PLBG (9902-063) + AR (10684)54125 Avenida Madero
9902-063
10684
LICENSED CONTRACTOR DECLARATION
hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
1 7461 9 042 /- MZ910G
DAte.,1 f!/r'Y ' r Signature of Contractor?,
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractcir's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their solo
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( .,) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals ?
Code). "
( ) 1 am exempt under Section B&P.C. for this reason
Date f Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
. ( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation' insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
G01MW L;AGILE IINS Y-100
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
C,otle, I shall forthwith comply with'those provisions': ,,,, ,,, / i
'Date: % -.. I /_ 7 ! Applicant - R, ---^ ! ,. ; v. ' .
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees. .
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject• to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. l,,agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon li
the ,above mentioned property for inspection purposes., -
VSignature (Owner/Agent) AL -- _v L Date.
BUILDING PERMIT PERMIIMU-063
DATE 2/12,14}') VALUATION $4,40ft.Qtj LOT TRACT
JOB SITE
ADDRESS;_!-, 64-125 a GVEN1.#.➢A]VIAWER0
APN 774-192-017
!
OWNER
CONTRACTOR/DESIGNER/ENGINEER
54 3 AVE].V;ti.)AAIADERO '
H4033 CABAlON RI). INDIO, C:.rt 92201
LA. QUM I:A i,'A '922$3
S's+aLM 1XISLR CA 92261
(76(J);346-2703 CK4. 342
USE OF PERMIT
SEPTIC AliAiNDON, SEW M, G't..►IVtWfC`t
VALUATION 1,400ALS
g-N.A1 ►a• i.,:,.PE ;JA 'l OA, ,,Tl".3 .R ) ION
N.; YYC.ViI
PERMIT VY i'tR%ity'GM.A R
P UMI3.ING ME -_ Sh WHR 101-000-419-000 Oil
SURIMM, C )I'1;MtJM(:)N AND PLAN f;t• RIN
$31100
LESS PRJ," -PAJID* FEES
$01110
BICE Tj
DATE
BY /
/
DATE FINALED
INSPECTOR
d
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
POOLS -SPAS
BLOCKWALL APPROVALS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection _
Encapsulation
Gas Piping
Gas Test
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COACHELLA VALLEY WATER DISTRICT
CASH RECEIPT DETAIL
Received From: r h M (2T
a
Date
Address: . I -L
c
CO — (0A
_ /e--- •
l A Cj of U
Account No. C iJ (^ % :> a ,
7 J C)o,L at(sr)t
Tract
Service Address U ' / ,
_
A VE N / l l!'T e, -Q
G.A. Code
❑ Meter(s)
y .
❑ Service(s)
❑ Backflow(s)
' ❑ House Lateral(s)
. ❑ Detector Check(s)
❑ Meter Surcharge
Sanitation Capacity Charge
r"' -
' :
❑ W.S.B.F.C.
❑ Temporary Construction Meter
❑ Turn on Charge
❑ Uncollected Account - Name
❑ Inspection Fee - Tract -
' Fee -
❑ Plan Check Fees Water I Sewer - -
Tract -
❑ Bond Payment - A.D. - Bond
Assmt.
L7 Customer Deposit
❑ Other
TOTAL
$
Remarks:
`] Copy to:
Cash
Check l/ ri7,.
Water Service
Money
Cashier
Order
„c f .CVWD
438(11/89)
E C O,NO SEWER SERVICES....
-;& P.O. BOX 192
PALM,DESERT, CA 92261
7,;SOC Ow C 00 ALDER,
x:..10941
(/BUJ S4brL/y3 kibU) JZ?5-//t)U
FAX (760) 347.4978,
•DATE OF ORDER
CUSTOMER'S ORDER NO.
PHONE
MECH
HELPER
STARTING DATE
BILL TO
ORDER TAKEN BY
ADDRESS
r `^
❑ DAY WORK
❑ CONTRACT
❑ EXTRA
CIS,
C
JOB NAME AND LOCATION
JOBPHONE
uta.nri ry yr wvnrt PAYMENT TERMS NET 10 DAYS FROM DATE OF SERVICE
1%96 PER MONTH GHARGE AFTER3A DAYS,
TOTAL MATERIALS
TOTAL LABOR
PLEASE PAY FROM THIS INVOICE--
TAX
DATE COMPLETE RUEW% MAILED.
4 /) / (21 Qi /J,L_ _ TOTAL AMOUNT $ /
❑ No one homeI➢ Total amount due ❑ Total billing to
Signature for above work: or be mailed after
completion
I hereby acknowledge the satisfactory completion of work
of the above described work.
Building
Arlrlracc 54--125 Madera
Owner
Candelario Felix, Jr.
Mailing
Address SsaMe
Tity/
P.O..O. BOX 1504
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
City Zip Ile,_
. 'La Quina 92253 564-'5070
Contractor
Owner /Builder
State Lic.I City
& Classif. Lic. #
Arch., Engr:,
Designer
Address Tel.
City( Zip ( State I
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
Permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than rive hundred dollars ($500).
6.1,1s, owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose or sale.)
❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed If the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for'which this permit is. issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
jLaws of California. f "
ate Owner ^""`"••+
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
1 certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
No. 10684
BUILDING: TYPE CONST. OCC: GRP.
A.P. Number
Legal Description
Project Description
Room Addition
Sq. Ft.
Size 149
No. No. Dw.
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑
-Demolition ❑
Estimated Valuation
71673.50
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
64. 35
Const.
99-00
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
164.15
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Pi% !L'ne
Side Street Setback fromrC ter L ne
Side Setback from Prop
Lin
FINAL DATE INS ECT
41S
Issuedl:
Validate
Validati
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
2ND FL. SQ. FT.
POR. SO. FT. ®
GAR. SO. FT. ®
CAR P. SQ. FT.
WALL SO. FT. ®
Sp FT ®
ESTIMATED CONSTRUCTION VALUATION $
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM r
BAR SINK
I ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN.
URINAL
WATER PIPING
NOTE: Not to be used as property tax valuation
SLAB GRADE
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
SEWER OR SEPTIC TANK
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
DUCT WORK
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SO. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER'OUTPUT, B.T.U.
SO. FT. RESID ® 1% c
SEWAGE DISPOSAL
BOND BEAM
SQ.FT.GAR ® 3/ic
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEEELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP.
FRAMING U "2_
FINAL INSP.
ROOFING
/01
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
ib
IZ - 1l:1 G%I L. I 10(, .
(Z- ICN, WtiLLeS,
1
' Peril d
EX► s- 1144 Sows xL.. ,P r -
TO !3_ 2EMWE_
N
^1 --% `'/ I'I ' I . ` , c.Lh.C:iC. ' of ! CZ+. • r•" ,...
E:
-
- I I fJStJ _ A. j to rJ
—
I"1 5T t EX ISr I N G GavEr2
,clsrlN I P'wPosE WA L L-`
Doo (2 -
Foy EXt°EN I IoN or'
EX i 45r I tJ G
E TIOIJ
I II
. ' T-1 i I 9X SIaEE I - ► AInJ'i
j, I, Iv M/ iI E CtSi I► Hojsr
fes' 1
1/2. Xlp`I A,).:I--lw IvffS ( 6c, 4,,C.
Del-t-
54
l-t- t A.c el J2
54- I x f M
gCA-5010
'll
Carole Christensen, Analyst
Title -24 Energy Calculations
ENERGY CALCULATIONS FOR:
Candelario Felix
54-125 Avenida Madera
La Quinta, CA 92253
PROJECT: Felix Addition, (149.5 sq.ft.)
Addition alone
54-125 Avenida Madera
La Quinta, CA 92253
Addition Design Proposed Design Compliance Margin
50.9.1 49.34 + 1.57
Addition: Walls R-19; Roof R-19, Duct R-4.2;
Dual Fenestration, Default U -value; Roller Shades
Existing water heater
.Existing HVAC with at least AFUE.78%, SEER 10.0
Table of Contents
CF -1R
MF -1R
C -2R
C -3R
HVAC Sizing
47-596Lake Canyon Drive, Aguanga, CA 92536 79-733 Country Club Drive, Bermuda Dunes, CA 92201
1-800-735-8152
Member CABEC
California Association of Building Energy Consultants
TABLE OF CONTENTS TOC
Project Title.......:.. Felix Addition Date........ 11/23/94
Pro'ect Add 54-125 A d
ressna a Md
........ vea era
La Quinta CA
Documentation Author... Carole Christensen
Company ................ Carole Christensen, EA
Telephone .............. 1-800-735-8152
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 15
Bui ing Permi
Plan Check Da e
Fie Check/ Da e
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -TOC
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
TABLE OF CONTENTS
Report
Page
FORM
CF -1R ................
1
FORM
MF -1R ................
3
FORM
C -2R .................
5
FORM
C -3R .................
8
HVAC
SIZING ...............
10
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... Felix Addition Date........ 11/23/94
Project Address 54-125 Avenida M d
•••••••• a era
La Quinta CA
Documentation Author... Carole Christensen
Company ................ Carole Christensen, EA
Telephone .............. 1-800-735-8152
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 15
Building Permi
Plan Check Da e
Fie d Check/ Date -
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type ...
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
149.5 sf
Single Family Detached
New
Front Facing 90 deg (E)
.11
1
Slab On Grade (Package D)
BUILDING SHELL INSULATION
Component
Insulation
Assembly
Type
R -value
U -Value
Wall
R-19
0.065
Roof
R-19
0.046
Door
R-0
0.330
S1abEdge
R-0
0.900
Orientation
Window Back (W)
Type
Location/Comments
left, back, right
Wood
to outside
FENESTRATION
# of Interior
Area U- Pan- Shading/
(sf) Value es Description
20.0 0.870 2 Roller.Wht
Exposed
S1abOnGrade Yes
S1abOnGrade No
THERMAL MASS
Over -
Exterior hang/ Framing
Shading Fins Type
None . Yes Metal
Area Thickness
(sf) (in) Location/Comments
134 3.5 Addition
16 3.5 Framing
HVAC SYSTEMS
Minimum Duct
Equipment Type Efficiency Location
Gas
AirCond
0.780 AFUE Attic
10.00 SEER Attic
Duct Thermostat
R -value Type
R -4.2 Setback
R-4.2 Setback
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
SPECIAL FEATURES/REMARKS
This is a 149.5 sq.ft. addition to a 1270 sq.ft. residence.
Existing water heater and HVAC equipment
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name....
Candelario Felix
Name....
Carole Christensen
Company.
Company.
Carole Christensen, EA
Address.
Address.
47-596 Lake Canyon Dr.
Aguanga, CA 92536
Phone...
(619) 564-5070
Phone...
1-800-735-8152
License.
Signed..
Signed..
a e
a e
ENFORCEMENT AGENCY
//-'73-51f
Name....
Title...
Agency..
Phone...
Signed..
(date)
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R
Project Title.......... Felix Addition Date........ 11/23/94
Project Address........ 54-125 Avenida Madera
La Quinta CA
Documentation Author... Carole Christensen
Company ................ Carole Christensen, EA
Telephone .............. 1-800-735-8152
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 15
Field Check Date
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM MF -1R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturers labeled R -Value.
*150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
*150(d): Minimum R-13 raised floor insulation in framed floors;
minimum R-8 in concrete raised floors.
150(i): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets CEC quality
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
exfiltration controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label with
certified U -value, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets CEC quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and gas logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R
Project Title.......... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM MF-iR
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
Design- Enforce-
er ment
110-13: HVAC equipment, water heaters, showerheads and faucets
certified by the CEC.
150(i): Setback thermostat on all applicable heating systems.
150(j): Pipe and Tank insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or
backup solar hot water tanks) have insulation blanket (R-12
or greater) or combined interior/exterior insulation (R-16
or greater).
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating
sections of hot water system.
4. Cooling system piping below 55 degrees insulated.
5. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC
sections 1002 and 1004; ducts insulated to a minimum
installed value of R-4.2 or ducts enclosed entirely within
conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System installed with:
a. At least 36 inches pipe between filter and heater for
future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnace, pool heater, spa heater or
household cooking appliance have no continuously burning
pilot light (Exception: Non -electrical cooking appliance
with pilot < 150 Btu/hr.).
LIGHTING MEASURES
Design- Enforce-
er ment
150(k)• 40 lumens/watt or greater for general lighting in
kitchens and rooms with water closets; and recessed ceiling
fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY Page 5 C -2R
Project Title.......... Felix Addition Date........ 11/23/94
Project Address........ 54-125 Avenida Madera
La Quinta CA
Documentation Author.:. Carole Christensen
Company ................ Carole Christensen, EA
Telephone .............. 1-800-735-8152
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 15
Field Check Date
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
MICROPAS4 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
6.13
7.62
-1.49
Space Cooling..........
44.78
41.72
3.06
Total
50.91
49.34
1.57
*** Water Heating not calculated ***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type ..
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .............
Ground Floor Area..........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.....
149.5 sf
Single Family Detached
New
Front Facing 90 deg (E)
.11
1
ReducedYear
Slab On Grade
1
1196 cf
149.5 sf
149.5 sf
149.5 sf
13.4 % of FA
8 ft
(Package D)
COMPUTER METHOD SUMMARY Page 6 C -2R
Project Title.......... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
Zone Type
ADDITION
Residence
Surface
ADDITION
1 Wall
2 Wall
3 Wall
4 Roof
5 Door
Surface
BUILDING ZONE INFORMATION
Floor
Area Volume
(sf) (cf)
# of
Dwell Cond- Thermostat
Units itioned Tvne
150 1196 0.11 Yes Setback
OPAQUE SURFACES
Area U- Insul Act Solar Form 3
(sf) value R-val Azm Tilt Gains Reference
Vent Special
Height Vent Area
(ft) (sf)
2.0 n/a
Location/
Comments.
92 0.065 R-19 180 90 No W.19.2X6.16 left
84 0.065 R-19 270 90 Yes W.19.2X6.16 back
36 0.065 R-19 0 90 No W:19.2X6.16 right
150 0.046 R-19 0 0 Yes R.19.2X6.24
20 0.330 R-0 0 90 No None Wood
PERIMETER LOSSES
Length F2 Insul Solar
(ft) Factor R-val Gains Location/Comments
ADDITION
6 S1abEdge 32
# of
Area Pan- Frame
Surface (sf) es Type
ADDITION
1 Window
Surface
0.900 R-0 No to outside
FENESTRATION SURFACES
Vent
SC
SC
Interior
Open
U- Act Glass
Int
Shading/
Type
value Azm Tlt Only
Shade
Description
20.0 2 Metal Slider 0.870 270 90 0.88 0.40 Roller.Wht
OVERHANGS AND SIDE FINS
Window— Overhang Left Fin Right Fin—
Area Left Rght
(sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
ADDITION
1 Window 20.0 4.0 n/a 2.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a
COMPUTER METHOD SUMMARY Page 7 C -2R
Project Title.......... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM C -2R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
-Mass Type
ADDITION
1 S1abOnGrade
2 S1abOnGrade
THERMAL MASS
Area Thick Heat Conduct- Surface
(sf) (in) Cap ivity R -value Location/Comments
134 3.5 28.0 0.98 R-0.0 Addition
16 3.5 28.0 0.98 R-2.0 Framing
HVAC SYSTEMS
Minimum Duct Duct Duct
System Type Efficiency Location R -value Efficiency
ADDITION
Gas 0.780 AFUE Attic R-4.2 0.830
AirCond 10.00 SEER Attic R-4.2 0.810
SPECIAL FEATURES/REMARKS
This is a 149.5 sq.ft. addition to a 1270 sq.ft. residence.
Existing water heater and HVAC equipment
CONSTRUCTION ASSEMBLY Page 8 3R
Project Title.......... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
Reference Name . W.19.2X6.16
Description .... Wall R-19 2x6 16oc
Type ........... Wall
R -Value ........ 19 sf-F/Btuh
Framing
Material ..... FIR.2X6
Spacing ...... 16 inches on center
Fraction ..... 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
.Name Description
O. FILM. EX
1. STUCCO.0.88
2. BLDG.PAPER
3c. BATT.R19
3f. FIR.2X6
4. GYP.0.63
I. FILM.IN.WLL
Exterior air film: winter value
0.875 in stucco
Building paper (felt)
R-19 batt insul (cavity = 5.5 in)
2x6 in fir framing
0.625 in gypsum or plaster board
Inside air film: heat sideways
FRAMING ADJUSTMENT CALCULATION
Cavity
Total Unadjusted R -Values
Framing
Cavity Frame
R -Value R -Value
0.17
0.17
0.17
0.17
0.06
0.06
17.80
--
--
5.45
0.62
0.62
0.68
0.68
19.51 7.15
Total
U -Value: (1 / 19.51 x 0.85) + (1 /
7.15
x 0.15) =
0.065
Btuh/sf-F
Total R -Value:
1 /
0.065 =
15.49
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 9 3R
Project Title.. ....... Felix Addition Date........ 11/23/94
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -FORM 3R
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
Reference Name . R.19.2X6.24
Description .... Roof R-19 2x6 24oc
Type ........... Roof .
R -Value ........ 19 sf-F/Btuh
Framing
Material ..... FIR.2X6
Spacing ...... 24 inches on center
Fraction ..... 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Name Description
0. FILM.EX Exterior air film: winter value
1. SHNGL.CEMENT Asphault-cement shingles
2. BLDG.PAPER Building paper (felt)
3. PLY.0.50 0.50 in plywood
4. AIR.RF.3.50 3.5 in & greater air space: heat flow up
5. BATT.RI9.0 R-19 batt insul (cavity > 5.5 in)
7. GYP.0.50 0.50 in gypsum or plaster board
I. FILM.IN.RF Inside air film: heat flow straight up
FRAMING ADJUSTMENT CALCULATION
Cavity
Total Unadjusted R -Values
Framing
Cavity
R -Value
Frame
R -Value
0.17
0.17
0.21
0.21
0.06
0.06
0.62
0.62
0.80
0.80
19.00
19.00
0.45
0.45
0.61
0.61
21.92 21.92
Total
U -Value: (1 /
21.92 x 0.93) + (1 / 21.92
x 0.07) =
0.046
Btuh/sf-F
Total R -Value:
1 /
0.046 =
21.92
sf-F/Btuh
HVAC SIZING Page 10 HVAC
Project Title.......... Felix Addition Date........ 11/23/94
Project Address........ 54-125 Avenida Madera
La Quinta CA
Documentation Author... Carole Christensen Bui ing Permit
Company ................ Carole Christensen, EA
Telephone .............. 1-800-735-8152 Plan Check Da e
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 15
Field Chec Date
MICROPAS4 v4.02 File-FELIXADD Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1017 User -Carole Christensen, EA Run-DS.72AC10.OR19.19.4
GENERAL INFORMATION
Floor Area ................. 149.5 sf
Volume.. ............ 1196 cf
Front Orientation.......... Front Facing
Sizing Location............ INDIO
Latitude... .... ....... 33.7 degrees
Winter Outside Design...... 29 F
Winter Inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range........ ..... 30 F
Interior Shading Used...... Yes
Exterior Shading Used...... Yes
Overhang Shading Used...... Yes
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Description
Heating
(Btuh)
90 deg (E)
Cooling
(Btuh)
Opaque Conduction and Solar...... 2274 895
Glazing Conduction ............... 713 592
Glazing Solar .................... n/a 434
Infiltration ..................... 705 418
Internal Gain .................... n/a 281
Ducts ............................ 369 262
Sensible Load .................... 4062 2881
Latent Load ...................... n/a 576
Minimum Total Load 4062 3458
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
78-495 CALLE TAMPICO — LA QUINTA, CALIFORNIA 92253 – (760) 777-7000
FAX (760) 777-7101
TDD (760) 777-1227
December 19, 1997
Candelario Felix, Jr.
54-125 Avenida Madero
La Quinta, CA., 92253
RE: Room Addition Permit #10684
Dear Mr. Felix
The purpose of this letter is to inform you that your Room Addition Permit #10684, for the
project at 54-125 Avenida Madero, has expired. In accordance with 1994 UBC section' 106.4.4,
no further work may be performed until a new permit has been issued.
Please contact Daniel P. Crawford Jr., Building Inspector I, at (760) 777-7012 to obtain any
information you need regarding a new permit and/or any required inspections. Should you
choose not to complete the project, we would then have to pursue any or all of the following
actions:
1) Abatement of the project through the City Attorney's' Office and Code Compliance Division.
2) Notice of non -conforming structure placed upon property profile.
3) Action filed with Contractor State License Board. Optional if Owner/Builder.
Please contact us at your earliest convenience prior to 10 working days to resolve this'issue, and
for any questions you may have.
Sincerely,
Mark Harold
Buildin & Safety Manager
Daniel P. Crawford J .
Building Inspector I
cc: file
dpc
MAILING ADDRESS - P.O. BOX 1564 - LA QUINTA, CALIFORNIA 92253 ''J