Loading...
SFD (12984)53180 Avenida Madero 12984 TWT a" A' 44 P.O. BOX 1504 _ N o Building 78-105 CALLE ESTADO Address 53-1$O Madero LA QUINTA, CALIFORNIA 92253 Owner' Synercon Development Corp. Mailing Address 74-940 HWY Ill CityZip Tel. Xadian Tells, CA 92213 564-6929 Contractor Sam Address ty lZip I Tel. State, Lic. 655280 (City 24,19 & Classif. Lic. # Arch., Engr., Designer Address Tel. CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Bu ;ness andj,Professiont-Code, and my license is;in full force and effect. 1A+s. - ..E I,! ,4 ,..3 S h- . SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the bast for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (8500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) O I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's 6mpensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject,to7the Workers' Compensation Laws of California. Date Owner *r C,a 4. iJ +moi i x✓+h J NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST. OCC. GRP. A.P. Number 774-032-007 12984 Legal Description ' Lot 16 Blo--k Project Description's REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line -Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: r Sq. Ft. 1 1 Size No. ,.No. Dw. Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit does not include block wall or pool. Estimated Valuation $107,147.00 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 559.53 Const. 667.50 Mech. _ 49.50 Electrical 135.53 Plumbing 244.00 S.M.I. 19.80 . Grading 20.00 Driveway Enc. ...0,,. Infrastructure 2,315.40 Arts in Publi-_ Places 25.00 •✓ 7 t. s i` 3y, J.4P••i7, il ,"7iMTI 3. 1 )t Yii J. TOTAL 3.926.96 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line -Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS COLL. AREA . r 2ND FL. SO. FT. ROUGH PLUMB. YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. DUCT WORK DRAINAGE PIPING WALL SO. FT. GAS (ROUGH) ,,?Cas [l 77 DRINKING FOUNTAIN SO FT ® HEATING (FINAL) URINAL ESTIMATED CONSTRUCTION VALUATION $ GAS (FINAL) WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER HEATER WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER WATER SYSTEM GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GRADING cu. yd. $ plus x$ LAUNDRYTRAY AIR HANDLING UNIT CFM FINAL INSP. KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ®c BATH TUB FIRE ZONE ROOFING SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® 3/ac HOUSE SEWER GAR. FIREWALLO -30 -4 3 Gp GAS PIPING PERMIT FEE LATHING R-3,0 _ 7 PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBINGS ( / ' UNDERGROUND A.C. UNIT COLL. AREA // SLAB GRADE I% ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS[,%SEWER 1A e7 Of1S2P1'l9iAiM( % C OUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) ,,?Cas [l 77 METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE 11/CCC ! ✓ J GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING tg— (g 'erFINAL INSP. ROOFING o)I —f 3 L/9pl ewi REMARKS: t m ' ' VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALLO -30 -4 3 Gp LATHING R-3,0 _ 7 MESH INSULATIONISOUND,V ? 3,/3 FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL d 6TA 78-105 CALLE ESTADO — LA 00UINTA, CALIFORNIA 92253 - (6191 564-2246 FAX (619) 564-5617 June 3, 1993 Dave Dietrick SYNERCON•DEVELOPMENT 74-940 Hwy 111 Indian Wells, CA 92210 Dear Mr. Dietrick: This letter serves as notification that the address of your home under construction' at 53-120 Avenida Madero, APN# 774-032-007, Lot .7, Block 16,,has been changed to 53-180 Avenida Madero. I am sorry for any inconvenience this may cause you. if you have any further questions, please feel free to contact me.' Sincerely, BUIL ING AND SAFETY DEPARTMENT ,Kelly T pple Counter Technician MAILING ADDRESS P.O. BOX 1504'- LA QUINTA, CALIFORNIA 92253 DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 r. NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 5/13/93 Type of Permit La Quinta. No. 12208 Permit # 63 " 1�0 Log Owner Name Synercon Development Corporation No. 53-M Street Avenida Madero City La Quinta Zip 92253 Study Area 113 APN #1774-032-007 Tract # Lot # 0 Square Footage 11818 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 x 1818 or $ 2,999.70 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By La Quinta Mortgage/David Dietrickl Telephone 564-6929 Name on the check By Assistant Superintendent, Business Services' Fee collected /exempted by Vickie J. Durrett Payment Received r 1 Signature 3406 Check No. 618/3406 Collector: Attach a copy of county or city plan check application form to district copy for'all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/ Receipt Copy - Accounting - DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE0 Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 5/13/93 Type of Permit to No. 112208. P t # L Owner Name Synercon Development Corporation No. 53-120 Street Avenida Madero City La Quinta Zip 92253 Study Area 113 APN # 774-032-007 Tract # I Lot # 0 Square Footage 11818 Type of Development I Single Family Residence, No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages [carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined - the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 x 1 818 or $2,999.70 have been paid to D.S.U.S.D. for the property listed.above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. - Fees Paid By La Quinta Mortgage/David Dietrickl Telephone 564-6929 Name on the check By James E. Lively Assistant Superintendent, Business Services Fee collected /exempted by Vickie J. Durrett Payment Received Signature Check No.618/3406 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/ Receipt Copy - Accounting III it Fri Z h I ­4rm= - , ==-�- � ' ���4'�c-.'All t10' anb �s let� 43 t M atkst tun - This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at thetime,of issuance this, structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 53-180 Avenida Madero Use Classification Single Family bwelling- Bldg. Permit No. 12984 R3' VN SR, Group Type Construction -.Fire Zone- Use Zone Owner of Building Synercon Development _.Address 74-940 Hwy 111, City Indian Wells, CA 92210 BY: Lonnie Day' Date; -December 8,-,1993 Building Official POST IN A CONSPICUOUS PLACE Table Of Contents for Title 24 Report ------------------------------------- CoverPage ......... ...... .......... 1 Table'of Contents ....................... . ........................ 2 Form CF -1R Certificate of Compliance: Residential 3 Form MF -1R Mandatory Measures.Checklist: Residential'.... ............ 5 Form P -2R -Point System Summary. ..... ............................... 7 Form ENV -3 Construction Assemblies ... ... ,,,,,,,,,, g HVAC Zone &Space Loads Summary 12 CERTIFICATE OF COMPLIANCE: Residential (part 'l of 2) CF -1R page 3 of"14 ----------------------------------------- Project.Namec'SINGLE FAMILY DWELLING Date:'4/21 1993 Address: 53-640 NAVARRO' LA QUINTA, CA. Building Permit No Designer: SYNERCON DEVELOPEMENT CORP. Checked by Date. Documentation:,.THOMPSON SERVICES COMPLY 24 'User 1615 GENERAL INFORMATION Compliance Method: COMPLY 24 version 4.10 Climate Zone: 15 Conditioned Floor Area: 1818 sqft Building.Type: Single Fam Det Building Front Orientation: 0 deg (N) Number of Dwelling Units: 1 Floor Construction Type: Slab on Grade BUILDING SHELL INSULATION Component R-13 Wall w/1" EPS Solid Wood Door R-13 Wall (W.13.2x4.16 R-38 Roof(R.3.8.2xl4.16; Slab Perimeter w/R-0.0 Slab Perimeter w/R-0.0 FENESTRATION Orient. Area U -Val Type •U -Value Location/Comments -------- 0.059 SINGLE FAMILY DWELLING 0.387. SINGLE FAMILY DWELLING 0.085 SINGLE FAMILY DWELLING 0.028 SINGLE FAMILY DWELLING 0.900 SINGLE FAMILY DWELLING 0.720 SINGLE FAMILY DWELLING Front N 20.0 0.75 Double Front N 92.0 0.75 Double Left E 36.0 0.75 Double. Back S 52.0 0.75 Double Right W 20.0 0.75 Double Right W 24.0 0.75 Double Right W 4,0 0.75 Double THERMAL MASS Type --------------------- Concrete, Heavyweight Concrete, Heavyweight Concrete, Heavyweight Concrete, Heavyweight Shading Devices Frame Interior. --------------- Exterior ----------------- OH SF -- Type ----- none none N N Wood none Standard Bug Scr N N Metal none Standard, Bug Scr N N Metal none Standard -Bug Scr N N Metal none none Y N Wood none Standard Bug Scr Y N Metal Undefined. none N N Metal Area Thick Covering (sf) (in) Exposed 180 3.50 Covered 1638 3.50 Covered 1638 3.50 Exposed 180 .3.50 r Location/Description Slab on Grade Slab on Grade SINGLE FAMILY DWELLING/Int Mass SINGLE FAMILY DWELLING/Int Mass CERTIFICATE OF COMPLIANCE: Residential (part 2,6f'2) CF -1R. page 4 of 14 ------------------------------------ ------------------- Project Name: SINGLE FAMILY,DWELLINGDate: 4/21/1993 Documentation:: THOMPSON SERVICES COMPLY•24 User 1615 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type_ Efficiency and Location -RVal Type Location/Comments ----------------- ---- ------ ----------------------- PackHtPump 7.100 HSPF Ducts in Attic 4.2 SetBck ENTIRE HOUSE PackHtPump 9.500 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING•SYSTEMS• Heater in Energy Size Insul System Name Distribution Type Type Sys' Factor (gal) R -Val ------------------------------------- --- ------ -- Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0. 12 0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated •Stdby. Tank Pilot System Name System Type Eff Input Loss R=Val Light. Std Gas 50 gal or Less DomesticHW 0.780 40000 4.040 0.0 0 SPECIAL FEATURES/REMARKS COMPLIANCE STATEMENT This Certificate:of•Compliance lists the building features and performance specifications needed to comply with Title 24, Parts -1 & 6 of the Califor- nia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate -of compliance is submitted for a single building plan to•be built in multiple orientations, any shading s feature that is varied is indicated in the.Special Features/Remarksection DESIGNER or OWNER (Per Business & Professions Code) SYNERCON DEVELOPEMENT CORP. 94-940 HWY 111 SUITE 429 INDIAN WELLS, CA. 92210 (619) 564-6929 Lic #: signs ure a e ENFORCEMENT AGENCY Name: Title;: Agency: Telephone: DOCUMENTATION AUTHOR R.E. THOMPSON 365-2140 THOMPSON SERVICES 56020 SANTA FE TRAIL, UNIT A YUCCA VALLEY, CA 92284 (619) 365-2140 -(signature) aej } (signature/stamp) (a e MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page5 of 14 -------------------------------------------------- Project Name: SINGLE FAMILY DWELLING Date: 4/21/1993 Documentation: THOMPSON SERVICES COMPLY 24 User 1615 ---------------------------------------------- NOTE: Lowrise residential.buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with: an asterisk (*) may be.superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications.for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Enforcement o Sec. 150(a)-: Minimum R-19 ceiling insulation. o Sec. 150(b): Loose fill` insulation manufacturers labeled R -Value . o Sec. 150(c): Minimum R-13 wall insulation in framed walls (does not•apply to exterior mass walls). o Sec. 150(1) Minimum R-13 raised floor insulation in framed floors; Minimum R-8 in concrete raised floors. o Sec. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118:. Insulation specified or installed meets California Energy Commission quality.standards Indicate Type & 'form. o Sec. 116-11.7: Fenestration Products, Ext Doors & Infil/Exfil Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 6 of 14 ------------------------------- Project Name: SINGLE FAMILY DWELLING Date: 4/21/1993' Documentation: THOMPSON-SERVICES COMPLY 24 User 1615 SPACE CONDITION:ING,, WATER HEATING AND. PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13 HVAC equipment, water heaters, showerheads .arid faucets certified by the Commission. o Sec. 150_(i): Setback thermostat on all applicable heating systems.• o Sec. 150(j); Pipe and Tank Insulation 1. Indirect hot water tanks (eg unfired storage tanks or backup solar hot water tanks) have insulation blanket �R-12 or greater) or combined interior/exterior insulation R-16 or greater): 2. First 5 feet of pipes closest to water heater tank,. non -recirculation systems( insulated ((R-4 or greater. 3. All buried or exposed piping in in recirculation sections of hot water system. 4. Cooling system piping below 55-F insulated. 5. Piping insulated between heating source and indirect hot water tank. o Sec. 150(m) Ducts and Fans * 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. o Sec. 114:Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot.light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light. (Exception: Non -electrical cooking appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec. 150(k): Lighting- 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. POINT SYSTEM SUMMARY P -2R page 7 of 14- ----------------------------------------- •. Project Name:, SINGLE FAMILY DWELLING ---- Date: 4/21/1993 Documentation: THOMPSON SERVICES COMPLY24 User 1615 - ---------------- BUILDING DATA. ' Conditioned Floor Area 1818 sqft Number of Stories 1 Occupancy Type. Single'Fam Det, SGORE CARD Measure Points 1. Roof Insulation . 0.0283 (U -Value) 0 21. Wall.:Insulation- 0.0626 (U -Value) -2 3. Raised Floor Insulation 0.0000 (U -Value) 3a. Controlled Vent Crawlspace 0.0 .(R -Value) -> 0 4. Slab Edge. Insulation 0.7539 (f2,factor)_ 5. Infiltration Standard 0 6. Glass Heat Loss 0.75 13.6% 0 Sum 1-6 -2' 7. Fenestration Heat Gain SC Orientation Area $ Glass Open Eff % SER North 112.0 6.2 x 0.65 4.0 . East 36.0 2.0 x 0.71 = 1.4 1:00 1 South 52.0 2.9 x 0.71 '2.0 1:00 0 ` West 48.0 2.6 x 0.45 = 1.2 0.89 1 Skylight 0.0 0.0 x. 0.00 = 0.0 0.00 0 8. 'Interior Thermal.Mass 4.15 3- 9. Exterior Wall Mass 0.00,- 0 10. Heating System Sum.7-9 4 1 Zonal Control: No. 11. Cooling System -3 12. Water Heating = 0 ADJUSTMENT FOR FRAMING (1 /14.86) x (0.85) + (1 /'5.3.3) x (0.15) Weight: 6.4 lb/sqft Heat Capacity 1.84 = 0.085 TOTAL U -VALUE _ TOTAL.R-VALUE _ 0.085 11.72 PROPOSED:•CONSTRUCTION ASSEMBLY --------------------------------------------- .,ENV 1 .-3 page 8 o 14., ProJect Name:. SINGLE FAMILY DWELLING Date: 4/21/1993., /21/1993•, Documentation: THOMPSON SERVICES. --------------------------------- COMPLY 24 User 1615 COMPONENT,DESCRIPTION-' Assembly Name: R-13, Wall, (W. 13.2x4.16). Assembly Type: Wall, Assembly Tilt: 90 deg (Vertical,) Framing Material: Wood f Framing Spacing: " O.C. . Framing Percent: 15.0 -------------------- 'Absorptivity: •0.70 Sketch of Construction Assembly. Roughness: Stucco, -Wood Shingles ASSEMBLY.0-VALUE Th. R -Value Construction Components Fr (in) Cavity Frame Outside Air Film --------------------------- ---------- ------0.17-----0-17- 1. Gypsum or Plaster Board 0.625 0.56 0.56 2. Insulation,'Mineral Fiber., R-13 • * 3.500 13.00 3.46 3: Gypsum or Plaster Board 0.500 0.45 0:45 4. 5., 6. 7. - 8. - 9. Inside Air Film 0.68 0.68 ------------- Unadjusted R -Values .14.86 5.33 ADJUSTMENT FOR FRAMING (1 /14.86) x (0.85) + (1 /'5.3.3) x (0.15) Weight: 6.4 lb/sqft Heat Capacity 1.84 = 0.085 TOTAL U -VALUE _ TOTAL.R-VALUE _ 0.085 11.72 Weight: Heat Capacity: 12..4,lb/sqft 2.92 TOTAL.R-VALUE = 17.09 PROPOSED. CONSTRUCTION ASSEMBLY --------------------------------------- ENV -3. page'9-of'14 Project Naiue'i -:SINGLE FAMILY• DWELLINGJ --------- Date: 4/21/1993 1993 Documentation:: THOMPSON SERVICES COMPLY 2.4 User' 1615 COMPONENT DESCRIPTION Assembly Name: R=13 Wall w/1" EPS Assembly Type: Wall Assembly Tilt: 90,deg (Vertical) Framing Material: Wood Framing Spacing:. 0. C. Framing Percent:, 15.0 Absorptivity: 0..70 Sketch of Construction AssemblyRoughness:, Stucco, Wood Shingles • ASSEMBLY U -VALUE , ' -, • • R w ThR-Value Construction Components; ---------------------------- Fr ' (in) , ' Cavity Frame --------------------------------------------- Outside Air -Film,.0.17 0.17 1.'9tucco 0.875 0.17 0.17 .2. Membrane, Vapor Permeable Felt _ 0.010 0.06. 0.06 3 -('Insulation, Polystyrene, Smooth Skin 1.000*' 5.00 .5.00 4'., Insulation, Mineral Fiber, R-13, * 3.500 13.00 3.46 5..,Gypsum or Plaster Board :0.500 0.45 0.45 6. 8.. 9- .. . . Inside .Air ' Film ------------------- ----------------------------------------------- 0.68 '0.68 ---------, Unadjusted•R-Values 19.5.3. .10.00' ADJUSTMENT FOR FRAMING (1 /.19.53) x (.0.85) + (1 /10.00) x (0.15) = 0.059 TOTAL U -VALUE = 0 059 Weight: Heat Capacity: 12..4,lb/sqft 2.92 TOTAL.R-VALUE = 17.09 ADJUSTMENT FOR FRAMING - /41.13) x'(0.90) + (:1 /15..47) x (0.10) Weight: Heat Capacity: 9.4 lb/sgft 3.00 4 " 0.028 TOTAL U -VALUE _ TOTAL R -VALUE = k PROPOSED CONSTRUCTION=ASSEMBLY ENV -3 page-A0'of 14 _.-------------------------------_-- Project Name: SINGLE FAMILY DWELLING Documentation: THOMPSON SERVICES lDate:,4/21/1993 'COMPLY 24 User 16,15 COMPONENT DESCRIPTION Assembly'Name: R-38 Roof(R.38.2x14.16) Assembly Type:..Roof Assembly Tilt: 22 deg (Tilted Up) Framing Material: Wood. Framing Spacing: _" O. C. } . Framing Percent: 10.01% ----------------------- Absorptivity,: 0.70. ------------ Sketch:of Construction Assembly' Roughness: Concrete,'Asph.'Shingles ASSEMBLY U -VALUE - - � :Th - R -Value Construction Components Fr (in,) Cavity Frame Outside.Air Film ----------------------------------------0.17-----0.17 1. Roofing, Asphalt Shingles 0.250 0.44 0.44 2., Membrane,.Vapor-Permeable,Felt 0.010 0.06 0.06 .3. Plywood 0.500 0.62- 0.62 4- Air Space , * 1.750. 0:77 1.73 "5- Insulation, Mineral Fiber, R-38 * 11.500 38.00 11.39 6. Gypsum.or Plaster Board 0.500 0.45 0.45 7. 8. 9 Inside Air Film 0:61 0.61 Unadjusted R -Values 41.13 15.47 ADJUSTMENT FOR FRAMING - /41.13) x'(0.90) + (:1 /15..47) x (0.10) Weight: Heat Capacity: 9.4 lb/sgft 3.00 4 " 0.028 TOTAL U -VALUE _ TOTAL R -VALUE = 0.028 35.28 r y k 0.028 35.28 r y • PROPOSED CONSTRUCTION ASSEMBLY ,`, ENV -3 ,page'11fof 14 ------------------------------------------- Project Name: SINGLE.FAMILY DWELLING JDate: .4/21/1993 -Documentation:-THOMPSON SERVICES COMPLY 24 User 1615 COMPONENT DESCRIPTION Assembly Name: Solid Wood Door ---------------------------- = Assembly Type: Door Assembly Tilt: 90 deg (Vertical) Framing Materiali None Framing Spacing: O.C. Framing Percent: 0.0:% Absorptivity: 0.70 .Sketch of Construction Assembly Roughness: Glass, Paint on Pine ASSEMBLY U -VALUE Th R -Value Construction Components. Fr (in) Cavity Frame -------------z ------------ --------------------0.17-------17- Outside Air Film 1. Softwood, Douglas Fir -Larch 1.750 1.73 1.73 2' 3. 4., 5. 6. 7. Inside Air Film 0.68 0.68 ------------------- Unadjusted R' -Values 2.58 2.58 ADJUSTMENT FOR FRAMING (1 / 2,.58) x (1.00) + (1 /'2.58) x (0.00)' _ Weight: 5.1 lb/sgft' Heat Capacity: 1..99 0.387 TOTAL U -VALUE TOTAL R -VALUE = 0.387 2.58 HVAC.ZONE.HEATING & COOLING LOAD SUMMARY page 12 of 14 ------------------------------------- ------------------------------ Proj�ect Name: SINGLE FAMILY DWELLING Date:: 4 21 1993 I JDocumentation: THOMPSON SERVICES COMPLY 24 User 1615 HVAC ZONE DESCRIPTION HVAC'Zone Name: ENTIRE HOUSE Heating System Name: RHEEM RPND7048J*. Cooling Sy stem. Name: System Multiplier: 1 Fan Schedule: 24 Hr Fans STD Peak Load Method: COINCIDENT Relative Humidity: 50 $ SPACES IN THIS ZONE PEAK SINGLE FAMILY DWELLING (Jan 12am) UNCONDITIONED GARAGE (Jan 12am) TOTAL SPACE LOAD Duct Gains &`Losses: Return Air Lighting Gain TOTAL SYSTEM LOAD SYSTEM OUTPUT AT DESIGN CONDITIONS 34227. 3648.0 7130 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note -that Sensible and Latent Cooling Loads are indicated to.allow for accurate comparison with manufacturer's output data. COOLING HEATING PEAK SENSIBLE . ' LATENT 36460 (Aug 2pm) 30843 1117 0 (Aug 2pm) 0 0 36460 30843 1117 729 617 0 37189 31460 .1117 SYSTEM OUTPUT AT DESIGN CONDITIONS 34227. 3648.0 7130 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note -that Sensible and Latent Cooling Loads are indicated to.allow for accurate comparison with manufacturer's output data. RESIDENTIAL SPACE HEATING LOAD SUMMARY ------------------------------------ page 13�,of 14 Project.Name: SINGLE FAMILY DWELLING Date: 4/21/1993. ------ Documentation: THOMPSON SERVICES ------------------- COMPLY 24 User. 1615 Name: SINGLE.FAMILY DWELLING Design Indoor Dry"Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb•Temperature: 29 F. • Design Temperature Difference: 41 F" Conduction, Area •U -Value TD Btu/hr R"13 Wall w/1" EPS ------ 1517.0 x -------- 0.0585 ---- x 41.0 --- = 3639 R-13 Wall (W.13.2x4.16) 276.0. x 0.0853 x 41.0 _ 966 Solid Wood Door 40.0 x 0:3872 x 41.0 = 635 Std Double Pane (Mtl). 248.0 x '0.7500 x,41.0 = 7626 R-38 Roof(.R.38.2xl4.16) 1818.0 x •0..02.83 x 4.1.0 = 2113 Slab.on Grade Perim 41.0 x 43 = 1763 Slab on Grade Perim =. 17.6.5. x 43 _ 7590 "Infiltration: 1.00'x 0.018 k''1818 sf• x 10.0' -ft x 1.00 AC x 41.0 = 13411 Ventilation: 1.080 x-i',1818-sf x 0.0 cfm / 333.0.. x 41.0 = 0 .TOTAL HOURLY HEAT LOSS FOR SPACE 36460 Heating AirFlow: 36460 Btu/hr / [1.08 x °35 F DeltaT)]'= 9b5 cfm RESIDENTIAL SPACE COOLING LOAD SUMMARY page 14 of 14 ------------------------------- ---------- Project ---- ------------------ Project Name: SINGLE FAMILY DWELLING Date: 4/21/1993 Documentations, THOMPSON SERVICES ICOMPLY 2:4 User 1615 Space. Name: SINGLE FAMILY DWELLING Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer -Dry -Bulb Temperature: 112 F .Design Temperature Difference: 3:4 F Conduction Area U -Value DETD Btu/hr ; R-13 Wall -w/1" EPS 1517.0 x 0.0585 x,29.6 = 2627 R-13 Wall (W.13.2x4.16) 276.0 x 0.0853 x 29.6 _ 697 Solid Wood Door 40.0 x 0.3872 x 29..6 = 458 Std Double Pane (Mtl.) 248..0 x 0.7500 x 34.0 = 6324 -R-38 Roof (R. 38.,2x14.16).. 1818.0 x 0.0283 x 50.0 = • 2577 Infiltration: 1.00 x 0.018 x 1818'sf x 10.0 ft x 1.00 AC x 34..0 = 11122 Ventilation: 1..080 x 1818 sf x 0.0,cfm / 333.0 x 34.0 0 Shaded Unshaded Solar Gain Orient. Area, SGF" Area SGF SC --------------------- _ Std Double Pane Mtl) North [ __ _ _ _ 0.0 x 15 + _.__ 92.0 x 1;5], x 0.71 = 975 Std Double Pane :''lMtl) Mtl, North [ 0.0 x.15 + 20.0 x 15] x 0..40 = 121 Std Double Pane' Mtl;East [ 5.8 x 15 + 30.2 x 73],x 0.71 =,'1621 Std.'Double Pane South [ 37.4 x 15 + 14.6 x.32] x 0..71 = 726 St& Double Pane. l) West [ Mfl 18.8,x 15 + . 5.2 x 73] x 0.77 = 507• Std:Double Pane West [ 13.8 x 15 + 6.2•x 73].x 0.40_ 266 Std.Double Pane ,(Mt West, [ 0.0 x 15 + .4..0-x 73],x 0,.73 = 213 Internal Gain r Op Frac. Area Heat Gain• Conv. Lighting' ------------ 1.00 ------ x •1818.0 x -------- 0.200 x 3.413• = 1241• Equipment;' ••1.00 x -1818.0 x 0.100 x 3.413 _ 620 Occupants' 1.00 x 1818.0' x 225 / 333 1228 TOTAL HOURLY -SENSIBLE HEAT GAIN FOR SPACE 30843 .Latent Gain- Op,Frac. Area- Heat Gain Conv. .'Btu/hr' - Equipment ---------- 1.00 ------ x 1818.0 x --------- 0.000, x ----- 3.413 = ------ 0 Occupants 1.00 x 1818.0 x 225 / 333 = 1228 Inf'ptration: 1.00;x 0.018 x 1818.sf x 10.0 ft x 1.00 AC x -0.3 _ Ventilation: 1.080 x 1818 sf x 0.0 cfm / 333.0 x -0.3 .-102 -0 .TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 1117 Cooling AirFlow: Installation Certificate: Residential CF -6F Use of this form to satisfy the requirements of" Administrative Code Is optional, but the Information must be provided nd postec Site Address Permit Number An installation certificate is required to be posted at the building she prior to the issuance of the occupancy permit. This form may be used to meet these requirements. All appliance categories listed below are the actual equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better than the appliance specified on the Certificate of Compliance (CF -11R). This certificate (or its equivalent) shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS Note: Hydronic boiler information is entered here. Other hydronic or combined hydronic equipment is listed under Water Heating Systems. Heating. Equip. CEC Certified Actual Distribution Duct or Heating Load Heating Type (furnace, Manuf. Make & Efficiency Type and Piping Before Over- Equipment heat pump, etc.) Model Number (AFUE etc.) Location R-VValue Sizing (Btuh) Capacity (Btuh) =EIkyF()ry)F, AACEM 31 G4L1.FLEX S,a 'it�SCG 3StCr:,_, �AC.rk,E RPNCC�ti3T _ STT1�. ' Cooling Equip. Type (air cond., heat pump, etc.) NCQTed, Is P CEC Cortff led Compressor Unit Actual Distribution Duct or Manuf. Make & Efficiency Type and Piping Model Number {SEER) Location R-VValus KNEE • , 00 GLASS FLEX 5, 2 RP(J�(')rl3S The building design heat loss and design heat gain rate have been determined using a method specified in Section 1S0(h) of the En y Effi ' cy Standards, and are two of the criteria used for equipment sizing and selection. in s� Signature Date HVAC Subontractor (Co. Name) or General Contractor or Owner WATER HEATING SYSTEMS Water Heating CEC Certified System Type Manuf. Make & stora a gas, etc.) Model Number Energy' Rated' Tank Factor or Input (kW Capacity Recovery or Stuh) (nallonsl EHir_lanew External Tank Insulation R -Value For small gas storage (rated inputs 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input *75,000 Btwbr), list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency. For Instantaneous electric water heaters, list Rated Input. FAUCETS & SHOWER HEADS All faucets and showerheads installed are listed in the Commission's Directory of Certified Faucets and Showerheads, pursuant to Title 24, Part 6. Subchapter 2, Section 111. ►�'? A c5,- ' �' x,/993 1 ' Signature Date Plumbing Subcontractor (Co. Newor General Contractor or Owner Revised January 1992