Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RER (06-2712)
53965 Avenida Madero 06-2712 P.O. BOX 1504 78-495 CALLE TAMPICO . LA QUINTA, CALIFORNIA 92253 Application Number: 06-00002712 Property Address: 53965 AVENIDA MADERO APN: 774-142-023-11 -00000.0- Application description: REMODEL - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 10000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION 4 4. BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or c that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by an applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and 'the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she *did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERAIIT VOICE (760) 777-7012 . FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/19/06 Owner: M/M B. BARRERA 53965 AVENIDA MADERO LA QUINTA, CA 92253 FRR Other.struct info SruC III Contractor: N I OCT 2 3 2006 Owner DITION 2001/2005 ----------------------------------------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for woikers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 3.00 Policy Number - - - - - - - - - - - - - - - certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section (3L 6 o377000 of the e, I shall f t with comply with those provisions. e• .,D YL Plicant: ! [ ..frpl WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person it whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under, or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this coun o enter upon the ab ve-mentioned grope r inspection MC—) ,at" at Sign a (Applicant or Agent): I Application Number . . . . . 06-00002712 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 117.00 Plan Check Fee 76.05 Issue Date . . . . Valuation 10000 Expiration Date 4/17/07 Qty Unit Charge Per Extension BASE FEE 45.00 8.00 9.0000 ------------------------------------------- THOU BLDG 2,001-25,000 --------------------------------- 72.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 106.95 Plan Check Fee 26.74 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 171.00 .4500 ---------------------- =------------------------------ EA ELEC DEVICE/FIXTURE >20 =---------------------- 76.95 Permit MECHANICAL Additional desc . Permit Fee . . . . 4.5.50 Plan Check Fee 11.38 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 4.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 26.00 Permit PLUMBING Additional desc . Permit Fee . . . . 18.00. Plan Check Fee 4.50 Issue Date Valuation . . . . 0 Expiration Date 4/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 1,694SF DWELLING, FIRE REPAIR TO MASTER LQPERMTT Application Number . . . .. . 06-00002712 ------------------------------------------=--------------------------7------ Special Notes and Comments BEDROOM/NEW ELECTRICAL WIRING THROUGHOUT RESIDENCE. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. October 19, 2006 9:44:36 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . .. ENERGY REVIEW FEE 7.61 STRONG MOTION (SMI) - RES 1.00 Fee summary Charged Paid --------------------- Credited ---------- Due --------------------------- Permit Fee Total 287.45 .00 .00 287.45 Plan Check Total 118.67 00 .00 118.67 Other Fee Total 8.61 .00 .00 8.61 Grand Total 414.73 .00 .00 414.73 LQPERMIT Bin # City of La QuintaA L■Ay/ • D Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico 9 ® Quinta, CA 92253 - (760) 777-7012 ee Building Permit Application and Tracking Sheet Permit .# ^Zi( Oho Project Address: Owner's Name: . A. P. Number: Address: ZO C Legal Description: Contractor: City, ST, Zip: CJ1A Telephone: 7&C, -i641 s = Address:1 Project Descit tion: l 70 Cel City, ST, Zip: r' i f 0 I'% oar ilo Telephone:ILI x` ` _., s G / r I/1/1 lX State Lic. # : City Lic. #: Arch., Engr., Designer: he Zf ! CC4 cejt re! n Address: City, ST, Zip: Telephone: r State Lic. #: r " ,' , , Name of Contact Person:tgarr -Jr Sq. Construction Type: yp . Occupancy: , Project type (circle one): New Add n Alter Repair Dem Ft.: # Stories: # Units: AV Telephone # of Contact Person: J14 6 Estimated Value of Project: v00 aWW APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FAES Plan Sets Plan Check submittedrz- 4 ItemStructural Calcs. Reviewed, ready for corrections Plan Check DepositTrussCalcs. CalledContact Person — 101 Plan Check Balance Energy Calcs. Plans picked up -211f196 Construction Flood plain plan Plans resubmitted S/pb Mechanical Grading, plan 2°d Review, ready for orrections/is ue 064 Electrical NtJ— Plumbing Subcontactor List Called Contact Person Grant Deed Plans picked up H.O.A. Approval: Plans resubmitted Grading IN HOUSE:- ''d Review, ready fo orrectio issue Developer ee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 6 School Fees Total Permi ees l e cf S j N Coi.. r• c a • - G IOI b • K (t, twl C 1 io December 20, 2007 Ms. Rosa Alvarez 80070 Barcelona Avenue Indio, CA 92201 Ot G . BUILDING & SAFETY DEPARTMENT. RE: Building Permit Extension Request — 53965 Avenida Madero. Dear Ms. Alvarez: To vNolee - cao moc p z F I have reviewed your letter dated December 14, 2007, requesting a time extension for the fire damage repairs being done at the above address under Building Permit #06-2712. Our records indicate the following status on this project. Inspection status: Permit issued.: 10/23/06 Last successful inspection:. 01/12/07 Roof Nail . 180 -day expiration date: 07/11/07 180 -day extension date: 01/07/08 Under the provisions of California Building Code Section 106.4.4, your. request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than once," please be advised that unless the project passes its next required inspection on :or before Monday, January 7, 2.008,, your building permit will expire automatically: Yours truly, Greg Butler Building & Safety Manager P.O. BOX 1504 • LA QUINTA, CALIFORNIA 92247-1504 78495 CALLS TAMPICO • LA QUINTA, CALIFORNIA 92253 (760) 777-7012 • FAX (760) 777-7011 CeLo IV\,. S11C <lC CA, COaU {?I'1 X1 i - 3i -7 60 Lt 9-,70 11 ". i rno concern C Lo n - o 5 e\ c1 r cc ,C, s - 9 ()S La, ' ; ,v . C) ir eve.► i a ` aa r a cAvvvol +- 4cvvfD * u-)' 4 CQ s A-) A MAkl !A ave A W S l I v L c bo OI -e t'v 11 -;rte ' l.S -j tie lask 1eFfi. c5 jC 11C V2 a, qoz-S` -cf)CoAl\, be. Voad-VEA al ^A -e' IUNIV% -4p 0 , ov 4* CITY OF LA QUINTA BUILDING & SAFEIY DEPT. APPROVED FOR CONSTRUCTION. TITLE 24 REPORT Title 24 Report for: Mr. Bogar Barrera 53-965 Avenida Madero La Quinta, CA 92253 Project Designer: Report Prepared By: slo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 Job Number: Ig092106 Date: 9/21/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: Ig092106 User Number: 5732 I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating and Cooling Loads Summary 11 EnergyPro 4.2 by EnergySoft Job Number: Ig092106 User Number: 5732 1 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _Mr_B -B.arlera [jd Single Family ❑ Addition Total Conditioned Floor Area: 9/21/20-0-6 Project Tie _53.=96.5A\cen.id.a_Madem--La-Quinta EJ E] ❑ Multi Family Date Project Address n/a ft2 Building Front Orientation: Building Permit # Santamp o Documen tion Author 0 ft2 (760) 485-8927 Telephone plan Check/Date FE1emavP_ro Compiffilce Method Slab on Grade Area: 1,825 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance ft _(kBtu/sf-yr) Design Design Margin 1.00 Space Heating 1.42 1.05 0.36 Number of Stories: Space Cooling 53.75 51.20 2.55 Fans 8.09 8.53 -0.44 Domestic Hot Water 12.12 10.77 1.35 Pumps 0.00 0.00 0.00 Totals 75.38 71.55 3.83 Percent better than Standard: 5.1% Building Type: [jd Single Family ❑ Addition Total Conditioned Floor Area: 1,825 ft2 EJ E] ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: New D9A3 Mole House Natural Gas Slab on Grade Area: 1,825 ft2 Fenestration: ❑ Average Ceiling Height: 9.5 ft Area: 238 ft2 Avg. U: 0.41 Number of Dwelling Units: 1.00 - - Ratio: 13.0% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area JAVACJSystem x_825 X7,338 x..0.0_ -Conditioned- -Setback- 2 .-n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Roos- Wood_ Roof - Wall_ Wood_ .DDIIr None Wall_ Wood - Wall Wood_ Wall_ Wood - Wall _ Wood_ Door None Wall_ Wood_ Wall_ Wood- Wall- Wood_ Wall_ Wood_ Wall_ Wood_ Wall_ Wood_ Wall_ Wood_ Wall_ Wood_ Wall_ Wood - Wall_ Wo.od- Wall- Wood_ Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments -832 -0_.029_ _R-18 0`0._0_ 0 1 _9.9.3_ _0_025.0.38 R-0.0 QHS IN IN EJ E] New_ D2 -A11 Whole -House New 01-A18 Wholeliouse __153_ -0102 013 COQ 9.0 _90 .8. 0-50.0_ done_ R-0-1-90_ 9.0 _____18__0_10Z R-13.0`00_ 9.0 22 _0_102 013_ _R-0-0 _90_ 90 54 _0102 013.0•`0-1-0_ 9.0 -3-4---0-07-4- 013 -45_ 90_-9.0 40 0_50.0 _None_ X0.0_ _90__9.0 95. 0.0.7_4.013_ _EZ -4..5_ _09.0 9.0. 0 074 013.0`-4_5_ _90_____q0 -381 nn74 0=13 R --4_5_x.8.0__9.0 74.0 n74 013 _R:4-5_ -270 _94 9.3_ 0_0.7_4 013 -R=4-5_80__90 124 0-07_4.013__R-4_5_-270 90 260_074.0,.3_ _R1.5_ 180 90 81 -0.0.79_ _R13_ x-45_-27090 26_ _0-179.013_ R-45 -0_-9.0 34 _0-)7-4 013 0R-4.5_ 97.090 358.0_074 -B13_ _R--4..5_ 0 go IN IN ®❑New IN IN IN IN IN X EX INElNew IN IX IN [X 1X a 1:1 ❑ ❑ ❑ El ❑New El ❑ ❑New El El ❑ ❑New ❑ El ❑❑ New 0-9- 3 Whole louse New 28-A4 Whole±iouse - 9_A3 Whole1touse New 9.9-A3 Whole -House New 09J_a3 Whole- ouse New_ D9- 3 Whole -House 28-A4 WholeJjouse New- -0.9--A3- WholeJ3ouse New -9--23 Whole -House 09J93 Whole_Ho.use 9R-+3 Whole±[ use New_ 09-93 Who.teJdous.e New 0.913 Whole -House New D9A3 Mole House M 3 Whole -House NewD9A3 WholeJjouse New_ D3A3 Whole13ouse New D91 3 Whole -House ❑ ❑ ❑ ❑ - - ❑ ❑ 55 EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Page:3 of 11 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Mr. Bogar Barrera 9/21/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ WJndow Front tE)- _25-a 0-MO-UFBC -0-3J NFRC _9.0_ -90- blebt_Milgard_ClassicloE1Z0_Clr_VlnyL- Wbole-House 2 Window Front (E_ 25.0 1.280 116-A 0_80 116-B 90 90 RemovedSingle Metal Clear Whole House 3 Window Left (S)_ 16.0 0.390 NFRC 0_31 NFRC 180 90 New Milgard Classic LoE170C1r Vinyl Whole House 4 Window Left (S) 20.0 0.390 NFRC 0_31 NFRC 180 90 New Milgard Classic LoE170C1r Vinyl Whole House 5 Window Left (S)_ 16.0 1.280 116-A 0_80 116-B 180 90 RemovedSingle Metal Clear Whole House 6 Window Left (S)_ 20.0 1.280 116-A 0_80 116-B 180 90 RemovedSingle Metal Clear Whole House 7 Window Rear (W) 40.0 0.390 NFRC 0.31 NFRC 270 90 New Milgard Classic LoE170C1r Vinyl Whole House 8 Window Rear (W) 40.0 1.280 116-A 0.80 116-6 270 90 RemovedSingle Metal Clear Whole House 5 Window Left (S)_ 40.0 0.390 NFRC 0.31 NFRC 180 90 New Milgard Classic LoE170C1r Vinyl Whole House 10- Window Rear (W) 30.0 0.390 NFRC 0_31 NFRC 270 90 New Milgard Classic LoE170C1r Vinyl Whole House " Window Left (S) 3.0 0.650 NFRC 0_48 NFRC 180 90 Existing WECK. GLASS BLOCK 8x8x4 Whole House 12 Window Right (N) 3.0 0.650 NFRC 0_48 NFRC 0 90 Existing WECK, GLASS BLOCK 8x8x4 Whole House 13 Window-Right_(N)_ 12-Q 0-65 -N.ERC QA8 -NERC 0_ 90 New WNECX, GLASS-BI9CJK8x8x4_ Whole -House 14 Window Right (N)_ 3.0 0.390 NFRC 0_31 NFRC 0 90 New Milgard Classic LoE170Clr Vinyl Whole House 15 Window Ri hg t (N 20.0 0.390 NFRC 0_31 NFRC 0 90 New Milgard Classic LoE170C1r Vinyl Whole House 16 Window Right (N) 6.0 0.390 NFRC 0_31 NFRC 0 90 New Milgard Classic LoE170C1r Vinyl Whole House 17 Window Right (N)_ 2000 0.390 NFRC 0_31 NFRt(- 0 90 New Milgard Classic LoE170C1r Vinyl Whole House 18 Window Right (N) 3.0 1.280 116-A 0_80 116 B 0 90 RemovedSingle Metal Clear Whole House 12 Window Right (N)_ 20.0 1.280 116-A 0.80 116_B 0 9Q RemovedSingle Metal Clear Whole Houma 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 Ti Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 1,273 3.50 28 0_98 0 26-A1 New Whole House /Slab on Grade Concrete, Heavyweight 552 3.50 28 0_98 2 26-A1 New Whole House / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 138 None No Insulation 26-A1 New Whole House Slab Perimeter 68 None No Insulation 26-A1 New Whole House Run Initiation Time: 09121106 05:02:35 Run Code: 1158840155 EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Page:4 of 11 t, Certificate Of Compliance : Residential . (Part 2 of 4) CF -1 R Mr. Bogar Barrera 9/21/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 20 -Mndow Right (.N)_ 6-0 L.280 116A_0..8.0 116_8. _0_ --q0 Rem.ov_edSin&—MetaLC1ear Mole House 21 Window Right (N 20.0 1.280 116-A 0_80 116-B 0 90 RemovedSingle Metal Clear Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 Ti Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Le Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 09/21/06 05:02:35 Run Code: 1158840155 EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Page:5 of 11 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Mr. Bogar Barrera 9/21/2006 Protect Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 94% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Rheem 41VRP50PT Small Gas No Pipe Insulation 1 40,000 50 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length Add 1/2" Control # HP Ty In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building eating require installer testing and certification and field verification by an approved HERS rater. Designer caner (p r Bus' ess & Professions Code) Documentation Author Name: _ Name: slo Title/Firm: Title/Firm: Santiago Lopez-Ocampo Address: Address: P.O. Box 1018 La Quinta, CA 92247 Telephone: Telephone: (760) 485-8927 Lic. # ____s'g ) 5 2. c v d 'S .2!•06 (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number._ Ig092106 Paae:6 of 11 1 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Mr. Bogar Barrera 9/21/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the o.. may.. y F... JYJlll l{.4 LIV 11 d11V Y VGU111tIn Wt1u1n bu Unnntteu. Plan Field [HIGH Design - Verify Thermal Mass: 1273 sgft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 552 sgft Covered Slab Floor, 3.50" thick at Whole House HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- in", -- .. .. V11 111C111VVJ At1U InUbI UB rep Urteu on the lir-4m installation certi icate. Plan Field The HVAC System "HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansio Valve. The Cooling System "Carrier 58MVB80-20 CNP 38HD 5 T" includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Paoe:7 of 11 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X El - apply to exterior mass walls). apply § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ 0 ❑ b. outside air intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include ❑ a ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ N ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ER ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Page:8 of 11 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ © ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ x❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section fl 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolslwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)B: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Page:9 of 11 Residential Kitchen Lighting Worksheet WS -5R Mr. Bogar Barrera 9/21/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Wafts High Efficacy Quantity Wafts Other Wafts (1) 2 ft U -Tube T8 Elec Yes X No 39.0 x 3 = 117 or (1 26w Compact Fluorescent Triple 4 Pin Yes X1 No 1 28.0 x 4 = 112 or Recessed Incandescent Yes I No X1 60.0 x 1 or 60 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 229 B: 60 COMPLIES IF A z B YES FXI NO ❑ EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: lg092106 Page: 10 of 11 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. Bogar Barrera 9/21/2006 SYSTEM NAME FLOOR AREA HVAC System 1,825 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 75,000 Total Output (Btuh) 75,000 Output (Btuh/sqft) 41.1 Cooling System Output per System 55,100 Total Output (Btuh) 55,100 Total Output (Tons) 4.6 Total Output (Btuhlsgft) 30.2 Total Output (sgft/Ton) 397.5 Air System CFM per System 1,750 Airflow (cfm) 1,750 Airflow (cfm/sgft) 0.96 Airflow (cfm/Ton) 381.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions :ATING SYSTEM PSYCHROME' 26.0 of 68.7 of Outside Air 0 cfm Supply Fan 1750 cfm 68.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 881 21,258 2,488 658 26,370 0 2,554 2,434 0 0 0 0 0 0 0 0 0 2,5541 2,434 26,36:7[:::j;8 31 238 Carrier 58MVB80-20 CNP 38HD 5 T 47,347 0 75,000 Total Adjusted System Output 47 347 0 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2m Jan 12 am RICS (Airstream Te 68.7 of . 109.0 of Heating Coil rstream T K Return Air Ducts `S 111.0/77.6OF 79.4/62.6OF 79.4/62.6OF . 53.9/52.6OF Outside Air O 0 cfm Supply Fan 1750 cfm 79.4/62.6 of Cooling Coil h Return Air Ducts `{ Supply Air Ducts 107.7 of ROOMS 70.0 of Supply Air Ducts 55.3 / 53.2 of 40.8% R.H. ROOMS 78.0 / 62.1 of EnergyPro 4.2 by EnergySoft User Number: 5732 Job Number: Ig092106 Paoe:11 of 11 1 C7 f.