BLCK (11389) + SFD (10934)52220 Avenida Madero
11389
10934
Building 52-220 MADERO
Address
Owner
DAVID MILLER
Mailing
Address P 0 BOX 722
City Zip
LA QUINTA 92.253
Contractor
PACIPID TRADES
SAME
4.14
•
P.O. BOX 1504 N o . 11389
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
Tel.
565-5823
Tel.:
State Lic. I City_
& Classif. 425381 Lic. # Y955
Arch:, Engr., --
Designer
Address Tel.
City I Zip I State
Lic. #
t LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under, provisions of Chapter 9 (commencing with Section
t
7000 t? Divisions 3, ot theF usiness and P' fessiohs Code, and my license is in full'iforce and
SIGNATDRE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Lawfor the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, atter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a. signedstatement' that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
'Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation- of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than rive hundred dollars (S500).
O I, as owner of_the property, or my employees with wages as their sole, compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044,'Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not Intended or offered for safe. It, however, the building
or Improvement is sold within one year of completion, the owner -budder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con•
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of propefty,who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to Me- Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. .Company
❑ Copy is filed with the city.. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation.
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any. manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked..
CONSTRUCTION LENDING AGENCY '
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
-This is a building permit'when'properly filled out, signed and validated, and is subject to
expiration it work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING: TYPE CONST. OCC: GRP.
A.P. Number
Legal Description
Project Description GARDEN' MALL 4 g 20 f
IVIHL l yr liJ.trJ I
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front.Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date - Permit
fi
Validated by:
Validation:
Sq. Ft.
Size
No. No. Dw.
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
'. AMOUNT
Plan Chk. Dep.
.Plan Chk. Bal.
Const.
$ Lx6. 00
Mech.
Electrical
Plumbing
S.M.I.
.05-
05.Grading
Grading
Driveway Enc.
Infrastructure
k: .i _s•Y. i .Frf •I ? ' •' •fit k ,.' '' ' i .i , m "'
IVIHL l yr liJ.trJ I
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front.Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date - Permit
fi
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL SQ. FT. ® $
2ND FL SQ. FT. ®
POR. SO. FT. ®
GAR. SO, FT. ®
CAR P. SO. FT.
WALL SQ. FT. ®
SQ. FT. ®
ESTIMATED CONSTRUCTION VALUATION $
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM
BAR SINK
ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN.
URINAL
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
HEATING (ROUGH)
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
DUCT WORK
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
METER LOOP
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM. FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SQ. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 11/4 c
SEWAGE DISPOSAL
=$
SO.FT.GAR ® 3/ic
HOUSE SEWER
FINAL INSP.
FRAMING
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE — "I" PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APP./EQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM Zl
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
VY,
REMARKS:
VENTILATION
FIRE ZONE ROOFING:
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
. FINAL INSPECTION- `tel
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES11NITIALS
GARDEN WALL FINAL
P.O. BOX 1504 No. 10934. 1
Building 52--220 Madero LA QUINTA CAL FORNIA 92253
Address ;
Owner
David Diller
Mailing
r BUILDING: TYPE CONST. OCC: GRP.
_-- ;, -
'L ..Address P. S?. Box .722 f a% A.P. Number •'73--203--0'11
City Zip Tel-
La'.Quinta 92253 .564-5923• Leg al. Description
Contractor
C. ;e Project Description SFD
Pacific* fi c* 'n. radei c
Address...
same
Al 10
City. Zip'Tel.:
State Lic., City
& Classif.- , . B 425381 Lic. # 1955 Sq. Ft. No: No. Dw.
Size Stories Units ,
Designer New ❑ Add'❑Alter:❑ Repair ❑ Demolition ❑
Address Tel. Permit does not.'inolude black walls
CityZip Statear pool
Lic. #
_ LICENSED CONTRACTOR'S DECLARATION. 1 'i'
I hereby affirm that am licensed under provisions of Chapter 9 (commencing with Section
7000) of Drvislon 31of the Business and Professions' Code, and my license rs in full force and
effect Eklod
•SIGNATURE --- ' . '"""^`"+sv.n DATE -'
"" -' ,," OWNER -BUILDER DECLARATION
I hereby affirm that I am.exempt from the Contractors License Law`for the following.- Estimated Valuation e • r
reason: (Sec. 7031.5,Business and Professions Code: Any,cRyor.:cmatty which requires a V o
Permit to construct, alter, Improve, demolish, orrepair any struchae, prior to its issuance, also - - -
requires the. applicant for such permit to file a signed statement that he is Licensed pursuant toPERMIT .AMOUNT •
the provisions of the, Contractor's License Law, Chapter 9 (comnenofng with Section 7000) of- '
Division 3 of the Business and Professions Code, or that: he is exempt therefrom, and the basis `w•=s p t
for the alleged exemption. Any violation of Section 7031.5 byany applicant for a permit Plan Chk. Dep. _ -",250.00
; subjects*the applicant to a civil penalty of not more than five hundred donars (5500). ' I • I - c
property, r P Y 9 peo t;or, .N q, `t J Plan Chk: Bal. - ' 211 a j 4
0. I, as owner of the.or m employees ees with wages as their sole com • e1
• +do the7 work, and the structure Is not Intended or offered for sale. (Sec. 7044, Buisness and` { Const:
, Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or Improves thereon, and who does such work 'himself or .through his own empfoyees, Mech =- _ _ 5 0
provided that such improvements are not intended or offered for safe. H, however, ,the' building '
or improvement is sold within .one year of completion, the-owner-buddar w® have the burden•z-••„ t [R
., of proving that he did not build or Improve for the purpose of sale.) _ Electrical -117.10
+ ,t 7 1.10
❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing. :i 141.00
struct the project. (Sec. -7044; Business and Professions Code: The Contractors License Law •• ..
does not apply to an owner of property who builds or improves thereon, and who contracts for . S•M•I; --7i.70
,
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ,. g r 20.00
. ❑ I am exempt under Sec.. B. & P.C. for this reason -
Gradin:
Driveway Enc. 20.00
•' Date owner Infrastructure 16180:05
WORKERS' COMPENSATION DECLARATION' 1 ,•r
I hereby affirm that I have a certificate 'of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800,. Labor. Code.)
Policy No. Company
Copy is filed with the city. .❑ Certified copy is hereby furnished.
TOTAL 30:3U 9.9 1 2758.99
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS' COMPENSATION INSURANCE •
(This section need not be completed if the permit is for one hundred dollars .(S100) valuation
or less.) . .
I certify that in the performance of lhg work for which this permit is issued,'I shall not
-employ any person in any manner so as to become subject to the Workers' Compensation,
Laws of California. +
' Date Owner
NOTICE TO APPLICANT: Il, ager making this Certificate- of Exemption you should become ZONE: '' BY: -
subject to the Workers' Compensation provisions of the Labor -Code. 'you must forthwi0i Minimum Setback Distances: -
comply with such provisions or this permit shall be deemed revoked. `' - - Front. Setback from Center Line
Rear Setback from.Rear Prop..Line* '
CONSTRUCTION LENDING AGENCY - Side Street Setback from Center Line
I hereby affirm that there is a construction lending agency for the perfomlance'of the
work for which this permit is issued. (Sec. 3097; Civil code.) Side Setback from Property Line
Lender's Name
Lender's Address FINAL DATE INSPECTOR `
• This is a building permit when properly filled out, signed and validated, and is.subject to . -
expiration it work thereunder is suspended for 180 days. ; c
,1 certify that I have read this application and state that the above information is correct. Issued by: Date Permit -
'.'I agree to comply with all city and county ordinances and state laws relating to building - • r..; +, e,.,,., "•`
construction, and hereby authorize representatives -of this city to -enter the •above-.
mentioned property for inspection purposes_. Validated by:
Signature of applicant Date
Mailing Address Validation:
City, State, Zip
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
IST FL. SO. FT. ® $
2ND FL. SO. FT.
POR. SQ. FT. ®
GAR. SQ. FT. ®
CAR P. SQ. FT.
WALL SO. FT. @
SO. FT ®
ESTIMATED CONSTRUCTION VALUATION $
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM
BAR SINK
ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN.
URINAL
WATER PIPING
NOTE: Not to be used as property tax valuation
ROUGH PLUMB. BONDING
FLOOR DRAIN
MECHANICAL FEES
FORMS
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
OTHER APPJEOUIP.
LAUNDRYTRAY
AIR HANDLING UNIT CFM
GAS (FINAL) TEMP. POLE
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SQ. FT. ® c
BATH TUB
FINAL INSP. tQ
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 1 V4 c
SEWAGE DISPOSAL
SO.FT.GAR ® V4c
HOUSE SEWER
VENTILATION
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING 1(711.2, efIc UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB. BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
EWER OUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF.ay
GAS (ROUGH) ( /17l METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL) TEMP. POLE
GROUT
WATER HEATER SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP. tQ
FRAMING 12 IQ
FINAL INSP.
ROOFING /
i h
— /c( n ` 1/
Wij— op
REMARKS:
VENTILATION
FIRE ZONE ROOFING '
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
RING
MESH
INSULATION/SOUND !, _
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES11NITIALS
GARDEN WALL FINAL
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated 4
(619) 347-8631
Date 7/16192 1 Type of Permit I La Quinta
No. 11571 Permit #
Log #
Owner Name David Miller
No. 52220 street Madero
city La Quinta zip 92253 Study Area 113
APN # Tract # Lot # Square Footage 11257
Type of Development I Single Family Residence No. of units
Comments Square fontagP was nmittPd from pt-rmit p= lination_ ITnahIP to verify with
Building Dpj artmP.nt_ PIP.aRPyP.rlfy at time of nP.rmit issuanrn
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 11.58 1 X 1 57 or $ 1,986.06 have been paid to D.S.0 S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued
Fees Paid By David R. Miller
Name on the check
By James E. Lively
Assistant Superintendent, Business Services
Fee collected /exempted by Shelley D. Bennett
Signature
Telephone 564-5501
17
Collector: Attach a copy of county or city plan check application form to di
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy -
11 Vii% ,
ivied
ti X
Check .dh04 A-414
y
COASTAL COUNTIES ESCROW
.74-350 ALESSANDRO, SUITE A-2
PALM.DESERT, CALIFORNIA 92260t.
(619).340-2592 U
SALE ESCROW INSTRUCTIONS
TO: COASTAL COUNTIES ESCROW'
_DATE: April 22 1992
ESCROW NO: 4821-J
ESCROW OFFICER: Jackie Feldman
PROPERTY ADDRESS: Vacant Land
La Quinta, CA 92253
:Cash.through escrow...... $ 21,500.00
:Total Consi.deration...... $ 21,500.00
On or before 06/08/92, I will hand you,,or cause to be handed you, the sum of
$21,500.00, of which the sum of $500.00 has been handed the broker for deposit herein
and will deliver to you any instruments executed by me that'are called for below, and
any additional funds to enable you.to comply with these instructions: all of which
together will equal the total consideration herein'of $21,500.00, which you shall
deliver when you can obtain a Grant Deed to the hereinafter described property and a
C.L. T.A. Standard Form Policy of Title Insurance with liability equal to the total
consideration.herein, on the following described real property in the State of
California, County of Riverside, being:
Lot 11 in block 37, Santa Carmelita at Vale La Quinta, Unit No. 3, as per map ;
recorded in book 18, page 59 of maps in the office of the County Recorder of said
County.
Showing title vested in:
David Ross Miller, -a married man as his sole and separate 'property (Escrow Holder
will prepare a deed to, reflect the above vesting)
SUBJECT ONLY TO:installment(s) of General and Special County Taxes, assessments
of any governmental body, including'district levies, payments of which are included
and collected therein, for current fiscal year, not delinquent,, including taxes for
the ensuing year, a lien not payable.
B) Covenants, conditions, restrictions, easements, rights of way and :the exception
and reservation of any oil, gas,- water and hydrocarbon.,substances, on or under.said
land, now of record and/or reserved in deed to file, if any, affecting the use and
occupancy of said land.,
C) Bonds and assessments are to be paid current by seller and assumed;by buyer. Sewer
has been paid by seller.
INSTRUCTIONS:
Buyer agrees to cooperate with the sellers in consumating a 1031 tax deferred
exchange at no additional cost to the buyers.
SELLER(s) agree to hand escrow holder a duly executed 1099/1096 Information
Authorization for the report of Real Estate Transaction in accordance with Internal
Revenue Code Section 6045(e). BUYER and SELLER are aware the closing of this escrow
may be.delayed until such time as SELLER has complied with the 1987 Tax Reform Act as
set forth herein.
Buyer and seller are.aware.that the property.will be reassessed upon change of
ownership. A supplemental tax bill will be received which may reflect an increase or
decrease in taxes based on the property value. If there is an impound for taxes with
a lender,. the amount of the periodic impound payment may change.
Pro -rate taxes to close of escrow.
AS A MEMORANDUM IN THIS ESCROW, WITH WHICH COASTAL OOUNTIES ESCROW, SHALL NOT BE
CONCERNED, IT IS AGREED BY AND BETWEEN THE PARTIES HERETO THAT:
Seller agrees to allow buyer to install builders sign on property during escrow
period.
The foregoing terms, covenants and conditions, as.well as the ESCROW INSTRUCTIONS
attached hereto, which are incorporated herein, have been read, accepted and approved
by me. Deliver title insurance policy to insured. Instruct County recorder to mail
deed to me. Start search of title at once. I pay buyer's escrow fee, recording deed
and new loan instruments, if any, lender's transfer or new loan,fee, if any, first
year's hazard insurance premium, if any, Trustee's -service fees,.if any. -
David Ross Miller
of A
&. DAN RILEY
e ' v Sealer, Welghts & Measures '
n (7.14) 275 3030
OFFICE OF
AGRICULTURAL COMMISSIONER
JAMES O., WALLACE, Commissioner
83-612 Avenue 45 Suite 7
-Indio, CA 92201
DEVELOPER'S NAME: • - : _ L 2 d 5
ADDRESS:
r
TELEPHONE:
S Z - ZZ
Dear Developer:
After reviewing your landscaping plans, all plant material listed is not in
violation of quarantine laws governing the Coachella Valley. If substitutions
do occur and they differ from plant material listed, this office must be notified
immediately.
Thank you for protecting and preserving the Coachella -Valley's pest -free environment.
Agricult cil Commissioner's.Office
cc: Indio and Riverside
I
- 4080 LEMON STREET; ROOM 19, RIVERSIDE, CALIFORNIA 92501 FAX (714) 275-3012
-=Jill ENERGY CONSULTING GROUP
Indian Hills fox 34F
I Mountain Center, CA 92361` Lic 473969
I
January 7, 1992
DAVE MILLER
PACIFIC TRADES
LA QUINTA, CA
INVOICE
1 Set Residential Title 24 Compliance Reports $100.00
Than you,
W. J.. Finnell
Residential & Commercial Energy Consultants 1-800-26279966
ENERGY CONSULTING GROUP
Indian Hills Box 34F
Mountain Center, CA 92361 "Lic 473969
The following are some explanatory notes concerning the
enclosed forms:
C2R The compliance margin is a positive number --the
building,_ as described in these reports, complies
with the-California.Energy.Commission requirements.
CF -1R Page 2 should be signed by the building designer
and owner. Please note any remarks that may appear
in the "Special Features/Remarks" section. These
components are required -standards for your build-
ing. Also, the brand name and model number of -
the furnace, air conditioning and hot water systems
you plan to install should be entered.
MF -1R Lists the mandatory items -required by the California
Energy Commission. This form needs to be completed
by the builder or owner.
HVAC SIZING calculations are used to indicate the basic
heating and air conditioning requirements (Btu) for
Your particular building. Please note that this is
a guideline and the person selecting this. equipment
needs to consider all factors involved (such as air
flow restrictions, safety margins, etc.) when
making these choices.
Please contact us if you have any questions concerning
this compliance package.
Thank you,
W. J. Finnell.
Enclosures
Residential & Commercial Energy Consultants 17800-262-9966
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title. PACIFIC Date. 01/07/92
Project Address........ LA QUINTA _________________
Documentation Author... W J FINNELL
Company ................ ENERGY CONSULTING GROUP Building Permit #
Telephone .............. 1-800-262-9966
;Plan Check / Date '
Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15
--------- --------------------------------------
-------------------------------------------------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R
_-_User#_MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
------------------------------------------------------------
= MICROPAS3
----------------------------
ENERGY USE
SUMMARY
=
_
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
Design
--- --
Design
Margin
= Space Heating..........
-
733.86--
6.73
----
---- --
2.87 -
= Space Cooling...........
48.63
41,08
7.55 -
= Water Heating..........
14.88
21.97
-7.09 =
= Total
70.24
66.91
3.33 =
_ *** Building complies
with Computer Performance ** _
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 1257 sf
Building Type .............. Single Family Detached
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units'..., 1
Number of Building Stories.. 1
Weather Data Type............ ReducedYear
Floor Construction Type..... Slab On Grade
Number of Building Zones... 1
Conditioned Volume......... 10936 cf
Footprint Area........... 1257 sf
Slab -On -Grade Area......... 1257 sf
Glazing Percentage.......... 10.8 % of FA
Average Ceiling Height..... 8.7 ft..
BUILDING ZONE INFORMATION
-------------------------
Floor # of
(Package D)
0
Cond- Area Volume Dwell Thermostat
Zone Type itioned (sf) ( cf ) Units Type
-------- --------- ----- ------------
HOUSE
Residence Yes 1257 10936 1.00 Setback"
Vent Special
Height Vent Area
(ft) (sf)
2.0 n/a
COMPUTER
METHOD SUMMARY Page
2
C -2R
Project----------------------------------------
Title.......... PACIFIC Date..
.01/07/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM
C -2R
'
-----------------------------------------------------------------------------
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
'
OPAQUE SURFACES
Area
U- Insul Act Solar Location/
Form
3
Surface
(sf)
-
value R-val Azmth Tilt Gains Comments
-----
Reference
HOUSE
---- -------------------
-- ------
1 Wall
1.10
0.065 R-19 90 90 Yes OUTSIDE
None
2 Wall
160
0.065 R-19 90 90 No GARAGE
None
3 Wall
268
0.065 R-19 180 90 Yes OUTSIDE-
None
4 Wall
247
0.065 R-19 270 90 Yes OUTSIDE
None
5 Wall
249
0.065 R-19 0 90 Yes OUTSIDE
None
6 Roof
1257
0.029 R-38 0 0 Yes ATTIC,
None.
7 Door
20
0.330 R-0 90 90 Yes FWALL
None
PERIMETER LOSSES
----------------
Length F2 Insul
Surface
(ft.) Factor R -vat. Location/Comments
HOUSE
-- ----------------------
8'S1abEdge
9 0.900 R-0 OUTSIDE
9 S1abEdge
116 0.720 R-0 OUTSIDE
10 S1abEdge.
20 0.500 R-0 GARAGE
GLAZING SURFACES
----------------
Area #
SC
of Frame Open ' U- Act Glass
Interior
Shade
SC
Gls+
Surface
(sf) Panes Type _ Type value:Azmth Tilt Only
------
Type
Shade
HOUSE
----- ----- ---- -----
-----
1 Window
26.0
2 Metal Slider 0.65 90 90 0<77
drapes
0.66
2 Window
16.0
2 Metal Slider 0.65 180. 90 0.77
drapes
0.66
3 Window
49.0
2 Metal. Slider 0.65 270 90 0.77
drapes
0.66
4 Window
45.0
2 Metal Slider 0.65 0 90 0.77
drapes
0.66
EXTERIOR SHADING
----------------
Area Shading SC of
Surface { sf ) Type Ext Shade
----- ---------
HOUSE.
1
Window 26.0 50% bug scrn 0.84
2
Window 16.0 50% bug scrn 0.84
3
Window 49.0 50% bug scrn 0.84
4
Window 45.0 50% bug scrn 0.84
COMPUTER METHOD SUMMARY
Page 3 C_ 2R
-----------------------------------------------------------
----------------------------------------
Project Title.......... PACIFIC Date....... 01/07/92
------------- --------------------------------------=--
-------------------------------------------- --
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R '
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
-------------------------------------------------------------------------------
THERMAL MASS
HVAC SYSTEMS
Area
Thick
Heat
Conduct -.Surface
System Type
Efficiency
Mass Type
(sf)
(in)
Cap
--
ivity
--------
R -value
Location/Comments
HOUSE
HeatPump
8.0 HSPF
Attic
R-5
--------
------------------=- ---
1 S1abOnGrade
210
3.5
28.0
0.98
R-0.0
KIT/DINE/BATHS
2 S1abOnGrade
1047
3.5'
28,0
0.98
R-2.0
REST OF HOUSE
3 InteriorHorz
54
1.0
24.0
0.67
R-0.0
KITCHEN/BATHS
4 InteriorVert
72
4.0
21.0
0.59
R-0.0
LIVING
HVAC SYSTEMS
WATER HEATING SYSTEMS
---------------------
Minimum
Duct
Duct
Duct
System Type
Efficiency
Location
----------
R -value
Efficiency
HOUSE
(Btuh) Credits
Storage
-------
----------
HeatPump
8.0 HSPF
Attic
R-5
0.828
AirCond
10.00 SEER
Attic
R-5
0.818
WATER HEATING SYSTEMS
---------------------
SPECIAL FEATURES/REMARKS
Capa-
R-12 or
Pilot
System
# of city
Greater Effic- Standby Input
Size
TypeHeat
-----
(gal)
Blanket' iency Loss Rating
------
(Btuh) Credits
Storage
------ ------------
-------- -------
Electric
1 37.0
No 0.99 RE .82% 4.5 kW
n/a Recovery
SPECIAL FEATURES/REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
-----------------------------------------------------
------------------------------
Project Title.......... PACIFIC Date......... 01/07/92
Project Address.. .. LA QUINTA
Documentation Author... W J FINNELL
Building Permit #
C6mpany................ ENERGY CONSULTING GROUP
Telephone .............. 1-800-262-9966 ; Plan Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date
Climate Zone........... 15 ------------------
__________________________________________________________________
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R
User#_MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
-----------
-------------------------------------------------------
GENERAL INFORMATION
Conditioned Floor Area..... 1257 sf
Building Type. .............. Single Family Detached
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units... 1
Number of Stories........ 1
Floor Construction Type.... Slab On Grade (Package D)
Infiltration Control....... Standard
BUILDING SHELL INSULATION
Component
Insul
Type
R -value
Wall
R-19
Roof
R-38
Door
R-0
S1abEdge
R-0
Location/Comments
OUTSIDE, GARAGE
ATTIC
FWALL
OUTSIDE, GARAGE
Area
Type (sf )
------------ ------
S1abOnGrade 210
S1abOnGrade 1047
InteriorHorz 54
InteriorVert 72
THERMAL MASS
------------
Thickness Hard Surfaced/
(in) Exposed
--------- --------------
3.5 Yes
3.5 No
1.0 Yes
4.0 Yes
Framing
Overhang
Type
None
GLAZING
None
Glazing
None
Metal
Area
# of
Interior
Exterior
Orientation
(sf)
Panes.
-----
Shading
Shading
Window
Front
( E )
26.0
2
----------
drapes
--------------
50% bug scrn
Window.
Left
(S)
16.0
2
drapes
50% bug scrn
Window
Back
( W )
49.0
2
drapes
50% bug scr n
Window
Right
( N )
45.0
2.
drupes
50% bug scrn
Area
Type (sf )
------------ ------
S1abOnGrade 210
S1abOnGrade 1047
InteriorHorz 54
InteriorVert 72
THERMAL MASS
------------
Thickness Hard Surfaced/
(in) Exposed
--------- --------------
3.5 Yes
3.5 No
1.0 Yes
4.0 Yes
Location%Comments
KIT/DINE/BATHS
REST OF HOUSE
KITCHEN/BATHS
LIVING
Framing
Overhang
Type
None
Metal
None
Metal
None
Metal
None
Metal
Location%Comments
KIT/DINE/BATHS
REST OF HOUSE
KITCHEN/BATHS
LIVING
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Page 2 CF -1R
Project Title.......... PACIFIC Date.. ..01/07/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R '
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC
-----------------------------------------------------------------------------
ASSUMED HVAC
SYSTEMS
` Assumed
Duct
Duct
Assumed System Efficiency
Location
R -value
HeatPump 8.0 HSPF
Attic
R-5
AirCond 10.00 SEER
Attic
R-5
ACTUAL HVAC SYSTEMS
Actual Output Manufacturer and Model #
Actual System Efficiency (Btuh) (or approved equal)
------- ---------------------------
Heating -
Cooling
Cooling Coil
CEC Maximum output for Gas Central Furnaces., Btuh
WATER HEATING SYSTEMS
Tank R-12 or
# of Vol Greater Manufacturer and Model # Energy
System Type. Heat ( gal) Blanket (or approved equal) Credits
------- ---------------------------- ----------
Storage, Electric 1 37.0 No WATERMISER 40FESL Recovery
SPECIAL FEATURES/REMARKS
------------------------
n
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Page 3 CF -1R
--------------------------------------
Project Tit.le.......... PACIFIC Date.. .. 01/07/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R '
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
---------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1 of the California Administrative code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this certificate of compliance is submitted for a single building plan to
be built in multiple orientations, all building- conservation features
which vary are indicated in the Special Features/Remarks section:
Name....
Company.
Address.
Phone...
License.
Signed
DESIGNER' OWNER
( date )
DOCUMENTATION AUTHOR
Name.... W J FINNELL
Company. ENERGY CONSULTING GROUP
Address. 34F INDIAN HILLS
MTN CENTER., CA 92361
Phone... 1-800-262-9966
Signed : 0%
(date)
Name....
Company.
Address.
Phone...
Signed
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone
Signed
(date)
WATER HEATING Page 1 DHW
-------------- ------------------------------------------
---------------------------------------------
Project Title.......... PACIFIC Date. 01/07/92
Project Address....... LA QUINTA-----------------.----
Documentation Author... W J FINNELL
Company ................ ENERGY CONSULTING GROUP
Telephone.............. 1-800-262-9966
Building Permit #
Plan Check / Date
Compliance Method....... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15 __-_________
----------------------------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -WATER HEATING '
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
-------------------------------------------------------------------------------
WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC
A. EQUIPMENT DATA
-----------------
1. Water heater type.......
2. Manufacturer............
3. Model number............
4. Ignition device.........
5. Tank volume .............
6. Recovery efficiency......
7. Standby loss.............
8.. Rated Input..............
9. Number of Heaters.......
10.Insulation Jacket........
Storage, Electric
WATERMISER 40FESL .
n/a
37 gal
.99 percent x 0'.01
.0082 percent/hour x 0.01
15358.5 Btu/hr
1
No
B. OPERATING DATA
-----------------
1. Climate Zone............
2. Water heating budget....
3. Tank set temp...........
4. Water main temp.........
5. Daily hot water load....
6. Ambient air temp........
7. Adj. Standby Losses.....
8. No. dwelling units......
9. Pump power ..............
10 -Pumping energy..
15
18700
140 F
70 F
50 gal
72.6 F
.0082
1
kBtu/yr/unit
0 Watts (0 Watts controller)
0 Watt-hr/yr' (24 hr per day)
C. WATER HEATING ENERGY CREDITS
-------------------------------
1. Credit Name... ......... Recovery
2. Annual savings.......... 2805 kBtu/yr/unit..
D. ANNUAL WATER HEATING ENERGY
------------------------------
1. Recovery load........... 10539 kBtu/yr
2. Recovery energy ......... 7813 kStu/yr
3. Standby loss energy..... 1392 kBtu/yr
4. Pumping energy.......... O kStu/yr source
5. Total energy............ 27614 ketu/yr/unit source
6. Comparison .............. -8914 k8tu/yr/unit source
7. Points .......... -14
8. Water Heating.Energy Use 21.97 kBtu/yr/sf
(D5 x 88) / 1257' sf '
HVAC SIZING Page 1 HVAC
Project Title. PACIFIC Date. 01/07/92
Project Address........ LA QUINTA ______ ___________
Documentation Author... W J FINNELL
Company ................ ENERGY CONSULTING GROUP
Telephone .............. 1-800-262-9966
Building Permit #
Plan Check / Date
Compliance Method...... MICROPAS3 by E.nercomp, Ince. ; Field Check/ Date '
Climate Zone........... 1.5 ---------------------
------------------------------------------------ _
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -HVAC SIZING '
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC
------------------------------------------------------------------------------
GENERAL INFORMATION
_
Floor Area..............1257 sf
Volume ..................... 10936 cf
Front Orientation........... Front Facing 90 deg (E).
Sizing Location INDIO
Latitude ................... 33.7 degrees
Winter Outside Design....... 29 F
Winter Inside Design....... 70 F
Summer Outside Design....... 112 F
Summer Inside Design........ 78 F
Summer Range............... 30 F
Shading.Used................. No
Latent Load Fraction........ 0.20
HEATING AND COOLING -LOAD SUMMARY
Heating Cooling
Description ( Btuh ) ( Btuh )
Opaque.Conduction and Solar...... 8687 4249
Glazing.Conduction.............,,, 3624 3006
Glazing Solar....... n/a 5130
Infiltration............. ...... 6449 3822
Internal Gain...... .. n/a 2550
Ducts.... ... .......--.. 1876 1876
Sensible Load.......... 20636 20631
Latent Load... ..................... n/a 4126
Total Load 20636 24758
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output applicable for gas central furnaces only
MANDATORY -MEASURES CHECKLIST: RESIDENTIAL Page l MF -1R
Project Title.......... PACIFIC
Date.. .. .. 01/07/92
Project Address........ LA QUINTA
Documentation Author... W J FINNELL ;Building Permit #
Company ................ ENERGY CONSULTING GROUP
Telephone .............. 1-800-262-9966 ; Plan Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inc. ;Field Check/ Date
Climate Zone............ 15 ---------------------
MICROPAS3 v3.1.1 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
-------------------------------------------------------------------------------
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the -Certificate -of Compliance. When this checklist is incorporated into the
Permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Design,- Enforce-
er ment
* 2-5352(a): Minimum ceiling insulation R -19 -Weighted average.
2-5352(b): Loose fill insulation manufacturers labeled R -Value.
* 2-5352(c): Minimum wall insulation in framed walls R-11
weighted average (does not apply to exterior mass walls).
2-5352(k): Slab edge insulation, -.water absorption rate no
greater than 0.30, water vapor transmission rate no
greater than 2.0 perm/inch.
-2-5311: Insulation specified or installed meets CEC quality
standards. Indicate type and form.
2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16.
2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped; all joints and
Penetrations caulked and sealed.
2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
2-5352(d): Installation of Fireplaces
1. Masonry and factory -built fireplaces have:
a. Tight fitting, closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper.and control
2'. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
-------------------------------------------
Project Title.......... PACIFIC Date....:... 01/07/92
------------------------------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC '
-------------------------------------------------------------- ----- -----
HVAC AND PLUMBING SYSTEM MEASURES
---------------------------------
2-5352(g) and 2-5303: Space conditioning equipment sizing.:
attach calculations.
2-5352(h) and 2-5315: Setback thermostat on all applicable
heating systems.
* 2-5316(a).: Ducts constructed', installed and insulated per
Chapter 10, 1976 UMC.
2-5316(b): Exhaust systems have -damper controls.
2-5314(c): Gas-fired space heating equipment, has
intermittent ignition devices.
2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.
Design- Enforce-
er meet
2-5352(i): Water heater insulation blanket (R-12 or greater) for
storage and backup tanks for solar water heating systems (first
5 feet of pipes closest to tank.insulated to R-3 or greater).
2-5312(Exception I): Pipe insulation on steam and steam
condensate return and recirculating piping.
2-5318(d): Swimming Pool Heating
1. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater..
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
5. Directional water inlet.
LIGHTING AND APPLIANCE.MEASURES
-------------------------
2-5352(j): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
Design- Enforce-
er meet
2-5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp ballasts certified by 'the CEC.