X❑ § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel. F § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page: 15 of 17 0 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Village Park Kennel -and Grooming 11/8/2000 DESCRIPTION Designer Enforcement . Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. XI § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. 0 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the. Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: Ir X71 § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; •and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or F] § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. X❑ § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling Is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page: 16 of 17 AECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MN PROJECT NAME VII I Park Kennel and Groomin DATE 11 /8/2000 Dti escripon Designer= Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or F] §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or 0 § 121(f)4 Another method approved by the Commission. Service Water Heating Systems ❑ § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 2.1 By EnergySoft User Number: 2248 Job Number: bdc010000 Page: 17 of 17