Loading...
RC (11-1127)78100 Main St Ste 101 11-1127 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT r Application Number: 1-1-06001127 Owner: Property Address: 78100 MAIN ST STE-. 101 OLD TOWN LA QUINTA APN: 770-1217010- - - 78015 MAIN ST #205 Application description: REMODEL - COMMERCIAL LA QUINTA CA Property Zoning: VILLAGE COMMERCIAL LA QUINTA, CA 92253 Application valuation: 1000 Contractor: Applicant: Architect or Engineer: MARVIN INVESTMENTS, INC. 78100 MAIN STREET #206 - LA QUINTA, CA 92253 `I ( (760)771-2567 rJ` Lic. No.: 771883 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Lice se Class:' B n License No.: 771883 Dater 17i 0 < < ontractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct,. alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she, is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with. Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (55001.: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon; and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ' (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: - LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 I Date: 10/28/11 OCT 2 8 2011 mi WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: - _ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 461001281-2010 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor C e, shall1 forthwith comply with those provisions. a1.te WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance, of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. . I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances apd'state laws relating to building construction, and hereby authorize representatives offtth/i8/ countycto/enter up the above-mentiohed property f i nlsA)pection purposes. date: ` 1 p ignature (Applicant or Agent): t .t..Y.. Application Number . . . . . •11-00001127 Structure Information Construction Type . ... . . TYPE V, UNPROTECTED Occupancy.Type . . . . . MERCANTILE Other struct info . . CODE EDITION 2010• FIRE SPRINKLERS ----------------------------------------------------------------------------- yes Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 25.00 Plan Check Fee 16.25 Issue Date . . . . Valuation 1000 Expiration Date 4/25/12 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 2.0000 HND -BLDG 501-2,000 10.00 Permit.. . . ELECT - ADD/ALT/REM Additional desc Permit Fee 21.75 Plan Check Fee 5.44 Issue Date . . . . Valuation 0 Expiration Date 4/25/12 Qty Unit Charge Per Extension BASE FEE 1 15.00 . 9.00 .7500 PER ELEC DEVICE/FIXTURE IST 20 16.75 ------------------------------------------------- --------------------------- Special Notes and Comments T.I. - ADD 2 NON BEARING WALLS TO CREATE OFFICE AT REAR OF RETAIL BUSINESS. ADD RECEPTACLES AND LIGHT. 2010 CODES. Other Fees . . . . . . . ACCESSIBILITY PLAN REVIEW 1.62 BLDG STDS ADMIN (SB1473) .1.00 ENERGY REVIEW PEE. 1.62 Fee summary Charged Paid Credited Due Permit Fee Total 46.75 .00 .00 46.75 Plan Check Total 21.69 .00 .0.0 21.69 Other Fee Total 4.24 .00 .00 4.24 Grand Total 72.68 .00 00 72.68 LQPERMIT 11 11I y Bin. # City of ` La Qdin to Bulfding fz Safety Division Permit # P.O.'Box 1504,78-495 Calle Tampico I.a.Qulnta, CA 92253 -:(760) 777-7012 • Z-1 Building Permit Application and Tracking Sheet [1 ProjectAddress IL JT Owner's Name: . A- P. Number. Address: 0 0 CCS7,07)"e IC O Legal Description: - City. ST, Zip: C Q • Contractor. Telephone:, Address: Project Description: 2— /V p R 2/wG City, ST, Zip: Pit" 27 I T O k, W 4 I Telephone: State Lie. # : city Lia #; . Arch, EnSr•, Designer Address: City., ST, Zip: Telephoner Construction Type:. Occupancy: State Lie. #: : Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person a %5- # Stories: # nits:. Telephone # of Contact Person: D Estimated Value of Project: Q8Q• OZ) APPLICANT: DO NOTrWRITE 6EL•OW THIS UNE -;i # Submittal ReWd Reed PRA4' HC a n PlsRMi7' FEES 7 Plan Sets Pian Check submitted Mt Amoaat " Struetural Cala Reviewed, ready for corrections Plan Check Deposit. . Truss Cala. Called Contact Pcrsoli-, Plaa Check Balance • --- Title 24 Cates. Pians picked up. d _ .11 J Construction Flood plain plan Pians resubmitted ' Mecbamw Giading plan 2`! Review, ready for correctio e V Electrical Subcontactor List Called Contact Person b Plumbing Groot Deed Plans picked up SMI. H.O.A. Approval Plans resubmitted Grading IN HOUSE•" ''' Review, ready for eorreettons/issuc Developer Impact Fee Planning Approval. Called Contact Person Ax,P.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees 0 y 4Lu.c /zv /ao/ii 1 .. P.O. Box 1504 BUILDING & SAFETY'DEPARTMENT 78-495 ' CALLE TAMPICO' (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To CDD:. /O-/3'// From: Les Johnson, Director -Planning Due Date: 60 -2-0' J Pe'rm it #: Status:—/66' 0_4L Building Plans Approval (This is an approval- toissue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: 2d7x/!j I:GCILG Address or General Location: Applicant Contact: Q41 q - 04-a -3 The Planning Department finds that: 0, ...these Building PI ns do not require Planning Department approval. ... these Building PI ns are approved by the Planning 'Department. 0 ... thes Building Plans require corrections. Please forward a copy of the attache corrections to the applicant.- When the corrections are made ,_Ipleasv eturn them I o the Planning .Department for review. Les ing Mee Veuu' Q C T 13 2010 C4'01 La Quinto a -_ n t Date IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION PROUDLY SERVING THE UNINCORPORATED AREAS October 24, 201 1 OF RIVERSIDE COUNTY AND THE CITIES OF: John R. Hawkins — Fire Chief 210 West San Jacinto Avenue Perris, CA 92570 (951) 940-6900 — www.rvcfire.org RE: TENANT IMPROVEMENT PLAN CHECK -Non Structural RE -DESIGN BANNING LAQ-I I -TI -037 Gracies 78-100 Main St: #101 La Quinta, CA BEAUMONT CALIMESA CANYON LAKE You have been issued a release for a tenant improvement on an existing building. THIS IS NOT. COACHELLA AN OCCUPANCY PERMIT. DESERT HOT SPRINGS It is prohibited to use/process or store any materials in this occupancy that would classify it as an EASTVALE "H" occupancy per Sec. 307 of the 2010 CBC. INDIAN WELLS' ' THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: INDIO JURUPA VALLEY Install door hardware and exit signs as per Chapter 10 of the 2010 CBC. LAKE ELSINORE A minimum 2Al0BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a La QUINTA visible location within 75' walking distance from any point in your building or suite. Fire MENIFEE extinguishers can be installed by.a licensed extinguisher company with a State. Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt MORENO VALLEY attached. A.licensed fire extinguisher company must service extinguisher yearly. PALM DESERT. PERRIS All breakers must be labeled and a clearance of 36 inches, must be maintained around the panel at all times. RANCHO MIRAGE RUBIDOUX CSD Approved suite addresses shall be placed in such a position to be plainly visible and legible from the street. Said'numbers shall contrast with their background. SAN JACINTO TEMECULA An approved audible interior notification alarm device shall be provided. in approved location. A WILDOMAR C-10 licensed contractor must submit plans, designed in accordance with NFPA 72 to the Fire Department for review and approval prior to installation A durable sign stating"This door to remain unlocked during business hours" shall be placed on BOARD OF or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a g SUPERVISORS: contrasting background. BOB BUSTER DISTRICT t Provide key(s) to the tenant space for inclusion in the main building Knox Box. Key(s) shall JOHN TAVAGLIONE have durable and legible tags affixed for identification of the correlating tenant space. Key(s) DISTRICT 2 shall be provided at time of final inspection. JEFF STONE DISTRICT 3 As may be necessary to maintain proper fire sprinkler protection due to constructions changes, JOHN BENOIT fire sprinkler system plans for the tenant improvement area may be required to be submitted to DISTRICT 4 the Fire Department for review. MARION ASHLEY DISTRICT 5 rv- Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A re -inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. Sincerely, . By: Jason Stubble Fire Safety Specialist t OLD TOW111 LA QvirifA October 11, 2011 Building Department City of La Quinta RE: 78100 Main Street # 101, La Quinta CA 92253 To Whom It May Concern: This letter is a confirmation of authorization to allow Gureishii Enterprises, Inc. to construct two Non load bearing. partition walls in the suite referenced above. Said partition walls will be built in accordance with the plan submitted to City of La Quinta Building Department by Gureishii Enterprises, Inc. Sincerely, ILA I. Wells Marvin President Marvin Investments, Inc 'Managing Member for Old Town La Quinta, LLC 6 OCT 13 2011 , 78-100 /V1ain Street, Suite 206 ♦ Ln OtAinto, GA 92253 • (760) 777-17,70 Fox (760) 771-5057 • olcitownlagUinta.com 78-100 Main St 2016 Allowable Area Calculations — Mixed -Multi Story per 506.2.4 Type VB, 2 -Story, Mixed Uses (A-2, B, M), NFPA 13 Actual Areas: 1st Floor 17,481 SF, 2nd Floor 16,999 SF, Total 34,480 SF Allowable Area Formula [Each story to individually comply with 508.1] A-2: 18,000 (SM w/o Height), 1 -Story (Limited to 11t Floor Only) M: 27,000 (SM), 2 -Stories B: 27,000 (SM), 3 -Stories First Floor Aa = At + (NS x If) [Equation 5-1] = 18,000 + (6,000 x.75) Second Floor Aa = At + (NS x If) [Equation 5-1] = 27,000 + (9,000 x.75) = 18,000 + 4,500 = 27,000 + 6,750 = 22,500 SF > 17,481 SF = 33,750 SF > 16,999 SF Public way increase per Section 506.3.3 — Frontage increase If = [ F/P — 0.25] W/30 _ [ 1/1— 0.25 ] 30/30 =[1-0.25] 1 = .75 56,250 SF Allowable > 34,480 SF Existing — Building Complies Most restrictive allowance per Section 508.3 (Nonseparated Occupancies) at each Story with the permitted allowable frontage increases of Section 506. �,opRc