Loading...
MECH (14-0376)50970 Mango 14-0376 P.O. BOX -1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ----------- Application Number: 14-00000376 Property Address: 5D.9.7.0_MANG,O APN: 772-192-008- - Application description: MECHANICAL Property Zoning: LOW DENSITY RESIDENTIAL. Application valuation: 12500 Applicant: J Architect or E/ 'Y el ' BUILDING & SAFETY DEPARTMENT BUILDING PERMIT -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licer LicenseNo.: 489046 Date:( -1l Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the fallowing reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and r the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/07/14 Owner: STEVE ZELL 50970 MANGO LA QUINTA, CA 92253 Contractor: !U ESSER AIR CONDITIONING & HTG/ P.O. BOX 1636 C1? CATHEDRAL CITY, CA 92235 P/A. .,' t.q (760) 324-0550 1U/ / Lic. No.: 489046 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier CASTLEPOINT NTL Policy Number WSLTH • 90140304 I certify that, in the performance of the work for which this rmit is ed, I shall not employ any person in any ms to becom subject to the wor ers' compen tion laws of California, and agre that,ecome su ject to the workers' ompensation rovisions of Section 37Q of he Lashall fort it comply with rhos provisions. Date: I JAplicantC. WARNING: FAILURSECURE WORKERS' COMPENSATION COVERAGE NLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATI , AMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is ommenced within 180 days from date of issuance of su 't, or cessation of work for 0 day 'It subject permit to cancellation. certify that I have read this ap )'cation and state tha he above in o(pu ion ' correct. I agree t comply w th all city and o my ordinances nd tate laws relating to uilding constr, a d hereby authorize re resent ryes of this un y ter u o i t above-mentioned pr perty for inspe poses. Date: Signatu (Applicant or Agent): Application Number . . . . . 14-00000376 Permit . . . MECHANICAL 2013 Additional desc . . Permit Fee . . . . 143.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date . . 10/04/14 Qty Unit Charge Per Extension 2.00 35.7500 EA MECH FURNACE 71.50 2.00, 35.7500 EA MECH CONDENSER/COMP 71.50 ---------------------------------------------------------------------------- Special Notes and Comments (2) HVAC & HEATING UNITS (1) 5 TON 14.5 SEER SPLIT.(1)3 TON 16 SEER UNIT GAS ELECTRIC.SPLIT SYSTEM [2010 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013CBC. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG-STDS ADMIN (SB1473) 1.00 PERMIT ISSUANCE M/P/E 90.57 PLAN CHECK, MECHANICAL 95.32 Fee summary Charged Paid Credited Due Permit Fee Total 143.00 .00 .00 143.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 186.89 .00 .00 186.89 Grand Total 329.89 .00 .00 329.89 LQPER1111T 6in # City of La Quinta Building &r Safety Division P.O. Box 1504,78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # l Project Address: b Owner's Name: Ce A. P. Number: Address: 7 Legal Description: Contractor: City, ST, Zip: n <<<>< Tele;:.>:;::•<: h n #'.<•.»?>`« p o e. Address: C) Project Description: City, ST, Zip: CC Telephone:h V 3 .............................................. State Lie. # : gC7C)L City Lie. #.: Arch., Engr., Designer: ' Address:/u City,, ST, Zip: Telephone: P Construction Type: Occupancy: YP P Y: Project hPa (circle one):: New Add'n Alter Repair air De m 0 a i.# St to Lie. . Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone #,of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE 9 Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates, Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsrissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permif Fees Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Pa e 1 of 5 Project Name: Climate Zone # # of Stories Steve Zell 1 15 1 General Information Site Address: 50970 Mango La Quinta CA 92253 Enforcement Agency: La Quinta, City of Date: 4/4/2014 Building Type 1] Single Family ❑ Multi Family Circle the Front Orientation: (1), E, S, W, or degrees Conditioned Floor Area (CFA): 1100 Project Type: [Z] Alterations [I Envelope El Fenestration ❑Roof ❑ HVAC Re lacement or Change Out ❑ Duct Replacement ❑ Water Heater NOTE: This form is not to be used for Newly Constructed Buildings or Additions Insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below) Assembly Alteration ❑ Opening of framed cavity alone— Alterations that involve the opening of the framed cavity ofa wall, ceiling, or floor must install the mandatory minimum insulation value per §150 for the altered assembly. Fill in Columns A —C and enter mandatory insulation value in Column H. ❑ Replacement of entire assembly— Replacement ofan entire wall, ceiling, orfloor assembly requires the installation of Component Package- D insulation values in Table 151-C. Fill in Columns A —J. Opaque Surface Details For the furred portioned of Mass Walls see Furring Strips Construction Table below. A B C D E F G H I J Proposed SmNote Standard Values From JA4 Table Tag/ IDS Framing Thickness, Framed Continuous JA4 Proposed Assembly Name Material Spacing, U- JA4 Table Cavity Insulation Assembly Assembly or Typel and Size2 or Othe? factor° Numbers R-value6 R -Value? Cell Value U-factor9 Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Note: For furred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and Furring Construction table below. 1. For Tag/]D indicate the identification name that matches the building plans. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate the Frame type and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC; or Other for all other assembly description such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel and etc.... 4. Based on the Climate Zone; enter the Standard U factor from Table 151-B, C or D for each different assembly Name or type. 5. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0 ". 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0". 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J 9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply. Furring Strips Construction Table for Mass Walls Onl A I B I C D I E F I G N I J K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Joint Appendix Table 4.3.5, 4.3.6 4.3.7 Joint Appendix Table 4.3.13 8 a; r y = Assembly R ] 'v.. g • H H i; m > a> > o Final Mass Name or JA4 Table % 3 c Assembly Thickness Type, Number' ¢ > _ ¢ > U-factor6,7 Comment Registration Number: Registration Date/Time: 2008 Residential Compliance Forms HERSProvider: CBPCA August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations age 2 of 5 Project Name: Climate Zone # # of Stories Steve Zell 1 15 1 ass and Furring Strips Construction(footnotes) 1. Indicate the type of assembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can be found Reference Joint Appendix JA4. 2. This is the U -Factor based on the thickness of the assembly in inches. 3. The R -value of the insulation to be added on the interior or exterior of the assembly. 4. The Calculated R- Value is the R -value of the furred out section of the assembly. -6. The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix J44. The equation is the inverse of Column added to Column L Column K is the inverse from column J. 7. Insert the calculated U- actor value on to the Opaque Sur ace Details in Column J FENESTRATION PROPOSED AREAS ❑ Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. The Total Fenestration and West facing Area requirements are not applicable. ❑ Adding 50ft or less of window area — Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. ❑ Adding more than 50ftz of window area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -IR -ALT Orientation Fenestration Type and Frame (North, East, PropsedArea' Maximum Maximum NFRC or Default indow,Glass Door orSkylight) South, West) (ft U-factotz•3 SHGC 3'4 Values 1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration area may be the glass area plus a "2 inch frame"around the glass. 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF -6R -ENV Form shall be equivalent to or have a lower U factor and/or a lower SHGC value than that specified on the CF -IR ALT Form. 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading. 5.I applicable at this stage enter NFRC" for NFRC Certi ped windows or are CEC "De ault" values found in Table 116-A or B. ALTERED FENESTRATION ALLOWED AREAS (Complete if more than 50ftz offenestration is added) A B C D E F G Allowed Existing Fenestration Total Area CFA of Entire %of Fenestration Area Fenestration Allowed Proposed Areal Dwelling CFA Area Removed Area Added A x B) (E -D) + C Total Fenestration Area 20 West Fenestration Area (Required In .05 > CZ's 2,4&7-15 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12. 2. West facing glazing area removed cannot be "counted" twice. " In order to distribute the west glazing area removed to the other orientations, input the west glazing area removed in the Total Fenestration Area row, column D. 3. Include the Proposed Area of the West facing fenestration in both Area columns below. 4. To meet compliance, the Proposed Area must be less than orequal to the Total Allowed Area or BOTH the Total and West Fenestration Areas. Registration Number Registration Date%Time: 2008 Residential Compliance Forms HERSProvider: CBPCA August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 3 of 5 Project Name: Climate Zone # # of Stories Steve Zell 1 15 1 ROOFING PRODUCTS (COOL ROOFS) §1511912 When the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1,000f?, whichever is less, the new roofing area must meet the roofing product "Cool Roof" requirements of §152(b)1Hi, 152(b)1Hii, or 152(b)1Hiii. Check applicable alternative or exception below if the roof alteration is exempt front the roofing product "Cool Roof' requirements. Note: If any one of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in §118(1) are not applicable. Do not fill table below. ❑ Cool Roofs Not Required in Climate Zones 1-12,14, and 16 with a Low Sloped. Less or 2:12 pitch. ❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less than 51b/112. Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12) ❑ Insulation with a thermal resistance of at least 0.85 hrftz•°F/Btu or at least a 3/4 inch air -space is added to the roof deck over an attic; or ❑ Existing ducts in the attic are insulated and sealed according to § 151(010; or ❑ In climate zones 10, 12 and 13, with 1 flof fiee ventilation area of attic ventilation for every 150 fl of attic floor area, and where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or ❑ Building has at least R-30 ceiling insulation; or ❑ Building has radiant barrier in the attic meeting the requirements of §151(f)2; or ❑ Building has no ducts in the attic; or ❑ In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic. Exception to §152(b)1Hiii, Low -slope roof (pitch <_ 2:12) ❑ Building has no ducts in the attic. Other Exceptions ❑ Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria. ❑ Roof constructions that have thermal mass over the roof membrane with at least 25 lb/W is exempt from the below Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, Check the applicable box below if Exem t from the Roofing Products "Cool Roof' Re uirement: Roof Slope Product Weight Product Aged Solar Thermal CRRC Product ID Numbeir < 2:12 > 2:12 < 51b/112 > 51b/112 Type 2 Reflectance3'4 Emittance SRIS ❑ 1 ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.ore/products/search.nhn 2. Indicate the type ofproduct is being used for the roof top, i.e. single ply roof, asphalt roof, metal roof, etc. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+01(pinitial — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. Calculate the SRI value by rising the SRI- Worksheet at h!te:lAvlvlv.enerey.ca.Zovltitle24/ and enter the resulting value in the SRI Column above and attach acopy of the SRI- Worksheet to the CF -1R. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating❑ Cement -Based Roof Coating Other Registration Number: Registration Date/Time: 2008 Residential Compliance Forms HERS Provider: CBPCA August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 4 of 5 Project Name: Climate Zone # # of Stories Steve Zell 1 15 1 HVAC SYSTEMS - HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be gas or propane fired, and may not exceed 50 gallons. Hot water pipe insulation from the DHW heater to the kitchen(s) and on all underground Minimum Duct or Piping Configuration Heating Equipment Efficiency Distribution insulation Thermostat (Central, Split, Type and Capacity 1.2,3 AFUE or HSPF Type and Location° R -Value Type Space, Package or Hydronic Furnace, AFUE Ducted, SetBack Split Energy Factor or Insulation Type' 1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.) 2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity < 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception. 3. Refer to the HERS Verification section on Page 4 of the CF -IR -ALT Form for additional requirements and check applicable boxes. 4. Indicate Type or Location (Ducts, Hydronic in Floor, Radiators, etc.) HVAC SYSTEMS - COOLING Minimum Efficiency Duct or Piping Configuration Cooling Equipment Type and Ca aci 1,2 (SEER/EER or Distribution COP) Type and Location3 Insulation R -Value Thermostat (Central, Split, T e Space, Package or H dronic AirConditioner, SEER Ducted, SetBack Split 1. Indicate Cooling Type (A/C Heat pump, Evap. Cooling, etc) 2. Refer to the HERS Verification section on Page 4 of the CF-/R-ALTForm for additional requirements and check applicable boxes. 3. Indicate Type or Location Ducts, H dronic in Floor, Radiators, etc. WATER HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be gas or propane fired, and may not exceed 50 gallons. Hot water pipe insulation from the DHW heater to the kitchen(s) and on all underground hot water pipes is required in all mponent packages in all climate zones. External Tank Water Heater Type/Fuel Distribution Type Number In Tank Energy Factor or Insulation Type' (Standard, Recirculating)2 System Capacity (gal) Thermal Efficiency R-Value3 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do not allow the installation of a recirculating water heating system for single dwelling units. 3. The external water heating lank andpipes shall be insulated to meet the requirements o 150 ' . SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These items may require written 'usti ication and documentation and special veri ication. NEW ROOF ASSEMBLY - Radiant Barrier The radiant barrier requirement of §151(02 does not apply to roof alterations. Slab Edge (Perimeter) Insulation ❑ YES ❑ NO YES: In Climate Zone 16 in Component Packages D, R-7 insulation is required. Heated Slab insulation ❑ YES El NO YES: Slab edge insulation required for all heated slabs in all Climate Zones. See details in Table 118-A of the standards. Raised Slab Insulation ❑ YES 0 NO YES: In Climate Zones 1, 2, 11, 13, 14 & 16, R-8 insulation is required; in Climate Zones 12 & 15, R-4 is required under component Package D. Thermal Mass To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach. Registration Number: Registration Date/Time: 2008 Residential Compliance Forms HERSProvider: CBPCA August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations age 5 of 5 Project Name: Climate Zone # # of Stories Steve Zell 1 15 1 HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final inspection. Duct Sealing & Testing HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned space, the ducts are to be sealed per §I52(b)iDii and the newly installed ducts are to be insulated per §151(f)l0. ❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the ducts are to be sealed per §I52(b)1Di. El YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be sealed per §I52(b)IE. ❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. ❑ EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. ❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Refrigerant Charge -Split System HERS verification is required for this measure. 0 YES ❑ NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat exchanger) a refrigerant charge measurement shall be verified per § 152(b)l F. Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw The ventilation requirements of §150(o) do not apply to existing residential homes. Ducted Split Systems -Air Conditioners and Heat Pumps: Airflow HERS verification is•required for this measure. ❑ YES ❑ NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is replaced, the airflow and fan watt draw shall be verified per §152(b)1Ci to meet therequirements of §15l(f)7B. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. Name: Tim Esser Signature: Tim Esser Company: Esser Air Conditining Date: 4/4/2014 Address: If Applicable ❑CEA or ❑CEPE 36665 Bankside Dr,Drive OFC,OFFICE (Certification #): City/State/Zip: Phone: Cathedral City California 92234 (760) 324-0550 Responsible Building Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • 1 certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts I and 6 of the California Code of Regulations. • The building design features identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name: Signature: Tim Esser Tim Esser Company: Date: Esser Air Conditining 4/4/2014 Address: License: 36665 bankside Dr,Drive OFC,OFFICE 489046 City/State/Zip: Phone: Cathedral City California 92234 (760) 324-0550 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300. Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS Provider: CBPCA August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations (Page 1 of 5 Project Name: Climate Zone # # of Stories Steve Zell 2 15 1 General Information Site Address: 50970 Mango La Quinta CA 92235 Enforcement Agency: La Quinta, Cityof Date: 4/4/2014 Building Type ❑p Single Family ❑ Multi Family Circle the Front Orientation: (1), E, S, W, or degrees Conditioned Floor Area (CFA): 1500 Project Type: [Z]Alterations []Envelope F ❑ enestration ❑Roof HVAC Assemb • . ase EE Replacement or Change Out ElDuct Replacement ❑ Water Heater NOTE: This form is not to be used for Newly Constructed Buildings or Additions Insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below) Assembly Alteration ❑ Opening of framed cavity alone -Alterations that involve the opening of the framed cavity ofa wall, ceiling, or floor must install the mandatory minimum insulation value per §150 for the altered assembly. Fill in Columns A -C and enter mandatory insulation value in Column H. ❑ Replacement of entire assembly- Replacement of an entire wall, ceiling, or floor assembly requires the installation of Component Package- D insulation values in Table 151-C. Fill in Columns A - J. Opaque Surface Details For the furred portioned of Mass Walls see Furring Strips Construction Table below. A B I C D E F G I H I I J ProPosed See Note Standard Values From JA4 Table Tag/ Assemb • . ase EE t Framing Thickness* i "al c ng ( ` Framed Continuous ro J 4 ^ab' asknE'RR JA4 Proposed Assembly Assembly ID or T d`S 'ieq r 'ter' "Ffa or um ` aU CellValue$ U -factory "- T H o L a y Assembly :Dc c • H = o e > Final MassName or JA4 Table 2 Note: For furred asseinblies, accounting for Continuous7nsuTntion R -value; see Page JA4-3 and IVr—JoJa'For ialculating furred walls use the Mass and Furring Construction fable below:'° 1. For Tag/ID indicatiMe identii icati_on name that matchh the building plans'. ` 2. Indicate the Assembly Name or type: Ro f/Ceth g;.6{!alls, Floors,. Slabs, -yawl Space, oors c Indica!" the Size: SC e a lame'. and For Wood, Metal, Metal Buildings, Mass, enter. 2x.'4,/m2x6, or etc.- see JA4 for otherssible frame, rp ssembhesl " 3. Enter the thickness for in inches Spacrng mass or between framing members enter; -*or!d-'OL'; or/ Other"for all other o sembly description such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel -i' and etc.... 4. Based on the Climate Zone; enter the Standard U factor from, Table. 1151-B, C or D for each d ierent assembly Name"or type. S. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0 ". 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0 ". 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J 9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply. Furring Strips Construction Table for Mass Walls Onl -7—D -T A B C C-7—D—E F I G I H I J I K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Joint Appendix Table 4.3.5, 4.3.6 4.3.7 Joint Appendix Table 4.3.13 "- T H o L a y Assembly :Dc c • H = o e > Final MassName or JA4 Table 2 y " Eo c :3-,iiAssembl ' Thickness' Type' Numbed ¢ > c x c ¢ j ' U -factor' Comment Registration Number: 314-AO019857A-000000000-0000 Registration Date/Time: 04/04/2014 12:10:24 HERS Provider: CBPCA 2008 Residential Compliance Forms August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 2 of 5 Project Name: Climate Zone # # of Stories Steve Zell 2 115 1 Mass and Furring Strips Construction(footnotes) 1. Indicate the type of assembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can be found Reference Joint Appendix JA4. 2. This is the U -Factor based on the thickness of the assembly in inches. 3. The R -value of the insulation to be added on the interior or exterior of the assembly. 4. The Calculated R- Value is the R -value of the fared out section of the assembly. -6. The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix JA4. The equation is the inverse of Column D added to Column 1. Column K is the inverse from column J. 7. Insert the calculated U- actor value on to the Opaque Sur ace Details in Column J FENESTRATION PROPOSED AREAS ❑ Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. The Total Fenestration and West facing Area requirements are not applicable. _❑ Adding SO42 or less of window area —Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. ❑ Adding more than 50ft2 of window area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration Area requirements of Component Package D in Table 151-C Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -IR -ALT Orientation r. Fenestrationant°ra a +-1 (11%seld?\re' Itm„ui NFRC or Default indow, Glass.DoorovS li ht ., ,.South, Weft 40 ,fl ,U-factor2-3 MR;Values f . Yi t 1. Fenestration area is the area of total glaied product'"( e. glass plus frame). Exceph -, When dWd6r`tis less than -50% gldss, the fenestration area may be the glass area plus a "2 inch frame tareu nd the+glass a y es' 2. Enter value from Component Package D Requirements m Table 1515C. 3. Actual fenestration products installed and as indicated in CF 6R -ENV Form shall be equivalent to or have a flower_Ufactor and/or a lower SHGC value than that specified on the CF -IR ALT Form. _:--- - 4. Submit a completed WS -31? Form if a reduced SHGC is calculated with exterior shading. 5.Ifapplicable at this stage enter "NFRC" or NFRC Certified windows or are CEC "De ault " valuesfound in Table 116-A or B. ALTERED FENESTRATION -ALLOWED AREAS eeomp[eteifmoreiGan 50jtz'offenestration is'added)- --- A B C D E F G Allowed Existing Fenestration Total Area CFA of Entire % of Fenestration Area Fenestration Allowed Proposed Areal Dwelling CFA Area Removed Area Added A x B) (E -D) + C Total Fenestration Area (ft) .20 > West Fenestration Area (Required In .05 > CZ's 2,4&7-15 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12. 2. West facing glazing area removed cannot be "counted" twice. " In order to distribute the west glazing area removed to the other orientations, input the west glazing area removed in the Total Fenestration Area row, column D. 3. Include the Proposed Area of the West facing fenestration in both Area columns below. 4. To meet compliance, the ProposedArea must be less than orequal to the Total Allowed Area or BOTH the Total and West Fenestration Areas. Registration Number: 314-AO019857A-000000000-0000 Registration Date/Time: 04/04/2014 12:10:24 HERS Provider: CBPCA 2008 Residential Compliance Forms August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations age 3 of 5 Project Name: Climate Zone # # of Stories Steve Zell 2 15 1 ROOFING PRODUCTS (COOL ROOFS) §1511912 When the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1,000 ft2, whichever is less, the new roofing area musl meet the roofing product "Cool Roof" requirements of §152(b)1Hi, 152(b)IHii, or 152(b)1HiiL Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in §118(1) are not applicable. Do not fill table below. ❑ Cool Roofs Not Required in Climate Zones 1-12,14, and 16 with a Low Sloped. Less or 2:12 pitch. ❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less than 51blW. Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12) ❑ Insulation with a thermal resistance of at least 0.85 hril2•°F/Btu or at least a 3/4 inch air -space is added to the roof deck over an attic; or ❑ Existing ducts in the attic are insulated and sealed according to § 151(f)10; or ❑ In climate zones 10, 12 and 13, with 1 if of free ventilation area of attic ventilation for every 150 fig of attic floor area, and where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or ❑ Building has at least R-30 ceiling insulation; or ❑ Building has radian%t b ef ' the attic rrr ee++tiyyng a quir en of §151(t)2Perf&%rmance ❑ Building has no dAuc U r ni a U ❑ In climate zones 10 11,.13 and 147 R-3 or greater deck insulation alio a vented attic. Exception to §152(b)1Hui, Low -slope roof (i"pitch Z 10 n t ra ct o r Association ❑ Building has no ducts m the attic. , .. Other Exceptions l *. ❑ Roofing area covered by building integrated, photovoltaic panels and solar thermal pAnels. excmppt from the below Cool Roof criteria. ❑ Roof constructions that have thermal mass'over;the roof membrane with at least 25 IR/if is exem om the below Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, Check the applicable box below if Exem t from the Roofing Products "Cool Roo f"Re uirement:arm Roof Slope Product Weight * II' r"odu" ?ASed Solar Thermal CRRC Product ID Number < 2:12 > 2:12 > < 5lb/ft2 51blW-' Ty eZ; }w - Reflectance3'4 Emittance SRIS ❑ 1 ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.org/products/searciL 2. Indicate the type ofproduct is being used for the roof top, i.e. single ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(pini,iot - 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance. 4. Check box ifthe Aged Reflectance is a calculated value using the equation above. .Calculate the SRI value by using the SRI- Worksheet at hitp:/Avww.energyca.Qov/title24/and enter the resulting value in the SRI Column above and attach acopy of the SRI- Worksheet to the CF -JR. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §i 18(i)4. Select the applicable coating: 11Aluminum-PigmentedAsphalt Roof Coating TO Cement-BasedRoof Coating To Other Registration Number: 314-A0019857A-000000000-0000 Registration Date/Time: 04/04/2014 12:10:24 HERSProvider: CBPCA 2008 Residential Compliance Form, August 2009 —Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 4 of 5 Project Name: Climate Zone # # of Stories Steve Zell 2 15 1 HVAC SYSTEMS - HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydrorii ,space heating. Individual dwelling DHW heaters must be gas or propane fired, and may not exceed SO gallons. Hot water pipe insulation from the. DHW heater to the kitchen(s) and on all underground hot water pipes is required in all mponent packages in all climate zones. Water Heater Type/Fuel Minimum Duct or Piping Configuration Heating Equipment Efficiency Distribution Insulation Thermostat (Central, Split, Type and Capacity' 2,3 (AFUE or HSPF) Type and Location° R -Value T pe Space, Package or Hydronic Fumace, AFUE Ducted, SetBack Split System Capacity (gal) 1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc) 2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity < 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception. 3. Refer to the HERS Verification section on Page 4 of the CF -I R -ALT Form for additional requirements and check applicable boxes. 4. Indicate Type or Location (Ducts, Hydronic in Floor, Radiators, etc) HVAC SYSTEMS - COOLING Minimum Efficiency Duct or Piping Configuration Cooling Equipment (SEER/EER or Distribution Insulation Thermostat (Central, Split, Type and Ca acity',2 COP) Type and Location; R -Value Type Space, Package or H dronic AirConditioner,, R ! p,. SEER-, s D cted,_ . SetBack Split r a r I. Indicate Cooling Type, (NQHeat pump„ Evap•Cooling, etc , + ss 2. Refer to the HERS Verificattoti ection on Pag 4 o, ! R LST ' m r dit 1 re it tints chi ek t1t a ,oxes. 3. Indicate Type or Location(Ducts, H drontc ►n'Floor, Radiators, etc. IMN1.7 "WNW, WATER HEATINGVW low List water heaters and boilers for both domestic hot water (DHW) heaters and hydrorii ,space heating. Individual dwelling DHW heaters must be gas or propane fired, and may not exceed SO gallons. Hot water pipe insulation from the. DHW heater to the kitchen(s) and on all underground hot water pipes is required in all mponent packages in all climate zones. Water Heater Type/Fuel Distribution Type Number In Tank Energy Factor or External Tank Insulation Type' (Standard, Recirculating)Z System Capacity (gal) Thermal Efficiency R-Value3 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do not allow the installation of a recirculating water heating system for single dwelling units. 3. The external water heating tank and i es shall be insulated to meet the requirements o 150 ' . SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These items may require writlen 'usli icalion and documentation and special verification. NEW ROOF ASSEKBLLY - Radiant Barrier The radiant barrier requirement of §151(f)2 does not apply to roof alterations. Slab Edge (Perimeter) insulation 0 YES ONO YES: In Climate Zone 16 in Component Packages D, R-7 insulation is required. Heated Slab Insulation E3 YES ONO YES: Slab ed a insulation required for all heated slabs in all Climate Zones. See details in Table 118-A of the standards. Raised Slab Insulation Ll YES ONO YES: In Climate Zones 1, 2, 11, 13, 14 & 16, R-8 insulation is required; in Climate Zones 12 & 15, R-4 is required under component Package D. Thermal Mass - — - - - -- - -- — _ - -- — — To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach. Registration Number: 314-A0019857A-000000000-0000 Registration Date/Time: 04/04/2014 12:10:24 HERS Provider: CBPCA 2008 Residential Compliance Forms August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 5 of 5 Project Name: Climate Zone # # of Stories Steve Zell 2 15 1 HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final inspection. Duct Sealing & Testing HERS verification is required for this measure. 13 YES ❑ NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned space, the ducts are to be sealed per §152(b)1Dii and the newly installed ducts are to be insulated per §151(f)10. ❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos. ❑ YES 0 NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the ducts are to be sealed per §I52(b)IDi. El YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a.split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be sealed per § 152(b)1 E. 17 EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. ❑ EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. Refrigerant Charge -Split System HERS verification is requiredfor this measure. 0 YES 0 NO YES: InClimate Zones,2 and 8-15, whert,the existing HV equipment is replaced (including the replacement of the air I an•d e40411rdo r ac Iden ti it as' tt ; } tem A40or lit Uumm co"5I oro heatm' g coil, or the furnace heat iYJ`s wwu W • a Y a WR exchanger) a refri erant charge measurement shall be verified r t52(b)1 F. Central Fan Integrated (CFI) Ventilation4System"w n0d7 " a lFra" w AS S 0 C i a x i o n The ventilation reuirements of §150(o) do'not apply to existing residential homes. Ducted Split Systems : Air Conditioners and Heat Pumps- Airflow HERS,verifrca'tion>is required for this measure. 0 YES 0 NO YES: In Climate Zones 10 through 15, when the existing space c9nditioning system (HVAC equipment and ducting) is replaced, the airflow and fan watt draw shall be verified per 152(b)l Ci to"meet the requirements of § 151(f)7B. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and'com lete. Name: Tim Esser Signature: Tim Esser Company: Esser Air Conditining Date: 4/4/2014 Address: 36665 bankside Dr,Drive OFC,OFFICE If Applicable OCEA or 13CEPE (Certification.#): City/State/Zip: Cathedral City California92234 Phone: (760) 324-0550 Responsible Building Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements arts of Title 24, P 1 and 6 of the Califomia Code of Regulations. • The building design features identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with thisbuilding ermit application. Name: Tim Esser Signature: Tim Esser Company: Date: Esser Air Conditining 4/4/2014 Address: 36665 bankside Dr,Drive OFC,OFFICE License: 489046 City/State/Zip: Cathedral City California92234 Phone: (760) 324-0550 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300. Registration Number: 314-AO019857A-000000000-0000 Registration Date/Time: 04/04/2014 12:10:24 HERS Provider: CBPCA 2008 Residential Compliance Forms August 2009