Loading...
AR (07-0062)44805 Los Manos Dr 07-0062 P.O. BO X 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 07-00000062 44805 LOS MANOS DR 604-272-010-114 -23913 - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 6467 Architect or Engineer: r • " BUILDING & SAFETY DEPARTMENT . BUILDING PERMIT ----------------- -------------------------------- LICENSED CONTRACTOR'S DECLARATION - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.): ( 1 I am exempt under Sec. , B.&P.C. for this reason t Date: I laic/ Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERAIIT Owner: RANDY/RENEE DIAZ 44805.LOS MANOS LA QUINTA, CA 92253 Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/09/07 Y °47 lDr, WORKER'S COMPENSATION DECLARA F. 1 hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compens , as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and'will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: . Carrier Policy Number _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I sho come subject to the workers' compensation provisions of Section . `! / r 3700 of the Labo ode, sho with comply with those Provisions. Date: f0 Applicant: WARNING: FAILURE TO SECURE A ' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to ' construction, and hereby authorize represeconstruction, and hereby authorize representatives of this co ty to enter upon the above-mentioned pr pert for ection purposes. Dater Signature (Applicant or Agent . Application Number . . . . . 07-00000062 ------ Structure Information 172SF GARAGE CONVERSION ----- Other struct info . . . . . CODE EDITION 2001/2005 # BEDROOMS 1.00 FLOOD ZONE NO 1ST FLOOR SQUARE FOOTAGE -------------------------------------------------=-------------------------- 172.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 90.00 Plan Check Fee 58.50 Issue Date . . . . Valuation .. 6467 Expiration Date 11/05/07 Qty Unit Charge Per Extension BASE FEE 45.00 5.00 9.0000 THOU BLDG 2,001-25,000 ------------------------------------=------------------------ 45.00 --------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 18.44 Plan Check Fee 4.61 Issue Date Valuation . . . . 0 Expiration Date 11/05/07 Qty Unit Charge Per Extension BASE FEE 15.00 172.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL ---------------------------------------------------------------------------- 3.44 Permit . . . MECHANICAL Additional desc . Permit Fee 19.50 Plan Check Fee 4.88 . Issue Date . . . . Valuation . . . 0 Expiration Date 11/05/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT =----------------------------------------- 4.50 ---------------------------------- Special Notes and Comments 172SF GAR. CONVERSION/V-NR/RES-3/CONV. 2001.CBC, CMC, 2005 ENERGY. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL AND SPA, OR DRIVEWAY APPROACH. May 2, 2007 .4:00:25PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 5.85 LQPERAIIT Application Number . . . . . 07-00000062 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES .64, Fee summary Charged ---------- Paid -------------------- Credited ---------- Due ----------------- Permit Fee Total 127.94 .00 .00 127.94 Plan Check Total. 67.99 .00 .00 67.99 Other Fee Total 6.49 .00 .00 6.49 Grand Total 202.42 .00. .00 202.42 LQPER1N4IT Bin,# fcoo City of La Quinta: Building u Safety Division Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #P.O. Vo Project Address: `►` d 5 /r'lQ f4 Os Owner's Name: P1.0nd 01 Rer e --e ZV z A. P. Number: 2. o Address: *ygo5 Los l v/ a,W s Legal Description: City, ST, Zip: L -.dally/• -29 64- 53 Contractor: O Address: Telephone; 760•- 5 7 - MY MMMlM Project Description: y„ City, ST, Zip: Telephone: , State Lic. # : City Lic. #: Arch., Engr., Designer: • Address: City, ST, Zip: Telephone: State Lic. #: Construction Type: Occupancy: P cY: Project type.(circle one): New Alter Repair Demo Name of Contact Person: ( Z ..Add'n Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: '760-- 679 Q FSS Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING . PERMIT FEES Z Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, readections Pian Check Deposit Truss Calcs. Called Contact Person , A 40 Plan Check Balance Energy Calcs. Pians picked up Y14/67 Construction Flood plain plan Plans resubmitted Mechanical Grading. plan2" Review, ready for correctio issu Electrical Subcontactor List Called Contact Person, Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted 4r44101 Grading IN HOUSE:- Review, ready for.correctionslissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees ► Q 1 7, ► Total Permit Fees Z . / VN 001,9X% L ivy /10U5tJ - ` C rw, I t*.(Uw V1 Puw CERTIFICATE OF COMPLIANCE NSZ4 C' Desert Sands Unified School District 2 47950 Dune Palms Road - 6q ERMUDADUNESO rn RANCHO MIRAGE CJ Date 5/3/07 La Quinta, CA 92253 N INDIAN WELLS No. 29397 (760) 771-8515 DESERT PALM LA QUOTA PINDIy 0 Owner Randy & Renee Diaz APN # 604-272-010 Address 44-805 Los Manos Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 44805 Los Manos Unit 2 Unit 3 Unit 4 Unit 5 Comments 172 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 172 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Randy Diaz Check No. Name on the check Telephone 200.9265 Funding Exempt By Dr, Doris Wilson Superintendent Fee collected /exempted by Son c Ilvr,-y Payment Recd_ $0.00 : Over/Ukeir. Signature C - NOTICE: Pursuant to Government Code Section 66020(d)(1), this wil rve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting TELEPHONE (760) 777-7012 FAX (760) 777-7011 OWNERBUILDER INFORMATION Dear Property Owner: An application for a building permit. has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations include State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. J For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contracts are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 760 )-277-70127 7011GO) /X: OWNER'S SIGNATURE/DATE 'YY- 905- 1---J5 PROPERTY ADDRESS PERMIT NUMBER(S) November 26, 2007 Mr. Randy Diaz 44805 Los Manos Drive La Quinta, CA 92253 F a rw BUILDING & SAFETY DEPARTMENT To use. c.41asjexT 1%) F11-6 RE: Building Permit Extension Request — 44805 Los Manos Drive. Dear Mr. Diaz: I have reviewed your letter dated November 9, 2007, requesting a time extension for the 172 square -foot garage conversion being constructed at the above address under Building Permit #07-0062. Our records indicate the following status on this project. Inspection status: Permit issued: 05/10/07 Last successful inspection: NONE 180 -day expiration date: 11/06/07 180 -day extension date: 05/05/08 Under the provisions of California Building Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once," please be advised that unless the project.passes its next required inspection'on or before Monday, May 5, 2008, your building permit will expire automatically. Yours truly, Greg Butler Building & Safety Manager P.O. BOX 1504 • LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO • LA QUINTA, CALIFORNIA 92253 (760) 777-7012 • FAX (760) 777-7011 November 9, 2007 Mr. Greg Butler Building & Safety City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Re: Building Permit No: 07-0062 For Address: 44805 Los Manos Drive in La Quinta Dear Mr. Butler: I received a building permit on May 10, 2007 for an addition to the above mentioned property. Due to unexpected delays, we have been unable to start any work on this project. I would like to request an extension. Thank you for your consideration -in this matter. I can be reached at (760) 578-8855. Sincerely, 4dy 44805 Los Manos Drive La Quinta, CA 92253 PIP' -Z ,679 -YE S ,.. 06 `1 I TITLE 24 REPORT I Title 24 Report for: Diaz Residence -Addition 44-805 Los Manos Drive La Q u i nta, CA 92253 Project Designer: Randy Diaz 44-805 Los Manos Drive La Quinta, Ca 92253 (760) 578-8855 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE.15higgY- lT9 Mod p APR 2 6 2007 I U By Date: 1 /3/2007 EtA 8,Pro computer program has been used to perform the calculations summarized in this compliarogram has approval and is by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. It. EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 1 en ti TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 10 11 12 EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 1 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R niaz Residence-Add9tinn 198 ft2 Existing Floor Area: 113/2007 o.ect Title Raised Floor Area: 0 ft2 Date -81715 1 ns Mans nrlye La Quints Average Ceiling Height: 9.0 ft Project Address 0.15 Number of Stories: Building Permit # ntt Design & Title 24 (760) 200-4780 _, Documentation Author Telephone Plan Check/Date FneravPrn CompliNrice Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.84 2.73 1.11 Space Cooling 102.37 99.43 2.94 Fans 14.66 14.24 0.42 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 120.86 116.40 4.47 Percent better than Standard: 3.7% Building Type: (J Single Family Q Addition ❑ Multi Family ❑ Existing .+ Add/Alt Building Front Orientation: (E) 90 deg Fuel Type: Natural Gas Fenestration: Area: 20 ft2 Avg. U: 0.58 Ratio: 10.1% Avg. 'SHGC: 0.46 ILDING ZONE INFORMATION _ ie Name Floor Area Volume Units Zone Type HVA ,-1 19R 7R2 n 15 Conditioned Total Conditioned Floor Area: 198 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 198 ft2 Average Ceiling Height: 9.0 ft Number of Dwelling Units: 0.15 Number of Stories: 1 # of OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnof Wnnd 19R n n25_ R_38 R-0 0 _n ?n Wall Wood 162 0.074 R_19 R-0.0 n Arl Wall Wood 79 0.074 R-19 R-0.0 AQ—gn Wall Wnnd 167 n n74 R_19 R-0 0 1Rn go Thermostat Vent Type Hgt. Area Sethack —nla Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑New 01-A1R Additinn IN ❑New 09-A5 Addition IN ❑New 09-A5 Addition IN ❑New 09-A.5 Additinn EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Pane:3 of 12 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R , Diaz Residence -Addition 1/3/2007 ject Title Date True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments J— Window Front (E) _ 20 0 0 58 NFRC- –0A6 NFRC _g0_ gyp_ New Double Non -Metal Tinted Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 29 None No Insulation 26-A1 New Addition Run Initiation Time: 01/03/07 11:56:19 Run Code: 1167854179 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:4 of 12 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R , iaz Reside nce-Additi Title AG SYSTEMS 1/3/2007 Date Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -1 Ducted Ducted Attic 4.2 Existing Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Randy Diaz Address: 44-805 Los Manos Drive La Quinta Ca 92253 Telephone: 760 8-885 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: User Number: 6712 Documentation Author Name: Tim Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Palm De ertCA 9 211 Telephone: 7 -4780 ! 3 (9 (signature) I (date) ., Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R .l Title 11312007 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the aaequacy OT ine special fusuTicauon ana aocumentation suomittea. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- -approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R plan Field installation certificate. e HVAC System "HVAC -1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF4R. V Run Initiation Time: 01/03/07 11:56:19 Run Code: 1167854179 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:6 of 12 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R ) NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. t' r DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El a E)CF-6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:7 of 12 .• Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1'19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:8 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY `I PROJECT NAME DATE Diaz Residence -Addition 1/3/2007 STEM NAME FLOOR AREA HVAC -1 198 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 292 5,620 983 104 3,655 0 887 423 0 0 0 0 0 0 0 0 0 887 423 7,3 983 4.5001 HVAC EQUIPMENT SELECTION Existing HVAC System 40,280 12,506 71,000 Total Adjusted System Output x0,280 12,506 71,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.8 of 69.8 of 103.2 of O Supply Air Ducts Outside Air 0 cfm 103.0 of Supply Fan Heating Coil 2000 cfm ROOMS 69.8 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS 111.0/77.6OF 78.4/65.1OF 310 Outside Air 0 0 cfm Supply Fa 2000 cfm 78.4/65.1 of Airstream Temperatures at Time of CoolingPeak 78.4 / 65.1 of 59.5 / 58.4 of Supply Air Ducts Fan Cooling Coil 59.9 / 58.6 of 49.9% R.H. ROOMS 78.0/64.9OF Return Air Ducts 4.2 by EnergySoft User Number: 6712 Job Number: Paae:9 of 12 ROOM LOAD SUMMARY t PROJECT NAME Diaz Residence -Addition DATE 1/3/2007 STEM NAME HVAC -1 FLOOR AREA 198 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 292 5,620 983 292 5,620 983 104 3,655 r PAGE TOTAL 1 292 5,620 983 104 3,655 TOTAL 1 292 5,620 9831F-1041 3,655 EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 12 ROOM HEATING PEAK LOADS Project Title Date az Residence -Addition 11/3/2007 oom Information Desi n Conditions Room Name Addition Time of Peak Jan 12 am Floor Area 198 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 198.0 x X X x X x x X X x x x X X X X X x X X X X X x X X x X X X X X X X X X X x x 0.0250 X X X X X X x x x X X x x X X X x x X X X X X X x X X X x x X X X X X x x x X 44 = = = = = = = = = = = = = = = = 218 162.0 0.0740 44 527 79.0 0.0740 44 257 20.0 0.5800 44 510 162.0 0.0740 44 527 perimeter = 29.0 0.7300 44 931 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 2 972 Infiltration: r .001 X 1.064 X 198 X 9.00 x 0.491 / 60] X = 683 schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 3,655 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 11 of 12 RESIDENTIAL ROOM COOLING LOAD SUMMARY ro.ect Title Date iaz Residence -Addition 1/3/2007 Room Information Desi n Conditions Room Name: Addition Outdoor Dry Bulb Temperature: 112o17 Floor Area: 198 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • 19 Wall N 198.0 X X X X X X X X x x x X 0.0250 X X X X x X X x X X X X 77.0 = = = = = = = N 162.0 0.0740 31.0 E 79.0 0.0740 44.0 S 162.0 0.0740 38.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Nage I otal 381 372 257 456 1 466 Orientation 920 Shaded Area X X X x X X x X x X x GLF + + + + + + + + + + + Unshaded Area x X X x x x X X X X X Page GLF = = = Btu/hr E 0.0 34.4 20.0 75.3 1,507 983 Total 1 507 Btu/hr x Occupants X 230 Btuh/occ. = 920 X Dwelling Units x 1,2001 Watts/sqft = 1 200 Infiltration: 1.064 X 1.16 X 12.55 x Air Sensible CFM ELA OT F 528 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5620 Latent Gain Occupants 0 x Occupants x 200 Btuh/occ. = Btu/hr 800 Infiltration: 4 771 x 1.16 x 12.55 x 0.00263 = 183 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 983 Occu ants E ui ment 1 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 12 of 12 I C 55;1r of %: -: y.0 ti2 \\ o rnment Code #oiidays: ` one 2—SITE PLAN ."TRUCnON 3—FOUNDATION H o0 \ i % - ber4st - April 30 lay Friday: 7:00 a.m. to 0 p.m A ' • 8:00 am. to 5:00 R O ay: \ None E rnmeni Code Holidays: 1st - SeptVmber 30th . lay - Friday: 6:00 a.m. to 7:00 p. -day: 8,:00 am. to S:P P.M. %: -: ay. Qne .of rnment Code #oiidays: ` one 2—SITE PLAN ."TRUCnON 3—FOUNDATION H o0 \ i ber4st - April 30 lay Friday: 7:00 a.m. to 0 p.m A ' • 8:00 am. to 5:00 R O ay: \ None E rnmeni Code Holidays: 1st - SeptVmber 30th . lay - Friday: 6:00 a.m. to 7:00 p. -day: 8,:00 am. to S:P P.M. EXISTING AC. DUCT (TIE IN) Construction is NOT PERM on the following Code Holidays: New Year's Day "\ \ Dr. Martin Luther Wnglr. Day \AIRGED President s DayRE-I FEE OF $31 Memorial Day ILL BE RUE APPROVEI Independence Day Labor Day P NS AN (36 CARCARQnA, RE NOT OF p kP \ Veteran s 0a ►r\ TH -$ FOR A\ HEDULEE so \ ,T rdCsgiving Dax 4N CTION. ✓' F, 4N ` NO EPi10 S. »'Christmas Da \ A N ­4 - i f ADEQUATELY IZED DEBRIS COMINER i' REQUIRED ON THE 10B S E DURIN&LL "'LASES OF CONST CTION IND MUT BE 6SIECESSA Y. FAILRE TO D SO s F y ;OAY CAUS , ITY TO HAVE THE CONTAI R DUMPED A CONTRACTORE EN OF TH OWNE \ i i C) ay. Qne .of rnment Code #oiidays: ` one 2—SITE PLAN \ o 3—FOUNDATION SHT 4—ELECTRICAL LEGE 0 RFCI—RECEPkTACLE 0 GFI-RECEPTACLE A PHONE OUTLET LIGHT OUTLET \ $ SINGLE SWITCH \ • CABLE OUTLET \ © SMOKE DETECTOR \ EXISTING WALL \ PROPOSED WALL \ ==== EX. AC DUCT/VENT • EMERGENCY/EXIT ROUE 1' PROP. AC DUCT/VENT 0 DRAINAGE PATTERN \ 0 DRAINAGE LINE \ EXISTING AC. DUCT (TIE IN) Construction is NOT PERM on the following Code Holidays: New Year's Day "\ \ Dr. Martin Luther Wnglr. Day \AIRGED President s DayRE-I FEE OF $31 Memorial Day ILL BE RUE APPROVEI Independence Day Labor Day P NS AN (36 CARCARQnA, RE NOT OF p kP \ Veteran s 0a ►r\ TH -$ FOR A\ HEDULEE so \ ,T rdCsgiving Dax 4N CTION. ✓' F, 4N ` NO EPi10 S. »'Christmas Da \ A N ­4 - i f ADEQUATELY IZED DEBRIS COMINER i' REQUIRED ON THE 10B S E DURIN&LL "'LASES OF CONST CTION IND MUT BE 6SIECESSA Y. FAILRE TO D SO s F y ;OAY CAUS , ITY TO HAVE THE CONTAI R DUMPED A CONTRACTORE EN OF TH OWNE \ i i C) SHEET INDEX SHT 1—FLOOR PLAN SHT 2—SITE PLAN SHT 3—FOUNDATION SHT 4—ELECTRICAL SH.T 5—ELEV. (EXISTING) SHT 6—ELEV. (PROP.) SHT 7—DETAILS EXISTING AC. DUCT (TIE IN) Construction is NOT PERM on the following Code Holidays: New Year's Day "\ \ Dr. Martin Luther Wnglr. Day \AIRGED President s DayRE-I FEE OF $31 Memorial Day ILL BE RUE APPROVEI Independence Day Labor Day P NS AN (36 CARCARQnA, RE NOT OF p kP \ Veteran s 0a ►r\ TH -$ FOR A\ HEDULEE so \ ,T rdCsgiving Dax 4N CTION. ✓' F, 4N ` NO EPi10 S. »'Christmas Da \ A N ­4 - i f ADEQUATELY IZED DEBRIS COMINER i' REQUIRED ON THE 10B S E DURIN&LL "'LASES OF CONST CTION IND MUT BE 6SIECESSA Y. FAILRE TO D SO s F y ;OAY CAUS , ITY TO HAVE THE CONTAI R DUMPED A CONTRACTORE EN OF TH OWNE \ i i C) NOTE: ** ALL GARAGE FLOORING (EXISTING) ** ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, 2004 ELECTRICAL, AND 2005 ENERGY CODES AND ALL OTHER LOCAL CODES AND ORDINANCE. ** ALUMINUM CONDUCTORS ARE PERMITED IF SIZE Yo OR LARGER FOR MAIN OR SUB -PANEL FEED. ALL OTHER CONDUCTORS SHALL BE COPPER. ** SMOKE ALARMS SHALL BE 120—VOLT WITH BATTERY BACKUP. ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC -STANDARDS FOR CONVENTIONAL LIGHT—FRAME CONSTRUCTION. ** BRANCH CIRCUITS THAT SUPPLY 125—VOLT, SINGLE PHASE, 15—AND 20 AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOM SHALL BE PROTECTED BY AN ARC—FAULT CIRCUIT INTERRUPTER. / PROPOSED 12" X 12' REGISTER Q a ESS/ Q yO wATSOFy v No. 26662 m MARCH 31, 2008 CIVIV PROPOSED 10" AC DUCT (PER ENERGY CALCS) CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA 5 0+ SCALE: 1/4" = 1' 0 2 4 8 12 # REVISIONS BY DATE PREPARER: W & W DESIGN DEVELOPMENT INC,. DRAWN BY: DR CHECKED BY: LWW- - 77Y't zll DATE: 4- SCALE: AS SHOWN DATE: APRIL 3, 2 : ,KOY5 W. WATSON LOCATION: 79-440 CORP. CNTR. DR. ST -107 FLOOR PLAN PH: -(760)771-6237 FAX: (760)771-6238 GARAGE/GUEST RE—MODEL JOB -NAME: DIAZ RESIDENCE 172 S.F. CONVERSION 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 JOB W/O NO.: SHEET 1 OF 7 V 1- / Owl .+ SCALE: 3/32" = 1' 0 5' 10' 16' 32' NOTE: ** ALL GARAGE FLOORING (EXISTING) ** ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, 2004 ELECTRICAL, AND 2005 ENERGY CODES AND ALL OTHER LOCAL CODES AND ORDINANCE. ** ALUMINUM CONDUCTORS ARE PERMITED IF SIZE Yo OR LARGER FOR MAIN OR SUB -PANEL FEED. ALL OTHER CONDUCTORS SHALL BE COPPER. ** SMOKE ALARMS SHALL BE 120—VOLT WITH BATTERY BACKUP. ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC -STANDARDS FOR CONVENTIONAL LIGHT—FRAME CONSTRUCTION. ** BRANCH CIRCUITS THAT SUPPLY 125—VOLT, SINGLE PHASE, 15—AND 20 AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOM SHALL BE PROTECTED BY AN ARC—FAULT CIRCUIT INTERRUPTER. / PROPOSED 12" X 12' REGISTER Q a ESS/ Q yO wATSOFy v No. 26662 m MARCH 31, 2008 CIVIV PROPOSED 10" AC DUCT (PER ENERGY CALCS) CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA 5 0+ SCALE: 1/4" = 1' 0 2 4 8 12 # REVISIONS BY DATE PREPARER: W & W DESIGN DEVELOPMENT INC,. DRAWN BY: DR CHECKED BY: LWW- - 77Y't zll DATE: 4- SCALE: AS SHOWN DATE: APRIL 3, 2 : ,KOY5 W. WATSON LOCATION: 79-440 CORP. CNTR. DR. ST -107 FLOOR PLAN PH: -(760)771-6237 FAX: (760)771-6238 GARAGE/GUEST RE—MODEL JOB -NAME: DIAZ RESIDENCE 172 S.F. CONVERSION 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 JOB W/O NO.: SHEET 1 OF 7 c`f EX. BLOCK WALL , ' / NOTE: \ 44 ' \ ** ALL GARAGE FLOORING (EIS TING) ALL CONSTRUCTION SHALL \COMPLY WITH THE 2001 CALIFORNIA BUIL NG, % fA / PLUMBING, MECHANICAL, 004 ELECTRICAL, AND 2005 ENERGY COD S AND ALL G OTHER LOCAL CODES AND ORDINANCE. ALUMINUM CONDUCTORS ARE PERMITED IF SIZE Yo OR LARGER FOR MAI OR SUB—PANEL FEED. ALL OTHLR CONDUCTORS SHALL BE COPPER. Ia ® X \ir SMOKE ALARMS SHALL BE 120 VOLT WITH BATTERY BACKUP. THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC STAND RDS FOR CONVENTIONAL LIGHT—FR ME CONSTRUCTION. BRANCH CIRCUITS THAT SUPPLY 25—VOLT, SINGLE PHASE, 15—AND 20 A EREOUTLETS INSTALLED IN DWELLINq UNIT BEDROOM SHALL BE PROTECTED B AN ARC—FAULT CIRCUIT INTERRUPTER. 0 40 ® 1 \ LEGEND db. RFCI—RECEPTACLE dIb GFI—RECEPTACLE\ \ PHONE OUTLET \F ® 15—AMP CIRCUIT PROPOSED LIGHT OUTLET \ ® \ " $ SINGLE SWITCH \ ® FOR GUEST SUITE \ • CABLE OUTLET \ ® SMOKE DETECTOR \ / ® ADDITION (SEE NOTES **) ® 079 NF" EXISTING WALL \ PROPOSED WALL \ === AC DUCT/VENT \ ®® • ► EMERGENCY/EXIT ROUTE ® / co 0 DRAINAGE PATTERN \ , I 0 DRAINAGE LINE l EX. BLOCK WALL r SHEET INDEX , SHT 1 -FLOOR PLAN SHT . 2 -SITE PLAN SHT 3 -FOUNDATION SHT 4 -ELECTRICAL SHT 5-ELEV. (EXISTING) SHT 6-ELEV. (PROP.) SHT 7 -DETAILS EX. PROPERTY LINE W.Wgr 2 No. 26662 MARCH 31, 2008 CIVIL # REVISIONS BY DATE PREPARER: W & W DESIGN DEVELOPMENT INC,. DATE: 0 W. WATSON LOCATION: 79-440 CORP. CNTR. DR. ST -107 PH: (760)771-6237 FAX: (760)771-6238 JOB NAME: DIAZ RESIDENCE 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 CITY OF k BUILDING.& APPR FOR CONS DATE BY QUINTA =ETY DEPT. VE -D. .. -SCALE: 3Y32 DRAWN BY: DR CHECKED BY: LWW SCALE: AS SHOWN DATE: APRIL 3, 2007 SITEPLAN GARAGE/GUEST RE -MODEL 172 S.F. CONVERSION JOB W/O NO.: I SHEET 2 OF 7 It SHEET INDEX SHT LEGEND 0 RFCI—RECEPTACLE 0 GFI—RECEPTACLE Z PHONE OUTLET SHT LIGHT OUTLET $ SINGLE SWITCH • CABLE OUTLET © SMOKE DETECTOR EXISTING WALL PROPOSED WALL =_== AC DUCT/VENT • •► EMERGENCY/EXIT ROUT 0 DRAINAGE PATTERN 0 DRAINAGE LINE SHEET INDEX SHT 1 -FLOOR PLAN SHT 2 -SITE PLAN SHT 3 -FOUNDATION SHT 4 -ELECTRICAL SHT 5-ELEV. (EXISTING) SHT 6-ELEV. (PROP.) SHT 7 -DETAILS NOTE: \ ** ALL GARAGE FLOORING (EXISTING) ** ALL CONSTRUCTION SHALL COMPLY WITHE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, 2004 ELEC ICAL, AND 2005 ENERGY CODES AND AL OTHER LOCAL CODES AND ORDINANCE. ALUMINUM CONDUCTORS ARE PERMITED I,F SIZE Yo OR LARGER FOR MAIN OR SUB—PANEL FEED. ALL OTHER CONDUC ORS SHALL BE COPPER. ** SMOKE ALARMS SHALL BE 120—VOLT WIT BATTERY BACKUP. ** HIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC STANDARDS FOR CONVENTIONAL LIGHT—FRAME CONST UCTION. ** B ANCH CIRCUITS THAT SUPPLY 125—VOLT, SINGLE PHASE, 15—AND 20 AMPERE UTLETS INSTALLED IN DWELLING UNIT BEOR00M SHALL BE PROTECTED BY AN A C—FAULT CIRCUIT INTERRUPTER. l "l QRpFESS/oN :, Q oyp N • WgTs y cit v G No. 26662 m Lu MARCH 31, 2008 za -Civil.- REVISIONS iV11. REVISIONS BY I DATE PREPARER: W & W DESIGN DEVELOPMENT INC,. DATE: 0 W. WATSON LOCATION: 79-440 CORP. CNTR. DR. ST -107 PH: (760)771-6237 FAX: (760)771-6238 CITY OF LA QUINTAf BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY SCALE: 3/32" = 1' 0 5' 10' 16' 32' DRAWN BY: DR CHECKED BY: LWW SCALE: AS SHOWN DATE: APRIL 3, 2007 JOB NAME: DIAZ RESIDENCE 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 JOB FOUNDATION PLAN GARAGE/GUEST RE -MODEL 172 S.F. CONVERSION W/O NO.: I SHEET 3 OF 7 I WINDOW SCEDULE SYM.1 SIZE TYPE QTY. W1 5'X3.5' HORIZONTAL SLIDING 1 D2 6'X 6'8" BYPASS DOOR 1 DOOR SCEDULE SYM. SIZE TYPE QTY. D1 5'X 6'8" HORIZONTAL SLIDING 1 D2 6'X 6'8" BYPASS DOOR 1 LEGEND 0 RFCI-RECEPTACLE 0 GFI-RECEPTACLE A PHONE OUTLET ¢ LIGHT OUTLET $ SINGLE SWITCH • CABLE OUTLET Q SMOKE DETECTOR EXISTING WALL PROPOSED WALL ::CD=: EX. AC DUCT/VENT ♦0--w EMERGENCY/EXIT PROP. AC DUCT/VENT E 0 DRAINAGE PATTERN 0 DRAINAGE LINE v O \\ EXISTING AC. DUCT (TIE IN) a \\ \\ v o \\ o a w SEE DETAIL`S ,t A„ 1' ,oR.. lw SEE DETAI: ".,\ „c., G -SEE DETAIL „D„ G „B \ \A ' ED`S P EN / OPpSvo 6': `''' W 1 2 2 0 AN ' E `S \NG pS\OO pppR NOTE: \\ \\ \ u c ALL GARAGE FLOORING (EXISTING) QFES$/C ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, 2004 ELECTRICAL, AND 2005 ENERGY CODES AND ALL Q y0 ATs F2 OTHER LOCAL CODES AND ORDINANCE. a v O ** ALUMINUM CONDUCTORS ARE PERMITED IF SIZE 1/0 OR LARGER FOR MAIN OR y ~ 2, Z SCALE: 1/4" = 1' SUB -PANEL FEED. ALL OTHER CONDUCTORS SHALL BE COPPER. w N0.26662 m ** SMOKE ALARMS SHALL BE 120- VOLT WITH BATTERY BACKUP. cc MARCH 31, 2008 ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC STANDARDS 0 2' 4' 8' 12' FOR CONVENTIONAL LIGHT -FRAME CONSTRUCTION. S SHEET INDEX ** BRANCH CIRCUITS THAT SUPPLY 125 -VOLT, SINGLE PHASE, 15 -AND 20 AMPERE l'gTcc CAVIL OUTLETS INSTALLED IN DWELLING UNIT BEDROOM SHALL BE PROTECTED BY AN OFCAL F SHT 1 -FLOOR PLAN ARC -FAULT CIRCUIT INTERRUPTER. 1” ®®eP \ SEE DETAIL » C, $ \00ow- ♦I (2) 5/8" TYPE "X" 1 DRYWALL FIREWALL BETWEEN GARAGE AND PROPOSED GUEST SUITE spy" f -F LA QUI NTA oS`0 o ^ CITY O BUILDING & SAFETY pWf-T- APPROV FOR CONSTRUCTION DATE BY SCALE: 1/4" = 1' 2' 4' 8' 7 SHT 2 -SITE PLAN # REVISIONS BY DATE PREPARER: W & W DESIGN DEVELOPMENT INC,. DATE: LLO IN. WATSON LOCATION: .79-440 CORP. CNTR. DR. ST -107 PH: (760)771-6237 FAX: (760)771-6238 DRAWN BY: DR CHECKED BY: LWW SHT 3 -FOUNDATION SCALE: AS SHOWN DATE: APRIL 3, 2007 SHT 4 -ELECTRICAL ELECTRICAL PLAN GARAGE/GUEST RE -MODEL 172 S.F. CONVERSION SHT 5-ELEV. (EXISTING) SHT 6-ELEV. (PROP.) JOB NAME: DIAZ RESIDENCE 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 SHT 7 -DETAILS JOB W/O NO.: SHEET 4 OF 7 y •i' `i{ •t ,i, `iia-. { `" •i' `i 'i'rI'`1 `I' `i `i' •[ `i '{ •i' q `f `4 1 -`is.-`' yr `;;4-ijr !, _ -, ,. ,r::iG:`i%- :'.' ' ' s _ 1Ic•i .;{ ,it •i' •t • y''7 ', t' _7,'y ' ;' ; , t• ,•T `,3,j$ - ,-,"p ' ' ",'`; -;r` •;Te`•,"f 4?t';`'y, r •Ti's;-a-r '-'.,'. 77 f k f 3.5 9.5'.'`::'...:'.:...;:......:...:.....:.•.;:;;;:;•::::'.•:•.':•'•':•:::'•:•:'•:.:':::'.:.'•'•:.:.:''•:.::.:'.'.''•:•.•:'.'.:•:•:•:•:•::':•::.•:•:•:•:•.::•.'..•:•:•:::'•.::'•:::..::'.:•':•::•'•:::..'•':•::•'•:':'.:••:.::•.'..•:•'.•::':•.':'.•:•:•.':•:.::'..:::.::'•.:::.::'.:'•:.'':'.:':'•.::'.:':'•:::'.:•':..'....':•::•:•.'..•:•:'•:•':•:•.•:•.•::.•.::•:•:•:•.•:•`•.:.•:•:•:•'•'::•:•••:••::•:•:•:'.:•,'•:::'.:.:'.:::'.::':•:•.':•.'•.'.:':'•.':::•::'.•.'.':.:.'..:.:'.:.'...: NOTE: ** ALL GARAGE FLOORING (EXISTING) ** oQROFESSA WgP'S't ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, ,L 2004 ELECTRICAL, AND 2005 ENERGY CODES AND ALL OTHER LOCAL CODES AND ORDINANCE. Qy VV. v O O ** ALUMINUM CONDUCTORS ARE PERMITED IF SIZE 1/0 OR LARGER FOR MAIN OR SUB—PANEL FEED. ALL v N0.26662 m OTHER CONDUCTORS SHALL BE COPPER. .2 w m ** SMOKE ALARMS SHALL BE 120—VOLT WITH BATTERY BACKUP. rt MARCH 31, 2008 x ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC STANDARDS FOR CONVENTIONAL k Ott LIGHT -FRAME CONSTRUCTION. ** BRANCH SINGLE SHEET INDEX NIT PHASE,DANO E OUTLETS AMPEFAULLT INSTAL EIDCNITDWELLING UTHAT BEDROOMLSHALL BE PROTECTED BY, RC CIRCUIT T rF CA F \P INTERRUPTER. SHT 1 -FLOOR PLAN SHT 2 -SITE PLAN I # I REVISIONS SHT 3 -FOUNDATION SHT 4 -ELECTRICAL SHT 5-ELEV. (EXISTING) SHT 6-ELEV. (PROP.) SHT 7 -DETAILS BY DATE PREPARER: W & W QDESIGN 0 W. WATSON LOCATION: 79-440 CORP. PH: (760)771-6237 FAX JOB NAME: DIAZ RESIDENCE 44-805 LOS MANOS DRIVE, CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA DEVELOPMENT INC,. DRAWN BY: DR CHECKED BY: LWW DATE: EAl-02 SCALE: AS SHOWN DATE: APRIL 3, 2007 CNTR. DR. ST -107 EXTERIOR ELEVATIONS (EXISTING) (760)771-6238 GARAGE/GUEST RE -MODEL 172 S.F. CONVERSION LA OUINTA, CA 922531 JOB W/O NO.: I SHEET 5. OF 7 J 0 17' NOTE: ** ALL GARAGE FLOORING (EXISTING) ** ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, 2004 ELECTRICAL, AND 2005 ENERGY CODES AND ALL OTHER LOCAL CODES AND ORDINANCE. ** ALUMINUM CONDUCTORS ARE PERMITED IF SIZE Yo OR LARGER FOR MAIN OR SUB—PANEL FEED. ALL OTHER CONDUCTORS SHALL BE COPPER. ** SMOKE ALARMS SHALL BE 120—VOLT WITH BATTERY BACKUP. ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC STANDARDS FOR CONVENTIONAL LIGHT—FRAME CONSTRUCTION. . ** BRANCH CIRCUITS THAT SUPPLY 125—VOLT; SINGLE PHASE, 15—AND 20 AMPERE OUTLETS SHEET INDEX INSTALLED IN DWELLING UNIT BEDROOM SHALL BE PROTECTED BY AN ARC—FAULT CIRCUIT INTERRUPTER. SHT 1 -FLOOR PLAN L_ SHT2-SITE PLAN SHT 3 -FOUNDATION SHT 4 -ELECTRICAL SHT 5-ELEV. (EXISTING SHT 6-ELEV. (PROP.) SHT 7 -DETAILS W. No. 26662. lm MARCH 31, 2008 civil. F CAI: # REVISIONS BY DATE PREPA ER: W &/W/DESIGN DEVELOPMENT INC,. DATE: s o> Y W. WATSON SON CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION w DRAWN BY: DR CHECKED BY: LWW SCALE: AS SHOWN DATE: APRIL 3, 20071 LOCATION: 79-440 CORP. CNTR. DR. ST -107 EXTERIOR ELEVATIONS (PROPOSED) PH: (760)771-6237 FAX: (760)771-6238 GARAGE/GUEST RE -MODEL JOB NAME: DIAZ RESIDENCE 172 S.F. CONVERSION 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 JOB W/O NO.: SHEET 6 OF 7 EX. PROP. 112" EX. 1/2" EX. 1/2" PROP. 1/2" DOUBLE TOP PLATE DRYWALL DRYWALL DRYWALLDRYWALL —--------------------------------- --, EXISTING EX. 1/2" DRYWALL CRIPPLE E PROP.= ------------------ —tt=== __-__= CEILING—RAFTERS 4"X6" HEADER _ u u PROPOSED - it --- i -----11 -----------il -- - -- i-- --- - I i it i ---- -CRIPPLE li DOUBLE TOP -PLATE I I II I tl II II I , , EXISTING ,, ,, PROPOSED EX. FRAMING ,, , , „ EX. FRAMING 1 „ 11 II +I INSULATION 6"X8" HEADER ,i CONSTRUCT PROPOSED r-- ii (R-19) 8'-6' I „ INSULATION I1 II 8'-6" FIREWALL I EX. FIREBLOCKING 11 i I PROP. ' r==—iI i+ BLOCKING (R-19) li Ir-- PROPOSED I 1 I it TRIMMER STUD IL_ --I 1 - EXISTING i II I + II FIRE -BLOCKING CITY OF LA QUI TA EX. INSULATION II I PROP. I II INSULATION i ii i+ li II BUILDING & SAFETY DEPT. EX. INSULATION i u 1i 24" CRIPPLE II +1 p \,C (R-19) I I TRIMMER STUD I li ({x_19) R-19 PROPOSED (2) APPROVED 11 I I II ( ) I I ii i1 O.C. ii i 5/8" TYPE 'Y' V C EXISTING 1 I 1 u EXTERIOR FINISH ' I II it II +I DRYWALL FOR CONSTRUCTION EX. SOLE PLATE _ 48" FF — —_ 1 GFF Gi DATE 8Y PROPOSED ' -- T-- ------------------- 1- - EXISTING GFF S GFF SOLE PLATES PROPOSED 0. C. SOLE PLATES EX. ANCHOR -2 EX. ANCHOR CURB PROPOSED EXISTING PROPOSED INTERIOR WALL A CURB. SOLE PLATE CURB SECTION PROP.(2) 5/8" TYPE "X"PROP. %" TYPE "X" PROP.(2) 5/8" TYPE 'Y' EX. 1/2" PROP. 1/2" NOTE: DRYWALL DRYWALL DRYWALL ----- DRYWAL-L------ --DR-Y-WALL----- ** ALL GARAGE FLOORING (EXISTING) —Wn monnni amn n finom I nnormonfloominn _- _-_-- _- _-_---_ ** ALL CONSTRUCTION SHALL COMPLY WITH THE 2001 CALIFORNIA BUILDING, ------------------------------ ___ PUL __ _ _ PLUMBING, MECHANICAL, 2004 ELECTRICAL, AND 2005 ENERGY CODES AND EX. 5/8" TYKE ' i 'i ALL OTHER LOCAL CODES AND ORDINANCE. "X" DRYWALL - - ,i it ALUMINUM CONDUCTORS ARE PERMITED IF SIZE 1/0 OR LARGER FOR MAIN ,1 11 CRIPPLE +I +1 OR SUB—PANEL FEED. ALL OTHER CONDUCTORS SHALL BE COPPER. •CON TT PROPOSED 6"X8" HEADER ii ii ** SMOKE ALARMS SHALL BE 120—VOLT WITH BATTERY BACKUP. FIREW-WINDOW +I II ** THIS PROJECT IS PROPOSED TO MEET THE REQUIREMENTS OF CBC EX. BLOCKING IL__ 1 1 __JI V. INSULATION I --11 PROPOSED Ir --,I STANDARDS FOR CONVENTIONAL LIGHT—FRAME CONSTRUCTION. 1+ 11 CONSTRUCT II 8' 8'-6" [INSULATION:'II ** BRANCH CIRCUITS THAT SUPPLY 125—VOLT, SINGLE PHASE, 15—AND 20 24" ' ,, FIREWALL (R-19) " ' — AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOM SHALL BE 24" 8'-6' — I 11 BLOCKING +1 'F C 0. C. it li i PROTECTED BY AN ARC—FAULT CIRCUIT INTERRUPTER. PROPOSED Ii II 1, II • PROPOSED INSULATION ii 24 CRIPPLE I Q pFESS/ INSULATION (R-19) ,1 II 0. C. II 11 N (R-19) PROPOSED ii i Q OyQ 9 FF SOFFIT = - y °22 % LEGEND GFF 48" GFF c7 N0.26662 m EXISTING WALL GFF 48" 48" PROP. GFF 2' 6' m Qb RFCI-RECEPTACLE MARCH 31, 2008 PROPOSED WALL PROP. ANCHOR PROPOSED O.C. * Ub GFI—RECEPTACLE EX. AC DUCT/VENT ANCHOR O.C. O.C. CURB PROPOSED ♦ PHONE OUTLET ,y EMERGENCY/EXIT ROUTE SOLE PLATE cS'j, CIVIL Q. LIGHT OUTLET PROP. AC DUCT/VENT SHEET INDEX aT41F CA1. F $ SINGLE SWITCH 0 DRAINAGE PATTERN GARAGE WALL C EXTERIOR WALL D • CABLE OUTLET SHT 1- FLOOR PLAN1-0 SMOKE DETECTOR O DRAINAGE LINE -SHT 2 -SITE PLAN # REVISIONS BY DATE PREPARER: ,W >>& W DESIGN DEVELOPMENT INC,. DRAWN BY: DR CHECKED BY: LWW SHT 3 -FOUNDATION Gt/G%U DATE: 5 o> SCALE: AS SHOWN DATE: APRIL .3, 2007 SHT 4 -ELECTRICAL 16YEr W. WATSON LOCATION: 79 -440 -CORP. CNTR. DR. ST -107 DETAILS SHT 5-ELEV. (EXISTING) PH: (760)771-6237 FAX: (760)771-6238 GARAGE/GUEST RE -MODEL SHT 6-ELEV. (PROP.) JOB NAME: DIAZ RESIDENCE 172 S.F. CONVERSION SHT 7 -DETAILS 44-805 LOS MANOS DRIVE, LA QUINTA, CA 92253 JOB W/O NO.: I SHEET 7 OF 7