Loading...
RC (08-0273)78075 Main St Ste 103 08-0273 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00000273 '..Property Address: 78075 MAIN(ST STE_ 103-_- APN: 770-121-011' - - Application description: ' REMODEL - COMMERCIAL Property Zoning: VILLAGE COMMERCIAL Application valuation: 7500 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B Lijceen seeNo.: 664238 VDate:S-Y) Contractor: UI/IJe 1 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance; also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicaht to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply.to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to'an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed - pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: S`ti Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lendei's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012' FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/05/08 Owner: MARVIN INVESTM NTS 78015 MAIN! 205 n LA QUINTA C [n LA QUINTA, 2253 MAR 0 6 2000 Contractor: WISE MAINTE CET (y - P . O . BOX 17 FINA E DtY I LA QUINTA, CA .92253 (760)5'64-0821 Lic. No.: 664238 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is . issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: - Carrier EXEMPT - Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should becoe subject to the workers' compensation provisions of Section (,,,, 3' 700 of the Labor Co, I shall ort with comply with those provisions. % . Date: !- -.-J v,yJ Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . -Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend,indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2: Any permit issued as a result of this application becomes null and void if'work is not commenced within 180 days from date of issuance of such permit, or.cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and stale laws relating to buildin construe on d hereby authorize"representatives of this con o enter upon the above-mentioned pr arty i t n,pu, oses. _ X Date: S (1 `3ignature (Applicant or Agent): Application Number . . . 08-00000273 ------ Structure Information 1,208SF TI/V-B/B-OCC/40-OL ----- Other struct info CODE EDITION 2007BEMPE FIRE SPRINKLERS FULLY MIXED-USE OCCUPANCY B OCCUPANT LOAD 40.00 1ST FLOOR SQUARE FOOTAGE ---------------------------------------------------------------------------- 1208.00 Permit . . . BUILDING PERMIT Additional desc .'. Permit Fee- 99.00 Plan Check Fee 64.35 Issue Date . . . . Valuation 7500 Expiration Date 9/01/08 Qty Unit Charge ;Per Extension BASE FEE 45.00 6.00% 9.0000 THOU BLDG 2,001-25,000 • ---------------------------------------------------------------------------- 54.00 Permit . . . ELECT _ ADD/ALT/REM Additional desc . Permit Fee- 39.90, Plan Check Fee 9.98 Issue Date . . . . Valuation . . - . 0 Expiration Date - 9/01/08 Qty Unit Charge Per Extension BASE FEE 15.00 •20.00 .7500 PER ELEC DEVICE/FIXTURE "1ST 20 15.00 22.00 .4500 EA ELEC DEVICE/FIXTURE >20 --------------- 9.90 Special Notes and Comments --------------- . 1;208SF TI [HOMEC JEWELRY]/V-B/B/40-OL. THIS PERMIT DOES NOT INCLUDE BLUILDING SIGNAGE, MECHANICAL OR PLUMBING. 2007, BUILDING, ENERGY CODES.. March 5, 2008 2:12:14 PM AORTEGA -'--------------------------------=------------------------------------------ Other Fees . . . . . ... . ACCESSIBILITY PLAN REVIEW 6.44 ENERGY REVIEW FEE 6.44 .Fee summary Charged- Paid, Credited Due Permit Fee Total 138.90 .00 .00 138.90 Plan Check Total 74.33 .00 .00 74.33 Other Fee Total 12.88 .00 .00 12.88 Grand Total 226.11 .-00. .00 226.11 LQPERAIIT Bin # City of La Quinta , Building & Safety Division ' P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 0$ ^ Project Address: ,41AI S STrr 6Ia3 Owner's Name: v/A/ A. P. Number: j.0 — 2 I — Q t Address: 7e-61.5* 44AM4 ST. S ZU $' Legal Description: _. Contractor: / . Address• City, ST, Zip: CA Telephone: '7 d'O 7 7/ ._ 2 S -d ] Project Description: City, ST, Zip: 71503VA 7_6A1A,,V,- PRdUC ^/T3' o . svil'E Telephone: G/! J 1✓F D E /GG E State Lic. # : City Lic. #: Arch., Engr., Designer: S a U TH W FST C o N GEPr S G'Q/N , /11i Address: 7t" 1s C LACE GST LSO SvITt 261 City, ST, Zip: ZA glultJrg C. Z S3 Telephone: ( G i 76 aSl y %d j, l 9 I x ! ri, _ Construction Type: Occupancy: YP State Lic. #:5-23,?37 G.C. Project type (circle one): New. Add'n Alter Repair Demo Name of Contact Person: P E^/ N E Sq. Ft.: 2 O 8 # Storie ', #Units:' Telephone # of Contact Person: 40 S'6S/-y 07 Estimated Value of Project: ' 5M to I APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING. PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for correctionsA 4 Plan Check Deposit Truss Calcs. Called Contact Person1141 Plan Check Balance Energy Calcs. Plans picked up 11 . Construction rd Flood plain plan Plans resubmitted 101 Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person . Plumbing Grant Deed Plans picked up - Q6 S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Review, ready for correction issue a/a' Developer Impact Fee ! Planning Approval Called Contac erson A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Eva 64.1014'. -a John R. Hawkins Fire Chief RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd., # 201 Palm Desert, CA 92211-413 • (760) 863-8886 • Fax (760) 863-7072 February 7, 2008 Proudly serving the Robert Andreasen unincorporated 53-740 Eisenhower areas of Riverside La Quinta, CA 92253 County and the Cities of: Banning Beaumont Calimesa Canyon Lake 4. Coachella .; Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta .; Moreno Valley Palm Desert Perris e. - Rancho Mirage Rubidoux CSD San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson; District 4 Marion Ashley, District 5 RE: TENANT IMPROVEMENT PLAN CHECK LAQ-08-TI-013- Homec Jewelry You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. THE FOLLOWING CONDITIONS MUST BE "MET PRIOR TO INSPECTION: Provide keys to the tenant space for inclusion in the main building, Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. Shelving, counters, etc., must be in place, however, no merchandise may be placed in the building prior to inspection A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed ,fire extinguisher company must service extinguisher yearly. ELECTRICAL PANEL BOX: All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. \ OTHER REQUIREMENTS: In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must' be legible and of a contrasting color with the background. and adequately illuminated to be visible from the street at all hours. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high. on a contrasting background. Applicant/installer shall.be responsible to contact the Fire Department to schedule inspections. A re -inspection fee will be required if more than one (1) inspection is necessary. 2300 Market St., #150 • Riverside, CA 92507 • (951) 955-4777 • Fax (951) 9.55-4886 39493 Los Alamos Rd., #A • Murrieta, CA 92563 • (951) 60.0-6160 • .Fax (951) 600-6164 Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. . By. G2ason Walsh Safety Specialist 2300 Market St., #150 Riverside, CA -92507. (951) 955-4777 • Fax (951) 955-4886 . 39493 Los Alamos Rd., #A • Murrieta, CA 92563 • (951) 600-6160 • Fax (951) 600-6164 i John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning Beaumont Calimesa Canyon Lake Coachella 4. Desert Hot Springs . Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert 4. Perris Rancho Mirage :- Rubidoux CSD 4. San Jacinto 4. Temecula Board of Supervisors Bob Buster, District l John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, - District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date Z q la La Quinta Building Department k RE We / r o , The Riversides County Fire Department is granting the fire clearance for the following location 7 0 — 41 %Jr /4j )' 1 S I. Please call if you should have questions. 760-863-8886. Thank You Respectfully, Jas Stubble Fire Safety Specialist Certificate of Occupancy MATM 9 Building &Safety Department s Certificate is issued pursuant to the requirements, of Section 109 of the California Building ale, certifying that, at the tine of issuance, this structure .was in compliance with the visions. of the Building Code and the various 'ordinances of the City regulating building istruction and/or use. BUILDING ADDRESS: i 8=Q75-MAM-ST #1-03 classification: COMMERCIAL (HOMEC JEWELERS) Building Permit No.: 08-273 ;upancy Group: B Type of Construction: V -B Total Square Footage: 1,208 Land Use Zone: CR ign Occupant Load: 40 Code Edition: 2007 CBC/CEC/CMC/CPC/07. Energy Codes Sprinkler System: YES ier of Building: MA VIN INVESTMENTS. Add 78 015 MAIN ST CONSPICUOUS PLACE # Building Official ress. 205 City, ST, ZIP: LA QUINTA, CA 92253 By: STEVE TRAXEL Date: March 28, 2008 TITLE 24 REPORT Title 24 Report for: Homec Jewelry Tenant Improvement 78-075 Main Street, Suite G103 La Quinta, Ca 92253 Project Designer: South West Concepts 78-115 Calle Estado, Suite 201 La Quinta, Ca 92253 (760) 564-4707 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: kU, TY OF LA QUINT,ILDING & SAFETY DEP APPROVED FOR CONSTRUCTION Date: on Y 2/25/2008 J he EnergyPro computer program has been used to perform the calculations summarized in this corn7This progra ce o:a:sapproval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. lt- EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTG -1-C Certificate of Compliance .3 Form LTG -2-C Indoor Lighting Schedule 7 Form LTG -3-C Portable Lighting Worksheet ' 8 Form LTG -4-C Lighting Controls Credit Worksheet 9 Form LTG -5-C Indoor Lighting Power Allowance 10 Form LTG -7-C Room Cavity Ratio -Worksheet 11 Form LTG -MM Lighting Mandatory Measures 12 S EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 4 4 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C ROJECT NAME DATE Homec Jewelry Tenant Improvement 2/25/2008 OJECT ADDRESS 78-075 Main Street, Suite G103 La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # South West Concepts (760) 564-4707 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 1 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 1,208 sq.Ft. 15 BUILDING TYPE LTJ NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION [X] NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING a AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is iccurate a d complete. DOCUMENTATION AUTHOR SIGNAT DATE . Tim Scott S-40 S The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146, 148 & 149 of Title 24, Part 6. /The plans & specifications meet the requirements of Part 6 (Sections 10-103a). --'rhe installation certificates meet the requirements of Part 6 (10-103a 3). ❑,The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # South West Concepts LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals MLTG-1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed ®LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed MLTG-2-C: Indoor Lighting Schedule ®LTG -3-C: Portable Lighting Worksheet ®LTG -4-C: Lighting Controls Credit Worksheet ® LTG -5-C: Indoor Lighting Power Allowance MLTG-6-C: Tailored Method Worksheet LTG -7-C: Room Cavity Ratio Worksheet LTG -8-C: Common Lighting Systems Method Worksheet ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:3 of 13 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1-C NAME DATE Homec Jewelry Tenant Im rovement 2/25/2008 .ED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 1 702 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG4-C) 56 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1,646 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ' ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1,812 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG --5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE Check if ;NOTE TO (Room #) IDENTIFICATION (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Daytighting FIELD n " G S C - ce-5 rLrL CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C] ROJECT NAME DATE Homec Jewelry Tenant Improvement -2/25/2008 :ONTROLS FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROLTYPE (Occupant, Daylight, Dimming, etc.) Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft Occ Sensor - <= 250 sqft LUMINAIRESCONTROLLED TYPE # OF LUMINAIRES A 4 D 1 G 1 `NOTE TO `FIELD F_ L i 4 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1-C PROJECT NAME Homec Jewelry Tenant Improvement DATE 2/25/2008 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated•for normal use; all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Descri tion Test Performed BY: ❑ LTG-2-A: Lighting Control.Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testingorC br_ ❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance. testing . I. • EnergyPro 4.4 by EnergySoft User Number: 6712 .. . I Job Number: Page:6 of 13 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C 4 ECT NAME DATE Homec Jewelry Tenant Improvement 2/25/2008 HTING POWER FOR Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type. Description .gym 3 U C0)C 3.33 y+ _. `D ` ° m 39! to co z C2LC 3.v3 m,y -.'O `, C 3v N - `D o dm q = z 503 d (D N vN (D n A F) 4 ft Fluorescent T8 Energy Savings F32T8 2 30 1.0 54.0 X 8 432 Can 6" Can light 1 26 1.0 28.0 X 7 196 D Portfolio #C6032' FM 26W/GX24 -2 2 26 2.0 26.0 X 1 26 G P1ec ft Fluorescent T8 Energy Savings 32T8 1 301 1.0 36.0 X 1 36 LV 42w Low Voltage Halogen Mag42 Watt Lamp 1 42 1.0 46.0 X 22 1,012 PAGE TOTAL 1 702 BUILDING TOTAL (sum of all pages) 1 ,702 PORTABLE LIGHTING (From LTG -3-C) O CONTROL CREDIT (From LTG -4-C) 56 • ADJUSTED ACTUAL WATTS 1 646 I EnergvPro 4.4 by EnergvSoft User Number: 6712 Job Number: Page:7 of 13 1 PORTABLE LIGHTING WORKSHEET LTG -3-C ROJECT NAME Homec Jewelry Tenant Improvement DATE 2/25/2008 A B TOTAL WATTS TABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 S!@ UARE FEET A B C D ROOM # OR ZONE ID DEFAULT W/s ft AREA SF TOTAL WATTS B X C Suite G103 1,208 1 1 208 TOTAL 0 0 ITABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET I A B TOTAL WATTS C D E F G ROOM # PORTABLE LIGHTING OR ZONE ID Description # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite G103 1,208 1 1 208 TOTAL 1,208 0 TABLE 3 - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID (SF) TOTALI 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types and mounting locations relative to work areas. EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 13 BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TOTAL 1,208 0 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 13 LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG -4-C CONTROL CREDITS FOR CONDITIONED SPACES OJECT NAME DATE Homec Jewelry Tenant Improvement 2/25/2008 A B C D E F G H I J ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR' CONTROL CREDIT WATTS (H X 1) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Suite G103 Occ Sensor sgft <-250 A 1,208 216 0.20 43 Suite G103 Occ Sensor - — 250scift p 1,208 26 0.20 5 Suite G103 Occ Sensor - — 250 sqft G 1,208 36 0.20 7 PAGE TOTAL 56 1) From Equation 146-A 2) From Table 146-A BUILDING TOTAL 56 Enter in LTG -2-C: Lighting Control Credit I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:9 of 13 1 INDOOR LIGHTING POWER ALLOWANCE LTG -5-C EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:10 of 13 I PROJECT NAME Homec Jewelry Tenant Improvement DATE 2/25/2008 LLOWED LIGHTING POWER Choose One Method COMPLETE BUILDING METHOD - CONDITIONED SPACES WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-B) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF Comp Bldg Retail and Wholesale 1.50 1,208 1,812 PAGE TOTAL _ .. BUILDING TOTAL 1,28 1,812 1 ,208 AREA 1 ,812 WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS (From LTG -6-C or from computer run.) O UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL D AREA D WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS D (From LTG -5-C and LTG -6-C) 0 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:10 of 13 I A EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: 11 of 13 Page: ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C .C.. PROJECT NAME Homec Jewelry Tenant Improvement FOR ENFORCEMENT AGENCY USE ONLY F CUMENTATION AUTHOR DATE 2/25/2008 PLAN CHECK BY DATE Room Perimeter (P) RECTANGULAR SPACES A B C D E F Room Name Task/Activity Description Room Length (L) (ft) Room Width (W) (ft) Room Cavity Height (H) (ft Room Cay. Ratio 5xHx(L+W) NON -RECTANGULAR SPACES A EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: 11 of 13 Page: B . .. .C.. ...p. E F Room Name Task/Activity Description Room Area (A) M(ft) Room Perimeter (P) ) /(LxW) A EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: 11 of 13 Page: B . .. .C.. ...p. E F Room Name Task/Activity Description Room Area (A) M(ft) Room Perimeter (P) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A 4 r L LIGHTING MANDATORY MEASURES LTG -MM NAMEHomecJewelry Tenant Improvement IoATE2/25/2008 DESCRIPTION Desi ner Enforcement 0 §131(d)l For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 0 §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed,by the manufacturer.. §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X❑ §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. 0 §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. 0 §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by.a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously.shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ❑ §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 13 1 F— L L LIGHTING INSPECTION CHECKLIST LTG-I ROJECT NAME Homec Jewelry Tenant Improvement INSPECTION DATE 2/25/2008 FIXTURE CODE TYPE DESCRIPTION LAMP TYPE LAMP QUANT. NUMBER OF FIXTURES WATTS PER FIXTURE FIELD NOTES A 2 4 ft Fluorescent T8 Energy Savings Elec F32T8 2 8 54.0 Can 6" Can light 1 7 28.0 D Portfolio #C6032 CFM 2 11 26.0 G 1 4 ft Fluorescent T8 Energy Savings Elec F32T8 1 1 36.0 LV. 42w Low Voltage Halogen Mag 42 Watt 1 22 46.0 Lamp I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:13 of 13 1 Bin 1 City of La t.- Quinta Building 4 Safety Division P.O: Boxi 1504, 78-495 Calle Tampico ' ' Permit # - La Quinta, CA.92253,- (760) 777-7012 bBuildingPermit Application and Tracking" Sheet Project Address:' 7 , G/D S' Owner's Name: s ;' •' - , A. P.-Number: % p ,_ Z „ Da / Address:", Y Legal Description: City, ST, Zip: A' Contractor: p Tele hone: Address: ,. • Project Description: ' c City, ST, Zip: Telephone:t 51 ON it G/ H 7-/A)(:;- - State Lic. # .City Li.e. / - ---- — Arch.; Engr., Designer:. ti Address: 8 /s C,@ C L C-5 A DO '57* 241 City, ST, Zip: : f,f,Z C//NTA C4 , r Telephone: ' Gy y7a Construction Type:L Gv s/vim Occupancy: ' State Lic. #: z ` Project type (circle one): New Add'n ` Alter 'Repair Demo, Name of Contact Person: S` Sq. Ft.: #Stories: E _ Telephone # of Contact Person: %Q. - Estimated Value of Project: ' A• I APPLICANT: DO NOT WRITE BELOW THIS LINE, # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted7/21VI Item , Amount Structural Calcs. Reviewed, ready for corrections * - 'Plan Check Deposit Truss Calcs. Called Contact Person / Plan Check Balance Energy Calcs. Zj Plans picked up : I Construction Flood plain plan Plans resubmitted z Mechanical Gradin lan' •a g p 2 Review, ready for corrections/issue Subcontactor ListCalled Contact Person[P= lumbing Grant Deed Plans picked up ' S H.O.A. Approval Plans resubmitted - Grading IN HOUSE:- ! ''d Review, ready for correction i sue ` Developer Impact Fee Planning Approval Called Contact Person , Pub. Wks. Appr Date of permit issue , School Fees f ' Total Permit Fees TITLE 24 REPORT Title 24 Report for: Homec Jewelry Tenant Improvement 78-075 Main Street, Suite G103 La Quinta, Ca 92253 Project Designer: South West Concepts 78-115 Calle Estado, Suite 201. La Quinta, Ca 92253 (760) 564-4707 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA BY A=- I Date: 3/14/2008 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is athorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTG -1-C Certificate of Compliance 3 Form LTG -2-C Indoor Lighting Schedule 7 Form LTG -3-C Portable Lighting Worksheet '8 Form LTG -4-C Lighting Controls Credit Worksheet 9 Form LTG -5-C Indoor Lighting Power Allowance 10 Form LTG -7-C Room Cavity Ratio Worksheet 11 Form LTG -MM Lighting Mandatory Measures 12 EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 r EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C ROJECT NAME DATE Homec Jewelry Tenant Improvement 3/14/2008_ OJECT ADDRESS 78-075 Main Street, Suite G103 La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit# South West Concepts (760) 564-4707 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 1,208 Sq.Ft. 15 BUILDING TYPE 0 NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING F--1COMPLETEBUILDING a AREA CATEGORY TAILORED F—] PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificatea plies only to building lighting requirements. The documentation preparer hereby certifies that the documentation7s accuratp and complete. DOCUMENTATION AUTHOR SIGNA DATE Tim Scott ,' DQE The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction d cum nts is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 146, 148 & 149 of Title 24, Part 6. L1132, *fhe plans & specifications meet the requirements of Part 6 (Sections 10-103a). 4he installation certificates meet the requirements of Part 6 (10-103a 3). El ,1 he operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑G`I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # South West Concepts LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals MLTG-1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed MLTG-1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed 19 LTG -2-C: Indoor Lighting Schedule IR LTG -3-C: Portable Lighting Worksheet MLTG-4-C: Lighting Controls Credit Worksheet M LTG -5-C: Indoor Lighting Power Allowance LTG -6-C: Tailored Method Worksheet LTG -7-C: Room Cavity Ratio Worksheet LTG -8-C: Common Lighting Systems Method Worksheet OLTG-9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:3 of 13 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C 19OJECT NAME DATE HomeC Jewelry Tenant Improvement 1 3/14/2008 INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) PORTABLE LIGHTING (From LTG -3-C) LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG4-C) UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED WATTS 1,848 0 50 1,798 0 0 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1 812 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE Check if NOTE TO`. (Room #) IDENTIFICATION (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Daylighting FIELD Ow c.1,L -?--0Tf4t I- s TZIL OK4!L ©L. LL - of -p L, CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C EDATE Homec Jewelry Tenant Improvement I 3/14/2008 CONTROL CONTROL TYPE NAI Wngp NOTE TO IDENTIFICATION (Occupant, Daylight, Dimming, etc.) TYPE RES FIELD Occ Sensor - — 250 sqft A 4 Occ Sensor - — 250 s ft G 1 I EneravPro 4.4 by EnerovSoft User Number: 6712 Job Number: Paae:5 of 13 1 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG-1-C PROJECT NAME Homec jewelry Tenant Improvement DATE 3/14/2008 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: O LTG-2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing `J v"S C°.u:)"L .F, Y Cc.GG OCA Si--N 9 O LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing I EnergyPro 4.4 by EnergySoft User Number: 6712 1 Job Number: Page:6 of 13 1 NDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C ROJECT Homec Jewelry Tenant Improvement LIGHTING POWER FOR CONDITIONED SPAC DATE 3/14/2008 Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description m -03 CD -0 cmc .33 +CD .- fD oriv 3 »' L N civg 3. .3 9 Q N. N m o`DYes c 3v D) N O dm c_ _ n No r c Z 'o` d 3 _ N rD N xdm — N CD a A 2) 4 ft Fluorescent T8 Energy Savings lec F32T8 2 30 1.0 54.0 X 1 81 432 Can 70w Recessedlncandescent 1 70 70.0 X 4 280 D (1)26WCan FM 26W/GX24 -2 2 26 - 2.0 26.0 X 1 26 E 6", Can light FTR26W/GX24 -3 1 26 1.0 28.0 X 3 84 Eye 45w Recessed Incandescent 1 45 45.0 X 2 90 G 4 ft Fluorescent T8 Energy Savings P) 36 LV 70w Low Voltage Halogen Mag 70 Watt LaMD 1' ""70 1.0 75:0 X1 12 900 PAGE TOTAL 1 848 BUILDING TOTAL (sum of all pages) PORTABLE LIGHTING (From LTG -3-C) O CONTROL CREDIT (From LTG -4-C) 50 • ADJUSTED ACTUAL WATTS 1 798 I EnergyPro 4.4 by EnergySoft User Number: 6712 • • Job Number: Page:7 of 13 1 PORTABLE LIGHTING WORKSHEET LTG -3-C ROJECT NAME Homec Jewelry Tenant Improvement DATE 3/14/2008 FEET I A TABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B C D ROOM # OR ZONE ID DEFAULT W/s ft AREA TOTAL WATTS SF B X C # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite G103 1,208 1 1,208 TOTAL 0 0 r L ITABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET I A B 0 C. D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. WATTS PER FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) Suite G103 1,208 1 1,208 TOTAL 1,208 0 TABLE 3 - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID (SF) TOTALI 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TOTAL 1,208 0 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 13 LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG -4-C CONTROL CREDITS FOR CONDITIONED SPACES OJECT NAME DATE Homec Jewelry Tenant Improvement 3/14/2008 A B C D E I F G H I J ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR' CONTROL CREDIT WATTS (H X I) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Suite G103 occ Sensor - 250 A 1 1,208 216 0.20 43 Suite G103 'Occ Sensor <-250 qft G 1 208 36 0.20 7 1) From Equation 146-A 2) From Table 146-A PAGE TOTAL 50 BUILDING TOTAL 50 Enter in LTG -2-C: Lighting Control Credit EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 13 1 4 4 i INDOOR LIGHTING POWER ALLOWANCE LTG -S -C OJECT NAME Homec Jewel Tenant Im rovement kL E 3/14/2008 LOWED LIGHTING POWER Choose One Method COMPLETE BUILDING METHOD - CONDITIONED SPACES ALLOWED WATTS WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-B) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF Comp Bldq Retail and Wholesale 1.50 1,208 1,812 PAGE TOTAL BUILDING TOTAL D D D AREA D WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) 0 D EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 13 PAGE TOTAL BUILDING TOTAL 1 ,208 1 ,812 1 ,208 AREA 1 ,812 WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS D (From LTG -6-C or from computer run.) UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL D D D AREA D WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) 0 D EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 13 BROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C PROJECT NAME Homec Jewelry Tenant Improvement NTATION AUTHOR PACES A Room Name DATE B C D Room Room Task/Activity Length (L) Width (W) Description (ft ft ENFORCEMENT AGENCY USE ONLY ICHECK BYDATE Height (H) F Room Cay. Ratio 5xHx(L+W) /(LxW) _IGHTING MANDATORY MEASURES LTG -MM ROJECT NAME DATE Homec JewelryTenant Improvement 3/14/2008 DESCRIPTION Designer Enforcement a §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X] §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X] §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified,.all alternate equipment shall be certified and installed as directed by the manufacturer. X] §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. 0 §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. X❑ §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 _ square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. - ❑ §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:12 of 13 LIGHTING INSPECTION CHECKLIST LTG -II NAME INSPECTION DATE Homec Jewelry Tenant Improvement 3/14/2008 FIXTURE CODE TYPE DESCRIPTION LAMP TYPE LAMP QUANT. NUMBER OF FIXTURES WATTS PER FIXTURE FIELD NOTES A 2 4 ft Fluorescent T8 Energy Savings Elec F32T8 2 8 54.0 Can 70w Recessed Incandescent 70W 1 4 70.0 D M26 W Can CFM 2 1 26.0 E 6" Can light 11 3 28.0 Eye 45w Recessed Incandescent 45W 1 2 45.0 . G 1 4 ft Fluorescent T8 Energy Savings Elec F32T8 1 1 36.0 LV 70w Low Voltage Halogen Mag 70 Watt 1 12 75.0 Lamp EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 13 of 13