Loading...
BLCK (07-0308)51911 Madison St 07-0308 .' L . Ts • I P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00000308- . Property Address: 'k, 51911 --MADISON ST APN: 777-030-005- - - Application description: WALL/FENCE Property Zoning: VERY LOW DENSITY RES Application valuation: 20000 'Applicant: Architect or Engineer, 4 f Gl dt/ BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ---------------------------------------------- / LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B C29 LicenseNo.: 820821 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt fromrthe Contractor's.State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter•9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for•sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of 'property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - (_) I am exempt under Sec. , B.&P.C. for this reason 91 9n ate: caner: CONS TION LENDING AGENCY " I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/30/07 Owner: THROCKMORTON BRUCE H Contractor: r2S6 MCD CONSTRUCTION 49881.29 PALMS HI 0 2001MORONGO VALLEY,. C(760)363-7740:Qt lwIL' N 820821G` notw WORKER'S COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ` Code, for the performance of the work for which this permit is issued. My workers', compensation insurance carrier and policy number are: Carrier STATE• FUND Policy Number 0442271205 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700;ofhe L r Code, I 1 orthwith comply with those provisions. ate: /licant: —77 WARNING: FAILURE TO SECURE WORKE OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE.COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission. related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property ff /%pfya /ty0n purposes. . _ A tr. : .. .7. _: .. iaA'1n r . 1Annliram nr_Anantl _. /! :✓// `/L•. LQPERMIT. .. Application Number 07-00000308 Permit .' . . WALL/FENCE PERMIT Additional desc . ` Permit Fee 207.00 Plan Check Fee.. .00 Issue Date . . . . Valuation . . . . 20000 Expiration Date .. 7/29/07 Qty Unit Charge Per Extension - BASE FEE 45.00' 18.00. 9.0000 THOU BLDG 2,001-25,000 162.00 ------- ------------- ---------------------- Special Notes.and Comments APPROXIMATELY 800 L.F. 6' PERIMETER WALL AT NORTH & WEST SECTIONS, ORCO SYSTEM, PER P/W & C/D APPROVALS. ".THE POLO ESTATES", TRACT 31852. Fee summary Charged Paid -Credited Due -- ----- ---- ---------- ---------- ---------- Permit Fee Total 207.00 .00 .00 207.00 Plan Check Total .00 .00 .00' .00 Grande Total 207.00 .00 .00 207.00 LQPERMIT. .. Bin # Permit V - Project Address: A. P. Number: Contractor:•• Address: City, ST, Zip: Telephone: State Lie. # Arch.,nE gr., Designer: Address: City, ST, Zip: Telephone: State Lie. #: Name -of Contact Person: Telephone # of Contact Person: # Submittal Rey+ Plall Sets Structural Cala. Truss Cales. Energy Cala. Flood plain plan Grading, plan Subcodtactor List . Grant Deed kO.A. Approval IN Ii[OUSE:- Planning Approval Pub. Wks. Appr School Fees City Of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, 'CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name: Address: City, ST, Zip: Telephone: Elm Project Descriotion:__,r -'t_ 1, . I Total Permit Fees Construction Type: Occupancy,: Project hype (circle one): New Add'n Alta Repair Demo Sq. Ft.: # Stories: 1.4 Units: Z -2-110 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE Reed TRACKING . PERMIT FEES Plan Check submitted item Amount Reviewed, ready for corrections Plan Check Deposit Called Contact Person Plan Check Balance Plans Picked up Construction . Plans resubmitted Mechanical 2" Review, ready for corrections/imue Electrical Called Contact Person Plumbing . Plans picked up S.M.I. Plans resubmitted Grading' Review, ready for.corrections/Issue Developer Impact Fee Called Contact Person A.LP.P.' .Date of permit issue Total Permit Fees GITY,.OF LA QUINTA _ PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & 'effective 11 /17/2006 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please 'DO NOT submit the Green Sheet (Public Works Clearance) .Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: j"L-Q . Developer: I Tract lo.:.3iys2 T ct Name: Palo - }P Lot No. (s): Address(s).: The following are the requirements* for Public Works Clearance to authorize issuance of a building permit, from tl;e Building & Safety Department: ❖ ;CUSTOM HOMES: PROVIDE ITEMS #2. #3. #4 AND #5 BELOW ,WALLS: PROVIDE ITEMS #7 BELOW ..;.❖ ;'SIGNS:. PROVIDE ITEMS #8 BEL - - t Aig:r- 1. Attach Pad Elevation Certificates in compliance with the approved design 'elevation for, building pad (maximum allowable deviation of .+/- 0.1 foot). Pad Elevation Certificates must be current i(within 6 months of current date). If a precise grading plan creates the pad for approval, please. withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. kAttach geotechnical certification of grading plan compliance. 3. Attach recorded final map showing proposed building locations are legal lots. 4. IIAttach a completed < 1 acre per lot or infill project Fugitive Dust Control project information .form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan.. PM10 plans for commercial & residential developments (beyond 1 lot). dare. submitted separately with grading plans & are subject to additional requirements. 5. Attach an approved precise grading plan for the building location(s). AO flood zone developments :Will require an approved flood plain development plan. 6. iAttac for the building location(s): ttach wall plan & related:approved grading p8. ?Attach sign layout/plan te precise gra ing/landscape plan. have {'reviewed and confirmed the requirements listed ab ve as presented and find the improvements to be sufficiently complete for construction of th propo buildings/structures/walls/signs on the subject lot(s). Pursuant to findings, t e pro' ct m e released for building pe it issuance. Recommended by: Dated: ' O 'Works Works Distribution: ( Green Sheet to Building & Safety counter {_) Green.Sheet.to Community Development DeclinE-d for approval for reason(s) as follow(s), please correct and resubmit: Ixcoot.m . ^ MEMORANDUM f0: Public Works Department =ROM: Wally Nesbit, Principal Planner " )ATE: 1112/2007 3E: TT 31852 — PERIMETER WALL PERMIT CHECK Fhe developer has requested issuance of a perimeter .wall permit. The below Fisted tems need to be addressed. I . Wall. permit may. only be issued for the north and west perimeter wall sections; and interior retention basin walls, as highlighted on the attached. . rough grading plan submitted. ?. This. submittal is a copy of the RG plan; it is not a perimeter wall plan. Per note on sheet 2, submit wall design with landscape plans for project perimeter along Madison and Avenue 52. No review or approval has been granted for. landscaping and wall designs in .the perimeter landscaped areas. 3. Block walls along Madison and. Avenue 52 shall be decorative, and be stuccoed and capped at a minimum. Wall design shall consider that Avenue 52 is an image corridor designation in the 'La Quinta General Plan: Wall location should be staggered/meander, and be sensitive to the multi-purpose trail layout. f you have any questions, please contact me at X7069. Assistant Plannar Perirriwall LANDSCAPE: LOIS: v.yz Ht,RG GROSS ACREAGE. 8.47 ACRES EXISTING LAND USE: VACANT PROPOSED LAND USE. RESIDENTIAL RVL ALLOWABLE' MINIMUM LOT SIZE. 20,000 S.F. AVERAGE LOT SIZE. 20,482 S. F. MAXIMUM LOT SIZE. 21,996 S.F. MINIMUM LOT SIZE. 20,002 S.F. FLOOD ZONE (FEMA) ZONE: X COMMUNITY PANEL NO. 060709 0001-0010 MAP REVISFO: AUGUST 19, 1991 A FINAL DI?AINAGE STUDY WILL BE SUBMITTED PRIOR TO RECORDATION OF THE FINAL MAP. LEGEND P. E. PROPOSED PAD ELEVATION 3.294 PROPOSED STREET GRADE AND DIRECTION OF FLOW 111 —_ EXISTING CONTOURS RETAINING WALL T.E. INDICATES TRASH ENCLOSURE D.E. INDICATES DRAINAGE EASEMENT L.P. INDICATES LOW POINT O.E. INDICATES BOTTOM ELEVATION W.S. INDICATES WATER SURFACE LEGAI'_ DESCRIPTION AM _7M- T.P. Jtt . + 01 cn ~ Z T.6S. ` TRAIL AVE 51 R.7E. z 0 > tMm I-' AVENUE 52 j MCUMT srrE .50.80 .514.,2 VICINITY MAP THOMAS GUIDE COORDINATES PAGE 5470, C-7 NO SCALE ~---- ` P.L. INDICATES PROPERTY LINE G. INDICATES GUTTER ELEVATION F.L. INDICATES FLOW UNE F.G. INDICATES FINISHED GROUND F.S. INDICATES FINISH SURFACE ELEVATION T.P. INDICATES TOP OF PAVEMENT ELEVATION T.C. INDICATES TOP OF CURB ELEVATION T.G. INDICATES TOP OF GRATE ELEVATION N.P. INDICATES HIGH POINT G.B. INDICATES GRADE BREAK T.W. INDICATES TOP OF WALL T.R.W. INDICATES TOP OF RETAINING WALL T.F. INDICATES TOP OF FOOTING IN THE C17Y OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, BEING ALL OF LOT 2 OF TRACT 6682 AS FILED 1N MAP BOOK 88, PAGES 42-43, OFFICIAL RECORDS, AND SITUATED IN THE SOUTHEAST 1/4 OF SECTION 4, T. 6 S., R. 7 E., S.B.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS., BEGINNING AT THE SOUTHWEST END OF A CUTBACK UNE AT THE INTERSECTION OF THE WESTERLY RIGHT—OF—WAY UNE OF MADISON STREET WITH THE NORTHERLY RIGHT—OF—WAY LINE OF AVENUE 52; THENCE, ALONG THE SOUTHERLY LINE OF SAID LOT 2 AND THE NORTHERLY RIGHT—OF--WAY UNE OF SAID AVENUE 52, SOUTH 89' 45' 43" WEST, A DISTANCE OF 592.67 FEET TO THE SOUTHEAST CORNER OF LOT 12 OF TRACT 21176 AS FILED IN MAP BOOK 166„ PAGES 95-97, AND THE SOUTHWEST CORNER OF SAID LOT 2; THENCE, ALONG THE EASTERLY UNE OF LOTS 12, 13 AND 14 OF SAID TRACT 21176, AND THE INESTERLY UNE OF SAID LOT 2, NORTH 00' 10' 23" EAST, A DISTANCE OF 599.61 FEET TO THE SOUTHWEST CORNER OF LOT 3 OF SAID TRACT 6682 AND THE NORTHWEST CORNER OF SAID LOT 2; THENCE, ALONG THE SOUTHERLY LINE OF SAID LOT 3 AND THE NORTHERLY UNE OF SATO LOT 2, NORTH 89' 45' 33" EAST, A DISTANCE OF 615.51 FEET TO THE SOUTHEAST CORNER OF SAID LOT 3, THE NORTHEAST CORNER OF SAID LOT 2, AND IN THE WESTERLY RIGHT—OF--WAY UNE OF SAID MADISON STREET; THENCE, ALONG THE EASTERLY LINE OF SAID LOT 2 AND THE WESTERLY RIGHT—OF—WAY UNE OF SAID MADISON STREET, SOUTH 00' 10' 23" WEST, A DISTANCE OF 576.80 FEET TO THE NORTHEAST END OF AFOREMENTIONED CUTBACK LINE; THENCE, ALONG SAID CUTBACK UNE, SOUTH 44' 58' 04" WEST, A DISTANCE OF 32.41 FEET TO THE POINT OF BEGINNING AND CONTAINING 8.47 ACRES. OWNED BLAKE JUMPER RINDLESBACH CONSTRUCTION 80-553 JASPER PARK INDIO, CA 92201 TEL, 801.560.3905 Approved b . Reso # 0 Planning Commission ------ City Council ,Comm ity Deu Dept.------ nitials ----- ---- Case No. ZT__3 2 --- Exhibit ❑ 1Nith Conditions —. _--- ,,f'uv Az r','v0S/. / v vca2 f}7 /v✓l.s i fiin r.✓a-ic s Cc* S cy✓ty tt ss SOIL ENGINEER SLADDEN ENGINEERING 39-725 GARANO LANE, STE. G PALM DESERT, CA 92211 (760)772.-3893 i THE UNDERSIGNED SOIL ENGINEER AND FOUND IT TO BE IN SUBSTAI CONTAINED IN HIS SOILS REPORT REPORT NO. 544-4141/04-04-1 PROVIDE SOIL E NGNI EERING SER%4 FOUNDATION PHASES OF THE WOf SPECIFICATIONS AND RECOAIMENW THAT SUB -SURFACE CONDITIONS 1 CONSTRUCTION. THE SOIL ENGINE DIRECTION OF THE ACTUAL WORK CONTRACTOR FOR THIS PROJECT ALSO BE INFORMED THAT NE/THE1 oXCUSE i T 1N THE OBSER OR 0 BRETT L. ANDERSON OVEREXCAVATIC OVEREXCAVATION AND RECOM SHOULD BE PERFORMED TO 2 FEET BELOW BOTTOM OF OVEREXCAVATION SHOULD BE CONDITIONED AND RECOMPAC OVEREXCAVATION AND RECO& PAVEMENT AREAS SHOULD B GRADE OR FINISH GRADE, Wi NOTE: THE OVEREXCAVATION LIMITS FINAL OVEREXCAVATION LIMIT COMMENCING ROUGH GRADIN LEGEND LIMITS OF BUILDING OVEREXCAVATION (3') UTILITY PURVEYORS WATER/SEWER COACHELLA VALLEY V P.O. BOX 1058 COACHELLA, CA 92: (760) 398-2651 ELECTRIC IMPERIAL IRRIGATION 81-600 AVENUE 58 P.O. BOX 1080 LA QUINTA, CA 9225 (760) 398-5825 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT _ Form updated & effective 11/17/2006 Ureen'Sheet approvals are forwarded to the Building & Safety Department directly r b Public Works. Please(DO NOT submit the Green Sheet (Public. Works Clearance) Packet to the Public Works. Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 91— Il -0 Developer: Tract 1o.:_3 g]SL2__ TrVct Name: P,,i Lot No'. (s): — Address(s): a a. IM,btn The following are the requirements for Public Works Clearance to authorize issuance of a building permit from tfie Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4 AND #5 BELOW s• ~TRACT HOMES PROVIDE ITEMS #1 #2 #3 #4 (AS APPLICABLE) AND'#6 BELOW •:;, ►COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 + #3 AND #5 BELOW iC I WALLS: PROVIDE ITEMS #7 BELOWQ ❖ :SIGNS:. PROVIDE ITEMS #8 BELOW ( S '° r cN 1. 4ttach Pad Elevation Certificates in compliance with the a P approved design elevation for building pad (maximum allowable deviation of .+/- 0.1 foot). Pad Elevation Certificates must be current "Within 6 months of current date). If a precise grading plan creates the pad for approval, please. withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance. 3. attach recorded final map showing proposed building locations are legal lots. 4. o,%,ttach a completed < 1. acre per lot or infill project Fugitive Dust Control project information.form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference rhumber or hard copy plan. PM 10 plans for. commercial &'residential developments .(beyond 1 lot) Lire submitted separately with grading plans & are subject to additional requirements. , 5. Attach an approved precise grading plan for the building location(s). AO flood zone developments evill require an approved flood plain development plan. 6. ttac for the building location(s). T_ \ttach wall plan. & related approved grading p 8. Attach sign layout/plan re ate precise gra ing/landscape plan. I have rr viewed and confirmed the requirements listed ab ve as presented and find the improvements tb be sufficiently complete for construction of thpropo buildings/structures/walls/signs on. the subject lot(s). Pursuant to findings, t epro' ct m e released for 'building pe mit issuance. Recom ended b f + : y Dated:_ O D Public "forks Distribution: (_ Green Sheet to Building & Safety counter ( 1 Gm reen.Sheet to Community Developent Declined for approval for reason(s) as follow(s), please correct and resubmit:' III u , 01 4 C . OF Tt ° MEMORANDUM TO.: Public Works Department FROM: Wally Nesbit, Principal Planner DATE: 8/10/2006 'RE: TT 31852 — ROUGH GRADE MYLAR CHECK Review of final mylars for the above reveals the following minor. corrections to be necessary. These are noted on the mylars as well. 1'. Sheet 2 - A 10' wide .multi-use trail is required along entire Madison Street frontage The section north of the entry to the tract calls out an 8' meandering sidewalk. I 2. All wall plans will. require review by CDD.. No I review or approval has been granted for landscaping and wall designs in the perimeter landscaped areas, and approval of rough grading does not imply approval of.final wall locations or design as. shown. Please include the note as added by staff at Sheet 2 3. Sheets 1 and 2 show a change in sidewalk. surfacing at the secondary (emergency) access on Avenue 52. Please verify and call out surfaces. If you have any questions; please contact me at X7069. c: Assistant Planner LIST OF INSPECTIONS SEQ ID SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS 2/7/2007 2/7/2007 WALL/FENCE - SETBACKS Unassigned APPROVED Notes: 2/7/2007 2/7/2007 WALL/FENCE - FOOTINGS Unassigned APPROVED Notes: 2/9/2011 2/9/2011 WALL/FENCE - FINAL Unassigned APPROVED Notes: Permit Number: BLCK-07-308 Site Address: 51911 MADISON ST City, State Zip Code: LA QUINTA, CA 92253 Applied: 1/30/2007 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: THROCKMORTON BRUCE H Contractor: MCD CONSTRUCTION Description: Finaled: 2/9/2011 Status: FINALED Details: APPROXIMATELY 800 L.F. 6' PERIMETER WALL AT NORTH & WEST SECTIONS, ORCO SYSTEM, PER P/W & C/D APPROVALS. "THE POLO ESTATES", TRACT 31852. [HTE Entry: 1/30/2007] Printed: Friday, 13 August, 2021 1 of 1 Permit Inspections City of La Quinta