Loading...
PLBG (08-1211) + SFD (9792)51880 Avenida Madero 08-1211 9792 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00001211 _ Property Address: 51880 AVENIDA MADERO APN: 773-154-007-18 -000000- Application description: PLUMBING Property Zoning: COVE RESIDENTIAL Application valuation: 4500 Applicant: Architect or Engineer: 10 ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business a d Professionals Code, and my License is in full force and, effect. License Class: C21 C42 Li ense No.: 48218 Date1, I11d . Contractor: td. r OWNER-BUILDE ECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are -not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the workfor which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/17/08 Owner: BOB VADEN 7360 BIRCH BAY DRIVE BLAINE, WA 98230 (360)371-3875 // Contractor: ALMS UNDERGRO D ON_00e,I IL . 0 38703 VISTA IV v CATHEDRAL CIT CAC 4 Lic. No4: 482180 lea 4e --------------- - - - - ------ - - - - -- ------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the fallowing declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier CALIFORNIA INS Policy Number 460093580104 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if Iould become subject to the workers' com ensation provisions of Section Y00000f the Labor I shall fort th co m ly with t s ovisions. Date.✓ 7 U QOAPPIicant: WARNING: AILURE TO SECURE WORKERS OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Ariy permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I certify that I have read this application and state that the aboveinformation is correct. I agree to comply with all city and county ordinances and state laws relating to buil i truc constion, and hereby authorize resentatives of this county to enter upon the above-mentioned propert inspection p ses. Date:nature (Applicant or Agent): a"O Application Number . . . . . 08-00001211 Permit PLUMBING SEWER Additional desc . Permit Fee 30.00 Plan Check Fee 00 Issue Date Valuation . . . . 4500 Expiration Date . . 1/13/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SEPTIC ABANDONMENT / SEWER HOOK UP Fee summary Charged Paid ----------------- Credited Due -------------------- Permit Fee Total 30.00 ---------- .00 ---------- .00 30.00 Plan Check Total .00 .00 .00 .00 Grand Total 30.00 .°00 .00 30.00 LQPERMIT COACHELLA VALLEY WATER DISTRICT CASH RECEIPT DETAIL I _ 1 _ Received From: r" `i " • ° "' " Address: ► / 7 ) r l ` _ Account No. Lt)t(s) Service Address - `Z , j fJv V ` VVI rt, -14 -If ❑ Meter(s) ❑ Service(s) ❑ Backflow(s) ❑ House Lateral(s) ❑ Detector Check(s) ❑ Meter Surcharge Sanitation Capacity Charge ❑ W.S.B.F.C. ❑ S.I.W.S.C. ❑ Temporary Construction Meter ❑ Turn on Charge ❑ Uncollected Account - Name ❑ Inspection Fee - Tract - Fee - ❑ Plan Check Fees Water / Sewer - Tract - ❑ Bond Payment -A.D.- Bond Assmt ❑ Customer Deposit ❑ Other Remarks: tj -Copy to: .Yyi 1/1 Jr, Cash Check 2/DI Money Order C ` 122996 7111 1 i ract G.A. Code TOTAL / Water Service l Cashier y f+ ` CVWD•438 (1/05)—,,.,,w Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:' 7/ Qi o 4 e ; M mc/e io Owner's Name: Vadl- y\- A. P. Number: Address: % 3 9 0 12j Legal Description: City, ST, Zip: .71a i n Li/ g 3 -2.3 O Contractor: PV— b U l l e r'o L/\ —j Telephone: 390. 37/- 3 8 7 -5 Address: `3 8- ,D 3 v -dl 12)dr— Project Description: 5 2 w e r Cpy, hec- i o ► City, ST, Zip: Ci `42-7-3 V Telephone:NOW 1111i 21119, State Lic. # : 1/8 2-1 gQ City Lic. #: 76 Arch., Engr., Designer: Address: .City; ST, Zip: k Telephone: } h I State Lic. #: Name of Contact Person: Construction Type: yp Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec.'d TRACKING. PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading, plan Zed Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE: ''d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 44 P.O. BOX 1504 N Q. 9792 Building 78-105 CALLE ESTADO / r Address 51880 Madero LA QUINTA. CALIFORNIA 92253 /J Owner Roger Snellentierger BUILDING: TYPE CONST. OCC. GRP. Mailing Address 54360 14artinez A.P. Number City Zip Tel. La Quinta. 92253 1564-0793 Legal Description Lot 18 Block 31 Contractor Expectation COPlS ruction Project Description Address SFD same City Zip Tela State Lic. City & Classif. B 613406 Lic. # 858 Sq. Ft. 155? No. No. Dw. Arch., Engr., Size Stories Units Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and m (cense is in full force and effect. r ,-—'%1t-t.if'-✓ a -t . SIGNATURE'r 1S .I DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following 95,619.50 reason•.'(Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also AMOUNT requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. :no . nq subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. 278.88 do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. 'l Sfl Professions Code: The Contractor's License Law does not apply to an owner of property who • builds or Improves thereon and who does such work himself or through his own employees, Mech. 49 . 00 provided that such improvements are not intended or offered for sale. If, however, the budding or improvement is sold within one year of completion, the owner -builder will have the burden Electrical 12$ 5 of proving that he did not build or Improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing 50struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for S.M.I. 9. 60 such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)4 Grading 2-0. 00 ❑ I am exempt under Sec. B. & P.C. for this reason Driveway Enc. 20.00 Date Owner Infrastructure 2020.34 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. TOTAL 3558.32 3308.32 CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws ofCalu0nia Date Owner NOTICE TO APPLICANT., If, after making this Certificate or Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked. Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. Issued by: Date Permit I agree to comply with all city and county ordinances and state laws relating to building constructiorj; and hereby authorize representatives -of this city to enter the above.. mentioned property for inspection purposes. Validated by: Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ 2ND FL SO. FT. ® POR. SO. FT. ® GAR. SO. FT. ® CARP. SO. FT. WALL SO. FT. ® SO. FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE Not to be used as property tax valuation BONDING FLOOR DRAIN MECHANICAL FEES FORMS WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPJEOUIP. LAUNDRY TRAY AIR HANDLING UNIT CFM TEMP. POLE KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 Vi c SEWAGE DISPOSAL O� SO.FT.GAR ® 114c HOUSE SEWER REMARKS: GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING 9/e4ffQERGROUND A.C. UNIT COLL. AREA SLAB GRADE/� ROUGH PLUMB. 49 sm 09 BONDING HEATING (ROUGH) STORAGE TANK FORMS E IC IANK ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. l0 Q% �,/ GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING yd. $ plus x$ _$ LUMBER GR. FINAL INSP. 1.412P1.91cu. FRAMING �Q/� 9r FINAL INSP. ROOFING O� REMARKS: VENTILATION FIRE ZONE ROOFING: FIREPLACE SPARK ARRESTOR GAR. FIREWALL I , LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION - CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 9/16/91 No. 1 10866 Owner Name Type of Permit Roger Snellenberger No. 51880 street Madero City La Quinta zip 92253 La Quinta Permit # Log # Study Area 113 APN # , Tract # Lot # ® Square Footage 11557 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 5.3080 in the amount of 1.58 X 11.557 1 or $ 2,460.06 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By Expectations Construction Telephdne teli4.d179<3 Name on the check ,." $y James E. Lively Assistant Superintendent, Business Services Fee collected /exempted by �r Peggy Reyes Signature Check No. 0188 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting Payment Receiv'4& , � Check No. 0188 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting SENT BY: XEROX Telecopier 7017; 9-16-91 ; 16:00 ; r1coptDINv rRsouselrzo by 0 6193418296 56456174 2 r- AND wNaa teRcatebso X1416 TO MA.ra Roger AeowRrra 55-965SPebbleb8®,ch Assoc. u,rT a LA Quinta, Ca 92253 1{TAT9 L J r MAIL Tax STATebsaya Te SPACE "OVItC PHIS LINIC R01t RAC NA�a t Documentary tranefer tAx g,.,,,, 82.50 Aoo.cs. Computed on full value of Property rohveyed. or Q'fy a SAME AS ABOVE Computed on (1111 value lase (ienri 8 enr,lmhr,thceh BrAK L remaining thereon at time of ,tale. ei Signaturef o dectorent or aaeat lolermining I'll , firm Unincorporated area City of ........ name Il �y d Deed PARCEL No This fom AUT11ahed by OrWe Coast Title Company FOR A VALUABLE CONSIDERATION. receipt of which is hereby acknowledged, CO -Tru A. SOTTO SANfii, JR., Co-Trugte® e CO -Trust ee of the Sotta Banti E Dated November5 amity TId 'Trust Services of rust Under that Cartian Declaz'atio cles 1 and 3 hereby GRANT(S) n�,ofe . at to Par Trust 1381 to ROGER SNELLENSEAGER ii ASSOCIATES, is California Corporation the following described real property in the county of Riverside State of California: LEGAL DESCRIPTION IS ATTACHED AS EXHIBIT "A' Dated August 16LAWRENCE A• SOTTO SANTI, , 1991 T u JR., Co - UST SER'jICBS F AMERICA o -T u S ccessor STATS OF CA IFORNCAMA CAtiNITY OF vn sil:ned, a before nt®, the Under os■ry Pub11e In and for said County and State, personally �ppe red.—,� • —� Ire the perao'l-.whnae name .known to me WoMent and aeknowiedRedthat�� "6acribed to the with!, executed 1ht deme. StRnatur® of Alotary ame (Typed or Printed) of Notary e -Order No, MAIL TAX $TA-rFkAv.,-.. . _ vlleapl _ Extended Pa ids —�: ,7 Assistant Se retary FOR NOTARY sRAL OR STAMP WI�CY 8 HART NOTARY PUBLIC. CALIFORNIA LOa ANGELES COUNTY toy COalfrf, f orYi may It.1995 0 SENT BY: XEROX Teiecopier 7017 9-16-91 16:01 619341429p6-► N�� ;.,CAT. NO. NNO0727 � TO 9stl6 CA le -841 TICOR TITLG iN. N (Corporation) STATE OF CALIFORNIA SS COUNTY OF SAfJ l�E+ Ra2DIsv 1 $ a 1 hefore me,the undersigned, a Notary Public in and for On G 403 aced said State, personally apps personally known to me or proved to me on the b€sis 1 of satisfactory evidcrce to be the j s Lwho executed the within instrument as the President, and 12 y 16 ZZ personally known to me or graved to me on thebasis of satisfactory evident: to be Lh .9erson who executed' the within i+istrument As'the .a; 1 .� Secretary of *,e Corporation that executed the within instrument and acknowledged to me that such corporation executed the within instru- men, pursuant to its bylavis or a resolution of its board of directors. WITNESS my hand and official seal. n Signature �> {` •�¢�� .W Aw1Pcaavwswwwtw4G1a 604 OFFICIAL SEAL MARION V. ®U CASSE NOTAF0 PUSLIC— AUFORNOA ii0'PARY BOND FK= IN ANGELES COUNTY p My Cwm'%Ga bp1 mg OCWw 4. 1491 (This area for official nCtarial seal) 56456174 3 UNT BY: XEROX Telecopier 7017; 9-16-91 ; 16:02 ; , EXHZDIT "A" 6193418296-+ Lot 21 in block 32 of Santa Carmelita at Vale La Quint&, Unit 2, as shown by map on file in Book 18, page 55 of maps, records of Riverside County, California. EXHIBIT "B" 5645617;# 4 Lot 18 in block 31, o£ Santa Carmelita at vale La Quinta, Unit No. 2, as shown Pages 55 and 56 of maps, records of Riverside County, by map or. file in Book 18, California. EXHIBIT "C" Lot 17, Block 38, Santa Carmelita at vale La Quint&, Unit 3, as shown by map on file in Book 18, gage Sg of Maps,=ecords of Riverside County, California- on "D" LUnit No. 31 in the ot S in $1GCk 41, of Santa Ca-melita at Vale Ln Quirt�� an file in Book 1$, County of Riverside, State of California, as shown b} p page 58 of maps, records of Riverside County, California. =mIZIBIT nen Lot li, block 8 of Santa Carmelita at vale La Qninta, Unit No. 1, as shown by map on file in Boob: 18, page 66 0= Nlaps, records of Riverside County, California. �.. K CALVIN C. KAMINSKAS s Assistant Commissioner (714) 275-3000 6j•, L ■ OFFICE OF AGRICULTURAL COMMISSIONER JAMES O. WALLACE, Commissioner 83-612 Avenue 45 Suite 7 Indio, CA 92201 (619) 342-8291 DATE qUM ail "(99 i...- CASE NO. DEVELOPER'S NAMES ADDRESS, GA- �0/nii TELEPHONE: ( ) _5_91L/- Caf 17 .39 aikz Lo .20 & e4 st/ %A "ea. a6&41 Ma,&►o [ifs �ockis-7 ea vua tels B/o> o/ M4un td t 7 ,Q, W Udo Dear Developer: After reviewing your landscaping plans, all plant material listed is not in violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material listed, this office must be notified immediately. lbank you for protecting and preserving the Coachella Valley's pest -free environment. . P_,e&Cra_ Agricultural Comnissio is Office cce Indio and Riverside 4080 LEMON STREET. ROOM 19, RIVERSIDE, CALIFORNIA 92501 — FAX (714) 275-3012 0 , T.Z. /l. DAN RILEY Sealer. Weights & Measures, . (714) 275.3030. X- • t "S w DATE qUM ail "(99 i...- CASE NO. DEVELOPER'S NAMES ADDRESS, GA- �0/nii TELEPHONE: ( ) _5_91L/- Caf 17 .39 aikz Lo .20 & e4 st/ %A "ea. a6&41 Ma,&►o [ifs �ockis-7 ea vua tels B/o> o/ M4un td t 7 ,Q, W Udo Dear Developer: After reviewing your landscaping plans, all plant material listed is not in violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material listed, this office must be notified immediately. lbank you for protecting and preserving the Coachella Valley's pest -free environment. . P_,e&Cra_ Agricultural Comnissio is Office cce Indio and Riverside 4080 LEMON STREET. ROOM 19, RIVERSIDE, CALIFORNIA 92501 — FAX (714) 275-3012 0 a+1�. • �Y asYi�./. er. •.�•• ..f-.- � t ... .. .:. , .�•. . .. ... ......y.sH!yn+.. .. . �.�:�•�{FI.Cl11 �,r, ♦14A COUNTY OF RIVERSIDE DEPARTMENT OF HEALTH Aass..or.ParaelNor ENVIRONMENTAL SERVICES DIVISION PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Applicant: Submit this form with four copies of a scaled plot plan (1-20 scale) drawn to County speculations as Indicated on the attached ct" NIL e_flliny fee (see below) is required when the application is submitted. Check must be made payable to the County d 3zls j ,8�of this application shall remain valid for a period not to exceed one year from date of approval• r t0 QBi�I VERIFY ITEMS461 SECTION A FROM BUILDING 8 SAFETY APPLICATION BUILDING DEPARTMENT APPLICATION LOG N AA -��Ptpr+e� Address &Firm � T �5% 1 Owner Phone Making Address CO City slate Zip Job rty A4d Llegal D'escription • (PM, Tlect, Lot) Lot Size 6ftter _ A 11 Use of Fbrmk P/P, CU, etc.v /1,,1.,_A Other // [ / /1 L _ 19-1 /! _ 4 REV CODE FEE 1238 1238 $ 57.00 Signature of Apt $ 24.00 7344 CATEGORY: 7348 $111.00 SUBSURFACE DISPOSAL to O MULTIPLE PARCELS WITHIN SAME SITE EVALUATION UPON REOUEST 7340. LAND DIVISION Z 0 (NO PLOT PLAN) a. 1 at 4 Parcels (Each) 17) O b. Each Parcel after 4 7348 ' O Rereview (2nd review same parcel) U) O Site Evaluation In Conjunction with ❑ PRELIMINARY ELECTIVE Critical Area $ 23.00 '$ O Site Evaluation Lot Lees than 10,000 Sq. Ft REV CODE FEE 1238 1238 $ 57.00 7344 $ 24.00 7344 $ 24.00 7348 $111.00 7347 $ 87.00 Hddkq Tank Agreements Completed Coacatlon of Existing S.D. System Required ' WOCB Clearance required. (Attach Form DOH SAN 007, Santa Ana Region Only) Soils Peroolatim Report Required. Special Feasibility Boring Report Required. DoWed Contour Plot Plana Required (1 to 5 R Interval) Other Still Specialist Lot Inspection Required /N�� ATE ❑ Yes ��// '"'�'�'� 21 O Yes Q'Ne ❑ Yes O Yes ❑ Yes O Yes ❑ Yes O Yes Zo - Lot 11 Date So% boring report by Prow * Date so% Map Pape Sao Type Approved by � Date N0. of Systeme Typed Symorn(s) Na Dwelling Unita r (1) Septic Tank Sok Rab Greeae/serrd O ypldinp Tiink O Exlalkrp Bedrooms, IMrr06"W'" kftp .. j�f4ew o Replacement 1.2. 3 ft _it wAh Bad as ft .�, ��.� � '� F Date SldewaA albwetros R rock/_eq• R per riming It. � �• -� CATEGORY: REV'CODE FEE Leechiftmoed special design for elope: (3) Pk Diameter 4OW 1*16 plc. Pis PM Below InkO (81) I SITE EVALUATION UPON REOUEST 7340. $ 43.00 (NO PLOT PLAN) } O SEWER/SEPTIC VERIFICATION 7348 ' $ 17.00 (Less than 1 year) 'f ❑ PRELIMINARY ELECTIVE 7352 $ 23.00 '$ EVALUATION (Attach DOH SAN 53) O HOLDING TANK 7351 $ 47.00 O ALTERNATIVE/EXPERIMENTAL 7345 $222.00 f SYSTEM x /N�� ATE ❑ Yes ��// '"'�'�'� 21 O Yes Q'Ne ❑ Yes O Yes ❑ Yes O Yes ❑ Yes O Yes Zo - Lot 11 Date So% boring report by Prow * Date so% Map Pape Sao Type Approved by � Date N0. of Systeme Typed Symorn(s) Na Dwelling Unita r (1) Septic Tank Sok Rab Greeae/serrd O ypldinp Tiink O Exlalkrp Bedrooms, IMrr06"W'" kftp .. j�f4ew o Replacement 1.2. 3 ft _it wAh Bad as ft .�, ��.� � '� F Leech Uro Sq. Ft trench area SldewaA albwetros R rock/_eq• R per riming It. � �• Ineid LMne(e) bn0 drAo. c balaw drekrlires or ` . 4 • " a Leechiftmoed special design for elope: (3) Pk Diameter 4OW 1*16 plc. Pis PM Below InkO (81) I (rD) Seepage PM ToblPeplh Max. AlDepth WA Overburden factor - No, 2 System Al n 1/ REMARKS:` 0 Z O 13 This eppliostion Is PROVED III:Br for the category checked In SECTIPN •B above, regarding the d"n of a subsurface disposal system as Ind' NJ N on the scoompan p o pan, using the requirements set forth in SECTION C a permit 'is necessary for the installation of the . abovs-deeigned system. i pansign• a 1) Septic tank and sewer Imes must be 50' minimum from any welb,QliO� Leach lines must be 100' minimum from any wells, including expansion rea. , e 1 dre�y • . CALCULATIONS FOR: Standard 66.82 Jim Snellenberger Expectation's Construction 54-360 Avenida Martinez La Quinta, CA PROJECT: EXPECTATIONS PLAN 1557 East La Quinta. CA Proposed 65.05 Compliance +1.77 Wall R-19 (R-11 plus 1 in foamboard), Roof R-38, Duct R6, Dual glazing, V. Blinds, 40 gal electric water heater With Recovery, SEER 10.0, HSPF 6.6 1 original each CF -IR MF -1R C -2R C -3R DHW HVAC Sizing Manufacturer's specifications for Suggested HVAC equipment. ACTUAL SELECTION OF MECHANICAL EQUIPMENT IS RESPONSIBILITY OF OWNER OR CONTRACTOR. =----------------------------------------------------------- 79-733 Country Club Dr., Bermuda Dunes, California 92201 (619) 360-0535 (714) 763-4250 La Yu r n t -a , 1rH Documentation Author... C. Randall -Christensen Building Permit # .,'Company ................ T-24 Energy Calcs Co. -- Telephone .............. (619) 360-0535 Plan Check / Date ----------------- Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone..... 15 --------------------- ----------- MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.3.8.6ele ---------------------- -------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 1557 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION ------------------------- Component Insul Type R -value Location/Comments Wall R-19 front, Front.kit, Corner, left, back right Wall R-11 to garage Roof R-38 attic Door R-0 solid wood, to garage S1abEdge R-0 to outside, to garage GLAZING Glazing Area # of Interior Exterior Framing Orientation ------------------- (sf) ------ Panes ----- Shading ---------- Shading -------------- Overhang Type Window Front (E) 40.0 2 Drapes. None -------- Yes -------- Metal Window Front (E) 30.0 2 Blinds 50o bug scrn Yes Metal Window Right (NE) 10.0 2 Blinds 50o bug scrn Yes Metal Window -. Right (NE) 2.0 2 Drapes None Yes Metal Window Front (SE) 10.0 2 Blinds 50% bug scrn Yes Metal Window Front (SE) 2.0 2 Drapes None Yes Metal Window Left (S) 64.0 2 Blinds 50% bug scrn Yes Metal Door Right (N) 80.0 2 Blinds 50% bug scrn Yes Metal Window Right (N) 6.0 2 Blinds 50% bug scrn Yes Metal Window Right (N) 12.0 2 Blinds 50% bug scrn None Metal Skylight Right (N) 4.0 2 none Tint None Metal . .+ I — -1 1 v i I _. i c_ a 1=1 �jy Va 1ub �.,u . MUrl-UVOMro OAt, `. n I �J . iu . be le ------------------------------------------------------------------------------- THERMAL MASS Area Thickness Hard Surfaced/ Type (sf) (in) Exposed Location/Comments ------------ ----------------------------- ------------------------ S1abOnGrade 128 3.5 Yes kit.baths S1abOnGrade 1428 3.5 No typical ASSUMED HVAC SYSTEMS Assumed Duct Duct Assumed System Efficiency --------------------------- Location R-value HeatPump 6.6 HSPF ------------- Attic ------- R-6 AirCond 9.50 SEER Attic R-6 ACTUAL HVAC SYSTEMS CEC Maximum output for Gas Central Furnaces: _ Btuh -------------- WATER HEATING SYSTEMS Tank R-12 or # of Vol Greater Manufacturer and Model # Energy System Type Heat (gal) Blanket (or approved equal) Credits --------------- ---- ----- ------- ---------------------------- ---------- Storage, Electric 1 40 Yes A.O.SMITH PECO52 Recovery SPECIAL FEATURES/REMARKS Square footage used in these calculations includes the walk-in closet in Master Bedroom but no other closets. Specified HVAC equipment is used only as an example to assist client in demonstrating Title -24 compliance. ACTUAL SELECTION OF EQUAL TO OR BETTER EQUIPMENT IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SPECIFICATIONS FOR FINAL EQUIPMENT SHOULD BE SUBMITTED TO BUILDING DEPARTMENT FOR PLAN CHECK., Actual Output Manufacturer and Model # Actual System --------------- Efficiency ----------- (Btuh) -------- (or approved equal) Heating 7.5 40000 --------------------------------- LENNOX C818-51 Cooling 10.3 40000 LENNOX HP20-461 Cooling Coil CEC Maximum output for Gas Central Furnaces: _ Btuh -------------- WATER HEATING SYSTEMS Tank R-12 or # of Vol Greater Manufacturer and Model # Energy System Type Heat (gal) Blanket (or approved equal) Credits --------------- ---- ----- ------- ---------------------------- ---------- Storage, Electric 1 40 Yes A.O.SMITH PECO52 Recovery SPECIAL FEATURES/REMARKS Square footage used in these calculations includes the walk-in closet in Master Bedroom but no other closets. Specified HVAC equipment is used only as an example to assist client in demonstrating Title -24 compliance. ACTUAL SELECTION OF EQUAL TO OR BETTER EQUIPMENT IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SPECIFICATIONS FOR FINAL EQUIPMENT SHOULD BE SUBMITTED TO BUILDING DEPARTMENT FOR PLAN CHECK., • 1V NVrJ VO. 1 1 r I IH Cllr Mk Zt.t wLn—I..IL Ib Hrogram-FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ---s--------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specificationso needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... Rob's Consultant Company. ------------------ Address. 54-085 AvenidaRamirez La Quinta, CA Phone... 9619) 564-3683 License. ------------------------- Signed - ----------------- --(date) -- DOCUMENTATION AUTHOR Name.... C. Randall -Christensen Company. T-24 Energy Calcs Co. Address. 79-733 Country Club Dr. Bermuda Dunes, CA 92201 Phone... (619)'360-0535 OWNER Name.... Jim Snellen-berger Company. Snellenberger & Assoc. Address. 54360 Avenida Martinez La Quinta, CA Phone.... (619) 564-0793 Signed ---------------- ----(date)-- ENFORCEMENT AGENCY Name... Title... ------------------------- ------------------------- Agency.. ------------------------- ------------------------- Phone.. ------------------------- 12 Signed'I -' - _ - ------ Signed ---------- (date) ----------(date)-- MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 Project Address........ Lot 3 Blk 157 Ave Rameriz --------------------- La Quinta, CA Documentation Author... C. Randall -Christensen Building Permit # Company ................ T-24 Energy Calcs Co. ----------------- Telephone .............. (619) 360-0535 Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 --------------------- ---------------------------------------- MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM MF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory .measur.es whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. * 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 2-5311: Insulation specified or installed meets CEC quality standards. Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program-FORM'MF-1R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES --------------------------------- Design- Enforce- er ment 2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * 2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 2-5352(1): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated to R-3 or greater). _____ 2-5312(Exception I): Pipe insulation on steam and steam condensate return and recirculating piping. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. LIGHTING AND APPLIANCE MEASURES ------------------------------- Design- Enforce- er ment 2-5352(j): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 Project Address........ Lot 3 Blk 157 Ave Rameriz --------------------- La Quinta, CA ----------------- Documentation Author... C. Randall -Christensen Building Permit # Company.................T-24 Energy Calcs Co. ----------------- Telephone ............... (619) 360-0535 Plan Check / Date ----------------- Compliance Method...... MICROPAS3 by Enercomp, Inc. I Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ---------------- -------------------------------------------------------------- MICROPAS3 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance o= _ (kBtu/sf-yr) _--------------------------------- Design Design ---------- Margin _ ---------- _ = Space Heating.......... 6.96 4.54 2.42 = = Space Cooling.......... 47.85 42.88 4.97 = - Water Heating 12.01 17.63 -5.62 = = Total 66.82 65.05 1.77 = _ *** Building complies with Computer Performance Zone Type HOUSE Residence GENERAL INFORMATION ------------------- Conditioned Floor Area..... 1557 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... Slab On Grade (Package D) 1 14013 cf 1556 sf 1556 sf 16.7 % of FA 9 ft BUILDING ZONE.INFORMATION ------------------------- Floor # of Vent Special Cond- Area Volume Dwell Thermostat Height Vent Area itioned (sf) (cf) Units Type (ft) (sf) Yes 1557 14013 1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/9.1 MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6e1e ------------------------------------------=------------------------------------ OPAQUE SURFACES GLAZING SURFACES ---------------- Area U- Insul Act Solar Location/ Form 3 Surface ------------ (sf) ------ value ----- R-val ----- Azmth ----- Tilt ---- Gains Comments Reference HOUSE Glass Shade GIs+ Surface ----------- ----- ---------------- ------------- 1 Wall 38 0.056 R-19 90 90 No front WR11.PWRWL 2 Wall 20 0.056 R-19 90 90 Yes Front.kit WR11.PWRWL 3 Wall 16 0.056 R-19 45 90 Yes Corner WR11.PWRWL 4 Wall 16 0.056 R-19 135 90 Yes Corner WR11.PWRWL 5 Wall 352 0.056 R-19 180 90 Yes left WR11.PWRWL 6 Wall 264 0.056 R-19 270 90 Yes back WR11.PWRWL 7 Wall 56 0.056 R-19 0 90 No.. right WR11.PWRWL 8 Wall 270 0.056 R-19 0 90 Yes right WR11.PWRWL 9 Wall 95 0.098 R-11 90 90 No to garage None' 10 Roof 32 0.029 R-38 90 23 Yes attic None 11 Roof 822 0.029 R-38 180 23 Yes attic None 12 Roof 818 0.029 R-38 0 23 Yes attic* None 13 Roof 11 0.029 R-38 45 23 Yes attic None 14 Roof 11 0.029 R-38 135 23 Yes attic None 15 Door 20 0.330 R-0 90 90 Yes solid wood None 16 Door 17 0.330 R-0 90 90 No to garage None Blinds 0.29 13 Window 12.0 PERIMETER LOSSES Metal Slider 0.65 0 90 0.77 Length 0.29 ---------------- F2 Insul 4.0 2 Metal Slider 0.64 Surface ------------ (ft) ------ Factor --------------- R-val Location/Comments HOUSE ---------------------- 17 SlabEdge 160 0.720 R-0 to outside 18 SlabEdge 4 0.550 R-0 to garage 19 SlabEdge 10 0.500 R-0 to garage GLAZING SURFACES ---------------- SC Interior SC Area # of Frame Open U- Act Glass Shade GIs+ Surface ----------- (sf) ----- Panes ----- Type -------- Type value Azmth Tilt Only Type Shade HOUSE ------ ----- ----- ---- ----- ---------- ----- 1 Window 12.0 2 Metal Slider 0.65 90 90 0.77 Drapes 0.66 2 Window 14.0 2 Metal Slider 0.65 90 90 0.77 Drapes 0.66 3 Window 30.0 2 Metal Slider 0.65 90 90 0.77 Blinds 0.29 4 Window 14.0 2 Metal Slider 0.65 90 90 0.77 Drapes 0.66 5 Window 10.0 2 Metal Slider 0.65 45 90 0.77 Blinds 0.29 6 Window 2.0 2 Metal Slider 0.65 45 90 0.77 Drapes 0.66 7 Window 10.0 2 Metal Slider 0.65 135 90 0.77 Blinds 0.29 8 Window 2.0 2 Metal Slider 0.65 135 90 0.77 Drapes 0.66 9 Window 24.0 2 Metal Slider 0.65 180 90 0.77 Blinds 0.29 10 Window 40.0 2 Metal Slider 0.65 180 90 0.77 Blinds 0.29 11 Door 80.0 2 Metal Slider 0.65 0 90 0.77 Blinds 0.29 12 Window 6.0 2 Metal Slider 0.65 0 90 0.77 Blinds 0.29 13 Window 12.0 2 Metal Slider 0.65 0 90 0.77 Blinds 0.29 14 Skylight 4.0 2 Metal Slider 0.64 0 23 0.77 none 0.77 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 -------------------- MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM C -2R User##-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin— ---Right Fin -- Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- HOUSE Area Thick Heat Conduct- Surface Mass Type --------------- (sf) ------ (in) ----- Cap ----- ivity -------- R -value 1 Window 12.0 6.0 n/a 5.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 14.0 3.0 n/a 5.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 30.0 5.0 n/a 0.5 3.0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 14.0 3.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 10.0 5.0 n/a 0.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 2.0 1.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 10.0 5.0 n/a 0.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 2.0 1.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 24.0 4.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 40.0 4.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 80.0 6.8 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 6.0 1.0 n/a 0.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a EXTERIOR ---------------- SHADING Area Shading SC of Surface ------------ (sf) ------ Type Ext Shade HOUSE --------------- ---------- 3 Window 30.0 50% bug scrn 0.84 5 Window 10.0 50% bug scrn 0.84 7 Window 10.0 50% bug scrn 0.84 9 Window 24.0 50% bug scrn 0.84 10 Window 40.0 50% bug scrn 0.84. 11 Door 80.0 50% bug scrn 0.84 12 Window 6.0 50% bug scrn 0.84 13 Window 12.0 50% bug scrn 0.84 14 Skylight 4.0 Tint 0.25 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type --------------- (sf) ------ (in) ----- Cap ----- ivity -------- R -value Location/Comments HOUSE -------- -------------------------- 1 S1abOnGrade 128 3.5 28.0 0.98 R-0.0 kit.baths 2 S1abOnGrade 1428 3.5 28.0 0.98 R-2.0 typical COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- System Type Storage Electric HVAC SYSTEMS WATER HEATING SYSTEMS --------------------- Papa- R-12 or Pilot # of city Greater Effic- Standby Input Size Heat (gal) Blanket iency Loss Rating (Btuh) Credits 1 40 Yes 0.996 RE .95% 4 kW SPECIAL FEATURES/REMARKS n/a Recovery Square footage used in these calculations includes the walk-in closet in Master Bedroom but no other closets. Specified HVAC equipment is used only as an example to assist client in demonstrating Title -24 compliance. ACTUAL SELECTION OF EQUAL TO OR BETTER EQUIPMENT IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SPECIFICATIONS FOR FINAL EQUIPMENT SHOULD BE SUBMITTED TO BUILDING DEPARTMENT FOR PLAN CHECK. Minimum Duct Duct Duct System Type ---------------- Efficiency ------------ Location ------------- R -value ------- Efficiency ---------- HOUSE Heat Pump 6.6 HSPF Attic R-6 0.837 AirCond 9.50 SEER Attic R-6 0.827 WATER HEATING SYSTEMS --------------------- Papa- R-12 or Pilot # of city Greater Effic- Standby Input Size Heat (gal) Blanket iency Loss Rating (Btuh) Credits 1 40 Yes 0.996 RE .95% 4 kW SPECIAL FEATURES/REMARKS n/a Recovery Square footage used in these calculations includes the walk-in closet in Master Bedroom but no other closets. Specified HVAC equipment is used only as an example to assist client in demonstrating Title -24 compliance. ACTUAL SELECTION OF EQUAL TO OR BETTER EQUIPMENT IS RESPONSIBILITY OF DESIGNER OR CONTRACTOR. SPECIFICATIONS FOR FINAL EQUIPMENT SHOULD BE SUBMITTED TO BUILDING DEPARTMENT FOR PLAN CHECK. CONSTRUCTION ASSEMBLY Page 1 3.R Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 ------------ MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -FORM 3R User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6e1e ------------------------------------------------------------------------------- Reference Name . WR11.PWRWL Description .... R11 batt+1in isocyan Type ........... Wall R -Value ........ 19 sf-F/Btuh Framing Material .... FIR.2X4 Spacing ..... 16 inches on center Fraction ..... 0.15 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------------------------------------------ U-Value: (1 / 19.68 x 0.85) + (1 / 12.14 x 0.15) = 0.056 Btuh/sf-F Material Cavity Frame Name ------------- Description ---------------------------------------- R -Value R-Value 0. FILM.EX Exterior air film: winter value --------- 0.17 --------- 0.17 1. STUCCO.0.88 0.875 in stucco 10.18 0.18 2. ISOCYAN.1.00 1.00 in polyisocyanurate insulation 7.20 7.20 3c. BATT.R11 R-11 batt insul (cavity = 3.5 in) 11.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values --------- 19.68 z --------- 12.14 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------------------------------------------ U-Value: (1 / 19.68 x 0.85) + (1 / 12.14 x 0.15) = 0.056 Btuh/sf-F 'WATER HEATING Page 1 DHW Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 Project Address........ Lot 3 Blk 157 Ave Rameriz --------------------- La Quinta, CA Documentation Author Author... C. Randall -Christensen Building Permit # Company ................ T-24 Energy Calcs Co. --------------_-- Telephone .............. (619) 360-0535 Plan Check./ Date Compliance Method...... MICROPAS3 by Enercomp, Inc. i Field Check/ Date Climate Zone........... 15 ----------- '--------- --------------------- MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -WATER HEATING User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA ----------------- 1. Water heater type....... 2. Manufacturer............ 3. Model number............ 4. Ignition device......... 5. Tank volume ............. 6. Recovery efficiency..... 7. Standby loss............ 8. Rated Input ............. 9. Number of Heaters....... 10.Insulation Jacket....... Storage, Electric A.O.SMITH PECO52 ------------------------- n/a 40 gal .996 percent x 0.01 .0095 percent/hour x 0.01 13652 Btu/hr 1 Yes B. OPERATING DATA ----------------- 1. Climate Zone............ 2. Water heating budget.... 3. Tank set temp........... 4. Water main temp......... 5..Daily hot' water load.... 6. Ambient air temp........ 7. Adj. Standby Losses....l. 8. No. dwelling units...... 9. Pump power .............. 10.Pumping energy.......... 15 18700 kBtu/yr/unit 140 F 70 F 50 gal 72.6 F, .0076 1 0 Watts (0 Watts controller) 0 Watt-hr/yr (24 hr per day) C. WATER HEATING ENERGY CREDITS ------------------------------- 1. Credit Name ............. Recovery 2. Annual savings.......... 2805 kBtu/yr/unit D. ANNUAL WATER ------------------------------ HEATING ENERGY 1. Recovery load........... 10539 kStu/yr 2. Recovery energy......... 7765 kBtu/yr 3. Standby loss energy..... 1385 k8tu/yr 4. Pumping energy.......... 0 kBtu/yr source 5. Total energy............ 27450 kBtu/yr/unit source 6. Comparison.............. -8750 k8tu/yr/unit source 7. Points .................. -11 8. Water Heating Energy Use 17.63 kBtu/yr/sf (D5 x 88) / 1557 sf HVAC SIZING Page 1 HVAC Project Title.......... EXPECTATIONS 1557 East Date........ 06/24/91 Project Address........ Lot 3 Blk 157 Ave Rameriz --------------------- ..La Quinta, CA Documentation Author Author... C. Randall -Christensen Building Permit # Company ................ T-24 Energy Calcs Co. Telephone..............9 1 6 ( ) 360-0535 Plan Check / Date � ----------------- Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone..... 15 --------------------- ------------------------------------------ MICROPAS3 v3.11 File-EXPEC2CE Wth-CTZ15 Program -HVAC SIZING User#-MP1017 User -T-24 Energy Calcs Co. Run-DVbHP6.6AC9.5R19.38.6ele ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 1557 sf Volume ..................... 14013 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ INDIO Latitude ................... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 30 F Shading Used ............... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum output applicable for gas central furnaces only Heating Cooling Description --------------------------------- (Btuh) (Btuh) Opaque Conduction and Solar...... ----------- 10265 ----------- 5001 Glazing Conduction ............... 6927 5745 Glazing Solar .................... n/a 8128 Infiltration ..................... 8263 4897 Internal Gain .................... n/a 2550 Ducts ............................ 2546 2632 Sensible Load .................... 28001 28952 Latent Load ...................... n/a 5790 Total Load ----------- 28001 ----------- 34743 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum output applicable for gas central furnaces only Page No. i DIRECTORY OF CERTIFIED STORAGE WATER HEATERS Updated =/1/90 Electric (WES) T-24 Energy Calcs Co. 79-73= Country Club Dr. , Bermuda Duties, CA 92201 HVAC Contractor is responsible for selection of equipment. This list of suggested equipment is provided as a courtesy only. Equipment Finder v1.1 User # EF0160 --------------------- Selection Criteria: Brand ............... 58 of 58 selected Volume .............. from =8.0 up to 50.0 Rated Input......... from 4.0 up to 5.0 Rc:c Stand Rated Brand Vol Eff by Input Hght Wdth R16 Model Number (gal) (X) (1/hr) A& (in) (in) ? A. O. SMITH 45.0 99.6 0.95 5 32 25 N EDLJ-50* A. 0. SMITH 47.0 99.6 0.95 5 55 21 N EES -052 A. 0. SMITH 36.0 98.0 0.93 5 60 18 N ELST-40 •. A. 0. SMITH 45.0 99.6 0.95 5 32 25 N ELJF--50* A. 0. SMITH 45.0 99.6 0.95 5 55 21 N PEC -052 BRADFORD -WH I TE ET AL 3B.0 99.4 0.67 5 36 24 N J-I-40TT***-* BRADFORD -WHITE ET AL 45.0 98.0 0.80 5 0 24 N M -I -50L***-* BRADFORD -WHITE ET AL 45.0 98.0 0.86 5 0 20 N M -,I -50S***-* BRADFOF:D-WHITE ET AL 45.0 98.0 0.91 5 0 18 N M--'.I-50T***-* CENS I BLE 47.8 99.0 0.89 5 0 0.Y CD's:* -52 -*ORS*-**` CENSIBL, 47.6 99.0 0.75 5 0 0 Y C6i*-52-*ORT*-** CENSIBLE 42.9 99.0 t.8 5 0 0 Y P*--50•-*OLS*-* * CENS.IBLE 42.9 99.0 0.83 5 0 0 Y P*--50-*OT4*-** CENSIBLE 47.0 99.0 0.89 5 0 0 Y P* -52 -*ORS*-** CONAIRE 47.0 99,1 0.95 5 55 21 N ME -52* CONAIRE 47.0 99.1 0.85 .5 55 21 N TE -52* CONAIRE 45.0 99..6 0.95 5 32 25 N %%%�%�%%/�%�� HP20 SERIES r.L.L ) 0"111 HEAT PUMP OUTDOOR UNITS *18,000 to 43,500 Btuh Cooling Capacity *17,000 to 40,000 Btuh Heating Capacity *ARI Standard 210/240 and DOE Certified Retlnne Application — The HP20 series outdoor units with matching indoor units are designed for applications in apartments, hotels, motels, condominiums, new single family housing or retrofits. HP20 units have SEER's of up to 11.60 with a cooling capacity range of 18,000 to 43,500 Btuh and a COP rating of up to 3.38 with a heating capacity range of 17,000 to 40,000 Btuh. Matching blower -powered indoor units with optional supplemental elec- tric heat are available to provide selective sizing and installation versatil- ity. See ARI Ratings table. For complete data on Fuelmaster + TA ' systems and indoor units see individual bulletins indexed in this tab section. Out- door units are shipped factory assembled, piped and wired. Each unit is test operated at the factory to ensure proper operation. The installer has only to set outdoor unit in the desired location, connect refrigerant lines and make electrical connections. Approvals — Units have been tested with matching indoor units in the Lennox Research Laboratory and rated according to U.S. Department of Energy (DOE) test procedures and in accordance with ARI Standard 210/240-89. In addition, units are U.L. Listed and have been sound rated in the Lennox reverberant sound test room in accordance with ARI Stan- dard 270-84. Units and components within are bonded for grounding to meet safety standards for servicing required by U.L. and N.E.C. Copper Tube Outdoor Coil — Lennox designed and fabricated coil is constructed of precisely spaced ripple -edge aluminum fins machine fitted to seamless copper tubes. Precise coil circuiting gives uniform refrigerant distribution for high efficiency. Extra large four sided wraparound coil con- figuration provides extra large surface area for excellent heat transfer with minimum air resistance. Fins are equipped with collars that grip tubing for maximum contact area. Inverted coil circuiting prevents ice buildup at coil base in low ambients. Discharge gas enters bottom of coil during defrost and heat of refrigerant flows counter to water drainage resulting in extremely clean and unobstructed fins and tubes. Fin spacing allows rapid and com- plete water drainage. Flared tubing connections and silver soldering pro- vide tight, leakproof joints. Long life copper tubing is corrosion -resistant and easy to service. Coil is factory tested under high pressure to insure leakproof construction. Corrosion resistant PVC coated coil guard is fur- nished as standard. Entire coil is accessible for cleaning. NOTE — Specifications, Ratings and Dimensions subject to change without notice. ENGINEfthb DATA t? 1HEAT`0U'MPS MATCHED REMOTE SYSTEMS Page 17 October 1990 Supersedes December 1989 UO w+ah quo wmr mora �, coro�ewra na ustto 1 4 q,a.�� 4'ar..mr,aa tp Typical Application Copeland° Compliant ScrollTA, Compressor — High efficiency com- pressor features durability, steady uniform suction flow, constant discharge flow, high volumetric efficiency, quiet operation and the ability to start under any system load. Use of the scroll compressor eliminates the need for accumulator, crankcase heater, start capacitor and start relay. The compliant scroll type compressor is a simple compression concept design consisting of two involute spiral scrolls matched together to generate a series of crescent-shaped gas pockets between them. During compres- sion, one scroll is stationary while the other is allowed to orbit, not rotate, — around the fixed one. As this motion J occurs, gas is drawn into the outer pocket sealing off the open passage. As the spiral movement continues, the pockets between the scrolls are slowly t pushed to the center of the scrolls while simultaneously being reduced in vol- ume. When the pocket reaches the y center, the gas is now at high pressure'-�� and is forced out of a port located in _ the center of the fixed scroll. During compression, several pockets are being compressed simultaneously resulting in�- a smooth, nearly continuous compres- sion cycle. Continuous flank contact, maintained by centrifugal force, mini- J' mizes gas leakage and maximizes effi- ciency. The scroll compressor is tolerant to the effects of liquid slugging and contaminants. Should this occur, the scrolls separate and allow the liquid or contaminants to be worked to the center and discharged. Low gas pulses during compression minimize operational sound level. Factory installed muffler in discharge line, external to the compressor, provides additional sound reduction. Motor is internally protected from excessive current and temperature. Discharge temperature thermostat protects com- pressor from high discharge temperature. Compressor is installed in the unit on resilient rubber mounts, assuring vibration free operation. _1% ©1990 Lennox Industries Inc_ FEATURES Equipment Warranty — The compressor has a limited warranty for a full five years. All other components have a limited warranty for one year. Refer to Lennox Equipment Limited Warranty included with the unit for details. Weather Resistant Cabinet — Heavy gauge galvanized steel cabinet is subject to a five station metal wash process. This preparation process results in a perfect bonding surface for the finish coat of baked -on enamel. The outdoor enamel paint finish gives the cabinet long lasting protection from the weather. Drainage holes are furnished in the base and base channels for moisture removal. Heavy duty channels under the base raise the unit off the mounting surface away from the damaging moisture. Control box is conveniently located for easy access with all controls installed and pre- wired at the factory. Powerful Outdoor Fan — Efficient direct drive fan moves large volumes of air uniformly through the entire outdoor coil resulting in high refrigerant cooling capacity. Vertical discharge of air minimizes operating sounds and eliminates hot air damage to lawn and shrubs. Fan motor is totally enclosed for maximum protection from weather, dust and corrosion. A rain shield on the motor provides additional protection from moisture. Fan service access is accomplished by removal of fan guard. Corrosion resistant PVC coated steel wire fan guard is furnished as standard. Refrigerant Line Connections, Electrical Inlets and Service Valves — Vapor and:liquid line connections are located outside of the cabinet and are made with sweat connections. Brass service valves prevent corrosion and provide access to refrigerant system. Drier with internal check valve and strainer are factory installed in the liquid line. One-shot vapor valve, liquid line service valve and gauge ports are accessible outside of the cabinet. A field installed thermometer well is furnished. Refrigerant line connec- tions, valve "and field wiring inlets are all conveniently located in one cen- tral area of the cabinet. See dimension drawing. Defrost Control — A factory installed clock timer defrost control is fur- nished as standard equipment. It gives a defrost cycle for every 45 or 90 minutes (adjustable) of compressor "on" time at outdoor temperature below 35°F. A sensing element mounted on the outdoor coil determines when the defrost cycle is required. Defrost pressure switch on the liquid line terminates cycle. Expansion Valve — Designed and sized specifically for use in heat pump system. Sensor is located on the suction line between reversing valve and car -pressor thus sensing suction temperature in any cycle. Factory installed. Reversing Valve — 4 -way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. Timed -Off Control — Furnished and factory installed. Provides low voltage protection and prevents compressor short -cycling. Automatic reset control provides a time delay between compressor shutoff and start-up. Thermostat (Optional) — Thermostat is notfurnished with the unit and must be ordered extra. See Accessories Section, Page 13 and Lennox Price Book. Refrigerant Line Kits (Optional) — Lines are available in several lengths and must be ordered extra. See Refrigerant Line Kit table for selection. The refrigerant lines (vapor and liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at the factory. Vapor line is fully insulated. Lines are furnished with a flare fitting (Indoor unit connection) on one end and less any fitting (stubbed) on the opposite end for connec- tion to the outdoor unit. Refrigerant line length should not exceed 50 ft. in any installation. If longer length lines are required, contact your Lennox Division Service Manager. Mounting Base (Optional) — Rugged mounting base provides perma- nent foundation for outdoor units. High density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand "the rigors of the sun, heat, cold, moisture, oil and refrigerant. Will not mildew or rot. Can be shipped singly or in packages of 6 to a carton. HP20-211, HP20-261, HP20-311 and HP20-411 models use the MB1-22 base (99C78) 22-1/4" x 22-1/4" x 3" shipping weight 10 lbs. HP20-461 model uses the MBI -32 base (83C83) 32" x 34" x 3" shipping weight 15 lbs.. Outdoor Thermostat Kit (Optional) — An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable. Outdoor thermostat maintains the heating �'•!� load on the low power input as long as possible before allowing the full power load to come on the line. Thermostat kit (LB-29740BA) and mount- ing box (M-1595) must be ordered extra. Check and Expansion Valve Kits (Optional) — Must be ordered extra and field installed on indoor units. See ARI Ratings table. SPECIFICATIONS Model No. HP20-211 HP20-261 HP20-311 HP20-411 HP20-461 Outdoor Coil Net face area (sq. ft.) 9.24 7.39 7.39 9.24 11.39 Tube diameter (in.) 3/8 3/8 3/8 3/8 3/8 No. of rows 1 2 2 2 2 Fins per inch 120 20 20 20 18 Outdoor 3:Pan Diameter (in.) 18 18 18 18 22 No. of blades 4 4 4 4 4 Motor hp 1/6 1/6 1/6 1/6 1/3 Cfm 1900 2400 2400 2600 3800 Rpm 1170 1040 1040 1060 1060 Watts 150 250 250 260 400 Refrigerant -22 (charge furnished) 4 lbs. 5 oz. 6 lbs. 1 oz. 6 lbs. 1 oz. 6 lbs. 1E oz. 8 lbs. 5oz. Liquid line connection (sweat) 5/16 5/16 3/8 3/8 3/8 Vaper line connection (sweat) 5/8 5/8 3/4 3/4 7/8 Shipping weight (lbs.) 1138 148 148 170 217 Number of packages in shipment 111 1 1 1 1 —18— Outdoor tARI Standard 210/240 Ratings High Low Total Total Unit *Check Model No. CoolingTem P• Tem P• Total SEER EER Unit High Unit Low Indoor and *ARI' Std. Capacity Htg. Htg. Unit (Btuh/ (Btuh/ High„ HSPF Temp. Low Temp. Unit Expansion 2SRN lBtuhl Cap. Cap. Cooling Watt) Watt) Temp. Htg. Temp. Htg. Valve (Bels) ( IBtuh1 IBtuh) Watts Htg. C.O.P. Htg. C.O.P. Kit Watts Watts HP20-211 18,000 17,000 10,600 1830' 11.00 9.85 1615:6.9013.08 1470 2.10 C818-21 LB-34792BE (7.4)CBS18-21 23,600 22,600 13,400 2355 10.80 10.00 2135 7.00 3.10 1965 2.00 CB18-26 HP20-261CBS18-26 (7.6) LB-34792BE 23,800 22,600 13,200 2325 11.00 10.20 2040 7.10 3.24 1870 2.06 C819-26 CBH19-26 27,800 26,400 15,900 2866 10.90 9.70 2512 6.85 3.08 2284 2.04 CB19-26 CBH19-26 HP20-311 28,200 27,800 17,000 3095 10.05 9.10 2720 6.80 3.00 2430 2.04 CB18-31 LB-34792BG (7.6) CBS18-31 28,800 28,000 17,000 3075 10.25 9.35 2685 6.90 3.06 2405 2.08 C 18-41 .CB518-418-41 33,000 32,800 20,200 3575 10.25 9.25 3195 6.85 3.00 2890 2.04 CB18-41 CBS18-41 33,400 31,800 19,500 3479 10.90 9.60 3025 6.95 3.08 2747 2.08 CB19 41 HP20-411 CBH19 41 (7.8) LB-34792BG 34,600 33,000 20,400 3655 10.45 9.45 3150 6.90 3.06 2880 2.08 CB 18-51 CBS18-58-51 35,000 32,200 19,500 3425 10.90 10.20 2955 6.80 3.20 2660 2.16 CB2141 CBH21-41 38,800 39,500 22,400 4041 10.90 9.60 3640 7.20 3.18 3218 2.04 CB19-41 CB H 19-41 39,000 39,000 24,400 3980 11.00 9.80 3790 6.90 3.02 3305 2.18 CB2141 CBH21-41 HP20 461 40,000 40,000 25,200 4270 10.30 9.35 3840 7.15 3.06 3465 2.14 CB LB-34792BG (8.2) CBS18-58-5 1 43,000 40,000 23,000 4095 11.60 10.50 3552 7.20 3.30 3209 2.10 CB19-51 CBH19-51 43,500 40,000 24,800 4305 11.05 10.10 3690 7.70 3.38 3330 2.18 CB21-51 CBH21-51 *sound Rating Number in accordance with ARI Standard 270. tRated in accordance with ARI Standard 210/240 and DOE; with 20 ft. of connecting refrigerant lines. Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering Indoor coil air. h 'Heating Seasonal Performance Factor. �"iiub OO✓✓✓ •Kit must be ordered extra and field installed. -188- c L (7 ffff&�.(� CB18 SERIES - UP-FLO CBS18 SERIES - HORIZONTAL HEAT PUMP BLOWER -COIL UNITS *17,900 to 56,000 Btuh Cooling Capacity *17,500 to 62,000 Btuh Heating Capacity 6,400 to 102,400 Btuh Optional Electric Heat 'ARI Standard 240 Ratings with Matching Outdoor Unit CB18 Up -Flo C ENGINEERING DATA ,__... HEAT PUMPS MATC VED REMOTE SYSTEMS Pa a 32 August 1986 Supe 4 ary 1985 CBS18 Horizontal r, Compact Blower -Coil Heat Pump Units Feature -Efficient Operation and Application Flexibility The CB18 and CBS18 series blower -coil units are designed to meet reduced space requirements in apartment, motel, hotel and condominium applica- tions. These highly efficient units provide the answer to many difficult in- stallation problems. The flexibility of the units permit simple installations in a furred -in space, attic, crawl space, drop ceiling or closet. Versatile units are available in up-flo or horizontal models. Optional field installed electric heaters are available in several sizes to supplement heating capacity. For heating and cooling capacities see outdoor unit bulletins indexed in this section. Heavy gauge galvanized steel cabinet is completely insulated. Flare fittings provide quick and easy connection of refrigerant lines. Large CBS18 Horizontal Installation NOTE — Specifications, Ratings and Dimensions subject to change without notice. indoor coil is sized for maximum cooling efficiency. Direct drive blower has multispeed motor providing a choice of blower speeds. Optional elec- tric heaters are rated and tested according to Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. In addition, units have been tested with matching outdoor units in the Len- nox Research Laboratory according to ARI Standard 240 test conditions and DOE test procedures. Blower performance data is according to actual unit tests conducted in Lennox air test chamber. Blower -coil units and com- ponents within are bonded for grounding to meet safety standards for ser- vicing required by U.L. and NEC. Units are shipped factory assembled. CB18 Up -Flo Installation FEATURES Durable Cabinet - Constructed of heavy gauge galvanized steel and completely insulated with thick fiberglass insulation. The cabinets are subject to a five station metal wash process before painting. This preparation process results in a perfect bonding surface for the attractive finish coat of baked -on enamel. Removable panels provide complete service access. Lennox Indoor Coil - Extra large surface area of Lennox designed coil provides maximum cooling efficiency, excellent heat transfer and low air resistance. Precise circuiting gives uniform refrigerant distribution. Lennox fabricated coil is constructed of precisely spaced ripple -edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Long life copper tubing is easy to field service. Coil is thoroughly factory tested under high pressure to insure leakproof con- struction. CE18 models are equipped with dual coils in an "A" configura- tion. CBS18 models have a single slab coil. Drain Pan'- Deep, corrosion resistant drain pan has dual pipe drains extended outside of cabinet for ease of connection. See dimension drawings.. �. Refrigerant Line Connections - Vapor and liquid lines are equipped with flare fittings and extend outside of the cabinet for ease of connection. C818/CBS18-65 vapor line requires sweat connection. See dimension drawing for location. Transformer and Blower Cooling Relay (Furnished) - A 24 volt transformer and blower cooling relay are furnished as standard equipment and are factory installed. A terminal block is also furnished as standard. Powerful Blower - Equipped with a Lennox designed and built direct drive blower. Each blower is statically and dynamically balanced as an assembly before it is installed in the unit. Multispeed motor is resiliently mounted. A choice of blower speeds is avpilable. See blower performance charts. Change of blower speeds is easily accomplished by a simple change in wiring. Electric Heat (Optional) - Additive electric heaters field install internal to the unit cabinet and are available In seyeral kw sizes, see Electric Heat table. The helix wound nichrome bale heaog elements are exposed directly in the air stream resulting in instant heat tninsfer, low element temperatures and long service life. Each heating element is equipped with accurately located limit control with fixed temperature off setting and automatic reset. In addition, elements have supplemental thermal cutoff safety fuses providing positive protection in case of excessive temperatures. Cutoff fuses are mounted external to the element face plate for quick 'and easy replacement. Thermal sequencer relay brings the heating elements on and off line, in sequence and equal increments, with a time delay between each element. Sequencer also initiates and terminates blower operation. Heating control relay(s), is furnished as standard. Control box and access cover are constructed of heavy gauge galvanized steel. Heaters are factory assembled with controls installed and wired and only require plug-in field connection. Check and Expansion Valve Kits (Optional) - Kits must be ordered extra and field installed on the blower -coil unit. See kit table for requirement. Filter Kit (Optional) - Kit must be ordered extra and field installed. Filter box installs on return air opening external to the unit cabinet. A throwaway frame type filter is furnished on kits for CB18 up-flo models. Filter kits for CBS18 horizontal models are field assembled. Filter(s) are not furnished on kits for CBS18 horizontal models and must be ordered extra. Filter box has an access panel for removal and replacement of filter. See specifica- tion table and dimension drawings for details. SPECIFICATIONS Model No. CB18-21 CBS18-21 CB18-26 CBS18-26 CB18-31 CBS18-31 Net face area (sq. h.) 3.55 2.45 3.55 2.45 3.96 3.11 Tube diameter (in.) & no. of rows 3/8 -2 3/8 - 3 3/8-3 3/8-4 3/8-3 3/8 - 4 Indoor Fins per inch 17 15 16 13 15 14 Coil Vapor line connection (in.) -flare 5/8 5/8 5/8 5/8 •3/4 •3/4 Liquid line connection (in.) - flare 3/8 3/8 3/8 3/8 •1/2 •1/2 Condensate drain (mpt) in. (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 Shipping weight (lbs.) - 1 Package 98 95 100 100 114 121 Nominal cooling capacity (tons) 1-1/2 2 2-1/2 Refrigerant R-22 R-22 R-22 Blower wheel nominal diameter x width (in.) 9 x 7 9 x 7 9 x 9 Blower motor hp 1/6 1/6 1/3 Electrical Characteristics 208/230 volts - 60 hertz - 1 phase - All Models *Optional Fart No. LB-51905BA LB -568958A LB -519050A LB -568958A LB-51905BB LB-56895BB Filter Filter size (in.) •(1) 16x20x1 tt(1) 20x25x1 9(1) 16x20x1 tt(l) 20x25x1 •(1) 16x25xl tt(2) 16x20x1 Kit Shipping weight (lbs.) 5 25 5 25 8 : 23 ECB18 2.5 Output Btuh 9,500 9,500 9,500 9,500 - -- tA.F.U.E. 1 100% 98.5% 100% 98.5% --- - EC818-5 Output Btuh 18,000 18,000 18,000 18,000 18,000 18,000 tA.F.U.E. 100% 98.5% 100% 98.5% 100% 99.0% ECB18-6 Output Btuh 22,000 22,000 22,000 22,000 22,000 21,000 tA.F.U.E. 100% 98.5% 100% 98.5% 100% 99.0% Optional Electric ECB187 Output Btuh 25,000 25,000 25,000 25,000 25,000 25,000 tA.F.U.E. 100% 98.5% 100% 98.5% 100% 99.0% Heat Capacity ECB18-8 Output Btuh 29,000 29,000 29,000 29,000 29,000 28,000 tA.F.U.E. 100% 98.5% 100% 98.5% 100% 99.0% ECS18-10 Output Btuh 36,000 35,000 36,000 35,000 36,000 35,000 tA.F.U.E. 100% 99.0% 100% 99.0% 100% 99.0% EC818-12.5 Output Btuh --- --- 44,000 - 1 44,000 1 43,000 tA.F.U.E. ---- ---- 100% -- 100% 99.0% ECB18-15 Output Btuh ---- --- -- -- 52,000 52,000 tA.F.U.E.---- ---- -- - 100% tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. *Must be ordered extra for field installation. -Filters are furnished with kit. 1tFilters are not furnished and must be ordered extra. its/8 MF x 3/4 FF adapter required with HP16-211V and HP16-261V outdoor unit. 4,3/8 MF x 1/2 FF adapter required with HP16-211V and HP16.261V outdoor unit. WA W SPECIFICATIONS Model No. C818-41 CBS18-41 CB18-61 CBS18-51 CB18-65 CBS18-65 CBS18-51 Net face area (sq. ft.) 4.22 3.50 4.67 5.45 5.25 5.45 Indoor Tube diameter (in.) & no. of rows 3/8-3 3/8-4 3/8-4 3/8-3 3/8-4 3/8-4 Coil Fins perinch 15 13 13 16 16 16 HP16411V Vapor line connection (in.) -flare 3/4 3/4 3/4 3/4 ,Ir1-1/8 sweat *1-1/8 sweat CBS18-51 Liquid line connection (in.) - flare 1 1/2 1 1/2 1/2 1/2 1/2 1/2 Condensate drain (m t) in. (2) 3/4 1 03/4 (2) 3/4 (2)3/4 (2) 3/4 (2) 3/4 Shipping weight (lbs.) - 1 Package 114 1 124 162 175 178 201 Nominal cooling capacity (tons) 3 4 5 Refrigerant R-22 R-22 R-22 Blower wheel nominal diameter x width (in.) 9 x 9 10 x 9 1 9 x 9 11-1/2 x 9 1 11-1/2 x 9 Blower motor hp 1/3 1/2 3/4 Electrical. Characteristics 208/230 volts -60 hz-1 phase 208/230 volts - 60 hz - 1 phase or 460 volt - 60 hz - 1 phase *Optional.! Part No. LB-51905BB LB-56895BB LB-51905BC LB-56895BC LB-51905BC LB-56895BC Filter ":: Filter size lin.) 9(1) 16x25x1 tt(2) 16x20x1 •(1) 20x25x1 tt(4) 16x20x1 •11) 20x25x1 tt(4) 16x20x1 Kit ?. Shipping weight (lbs.) 8 23 9 35 9 35 ECB18-5 Output Btuh 18,000 18,000 tA.F.U.E. 100% 99.0% EC818 6 Output Btuh 22,000 21,000 -- - _ tA.F.U.E. 100% 99.0% ---- ---- ---- ---- ECB18-7 Output Btuh 25,000 25,000 26,000 26,000 -- -- tA. F.U.E. 100% 99.0% 100% 99.0% -- -- ECB18 8 Output Btuh 1 29,000 28,000 30,000 29,000 tA.F.U.E. 1 100% 99.0% 100% 99.0% - - Optional Electric ECB1810 Output BtLh 1 36,000 35,000 37,000 36,000 37,000 36,000 tA.F.U.E. 100% 99.0% 100% 99.0% 100% 99.0% Heat Capacity EC818-12.5 Output Btuh 44,000 43,000 45,000 44,000 46,000 45,000 tA.F.U.E. 100% 99.0% 100% 99.0% 100% 99.0% EC818-15 Btuh 52,000 52,000 54,000 53,000 54,000 54,000 tA.F.U.E. 100% 99.3% 100% 99.1% 100% 99.1% ECB18-20 Output Btuh - --- 71,000 70,000 71,000 71,000 tA.F.U.E. - - 100% 99.1% 100% 99.1% ECB18-25 Output Btuh -- -- - __ 88,000 87,000 tA.F.U.E. - - --- 100% 99.2% ECB18-30 Output Btuh - --- _ __ 105,000 104,000 tA.F.U.E. -- --- -- - 100% 99.2% imrinuai ruai umaauon trriciency oasea on Uut test procedures and according to FTC labeling regulations. •Must be ordered extra for field installation. *Filters are furnished with kit, ttFilters are not fumished and must be ordered extra. *Field provided adapter fining required with HP16-511V outdoor unit. CHECK AND EXPANSION VALVE KITS Blower -Coll Unit Outdoor Unit 'Check and Expansion CB18-51 Model No. Valve Kit CB 18-21 CBS18-51 1000 CBS18-21 H P18-211 V LB-34792BE C818-26 CBS18-26 CBS18-41 CBS18-26 HP18-261V LB-34792BE CB18-31 HP16-211V, HP16-261V LB-34792BE CBS18-31 HP18-311V LB-34792BG CB 18-41 H P16-311 V 1 inch CBS18-41 HP18-411V-413V LB -347926G CB18-51 HP16411V CBS18-51 HP18461V LB 347928G C818-51 H P16-461 V CBS18-51 HP18-511V-513V LB-34792BF CB18-65 HP16-511V LB-34792BF CBS18-65 HP18-651V-653V LB-34792BH 'Kit must be ordered extra and field installed. INSTALLATION CLEARANCES 'Within 3 ft. of the unit. BLOWER DATA AIR FILTER RESISTANCE Air Volume (cfm) CB18.21 CB18-31 CB18-51 Model No. CBS18-21 CBS18-31 CBS18-51 1000 CB18-26 CB18-41 CB18-65 1400 CBS18-26 CBS18-41 CBS18-65 Cabinet 0 inch 0 inch 0 inch Plenum 0 inch 1 inch 1 inch *Duct 0 inch 1 inch 1 inch 'Within 3 ft. of the unit. BLOWER DATA AIR FILTER RESISTANCE Air Volume (cfm) Filter Resistance (in. wg.) 400 .01 600 .02 800 .03 1000 .05 1200 .08 1400 .08 1600 1 .08 1800 .09 2000 .09 2200" .10 2400 .10 - 34a - PRODUCT': MIN, FIB WTRC=-HTR KITS & DUCT- & PIPE WRAP -- -- L< MANUFAGTUREFt .OR PRIVATE LABEL:.,:.,REG NO-.- CA-T04O(CO).' _. PAGE' 193 MANVILLE SALES CORP. BRAND PRODUCT.. MATERIAL TYPE FACING PRIMARY-- DESIGNED ACTS AS LABELED LABELED "ODE * ID USE FOR VAPOR PRODUCT THERMAL' EXPOSED BARRIER? THICKNESS PERFORM - .R APPLICR'. ` INCHES ANCE IN :.. ; TIONS? R, K, OR C VALUE ----------------------- --------------------------------------� ---------------------------------------------------------- ;-- IAN MICROLITE WH FIBER GLASS SINGLE MATERIAL-. NONE WATER HEATERS YES NO .1.25 0.28 K LAN MICROLITE WH FIBER GLASS SINGLE MATERIAL NONE WATER HEATERS YES NO. 1.50 0028 K. LAN MICROLITE WH FIBER GLASS SINGLE MATERIAL NONE WATER HEATERS YES NO 1.75 0.28 K LAN MICROLITE WH FIBER GLASS SINGLE MATERIAL NONE WATER HEATERS YES NO 2.00 0.28 K LAN MICROLITE WH FIBER GLASS SINGLE MATERIAL NONE WATER HEATERS YES NO 2.50 0.28 K [AN MICROLITE WH FIBER GLASS SINGLE MATERIAL NONE WATER HEATERS YES NO 3.00 0.28 K [AN R'=SERIES DW FIBER GLASS SINGLE MATERIAL NONE DUCTS YES NO 1.00 3.20 R LAN R -SERIES DW FIBER GLASS SINGLE MATERIAL NONE DUCTS YES NO 1.50 ;4.50 R [AN R -SERIES DW FIBER GLASS SINGLE MATERIAL NONE DUCTS YES NO 2.00 6.00 R [AN R -SERIES DW FIBER GLASS SINGLE MATERIAL NONE DUCTS YES NO 2.50 7.50 R [AN R -SERIES DW FIBER GLASS SINGLE MATERIAL NONE DUCTS YES NO 3.00 9'.00 R. AN R-StRIES DW FIBER GLASS FACED SINGLE MTL. MTL/PLAS DUCTS YES YES 1.00 3.20 R :AN R -SERIES DW FIBER GLASS FACED SINGLE MTL. MTL/PIAS DUCTS YES YES 1.50 4.80 R :AN R -SERIES DW FIBER GLASS FACED SINGLE MTL. MTL/PLAS DUCTS YES YES 2.00 6.50 R AN R -SERIES DW FIBER GLASS FACED SINGLE MTL. MTL/PLAS DUCTS YES YES 2.50 8.10-R AN R -SERIES DW FIBER GLASS FACED SINGLE MTL. MTL/PLAS DUCTS YES YES 3.00 9.70 R Y� DESCRIPTION OF BRAND. CODES MAN -MANVILLE-SALES CORP 27 -Jun -89