RER (05-2519)
50075 Malaga Ct 05-2519 tl P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&ht-4 4Q" BUILDING & SAFETY DEPARTMENT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ny pplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: i - ), I,'as owner of the property, or my employees with wages as their sole compensation, will do the work, and. the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. B.&P.C. for this reason ` I hereby affirm under penalty of pergl u. work for which this permit is issued (Sec. Lender's Name: Lender's Address: LQPERMIT 3NS,IfRUCTION LENDING AGENCY- -,is a construction lending agency for the performance of the Civ. C.). DITION 2001 CBC - - - - - - --- - - - - - - - - - - WORKER'S COMPENSATION DECLARATION Date: 6/22/05 I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is -.-_yissued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation ' s a car j rand policy number are: Carrier . 1 . 00 Policy Number© certify hat, in the erformance of the work for which this permit is issued, I shall -not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should be ertt& subject to the workers' compensation provisions of Section 3700yf jJVTT5 -QQde, I. sr-li f-Niwith comply with those provisions. WARNING: FAILURE T SECURE WORMERS' COMPENSATION COVERAGE IS UNLAWFUL; A`ND.SHALL SUBJECT AN EMPLOYERTQ_gRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN AD TION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION,3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this -application becomes null and void if work is not commenced _ within 180 days from date ofissuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. sOatature (Applicant or .v.. r. BUILDING PERMIT Application Number: (05-00002519` Owner: Property Address: `-,; X50.0.7-5 MALAGG Q PENNINGTON JILLIAN S APN: 773-380"0"34- - 50-075 MALAGA CT Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIP& JUN 2 2 2005 Other struct info . . . . . C Application valuation: 7445 CffV OF LA QUINTA PINMIDEDEPT Contractor: Applicant: Architect ol Owner -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ny pplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: i - ), I,'as owner of the property, or my employees with wages as their sole compensation, will do the work, and. the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. B.&P.C. for this reason ` I hereby affirm under penalty of pergl u. work for which this permit is issued (Sec. Lender's Name: Lender's Address: LQPERMIT 3NS,IfRUCTION LENDING AGENCY- -,is a construction lending agency for the performance of the Civ. C.). DITION 2001 CBC - - - - - - --- - - - - - - - - - - WORKER'S COMPENSATION DECLARATION Date: 6/22/05 I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is -.-_yissued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation ' s a car j rand policy number are: Carrier . 1 . 00 Policy Number© certify hat, in the erformance of the work for which this permit is issued, I shall -not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should be ertt& subject to the workers' compensation provisions of Section 3700yf jJVTT5 -QQde, I. sr-li f-Niwith comply with those provisions. WARNING: FAILURE T SECURE WORMERS' COMPENSATION COVERAGE IS UNLAWFUL; A`ND.SHALL SUBJECT AN EMPLOYERTQ_gRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN AD TION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION,3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this -application becomes null and void if work is not commenced _ within 180 days from date ofissuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. sOatature (Applicant or .v.. r. LQPERAIIT Application Number . . . 05-00002519 Permit . . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 99.00 Plan Check Fee 64.35 Issue Date . . . . Valuation . . 7445 Expiration Date 12/19/05 Qty Unit Charge Per Extension BASE FEE 45.00 6.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 54.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 26.43 Plan Check Fee 6.61 Issue Date . . Valuation . . 0 Expiration Date 12/19/05 Qty Unit Charge Per Extension BASE FEE 15.00 198.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 6.93 6.00 .7500 ---------------------------------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 4.50 Permit . . . MECHANICAL Additional desc . Permit Fee 24.00 Plan Check Fee 6.00 Issue•Date Valuation . . . . 0 Expiration Date 12/19/05 Qty Unit Charge Per. Extension BASE FEE • 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special Notes and Comments CONVERT GARAGE TO RETREAT. UNDER ` EXISTING ROOF LINE.June 22, 2005 9:32:01 AM JJOHNSON Other Fees . . . . ENERGY REVIEW FEE 6.44 STRONG MOTION (SMI) - RES .74 Fee summary Charged --------------------------- ---------- Paid Credited -------------------- Due Permit Fee Total 149.43. .00 .00 149.43 Plan Check Total 76.96 .00 .00 76.96 Other Fee Total 7.18 .00 .00 7.18 'Grand Total 233:57 .00 .00 233.57 LQPERAIIT CERTIFICATE OF COMPLIANCE Desert Sands Unified School District �2, 0 47950 Dune Palms Road <BERMUDA DUNES U RANCHO MIRAGE Date 6/22/05 La Quinta, CA 92253 %.., INDIANWELLS PALM DESERT No. 27331 (760) 771-8515 I..A. QUINTA . J�O INDIO y7� a Owner Jillian Pennington APN # 773-380-034 Address 50075 Malaga Ct Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 50075 Malaga Ct 198 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 ' Unit 4 Unit 9, , Unit 5 Unit 10 , Comments ' At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500.Sq Feet or Less EXEMPT R This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 198 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Jillian Pennington Check No. Name on the check Telephone 777-9896 ' Funding Exempt I By Dr. Doris Wilson Superintendent Fee collected /exempted by S On MC ilvrey Payment Recd' Over/Under' , Signature G' NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy.- Applicant/Receipt Copy -Accounting, TITLE, 24 Energy'Conservation 'Standards Compliance Repo rit PENNINGTON ADDITION/CONVERSION 50-075 MALAGA COURT LA QUINTA June 10, 2005 "Madlin's Job,Number: 25265A Designer's Name ERIC FRENZEL 77-804 WILDCAT DRIVE - SUITE C PALM DESERT, CA 92211 TELEPHONE (760) 409-8256 CITY OF LA QUINTA BUILDING & SAFETY -DEPT. Madli n S AP oR0 TIO FOR C enterprises Zz vvvvvvv Catherine M. Madlin; Certified Energy Analyst Post Office Box 1443 Palm Springs, CA 92263 Phone 760-322-5004 / 760-323-3644 Fax E-mail: Cmadlin@aol.com i Madli s a enterprises Catherine M. Madlin, Certified Energy Analyst 760-322-5004 / 323-3644 Fax Title 24 Energy Conservation Standards Compliance Report This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin s Enterprises. The building design described in this compliance report is in conformance with the standards as outlined in the attached compliance forms and documentation. 1 Date: June 10, 2005 Job Number: 25265A Designer's Name: ERIC FRENZEL Owner's Name: JILL PENNINGTON Project Name: PENNINGTON ADDITION/CONVERSION Project Location: 50-075 MALAGA COURT; LA QUINTA Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM Certified Energy Analyst Catherine M. Madlin r r NR98-90-544 rr C A B E C R98-90-144 California Association of Building Energy Consultants Post Dice Box 1443 w- Palm Springs, CA 92263 r 1 y Catherine M. Madlin, Certified Energy Analyst , 760-322-5004 / 323-3644 Fax Madli.s enterprises,....,, VVVVVVV DESCRIPTION OF BUILDING COMPONENT MINIMUM COMPLIANCE RE UIREMENTS Job Name PENNINGTON ADDITION/CONVERSION Job Number / File Number ' 25265A Method of Compliance , Micropas V6.1 Computer Simulation Existing -Plus -Addition Calculation Extg Residence Built Under 2001 T24 Code Re Total Conditioned Square Footage 195 S .Ft. Addition Total Glazing % (Floor/Glass Area Ratio) 20.2% (E+A Insulation: Roof / Ceiling - Addition R-38 Batts Roof Radiant Barrier - Addition Required for Compliance Insulation: Walls - Addition R-13 Batts 2x4 Walls Insulation: Floor - Slab on Grade Not Required Insulation: H.VA.C. Ducts / Location / Testing New Ducts: R-4.2 / Attic / No Duct Testing Glazing U -Value / Type: Fixed or Operable Glazing SHGC 0.52, Dual Pane, Low E Coating, Any Frame 0.50 SHGC FRC Tested Values Glazing U -Value / Type: French Doors Glazing SHGC 0.50, Dual Pane, Low E Coating, Any Frame 0.48 SHGC RC Tested Values blazing: Exterior Shading Overhangs as Shown on Plans Thermal Mass Square Footage & % Not Required H.V.A.C. System Type Existing Gas Heating /Electric Cooling Domestic Hot Water Heater Existing Water Heater Other Requirements Applicable Mandatory Measures SPECIAL NOTE: This E+A compliance calculation is based on existing Title 24 compliance calculations dated 9/11/2002 and prepared by Rick Krown. The existing residence was built under the 2001 Title 24 requirements. To facilitate the transition to an existing+addition compliance calculation this house has been calculated at the four cardinal orientations listed in the original report. The file was then modified for the E+A calculation. A copy of the original compliance documents can be found in the Addendums and Notes section of this report. This addition/conversion complies at all orientations and in reverse plan. Please feel free to contact us if you. have any questions or need additional information. ' Title 24 Compliance Forms CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 Project Address 50-075 MALAGA CT ******* LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Madlin's Enterprises P.O. Box 1443 Palm Springs, CA 92262 760-322-5004 Climate Zone.. ..... 15 Compliance Method...... MICROPAS6,v6.0.1_'for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM CF-lR User#-MP0207 User-Madlin's Enterprises Run-E+A CALC t Component Type Wall Wall wall Door RoofRadiant S1abEdge SlabEdge GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type .. Building Front Orientation. Number of Dwelling Units... Number of Stories.. ...... Floor Construction Type.... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC.* Average Average Ceiling Height..... Orientation 2675 sf Single Family Detached Existing Plus Addition Cardinal - N,E,S,W 1 1 Slab On Grade 20.2 % of floor area 0..53 Btu/hr-sf-F 0.48 11 ft i BUILDING SHELL INSULATION Frame Cavity Sheathing Type R -value R -value Wood R-13 R-0 Wood R-21 R-0 Wood R-13 R-n/a None R-0 R-0 Wood R-11 R-27 None R-0 R-0 None. R-0 R-0. Window Front�(N) R-21 Window Front (NE) Window Left (E) Window Left (E) Window Left (E) Window Left (E) Window Left (E) Window Back (S) Window Back (S) Window Back (S) Window Back (S) Window Right (W) Window Right (W), Area (sf) 5.0 5.0 5.0 20.0 25.0 20.0 8.0 64.0 15.0 48.0 25.0 5.0 15.0 Total Assembly R -value U -factor Location/Comments. R-13 0.088 R-21 0.059 R-13 0.850 R-0 0.387 R-38 0.025 F2=0.760 F2=0.510 FENESTRATION U_ Factor 0.520 0.520 0.520 0.550 0.520 0.550 0.520 0.500 0.570 0.500 0.570 0.520 0.570 SHGC 0.500 0.500 0.500 0.460 0.500 0.460 0.500 0.480 0.500 0.480 0.500 0.500 0.500 -Over- Interior Exterior hang/ Shading Shading Fins Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard None None None None None None Yes Yes None None None None None i CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title........... FRENZEL.PENNINGTON.E+A Date..06/10/05,13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC FENESTRATION Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins Window Right (W) 25.0 0.570 0.500 Standard Standard None .Window Front (NW) 5.0 0.520 0.500 Standard Standard None Window Back (S) 48.0 0.500 0.480 Standard Standard None Window Right (W) 25.0 0.550 0.460 Standard Standard None Window Right (W) 20.0 0.550 0.460 Standard Standard None Window Right (W) 25.0 0.550 0.460 Standard Standard None Window Left (E) 30.0 0.550 0.460 Standard Standard None Window Left (E) 10.0 0.550 0.460 Standard Standard None Window. Left (E) 8.0 0.520 •'0.500 Standard Standard None Window Right (NW) 20.0 0.550 0.460 Standard Standard- None Window Front (N) 12.5 0.520` 0.500 Standard Standard None Window Front (N) 12.5 0.520 0.500 Standard Standard None Window Right (W) 4 40.0 0.500 .0.4,80 Standard Standard None SLAB,SURFACES Area-� Slab Type (sf) . Standard Slab 1141 Standard Slab 195 THERMAL MASS Area Thickness' Type Exposed (sf) (in). Location/Comments S1abOnGrade' Yesr 1006 3.5 .Exposed S1abOnGrade No 333 3.5 Covered HVAC SYSTEMS Refrigerant' .Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R -value Leakage D Type Furnace 0.800 AFUE n/a Attic R-4.2 Yes No LivingSta ACSplitTXV 12.50 SEER Yes Attic R-4.2 Yes. No LivingSta Furnace 0.800 AFUE n/a Attic R-4.2 Yes No SleepingS ACSplitTXV 12.00 SEER Yes Attic , R-4.2 Yes No SleepingS Furnace 0.800 AFUE. n/a Attic R-4.2 No No SleepingS ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No SleepingS CERTIFICATE OF COMPLIANCE: RESIDENTIAL " Page 3 CF -1R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM CF -.1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC DUCT TESTING DETAILS Duct Measured Supply r Leakage Target Duct Surface Area Equipment Type fan CFM/CFM25) (ft2) Furnace / ACSplitTXV 6% / 56.2 n/a Furnace / ACSplitTXV 6% / 47.9 n/a WATER HEATING SYSTEMS l Number Tank in Energy Size Tank Type Heater'Type Distribution Type System Factor (gal) Storage Gas Recirc/TimeTemp 1 0.52 7.5 External Insulation R -value R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS I *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing,North. �j This building incorporates a Zonally Controlled HVAC System. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must.be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates a High Mass Design. This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge'and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). J Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters,with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION j *** Items in this section require field testing and/or *** f *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods.and *** *** must be reported on the CF -6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage j values measured at 25 pascals are shown in DUCT TESTING DETAILS above CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4. CF -1R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC HERS REQUIRED VERIFICATION or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow_(RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not i.nstalled., then HERS verification is not necessary for the RCA or.TXV. REMARKS The values and materials used for the existing house energy budget were obtain from the original Title 24 compliance report dated 9/11/2002 and prepared by Rick Krown. To facilitate the transition to an E+A compliance calculation this house has been calculated at the four cardinal orientations listed in the ori - original report. A copy of the original compliance documents can be found in the Addendums and Notes section of this compli- ance report. This addition/conversion complies at any orienta— tion. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord-. ance with industry standards. The load calculation in this report considers only ambient temperature loads, solar heat gain, people and a fixed percentage for latent heat gain. This basic load must be adjusted for additional design conditions and i' system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. ! The HVAC equipment is existing. The water is existing. 1 � 0 'CERTIFICATE OF,COMPLIANCE: RESIDENTIAL Page 5 CF -1R Proiect TitIP__ _ _ _ _ _ _ _ _ FRFM7FT. DrN7MTML`MnM 1,1f% /nr I n _ . r MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC COMPLIANCE STATEMENT, This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance, is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is„indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... ERIC FRENZEL Name..:. CATHERINE M. MADLIN Company. DESIGNER Company. Madlin's Enterprises Address. 77-804 WILDCAT DR STE C Address. P.O. Box 1443 PALM DESERT, CA 92211 Palm Springs, CA 92262 Phone... 760-409-8256 Phone... 760-322-5004 License. Signed.. 0 4L, y 1105- Signed.. (date)- ( ate) F.NFCIR('F.MFNT �CF'M!'V 6 /o as Name.... Title... Agency.. Phone.. Signed.. ( ate) 0 Certified Energy Analyst Catherine M. Madlin r r rr NR98-90-544 C A D f C R98-90-144 California Association of Building Energy Consultants MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-lR Project Title.......... FRENZEL.PENNINGTON.E+A• Dat -e..06/10/05 13:32:45 Project Address 50-075 MALAGA rrn ******* LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA, 92262 760-322-5004 Field Check/ Date Climate Zone.. . ..... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered,by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- *150(a): Minimum R-19 ceiling insulation. er ment 150(b): Loose fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14•and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. J MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- 110-113: HVAC equipment, water heaters, showerheads and er ment faucets certified by the Commission. FjCjjr 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA,or ACCA. 150(1): Setback thermostat on all applicable heating and/or i cooling systems. 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. i 6. Piping insulated between heating source and indirect hot water tank. �� *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed 1. with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape -is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber I addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment . 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. i b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation„ pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth_,.CTZ15S92' Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC piloz l.ignt (Exception: Non -electrical cooking appliances with pilot <. 150 Btu/hr). LIGHTING MEASURES Design-.Enforce- er ment 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchens 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater -switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. F i' i I f' COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 Project Address........ 50-075 MALAGA CT ******* LA QUINTA *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Bui ing Permit Madlin's Enterprises P.O. Box 1443 P an Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC, MICROPAS6 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 4.22 5.74 -1.52 Space Cooling.......... 40.11 38.45 1.66 Water Heating.......... 10.65 10.46 0.19 North Total 54.98 54.65 0•.33 Space Heating... ..... 4.22. 6.21 -1.99. Space Cooling.......... 40.11 36.28 3.83 Water Heating.......... 10.65 10.46 0.19 East Total 54.98 52.95 2.03 Space Heating.......... 4.22 6.54 -2.32 Space Cooling.......... 40.11 37.52 2.59 Water Heating.......... 10.65 _ 10.46 0.19 South Total 54.98 54.52 0.46 Space Heating.......... 4.22 5.74 -1.52 Space Cooling.......... 40.11 37.06 3.05 Water'Heating.......... 10.65 10.46 0.19 West Total 54.98' 53.26 1.72 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 2675 sf Building Type .............. Single Family Detached Construction Type ......... Existing Plus Addition Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 IN COMPUTER METHOD -SUMMARY Page 2 C -2R Ptoiect Title.......... FREN7F.T._PF-NNTNf,T(1N r14�n T-4-- nL /, n 1AL 1 _ A MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC Conditioned Volume....... 29428 cf Slab -On -Grade Area......... 2675 sf Glazing Percentage......... 20.2, % of floor area Average Glazing U -factor... 0.53 Btu/hr-sf-F Average Glazing SHGC....... 0.48 Average Ceiling Height..... -11 ft 5 ! BUILDING ZONE INFORMATION Floor #. of Vent Vent Air Area Volume Dwell Cond- Thermostat Height. Area Leakage Zone Type .(sf) (cf) Units itioned Type (ft) (sf) Credit t 1.ZONE Living 1339 16068 0.50 Yes LivingStat 2.0 Standard No i 2.ZONE Sleeping 1141 11410 0.43 Yes SleepingStat 2.0 Standard' No 3 -ZONE Sleeping 195 1950 0.07 -Yes SleepingStat 2.0 Standard No .OPAQUE SURFACES Area U- -Insul Act Solar Form 3 Location/ Surface (sf) factor-R-val Azm Tilt Gains Reference Comments 1.ZONE - Existing 1 Wall 147 0.088 13 0 90 Yes W.13.2X4.16 3 Wall 95 0.088 13 90 90 Yes W.13.2X4.16 4 Wall 506 0.059 21 90 90 Yes W.21.2X6.16 7 Wall ' 109 0.088 13 180 90 Yes W.13.2X4.16 8 Wall 179 0.059 21 180 90 Yes -W.21.2X6.16 11 Wall 95 0.088 13 270 90 Yes W.13.2X4.16 I 12 Wall 97 0.059 21 270 90 Yes W.21.20.16 16 Wall 44 0.850 13 0 90 No None 20 Wall 19 ' 0.088 13 35 90 Yes W.13.2X4.16 23 Wall 19 0:088 13 325 90 Yes W.13.2X4.16 25 Door 28 0.387 0 0 90 Yes None 26 Door 21 0.387 0 0 90 No None 27 RoofRadiant 1339 0.025 38 n/a 0 Yes R.38.2X4.24. 2.ZONE - Existing 5 Wall 332 0.059 21 90 90 Yes W.21.2X6.16 i 9 Wall 42 0.059 21 180 90 Yes W.21.2X6.16 ! 13 Wall 370 0.059 21 270 90 Yes W.21.2X6.16 ! 14 Wall 238 0.088 13 270 90 Yes W'.13.2X4.16 17 Wall 183 0.850 13 0 90 No None 18 Wall 20 0.850 13 0 90 No. None 21 Wall 36 0.088 13 225 90 Yes W.13.2X4.16 ! 22 Wall 24 0.059 21 225 90.Yes W.21.2X6.16 24 Wall 40 0.059 21 315 90 Yes W.21.2X6.16 28 RoofRadiant •594 0.025 38 n/a 0 Yes R.38.2X4.24 i 29 RoofRadiant 547 0.025 38 n/a 0 Yes-R.38.2X4.24 3.ZONE - New 2 Wall 157. 0.088 13 0 90 Yes W.13.2X4.16 6 Wall 107 0.088 13 90 90 Yes W.13.2X4.16 10 Wall 27 0.088 13 180 90 Yes W.13.2X4.16 15 Wall 70 0.088 13 270 90 Yes W.13.2X4.16 5 0 COMPUTER METHOD SUMMARY Page 3' C -2R Project Title.......... FRENZEL.PENNINGTON.E+A natP__nA/ln/nq 11.11.dq MICROPAS6 v6.01. File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC Surface OPAQUE SURFACES Area U-. Insul Act Solar Form 3 Location/ (sf) factor R-val Azm Tilt Gains Reference Comments 19 Wall 33 0.850 13 30 RoofRadiant 195 0.025 38 0 90 No None n/a 0 Yes R.38.2X4.24 Orientation 1.ZONE - Existing 0.520 PERIMETER LOSSES. Front Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments 1.ZONE - Existing Window Left (E) 31 SlabEdge 44 0.760 R-0 No 32 SlabEdge 44 0.760 R-0 No 2.ZONE - Existing (E) 8 Window 33 SlabEdge 67 0.760 R-0 No 34 SlabEdge 74 0.760 R-0 No 35 SlabEdge 6 0.760 R-0' No 3.ZONE - New Right I 13 Window 36 SlabEdge 43 0.760 R-0 No 37 SlabEdge 3 0.510 R-0 No 2.ZONE - Existing FENESTRATION SURFACES Orientation 1.ZONE - Existing 0.520 1 Window Front (N) 2 Window Front (NE) _ 3 Window Left (E) 4 Window Left (E) 5 Window Left (E) 6 Window Left (E) 7_ Window Left (E) 8 Window Back, (S) 9 Window Back (S) 10 Window Back (S) 11 Window Back (S) 12 Window Right (W) 13 Window Right (W) 14 Window Right (W) 15 Window Front (NW) 2.ZONE - Existing 16 Window Back (S) 17 Window Right (W) 18 Window Right (W) 19 Window Right (W) 20 Window. Left (E) 21 Window Left (E) 22 Window Left (E) 23 Window Right (NW) 3.ZONE - New 24 Window Front (N) Area U- Act Exterior Shade Interior Shade (sf) factor'SHGC Azm Tilt Type/SHGC Type/SHGC 5.0 0.520 0.500 0 5.0 0.520 0.500 35 5.0 0.520 0.500 90 20.0 0.550 0.460 90 25.0 0.520 0.500 90 20.0 0.550 0.460 90 8.0 0.520 0.500 90 64.0 0.500 0.480 180 15.0 0.570'0.500 180 48.0 0.500 0.480 180 25.0 0.570 0.500 180 5.0 0.520 0.500270 15.0 0.570 0.500 270 25.0 0.570 0.500 270 5.0 0.520 0.500 325 48.0 0.500 0.480 180 25.0 0.550 0.460 270 20.0 0.550 0.460 270 25.0 0.550 0.460 270 30.0 0.550 0.460 90 10.0 0.550 0.460 90 8.0 0.520 0.500 90 20.0 0.550 0.460 315 90 90 90 90 90 90 90 90 90 90 90 .90 90 90 90 90 90 90 90 90 90 90 90 12.5 0.520 0.500 0 90 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/6:68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76_ Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0..76. Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 Standard/0.76 Standard/0.68 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC Orientation 25 Window Front (N) 26 Window Right (W) FENESTRATION SURFACES Area U- • I Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC 12.5 0.520 0.500 0 90 Standard/0.76" Standard/0.68 40.0 0.500 0.480 270 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS Window- -Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext ,Ext Dpth Hght Ext Dpth Hght 1.ZONE - Existing .7 Window 8.0 8 8 9 1.5 n/a n/a n/a n/a "n/a n/a n/a n/a 8 Window 64.0 3 5 9 1.5 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES Area Slab Type -(sf) 2.ZONE Standard Slab 1141 3.ZONE Standard Slab 195 THERMAL MASS Area Thick Heat Conduct- Surface. Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments 1.ZONE - Existing 1 SlabOnGrade 1006 3.5 28.0 0.98 "4.60 R-0.0 Exposed 2 S1abOnGrade 333 3.5 28.0 "0.98 1.80 R-2.0 Covered HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type Efficiency. Airflow Location R -value Leakage D Eff 1.ZONE Furnace 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 ACSplitTXV 12.50 SEER Yes Attic e R-4.2 Yes No 0.733 2.ZONE Furnace 0.800 AFUE n/a Attic R-4.2 Yes" No 0.815 ACSplitTXV. 12.00 SEER Yes Attic R-4.2 Yes No 0.733 3.ZONE Furnace 0.800 AFUE n/a. Attic R-4.2 No No 0.743 ACSplitTXV 12.00 SEER Yes Attic R-4.2 No No 0.637 COMPUTER METHOD SUMMARY Page 5 C=2R Project Title.....:.... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 x6.01 File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC Equipment Type 1.ZONE Furnace / ACSplitTXV 2.ZONE I Furnace / ACSplitTXV i I DUCT TESTING DETAILS Duct Leakage Target (% fan CFM/CFM25) 6% / 56.2 6% / 47.9 WATER HEATING SYSTEMS Number in Tank Type Heater Type Distribution Type System Measured Supply Duct Surface Area (ft2) 1 Storage Gas Recirc/TimeTemp 1 n/a n/a Tank External Energy Size Insulation Factor (gal) R -value, 0.52 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be'documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. ***. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates a Zonally Controlled HVAC System. This building incorporates a Radiant Barrier. The radiant barrier must have an emissivity less than or equal to 0.05, must be installed to cover the roof trusses, rafters, gable end walls and other vertical attic surfaces, and must meet attic ventilation criteria. This building incorporates a High Mass Design. This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and -Airflow (RCA) or a Thermostatic Expansion,Valve (TXV) on the specified air conditioning i system(s). . Mandatory Measures require a A-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a"CEC-approved HERS provider using *** *** CEC approved testing and/or verification'methods.and *** *** must be reported on the CF-6R'installation certificate. *** This building incorporates Tested Duct Leakage. Target.CFM leakage. values measured at 25 pascals are shown in DUCT TESTING DETAILS above COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run-E+A CALC HERS REQUIRED VERIFICATION or may be calculated as documented on the CF -6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could.be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning. system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS The values and materials used for the existing house energy budget were obtain from the original Title 24 compliance report dated 9/11/2002 and prepared by Rick Krown. To facilitate the transition to an E+A compliance calculation this house has been. calculated at the four cardinal orientations listed in the ori-' original report. A copy of the original compliance. documents can be found in the Addendums and Notes section of this compli- ance report. This addition/conversion complies at any orienta- tion. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determining the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers only ambient temperature loads, solar heat gain, people and a fixed percentage for latent heat gain. This basic - load must be adjusted for additional design,conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate.with installed glazing values and areas. The HVAC equipment is existing. The water is existing. Maaiin s . V en tawnses Catherine M. Mad1b; Cerlijied Ene,gy Analyst r 760-322-5004 l 323-3644 (fax) ..... H. V.A. C. Load Calculation HVAC SIZING Page 1 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 Project Address........ 50-075 MALAGA CT ******* LA QUINTA ' *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS6 v6.0l for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-E+A CALC GENERAL INFORMATION Floor Area .................. 2675 sf Volume.. .. .... .... 29428 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ LA QUINTA Latitude.. ... ....... 33.8 degrees Winter Outside Design•...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ...... 34 F Interior Shading Used No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Description Opaque Conduction and Solar...... Glazing,Conduction............... Glazing Solar............ ...... Infiltration........ ........... InternalGain ................... Ducts. .... ................... Sensible Load .................... Latent -Load ...................... Minimum Total Load Heating Cooling (Btuh) (Btuh) 27700 14142 10884 9738 n/a 16414 15539 10284 n/a 1675 5412 5225 59536 57478 n/a 11496 59536 68974 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 HEATING AND COOLING LOAD SUMMARY BY ZONE i i . I ZONE '1.ZONE' Floor Area........................ 1339 sf I Volume........:......... 16068 cf Heating, .Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar:..... 9326 5145 Glazing Conduction........ ..... 5843 5228 Glazing Solar .................... n/a 8360 Infiltration ....................... 8485 5615 Internal Gain .................. n/a 1675 Ducts ............................ 2365 2602 Sensible Load......... ......... 26019 28625 Latent Load... ................... n/a 5725 Minimum Zone Load 26019 34350 ZONE 12.ZONE' Floor Area ....................... Volume 1141 sf ........................... 11410 cf. Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 14612 7167 Glazing Conduction ............... 3787 3388 Glazing Solar .................... n/a 6159 Infiltration ..................... 6025 3987 InternalGain. .................... n/a- 0 Ducts..... ............... ... 2442 2070 Sensible Load ............... ... 26866 22772 Latent Load........... .... ... n/a 4554 Minimum Zone Load 26866 27326• a HVAC SIZING Page 3 HVAC ! Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 -13:32:45 ZONE '3.ZONE' Floor Area...... ................. 195 sf Volume ........................... i 1950 cf Heating Cooling Description (Btuh) (Btuh) j Opaque Conduction and Solar...... 3763 1830 Glazing Conduction ............. 1254 1122 I Glazing Solar........ .......... n/a 1895 Infiltration.. ......... ' 1030 681 Internal Gain.................... n/a 0� ' Ducts..... 605 553 Sensible Load........... ....... 6651 6081 Latent Load........ ..........., n/a 1216 Minimum Zone Load I 6651 7298 HVAC SIZING Page 4 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05.13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-E+A CALC GENERAL INFORMATION Floor Area.................:2675 sf Volume.. .. ........... 29428 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ LA QUINTA Latitude.... 33.8 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ... ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Minimum Total Load 59536 . 66039 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility, to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar....,. 27700 14142 Glazing Conduction ............... 10884 9738 Glazing Solar .................... n/a 14191 Infiltration.......... ......... 15539 10284 Internal Gain.: .................. n/a 1675 Ducts ............................ 5412 5003 Sensible Load .................... 59536 55033 Latent Load ...................... n/a 11007 Minimum Total Load 59536 . 66039 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility, to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 5 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE '1.ZONE' j Floor Area ........... ..... .... 1339 sf Volume .................. 16068 cf � - Description Heating(Btuh) Opaque Conduction and Solar...... 9326 Glazing Conduction. ............... 5843 Glazing Solar Infiltration....**......:.....:.. n/a InternalGain........... ....... .8485 n/a Ducts........... ....."....... 2365 Sensible Load....... . .. ..... 26019 Latent Load ................... n/a Minimum Zone Load 26019 ZONE 12.ZONE' Floor Area ....................... Volume.* 1141 sf ............... ......... 11410 cf. " Heating(Btuh) Description Opaque Conduction and Solar.....: 14612. Glazing Conduction.. .. ....... 3787 Glazing Solar.....*. ** ......... n/a Infiltrat..ion..................... 6025 InternalGain......... .. ..... . n/a Ducts ............................. 2442 Sensible Load .................... 26866 Latent Load—, .................... n/a Minimum Zone Load 26866 Cooling (Btuh) 5145 5228 8796 5615 1675 2646 29105 5821 34926 Cooling (Btuh) 7167 3388 3963 3987 0 1851. 20356 4071 24428 HVAC SIZING Page 6 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 ZONE '3.ZONE' Floor Area ....... .............`... 195 sf Volume ........................... 1950 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar:..... 3763 1830 Glazing Conduction............... 1254 1122 Glazing Solar........... ....... n/a 1432 Infiltration ............... .... 1030 681 Internal Gain .................... n/a 0 Ducts ......................... .. 605 507 Sensible Load........... ........ 6651 5572 Latent Load ....................... n/a 1114.. Minimum Zone Load 6651 6686 HVAC SIZING Page 7_ HVAC Project Title.......... FRENZEL.PENNINGTON.E+A 11-19-49; MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-E+A CALC CGENERAL INFORMATION Floor Area......... ...... 2675 sf Volume.. ........... 29428 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ LA QUINTA ' Latitude ................... 33.8 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design....... 112 F Summer Inside Design....... 78 F Summer Range.. .. ..... 34 F " Interior Shading Used....... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 I� HEATING AND COOLING LOAD SUMMARY i Heating Cooling Description (Btuh) (Btuh) ., Opaque Conduction, and Solar...... 27700 14142 Glazing Conduction ............... 10884 9738 Glazing Solar.... .............. n/a 14993 Infiltration ..................... 15539 10284 •� Internal Gain .:.................. n/a 1675 jDucts ............................ Sensible Load 5412 59536 5083 .................... Latent Load ...................... I n/a 55915 11183 i Minimum Total Load 59536 67098 Note: The loads shown are'only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing,, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-E+A CALC HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE '1.ZONE' Floor Area ....................... Volume........................... 1339 sf 16068 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and•Solar...... 9326 5145 Glazing Conduction ..............." 5843 5228 Glazing Solar .................... Infiltration n/a 6999 ..................... Internal Gain ..................... 8485 n/a 5615 1675 Ducts ......................... 2365 2466 Sensible Load. ................... 26019 27128 Latent Load ....................... n/a 5426 Minimum Zone Load 26019 32553 ZONE '2.ZONE' Floor Area.... .................... 1141 sf Volume ........................... 11410 cf Heating Opaque Conduction and Solar...... Glazing Conduction ............. Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts...................... .... Sensible Load...... .......... LatentLoad ...................... Minimum Zone Load 14612 3787 n/a 6025 n/a 2442 26866 n/a 26866 Cooling (Btuh) 7167 3388 5846 3987 0 2039 22427 4485 26913 HVAC SIZING Page 9 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 ZONE '3.ZONE' Floor Area ........................ Volume.. 195 sf 1950 cf I Heating Cooling i Description i (Btuh) (Btuh) Opaque Conduction and Solar...... 3763 1830 Glazing Conduction........... .. 1254 1122 Glazing Solar ..... ........ ... Infiltration n/a 2148 ..................... I. Internal Gain ............. ...:... 1030 n/a 681 0 Ducts ........................ 605 578 j Sensible Load.. 6651 6360 Latent Load ...................... n/a 1272 Minimum Zone Load 6651 7632 HVAC SIZING Page 10 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 MICROPAS6 v6.01 File-25265AD Wth-CTZ15S92 Program -HVAC SIZING User#-MP0207 User-Madlin's Enterprises Run-E+A CALC GENERAL INFORMATION Floor -Area .................. Volume.. ... ........... Front Orientation.......... Sizing Location:...... ... Latitude... ... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside•Design....... SummerRange.. .. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2675 sf 29428 cf Front Facing 270 deg (W) LA QUINTA 33.8 degrees 32 F 70 F 112 F 78 F 34-F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration.......... ............. InternalGain .................... Ducts. .. .. ............... Sensible Load .................... LatentLoad ...................... Minimum Total Load Heating (Btuh) Cooling (Btuh) 27700 14142 10884 9738 n/a 14631 15539 10284 n/a 1675 5412 5047 59536 55516- 5516n/a n/a -11103 59536 66619 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant -design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 11 HVAC Project Title............ FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 i HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE '1.ZONE' A Floor Area.. .. . 1339 sf Volume ........................ 16068 cf ZONE '2.ZONE' Floor Area ....................... Volume.: Heating Cooling Description (Btuh) (Btuh) Opaque.Conduction and Solar...... 9326 5145 Glazing Conduction. ............... 5843 5228 Glazing Solar.......... ........ n/a 8494 Infiltration........ ............. 8485 5615 Internal Gain................. n/a 1675 Ducts.. ,......................: 2365 2616 Sensible Load............ ..... 26019 28772 Latent Load... ..:..... ....... n/a 5754 Minimum Zone Load 26019 34527 ZONE '2.ZONE' Floor Area ....................... Volume.: 1141 sf ....................... 11410 cf Heating(Btuh) Description Opaque Conduction and Solar...... 14612 Glazing Conduction...... ....... 3787 Glazing Solar .................... Infiltration.... n/a .... .... .... Internal Gain...' .. .:........ 6025 n/a Ducts. ................. 2442 ........ Sensible Load........:........... 26866 LatentLoad ................... n/a Minimum Zone Load 268.66 Cooling- (Btuh) 7167 3388 4315 3987 0 1886 20744 4149 24893 HVAC SIZING t Page 12 HVAC Project Title.......... FRENZEL.PENNINGTON.E+A Date..06/10/05 13:32:45 j ZONE '3.ZONE' k Floor Area.... ... .......... 195 sf j Volume.............k.......... .. 1950 cf 0 r Heating Cooling Description (Btuh) .(Btuh) Opaque.Conduction and Solar...... 3763 1830._ Glazing Conduction.. ......... 1254 1122 Glazing Solar ......:........... Infiltration n/a 1821 ..................... InternalGain 1030 681 .................... Ducts ............................ n/a 605 0 545 Sensible Load.. ............. ... 6651 6000 Latent Load ...................... n/a 1200 Minimum Zone Load.' 66.51 7200 f 0 r Addendums and Notes r 1 Addendums and Notes TITLE 24 R ORT , (W00001 le ep r CIE Sa Q 2 Vario s Lo a Qui ; Ca 22 Project Designer:1z•5 + «•o 5egt • ��� kf Ve SEDONA HOMES, INC. 77-564 Country Club Drive, Suite 137 41z, ' Palm Desert, Ca. 92211 j���E REctR.t. ! (760) 772-8224 Report Prepared B : i . Y ��o►� g R Krown CEA 98-93-204 Desert Energy Services P.O. Box 621 Rancho Mirage, CA 92270-0621 IA 6 (760) 770-0044 Certitiod Ener - 9Y Anon Y s .t:: iRkhwd F. ! rr rNR.� r r 98-9&204 CABEC , Job Numbe Wlfar j. nb'Odq"on of 0179-2 CITY GF LA QUI i BUILDING & SAFETY DEPT Date: r�����'f�0VE FOR CONSTRU ON 9/11/2001 �BY DATE The Er gyPro computer Program has been used to authormed by the Catifomia E perform the cakulatlons summarmed in this compliance .This Program has and is gY Commission for use with both the ResldenU and Nonrestderft 2001 8ui tdx►9 Energy Efficiency S'tarxtards. This program developed by Gabe! D0dWEner9ySofk LLC (415) 883-5900. tG% i . E"a'cpyP° 3.1 ey EnergySort Job Number; 017w2 User Number: 2366 i Certificate of Compliance: Residential (Part 1 of 2) CF -1 R HACIENDAS at LA QUINTA PLAN 2 9/11/2001 Project Ste Dats Various Locations La Quinta Project Address Building Permit s Desert Energy Services (760) 770-0044 Ow„ check / Date Doc a entstlon Author Telephone Computer Performance 15 FMW chem f Date Corrrptiance Method (Package or Computer) Curate Zone Enforcement Aaencv Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,480 f? Average Ceiling Height 11.1 ft Total Conditioned Slab Area: 2,480 ft2 Building Type: (check one or more) ® Single Family'Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Frame Const. Assembly Location/Comme Slab On Grade n/a a Sib On Grade _ r a 0.756 rdelAttic/R-38/Gvg Wood 0.029 R-13 Waft (W.13.2x4.16) Wood 0.088 Solid Wood Door Wood 0.387 R-21 Wd (W21.2x6.16) Wood 0.059 R-13 Partition Wood 0.085 FENESTRATION Covered Slab w/R-0.0 Perimeter InsutaUon Exposed Slab w/R-0.0 Perimeter Insulation Exterior Roof Exterior Wall FAerior Door E)dedor Wall EAerior WaH W190WININ VCYIUWO Type Orientation Area Fenestration Exterior OverhangSide Fins S Shading Yes /.No Yes / No FFroO 5.0 0.52 0.50 Bug Screen ❑ ® ❑ Front 5A 0.52 0.50 Bug Screen ❑ Q ❑ x❑ Left _6.0 0.52 0.50 Bug Screen ❑ ❑ Left 80.0 0.55 0.48 Bug Screen .-® ❑ X❑ ❑ Q Rear 64.0 0.50 0.48 Bug Screen © ❑ ❑ Rear 15.0 0.57 0M Bug Screen ® .❑ ❑ Rear 96.0 0.50 0.48 Bug Speen ❑ © ❑ Rear 2$.0 0.57 0.50 Bug Screen ❑ Q ❑ Q RiaW 5.0 0.52 0.50 Bug Screen ❑ Q ❑ O Right 40.0 0.57 0.50 Bug Screen ❑ xQ ❑ O Front 5.0 0.52 0.50 Bug Screen ❑ X❑ ❑ O Rlunt 70.0 0.55 0.48 Bug Screen❑ O ❑ X❑ Run lnRWlon Time: 09111jol 16:51:sA Run Code: 1000249714 LEmMyP, 3.1 By Eneruvsoft User Number. 2366 Job Number: 0179-2 Pow.3 of 17 %oV1 11L;C1L= UI `vVillplialrlva. HACIENDAS at LA QUINTA, PLAN 2 9/11/2001 ` Project Title Date HVAC SYSTEMS Note: Input Hydronk or Combined Hydronk data under Water Heating systems, except Design Heating Load. Distribution Equipment HeatingType Type heat Minimum and Dud or (fumace, Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments E rAwdral FimianA w` Central Furrtare i 80'!6 AFUE nucts. in Attic 80% AF1_JF nirtn in Attic. 4.2 42 Sefback Snthadr LIVING 70NE SI FFPINr±70NF Cooling Equipment Minimum Dud Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R Value Type Comments Split Air Conditioner Split Air Conditioner 1 R nulls in Attic 12 n SFFR nucin to Attic 42 42 = Setback Setback II MNG 76NF Al FFPINC: 70NF WATER HEATING SYSTEMS Rated ! Tank Energy Fad.! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (e%) R Value STATE PRV 7S NRVT1 Small Cao Reckr.Mma+Temn L_ 75171M _7 n_52 n/a - 12 1 For small gas storage (need Inputs of less than or equal to 75,000 DtWhr), eleebic resistance and haat pump water heaters, list energy factor. For targe gas storage water heaters (rated input o! greater than 76,000 Dfulhr), fiat Rated Input, Recovery EfRaiency and Standby Loss. For instsrdansous gas voter heaters, Rat Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building f wWres and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be b uUt in multiple orier>ffitlons, any shading feature that Is varied is indicated in the Special Features/Remafks section. Designer or Owner (per Businew s Professions Code) Documentation Author Name: -ze _ Name: R Known CEA S%4nC -2N Title/Firm: SEDONA HOMES, INC. Title/Firm: Desert Energy Services Address: 77—se4 Country Club Drive. Suite 137 Address: P.o. sox 621 Palm Desert, Ca. 92211 Rancho Mirage, CA 9227040621 Telephone: (Iso) 7728224 Telep e: M 77040044 Lig. # 42- (signature) � (date) nature) ( e) Enforcement Agency Name: _ Ti le/Firm: _ Address: Telephone: 3.1 Ey En ergySoR User Number. 2366 Job Number: 017%-2 Psge:6 of 17 certificate of Compliance: Residential kP%UU_ 14uI I I HACIENDAS at LA—Q-V-LNTA, PLAN2 nate Project TRW Special Features and Modeling Assumptions in this ctmedcfist These Reams require special The local enforcernent agency should pay special attention to the Ran ms specified written justification and cnanentation, and speclal verification to be used with the perfornance aperoach, The equal entorce,finent agency deterrdnes the adequacy of the justification, and mse kro may reject a bu8ding or design itmat o"wrwtmpties Pian Reid based on the adequacy of the special justir"tlon and docurrmenQation submitted. tThe" SystemSTATE PRV 75 NRVT1" Energy Factor = 0.520. An EF below 0.5B requires an R-12 EmGerrmai Blanket• VAC Systerm "LMNG ZONE" must meet aN CEC Criteria for a Zonally Conholled sshnon Livi Areas. LIVING ZONE' induces credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. VAC System " roe. Etc. HIGH MASS Design(s�ee C -2R) - Verity Them�al :333 sqR Covered Stab Floor, 3.SQ' thick at LlvingliQt/D HIGH MASS Design (we C -2R) - Verily Thermal Mass: 1006 sgft E)posed Slab Floor, 3Wthick at Lh*#I6t/Droe. Etc. Time HVACSystem 'SLEEPING ZONE' must meet all CEC Criteria for a ZOnaIIY Controlled ern sWng w4S Areas. The HVAC System -SLEEPING ZONE' includes credit for a Radiant Barrier instaW nu Section 8.13 of the Residential Manual- The Verity Thermal Mass: 578 sqft Covered Slab Floor 3.57 Urick at Maser r Sul6e - Verify Thermal Mass: 16 Nft Exposed Slab Floor, 3.50" thick at mauwSuite - Verify Thermal Mass: 493 sgft Covered Slab FW, 3.50" thk:k at Guest Bedrooms - Ver fv Therml Mass: 54 sgft Exposed Slab F[w, 3.97 thick at Guest Bedrooms I HIGH MASS HIGH MASS HIGH MASS HERS Required Verification of a CEC approves Huts These features must be conitmied arWor testes by a k rtifled HERS rater under 9 tP aiOnrmeasures on a tam CF 8R. provider. The HERS rater must document the field verification and diagnostic - a , r �4 .,..,,1640 ;ystem'LIVING ZONE' incudes Refrigerant Charge and Airflow Credit (Ora of the TXV, or measure the Refrigerant Charge and Airflow. dud Iaakage to con * and must have diagnostic site tesimg of duct leakage The HVA ` C System "LIVING ZONEis using reduced on a CF -6R Fore. performed by a certified HERS Rater. The results of the ditnosdc testing must be reported The HVAC System "SLEEPING ZONE" incudes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide veififlcatim of the TXV, or measure the Refrigerant Charge and Airflow. The rrvAk: ayscern ��«�,••� �....-- — --..-� --- ng must be reputed on a CF -611 Form. performed by a certirred HERS Rater. The resuft of the diagnostic testi 3. Usti Number: 2366 Job Number: 0179.2 of 17 Gomauter Method Summary _ (Part 1 0) C -2R _HACIENDAS at LA QUINTA PLAN 2 Project Title Various Locations La Quinta Address Desert Energy Services (760) 770-0044 ocuerentatlon Author Telephone Computer Performance _ 15 cmnnuniwe MeRma arackade or Comutall chrrate Zone 9/11/2001 Daft Building Permit # Rdd e Source Energy Standard Use (kBtu/sf--yr) Design Facing North Margin Thermostat Facing East Mar in Zone Name 111 NG ZONE Facing South Mar in Zone Type Type acing West Margin _16pBg A 1 141 11 410 4_ 3.11 0.66 3.68 0.08 3.95 -0.19 3.19 0.58 Space Heating 3.77 Space Cooling 39.72 Domestic Hot Wager 11.45 35.89 3.83 11.5 0.20 33.44 6.29 11.25 0.20 34.60 5.12 11.25 0.20 34.57 5.15 11.5 0.20 1 50,95 4-69 Totals 54 CIA BUILDING COMPLIES This C -2R summarizes the results of a four candmal orientation analysis. Tne pages mac roum aesc noe me rrom swig none—urcmm. This plan has been � zzeedd w th identical natures in ell orientations. GENERAL INFORAAATION Conditioned Floor Area: 2,480 Floor Construction Type: Q Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Total Conditioned Volume: 27,478 Number of Stories: 1 Slab Floor Area: 2,480 j BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name 111 NG ZONE Floor Area Volume Units Zone Type Type Hgt. Area _16pBg A 1 141 11 410 4_ r hft I naastm Steri n ��.Ie�pInQ.SfaL_ —2 n1a. —2 . iia 41 FFPtNG ZONE i OPAQUE SURFACES Solar Act Gains Tvoe Area U Val. Azm. Tilt Y / N Form 3 EnemvPro 3.1 BY EnwgvSa User Number: 2366 Job Number. 0178-2 Pne:8 of 17 i Project Date 9/11/2001 Type 1.5 Area Factor SHGC Glaring type 9.0 9.0 1 S 0.0 98.0 Am Tot Comments 2 Window Front (Northea) � WlMkDW 5.0 0.520---a --gn And - -;L Left 4 Window Left ( adl (EW) 5.0 200 Q•a2 0550 --0� --35 90 Lpw E NonMtl Ci r Defaul, --�Low E ClearDefeult F �"'�•••• Window LeR fF�+�4 0.520 90 Low E Non Mtl Clear DefauR �'L IdLindow eR f adi - -�� _ _W L ow E N MW Clw rte„R L IdQ>x�,r__�gft rF,.�+, -.iiLQ 0.59 0.48 F,im/rl►_1 _>`� _.�Q --�' 8 Window Rear � Wmdow RNs _ (South) 64.0 a 0.500 �� 0•'� �ltrrf/(`I I► � �mlGU_t 90 Low E NonMU Cleat Defsutt Finn �rU-1 -0-48�� _ 1 nnv E NO.^�w� r.��- -- -_� - Stlm[; / 11_1 is lA6ndow R�M--'�`� 0 52D -�� -� F��mM.t1_1 -�1Q - _9Q Low E NonMtl Clear Deftun 1 -lw� front --Ula -D= -�_ -EUmMU_1 ~NonMtl ^- 1Z Wtrl- F lNe.f►, 1!3 1m[t w Rear (S +►+� 25.0 0 -Q`� 0 --Q'� �� -� L&1N E --- �� Ct�r DetauR Low E Rpt (West 1$ Window 4B 0 25.0 0.550 - O - _ _94 NonMtt Clear Default FLmrCU-t - 2 Richt M!ALm ) 2p.0 o O`�p 0.48 - � Lcw E NonFA CI i rbc �w �um/CU-2 270 _o Low E Nont1AU Clear l�efa ow Left Window Left (East) East) 30.0 10.0 _0 0.560 O-Wo0.48 -Q.8 0.48 - -�LIM 1.721 90 90 how E NonMU Cl�r Default.222 LeR lF� 8-O Oma% 90 Low E NonhMl Cl�r Default a Rloht (Northwest ) ?a•0 0 �� 0.48 --- _ go -2 315 �ia,Urt 1.7 _ _ 90 Low E NonMU Clear DefauR �lf-2 INTERIOR AND EXTERIOR SHADING Exterior Shade T 1 Bua Sr�oan e SHGC JouwowD•rerfiana Hpt. - Left Fin Wd. Len. Nit Ica SF=* -- - Rl d Fin 2 i- 4 5 6 7 8- 9 10 -11- 12 112 13 74 15 16 17 18 19 20 21 2. 23 B B Bug Scr'se" eua Screen eua Screen Bua 1= Bug Screen Buo ScrH+n Screen Bu0 Screen BuB Screen Bua Sawen 9ua Screen xw _a e Bue Screen 3.1 0.76 0.76 0.76 --QM 0.76 0.76 0.76 0.76 0.76 0.76 a76 0.76 0.76 0.76 0.76 0.76 0.78 0.76 0.76 ---9-76 0.76 User 8.0 8.0 5.03.0 Job Number. 01742 of 17 1.5 4.0 990 9.0 9.0 1 S 0.0 98.0 Job Number. 01742 of 17 • I , I • 4Inside Computer Method Summary HACIENDAS at LA QUINT& PLAN 29/11/2001 Project Title THERMAL MASS FOR HIGH MASS DESIGN r Area Thick. Heat Type (sf) (in.) Cap. Cond. Form 3 Reference (part 3 of 3) C_2A Date Location R -Val. Comments % Concrete malah1 —rn �� —Z MM n/a —2 FtmJCl l-1 / Slah an Grades n/a Fur/CU-1 /Slab on Grade x: tincretp Hea ts 33.50 --Z�� fV3 M _Q F / L /Slab go rade Ste. H 9M —1fi _Z �� n/a —2 Fum/CU-2 / Slab on Orale concrete— 3350 _ M �;� n/a _ 2 2 _Fum/CU-2 / Slab on Grade !! f PERIMETER LOSSES j F2 insulation I Type Length Factor R -Val. Depth Location / Comments Slab Perimeter —44 JIM o_o _II Fum/Cl1-1 Slab Perimeter _ 44 JIM _pQ _II FrmUCU-i Slab Perimeter —�� 0.0 —Q Fum/CU-2 Slab Perimeter --14 47� _DQ —Q Fun/CU-2 Slab Perimeter _6 0.76 0 Fum/CU-2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyand Location Duct Thermostat Location / pump, etc.) (AFUE/HSFxducb/attic etc) R -Value Type Comments Central Furnace 8p% AFLi Ducts In Attic 4Z Setbark Santral Furnace 80%AFUE Ducts in Attk 4.2 Setback LIVING ZONE SLEEPING ZONE Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split AirCnmiitlener 1Z51MER Duds in Attic 42 gethark LIVING ZONE SWit Air Cm bollen 12.GSEER Ducts to Attic 4.2 Setback si FEPING ZONE WATER HEATING SYSTEMS Ratedl Tank Energy Fact? ? Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy R -Value System Name Type Type Syst (Btu/hr) (gaq Efficiency Loss (°r6) Ext. STATE PRV 75 NRVT1 Small Gas Recirctlime+Temn 1_ 75.000 75 052 n/a 12 1 For small gas storage (rated Input v 75000 &u/hr), electric resistance and heat pump water treaters, fid energy factor. For large gas dorape wafer heaters (rated input > 75000 81u ), list Rated Input, Recovery Efticlency and Standby Loss. For instantaneous gas water heaters, Rd Rated Input, and Reoovery Efficiency.