Loading...
SFD (07-0005)54885 Avenida Madero 07-0005 P.O. BOX 1504 VOICE (760) 777-7012 1495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA; CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT -- -- Date: 3/16/07 Property Address: 54885 AVENIDA Owner: Application Number: 07-0000.0005 MADERO M/M WEISS APN: 774-264-020-20 -000000 PO BOX 450 Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 D Property Zoning: COVE RESIDENTIAL• Application valuation: 123272 MAR 16 2007 Contractor: Applicant: Architect or Engineer: LEGACY HOMES CALIFORNIA CITY OF 54425 AVENIDA MARTINEZ LA QUINTA LA QUINTA, CA 92253 FINANCE DEPT. n l/ (760)777-8317 Lica No.: 850833 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with . Section 7000) of Division 3 of. the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 850833 ';Date / Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of peri ry that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Bu ness and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolis or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. An violation of Section 7031.5 b P 9 P Y Y any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: - - 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the. structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or'herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ I I, as owner of the property, am exclusively contracting with licenses contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 'pursuant to the Contractors' State License Law.). 1 _ I I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of .perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EX MPT Policy Number EXEMPT certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the LabfRKERS' forthwith comply with. those provisions. i Date>. Applicant: \WARNING: FAIL RE TO SECUROMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT ANEMPLOYER TO CTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDOST OF COMPENSATION, DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR ST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this country -to enter upon the above-mentioned property for i paction purposes. Date: 3 'Iignature (Applicant or Agent): ' i Application Number . . . . 07-00000005 ------Structure. Information 1857 SFD ---=- " Other struct info . . CODE EDITION 01BMP04E05EN # BEDROOMS 2.00_ FIRE SPRINKLERS NO GARAGE SQ FTG 469.00' • PATIO SQ FTG 591.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 1857.00 Permit BUILDING PERMIT Additional desc.. _ Permit Fee . . . . 723.50 Plan Check Fee _ 470.28 Issue Date Valuation 123272 Expiration Date 9/12/07 Qty Unit Charge Per Extension BASE FEE 639.50 24.00 3.5000.THOU BLDG 100,001-500,000 84.00 Permit ELEC-NEW RESIDENTIAL = Additional desc . • Permit Fee . . . 95.09 Plan Check Fee 23.77 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/12/07 Qty Unit:Charge Per Extension BASE FEE 15.00 1857.00• .0300 ELEC NEW RES- MULTI FAMILY 55.71_ 469.00 0200 ELEC GARAGE OR NON-RESIDENTIAL 9.38 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 9/12/07 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Pee 59.00 Plan Check Fee 14.75 LQPERMIT . Application Number . . . 07-00000005 . Permit . . . . . . MECHANICAL Issue Date . . . . Valuation 0 Expiration Date 9/12/07 Qty Unit Charge Per Extension " BASE FEE 15.00 1.00 "' 9.0000 EA MECH FURNACE <=100K 9.00 1.00•" 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 6.5000 EA MECH -EXHAUST HOOD 6.50 Permit PLUMBING Additional desc Permit Fee 114.00 Plan Check Fee 28.50 Issue Date . . . . Valuation 0 Expiration Date 9/12/07- /12/07Qty QtyUnit Charge Per Extension BASE FEE •15.00. 10.00• 6.0000 EA PLB FIXTURE 60.•00 1.00 .15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB' WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN. SPRINKLER SYSTEM 9.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 2'.00 .7500 EA PLB GAS PIPE >=5 1.50 Special Notes and Comments 1857 SF SFD, 342 SF ROOF TOP DECK, R-3 OCC. TYPE V -N. CONSTR. 2001 CBC,CMC,CPC, 2004 CEC,. 2005 ENERGY CODES.**PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, WATER FEATURES and BBQ'S** ---------------------------------------------------------------------------- Other Fees . . . . . . . .. DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 47.03 DIF FIRE PROTECTION -RES. 140.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC.--RES 892.00 STRONG MOTION (SMI) - RES 12.32 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due ' LQPERMIT _ .. Application Number . . . 07-00000005 --------------------------- Permit Fee Total' 1006.59 -------------------- .00 .00 ---------- 1006.59 Plan Check Total 537.30 250.00 .00 287..30 Other Fee Total 4534.35 .00 .00 4534.35 . Grand Total 6078.24 250.00 00 5828.24 i ' ` • 44 CERTIFICATE OF COMPLIANCE R!N Desert Sands Unified School Districto 47950 Dune Palms Road ¢ BERMUDA DUNES O _ Cn RANCHO MIRAGE C7 Date ° 3/15/07 La Quinta, CA 92253 INDIAN WELLS No. 29287 (760) 771-8515 d. PALM LA QUINTA y 'QINDIO 1, Owner Legacy Homes APN # 774-264-020 Address 54425 Avenida MArtinez Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 54885 Avenida Madero 1857 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 *' Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living; sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 )01',857 S.F. or $4,883.91 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Legacy Homes California LLC Check No. ' 82861 Name on the check Telephone 760 8801-3445 Funding Residential By Dr. Doris Wilson Superintendent . Fee collected (exempted ;qtr fines KOzero Payment Recd $0.00 $4,883.91 Over/Under Signature - NOTICE: Pursuant to ovemment.Code' Section 670(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting ti • 03/0-1/2007417:39 FAX 760 674 9406 03/01/2001 17:22 FAX 98250537 6 60RDING REQUESTED BY: Fidelity National Title Company Escrow No. 11420 -KC Tine Order No. 607054314403 When Recorded Mail Document and Tax Statement To: Mr. and Mrs, Joel T. Weiss 103 Torena Way Oxnard, CA 93030 J F N T 001/001 16001/0,01 C 0 PY of Document Recorded on as has not been compared with Original. FRANK K. JOHNSON County Recorder RIVERSIDE C011NJY° CALIFORNIA Ariv: / /4 -4V4 -VCU vw-V r D GRANT DEED --- The undersigned grantor(s) declere(s) Documentary transfer tax is:(PURSUANT TO SECTION 11932 OF THE CALIFORNIA REVENUE AND TAXATION CODE) I X ) computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale, ( ) Unincorporated Area City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged. William R. Riley, Trustee of the Riley 1994 Trust hereby GRANT(S) to patrie:La R. Weiss, a married woman as her sole and seperate property the following described real property In the City of La Quinta County of Riverside, State of California: LO'r 20, BLOCK 274, UNIT NO. 25,SANTA CARMELIAT AT VALE LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 19, PAGE 50-51 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. DATED: January 18, 2007 State of William R. Riley, Trustee of the Riley 1994 Trust County of 1p On 60 before me, William R. Riley, Trustee notary public, . / (here insert name and title of the officer) personally appeared William R. Riley personally known to me (or proved tome on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESSy hand and offi ial seal. H001EP Nafty Pthlc Signature (Seal) SAaleorCdorodo MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7196) GRANT DEED (grant, wpd) (0 1 -06) CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 uiGcnr :>neet approvals are forwarded to the Building & Safety Department directly by Public Works. Please [)O NOT submit the Green Sheet (Public Works Clearance)'Packet to the Public Works Department until A d.L requirements listed below are. complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Dater Tract N Address AVA The foll from th I Developer: l l eg "v G/ , Tract Name: Lot No. Is); may- k /iy i ► 9 swing are the requirements for Public Works Clearance to authorize issuance of a building permit Building & 'Safety Department: USTOM HOMES: PROVIDE ITEMS #2, #3, #4 AND #5 BELOW ❖ TRACT HOMES:. PROVIDE ITEMS #1 #2 #3 #4 (AS APPLICABLE) AND #6 B ❖ ('0MMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS .#1 #2 #3 AND #5 BELO (VALLS: PROVIDE ITEMS #7 BELOW I ❖ SIGNS: PROVInF ITFMC itR RFi MAI 1 2 — 3 4 attach Pad Elevation Certificates in compliance .with the approved design elevation for building ad '(m ' aximum allowable deviation of.+/- 0.1 foot). Pad Elevation Certificates must be current Nithin6 months -of current date). If a precise grading plan creates the pad for approval, please, /ithhold green sheet submittal until a Pad Elevation Certificate can be provided. ,ttach'geotechnical certification of grading plan compliance. ,ttach recorded final map showing proposed building locations are legal lots. Atach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, M10 plan & agreement or provide alternative & valid City approved PM 10 plan set reference umber or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) re submitted separately with grading plans & are subject to additional requirements. ttach an approved precise grading plan for the building location(s). AO flood zone developments fill require an approved flood plain development plan. ttach an approved rough grading plan for the building location(s). ttach wall plan & related approved grading.plah. ttach sign layout/plan & related precise grading/landscape plan. I have reviewed and confirmed the requirements listed above as presented: and find the improvements to be suffi±k iently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). ,,ursuant to my findings, abo proje may be released for building permit issuance. RecomnrT1 ended by: Dated: 3/E{ o% Public orks Distribution: W Green Sheet to Building& Safety afety counter (_) Green Sheet to Community Development Declined for approval for reason(s) as follow(s), please correct and resubmit: N City of La Quinta - PM 10 Project Information (< 1 acre per Lot or Infill Project) Page 1 of 3 Form updated & effective 8/25/2005 Project Information Project Contractor: Project Phase-4L ytd!< L Project Phase (Check One): Project Name: - Project Tract Number: Number: ❑ Demolition Lot Number(s): Anticipated Start Date: Anticipated Completion: Project Street Address: Total acres in active construction (< 1 acre per Lot): Project Contact Information Please Note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non- business hours. Name: Title: Company Name: Mailing Address: City: . State: l Zip Code: Primary Telephone Number: 7 3 Fax: 24 Hour Access/Emergency Phone: Cell Phone: PM 10 Certificate Number: G( ❖ Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. PM 10 (< 1 acre Der Lot or' Infill Project) Fugitive Dust Control Plan Page 2 of 3 Plan updated & effective 8/25/2005 This pl i[ shall take into account applicable SCAQMD Rule 403 regulations. Training maybe obtained by contacting SCAQMD (Sharon Zamora - Phone: (909) 396-2183.). This plan .shall consist of the following action items: WATERING: Continuous watering is required to prevent dust and must occur a minimum of 4 mimes daily. Water shall be -applied to dry soils to stop: • -Visible dust emissions over 20% opacity • Visible dust emissions that travel over 100 feet. • Water'source % nch water meter at front (south) side of pad. ❖ EDUCATION: Responsible. Dust Control Individual and key personnel shall attend SCAQMD PM 10 Class and obtain PM 10 certificate number prior to construction activity. •o WEATHER.MONITORING: Wind predictions shall be monitored. ❖ `'IGNAGE: Use Coachella Valley Fugitive Dust Control Plan Handb ook Construction Site Signage {ii uidelines. ' I ❖ . TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If 11'ehicles operate on pad, pad shall be kept firm and moist through hose watering or sprinklers. Fjkugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. '.05 n` ph maximum traffic speed). o ❖ PARKING: Parking is not allowed. on the pad. All vehicles must park on street (at designated areas only). ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public V orks Inspector... (No dirt on public or private roads). Track out shall be cleaned up within one hour of incident. ❖ . C IRT PILES: Dirt piles shall be limited. to 50 cubic k p . c yards and built per California Building Code g krading requirements. Piles shall be kept moist.or covered with tarp material. Larger dirt piles will rl quire stockpile or grading permit: s• FENCING: Provide PM 10 fencing at: perimeter of. public roads and where applicable.. Wood.:slat f(Mcing .can be installed at rear of.'property and return 20 feet on either side if HOA restrictions apply. Block walls can replace.PM10 fencing_ during the construction. phase. ❖ ALIPMENT: Extra hoses and sprinklers• shall be maintained on site. ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall b z applied during excavation or.grading operations also. I _ ❖ DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarpe.d prior to leaving. site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as rE,quired. City of La Quinta - Site Specific Construction Phase PM 10 Agreement Page 3 of 3 Agreement updated & effective 8/25/2005 The signature of the property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to AQMD Rules 403 and 403.1; ❖ Shall constitute and agreement to comply with all project conditions as identified in the approved dust control plan; The property owner (or authorized representative): ❖ Acknowledges that. dust control is .required 24 hours a day, 7 days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or abatement purposes; and ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature of Proberty Owner or Authorized Representative M Printed Name Title Company G 9. 4 Date I . . •` CITY OF LA QUINTA SU-6=CONTRACTOR LIST . .. . :: J , O.WNE'R .1cel !,, ldn6l :. ; g _ Gals G- . . PERMIT NUMBER 1. J0:6 1DDRES:S ` S I,o-ho . is lis th UILD R E ,.- - authorised :to work Torm shall .be, osted .on- the:'ob.... the: Building .Inspection Card at all. times: in a :cotlsai ... ' ' dace. Only persons appearing on -this t . ei em.. gees are This. P i • . + o 'r Ix will result. in a .sto a e ,of. work and(or the' voidance '. :c- ' es to:: - i. list ri U .:be approved by .he :Euild'grg ®ovostc prep..o cotrvr:e ttcere ent o ®rk: 'Fas.!l e.to corn n , P.P 9. . .1. on'this'joli. Y9 :: ' ., , . t °On File" is t .. , I trade II information re ested below must be. completed :b_y appltcan -.: o an; acceptable re pose. . of buildtn. ermtt...For each appl4cab e.._ ,. ._ q.._0 _, : _ _.9 P , ..... ioW_. 3,., r t . _ .. .... ... .- ,...-....... ......-. ... • ....:.... .. - ..- .. ;.. >.:. _.. S.. _ ::::.:. - .. ,:. T m ran:e . > . .... . Date , y.lkense Number Exp Date. " Com :an ;Name ClasSificat on ' : L cegse'Numbe Exp: pate Gamer Name: ' PoGcY'=Number . ExP. ,... . ;. . P Y. ... - . A, B, C .81 txxxxzicl..', (xxlzxlxxl . :Ie.g..State Fund, CalCompl`.: IForto►at`Varies) (xxlx43W . ' Ix'xxxl ' . txx/xx/xx.) . .. ... . - . .. •... - ,':. •... . - .. . . le • : . EARTHWORK.,IC-121` .:: _ .-'...., .. y . ... .. : - ✓ :.: _ ,r.. .. - .. ..: .. C.81 . ..... 6..- c .. tvc t n L . ..:.: .... ,.... , ::..r :. . ..... ....... . ( ca hS :: AMe OUOI : 1 O I o : r . - ~ ►MING •<G 5}. • _ ..: 4 _'., , i, .1.1. ' .' , l :.. ,, :' ::.,.... -.. , .. ,, . - ., .: • . :. e. :. .. ..: , 3.. - .._ ., . S:1 .. 2. o qi 8 .. / ✓ ash . . . :. - _ . ., ,. 1.1. T . ,' :: : _ ... _:.... .. _ _. . - ---, .. - y. _ b :.S 'i: -Y. is .. . - " ..'..:. 3 w. }M -... I y. ya ,-.., , Oi A ., .. .. SONRY- C Ob 29.)...: - , eU V1 1 . . i .- _ W _ .._ _. _. iZ. -• 30 1 2 °I I Io ,. • S'fgTE Lp/r1( erisA ios^ t .... . ,. <. 3 3 3 ;o::. :PhtniNa.9c 1. -r , 3h,-. 51 g/'3t . 1 1. e .:, . a _, - ., . '. 0 O 1,' O -.... ,, :..:'. . m. ,. .:: , . „ - .-: :.. .,t l ::. ►TH/ t?1$TER,Ic.351.. q., lam.. ,! s' 'y. -. .a . . . :.:..,...:.. ..1.., ... --, ... , .,:. .: r1. h // Z/3l ".z s t a. c ::F ,. D. 1o.. S Ll log l ` -. DRYWALL:IG91.:<• .._ { .: I . GJ {.,I . 'P 8 h . , ,G cam._ >:. G , .. ::: a- Go". ns'ra Ov . S'rATe t 3-, :... a: 5. s r1 t, T :- ... Obi b oc-2 cam: [ .t: / o_ °I. 11. _ o :: :: ... r . I..... < :..:...y .. N - 4M y 513 .. -,. . .. ... .- ..,, e.- , , - ... :. :.. ... - :^ .. _... , .:: Sit' oM S o0 0 1 _ Iti1 gz . ... n ,_ _._ :C - _. _,_. _ ...., a. rys R 3 v 3 F P w 0'1 0 ,.. . - cA. ck ;S tH r /A -... ..... /w ., -:•. - '" f. d( 1. 3 .. ♦ , - _ , . .. > cMf j ` . a/ `RQDFtNG_ 03.91:; 1 ''...✓a, r Arse6AA 1 . 2 `l 00'}30 -%2 .,,. ,_..., >.. ; e . t ..._...: > .. :: _ . A M q1 . r. ..-. ,. L _ : ... .. - .. r. ._ .... _, t.. ._.. .. .: q l>o ... - ,. r1 w. ; t •r l spa 3 2: 5 - off: 1 Ar, t W2"i 17$2:-'-1 2(°: X01 l oo` o g _ - '.. ... -4 > "`'i :, ,_ ; : e:. r . : .. 31:1::._ _ HE. META 11x...31 . r,,,..... v ,.H /a..) fi_ .: ..,_.. n. _..f. _ . .,:a..._,.,..._.3_S . _,,. f. :..... - >v ..r- _ ..:.; ,.; .. ori<. ..v... , .: TA' Te ' G!r? GTA f s. _ r .( t7 : h _ , . F= <- j .,. Y • , . , . ,, ,.-....,.. , i i v. . -.. , . -t -.... .. . , .. a. , .... , s ` ,*e c -ja S - :...' - . ..-.-_.. i x, _ GLAZING {.0 ,1.7,1... , /- : _ — _,,,. . , S . 31 l t= gOi`o 1l'F 01 ` _ _, , _..-.. - r "( x>. ,w.a 4 ' t2 - ..t _. z x z T G i F. - t ve A uA, Y . 9 4 a7 P- h_: r G. 6 f•t Y„ S 3 1 . _ s , c. C.O 1Lt, . O ., Cit:01 N u// 4norl:tc:z t <. C..., 1 : oil r , '- - 1✓ .,...• A. .s ... - . p • ,. . -. r .... ., . ... TQ r -•:.,.. :. ,. .:. S _ .. k_. .C o-0°10, $ g:: 3 0- f- l l ` 3 t og z _.. .:_ 8.1 SEWAGE. DIS ..: 1-4 1 _ .. _ >:. ? -.: = f,t., P- t.... G. _ r _fit I. -y., c, - - -• .:,. , " 1..,. x. Lia >:=i. .;,,: ,.... !fir ., s :.. Z i. - - 1 - :ING C-3.3 :.. U t t .G- 3' ( i. 1 - QC v2 7 j.. ? ,. ,. G a T _g G , -r. --,- f l d t ,.- A y . .,_ .: _. S 3.. C?D fi' F re S'f ,t^(' 't A. t ` J , -.. <. is 0 .... .: .. _ 7,.. ...r.. ._ .y rt.., i. _ 7 , a t tr> S7q l i0 :: a . Y r - fRAMIC.1tL> (C 4.1 ; _ , . 4 = ..• .< f ,=05 -. kF - . w f . A _ :..._ . , _ 'It ^. a T/Ra+%e l r: } PiS4iA ::. C '. 3 -. 5 0 _ , ;.. o c .voZ 17f3o off' .a. CABINETS iG- 6) . r a . , mz-.,; v s 1. Q"1 - .. . s. , 30 ,,...., __..>.., , ti.r „ .. , „ .. -. :: Z G . '_13 ... ' r.. S ti G .. .- fENC1N. ,IC_., ,1. ,. /L ::w• . Z .. cS c r . 4 /l- l. , _:Y }. 7• Y y. G :: , ;<. nu i - 1 77 fi :.. ---l.....: . S' 7.pO j 1130 ;iar'c a : . D. AP NG C:271 ..:: , , ,, .. O: Q - P. LAN .0 ... J_.. - ( r.5. :.. .... .. -. .: a.. . 5.. ,. .r.. , .. V E 1000 01lJ 1 ,:.-. . - y_: _ - fl p - i : r ... , ... , .• n d -v, ... ,lam nS _'i. - O 531..., «. _3s:. . ._...... ... - ". - _ % .. _. :. .- c. ,. , a 3 . , 1\x1!1 .: .- .' -. - . , .. . ', - .. ... : .. - .. . , ' 1. .. - - .: , ccupancYcato of -0s -Cert fi: o iif 3 TAt440 OF Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that,^ at the time of *issuance this structure was in compliance with the provisions of the Building' Code and - the various ordinances. of the City • regulating building, construction and/or use, BUILDING ADDRESS: 54-885 AVENIDA MADERO. Use classification: SINGLE FAMILY DWELLINGBuilding Permit No.: 07-005 -Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RC Owner -of Building: M/M WEISSA ddress: 54-885 AVENIDA-MADERO City,,ST, ZIP: LA QUINTA, CA 92253 BY: KIRK KIRKLAND :Date: 08-21-2007 Buildirig Official v ,7 POST IN A CONSPICUOUS PLACE .......... *Vt ; TITLE 24 REPORT Title 24 Report for: SS 5 Mad ro La Quin`ta , CA 92253 Project Designer: LENCH DESIGN STUDIO INC' P O BOX 450 LA QUINTA, CA 92247-0450 760/564-1866 Report Prepared By: VERNA LENCH Lench Design Studio, Inc. P.O. Box 450 La"'Quints, CA 92247-0450 .(760) 564-1866 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: DATE 3 0 BY VL -1415 Date: r The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: VL -1415 User Number: 5454 TABLE OF CONTENTS Cover Page 1. Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 Room Heating Peak Loads 12 Room Cooling Peak Loads 13 } i Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R MIM V1/FISS 2/13/2007 Project Title Date 54335 Madero I a-Quinta Project Address Building Permit # Studio Inc_ (760) 564-1866 _Le❑chD_esian Documentation Author ' Telephone plan Check/Date Fnera)Pro Compliance Method 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.78 1.26 0.53 Space Cooling 72.21 72.11 0.10 Fans 10.16 10.11 0.06 Domestic Hot Water 12.00 9.10 2.90 Pumps 0.00 0.29 -0.29 Totals 96.16 92.87 3.29 F;, Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (E) 90 deg Natural Gas Area: 378 ft 2 Avg. U Ratio: 20.4% Avg. SHGC BUILDING ZONE INFORMATION Zone Name 0.38 0.32 Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 1 835 n nen R_49 R-n_n An 0 Wall Wnnd 89 0.074 13_13 R-4.5 An An Wall Wnnd 35 0.074 13_13 R-4.5 _(LIQ Wall Wnnd 16 n 074 13_13 R-45 An An Door None 24 0.500 Nppe R-0.0 90 qf) Wall Wnnd 472 0.074 R_13 R-4.5 180 90 Wall Wnnd 1nR n 074 R_13 R-4 5 270 An Wall Wnnd Inn n 074 R_13 R-45 1Rn 9,Q Wall Wood 186 0.074 R_13 R-4.5 270 9Q Wall Wnnd 422 0.074 R_13 R-4.5 0 An Wall Wnnd 214 0109 R_13 R -n n An An Wall M/nnd q5 0102 R_13 R-n_n 180 An 3.4% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Units Zone Type Conditioned Gains Condition Y / N Status JA IV Reference 1,857 n/a 0 1,857 10.0 1.00 ft2 ft2 ft2 ft2 ft Thermostat Vent Type Hgt. Area Setback- 2 -nla Location / Comments EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Paae:3 of 14 1 Certoficate Of Compliance : Residential (Part 2 of 4) CF -1 R MIM WEISS 2/13/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 Skylight Front (E) 4_4 0_470 NFRCn 1a NFRC _g0_ 0 New Sky18ht - Dual Glaze ZONE 1 2 Skylight Front (E) 4.4 0.470 NFRC 0_38 NFRC 90 0 New SkOght - Dual Glaze ZONE 1 3 Skylight Front (E) 4.4 0.470 NFRC 0_38 NFRC 90 0 New Skylight - Dual Glaze ZONE 1 4 Skylight Front (E) 4.4 0.470 NFRC 0_38 NFRC 90 0 New Skylight - Dual Glaze ZONE 1 5 Skylight Front (E) 4.4 0.470 NFRC 0_38 NFRC 90 0 New Slight- Dual Glaze ZONE 1 6 Window Front (El 48.0 0_370 NFRC 0_32 NFRC 90 90 New IWC 5300 Vin)l/Low-E ZONE 1 Z Window Left (S) 30.0 0_370 NFRC 0_32 NFRC 180 90 New ILC 5300 Vinyl/Low-E ZONE 1 8 Window Left (S) 13.5 0.370 NFRC 0.32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 6 Window Left _(S) 24.0 0=370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 1_Q Window Rear (W) 96.0 0_370 NFRC 0_32 NFRC 270 90 New IWC 5300 Vinyl/Low-E ZONE 1 11 Window Left (S) 12.0 0_370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 12 Window Left (S) 48.0 0.370 NFRC 0_32 NFRC 180 90 New IWC 5300 Vinyl/Low-E ZONE 1 13. Window Rear (W) 27.0 0_370 NFRC 0_32 NFRQ 270 qQ New IWC 5300 Vinyl/Low-E ZONE 1 14 Window Right (N) 6.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 15 Window Right (N) 4.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 16 Window Right (N) 24.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 17 Window Right (N) 24.0 0.370 NFRC 0_32 NFRC 0 90 New IWC 5300 Vinyl/Low-E ZONE 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Bug Screen Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 105 None No Insulation 26-A1 New ZONE 1 Slab Perimeter 107 None No Insulation 26-A1 New ZONE 1 Run Initiation Time: 02/13/07 07:19:48 Run Code: 1171379988 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page:4 of 14 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R M/M WEISS 2/13/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Gas Fired Heat Pump 0.80 COP Packaged Gas Heat Pump 13.00 COP New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC Ducted Ducted Attic 6.5 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext. Lennox HM61-175P-1 Large Gas Recirc/Time+Temp 1 175,000 48 New 0.95 0.81% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: IVGIIIC. Title/Firm: Address: Telephone: (signature) (date) User Number: 5454 Documentation Author Name: VERNA LENCH Title/Firm: Lench Design Studio, Inc. Address: P.O. Box 450 La Quinta, CA 92247-0450 Telbp e: 760 564-186 =2 ig a ure) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R MIM WEISS 2/13/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the aunyuacy v1 tilt; special Jusuncauon anu uocumemauon suornmea. Plan Field The DHW System "Lennox HM61-175P-1"is a Large Gas water heater with Pilot Loss= 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- _rr• - • • •• r.......o ..—..y --- orr ••• •• LO -411y a1wivI ♦e1nu:auUn meuwus dna illus[ oe reporieu on me Lr-vrc installation certificate. Plan Field The HVAC System "HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Paoe:6 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑X ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor In metal frame walls (does not ❑ ❑X ❑ appy to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ 0 ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑X ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El IR El Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfittration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient ❑ ❑X ❑ (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑X ❑ EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page:7 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑X ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ reductions in the cross-sectional area of the ducts. ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1 9(d) that does not turn on automatically or have an retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment "INKNO 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑X ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. §.150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑X ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑X ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page:8 of 14 Residential Kitchen Lighting Worksheet WS-5R M/M WEISS 2/13/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 22w Fluorescent Circling Rapid Start Yes X NoTI 27.0 x 4 - 108 or (1) 2w Compact Fluorescent Trip/Quad 4pin 04 Yes X No 46.0 x 6 276 or Yes No x or Yes No x = or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x - or Yes No x = or Yes No x - or Yes No x = or Yes No x = Yes No or x = or Yes I No x = or Yes No x = or Yes No x = or Total A: 384 B: 0 z COMPLIES IF A;-)- B YES ® NO ❑ 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE M/M W E I SS 2/13/2007 SYSTEM NAME FLOOR AREA HVAC 1,857 FE-NGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sgft) 35.0 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 31.8 Total Output (sgft/Ton) 377.7 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 0.75 Airflow (cfm/Ton) 284.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 827 25,542 2,517 638 27,654 0 2,598 2,135 0 0 0 0 0 0 0 0 0 2,598 2,135 30 738 2 517 31 925 YORK D1NH060NO6506 48,447 0 65,000 Total Adjusted System Outputa8 447 0 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 68.6 OF 112.2 OF 112.20F O Supply Air Ducts Outside Air 0 cfm 110.8 of Heating Coil Supply Fan 1400 cfm ROOMS 68.6 of 70.0 °F h Return Air Ducts ' (COOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) 111.0 / 77.6 of )0--- ;li Outside Air 0 cfm 79,7/59.7 of 79.7159.70F ® 47.2/45.60F Cooling Coil Supply Fa 1400 cfm 47.2 / 45.6 of — Supply Air Ducts Fan 49.0 / 46.5 of 31.5% R.H. ROOMS 78.0/59.1OF h Return Air Ducts 4 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Paae:10 of 14 1 IROOM LOAD SUMMARY PROJECT NAME M/M WEISS DATE 2/13/2007 SYSTEM NAME HVAC FLOOR AREA 1,857 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 1 ZONE 1 1 827 25,542 2,517 827 25,542 2,517 638 27,654 PAGE TOTAL 1 827 25,542 2,517 638 27,654 TOTAL 1 827 25,542 2,517 638 27,654 EnergyPro By EnergySoft User Number: User Job Number: VL -1415 Page: 11 of 14 .ROOM HEATING PEAK LOADS 71 Project Title Date M/M WEISS 12/13/2007 Room Information Desi n Conditions Room Name ZONE 1 Time of Peak Jan 12 am Floor Area 1,857 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70°F Conduction U -Value Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 21 250 Infiltration: S nedu e0 x Air Sensible x Area Coiling X Calling HeigOhtx ACH 2 6] x QT 44 = 6 404 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,654 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page: 12 of 14 1835.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x X x X x X 0.0200 X X X X X X X X X X x X X X x X X X X X X X X x X X x X X x X X X X X x X x X 44 = = = = = = = = = = = = = = = = 1,615 4.4 0.4700 44 91 4.4 0.4700 44 91 4.4 0.4700 44 91 4.4 0.4700 44 91 4.4 0.4700 44 91 perimeter = 104.9 0.7300 44 3,369 perimeter = 106.7 0.7300 44 3,427 89.0 0,0743 44= 291 48.0 0.3700 44 781 35.0 0.0743 44=114 16.0 0.0743 44 52 24.0 0.5000 44 528 472.5 0.0743 44= 1,545 30.0 0.3700 44=488 13.5 0.3700 44 220 24.0 44=391 106.0 0.0743 44 347 96.0 0.3700 A= 4 1,563 100.0 0.0743 44 327 12.0 03700 44 19.5 48.0 0.3700 44 781 186.0 0.0743 44 608 27.0 0.3700 44=440 422.0 0.0743 44=1 148n 6.0 0.3700 44 98 4.0 0.3700 44 65 24.0 44=391 940 017nn 44 214.01 0,1020 44=QRn 95.0 0.1020 44= Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 21 250 Infiltration: S nedu e0 x Air Sensible x Area Coiling X Calling HeigOhtx ACH 2 6] x QT 44 = 6 404 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,654 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page: 12 of 14 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date WEISS 2/13/2007 -:1 Room Information Desicin Conditions Room Name: ZONE 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,857 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78*FOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CI -TD 1 Btu/hr IR -13 Wall w/1" EPS R-13 Wall w/1" EPS R-13 Wall w/1" EPS R-13 Wall w/1" EPS E 1,835.0 X X X X X X X X X X X X 0.0200 X X X X X X X X X X X X 56.0 E 89.0 0.0743 33.0 N 457.0 0.0743 23.0 E 16.0 0.0743 33.0 E 24.0 0.5000 33.0 S 472.5 0.0743 26.0 (W) 106.0 0.0743 33.0 (S) 100.0 0.0743 26.0 W 186.0 0.0743 33.0 38.3 S 0.0x 19.3+ 30.0X 19.3 S 0.0 19.3 13.5 19.3 S Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration indow FR DR Internal Gain Occu ants B4 E ui ment 1 Page Total Orientation Shaded Area X X X GLF + + + Unshaded Area X X I X GLF (Sky) 0.0X 24.0+ 4.4X 75.4 (Sky) 0.0X 24.0+ 4.4X 75.4 (Sky) 0.0X 24.0+ 4.4X 75.4 (Sky) 0.0X 24.0+ 4.4X 75.4 (Sky) 0.0 24.0 4.4 75.4 E 0.0x 19.3+ 48.0X 38.3 S 0.0x 19.3+ 30.0X 19.3 S 0.0 19.3 13.5 19.3 S 0.0X 19.3+ 24.0X 19. W 0.OX 19.3+ 96.0X 38.3 X Occupants X 230 Btuh/OCC. = X Dwelling Units X 1,600J Watts/sqft = Page Total Btu/hr Btu/hr 920 1,6001 Infiltration: 1.064 X 1. 6 X 117.66 X = 4 949 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,5421 Latent Gain Occu ants ® X Occupants X 200 Btuh/OCC. Btu/hr 800 Infiltration: 4 771 X 1.16 X 117.66 X 1 1,7171 Air Latent CFM ELA p TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,517 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page: 13 of 14 [RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date M/M WEISS 2/13/2007 Room Information Desicin Conditions Room Name: ZONE 1 Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,857 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Surfaces 13 Wall 13 Wall Orientation Area U -Factor CLTD 1 E 214.0 X 0.1020 X 33.0 S 95.0 X 0.1020 X 26.0 X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration SH 4060 XO rage I otal Orientation Shaded Area X x X x X x x X GLF + + + + + + + + Unshaded Area X X X X X X X X Page GLF = = = S 0.0 19.3 12.0 19.3 S 0.0 19.3 48.0 19.3 W 0.0x 19.3+ 27.0x 38.3= N 0.0 19.3 6.0 19.3 N 0.0 19.3 4.0 19.3 N 0.0x 19.3+ 24.0X 19.3= N 0.0x 19.3+ 24.0X 19.3= Total Btu/hr 720 252 972 Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants X 230 Btuh/OCC. = 920 E ui ment X Dwelling Units X 1,60011 Watts/sgft = 1,600 Infiltration: 1.064 X 1.16 X 117.66 X = 4.9491 Air Sensible CFM ELA Z T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,542 Latent Gain Btu/hr Occupants F-41 X Occupants X 2001 Btuh/occ. = 800 Infiltration: 4 771 X 1.16 X 117.66 X 0.00263 = 1.7171 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,517 EnergyPro 4.3 by EnergySoft User Number: 5454 Job Number: VL -1415 Page: 14 of 14