Loading...
BELC2014-103178015 Main St Ste 109 BELC2014-1031 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4tit 4 4.Quixt COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BELC2014-1031 Property Address: 78015 MAIN ST 109 APW 770121007 Application Description: (12) CIRCUITS FOR APPLIANCES AND RECEPTACLES Property Zoning: Application Valuation: $4,000.00 Applicant: a HEGGE ELECTRICAL CONTRCTRS INC 0 OUTSIDE CITY LIMITS o 2014 LA QUINTA, CA 92253 SF MIWA 0V ,1W LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: :LIC -0000218 Date: r°C ` Contractor' J OWNER-BUILDE/DLARATION I hereby affirm under penalty of perjury thatempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the.provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/30/2014 Owner: BUILDING A LQ 6 ASHDOWN PL HALF MOON BAY, CA 92253 Contractor: HEGGE ELECTRICAL CONTRCTRS INC 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 (760)775-4860 Uc. No.::LIC-0000218 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. I ( Date: / v V Applicant:' I WARNING: FAILURE TO SECURE WORKERS' CO PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned property for inspection purposes: wJ -/ Date: 0 f Signature (Applicant or Agent): { FINANCIALINFORMATION /• DESCRIPTION - 'ACCOUNT -AMOUNT . AMOUNT :: PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY " METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID .4 PAID DATE DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 -:" PAID BY : METHOD RECEIPT # _. CHECK # CLTD BY DESCRIPTION ACCOUNT :, QTY" AMOUNT PAID PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY : METHOD RECEIPT #- - CHECK # CLTD BY Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ACCOUNT,'. . QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD ` RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 Description: (12) CIRCUITS FOR APPLIANCES AND RECEPTACLES Type: ELECTRICAL Subtype: Status: APPROVED Applied: 9/29/2014 AOR Approved: 9/29/2014 AOR Parcel No: 770121007 Site Address: 78015 MAIN ST 109 LA QUINTA,CA 92253 Subdivision: PM 30850 Block: Lot: 1 Issued: Lot Sq Ft:.O Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: (12) CIRCUITS FOR REVISED AND NEW APPLIANCES AND CONVENIENCE RECEPTACLES. THIS PERMIT DOES NOT INCLUDE APPROVAL OF CABINETRY, ACCESSIBILITY REQUIREMENTS, OR BUILDING OCCUPANCY. 2013 CALIFORNIA ELECTRICAL CODE. Apphea to Approvea Printed: Tuesday, September 30, 2014 12:53:34 PM 1 of 2 CHRON OLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES TELEPHONE CALL AJ ORTEGA 9/29/2014 9/29/2014 LEFT VOICE MESSAGE AT HEGGE ELECTRICAL THAT PLAN IS APPROVED'AND PERMIT IS READY TO ISSUE. CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT HEGGE ELECTRICAL CONTRCTRS INC 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 CONTRACTOR HEGGE ELECTRICAL CONTRCTRS INC 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 OWNER BUILDING A L Q 6 ASHDOWN PL HALF MOON CA 92253 BAY Printed: Tuesday, September 30, 2014 12:53:34 PM 1 of 2 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ` PAID BY . . CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 DEVICES, FIRST 20 101-0000-42403 0 $24.17 $0.00 DEVICES, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:i0 INSPECTIONS SEQID INSPECTION TYPE :. INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES ELECTRICAL FINAL" ATTACH M E,...... NTS Printed: Tuesday, September 30, 2014 12:53:34 PM 2 of 2 Bin`4. w31 10. City ofLa Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # G300 Project Address: Owner's Name:Alay-iAWe Address: 78 -/W /Way C A. P. Number: Np&4 Sy log Legal Description: ~ City, ST, Zip: 4 t '✓ y► , Contractor: VieTelephone:(MIA, 1114A ............ Address: 3 .. 'a Project Description: City, ST, Zip: ; 0 to VL Cie C_ Telephone:? V _ s::i;:.;;:#:>.:<;:::>;::>;<;s>;.<::f=s: ::s>rJUCWT State Lic. # : -7c/q/11 City Lic. #; Arch., Engr., Designer: Address: City., ST, Zip: Telephone: P = ::.4.:.:.:.:: :j ::.,Y,• ifCi ^: iii?i>LjjY: Construction Type: Occupancy: State Lic. #. ::'ij `i::.: (: .jj: i:•:: iiiyii;::;(;! JwBY'4ii: vi Jii 'r•:.S::f: J. s>>?; ' Project type (circle one): New Add'n Alter Repair Demo Name of Contact Pers -.. Sq. F[.: #Stories: #! Units: Telephone # of Contact Person: — Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Decd Plans picked up S.M.I. If-O.A. Approval Plans resubmitted Grading IN IIOUSE:- '`" Review, ready for correction ssu Developer Impact Fee Planning Approval Called Contact Person g A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees i ELECTRICAL N OTES I 10 THE FOOD SERVICE ELECTRICAL PLANS ARE PROVIDED, FOR THE SOLE LOCA ON MOUNDING PURPOSE OF INDICATING THE LOCATION OF ROUGH—INS, OUTLEtS, AND 1 TYPES OF CONNECTIONS FOR EQUIPMENT AND ELECTRICAL "LOADS. i OALL EQUIPMENT OUTLETS AND CONNECTIONS SHOWN ON THESE. PLANS ARE FOR FIXTURES AND EQUIPMENT SUPPLIED BY THE FOOD SERVICE CONTRACTOR (F.S.C.) EQUIPMENT NOTED AS "NOT INCLUDED. FLUSH IN CONTRACT" ON FOOD SERVICE EQUIPMENT SCHEDULE MUST BE VERfFIED' BY ELECTRICAL CONTRACTOR. SEE ARCHITECTURAL PLANS AND/OR GENERAL CONTRACTOR FOR FURTHER BUILDING ELECTRICAL REQUIREMENTS. OELECTRICAL CONTRACTOR SHALL CAREFULLY EXAMINE ALL FOOD SERVICE EQUIPMENT PLANS AND SPECIFICATIONS TO FULLY UNDERSTAND THE SCOPE OF WORK. ANY DISCREPANCIES ON THE PLANS OR SPECIFICATIONS SHALL BE RESOLVED PRIOR TO COMMENCING WORK. 40 ALL WORK SHOWN ON FOOD SERVICE ELECTRICAL PLANS AND AS OUTLINED IN THESE NOTES SHALL BE PERFORMED BY ELECTRICAL,'CONTRACT9R'UNDER. GENERAL CONTRACT. IT SHALL BE THE RESPONSIBILITY OF THE" ELECTRICAL ` CONTRACTOR TO SEE THAT HIS PHASE OF WORK IS INSTALLED IN ACCORDANCE WITH LOAD (WATTS) THE STANDARDS REQUIRED BY ALL LOCAL, STATE, AND FEDERAL LAWS, INCLUDING i HEALTH AND FIRE CODES, AND ANY AND ALL CODES PECULIAR TO THE MUNICIPALITY IN WHICH THE JOB IS BEING INSTALLED. i 50 ELECTRICAL CONNECTIONS, WIRING, AND HOOK—UPS OF EQUIPMENT AND FIXTURES SRKR INDICATED ON THESE PLANS ARE NOT PART OF F.S.C. CONTRACT AND SHALL BE REC!M DONE BY ELECTRICAL CONTRACTOR. LOAD (WATTS) 60 ELECTRICAL CONTRACTOR SHALL BE RESPONBLE, FOR - ALL PERMITS,, AND COMPLIANCE WITH ANY AND ALL RELATED CODES, INCLUDING ANY REQUIRED INSPECTIONS OF FIXTURES DURING OR AFTER FABRICATION. 70 ELECTRICAL CONTRACTOR SHALL CONNECT ALL EQUIPMENT AND FIXTURES AND DO .,ANY EXTERNAL WIRING TO FIXTURE TO MAKE EQUIPMENT FULLY OPERATIONAL. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT OR CORDS LONG ENOUGH TO ALLOW MOVEMENT OF EQUIPMENT FOR SERVICE. I, O ELECTRICAL CONTRACTOR SHALL SIZE ALL ELECTRICAL JUNCTION BOXES AND CONDUIT. ELECTRICAL CONTRACTOR SHALL PROVIDE AND LOCATE ALL JUNCTION BOXES, CONVENIENCE OUTLETS AND SWITCHES WHERE NOT PART OF FIXTURE, UNLESS OTHERWISE NOTED. EXTERNAL WIRING FOR SUCH ITEMS SHALL BE SUPPLIED AND OUTLETS F INSTALLED BY ELECTRICAL CONTRACTOR. WHEREVER ACCESS IS NOT AVAILABLE I' THE ELECTRICAL CONTRACTOR TO RUN HIS LINES FROM JUNCTION BOXES iFOR TO USAGE ON A. FIXTURE, THE FIXTURE FABRICATOR SHALL SUPPLY' AND INSTALL ' i SUITABLE CONDUIT FOR THE RUNNING OF SUCH LINES. ELECTRICAL CONTRACTOR 'e! SHALL PROVIDE EXTENSION SHIELDS, IF REQUIRED. ALL JUNCTION BOXES AND Z 2011 CONVENIENCE OUTLETS IN WALL SHALL BE INSTALLED FLUSH WITH FINSHED WALL i UNLESS OTHERWISE NOTED. ' OTHE SYMBOLS ON THE FOOD SERVICE ELECTRICAL PLAN ARE TO INDICATE LOCATfON AND TYPE OF CONNECTION ONLY. ELECTRICAL CONTRACTOR SHALL PROVIDE OUTLETS CIRCUITS AND CONDUIT RUNS AS REQUIRED. 540 10. ALL SYMBOLS FOR OUTLETS ON WALLS ARE INDICATED AT A SPECIFIC HEIGHT. HEIGHT OF OUTLET IS GIVEN FROM FINISHED FLOOR TO CENTER LINE OF T I OUTLET. ALL OUTLETS SHALL BE HORIZONTALLY MOUNTED. 3 11. ALL HORIZONTAL DIMENSIONS ARE FROM FACE OF FINISHED WALL TO CENTER 4 LINE OF OUTLET, OR FROM CENTER LINE OF OUTLET TO CENTER LINE OF OUTLET IN HORIZONTAL POSITION,. UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR, SHALL SUPPLY STAINLESS STEEL COVER PLATES FOR ALL SLIGHTS EXPOSED OR PARTIALLY.EXPOSED PULL BOXES _AND/OR ACCESS BOXES. . _.._._._ OFI OUTLETS 13. ELECTRICAL CONTRACTOR ..SHALL PROVIDE CAPS AND CORDS NOT PROVIDED BY THE MANUFACTURER, AND,,SHORTEN 'CORDS IF NECESSARY. 14. ELECTRICAL CONTRACTOR SHALL PROVIDE .AND INSTALL, AND DETERMINE I, WHERE OR WHEN TO PROVIDE, NECESSARY MAGNETIC STARTERS. 8 15. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECT SWITCHES TO ALL 6 EQUIPMENT AS REQUIRED PER CODE. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL SWITCHES FOR HEAT LAMPS, HOOD LIGHTS, AND MAKE—UP AIR AND EXHAUST SYSTEM. 50 0 ' 17. ELECTRICAL CONTRACTOR SHALL NOTIFY F.S.C. AFTER ROUGHING—IN OF GROUND INSTA HOT WORK AND STUB—OUTS FOR ' VERIFICATION OF PROPER LOCATION BEFORE COMPLETION OF WORK AND CLOSING OF WALLS OR FLOORS. r 18• ELECTRICAL CONTRACTOR SHALL VERIFY JOBSITE VOLTAGE. ELECTRICAL CONTRACTOR SHALL INSTALL VAPOR—PROOF LIGHTS IN WALK—IN 7 BOXES AND EXHAUST HOODS UNLESS OTHERWISE NOTED. LIGHTS SHALL BE 8 FURNISHED BY F.S.C. 1 20. ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO AND CONNECT ALL REMOTE ' CONDENSING UNITS, AND AUTOMATIC DEFROST SYSTEMS, IF APPLICABLE, AS ' LISTED IN THE FOOD SERVICE EQUIPMENT SCHEDULE.. TIME CLOCK AT INSTA HOT CONDENSING UNIT IS PART OF DEFROST SYSTEM AND SHALL BE INSTALLED BY 1200 ELECTRICAL CONTRACTOR. TIME CLOCK SHALL BE PROVIDED BY F.S.C. OR REFRIGERATION CONTRACTOR. MAGNETIC STARTERS AND THERMO—OVERLOAD I, PROTECTION SHALL ALSO BE PROVIDED BY ELECTRICAL CONTRACTOR. 9 21. WHERE LOCAL CODES OR CONDITIONS, SUCH AS WEATHER, CAUSE RELOCATION 10 OF REMOTE CONDENSING UNITS OTHER THAN AS DESIGNATED ON THE FOOD SERVICE PLANS, PLEASE CONTACT F.S.C. IMMEDIATELY. CONDENSING UNIT RACK AND HOUSING MUST BE APPROVED BY REFRIGERATION CONTRACTOR. j 22. ELECTRICAL CONTRACTOR SHALL, PROVIDE AND INSTALL, AND .PROVIDE ELEC— i TRICAL CONNECTION FOR ELECTRICAL HEATING TAPE FOR WALK—IN FREEZER `} : CONDENSATE' UNE FROM COIL TO WASTE. 23. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL 4" APPROVED CONDUIT 11 FOR REFRIGERATION LINES. 12 24. WHERE NOTED, ELECTRICIAN SHALL PROVIDE AND INSTALL APPROVED CONDUIT g (SIZE AS NOTED) -FOR SYRUP LINES IN FLOOR OR CEILING (AS NOTED), WITH MIN. ,!r 24" RADIUS BEND. STUB UP 6" ABOVE FINISHED FLOOR (A.F.F.). 25. WHERE NOTED, ELECTRICIAN SHALL PROVIDE AND INSTALL APPROVED. CONDUIT FLOOR OUTLETS (SIZE AS NOTED) FOR BEER LINES IN FLOOR OR CEILING NOTED, 'WITH MIN. ,(AS 24" RADIUS BEND. STUB UP 6" A.F.F. 26. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL DOOR ACTIVATED SWITCHES FOR ALL AIR CURTAINS AND FLY FANS LISTED ON FOOD SERVICE PLANS. 13 a 27. ELECTRICAL CONTRACTOR SHALL PROVIDE POWER ON ROOF FOR, AND CON— 14 NECT EXHAUST AND MAKE—UP AIR FANS, AND PROVIDE WATERPROOF ` DISCONNECT SWITCHES. SWITCHES SHALL BE LOCATED WHERE SHOWN ON F.S.C. PLANS OR AS DIRECTED BY VENTILATION CONTRACTOR. EXHAUST AND MAKE-UP AIR FANS SHALL BE INTERCONNECTED TO OPERATE BY ONE SWITCH—SWAMP OUTLETS COOLER PUMP SHALL BE PROVIDED WITH SEPARATE SWITCH. 900 28. IF ELECTRICAL EQUIPMENT IS SUPPLIED UNDER EXHAUST HOOD, HOOD FIRE SUPPRESSION SYSTEM SHALL BE SUPPLIED WITH MICRO—SWITCH. ELECTRICAL CONTRACTOR SHALL WIRE ELECTRICAL SHUT DOWNS TO FIRE SUPPRESSION 15 j SYSTEM. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT IN WALL FOR 16 HOOD FIRE PROTECTION SYSTEM. VERIFY LOCATION WITH F.S.C. 29. ELECTRICAL CONTRACTOR SHALL PROVIDE AN AUTOMATIC MEANS TO ENSURE THE SHUT OFF OF POWER TO ALL APPLIANCES AND/OR OUTLETS LOCATED I UNDER VENTILATING EQUIPMENT UPON ACTUATION OF THE FIRE SUPPRESSION FI_oOR OUTLETS SYSTEM VIA A MICRO—SWITCH SUPPLED BY FIRE SUPPRESSION CONTRACTOR. IF THE MAKE—UP AIR IS AN INTEGRAL PART OF THE HOOD, IT MUST BE SHUT n D OWN UPON ACTUATION OF THE FIRE SUPPRESSION SYSTEM (NEPA 17A). DO NOT SHUT OFF EXHAUST FAN! I 30. ALL 120 VOLT OUTLETS SHALL BE GFI TYPE. 18 31. SEE HOOD FIRE PROTECTION SYSTEM NOTES -IT LEGEND = ELECTRICAL CONNECTIONS DUPLEX RECEPT., 20 -AMP, 120—VOLT, GROUND TYPE ® SPECIAL PURPOSE OUTLET, 120—VOLT,, GROUND TYPE ® SPECIAL PURPOSE OUTLET, 208/240—VOLT AS INnI(.'ATFD. GROUND TYPE MAIN: LUGS ONLY i E Ste: 109 I LOCA ON MOUNDING 1st Floor -- i FLUSH BUS: 125 AMPS--1120/208VO1~T 3-PHASE4WIRE LOCATION LOAD (WATTS) LTS REC MISC BRKR CRKT CRKT SRKR LTS REC!M ISC LOAD (WATTS) OUTLETS F 900 2011 1 Z 2011 i 1 650 - _ LIGHTS OUTLETS 540 2011 3 4 20/1 j050 SLIGHTS _.._._._ OFI OUTLETS -_—y"--- 540 ` 2011 8 6 2017 £ 50 0 ' LIGHTS INSTA HOT 1200 I 20/2 7 8 2011 800 { LIGHTS INSTA HOT 1200 7k 9 10 2012 A EMERGENCY LTS - -.._ .. ._ i 900 2011 11 12 " 4' L7111 FA FLOOR OUTLETS 540 2011 13 a 14 SOl3 2017 I 017 /C 4 AIC 4 OUTLETS 900 2011 15 j 16 _ FI_oOR OUTLETS v 540 { 2011 17 _i--- _ 18 I - s 2017 ___—r-_.. A/C 4 —` 0 Nava Design Group. 49132 VALLE POSADA COACHELLA CALIFORNIA 92236. Email, navadesigngroup0yohoo.com PHONE (760)777-3260 S"IMN. 1811 CITY 0171DA OUINTA BUILDING & SAFETY DEPT. ARPROVED FOR CONSTRUCTION DATE "1 1 101 SY- . 8 ee rNt. e► + 1 W U) Date Client Name Grand Vin Wine Bar 78015 MAIN STREET #109 LA QUINTA CA. 92253 Foodservice Electrical Plan Project number E000.38253645 Date SEPTEMBER 18, 201 Drawn by E. Na% Checked by U 3GE ELECTRICAL CONTRACTORS INC. LIC#748171 `HEGGE,=,CEO' FS - 4 Scale 1/4" =