Loading...
BSOL2015-011752224 Avenida Madero BSOL2015-0117 Cv r., 4. 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO,CA 94402 y 4 laQuiKro COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2015-0117 52224 AVENIDA MADERO 773242001 10.3kW PV SYSTEM - (39) 265W PANELS/(2) INVERTER $22,840.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I a'tensed der provisions of Chapter 9 {commencing with Section 70001 of Div' oft a Bus e s and Professions Code, and my License is in full force and effe . License ass: C 6 8 C10 A Lic rise N 1 4 Dat Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from a Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of. the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/11/2015 Owner: NANCY FLOREK 52224 AVENIDA MADERO LA QUINTA, CA 92253 Contractor: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO,CA 94402 (650)963-5630 Llc. No.: 888104 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compeVQ6qn, as provided for by Section 3700 of the labor Code, for the performance W"of r which this permit is issued. ve and will maintain workers' compensation insurance, as required by the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree t t, if I o d becom bject to the workers' c . pensa on provisions of Sect' n 37 f the abor C de, shall forthwith co m t tose ro issiiioonJ/s. Date: - ✓ Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVECELABOR WFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND VII TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OCODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state t the ab information is correct. I agree to comply with all city and county ordin ces d s to I ws r at g to building construction and hereby authorize representa veAt): 't en r up n the above mentio ed operty or inspection purposes. Date: ignature (Applicant or A Ai c FINANCIAL •1, s J DESCRIPTION >kr' ACCOUNT ;:. ' u`QTY AMOUNT; ' PAID r PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 ti $0.00 - PAID; BY u - : METHOD •" F ` " , .RECEIPT # CHECK # ; . CLTD BY, Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY a AMOUNT.:;, PAID :PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY -: 'METHOD `' :' RECEIPT # CHECK # CLTD BY DESCRIP,TION.. 1''ACC6.UNT '. _ :QTY . ; ,+ AMOUNT. ° :: PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY " `. METHOD ` RECEIPT# CHECK #.,- ' ." CLTD BY Total Paid for ELECTRICAL: $48.34 - $0.00 .DESCRIPTION ' " ..... .. •. 'a.: ` • R .'' < ACCOUNT . ti'..'' ,QTY,; ' ' AMOUNT ?•-` .. . PAID ` :PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 a PAID BY - " ^ sMETHOD . ', RECEIPT,# r CHECK # _ CLTD. BY-, Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• •• _o ,may` z • y -. , © r .. ` 7 !i : - c 'OF.7'th'v ' ..'. ' ` w a7. ;- }1a .r z.—. :'1•S .,+ V 6 } r . Gs `G xf _ , }+ 3 •. .'_ ..: - . r is i+. ...= ` t,. t`. • .ts"' :.,". S Ycr.;,..y •°rs_. r v.+: .. .' ' y K rl.."":.y4"t+. ' +' +__ h.r "' s: ':..4«.•, r_ s"'• . .. r :r I APPIied to Approved ' -- n Description: 10.3kW PV SYSTEM - (39) 265W PANELS/(2) INVERTER Type: SOLAR. Subtype: Status: APPROVED Applied: 7/30/2015 PJU Parcel No 773242001 Site Address: 52224 AVENIDA MADERO LA QUINTA,CA 92253 Approved: 8/10/2015 LUR Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 41 Lot: 1 - Issued: UNIT 3 Lot Sc Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $22,840.00 Occupancy Type: ' . Construction Type: Expired: ' No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 10.3kW SOLAR ARRAY - (39) 265W KYOCERA PANELS W/ (2) ABB PVI-3.6=OUTD-US-Z-A-AFCI INVERTERS [6915 cessummary qip.: y. ,. •`-1 ..5,;. F] 2013 CALIFORNIA ELECTRICAL CODE. _ - I APPIied to Approved ' -- n Description: 10.3kW PV SYSTEM - (39) 265W PANELS/(2) INVERTER Type: SOLAR. Subtype: Status: APPROVED Applied: 7/30/2015 PJU Parcel No 773242001 Site Address: 52224 AVENIDA MADERO LA QUINTA,CA 92253 Approved: 8/10/2015 LUR Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 41 Lot: 1 - Issued: UNIT 3 Lot Sc Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $22,840.00 Occupancy Type: ' . Construction Type: Expired: ' No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 10.3kW SOLAR ARRAY - (39) 265W KYOCERA PANELS W/ (2) ABB PVI-3.6=OUTD-US-Z-A-AFCI INVERTERS [6915 cessummary I APPIied to Approved ' -- n Description: 10.3kW PV SYSTEM - (39) 265W PANELS/(2) INVERTER Type: SOLAR. Subtype: Status: APPROVED Applied: 7/30/2015 PJU Parcel No 773242001 Site Address: 52224 AVENIDA MADERO LA QUINTA,CA 92253 Approved: 8/10/2015 LUR Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 41 Lot: 1 - Issued: UNIT 3 Lot Sc Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $22,840.00 Occupancy Type: ' . Construction Type: Expired: ' No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 10.3kW SOLAR ARRAY - (39) 265W KYOCERA PANELS W/ (2) ABB PVI-3.6=OUTD-US-Z-A-AFCI INVERTERS [6915 qip.: y. ,. •`-1 ..5,;. yt1*TTrm'STAFF NAME; ACTION DATE COMPLETIONDATE' ,NOTES,} _­ 7­7 LUIS URIBE 8/10/2015 8/10/2015 SENT ELENA AN EMAIL. PERMIT IS READY TO BE ISSUED. , PLAN CHECK SUBMITTAL PHILIP JUAREZ 7/30/2015 7/30/2015 RECEIVED ta .. ;'.t/'- 'A'4'L.a _ -0fp]a Jr`y,n `.i`a'a, 9s'; 1 ? !,4. ' .1:f9" t!. L'If: /:4,.} Z:.#{ •n '.y. .: , •. t .,,;4 ,,)) f t` •:y' .a7 j ME 1211ka r °ADDRESS1' CITY •STATE.;ZIP ..PHONE,,FAX, .'EMAILT 7.7NA METiPf_ zNAME SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (773)242-0010 mplasse@solarcity.com CONTRACTOR SOLARCITY CORPORATION ` 3055 CLEARVIEW WAY SAN MATEO CA 94402 (773)242-0010 mplasse@solarcity.com OWNER NANCY FLOREK 52224 AVENIDA LA QUINTA CA 92253 (773)242-0010 MADERO DESCRIPTION +:w - "ACCOUNT Q 'AMOUNT PAID ;PAID DAT E' .RECEIPT,# . CHECK #.' METHOD . ; 7 -, r PAID BY C f , — tBSAS S61473 FEE 101-0000-20306 0 $1.00 • $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 - r BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM -ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid forELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 - 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91:85 $0.00 TOTALS:00 PARENT PROJECTS ::::A "I 1WK BOND INFO RMATION ATTACHMENTS v . J - Printed: Tuesday, August 11, 2015 4:42:11 PM 2 of 2 C z SYSTEMS Bfn. # City of La Quints \ Bonding 8z Safety Division P.O Box 1504, 78-495 Caffe Tampico La.Quhlta, CA 92253 - (760) 777-7012 . Building Permit -Application and Tracking Sheet Pennit #D ProjectAddress Owne's Name: IL NON A. P. Number.. Address• e a IVMM Legal Description: City. ST, Zip: La Quinta, CA Coubwtor. Solar City Telephon : Address: 3055 Clearview Way. PmjectDescripflon: grobf mounted solar panels . city, sr, Tp: San Mateo; CA, 9440.2 % inverters D • w Telephone. 650-638-1028 state Lit. # : 888104 cry Lie ; Arch., Engr•. Designer Address: Qly' ST. Zip: Telephone: Construction Type:. Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Sq. FL: #Stories` #Units: Name OfconawtPerson:Elena Loya Telephone # of c ontactPerson: (442.)256-1134 Estimated Value of Project: 1127i;5 - 'APPLICANT: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACICYIVG PERMIT FEFS Plan Sets Plan Cheek submitted ftem Amount Stmetuial Cala. Reviewed, ready for corrections Plan Check Deposit. . Truss Cala. Called Contact Person Plan Cheek Balance Title TA Cates. Plans picked up Construction Flood plain plan Pians resubmitted.. Mechaww Grading plan Z'! Review, ready for correctious/issue Electrical Subeoutaetor Ilst Called Contact Person Plnnrblug Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSBr 1i° Review, ready for correetionslissue Developer Impact Fee Planning Approval- Called Contact Person A IB.P. Pub. Wks. Appr,' Date of permit Issue School Fees Total Permit Fees t Rte. .+ y • , ` ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES ` 3' r A' AMPERE_. • > • 1. THIS SYSTEM IS GRID=INTERTIED VIA A ALL CONSTRUCTION SHALL'COMPLY WITH THE 2013 ' AC• , ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) "- EXISTING 4. WHERE ALL TERMINALSOF..THE DISCONNECTING, C' r- • ' F• EMT, -ELECTRICAL METALLIC TUBING i . MEANS MAY BE ENERGIZED IN THE OPEN -POSITION, , ' ; x TY OFLAQU'NTA ` FSB. FIRE SET—BACK - A SIGN WILL BE PROVIDED WARNING OF THE I' r t - - `' BUILDING & SAFETy pEpr i - GALV• GALVANIZED '' HAZARDS PER ART. 690.17. `' -. A _ GEC. {GROUNDING ELECTRODE CONDUCTOR "" 5. EACH •UNGROUNDED CONDUCTOR OF THE APPROVED'" f , = R CONS GND 'GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY - - . HDG..HOT.DIPPED GALVANIZED,..- _ PHASE AND SYSTEM PER ART. 210.5.; - xR ,- , L , DATE o , I CURRENT _''" _ 6. CIRCUITS OVER 250V TO GROUND SHALL } s ® •l a - Imp'- CURRENT -AT MAX,POWER . - COMPLY WITH ART. 250.97, 250.92(B). _ r - a:' _ BY Isc SHORT ,CIRCUIT CURRENT Y' F ` 7. DC CONDUCTORS EITHER DO NOT ENTER y / kVA' KILOVOLT,_ AMPERE' Y ". "' >' BUILDING OR ARE RUN IN METALLIC RACEWAYS OR .+ kW: -KILOWATT >; •? =Y ' '; ENCLOSURES TO THE FIRST ACCESSIBLE DC • - LBW -LOAD BEARING WALL- - G r DISCONNECTING -MEANS PER ART. 690.31(E). MIN MINIMUM .. .t 8. ALL WIRES SHALL BE PROVIDED WITHi STRAIN . -_ .= —NEW t • r +: - ' - RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY T • ':. NEUV NEUTRAL 3 `- .•- UL LISTING. `s •: Y s. NTS_ • 'NOT TO SCALE i • 9. MODULE FRAMES SHALL BE 'GROUNDED AT THE - OC': ON CENTER UL—LISTED LOCATION - PROVIDED BY THE' asp PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING - I ;;' i`.tt POI POINT OF INTERCONNECTION ,y .'' F . HARDWARE.- *: PV PHOTOVOLTAIC 10. MODULE .FRAMES, RAIL, AND POSTS , SHALL BE ; SCH SCHEDULE - Z.. BONDED WITH EQUIPMENT, GROUND, CONDUCTORS. . S STAINLESS STEEL ` STC" STANDARD TESTING CONDITIONS tr TYP TYPICAL1. " :• ; UPS UNINTERRUPTIBLE POWER SUPPLY yrs .: - IU0 `L.Ji zi V VOLT ` Vmp VOLTAGE AT MAX POWER VICINITY MAP - Iu'n t / Voc VOLTAGE AT OPEN CIRCUIT " .3 -•.yt C f INDEX W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN _PV3 STRUCTURAL VIE *4, [UPLIFT LINE DIAGRAM CALCULATIONS LICENSE GENERAL NOTES PV5 PV6 ELECTRICAL CALCULATIONS - LINE CA 1. ALL WORK TO BE DONE' TO THE 2013 # 888104 Cus hee sGALE ttached C=10 CALIFORNIA BUILDING CODE AND THE 2013_ CALIFORNIA RESIDENTIAL CODE. - 2. ALL ELECTRICAL WORK SHALL COMPLY WITH + n THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY ' THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: • ZEP SOLAR I REV BY DATE COMMENTS ' AHJ: La Quints- - • ► — + REV A NAME DATE COMMENTS ' UTILITY: Imperial Irrigation District O ♦ ' >t - ' ee• 1F 1 e - ®" - - - CONFIDENTIAL =. THE INFORMATION HEREIN JOB NUMBER: JB -9224096 0 0 PREMISE OWNIR DESCRIPTION: DESEric \\` CONTAINED SHALL NOT BE USED FOR THE FLOREK, NANCY FLOREK RESIDENCE Eric smith ."to c I C' s NO SHTOF ALL IT BENDISCLOOSSED N WHOLE ORT SOLARCITY CIN M01N1NG it ZEP ZS Tile WTile 52224 AVENIDA MADERO '' 10.335 KW PV ARRAY - Ii. 0 of 1ty TO OTHERS T'SWITH THE RECCONNECTION MODULES LA QUINTA CA 92253 ' ORGPAR ORGANIZATION, IXCEPT IN CONNECTION WITH EXCEPT IN THE SALE AND USE OF THE RESPECTIVE (39) KYOCERA # KU2656ZPA APN. * 3os5 gearvieN Way San Mateo, CA 94402 SHEET: REk DATE - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER: ABB PVI-3a—ounTD—s-us-z—A pABE N, 773242001 COVER SHEET : `. PV 1 .7/29/2015 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) rnwsdoraHyaam a' s a w Fo Q c 0 KVA1j PHAS ,HIGH"' KV LOW 120/241 :R# 1 BAS -103107 OSED BI-DIRECTIONAL 4 „ *DISCONNECT -BRAND -MODEL - AC ,DISCONNECT 13FBd9BfBI I'MAIN PANEL PVI-3.6-OUTD-S-US-Z-A 2O0A, 240V, SINGLE PHASE, 2 WIRES, 22kAiC EXISTING BI DIRECTIONAL METER# 1BAS-103107 PREMISE OWNER: FLOREK, NANCY 52224 AVENIDA MADERO LA QUINTA, CA 92253 7607777238 FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NNE- SITE AMESITE PLAN PITCH: 20 ARRAY PITCH: 2O MPI AZIMUTH: 360 ARRAY AZIMUTH: 360 MATERIAL: Low Profile W -Tile STORY: 1 Si PITCH: 20 ARRAY PITCH: 20 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 Si I FC;FNn Q (E) UTILITY METER & WARNING LABEL Ing INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS -*w- CONDUIT RUN ON EXTERIOR - CONDUIT RUN ON INTERIOR GATE/FENCE. Q HEAT PRODUCING VENTS ARE RED r, _ 1% ;1 INTERIOR EQUIPMENT IS DASHED L_J SITE PLAN N Scale: 3/32" = 1' 01, 10' 21' Eric Smith SHEET: REV: DATE:- PV ATEPV 2 7/29/2015 W E S A-ij e A';SolarCity 3055 Cleorvlew Way San Moteo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 (888)—SOL—CITY (765-2469) www.solarcitycom , .dam. } CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9224096 0 0 y CONTAINED SHALL NOT BE USED FOR THE MOUNTING SYSTEM: g y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTile PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES (39) KYOCERA # KU2656ZPA- ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. PERMISSION OF SOLARCITY INC ABB W PVI-3.6-OUTD-S-US-Z-A PREMISE OWNER: FLOREK, NANCY 52224 AVENIDA MADERO LA QUINTA, CA 92253 7607777238 FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NNE- SITE AMESITE PLAN PITCH: 20 ARRAY PITCH: 2O MPI AZIMUTH: 360 ARRAY AZIMUTH: 360 MATERIAL: Low Profile W -Tile STORY: 1 Si PITCH: 20 ARRAY PITCH: 20 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 Si I FC;FNn Q (E) UTILITY METER & WARNING LABEL Ing INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS -*w- CONDUIT RUN ON EXTERIOR - CONDUIT RUN ON INTERIOR GATE/FENCE. Q HEAT PRODUCING VENTS ARE RED r, _ 1% ;1 INTERIOR EQUIPMENT IS DASHED L_J SITE PLAN N Scale: 3/32" = 1' 01, 10' 21' Eric Smith SHEET: REV: DATE:- PV ATEPV 2 7/29/2015 W E S A-ij e A';SolarCity 3055 Cleorvlew Way San Moteo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 (888)—SOL—CITY (765-2469) www.solarcitycom , a MP2 ' X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" a PORTRAIT 48"- 19" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 180 PITCH 20 STORIES: 1 ARRAY AZI 180 PITCH 20 Low Profile W -Tile A SIDE VIEW OF MPI NTS MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 19" TOP CHORD 2X4 @, 24" OC ROOF AZI 360 PITCH 20 STORIES: 1 ARRAY AZI 360 PITCH 20 BOT CHORD 2X4 @24" OC Low Profile W -Tile , FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS Eric Smith 'IQ N.,solarCit . 3D55 ClearWew Way SHEET: REV. DATE San Mateo, CA 94402 L•(650) 638-1028 F:(650) 638-1029 PV 3 7/29/2015 1 (888) -SOL -CITY (765-2489) www.sWarcity.com F. • a A SIDE VIEW OF MPI NTS MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 19" TOP CHORD 2X4 @, 24" OC ROOF AZI 360 PITCH 20 STORIES: 1 ARRAY AZI 360 PITCH 20 BOT CHORD 2X4 @24" OC Low Profile W -Tile , FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS Eric Smith 'IQ N.,solarCit . 3D55 ClearWew Way SHEET: REV. DATE San Mateo, CA 94402 L•(650) 638-1028 F:(650) 638-1029 PV 3 7/29/2015 1 (888) -SOL -CITY (765-2489) www.sWarcity.com -t' INSTALLATION ORDER - " DIA THREADED STUD ', REMOVE TILE, LOCATE & MARK Y & NUT (1) RAFTER LOCATION.PLACE STANDOFF • BASE &DRILL PILOT HOLES. '- ' ZEP LEVELING FOOT _______ _______ ____________ ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT -HOLE. ZEP ANTI—ROTATION PLATE (6) ' M10 BOLTS SEAL PILOT HOLES AND BOTTOM OF MOUNTING BASE 5) ((3) STANDOFF WITH POLYURETHANE (E) TILE - SEALANT. (E) ROOF DECKING 4) LAG STANDOFF BASE INTO RAFTER. (E) RAFTER (4) (2) " DIA STAINLESS (3) 5) PLACE FLASHING AND ATTACH F`a" STEEL LAG BOLT (2—j" SEALING SPACER WITH SINGLE BOLT. EMBED, MIN) PLACE ZEP BAR. THEN INSTALL ((6) LEVELING FOOT WITH BOLT & WASHER. 1 STANDOFF _ ' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9224096 . 0 0 PREMISE OWNER - FLOREK, NANCY MOUNTING SYSTEM: ZEP ZS Tile WTile Til BENEFIT OF NOR SHALL IT BENE EXCEPT DISCLOSED IN ORaTY CIN 52224 AVENIDA MADERO PART TO OTHERS OUTSIDE -THE RECIPIENT'S LA QUINTA, CA 92253 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (39) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. - C Q 7607777238 INVERTER: ABB PVI-3.6—OUTD—S—US—Z—A A SIDE VIEW OF MPI NTS MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 19" TOP CHORD 2X4 @, 24" OC ROOF AZI 360 PITCH 20 STORIES: 1 ARRAY AZI 360 PITCH 20 BOT CHORD 2X4 @24" OC Low Profile W -Tile , FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS Eric Smith 'IQ N.,solarCit . 3D55 ClearWew Way SHEET: REV. DATE San Mateo, CA 94402 L•(650) 638-1028 F:(650) 638-1029 PV 3 7/29/2015 1 (888) -SOL -CITY (765-2489) www.sWarcity.com t UPLIFT CALCULATIONS 07.29.2015 PV System Structural Version #48.9. o ;,s. SolarClt Desion Software Project Information & Table Of Contents Risk Category: PVSystern Type Spanish The Roof `\,?! II BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR IT BE DISCLOSED IN MMOLE OR IN 52224 AVENIDA MADERO 10.335 KW PV ARRAY SolarC itySleekM&unt— Spanish Tile Roof MALL ZEP ZS Tile Wile es oof Com Roofin PART TO OTHERS OUTSIDE THE RECIPIENTS Roof Slope LA QUINTA CA 92253 200 RaafterS acin 244 C: (39) KYOCERA # KU2656ZPA PV System Module Orientation PVModu_le Area PV Module. Width PV; Module Length Standoff Attachment Hardware Landscape and Portrait SHEEP: REV. DATE wvERrE ABB PVI-3.6—OUTD—S—US—Z—A 691 sf_ 7607777238 UPLIFT CALCULATIONS PV 4 7/29/2015 39" 65" SM Tile Reduced Ground/Roof Live/Snow Loads Ground Snow Load _Su-_rrounding Roof Snow. Roof Snow Over PV Modules 0.0 psf ASCE Table 7-1 { 0.O,psf ASCE Eq: 7.4-1 0.0 Psf Wind Design Criteria. Wind Desrga Code_ Wind Design Method. Basic Wind Speed ASCE 7-10 Par_do(yy/Fully En'dosed M Wod 110 mph V Fig.26.5-1A =Sedion 26;7 rag. 30.4-2n/e/esA/a Exposure Category RoofStyle C Gable Roof —"_. Mean:Roof;Helght Effective Wind Area 1 Module '—'— 15 ft Sediorr 26:2 IBC 1509.7.1 A 17.7 sf ' Wind Pressure Catculation,Coefficients_ Wind Pressure Exposure Topographlc FFac#or Wind Directlonality Factor- r Kz 0.85 Table 30-3-1— wSedlon:2b:8' _. Section 26.6-1_ KiC 1:OU _ Kd 0.85 Im ortance Fado'r I NA Velocity Pressure qh qh. = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Ext. Pressure Coeffident (Up) Ext Pressure Coefficient Down G(p (Up), G Down -0:8_8 ag. 30.4-2A/0/c-sA/e 0.45 5D.30:4-2A/81c-5A/8 Design Wind Pressure P I p = gh GC Equation 30.4-1 Wind Pressure 1p I Wind Pressure Down —P(up)_ -19.6psf down 16.0 Psf Allowable Standoff Spadings X -Direction .Y -Direction Max Allowable Standoff Spacing— Max Allowable_C_antileyer Standoff Confi uration Landscape 48" 39" =n: scape Landscape Not-Sta gered MayStandoff TributaryArea PV Assembly Dead Load NetWind Uplift at Stand'o_ff _Uplift Capacityyof Standoff Standoff Demand Ca a Trio, W -PV 13 si 3 psf T_adual" 141 lbs 446 Itis T -allow DCR. -29.3°x6 Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable,Cantil_eyer Standoff Confi uration _ Portn it_ 19" NA, Portrait Not -Staggered Max,Standoff Tributary Area PV Assembly Dead Load Net Wind Uplift_at Standoff Uplift Capacity of Standoff Standoff Demand Ca a —T -Ob— . 22 sf, W-pV 3 psf Tya¢ual -219,1bs T -allow 446 lbs DCR 49.1% CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER J B-9 2 2 409 6 0 0 PREMISE D"HQt DESCPoPTION: FLOREK, NANCY FLOREK RESIDENCE DESIGN: EPIC Smith `\,?! MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR IT BE DISCLOSED IN MMOLE OR IN 52224 AVENIDA MADERO 10.335 KW PV ARRAY X01 1 Solar t\ MALL ZEP ZS Tile Wile PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA CA 92253 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (39) KYOCERA # KU2656ZPA PAGE HAMS 3D55 ClearMew Way San Mateo, CA 94402 SHEEP: REV. DATE wvERrE ABB PVI-3.6—OUTD—S—US—Z—A PERMISSION OF SOLLAARTgTTY INOCT THE WRITTEN 7607777238 UPLIFT CALCULATIONS PV 4 7/29/2015 (B88j T.(650)(1765-2 j 1cityaom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES Drub, e . Eric Smith INVERTER SPECS M01N¶"G i ZEP ZS Tile WTile MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number: WMB202040B Inv 1: DC Ungrounded INV 1 -(')ABB 1 PVI-3.6-OUTD-S-US-Z-A A - (39)KYOCERA # KU2656ZPA CA # 888104 _WITH IRREVERSIBLE CRIMP Meter Number:1BAS-103107 --Inv 2: DC Ungrounded FCl Inverter, Zigbee 360OW, 24OV, s _ PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, io Backbar C-10 Underground Service Entrance INV 2 -(1)ABB 0 PVI-3.6-OUTD-S-US-Z-AB FCI Inverter, Zigbee 360OW, 24OV, sem` Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A CENTER -FED MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity CUTLER -HAMMER BRYANT 125A Load Center Inverter 1 IND 6 a 1 200A/2P Disconnect II(N) 9 ABB Dc. Vstart - 120V PVI=3.6-OUTD-S-US-Z-A Da MP 1: 1x11 (E) LOADS B' C 20A/2P Ll . zaov r---------- ----------- _ EGc ---------------------------- • . I DG I • - 40A/2P ;ND - -1 - N - DG I - - -- -- .._EGG _ _ _ DC+ 5 2 Vstart = 120V DC« _ _ _ _ .. 9 I z i------------------- - ••_.- GEC DG N G MP 2: 1x9 } EGC GND ------------- ------------- GC ----j --- ----- --------------- J `1 A I • ADJUST MIN. ACTIVATION VOLTAGES. (1)Conduit Kit; 3/4' EMT N Inverter 2 IND EGCIGEC_ J - - - I I - lO --.): - ABB PVI-3.6-OUTD-S-US-Z-A 8 s DC« VStart = 120V DP MP 2: 1x8 20A 2P Gec---♦ z vr---------- — --------- - -EGc - - - - - - - - - - - ----- --- I DC« TO 120/240V SINGLE PHASE I UTILITY SERVICEI " - - ---------------------------- I - ` -. -N DC-vstart EGG ` _ DC« GEC -- N Dc 7 4 Dc« = 120v c- MP 1: 1x11 s EGC--- G IGND --- --- - -- --- --- ---- - - --- -- -- -- ------- ---- - ----J - - - I _ (1) Conduit Kit; 3/4* EMT n XITYrOF L!1 XUIIn'Y 1Te !l -BUILDING & SAFETY DEPT, ;• PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE r ''APPROVED APPROvE PERMITTED BY'SEPARATE COLOR CODING, MARKING TAPE, TAGGING; OR OTHER APPROVED MEANS. THE MEANS OF *' . FOR CONSTRUCTION GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. _ _ ' - • DATE l . BY * . PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL - ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE - Voc* = MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS poI (1)CUTLER-HAMM # BR240 PV BACKFEED BREAKER Breaker, 40A 2P, 2 Spaces B (1)CUTLER-HAMMER 1 DG222URB Disconnect; 60A. 240Vac, Non -Fusible, NEMA 3R AC A (1)So15City N 4 STRING JUNCTION BOX 2x2 STRINGS, UNFUSED, GROUNDED DC - (1)CUTLER -LtAMMER DG100NB Ground eutral it; 60-100A, General Duty (DG) C(I)BRYANT 1 BR481.125RP ` Load Center, 125A, 120/24OV, NEMA 3R - (2) UTLEBrea-H 2OA P8 2 RSpaces 1 AWG jB, THWN-2, Blade © (1)AWG #B, THWN-2, Red 1 AWG j10, 1HYN-2 Blade O (1)AWG 110, THWN-2, Red 1 AWG /10, THWN-2 adk Voc 388.13 VDC O (1)AWG 010. THWN-2, Red Vmp = 279 VDC Isc - 9.26 ADC Imp= 8.55 ADC O 2 AWG 110, PV Wre, 600V, Block Voc = 474.38VDC Isc = 9.26 ADC (1) AWG 110, Solid Bare Copper EGC Vmp = 341 VDC Imp= 8.55 ADC L (1)AWG a THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC - (1)AWG,18, : H11N-2, Green .. EGC/GEC - (1.)Conduit,Kit; 3/4', EMT ......... (1)AWG 110, THWN-2, White ... . . . -S 1)AWG.18, THWN-2, Green .. (1) AWG 110, 1HWN-2, Black NEUTRAL Vmp =240 VAC Imp=16 AAC EGC/GEC ,- (1.)Conduit,Kit; 3/47, EMT ..... , . LLL LLL 1)AWG 11 P.. TH.WN-2,. Green.. EGC ................................ (1)AWG 110' THWN-2, Block Voc* = 474.38 VDC © (1) AWG 110, THWN-2, Red Vmp = 341 VDC Isc = 9.26 ADC Imp= 8.55 ADC— ........ ODC ......... (2) AWG 110, PV Wire, 600V, Blade Voc* = 388.13 VDC Isc -=-9-.2-6 ADC ( 1 ) AWG 110, Solid Bare Copper EGC Vmp = 279 VDC Imp= 8.55 ADC (1) AWG 110, THWN-2, Red ® S1) AWG,110,, TFtWtJ-2,. Green, EGC JJJ (1)AWG 110, THWN-2, White (1.)AWG.18, THWN-2, Green NEUTRAL Vmp =240 VAC Imp=16 AAC EGC/GEC,-(1,)Conduit,Klt; 3/4'. EMT ...... (1)AWG 110, THWIN-2, Block Voc* = 474.38VDC O (1)AWG 110, THWN-2, Red Vmp =341 VDC Isc = 9.26 A IMP= 8.55 ADC .. O ... . . (2)AWG 110, PV Wrae, 600V, Block Voc* = 345.01 VDC Isc = 9.26 ADC (1)AWG 110. Solid Bare Copper EGC Vmp =248 VDC IMP= 8.55 ADC . , . , . _ .. , , , .. , , _ , 111::100 1) AWG, j10., TFiYkTl-2,, Oem EGC ® 1)AWG 110, THWN-2, Black Voc* = 345.01 VDC (1)AWG 110, THWN-2, Red Vmp = 248 VDC Isc = 9.26 ADC Imp= 8.55 ADC ® EJ (2)AWG 110, PV Wve, '6'00V, Black Voc* = 474.. VDC Isc = 9.26 ADC (1) AWG 110, Solid Bare Copper EGC Vmp = 341 VDC Imp= 8.55 ADC (1)AWG 010, THWN-Z Green EGC CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT EXCEPT USED RC THE NOR SHTOF ALL ITNYONE BEE DISCLOSED IN WHOLE ORITY CIN PART OTHERS THE RECIPIENTS PT IN IN CONNECTION WITH ORGANIZATION, EXCEPT THE SALE AND USE OF. THE RESPECTIVE PERRMISSIONCITYEPMENTOFISOLARCITY INOIC..T,7HE WRITTEN JOB NUMBER: J B- 9224096 0 0 rnmbi, arK utZAnr IIDN: FLOREK, NANCY FLOREK RESIDENCE 52224 AVENIDA MADERO 10.335 KW PV ARRAY LA QUINTA CA 92253 , PAGE NAME: 7607777238 THREE LINE DIAGRAM Drub, e . Eric Smith '! „ Olar ' wo, M01N¶"G i ZEP ZS Tile WTile MODULES: (39) KYOCERA # KU2656ZPA 3os5 6e e. Way San Mateo, CA 94402 (888)(500,678 1028 4:(650).38-1029 iy.eom REv ppb PV 5 7 29 2015 / / INVERTER ABB PVI-3.6-OUTD-S-US-Z-A ELECTRICAL CALCULATIONS (`' ' / Q v NTA OF O r DEPT.{ ,'CITY ( A I BUILDING 8, SAF`E,E® AP O V FO CO TRUCTION -DATE 0JOBYAmpacity - -' Module: Inverter 1: Module: Inverter 2: Module: Inverter 3: Module: 20 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Vdrop =(Imp) 2 Len th Resistance / mp) Im A Max. Length ft IWire String: 8.55 20 1 AWG #10 at Max Ave Hi: 109 deg F Vdrop = 8.55 40 0.00124 Ohms / 208.94 0.2 Branch: 8.55 50 AWG #10 at Max Ave Hi: 109 deg F Vdrop = (8.55 100 0.00124 Ohms) / 248 0.51 Total voltage dro in DC conductors = 0.71 Inverter: 16 10 1 AWG #10 at 240V Vdrop = 16 20 0.00124 Ohms / 240 V 0.09 Combinedl 25.6 15 1 AWG #8 at 240V Vdrop = 25.6 30 0.00078 Ohms) / 240 V 0.17 Total voltage drop in AC conductors = 0.25 Total voltage drop in AC and DC conductors = 0 1 ABB PVI -3.6-S AFCI 0.96 3840 4571.52 19 Kyocera 265W 1000V L38.1 1 ABB PVI -3.6-S AFCI 0.96 3840 4342.94 Kyocera 265W 1000V 238.1 Kyocera 265W 1000V 238.1 Inverter 4: Total: 39 Modules Total Inv Pwr: 7680 18914.46 PTC Photovoltaic Module Electrical Specifications: Total STC:j 10335 Voc: 38.3 V deg F deg C Vmp: 31 V Record Low Temp: 14 -10 Isc: 9.26 A Max Average Hi Temp: 109 43 Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisc:I 5.56 1 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Voc Correction Factor: ABB PVI -3.6-5 AFCI Inverter Min Vdc Input: 8 Kyocera 265W 1000V Voc= 306.4 Min Vmp at Max Temp: Max Voc at Min Temp: Vmp= 248 Inverter Max Vdc Input: Isc= 9.26 Imp= 8.55 Max String Size: Icont= 11.58 Art 690.8(A)(1) 1 -way wire length: Manuf TVoc Data Branch Circuit Type A 1 way wire length: 50 1 strings per branch 1strings per branch 2 8 modules per series string 1 11 Imodules per series string Voc= 306.4 V Voc= 421.3 V Vmp= 248 V Vmp= 341 V Isc= 9.26 A Isc= 9.26 A Imp= 8.55 A Imp= 8.55 A Icont= 11.58 A (cont= 11.58 A Art 690.8(A)(1) 130 208.94 345.01 600 13 50 1.a Conductor: 1 AWG #10 PV Vire Icont * 1.25 = (Amps) 14.47 30 deg C ampacity = 40 2.a Conductor 1: 1 AWG #10 Conductor 2: 1 AWG #10 Icont * 1.25 = (Amps) 30 deg C ampacity = conductor 1 Conductor 2 14.47 14.47 40 40 1.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 11.58 40 2.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 11.58 11.58 0.41 40 40 1 0.41 0.41 16.4 0.8 0.8 1.c Icont * 1.25 = (Amps) 14.47 40 13.12 13.12 2.c Term 1 Term 2 Temp table 90 °C:Tab ®ORiC ffip.15(B)(16) lcont*1.25= (Amps) 14.47 14.47 Ampacity 40 40 1.d Icont * 1.25 = (Amps) OCP Size = 14.47 15 Inverter Type A Output ABB PVI -3.6-S AFCI 1 way wire length: 1-01 ft Icont = 16 1 A Art 690.8(A)(1) 2.d OCP Size 1 151 15 Combined Inverter Output Service Voltage= Total Inverter Power- I way wire length= 15 (cont = # of inverters*max inverter current Art 690.8(A)(1) (cont = (Amps) 3.a Icont * 1.25 = (Amps) OCP Size = 20 Art 690.8(B)(1) Art 240.6(A) 20 3.b Conductor: AWG #10 (cont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 20 40 4.a Icont*1.25 = (Amps) OCP size 40 Art 690.8(B)(1) Art 240.6(A) 1 401 4.b Conductor: AWG #8 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 40 55 3.c (cont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity 16 40 0.91 4.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity 32 1 55 36.4 0.91 3.d Icont * 1.25 = (Amps) 20 Ampacity 35 1 50.05 4.d Icont * 1.25 = (Amps) Ampacity 40 50 CONFIDENTIAL -THE INFORMA710N HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR SHTOF ALL ITYONEBE DISCLOSED SOLARCITY N WHOLE ORCIN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY ING JOB NUMBER JB - 9224096 0 0 PREMISE OWNER. FLOREK, NANCY 52224 AVENIDA MADERO LA QUINTA, CA 92253 7607777238 DESCRIPTION: FLOREK RESIDENCE 10.335 KW PV ARRAY PAGE NAME ELECTRICAL CALCULATIONS DESIGN: Eric Smith J i„ OI ' MOUNTING S Til ZEP ZS TilEM.e WTile MODULES: (39) KYOCERA # KU2656ZPA Way 3055 MateCleao, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcityaam SHS: REV: DATE. PV 6 7/29/2015 INVERTER ABB # PVI-3.6-OUTD-S-US-Z-A ' k. - ION. I - POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE -.FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: Address: -52224 Avenida Madero AC DISCONNECT UTILITY, -- -z_` SERVICE .. 1ZIZ - . L INVERTER AND ' DC DISCONNECT ' INVERTER AND DC DISCONNECT r — — — — — — — — — — — — — -- — — — — — — — — --- SOLAR- PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9224096-00 CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT FO USED FOR THE. BENEFIT OF ANYONEEXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARCITY INC. NUMBER I v B— 9 2 2 40 9 6 0 0 PREMISE OWNER: DESCRIPTION: FLOREK, NANCY FLOREK RESIDENCE 52224 AVENIDA MADERO 10.335 KW PV ARRAY LA QUINTA CA 92253 , °+ PAGE NAME 7607777238, SITE PLAN PLACARD DESIGN: Eric Smith 4 tN, =SolarCit /„ MOUNTING SYSTEM: ZEP ZS Tile WTile MODULES. (39) KYOCERA # KU2656ZPA 3055 Clearview way San Mateo, CA 94402 (888)—SOL—CITY (7658-2F.(650) 89) ww638-1029 al Tcltyaam SHEET: REV: DATE PV 7 7/29/2015 '"ABB PVI-3.6—OUTO—S-US-Z-A ©N Vmp =240 VAC Imp=32 AAC - (1) AWG /B, THWN-2. Blade Reef .................................... THWN-2, -(I)AWG A THWN-2, White NEUTRAL -(I)AWG I & THWN-2, Green EGC/GEC - (1) Conduit Kit; 3/4' EMT (1)AWG #10, THWN-2, BladeII (1)ANG p0, THNM-2, Blade Voc* = 388.13 VDC Ise = 9.26 ADC O rF (1) AWG /10, THWN-2, Red O Is?1- (1)AWG #10, THWN-2, Red Vmp = 279 VDC Imp= 8.55 ADC -(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC ..LL. 1 AWG /IP..1H"-:2, PrM.. EGC.. . . . ... . . . . . . . ..... , , (I?1AWG. A THNN-2,.Aem , , EGC/GEC,-(1)CanduH, Kit; x. EMT , , , , , , , , , 1 AWG n0, THWN-2. Blade Vac = 474.38VDC Ise = 9.26 ADC ® (1) AWG 110. THWN-2, Blade © (1) AWG #10, THWN-2. Red Vmp = 341 VDC Imp= 8.55 ADC 1 (1) AWG 010, THWN-2. Red ...... 1 AWG TIO.. THWN-:2, ".. EqC............................ . (1)AWG 010, THWN-2, White NEUTRAL Vmp =240 VAC IMP --16 AAC 1 AWG #10, THWN-2, Blade Vat*=474.38VDC Ise =9.26 ADC . .....-(1)0gA 7HNN72,,Greea.. EGC/GEC.-(1.)Con0u!R,Kit; 3/4 ,ELT........ . O (l)AWG #10, THWN-2, Red Vmp =341 VDC Imp= 8,55 ADC 1)AWG j10,.7HMN-2e Win.. Ems ................ . ®(1)AWG #10, THWN-2, Block Voc* = 345.01 VDC Ise = 9.26 ADC g (1)AWG /10, THWN-2, Red Vmp = 248 VDC Imp= 8.55 ADC (1)ANG. #I9,.ly"—:2, Gre?n.. EGC............................. CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOM01Y INC JOB NUMBER JB -9224096 0 0 PREMISE OWNER: DESCRIPTION: FLOREK, NANCY FLOREK RESIDENCE 52224 AVENIDA MADERO 10.335 KW PV ARRAY LA QUINTAr CA 92253 PAGE NAME 7607777238 SINGLE LINE DESIGN Eric Smith : \` „SolarCity. PV ARRAY #1 MODULES. (39) KYOCERA # KU2656ZPA ELECTRICAL ONE LINE DIAGRAM INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A 11 MODULES KYOCERA EXISTING ELECTRICAL SERVICE ENTRANCE r — — —n1590 56ZPA AND LOAD CENTER 2 i ATT (C 200A 240V 10 l 200A MAIN BREAKER ' PV ARRAY #2 200A 2P ZDC -- — — — — — — — — — — — — — — — — — — — — — —J 9 MODULES r — — — — KYOCERA -------------------------- #KU2656ZPA ° PHOTOVOLTAIC SYSTEM UTILITY AC COMBINER PANEL I 3445 WATT ([ DISCONNECT SWITCH BRYANT # BR8161_125RP ; CUTLER HAMMER # DG222URB LOAD CENTER; 125A i 3600 WATT UTILITY INTERACTIVE INVERTER (E) METER# 16AS-103107 60A, 240VAC 120/24OV, NEMA 3R 120 TO 600 VDC TO 120 240 VAC 10 / i POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z—A PROPOSED BI—DIRECTIONAL 1 I4 METER 40A 2P 20A/2P I —------ -- --- -------- ------------ ------ ---- 20A/2P PV ARRAY #3 I I 8 MODULES I L_______ -, KYOCERA ' I — — — #KU2656ZPA i 2120 WATT (D TO SNGLEOPHASE r AC PV ARRAY #4 UTILITY SERVICE I I — — — — — — — — — — — — — — — — — — — — — — — — 11 MODULES i — — — — — — KYOCERA I DC — — — — — — — — — — — — — — — — — — — — — — — — —— --- #KU2656ZPA 1 2650 WATT (C 3600 WATT UTILITY INTERACTIVE INVERTER 120 TO 600 VDC TO 120 /240 VAC 10 — POWER—ONE # AURORA PV1-3.6—OUTD—S—US—Z—A ©N Vmp =240 VAC Imp=32 AAC - (1) AWG /B, THWN-2. Blade Reef .................................... THWN-2, -(I)AWG A THWN-2, White NEUTRAL -(I)AWG I & THWN-2, Green EGC/GEC - (1) Conduit Kit; 3/4' EMT (1)AWG #10, THWN-2, BladeII (1)ANG p0, THNM-2, Blade Voc* = 388.13 VDC Ise = 9.26 ADC O rF (1) AWG /10, THWN-2, Red O Is?1- (1)AWG #10, THWN-2, Red Vmp = 279 VDC Imp= 8.55 ADC -(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC ..LL. 1 AWG /IP..1H"-:2, PrM.. EGC.. . . . ... . . . . . . . ..... , , (I?1AWG. A THNN-2,.Aem , , EGC/GEC,-(1)CanduH, Kit; x. EMT , , , , , , , , , 1 AWG n0, THWN-2. Blade Vac = 474.38VDC Ise = 9.26 ADC ® (1) AWG 110. THWN-2, Blade © (1) AWG #10, THWN-2. Red Vmp = 341 VDC Imp= 8.55 ADC 1 (1) AWG 010, THWN-2. Red ...... 1 AWG TIO.. THWN-:2, ".. EqC............................ . (1)AWG 010, THWN-2, White NEUTRAL Vmp =240 VAC IMP --16 AAC 1 AWG #10, THWN-2, Blade Vat*=474.38VDC Ise =9.26 ADC . .....-(1)0gA 7HNN72,,Greea.. EGC/GEC.-(1.)Con0u!R,Kit; 3/4 ,ELT........ . O (l)AWG #10, THWN-2, Red Vmp =341 VDC Imp= 8,55 ADC 1)AWG j10,.7HMN-2e Win.. Ems ................ . ®(1)AWG #10, THWN-2, Block Voc* = 345.01 VDC Ise = 9.26 ADC g (1)AWG /10, THWN-2, Red Vmp = 248 VDC Imp= 8.55 ADC (1)ANG. #I9,.ly"—:2, Gre?n.. EGC............................. CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOM01Y INC JOB NUMBER JB -9224096 0 0 PREMISE OWNER: DESCRIPTION: FLOREK, NANCY FLOREK RESIDENCE 52224 AVENIDA MADERO 10.335 KW PV ARRAY LA QUINTAr CA 92253 PAGE NAME 7607777238 SINGLE LINE DESIGN Eric Smith : \` „SolarCity. MOUNTING SYSTEM: ZEP ZS Tile WTile MODULES. (39) KYOCERA # KU2656ZPA 3055 Clearview Way Mateo. CA 94402 T:(650) 638-1028 F:(650) 636-1029 (888)-SOL—OTY (765-2489) www.solarcity.com SHEET: rsEv DATE -son PV 8 7/29/2015 INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A (INV) Per Code: CEC.690.5(C) T• Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. WARNING ELECTRIC SHOCK HAZARD DO (VOT1TOUCHjTEF2MINALTS TERMINA SOIJ BOTH LINE AND LOADZSIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Set Label Location: - (AC) Label Location_: l k 7 ' (DC). - f Per Code: '-- CEC 690.17C+ ' `.. CEC 705.12:D.7 II - r, Label Location: - Label Location. t " (POI) y (C)(IC)(CB) ,f - CEC 690.54; CEC 690.1 4. Per Code: CRC R331.2 Label Location: PHOTOVOLTAIC D(DC) (INV) y.. DISCONNECT Per Code: -- CEC 690.14.C.2 r Label Location: (D) (POI) Per Code: CEC 690.64.B.4 . Label Location y - t I -e (DC) -(INV);, Per Code:• CEC 705.12.D:7 Per Code:'' ' - s • e CEC 690 53, MAXIMUM SYSTEM V - F s'w SHORT-CIRCUIT 12_ Rte-, {` Label Location: " x (DC) (CB) - ,, ELECTRICAL SHOCK HAZ.. Per Code: - - - . • •• CEC 690.17 t }TERMINALS ON BOTH LINE AND LOAD SIDES E ENERGIZED IN THE •-• -POSITION `. DC VOLTAGEALWAYS PRESENT WHEN SOLARe. ` . EXPOSED • SUNLIGHT Label Location: ti (INV) Per Code: CEC.690.5(C) T• Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. WARNING ELECTRIC SHOCK HAZARD DO (VOT1TOUCHjTEF2MINALTS TERMINA SOIJ BOTH LINE AND LOADZSIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Set Label Location: - (AC) Label Location_: l k 7 ' (DC). - f Per Code: '-- CEC 690.17C+ r CEC 705.12:D.7 .41 4r An Label Location: (DC)(INV)(CB),r Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED 3 fel,. V . c! .G - • 1 i • R F . Y f!. R y S ,,.1'.. - C Ty OF,L UILD 4A ` , '• .. ANG SAF P ETY pEPT Y y. - R CQ►S Flo UC ® s r 5. + (AC): AC Disconnects ' (C): Conduit (CB): Combiner Box ' (D): Distribution Panel ;. (DC): DC Disconnect (IC): Interior Run Conduit - (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Ps" 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 our.. (888) -CITY (765-2489) wwwsolardty.corn 0 Label Location: - f (POI) '' - '-- Per Code: CEC 705.12:D.7 II - r, Label Location. t " (POI) y - Per Code: CEC 690.54; CEC 690.1 4. y.. r Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: I (POI) Per Code:• CEC 705.12.D:7 _ •' ,.r .41 4r An Label Location: (DC)(INV)(CB),r Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED 3 fel,. V . c! .G - • 1 i • R F . Y f!. R y S ,,.1'.. - C Ty OF,L UILD 4A ` , '• .. ANG SAF P ETY pEPT Y y. - R CQ►S Flo UC ® s r 5. + (AC): AC Disconnects ' (C): Conduit (CB): Combiner Box ' (D): Distribution Panel ;. (DC): DC Disconnect (IC): Interior Run Conduit - (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Ps" 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 our.. (888) -CITY (765-2489) wwwsolardty.corn 0 "SolarCity I ®pSolar Next -Level PV Mounting Technology I Q SolarCity I ®pSolar Next -Level PV Mounting Technology .Zep System for the roofs using replacement tiles 4Q eMPgT e! ti IvOOMPPrOv @LISTED zepsolar.com ta, .r ,p ropy cCfdintp Top 4maak _i Tap MpatUtb•tp. Mdemati.R w.TL « rtuaty, v p MW kv I aa;o Up A- amiaw.m prc. W .M_Q chil Yp aow .p en. Poof.iwwig ' ;. awniqwft. Rt - ti Description • PV mounting solution for concrete tile roofs • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL -listed hardware creates structual and electrical bond Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Culsheet Rev 02.pdf Page: 1 of 2 Components 1' - Replacement S -Tile Part No. 850-1435 Listed to UL 2703 Tile Roof Attachment Kit Part No. 850-1434 Listed to UL 2582 f) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 zepsolar.com Replacement W -Tile Part No. 850-1437 Listed to UL 2703 Interlock Part No. 850-1388 Listed to UL 2703 Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421,850-1460, 850-1467 Listed to UL 2703 Replacement Flat Tile Part No. 850-1436 Listed to UL 2703 DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.00m. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 2 of 2 s s . , . - •f +✓ - - , ... } .fir . • , i 9., .. , S r- ti~ y -■r. ' •. `4.- .. - . ..., i _ - - ,{- a t r J :' - - ' rk's _ _ t .i. iii • •, - frr _ ,F t'T . - - 3 • I% .. »r. :i r - , J" ,rF 4a t•s ,•off t ti 10,- V iS j • - ,• , _ .. _ - _ c, j t• - f L 7'x`54 _ _ • - _. ' e x: of , Additional highlights: + r A.' Solar 4 { , RS-485 communication interface r ,.•t r r' string _>., r 3. (for connection to laptop or data , ,,; + ` a,; : 4"'• \. ` - - . ' ` 04, 'r T' Jogger). , y * { -3.0/3.6/3.8/4.2 R y' f - — Integrated Arc Fault Detection and ', s , },,'i ¢ , ' „ • F" I "(. i ' 1 ` Interruption (-A Version) a . i • `,a' 4 t4 y: , p 3.OkW to 4 -.#+'` y" -•;; sf , rt , i Y- ,, It ,„ " ;: ,z: 3r +• . i' L* c .. t -;4 * c f 'x'+_ ' '-c ,*. -^► -v. f ♦n'•• ' , wtt; r:1 - - .- -' •_ , - .. f !. "? '. r' ••',- -^. " ' ' .. ta'' al, r+ ..,•ta { TFy ... ` - - tv .,' P . _ 1 _• . f jy+ - ... .. t C • " ., -' , rT.- _ L. • .u., v - _ '!-.s F - , ♦ ''4 +r.r '.Y c',• ' - ---„.---'•+,,,, .V . • t ,y' ..' •:F-. } ' 'Y ;y• '.fit: 4` ;"1, ' f t. ` " - i•'. "V '}'.z •Y f,-. z;.`..i- r r L . 'N - .- _. - V.'l.. •. , .<..."F f i -rte •. 3. # w •' '1 h. j. y, `• t a Technical data and types 4 -4• ` raw - .. g ti - - ., .j ., .•. . ' , ,':. - ti . s ' , _ . , , - 4 ' r r '„ ' v ♦ Type code t PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US - PVI-4.2-OUTD-US r - •. . 6 Mechanicalspecifications. _ ' c - ti _ - I ,- 0 1 ' 3 +--•-- , ,,,. Norninaloutput power y •"-• .3000w+ .3600W.330- 3800W .4200W _ _ _ , a • < .........................:.:..:.................................................:..c.............. i.....:.................:..........:... ...:............:..:....:....s. , • • -- _ [ 3000 3300' ; 3300' i' 3600 € '4000 4000' :3300:4200' 1 4200 4200 i 4600' 4600' w p Maximum output power wattage , r ...t - • , "„i i W ,W.^ W W W W W W W- W W W +. ,,f, } .,, ,. .. ° . ,. i ...d... - .,:................g,ri..,.,....................,........................................................;..................,.... ..........i..:........ _ .. ......... - r - i + + `• . r _r : Rated rid AC voila a <208V i 240V 277V 208V ( 240V 277V 208V 240V 277V ( 208V ` 240V ` 277V l l Input s de (DC) - — r` Number of Inde endent MPPT channels 2 2 : 2 2 ” • n : .. ...... ' , n ... • - • 5:' = Maximum usable ower for each channel 2000W 3000W 3000W 3000W ' s s P i - ' ..... . •: •,., ,fir` ..... ............................... ... - Absolute maximum voila a max) . 600V + L Start-u voila a (Vstart) ..• 200V (adi. 120-350V) r.e Full dwer MPPT voila a ran e' 160-530V 120-530V 140 530V 140-530V - ; P........................................9............ 9.........-....-.......................;.:................................................. ....:.............................,,......... s . - y' :.h . : ` f6ii '• ■ PT volta a ran a 0.7 x Vstart:':.i580V...>=90Vj........................................ h-:f Operating_ 1P..........)........ .......... _9................, ..'..:.:......i.................................. .... (................... '..........._'.....- . • r - - t Maximum current Idcmax for both MPf57ln .......... .. ............ ....................................... b l / fL i A A a 20 32 32A 32A . arallel _ s r. 7 ' . ' r :x` x *: y$. .r a Maximum usable current er channel...... 10A... 16A..... 16A... 16A... } P......................... .......... .......19......................... ....... ...................... ........................................... ,..y,,, •` . Maximum short -circuitcurrentlimit per , - {. r Al P +..channel p 12sA. ;' • 20.OA 20.OA 20.OA . .. ...................................................................................................................... Number of wire landin terrn bats er channel i .. 2 (airs, 9........................p.........................................:......................... P.............................. _ _• .• - ; oc"erM",b ,., _ ^- , „ `f t ' - , Array wrong termination - _ _ * Terminal block pressure clamp, AWG 10 AWG4 ;• r =' >r • , 'F ` .. + 5.' - ".- .. :,,• '. fOutputside (AC),.-. Grid connection type ; ` ,. - 10/ Split ; - 10 i' 10 - i Split- i 10/ i 10 € Split- i 10 i 10/i Split- .10/, 2W 0/3W i 2W 2W 0/3W i 2W . ' 2W i 0/3W 2W 2W i 0/3W i 2W y. ......... . _Ad'ustablevolta`eran a min-Vmax :i 183 i 21..1 - 244- 183- 271- €•••244- 183- 211- 244- € 183- i 211-' € 244-, _ I 9 9 (V ) M 228V i 264V i 304V 228V 264V i 304V i-228V 264V 304V i 228V i 264V € 304V ` / • , -r r ..grid frequency OHz .. , r- 6 r • Adjustable rid fre uency ran a 57-60.5Hz ...................g.............9.......................4....................................................................:..'...:.........:........: r i' Maximum current (la.:,,",) e .....14.5 14.5 12.0 17.2 1fi:8.....•.•16:0 •'. •••"1•fi:OT'.•• 16.0€:..:.fs:o_...:.....2 . .... ....20:0:.........2i):o.._ tY • .k • ,., - . _j '+ - T''. ,.,, ............ .......... ............. .................... Aarns....:.....! a.,s. Aams....!...... °`afn's p`a ns...f....Awns. Aarns ......A. A ...E.....Aans ..i. A..u.....': Power factor > 0.995 ~ . •........................................... ....... .......... ...... ........................................................................................................................................................ i•' , • '` Total harmonic distortion at rated power r „ <2%. This family of single-phase stung The high-speed MPPT offers real- . Highlights: .✓ Grid wiring termination type Terminal block Pressure clamp, AWG10 AWG4 } ' inverters complements the typical- time power tracking and-improved ` ,— Single phase and split phase output , a )input protection devices x I },i r Reverse olarity protection Yes _ P.........................,........................................................?.........................................................................:............................... number of rooftop solar panels , energy harvesting• grid connection. 1 x.......c:..................................................... , y . Over-voltage..P..rotectlon.?Y..P..e........................................... Varistor,._2 for each channel.............................................................................'.......... . . T . enabling home-owners to get the most The flat efficiency curve ensures high . Wide input range for increased F f.PV array ground fault detection Pre start-up Riso and Dynamic GFDI (requires floating arrays) ' efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. (Output protection devices t ' !,.r AnTt tslandin rotection - Meets UL 1741/IEEE1547 requirements . : 9.P...........................................................................................................'` of the property. 4 a consistentandstable performance The high speed and precise MPPT •'. - >' .. Over-voltage rotection t e ` Varistor, 2 - Lx i G..... P......................_,Y..P...................................................................................................:..,......................................,.....)............,........:..........:...................:...................:.................._ across the entRe input voltage and algorithm offers real time power " : Maximum AC OCPD Rating 20A, ° ° 20/ , °' 15Ao • : 26A°,° 20A ,, 20Ap„ 20A,• : 20Pb„• : 20Fap„• _ This inverter offers a dual input output power range. tracking and improved energy Efficiency r. jE ' Maximum effciency 96,9% 97% 97% 97% section that processes two strings The transformerless operation gives the harvesting. ' ....... rc - CEC efficiency ...... .... ........................................... .......................'..96%• • ' • with independent Multiple Power Point highest efficiency of up to 97.0%. Outdoor NEMA 4X rated enclosure [Operating performance ' Tracking (MPPT). The wide input voltage range makes for unrestricted use under any 1• , Night time consumption <.0.6W_,, ' Stand-by consumption < 8W°„1 ' This is especially useful for rooftop the inverter suitable to low power environmental conditions. + [ - — • ;..r (Communication _ installations with two different installations with reduced string size. Integrated DC disconnect switch •, .r User-interface 16 characters x 2llnes LCD dls la _ t......................... ....... .............................. .............. t. orientations from two sub-arrays This rugged outdoor Inverter has been In compliance with international Remote monitoring (1xRs4a5 incl) VSN700 Data Logger (opil'i y - w oriented in different directions. (For designed to be a completely sealed Standards (-S Version).. IEnvironmental •j Ambient atr operating temperature range 13 F to,+140°F with derating above 122 F (50 CI•••.....-•••••••..••.... = example: East and West) unit able to withstand the harshest ;f;_ - Ambient air storage temperature ran a 40 F to +176 F =4o°C To +ao C ' 9.......................................................................:.....................................................................(....................................).............................................................. The dual input sections with environmental conditions. - Relative humidity o-100% RIS condensin p , g.................................................................................... . Acoustic noise emission level <50 db A.RI.T independent MPPT enable a more .............................................................................,........:...................................:.................................................................................1..)................................................................................................................_ p ?,. Maximum o erahn alt tutde without de at' 6560 ft 2000 m P...............g......,................................................_9........................................................................................................(.................)...............................................................................................'.... _ optimal energy harvesting condition. „ 11 1! a 1, Capability enabled at nominal AC voltage and with sufficient OC power available + Power and productivity _ - for a better world'”" ',F%191 - 1T..,:.y 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD ! - _ KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS Ig K90CERa KU -60 10 0 0 V Z SeriesStandardConditions Cells per module: 60 4 i 10) 1000 Dimensions. 65.43ini38.98ini 1.57in KU265-6ZPA length/wid"eight (1662mmi990mmi40mm) Weight 45.21bs (20.5kg) CUTTING EDGE TECHNOLOGY P„" 265 w As a pioneer with four decades of experience in the V-11 31.0 v PACKAGING SPECIFICATIONS development of photovoltaic systems, Kyocera drives the lmP 8.55 A Modules per pallet 20 market as a leading provider of PV products. We------ ----- — ------- demonstrate our Kaizen philosophy, or commitment toMEN V_ 38.3 -- — J V Pallets per53'container 36 continuous improvement, by setting the industry standard — - -- — - Pallet box dimensions: 66ini40ini43in in the innovation of best -in -class solar energy equipment. l 9.26 A length/width/height (1675mmi1005mmitO55mm) P +51-0 % Pallet box weight 1015Ibs(460kg) taernse QUALITY BUILT IN Nominal Operating Cell TemperatUre Conditions (NOCT) • UV -stabilized, anodized aluminum frame in black ' t•• • Supported by major mounting structure manufacturers TN«T 45 .. °C • Easily accessible grounding points on all four corners P ,, 191 wNCTION K; POITED for fast installation fv 27.9 V CABLE W/ ❑ • Proven junction box technology with 12 AWG PV wire Ll " 6.85 — A C018,EC,°R LABEL works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors - v provide safe, quick connections l 7.49 A PROVEN RELIABILITY Fcrn 238.1 w , • Kyocera modules confirmed by the Desert Knowledge. - Coefficients Australia Solar Centre to have the highest average output of any crystalline module P,,,,, -0.45 • First module manufacturer in the world to pass long- Veep -0.48 %/°C term sequential testing performed by TUV Rheinland0.02 - --- - - -------T T - • Only module manufacturer to achieve the rank of ' lm° 38.98-(990.W "Performance Leader" in all six categories of GTM Voc -0.36 %/°C Research's 2014 PV Module Reliability Scorecard l T 0.06 CERTIFICATIONS Operating Temp -40 to +90 °c Grounding Hole Slotted 8ountint Hole 0.16' t4e0 0.36-.o.47- ( lW • UL1703 Certified and Registered, UL Module Fire Systern Design Performance: Type 2, CEC FRAME CROSS SECTION DIAGRAM • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 series Fuse Rating 15A `oMPAT/A Maximum DC System Voltage (UL) T -T'— 1 o00 v Hailstone Impact in (25mm) @ 51 mp C m(23m s) c V L US O JBL u 0 'Subject to simulator measurement uncertainty of +l- 3%. DMPP KYOCERA reserves the right to modify these specifications without notice. LONG/SHORT 610E WARNING: Read the insuuction manual initsmtiretypriorto handling, installing & operat- my Kyomra Solar modules. 040215 OUR VALUED PARTNER 6 7 6 5 4 S 2- 101 _O ' 9.11 [2311 7.36 [1871 •- 8.66 [220] 1 .33 (8] 06.41 (m3] R e TV OFF y J CONCENIi6C KNOC1t0U14 FOR TANGFN1w1 KNOCKOUTS FOR • A ® ® ® 1/2.3 1. 1. 1-V6. CONd1R J/wry i1/4 CONDUrt O 1 .— .0 (11] nwEfaUNeRl NDGlw Naos T;! [22] B - B J.. r 04.28 hzq. TANGENTNL KNOCKWiS FOO CONaUrt NOTE: I. YEINC N.Im N5 (W 16WwflERS) ARE RANWII W KESS. Z Waif RANGE OF ClpS 6 1/0-I14 COPPER OP ALWWUw. r r 1.36 rr (35] r J KNOCK 6.K ' OIlANi1fY 1 A .. 8.10 [213] A C• y K.umIN m CUTLER - HAMMER W.T'N GM a.EN51OH SH W MIP EET TYPE 3R GENERAL OUTY ITI "95-1451 Mr, 1 .7 6 5 4 3 2 1 0. ®. ZS COMP I GROUNDING AND BONDING ZepSolar ZepSolar ZS CompTM I Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the LIL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Zep Compatible' systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Document 800-1478-001 Rev A www.zepsotar.com PAGE: 1 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 2013 4:45 PM Interlock Interlock Zep UL Listed to UL27 Tongue side Key Side Bonding Cutting 'tooth' Key side in Q closed position Cutting 'tooth* Tongue Side Bonding Tongue side in closed position Cutting 'teeth* Side view Interlock Module i Bonding locations on Key side Forced interference during rotation of Interlock Zep causes teeth to cut through anodization on module frame, resulting in robust and UL certified bonding path OModule r_ Bonding location on Tongue side O Forced interference between mating parts from module rock -in motion cuts into module frame, removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsotar.com PAGE: 2 of 5 ® 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 20134:45 PM 77 T. ,ry VIS i a'.rw t •.: • ,. M• ,`y r 7,.` y. a. •`tr 7 rt`: yj ; ., - - V: ;. , C , +, . -.,al` . ,• -- i ,+.,'. 'f 5 _ _ - • _ _ - c -• -, ,. - - _ , r ,. ♦ . .'. . '. A3 _ : '1. - _ , µ _ - ' - - } - - ., k "' Lin ZepSolar ZS COMP I GROUNDING AND BONDING ZepSOlar ZS COMP I GROUNDING AND BONDING i' >. t wLeveling FofInterlock, continued. o .; +. f --. y _ - tS- 4 Tongue side• ,- — Key side • c ?( a w 1 x ,F i y } l _.'ft ni 4.0 ,'^ a<.. ,a•• -o - f' - --•, - r - - , . t - . :i • %?' 1 «Ax _t7, ., . - - 41 Spring clip { • =.r . `. - r _` * . -rt- - r •,^<.. ryw _ ^- . 71 PartNo.850-1388. }y' • - ,... - - - UL Listed toUL2703 ,+r. .. r , ,y'. - - • ri . Tl r r - , xv, - -fir , • 7 ,y - - r?! .. - - .. - ,' n , 850-1397 Part No . . , " " The Leveling Foot to • , - - ry -BondingPath - Ke and Tongue top (the Rockit) hasas[ainless steel _ __Y .. tip , ?•- a 7 ' t, UL Listed to UL 2703. spring clip that bonds to the adjacent module frame on both F i• y e : , 4 The Interlock bonds modules on all 4 sides to create a hyper_ _ n - " Key and Tongue sides.- - T , '{ ' •' ',, - .• "" y - -y _ -. - bonded array where every module is structurally and -_ - - i , ' - • - r } F • ` r + Y a,,^ electrically bonded to the surrounding modules.. - . ,r •••'Fa .may ry < y,,,; _ - - nr {f Leveling Foot`- " Bonding With Module Frame' • . r` - '- - u r t Ir .. .7 i. (Module Down -roof _ - - 1 ` Tongue side t Interlock Key side Key side inserts Into Zep Groove (rock -in) - Module in next row drops in on the Tongue side a Bonding Path - Array < _, ; Sy .Bonding Path -North and South Modules o Interlock - • - Bonding location on Key side Bonding path r #.; _® _ , - • O ` + ± _ ® ® Leveling Foot - `} _ - • d. ® Bonding path , - pr. • }' - y 7. A WN UK a . "► ' Bonding location on Module rotation during drop-in creates forced _ ' Down -roof Tongue side interference between Zep Groove and spring clip, - Down -roof cutting into module frame, removing anodization and - resulting in robust and UL certified bonding path . - Document 800-1478-001 Rev wwxr.zepsolaceom - . Document 800-1478-001 Rev A - www.zepsolareom PAGE: 40f5 - •' - PAGE: 3 of 5 - . - 02013/EN Zep Solar, Inc, Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved.- .`', .'r 0 20131E Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior not All rights reserved. _ Date Last Exported: June 25,20134:45 PM - •-:r -ice. Date Last Exported: June 25,20134:45 PM - ♦ ' .t. .. 10. ZepSolar ZS COMP I GROUNDING AND BONDING Ground Zep Set screw Part No. 850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation Key side Ground wire channel The Ground Zep provides a single point of connection for theEquipment Grounding Conductor (EGC) from the array to a building ground. 2 O 4 F_V_T i C J Insert Ground Zep into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees, so that set screw Insert copper EGC Into ground wire on array perimeter is pointing straight up. channel. Tighten set screw using torque values shown In the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground (» Ground Zep Equipment Ground Conductor Bonding path I Down -roof Document 800-1478-001 Rev A www.zepsatar.com PAGE: 5 of 5 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25.20134:45 PM c a•..}' ` .:y . M1 :a~ 'f - 1 ' • * . '.f ,•ti "9- t _ 4... a' j'1 - i a • -y - , - - _ _ o !, _ v.+" _ •A. _ a . •, 1. 'f • 1":, i 'TK t• Gr+,I r -r' \ .. . •. e SolarCity Standard Box 4J 'w = ".w NOTICE OF. COMPLETION ,. t `AND ' '} • AUTHORIZATION TO APPLY THE UL MARK/ a ' The SolarCit Standard Box 4J is a Manufactured to meet UL 1741 Standards. , y i - - ». ±' c' ` , r 12/21/2013 " ' c r r 4'String unfused Junction Box. The box _ solarcity corp a Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. ; • a Alex Yang "',; r • ` f r k' is highly configurable and adaptable ,° }si' 3055 Clearview Way 1 Y - ~ r • Factory -Installed Cordgrip Enhances Installation Speed . ' San Mateo Ca 94402-3709, Us- ' 4- using,the (4) jumper blocks included in , - t ,a",, s _ • each box. A factory installed cordgrip •Break-Thru Skinned -Over Glands on Cordgrip Provide' enhances installer. productivity. Weathertight Seal for AlI Configurations. Our Reference: E318537,.•Volume;l . Project Number ``. 4786083586 - • E. .! a _ - 4 . 1. Your Reference:. A.. n 10/7. + }' kA • .z s , " • Easily Configurable Terminal Blocks Permit Adaptation • - is of -r : • a .7' Project Scope: ' Invesbgatiori of Photovoltaic (PV) System Combiner Box, modetlSolarCity Standard Box 4C" h, " {. y `. r to Site Stringing Needs. - ,and"Photovoltaid(PV) System Transition Box, model"SolarCity,Stan4ddird Box 4J" to UL 1741 ^, ,. ri Standard;;., - _ _ +• - ,. _ ;i•.e n 11r ' » tiy` iy• apq• Dear Alex Yang:l ,. _ a .. 'Y r f "n: r"^t1 _• a , Si • s .t • F ' * Congratulatlons!rUL's investigation of your prodctO has been completed under the above Reference NumBler and +t Technical Data /Specifications r. , :' > w y the product was;determined tocomply,with the applicable iequirements." This letter temporarily supYplements the.,UL . _ :^_ •Y ,I Follow -Up Services Procedure and sanies as authorisation to apply the UL Mark at authorized factories under UL' ,• _ ©A Voltage Rating [VDC] : 600V ' r. Follow -LID Seivice Program. To provide your manufacturer(s) with the intended authorization to use the UL/Mark, ( , ' you must send a copy of this nohce t& each manufacturing location currently authorized under E318537;>,Volume ts. OB Maximum DC Current [A]: 57A i r and rncfudrng any special instruchons'as indicated rn the,addendum?o this letter. - -• .. ,, 4Tf.. - -'.'f- . ,f{r' f fR •.' 4" = ,{1J {x•'1 .- 4a.. - •• s _ 3 .. .... • _, ® _ ©Maximum Continuous Current [A]: 42A v Records'in he Follow -Up Se res Procedure covering the product lire now being prepared and will be sent Irithe St , >, t c nearfuture-. Until then, this letter'authoriies apphcation.ofthe UL`Mark for 90 days from the date indicated above: t. O Maximum Voltage [VDC]: 600V p t , r ibilities related to Earl Authorizations" that can.be found at the followingweb-site: R E Wire Size Range [AWGI: #6 to #14 y ` . ► v 'S ' - resplolnsal requirements related to our responsibilities as- he Applicant can be found in the document "Applicant _ C) g [ ] Enclosure Rating: NEMA 4X s '` httoaAniww.ul:comlEAResoonsiblldies t , P 9 [° ] - n information and documentatlon.pro ' f dprovidedt `t any authorized licensee of 17L,tl r + r g G Operating Tem Temperature Range C 40 to 50 Ir ' . Y Y A )' y d,to ou.mvolvin UL"Mark services are on behalf of UL LLC UL or !.w p tai► . _ Typical Overall Dimensions [in]: 8 x6' x4" - ~ We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free -to " ' contact me or,any of our Customer Service representatives if you have>any questions. { C> Jif ' r _ •,.a , . ' Y _ .,. .t y _ Very truly yours!, Reviewed by: Jon Adonay .1 `' William R. Carney 408-754-6630 a . , 847/664-1088 %-'_ ,• Engineering Associate Lead Chief Engineer Director l < a r s _ Ejll • ` , Jon;Adonay@ul.com.' William.R.Camey@ul com" _ NBKD9C5-90BA67 • _ V, October ® m October 2013 This is an electronically generated letter,. Signatures are not required for this document to be valid. Page 1 of 1 » -