Loading...
BLDG (0211-163) + RPL (9871) + SFD (9889)53760 Avenida Madero 0211-163 9871 9889 LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will.do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals' Code). ( )' I am exempt under Section B&P.C for this reason 'date 4 8'H 10 "t, Signature of Owner WORKER'S COMPENSATION" DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( .) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). (y) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of tSection 3700 of the Labor Code, I shall forthwith comply with those proviisions.' Date: I it )+ `ice Applicant— Warning: . ' Warning: Failure to secure Workers Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize?representatives of this City to enter upon the above-mentioned property fc inspecti `n purposes. t Signature (Owner/Agent) F Date 4f ISO • BUILDING PERMIT PERMIT # DATE axe VAVUATION uAe : . xii LOT TRACT JOB SITE ADDRESSD-%i APN OWNER CONTRACTOR / DESIGNER / EN (NEER LA QUINTA CA 92,253 USE OF PERMIT r' 561,F. 5' OARDMN WALk, M TY ST.'iia'fOAR,1a `7C XsA [ g3 Cob -T orl m-mmucrioa"i 1,212.40 CON STRW CTI O R RX, 101-000-4-18-000 $31-00 D Q p NOV 2 2 2002 CIN OF LA QUINT FINANCE DEPT A x iJ> -TU'}: AL C'Ok3 . ` `.f. UMION AND PLM CTWY, $31.00 .. 30,00 s c RECEIPT DATE ^ { i BY D FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans OX to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs -U Electric Bond Footings Main Drain Bond Beam / Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans OX for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/ Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by,property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of variuus trades that you plan to subcontract, you•should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for, the entire project, and' such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as.an employer,and you are subject _ _. to several obligations_ including_Sta[ece_and_Fe 41- ncome_tax.,withholding, federal -social ;security -taxes, worker's__- .._. compensation insurance, disability insurance costs and "unemployment compensation,contributions... There may. be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if -you wish, the U.S. Small Business Adminstration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/ Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. , Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 QP) -7y-7012 AX (7 0) 777 11 O ER'S SY.GN9TURE/DATE '53- PROPERTY ADDRESS PERMIT NUMBER(s) IOU Of ' P.O. BOX 1504 ((1 N O . 9871 ; Building '"'" 7&105 CALLE ESTADO , ' _ Address 53760 Madero LA QUINTA; CALIFORNIA 92253 Owner Jean Ortiz • Mailing BUILDING: TYPE CON ST. OCC: GRP. Address P. O. • Box 59 A.P. Number City Zip Tel. ..La Quinta 92253- 564•-1486 Legal Description Contractor Project Description Gefteral Contract Mgmt : - Address POOL 0my P. 04' -Box 59 ' City Zip Tel.: LaQuinta 1.92253 564-1486 State Lic. City & Classif. •524325 Lic. # 1235 Sq. Ft. No. No. Dw. Size Stories "Units Arch., Engr.,' . Designer New ❑ Add ❑ . Alter ❑ Repair ❑- Demolition ❑ Address Tel. City :• : Zip State ;., Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section } ._.7000) of Divislon.3 of the Business and. Professions Code, and my license is in full force and r effect SLGNATURE DATE F _ ' OWNER -BUILDER DECLARATION Estimated Valuation' • T hereby affirm that I am exempt from the'Contractoes License Law.for the following . :7600. 0 0 w reason: , (Sec. 7031.5,Business' and Professions Code: Any city or county which requires a' .=r`permlt to construct, alter—improve, demolish, or repair any.structure, prfor to its issuance alsoF AMOUNT ':requires the applicant for such permit to file a signed statement that he is licensed pursuant to _ PERMIT ` dia provisions o/ the Contractor's License Law, Chapter.9 (commencing wlth.Section. 7000) o/ Divlslon 3 of the Business and Professions Code,- or that. he is exempt therefrom, and the basis 'tor:-the•alleged exemption. Any violation of.Section 7031.5 by.'any applicant for a permit_ - Plan Chk. Dep.• 'r subjects the applicant to'a civil penalty o/ not more than five hundreddollars.($500). -. plan Chk. Bal. O'1, as owner of the property, or my employees with wages as their sole. compensation, will '-. _ - do the work, and the structure is not intended or offered for sale. (Sec 7044, Buisness and 'Const. 90 .,00 Professions Code: The Contractor's License Law does not apply. to an owner of property who builds or If n improves thereon and who does work. -himself *or through his own employees, Mech. ' .. Q'0 provided that' such improvements are not intended or offered for sale. If, however, the building or improvement 1ssold within one year of completion,Ahe owner-builderwill have the burden ' Electrical .`30 0 of. proving that he did not build or Improve for'the'purpose o/ sale.) - M1 ,O I, asownerof the property, am exclusively contracting with licensed contractors to con- Plumbing 21. 00 •struct the project. (Sec. 7044, Business'and Professions Code: The Contractor's License Law does not apply to an owner of property:who builds or improves thereon, and who contracts for . S.M.I.- such projects with a contractor(s) licensed pursuant to the Contractor's License Law.). _ .O t am exempt under Sec. - B. 8 P.C. for this reason Grading . Driveway Enc. Dale Owner Infrastructure WORKERS' COMPENSATION DECLARATION 1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of Wo rker's,Compbnsation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code:) Pollcy No. h '`- Company O_Copy is filed with the city. O`Certified copy is hereby furnished. TOTAL CERTIFICATE OF EXEMPTION FROM REMARKS .WORKERS' COMPENSATION INSURANCE - (This section need. not be - completed if the permit is for one hundred dollars ($100) valuation n0.ra nrr t o •+c A >, /:.•1 k.q`_.L14 • 6 +, or less:) v „ g I certify that in the performance of the work for which Ahis permit is issued, I -shall not 0. L.Y7 } C , ?( . =any person in any'manner so -as to become'subject to the Workers' Compensation .4 Laws of California. . Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should .become ZONE: ''BY: - - subject to the Workers' Compensation provisions of the Labor Code, you must forthwith 1. - comply with such provisions or this permit shall be deemed revoked. " • Minimum Setback Distances: ' •\ , Front Setback.from Center.Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line ' 'I hereby affirm that there is a construction lending agency for the performance of the work for which this permitis issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This Is a building permit when properly filled out, signed and validated, and is subject to expiration If work thereunder is suspended for 180 days: I certify that 1 have read this application and state that the above information'is correct. Issued by: Date Permit' A agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives •of this 'city to enter the above•. ? ' mentioned property for inspection purposes. Validated by: Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ 2ND FL. SO. FT. @ POR. SO. FT. ® GAR. SO, FT. ® CAR P. SO. FT. [cp WALL SO. FT. ® SO. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation ROUGH PLUMB. FLOOR DRAIN MECHANICAL FEES HEATING (ROUGH) WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER DUCT WORK GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GAS (ROUGH) LAUNDRY TRAY AIR HANDLING UNIT CFM HEATING (FINAL) KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ®c BATH TUB BOND BEAM SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 Vi c SEWAGE DISPOSAL LUMBER GR. SO.FT.GAR ® 3Vic HOUSE SEWER FRAMING FINAL INSP. GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPIEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING /► ' ✓l (// REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING,/ %! MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL P.O. BOX 1504 itN u . 9882 Building 78-105 CALLE ESTADO Address 51-760.Madero LA QUINTA, CALIFORNIA 92253 ka Owner Gene Ortiz BUILDING:- TYPE CONST. OCC: GRP.. Mailing , , • • Address ' P. O.—Box 59 A.P. Number . 774--:143-001 City Zip Tel._. - .. 3.aQuinta " 92253 564-- 486 Legal Description fl$ .0 24. Block- 1.98 - Contractor 1 -'- Ib>id i ` ..gact Mgmt a Project Description 8PD ' Address P. 0. IROS:, 59, - T City. Zip Tel.: , ... LaQui,z32253 State Lic. City. & Classif. 524325 Lic. # 1235' Sq. Ft. 1641 No. No. Dw. Size Stories Units Arch.; Engr.; 'DesignerNew ❑ Add ❑ Alter ❑ Repair 0 Demolition.O Address Tel. Pe=ii, does nbt iTaC,I ude - bloc wall or.. City Zip State pool Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencingwith Section 7M"' 7000)•of Division 3 of the Business and Professions Code, and my license is in full force and effect.. " , SIGNATURE DATE OWNER-BUILDER DECLARATION Estimated Valuation I hereby affirm that L am exempt from the Contractor's License Law for the following $ 908.50 . -;reason: '(Sec. 7031.5,Susiness and Professions Code: Any city or county which requires a permit to construct, atter, Improve,. demolish, or repair any structure, 'prior to itsissuance also AMOUNT requires. the applicant for such permit to file a signed statement that he is licensed pursuant "to PERMIT - the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 30 IF the Business and Professions Code, of that. he is exempt therefrom, and the basis for the alleged exemption. Any violation. of Section 7039.5 by 'any applicant .for a. permit '.Plan Chk. Dep. ,..: - - - . , 250.00 _ subjects the applicant to a civil penafty of not more than live hundred dollars.($500).. • - ••_ • '•• O I, as owner of the property, or my employees with wages as their sole compensation,•willPlan Chk. Bal.. 2M.30 do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and COr1St, r Professions Code: The Contractor's License Law does-not apply to an owner.ol property who - 626..0a►0 builds or improves thereon and -who does such work himself or through his own employees, Mech. provided that such. improvements are not intended or offered.for. sale. If, however, the building + - • sir or improvement Is sold within one-year of completion, the owner-builder will have the burden "Electrical; ' of proving that he did not build or improve for the purpose of sale.) - . ' n . 3n ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing Z ° o J i' struct the project. (Sec.. 7044,• Business and Professions Code: The Contractor's. License Law.. does not apply to an owner of property *who builds or improves thereon,, and who contracts for - S:M.L' 9.,v 70 'Such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) - ' 0 I am exempt under Sea Grading. 20.;00 B. 8 P.C. for this reason - , Driveway Enc. 20.00 Date Owner _ _ Infrastructure 2095.03 WORKERS' COMPENSATION DECLARATION. I hereby affirm, that I have a certificate of consent to self-insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ' CoIs filed with the cit . • 0 Certified py y copy is hereby furnished.. TOTAL 3626.87 3.376+.87 ` CERTIFICATE OF EXEMPTION FROM REMARKS • WORKERS' COMPENSATION INSURANCE (This section need not be-completed ff.the permit is forone hundred dollars ($100) valuation or less.) 1 certify that In.the performance of thg work for which this permit is issued,.I shall not employ any person in.any manner so as tc,become subjec,C to thes.Wor sy_Compensation f uF ; 1 t y Laws of California. M "--' "" `y t, Date f"9 = t Owner" — . :t r `. , qtr . •`1" 2 "+1 `7 NOTICE, TO APPLICANT: If,. after making this' Certificate of Exemption -should' become ZONE:'-'- subject :to the Workers' Compensation•-provisloris-of the Laboi Code, yoq must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked. - - . - - Front Setback from,Center Line Rear Setback from Rear Prop. Line - CONSTRUCTION LENDING-AGENCY Side Street Setback from Center Line 'I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec, 3097, Civil Code.) • Side Setback from Property Line ' Lender's Name Lender's Address + This is a building permit when properly filled out, signed and validated, and is subject to, FINAL DATE INSPECTOR expiration it work thereunder is suspended for 180 days: y I certify that .I have read this application and state that the above, informatiorris correct: Issued by: Date permit'- - I,'agree to comply with all city and county ordinances and state laws relating to building construction, and hereby "authorize representatives ,of this city to enter the above-. mentioned property for Inspection purposes. Validatedby: Signature of applicant Date Mailing Address Validation: City, State, Zip Y CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SQ. FT. ® $ 2ND FL. SQ. FT. POR. SQ. FT. ® GAR. SO. FT. ® CAR P. SQ. FT. WALL SQ. FT. ® SQ FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation SLAB GRADE FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED ROUGH WIRING. LAUNDRYTRAY AIR HANDLING UNIT CFM FOUND. REINF. KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1+/. c SEWAGE DISPOSAL SERVICE SQ.FT.GAR ® 3/ac HOUSE SEWER BOND BEAM GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK Vg -6 / GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE Z ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING. DUCT WORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM ' GRADING cu. yd. $ plus x$ _$ LUMBER GR. FINAL INSP. 1 /tfl FRAMING /Q/ 9 FINAL INSP. ROOFING/ J L c.'/ t /O//J REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND Q FINISH GRADING FINAL INSPECTION // CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT - 82-879 Highway.111 NOTICE: Indio, CA 92201 Document Cannot Be ,Duplicated (619) 347=8631 Date 8/13/91' Type of Permit I La Quinta No. 10802 Permit # Owner Name Log # Gene Ortiz No. 53760 street Avenida Madero city La Quinta zip 92253 Study Area 111 APN # 774-143-001 Tract # I I Lot # Square Footage 1641 Type of Development . Single, Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under '500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school. fees at this time due to the following reason: EXEMPTION NOT APPLICABLE - This certifies that school facility fees imposed pursuant to 'Government -Code 53080 in the amount of 1.58 X 11.6417 or$ 2,592.78 have been paidito D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this.square footage in this proposed project may now be issued. Fees Paid By Jean M. Ortiz-TTEE Telephone 564-1486 Name on the check By James E. Lively r Assistant Superintendent, Business Services Fee collected /exempted by Shelley D. Bennett i 4 Paymert: R2ceivvd, '; Signa tore i k ChecL' i4 ' 109 g Collector: Attach a copy of county or city plan check application form to distri t`^ py for ail waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting j , CALVIN C. KAMINSKAS i s A f a DAN RILEY Sealer. Welghls & Measures Assistant Commissloner 7 V ' (714) 275-3030 (714) 275.3000 OFFICE OF AGRICULTURAL COMMISSIONER JAMES O. WALLACE, commissioner 83-612 Avenue 45 Suite 7 Indio, CA 92201* (619) 342-8291 DATE U ) J 2 3 °( q( CASE NO. PL D O% 2 9 1 M t ' DEVELOPER'S NAME : G P✓1 t'' "u I O ' T' C I / ' A t oxye Q-v ADDRESS : TELEPHONE: /Q • 2(% /mac Dear Developer: After reviewing your landscaping plans, all plant material listed is not in violation of quarantine laws governing the Coachella.Valley.. If substitutions . do occur and they differ from plant material listed, this office must be notified immediately: Thank-you for protecting and preserving. the Coachella Valley's pest-free environment. Agricultuy6l Conmi sioner's Office I cc: Indio and Riverside 4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92501 — FAX (714) 275.3012 TRUSS D.[V.ISION 5 TON MBER.co -9754, fit'• CaUbrrdg 9=li(sl 9) 347 `ft E. LEorl St nlic,Y tii I e t:n r b I); I Ii.E UI co•a nS;Rr..tn , - , s AGRICUL I URAL y OMMISSKOILIt LASTS U WAUA T , AND CEEMEvI I1F,'VEMSIE t. VI:IGI i 1 S b hl - AsuIILS s uin 69-613 Ilt+y 06, 1)ulte II -12 •cuttchelltt, CA 92236 • i; r9 'sa 619-J42-0'l9l . CASs I IU L, i2 111 UNCE: I)CVF,WI'CIt' S IIN•ICs n1,1,1tCss - I.. n1 .A- S `•( . ISS • 53 vS Dear Develuveri After reviewlnq your 1010SCO111.ncl plasm, till Ill nt nylerial listedCIS su stitutliulls violation of yuatantlne ltlws tluveinlny ll;e Cuacllella Valley. do occur and they dlE[er [tun I;lanl n►alel:lal listed, tills o[Eice must he nuLlEled hill>ediately. ervlliy the Coachella Valley's pest -free envitvlrlent. '1'Iiauilc you [or ptvtectLiy and 1►ies . ngr ultural Cain ss oiier s UL [ ice ccli lndio slid 111veirside U[ [ ice NOTE$: 1. Cul ail memoen to bear. 2. Gertner an out.4 on born sloes of io%m un lose X or Y \outlons ■re soecAmo. 3. The t V" teorCator n resoor"VDte to pra, oe p.etlrp for runallng as reoa/we0. See usage i uAe, e. See Vote ]for web lateral bracing ,r \ ieouir9~111. Y Y, C6 L'J 20REIN% UXLSS r0t^D P • 6' 13;ult: a PSIL ' SPAN- L Dayn •114 ady to we sen ".Am eonanas. TAIL trust is onyned as an rbnawl Oudtley Wroortertl. a o to tc rC,,wala0 reo t bnWnn Q ocsyn Int soeco calm a me oeyna 01 Salo DuAQp 9.611cvy 1 N rtlnnUl Muss m0'naas qtly A0anm11 baCn0 01 the wer111 tIW%Oe mfr toecnea o a Wen U0001l be Imulto Fa Qerk al Quosme tK 8neno V40M Iram1. Fa soeC11K uws eaery reounernpls eomlq HYDROAIR* awry oovw For sm-Am rWj,QrV uacnm. ar14r Cannot. 110119e. celhay. ooam"bacry to Own mun"e..l►"Orvl we111- no IM f♦esir*eAM con a no-arl tww, EN01N0WR1NG,IIVC, 'arlluw( sae 1rus1 Y\,II TtsttNe 1111 Agg$ K000. hytntrille AUnuM. 20183. BOX 1759. ST. LOUIS. MO. 93171 TYPE 600 UPC CODE' 21- 011 O.C. 4/12 SLUPE PT PLATES DOUG FIR L HEM FIR 20/l0,/0/10= 40 PSF 9 1,25 ; Hrot"; ,r Enolnee,,nq. Inc 1V79 1 Design Information rc(D•L)= 30.0 PSF 5 Plating Information .., uec P.C(D-L)= 10,0-FSF . + D►G NO. R79-3010-UP2F- . 6G4 TL(D-L)= 40,0 PSF JT. MAX-SPANS(FT-IN) HYDRO -NAIL LGCATION(IN) • SHT '00. 6• DATE 3/23/79 STRESS INC = 1.25 NO. PF" 1.F PLATE SIZE •--X-- --Y - J 1 1E-11 1E- 8 2 1/2 X 4 PT 2 Maximum Chord Spans (Ft. -In.) 22- 8 27.-' 5 3 X 4 PT ' 2E- 0 2F- 0 2 1/2 X 6 PT LU48F.R GRACE TOP CHORD SOTTOr. CHORD =DOUGLAS FIR= 2X4 2X6 2X4 2X6 J 2 2h- 0 2e- 0 1 X 4 PT NO 7 2e- 0 26- 0 24- 1 28- 0 • NO 7 DENSE 29- 0 28- 0 24- 1 28- 0 SJ 2 'tH- 0 2h- 0 4 1/2 X 6 PT b 1. 1/4 NO 1 2a- 0 29- O 25- 5 28- 0 NO 1 DENSE 2d'- 0 28- 0 26- 9 26- 0 J 3 2B.- 0 2N- 0 3 X 4 PT• 3 2 1/2 SEL STRU 28- 0 28- 0 25- 5 7P- 0 DFN SEL STRU 2d- 0 2e- 0 26- 9 '28- 0 J 6 20- 0 2E- 0 2 1/2 X 6 PT =HEY FIR= NO 2 26-11 28- 0 20- 1 25-10 SJ -6 20- 0 28- 0 4 1/2 X 6 PT 1 1/4 NO 1 28- 0 28- 0 21- 5 27- 5 SEL STRU 28- 0 28- 0 21- 5 27- 5 CHORD SPLICE OPTIO14S •REOUIRES 2X6 BEARING vREOUIRES 2X8 BEARING C 2 28- 0 2E-, 0 3 X 4 PT C 6 28- 0 21- 0 3 X 4 PT PLATES MARKED + NVOUIPE 2X 6 CHORDS 3 Web Requirements (FL -In.) GROSS -PLATE RATING(YSI) FOM P1=171 (UF), 1690-F) . U149HACEU BRACED 2X4 WFBS W1 W2 '41 W2 STD -DF 28- 0 28- 0 28- U 26- 0 CDN -DF 2B- 0 28- 0 28- 0 2H- 0 STU-FF 2P- 0 2H- 0 28- 0 26- 0 CCN -►'F 26- 0 2P- 0 28- 0 28- 0 2X6 WEBS N07 -DF 2P- 0 28- 0 NO2-MF 28- 0 78- 0 4 Force Information L=Span ( FL) CHORn FORCES WEB FOMCES JOINT LOADS C 1= -84.7L W'1= -21.96 J 1= 13.3L C 2= -63.26 W 2= 26.5L J 2= 15.1L C 6= '80.4L J 3= 13.6L REACT= -40.OL J 6= 10.1L DESIGNED IN ACCORDANCE WITH TPI -78 AND NC5-77 NOTE$: 1. Cul ail memoen to bear. 2. Gertner an out.4 on born sloes of io%m un lose X or Y \outlons ■re soecAmo. 3. The t V" teorCator n resoor"VDte to pra, oe p.etlrp for runallng as reoa/we0. See usage i uAe, e. See Vote ]for web lateral bracing ,r \ ieouir9~111. Y Y, C6 L'J 20REIN% UXLSS r0t^D P • 6' 13;ult: a PSIL ' SPAN- L Dayn •114 ady to we sen ".Am eonanas. TAIL trust is onyned as an rbnawl Oudtley Wroortertl. a o to tc rC,,wala0 reo t bnWnn Q ocsyn Int soeco calm a me oeyna 01 Salo DuAQp 9.611cvy 1 N rtlnnUl Muss m0'naas qtly A0anm11 baCn0 01 the wer111 tIW%Oe mfr toecnea o a Wen U0001l be Imulto Fa Qerk al Quosme tK 8neno V40M Iram1. Fa soeC11K uws eaery reounernpls eomlq HYDROAIR* awry oovw For sm-Am rWj,QrV uacnm. ar14r Cannot. 110119e. celhay. ooam"bacry to Own mun"e..l►"Orvl we111- no IM f♦esir*eAM con a no-arl tww, EN01N0WR1NG,IIVC, 'arlluw( sae 1rus1 Y\,II TtsttNe 1111 Agg$ K000. hytntrille AUnuM. 20183. BOX 1759. ST. LOUIS. MO. 93171 TYPE 600 UPC CODE' 21- 011 O.C. 4/12 SLUPE PT PLATES DOUG FIR L HEM FIR 20/l0,/0/10= 40 PSF 9 1,25 ; Hrot"; ,r Enolnee,,nq. Inc 1V79 ENERGY CONSULTING GROUP 'III Indian Hills Box 34F Lic 473969 W Mountain Center, CA 92361 The following.are some explanatory notes concerning the enclosed forms: C2R The compliance margin is a positive number --the building, as described in these reports, complies with the California Energy,Commission requirements.. CF -1R Page 2 should be signed by the building designer and owner. Please note any remarks that may appear in the "Special Features/Remarks" section. These components are required standards for your build- ing. Also, the brand name and model number of the furnace, air conditioning and hot water systems you plan to install should be'entered. MF-lR Lists the mandatory items required by the California Energy Commission and should be completed by. -the r builder or owner. HVAC SIZING calculations are used to indicate the basic heating and air conditioning requirements.(Btu) for your particular building. Please note that this is. a guideline and the person selecting this equipment. needs to consider all factors involved (.such as -air flow restrict.ions-,.safety margi.,ns, etc.) when makng'these choices. Please contact us i.f you have any questions concerning this compliance package. Thank you; W. J. Fi-nnell Enclosures r Residential & Commercial Energy Consultants 1-800-262-9966 COMPUTER METHOD SUMMARY Page 1 C -2R Project . Title.. . ..­­MEDERO Date........ 07/22/91 Project Address... .. 53763 MEDERO ---------------- LA QUINTA Documentation Author...'W J FINNELL ; Building Permit # Company ............... Energy Consulting Group P Y• Telephone.............. 800-26279966 i Plan Check / Date Compliance Method..... MICROPAS3 by Enercomp', Inc. ; Field Check/ Date - Climate Zone..... 15 ----------------:--- ' MICROPAS3 v3.11 -File-MEDERO Wth-CTZ15 Program -FORM C -2R User#-MP1325 User -Energy Consulting Group Run-MEDERO ----------------------;-------------------------------------------------- MICROPAS3 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design ---------- Design ----------- Margin - ---------- _ ------------------------ - Space Heating.......... .6.86 3.95 2.91 = = Space Cooling. ........ 49.39. 43.84 5.55 = = Water Heating.......... 11.40 16.55 -5.15 = _ - Total 67.65 64.34 3.31 = _ ***.Building complies.with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 1641 sf Building Type.... Single Family Detached Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Building,Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade (Package D) Number of Building Zones.:.. 1 Conditioned Volume......... 16592 cf Footprint Area............. 1641 sf Slab -On -Grade Area......... 1641 sf Glazing Percentage......... 16 % of FA Average Ceiling Height..... 10.1 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Special Cond- Area Volume Dwell Thermostat Height Vent Area Zone Type itioned ( sf ) ( cf ) Units Type (ft) (sf) HOUSE Residence Yes 1641 16592 .1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title ............ -MEDERO---------------------- -_--- Dat e----- ......... ---07/22/91 MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM C -2R User#-MP1325 User -Energy Consulting Group Run-MEDERO OPAQUE SURFACES Area --------------- U- Insul Act Solar Location/ Form 3 Surface, (sf) value R-val Azmth'Tilt Gains Comments Reference HOUSE 1 Wall 409 0.065 R-19 .0 90 Yes OUTSIDE None 2 Wall 307 0.065 R-19 90 90 Yes OUTSIDE None 3 Wall 257 0:065 R-19. 180 90 Yes OUTSIDE None 4 Wall. 197 0.065 R-19 180 90 No GARAGE None 5 Wall 112 0.065 R-19 270 90 Yes OUTSIDE None 6 Wall 217 0.065 R-19 270 90, No GARAGE, None 7 Roof 1632 0.029 R-38 0. 0 Yes ATTIC None 8 -Door. 20 0.330 R-0 0 90 Yes OUTSIDE None 9 Door 18 0.330 R-0 270 '90 No GARAGE None PERIMETER LOSSES, -.--------------- Length F2 Insul Surface (ft) Factor R-val Location/Comments HOUSE 10 S1abEdge 31 0.900 •R-0 OUTSIDE 11 S1abEdge 9 0.550 R-0 GARAGE 12 S1abEdge 114 0.720 R -O- OUTSIDE 13 SlabEdge 33 0.500 R -O GARAGE GLAZING SURFACES . SC Interior SC Area # of Frame Open U- Act Glass Shade Gls+ Surface ----------- (sf) Panes Type Type value Azmth Tilt Only ----- ------------- ------ ----- Type Shade HOUSE ----- ---- ----- ---------- ----- 1 Window 91.0 2 Metal Slider. 0.65 .0 90 0.77 'LGT VENETI. 0.29 2 Window 55.0. 2 Metal. Slider 0.65 90 90 0.77 LGT VENETI 0.29 3 Window 75.0 2 Metal Slider 0.65. 180 90 0.77 LGT VENETI 0.29 4 Window 33.0 2 Metal Slider 0.65 270 90 0.77 LGT VENETI 0.29 5 Skylight 9.0 2 Metal Slider' 0.64 0 0 0.77 none 0.77 EXTERIOR SHADING -------------- Area ; Shading SC of Surface (sf) Type Ext Shade HOUSE 1 Window- 91.0 50% bug scrn 0.84 2 Window 55.0 50% bug scr.n 0.84 3 Window 75.0 50% bug scrn 0.84 4 Window 33 .0 . 50% bug scrn 0.84' COMPUTER METHOD SUMMARY Page 3 C -2R -------------------------------- Project Title.......... MEDERO Date........ 07/22/91 MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM C -2R User#-MP1325 User -Energy Consulting Group Run-MEDERO THERMAL MASS WATER HEATING SYSTEMS Area Thick Heat Conduct -'Surface Pilot Mass Type --------------- (sf) ------ (in) ----- Cap ivity R -value --------------------- Location/Comments -------------------------- H.OUSE Blanket iency . Loss Rating (.Btuh ) Credits Storage 1 S1abOnGrade .292 3.5 28.0 0.98 R-0.0 KITCHEN/ENTRY/BATHS 2 S1abOnGrade 1349 3.5 28.0 0.98 R-2.0 REST OF HOUSE 3 InteriorHorz 66 1.,0 24.0 0.67 R-0.0 tile: kitchen & baths 4 InteriorVert 100 4.0 21.0 0.59 R-0.0 LIVING ROOM HVAC SYSTEMS .Minimum Duct Duct Duct System Type Efficiency Location. R -value Efficiency HOUSE Gas 0.800 SE Attic R-5 0.828 AirCond' 9.50 SEER Attic R-5 0.818 WATER HEATING SYSTEMS Capa- R-12 or Pilot System # of city Greater Effic- Standby Input Size Type Heat ( gal ) Blanket iency . Loss Rating (.Btuh ) Credits Storage Electric 1 36 Yes 0.99 RE .93% 5.5 kW n/a Recovery SPECIAL FEATURES/REMARKS ------------------------- CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... MEDERO Date.......... 07/22/91 Project Address.. ... 53763 MEDERO LA QUINTA Documentation Author... W J FINNELL ; Building Permit # Company ................ Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check / Date Compliance Me.thod...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 --------- ------- - ---------------------------------------------- MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM CF -1R User#-MP1325 User -Energy Consulting Group Run-MEDERO ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area...... .1641 sf . Building Type .............. Single Family Detached Building Front Orientation. Front Facing 0 deg (N) Number of Dwelling Units... 1 Number of Stories.. 1 Floor ConstructionType...:. Slab On Grade (Package D) Infiltration Control...... Standard BUILDING SHELL INSULATION Component Insul Type R -value Location/Comments Wall R-19 OUTSIDE, GARAGE Roof R-38 ATTIC Door R-0 OUTSIDE, GARAGE S1abEdge R-0 OUTSIDE, GARAGE GLAZING Glazing Area Thickness Area # of Interior Exterior (in) --------- Framing Orientation S1abOnGrade (sf) Panes Shading Shading Overhang Type Window. Front (N) 91.0 2 LGT VENETi ------------- 50% bug scrn ----------------- None Metal Window Left (E) 55.0 2 LGT VENETI­50% bug scrn None Metal Window Back (S) 75.0 2 LGT VENETI 50% bug scrn None Metal Window Right (W) 33.0 2 LGT VENETI 50% bug scrn None Metal Skylight Horz 9.0 2 none None None Metal THERMAL MASS Area Thickness Hard Surfaced/ Type ------------ .(sf) ------ (in) --------- Exposed Location/Comments S1abOnGrade 292 3.5 -------------- Yes ------------------------ KITCHEN/ENTRY/BATHS S1abOnGrade 1349 3.5 No REST OF HOUSE. InteriorHorz 66 1.0 Yes tile: kitchen & baths InteriorVert 100 4.0 Yes LIVING ROOM CERTIFICATE OF COMPLIANCE: RESIDENTIAL --------------- Page 2 CF -1R Project Title.... --=---------------------------------------------------------------------------- .... MEDERO Date....... 07/22/91 MICROPAS3 v3.11 file-MEDERO Wth-CTZ15 Program -FORM CF -1R -.-------------------------------------------------------------------------;----- User#-MP1325 User -Energy Consulting Group Run-MEDERO ASSUMED HVAC SYSTEMS, ----------------- Assumed. Duct Duct Assumed System Efficiency Location R -value Gas 0.800 SE Attic R-5 AirCond 9.50 SEER Attic R-5 ACTUAL HVAC SYSTEMS ------------------- °Actual. Output Manufacturer and Model # Actual System Efficiency ( Btuh ) (,or approved equal) Heating Cooling z. . . Cooling Coil f. CEC Maximum output for Gas Central Furnaces: 108000 Btuh WATER HEATING SYSTEMS --------------------- Tank R-12 or # of Vol Greater Manufacturer and Model # Energy System Type Heat ( gal) Blanket (or approved equal) Credits Storage, Electric 1 36 Yes' SEARS POWER MISER Recovery SPECIAL FEATURE'S/REMARKS CERTIFICATE OF COMPLIANCE= RESIDENTIAL 'Page" -3 CF -1R --------------- Project Title.......... MEDERO Date... 07/22/91 ' MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM CF-iR User#-MP1325 User -Energy Consulting Group Run-MEDERO 1 COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications -needed to comply with Title 24, Chapter.2-53'and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This .certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation, features which -vary are indicated in the'Special Features/Remarks section. DESIGNER r+WNFQ Name.... Company. Address. Phone.. License. Signed (date) DOCUMENTATION AUTHOR Name.... W J FINNELL Company.. Energy Consulting Group Address. 34F .Indian- Hills Mtn Center, CA 92361 Phone... 800-262-9966 Signed , 7)z 7- 191 (d to Name.... Company. Address. Phone.. Signed ( date ) 'ENFORCEMENT AGENCY Name..: . Title. . Agency.. R Phone... MANDATORY MEASURES'CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title... MEDERO Date........ 07/22/91 Project Address:. .. 53763 MEDERO --------------------- LA QUINTA Documentation Author... W J FINNELL ; Building Permit # Company... Energy Consulting Group Telephone......... ..... 800-262-9966 ; Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone...... .... 15 ------------ -------- MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM MF -1R , User#-MP1325 User -Energy Consulting Group Run-MEDERO ------------- ----------------- ----------------------------------------- --------- Lowr,ise' residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compl.iance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the Permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for 'the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enf:orce- er. m:ent * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. * 2-5352(c): Minimum'wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - wa-ter absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 2-5311: Insulation specified or installed meets CEC quality standards.' Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfiltration. Controls a. Doors and windows between conditioned,and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstri-pped; all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fir.eplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous ht it n i nn nac MANDATORY MEASURES,.CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... MEDERO Date........ 07/22/91 MICROPAS3 v3.11 File-MEDERO Wth-CTZ15 Program -FORM MF71R User#-MP1325 User -Energy Consulting.Group Run-MEDERO ------------------------------------------------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES --------------------------------- Design- Enforce- er ment 2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. ,2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * 2-5316(a): Ducts constructed, "installed and insulated per Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems havedamper, controls. 2-5314(0: Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment', water heaters, showe'rheads and faucets certified by the CEC. 2-5352(i): Water heater insulation blanket (R-12 or greater ), for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated to R73 or greater). 2-5312(Exception I): Pipe'insulation on.steam and steam condensate return and recirculating piping. 2-5318(d): Swimming'•Pool Heating 1: System has: a. On/off switch on heater.' b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional -,.water inlet. LIGHTING AND APPLIANCE. MEASURES Design- Enforce- er ment 2-5352(j): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the.CEC. WATER HEATING Page 1 ' ' '. | DHW =========-==== Projeot Title.''''..... MEQERO Date.....,.' 07/22/91 Project Addreoo'''''''' 53763 MEQERO ---------------- LA QUINfA QUIN A / / . DVoumentation Author... W J FINNELL ' Building Permit # / Company. Energy Consulting Group Telephone.''''''''''''' 800-262-9966 / Plan Check / Date / Compliance Method''''.' MICROPA53 by Eneroomp, Inc. / Field Check/ Date / Climate Zone'''''.''''' 15 --------------------- =============================================================================== | MICROPA53 w3'11 File-MEDERO Wth-CTZ15 Program -WATER HEATING / ' Uoer#-MP1325 User -Energy Consulting Group Run-MEQERO / -_____-___--_-_________--___-___---___-_---________-----____-__-___-__-_-___--__ WDRKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA 1' Water heater type''''''' Storage, Electric 2. Manufaoturer''''''''.''' SEARS POWER MISER 3' Model numbar'''''''.'''' 4' Ignition devloe..'''-',. n/a 5' Tank volume.''''''''''`' 36 gal 6. Recovery efficienoy~.''' .99 percent xO'01 7. Standby loss'''''',',''' '0093 percent/hour x 0.01 8' Rated Input'..''''''.''' 18771'5 Btu/hr 9.'Number of Heatero''''''- 1 1O'Inoulation Jaoket''''''' Yes B. OPERATING DATA 1. Climate Zone'''''''''''' 16 2. Water heating budget'''' 18700 kBtu/yr/unit ' 3. Tank set temp.'''''.'''. . 140 F 4' Water main temp''''''''' 70 F 5' Daily hot water load'''' 50 gal 6. Ambient air temp '..'..^' 72.6 F 7' Adj. Standby Loosee',''' '00744 8' No. dwelling unito..''.' 1 9. Pump power'...','''''.'' O Watts (O Watts controller) 1O'Pumping energy'''''-'''' O Watt-hr/yr (24 hr per day) C. WATER HEATING ENERGY CREDITS 1' Credit Name'.'''.''''''- Recovery 2. Annual saVlngs'' ''''''` 2805 kBtu/yr/unit ' D. ANNUAL WATER HEATING ENERGY 1' Recovery load''''''''''' 10539 kBtu/yr 2' Recovery enerQy''''''... 7813 kBtu/yr 3. Standby loss energy''''' ` kBtu/yr 4' Pumping anergy''''.'','' .1243 O KBtu/yr source S' Total energy'''''''''''' 27166 kBtu/yr/unit source 6' Comparioon'''.,'.''.'','' _8485 kBtu/yr/.nit source 7. Pointo''.''','''''',''''' -10 8' Water Heating Energy -Use 16.55 kBtu/yr/of (Q5 x B8) / 1641 of HVAC SIZING Page 1 Project Title.'.''''''' MEDERO Date'''''.'' 07/22/91 Project Addr000'.'.''.' 53763 MEDERD --------------------- LA OUINTA / . . Documentation Author'.'' W J FINNELL' Building Permit # / Company.''''......'-... Energy Consulting Group Telephone,_,____',__''800-'262-9966' Plan Check / Date . . Compliance Method.'.... MICROPAS3 by Enerco0p, Inc. ' Field Check/ Date / Climate Zona'.'''''..'' 15 --------------------- =============================================================================== . MICROPAS3 w3''11 File-MEDERD Wth-CTZ15 Progr m.-HVAC SIZING / | Usmr#-MP1326 User -Energy Consulting Group' Run-MEDERO i ----------- ----------------------- ---------------------------------- ___-___-__-_ ' GENERAL INFORMATION / Floor Area'''''''''.''''''' 1641 of Volume`'''''''''''' -',''''''165g2 cf ' Front Oriantation.''''''.'' Front Facing 0 deg /Nl Sizing Looation''''.'''''''' INDIO Latitude .''''','''''''^''-' 33'7 degrees Winter Outside Deoign'''''' 29 F ` Winter Inside Deoign.''''''' 70 F ' Summer Outside Deoign''''.. 112 F ' Summer'Inside Design''''''' 78 F Summer Ranga''...'''...'''. 30 F _Shadlng Used.''''''''''.'', No Latent Load Fraction'.'','' 0'20 - HEATING AND C,OOLING __-_____--_---_-__-___--___----_ LOAD.SUMMARY . ` ' . Heating Cooling Description . ----------------------------- -__ /8tuh1 ( Btuh) Opaque Conduction and Solar..'.', -,-_________ 11838 -__________ 5811 ,Glazing Conduotlon''.`''.''.'^.'' 7005 . 5809 Glazing 6mlar''''.,-'...'''.''''''' n/a 8899 Infiltrati on''''''''''''''''''.,' 9784 ' 5798 .Internal Gain.''''',''''''''' ''' n/a 5 2550 Ducts'..'_''..''.~''..''''''''.'' 863 2887 ' Sensible Load ''''.`'.''''''''.'' 314 0 31754 Latent Load.'''''''''''',''.-'''- n/a . 351 Total Load ------------ 31490 ________--_ Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment' Other relevant design factors such as air flow .requirements, outdoor design temperatures," coil sizing, availability of equipment, oversizing safety margin, etc., must also be cons'idered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. . CE,C Maximum 'Output for gas central furnaces only area weighted SE): 45000 + (100.0 w (0-800— 0.71).x 7000)= 108000Btuh