BLCK (13-1002)54575 Avenida Madero
13-1002
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
13-00001002
Property Address:
•54575 AVENIDA MADERO
APN:
774-261-004- -
Application description:
WALL/FENCE
Property Zoning:
COVE RESIDENTIAL
Application valuation:
7000
Appliiccaanntt: Architect or Engineer:
-----------------
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 845115
Date: Contractor: /
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 ) I am exempt under Sec^ , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/09/13
Owner:
DUCHENE FAMILY TRUST
P.O. BOX 10389
PALM DESERT, CA 92 D
(760)272-4691
O ASG 1 p13
Contractor:
HEY DUDE CONSTR N
PO BOX 1018
THOUSAND PALMS, 92276F NPN
(760)343-5272
Lic. No.: 845115
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy'number are:
Carrier STATE FUND Policy Number 90508057
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
0 of the Labor Code, I sha thwith comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE W ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRI AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN AD ION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shalt defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building c truction, and hereby authorize representatives
enter of this countyto upon the above-mentioned property f 'nspection purpo
Date: Signature (Applicant or Agent)'
Application Number . . . . . 13-00001002
Permit . . .
WALL/FENCE PERMIT 2013
Additional desc . .
Permit Fee . . . .
75.79 Plan Check Fee
.00
Issue Date . . . .
Valuation . . .
. 7000
Expiration Date . .
2/05/14
Qty Unit Charge
Per
Extension
1.00 47.1900
LS MISC WALL, FIRST 100 LF
47.19
2.00 14.3000
EA MISC WALL, ADDL 50 LF
28.60
----------------------------------------------------------------------------
Special Notes and Comments
INSTALL 144 L.F. OF 6
FT. HIGH GARDEN
WALL AND 38 L.F. OF 4
FT. 6 INCH HIGH
GARDEN WALL ON 54515
PROPERTY SIDE (NOT
ON PROPERTY LINE). 2010
CALIFORNIA
BUILDING CODES.
----------------------------------------------------------------------------
Other Fees . . . . .
. . . . BLDG STDS ADMIN •(SB1473)
1.00
PLAN CHECK, WALLS
60.06
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
75.79 .00 .00
75.79
Plan Check Total
.00 .00 .00
.00
Other Fee Total
61.06 .00 .00
61.06
Grand Total
136.85 .00 .00
136.85
LQPERMIT
Bin #
City of La Quinta
Building &r Safety Division M
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
/ vC.v t FJ a4
Project Address: s- A--A —no
Owner's Name:
A. P. Number: -77z-1-Z,(41-00!ZAddress:
' 6 d h 6 j cj
Legal Description: CSN ,q
Contractor: v
City, ST, Zip: • wc E S t"frl
Telephone 7(0
Address:t Q g %
Project Description:
City, ST, Zip: z7
Telephon . 1
60 3si3-S 7 Z
:ifi•iii iii ii: i:;iiii+J ii ti ii:f:i!L:ii:i:
<i:<;::<>:::>,<<i;:i>:;:::<:>.:x:is:::.
« :::::;<i:>::::>::;:r::ii:::i:::<>;::<:::;>:<>:<;:
393G 6 o•A2/Jc t/ Cc%
State Lic. # : g // City Lie. #:
Arch., Engr., Designer:
Address:
City, ST, Zip:
e ep one:
a i
State . #• Lie.
Name of Contact Person:
Construction Type: Occupancy:
Pro ' ect type (circle cle one): New Add'
J e n Alter Repair Demo
Sq. Ft.: # Stories: # Units:
Telephone # of Contact Person:
Estimated Value of Project: 7,9Ct 9 - '—
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
ORCO STANDARD 6' TO 8' CMU SITE WALLS
OPTIONAL FLAT CAP DESIGN OUTER14: PER THE 2010 CBC
1. ALLOWABLE SOIL BEARING PRESSLNRE = 1500 PSF
2. ALLOWABLE LATERAL PASSIVE PRESSURE - ISO PCF
3. GROUT STRENGTH - 2000 PSI @ 18 DAYS.
4. REINFORCING STEEL : GRADE 60.
S. 1500 PSI MASONRY COMPRESSION STRENGTH.
'W CONT FOOTING ool
SEE QM FOR REQUIRED REQAR
AND FOOTING DIMENSIONS.
11. MAXIMUM CONTROL JOINT SPAaNG: 4o' t yG 2o' ox FOR
WALLS TO BE MORTAR WASTLED OR STUCCO COATED.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR O STRUCTION
DATE �' %
CIN OF LA QUINTA
"'I�
f ES
~ C31025 �N A
* ExP• 12-31-2012 *
sol C I V 1� ��v
F OF Ct+I�F�
6816, 6616, OR 6618 CMU
Ell
GROUTED ONLY 0 VERT
STEEL
NOTES:
.
1. CONCRETE BLOCK SHALL CONFORM TO ASTM C 90.
2. CONCRETE FOR FOOTING SHALL BE I PART CEMENT TO 2.1/2
El
Y' DROP -IN BAR
PARTY SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2
WGALLONS
OF WATER PER SACC PORTLAND CEMENT SHALL CONFORM
TO ASTM C ISO TYPE RIV. Ft - 2500 PSI
t6 STV JOINT
3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO
REINFORCEMENT @ 14' 0/C
ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP.
Z
(3 PLACES - 4 PLACES FOR T
& r WALLS). GCSE 05 STD.
4. REBAR SHALL BE CENTERED IN THE CONURETE BLOCK CELL IN
FOR SLUMP BLOCK
WHICH IT IS LOCATED.
W
5... CONCRETE BLOCK SHALL BE LAYED IN A RUNNING BOND
ly
`n
PROVI4 D 6
PATTERN WITH VERTICIL O7NTINLII7Y OF THE CELLS UNO.
1NOINATEH
SIDE OF CONTROL JOINTS,
6. ALL BLOCK CFr i c CONTAINING VERTICAL REW SHALL BE SOLID
:
&CS OF WALLS AND 0 WALL
GROUTED.
QWGNT
CHAAGES
Z USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART
p
CEMENT TO 1/2 PART LIME TO 4-1/2 PMTS DMP, LOOSE SAND.
4
8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PMT
b
CEMENT TO 3 PARTS SAND (GROUT MM Y CONTAIN 1 PMTS
PEA GRA VEL IF WEATHER COMM IONS ARE FAVORABLE AND BLOCK
T DOWEL CENTER OF
UNOBSTRUCTED CELL SIZE IS SUFRCISU TD ALLOW GOOD GROUT
CMU.
FLOW), WATER SHALL BEADOED TO PRODUCE GOOD GROUT FLOW
WITHOUT SEGIEGA TION OF THE G0AWTUEV75
9. BLOCK STEM MAY BE WET -SET I -1/2' 1NTO THE FOOTING "aLE
THE CO4CRE7E IS PLASTIC BLCCX STEM MAY BE PLACED TO
I
L EM GRADE 80TH SIDES
E77HAR EDGE OIF THE TRENCH TYPE FOOTING.
10. FOOTING ML67 BE POURED ON OR INTO UNDISTLRBED .
—_
_—
NATURAL SOIL OR ON COMPACTED FILL WITH MINIMUM
—
COWACTION OF !W %.
04 HOIRZ CONT.
ll. FIRST INSPEMON TO BE AFTER FOOTING TREIN04ES ARE
READY FOR 000XXETE AND ALL REQUIRED STEEL IS 77LD IN PLACE
SEMW INS PEC77ON TO SE WHM THE REQUIRED VERTICAL IS IN
PLACE AND THE BLOCK WALL IS READY TO GROUT
'W CONT FOOTING ool
SEE QM FOR REQUIRED REQAR
AND FOOTING DIMENSIONS.
11. MAXIMUM CONTROL JOINT SPAaNG: 4o' t yG 2o' ox FOR
WALLS TO BE MORTAR WASTLED OR STUCCO COATED.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR O STRUCTION
DATE �' %
CIN OF LA QUINTA
"'I�
f ES
~ C31025 �N A
* ExP• 12-31-2012 *
sol C I V 1� ��v
F OF Ct+I�F�
CHART FOR 6' TO 8' SITE WALL W/ SPREAD FOOTING
WIND
MAX.
1W,
DESIGN
WALL
SPREAD
'X' DOWEL
'Y' BAR
SPEEDHEIGHT
FOOTING
WIDTH
#4 C 40" O/c
#4 @ 40" 0/C
U V
6'-0"
I'-9'
33"
se ore - le cnu
36• oLc - le, cnu
w
-
8" - 8"
CL
w
#4 @ 40" 0/C 33"
#4 @ 40" 0/C
p p
6'-8"
1'-10"
36.0/C - 16• cmu
Sa• oic - 1e• cnu
Z W
9" -- 9'
W
n.
#4 C 32" 0/C 33"
1
7'-4' .
2'-0'
rT o/c - 16'CMU
27• 01C - Ie• cnu
10" 10'
CD U
#4 @ 24"0/C=— 33
#4 0 24" 0/C
2'-3'
I6. 0!C - 16• CMU
36' O/C - le' CMU
10' 10
ESARO
RETURN WAL1S IMiHlE
ARATIWGESWALE QCLIRE3. A 1/2 L#LOCIf
l NYLB°T OVT O SIWILF CIPADE PR017DE
/10011'Ei AND, NDRQ•-M BW QV FAC]i
SM Of TW IR 9L= LMATN - AS
ShO"w
t•n.a lever .
KNSME QF sm ■wa w a•o.wc
N ORQ0.1N MR 0M MA"
..NM M OWE • nV AS I!p/MD-
Cmomu'1•t wND wiwnuvr
6ROfmm
i
r. R)OTMG • • . • • •
r •• icxz mgr. ••a w • •oAbr x
XL w,ww wruvraaK nw
a
rrow ia•r
AU r'd'
FOOTING STEP DETAIL
RaQfE H
d
u m
ui
K F— N n
CITY OF LA QUINTA
031925
* Exp. 12-31-2012
SQIF OF C I F v
(IIIIIIIIIIIIIIIIIIIII
_@_COPYRIGHT OR COPYRIGHT PENDING. REVISIONS BY
THESE DESIGNS ARE THE PROPERTY OF
LENCH DESIGN STUDIOS, INC. UNAUTHORIZED USE, IN ANY
FORM, IS EXPRESSLY PROHIBITED AND EXTENDS TO ORIGINAL
AND MODIFIED DERIVATIVE PLANS AND IS APPLICABLE TO
INTENTIONAL AND UNINTENTIONAL INFRINGEMENTS.
(3) 15 GAL. CALIFORNIA FAN PALM
(WASHINGTONIA FILIFERA)
OR EQUAL (MIN. 1%" CALIPER @ TRUNK)
3/8" ROCK PALM SPRINGS
GOLD GROUND COVERED •' '
J
.00
Pv'
VERIFY CURB LOCATION
WITH CITY OF LA QUINTA
PUBLIC WORKS GCS
\N 53y S Oo 7o
ERS
STAIRS
TO DECK r
H.P. 7- I r.
. os
Ua
A.
o ..
in
COVERED PATIO Z
7-7
aatt J W • 0 "
GENERAL NOTES a a a
COVERED PATIO DECK
/ 1. FLOORS AT THE REQUIRED EGRESS DOORS SHALL
o NOT BE MORE THAN '/2' LOVER THAN TOP OF
THE THRESHOLD
2. EXTERIOR LANDING SHALL BE PERMITTED TO
HAVE A SLOPE NOT TO EXCEED'/4 UNIT VERTICAL IN
e z--------, __= 6-10"
W - I ------ HORIZONTAL.
- I
SET BAc 12 UNITS
3. THE DEVELOPER / CONTRACTOR / OWNER IS
cn 0 0 % irk
ADJONING LOT BELOW RESPONSIBLE FOR THE VERIFICATION OF EXISTING
F.F.:1 -2 ABOVE THE CURB I®I
SUBJECT PROPERTYCURB LOCATION (OR EDGE OF STREET PAVING IF
PAD: 0'-6" ABOVE CURB MEASURED @
ii ilii NO CURB EXISTINGS) FROM PROPERTY LINE(S)
CENTER OF LOT @ AVENIDA MADERO , I --- - WITH THE PUBLIC WORKS DEPARTMENT.
4. CONCRETE PAD SUPPORTING MECHANICAL EQUIPMENT
'S` 1 17-71 i, ii SHALL EXTEND NOT LESS THAN 3" -ABOVE GRADE. N
SET BACK s o I L ------- '-------- -
w° I ------------------ 0 5. ALL HVAC EQUIPMENT SHALL BE APPROVED PRIOR TO
-- W INSTALLATION BY NATIONALLY RECOGNIZED STANDARDS x
z AND EVIDENCED BY THE LISTING AND , LABEL ,OF AN
-;l L_GAPPROVED AGENCY.
b
I d
0
cLL-
j DATUM POINT j
IL—L--- ---v ----------_ d c
f
ADJONING LOT ±6' ABOVE
SUBJECT PROPERTY
f ,
II -
I r
II * •
L-------- ---
Is#x--
J I II Z
- ----- Ilse
W le.o sasr. e°\— _j
U o z W _'
O a
w m IL
Lu n 09
00 (nLL
a) LL
3'x3' CONC.
PAD
GARAGE
5
SLO LOP
4:1 4:1
BEDROO #2
ww
CN" R D SQUARE FOOTAGE: eV
ENTRY N
aN
o€ HOUSE: 1,972.00 SQ.FT.'
d GARAGE: 497.00 SQ.FT.
TOTAL 69
2,4 .00 SQ.FT. A 14
d °
TRASH CAN '
STORAGE ^
SIDEWA K, 8
z LOT= 4,976 SQ.FT.
I SEE MINOR SETBACKU e A
NEW BLOCK WALL REQUIRES
om 0 SEPARATE PERMIT& INSPECTIONADJUSTMENT APPROVAL bo 2 ; FROM CITY OF LA QUINTA LOT COVERAGE
I lO OO r N °Qz ".e BUILDING DEPARTMENT /HOUSE—GARAGE= 49.6%
PLANTINGS TO SCREEN w
I d ¢ PROPANE TANK
PROPERTY LINE 50:0'I CONCRETE °DRIVE
a AY '
T
a. • d a a
3/8" ROCK PALM SPRINGS O m V1
GOLD GROUND COVERED ~ N 4'-6" HIGH
¢ d 16 0" "BLOCK WALL
"a 3/8" ROCK PALM SPRINGSco s
Zi
Of O m da GOLD GROUND COVERED
`+ U a ga • g g
U ¢ (3) 15 GALu_ 4. CALIFORNIA FAN PALM GI i TA
CITY ROW W.
° ° d WATER (WASHINGTONIA FILIFERA) f3UILDI`!G SAFETY DEPT
9 ? d . a `. SERVICE OR EQUAL (MIN. 1Ya" CALIPER @TRUNK) DRAWN
d ,.
,a.
APPROVED
FOR/CgNSTRUCTION A. RADONI
CHECKED
aY S.L.
DATUM POINT DAT DATE
AVE. MADERO MID -POINT OF LOT 10-25-2012
DRIVEWAY APPROACH REQUIRES A
SEPARATE PERMIT AND INSPECTION SCALE
FROM CITY OF LA QUINTA PUBLIC 1 /H"=1' -O"
WORKS DEPARTMENT
JOB NO.
2012-019
SHEET
PLANS PREPARED BY:
LENCH DESIGN C S-1
SITE PLAN
STUDIO, INC. v
SCALE:1 /8"=1'-0"
A.P. LENCH II
PRESIDENT