BMCH2016-034651053 Marbella Ct BMCH2016-0346 78-495 CALLE TAMPICO U . LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0346 Property Address: 51053 MARBELLA CT CT APN: 777320005 Application Description: LEAVELL / CHANGE OUT (2) SPLIT SYSTEMS Property Zoning: Application Valuation: $19,800.00 Applicant: PALM DESERT AIR CONDITIONING CO INC DBA 42-081 BEACON HILL PALM DESERT, CA 92211 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Clas : C2) License No.: 374937 la9 t/ Date: lAl b Contractor: 1A/ it OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason' Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: t l VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: MICHAEL LEAVELL 51053 MARBELLA LA QUINTA, CA 92253 Date: 9/13/2016 i' c r Ips C -Z r c Contractor:61 PALM DESERT AIR CONDITIONING -CO INC DBA 42-081 BEACON HILL F PALM DESERT, CA 92211 (760)346-0677 Llc. No.: 374937 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th/g/yv ork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5029447 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I sh forthwith comply with those pr visions. G Date: Applicant: 7 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buildin construction, and hereby authorize representatives of this city to enter upon the above-mengonel property for inspection purposes. C Date: Signature (Applicant or Agent): Application Number: BMCH2016-0346 Property Address: 51053 MARBELLA CT CT APN: 777320005 Application Description: LEAVELL / CHANGE OUT (2) SPLIT SYSTEMS Property Zoning: Application Valuation: $19,800.00 Applicant: PALM DESERT AIR CONDITIONING CO INC DBA 42-081 BEACON HILL PALM DESERT, CA 92211 Date: 9/13/2016 Owner: MICHAEL LEAVELL 51053 MARBELLA LA QUINTA, CA 92253 Contractor: PALM DESERT AIR CONDITIONING CO INC DBA 42-081 BEACON HILL PALM DESERT, CA 92211 (760)346-0677 Llc. No.: 374937 Detail: HVAC CHANGE OUT - (2)185EER/8AFUE SPLIT SYSTEMS [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $145.04 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600. 0 $72:52 Total Paid for CHANGEOUT: $217.56 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $91.85 Total Paid for PERMIT ISSUANCE: $91.85 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) Project Name: LEAVELL, MICHAEL I Date Prepared: CF1R-ALT 02-E (Page 1 of 3 ) 2016-09-13 A. General Information CFIR-ALT 02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF111-ALT-02 document for each dwelling unit. 01 Project Name LEAVELL, MICHAEL 02 Date Prepared 2016-09-13 03 Project Location 51-053 MARBELLA CT. 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name LEAVELL, MICHAEL 07 Zip Code 92253 08 Dwelling Unit Conditioned 2800 _Jnstallin new SC Installin ;:Installing i _'Installing Floor Area (ft2) Iderrtif cation or Location or Area by this SC ducted co aining Number of space conditioning more than 40 09 Climate Zone 15 10 (SC) systems in this dwelling 2 system? component? components? feet of ducts? unit. SC system? B. Space Conditioning (SC) System Information 101 01 02 03 rti x 04 , /0<09' `( + 1t 06; r'"'' ) 07'' p 08 )i s` 09 10 Is the SC "." " .Installing ate" Sq System SCS stem CFA served s stem a° r ria nt ` _Jnstallin new SC Installin ;:Installing i _'Installing Iderrtif cation or Location or Area by this SC ducted co aining system more than 40 entirely ew entirely new dame Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 LIVING SPACE 1600 Yes Yes Yes No No No Altered space conditioning system System 2 BEDROOMS 1200 Yes Yes Yes No No No Altered space . conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 15O.2(b)1Diib) This section does not apply to this project. -Registration Number: 216-A0337618A-000000000-0000 CA Building Energv Efficiencv Standards - 2013 Residential Compliance Registration Date/Time: 2016-09-13.12:17:16 Report Version: 2013 Rev 1.008 HERS Provider: CaICERTS Report Generated: 2016-09-13 12:17:03 CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) O1 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new Less than or System 1 furnace heating AFUE g AC cooling SEER 18 Setback equal to 40 R-8 components components feet Central gas All new Central split All new Less than or System 2 furnace heating AFUE g AC cooling SEER 18 Setback equal to 40 R-8 components components feet Required Documentation: CF2R-MCH-01-E -Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: <_ 15%, ors 10% leakage to outside, or seal all accessible leaks. , r-Mw V►-. . - CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification containing components in CT2,i 8-15). required when.refngerant CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH -25 is required )) +r Exceptions: j[ i are installed { or altered,(applicable t S' ;rpi + -Duct systems registered with HERS provider as previously sealed are exempt from'MCH;20 Duct.Le6akagewjee ting requirements. -Heating-only systems and Air Handler/Furnace changes do not require' verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH 2 Duc 'Leel akage TTesting req remen s i .. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 216-A0337618A-000000000-0000 Registration Date/Time: 2016-09-13 12:17:16 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 ' Report Generated: 2016-09-13 12:17:03 CERTIFICATE OF COMPLIANCE CF111-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: `7/G li/G'liB McCoy, William Company: Signature Date: Palm Desert Air Conditioning Co 2016-09-13 12:17:16 Address: CEA/ HERS Certification Identification (if applicable): 42-081 Beacon Hill City/State/Zip: r Phone: Palm Desert CA 92211 760-346-0677 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The in provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the.Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the F —. requirements of Title 24, Part 1 and Part hof the California Code of Regulations.;Cancet"itherlappllcab le compliance .4. The building design features or system design features identified on this Certifc of Complre consistent with the information.provided o documents, worksheets, calculations, plans and specifications submitted to the en forcemen' agency for.approval wit( this building permit application. 7 PP 5. 1 will ensure that a registered copy ofihis'Certificate of Compliance shall be made available wiih;the building permit(s),issued forthe building, and made available to the'enforcement agency for all applicable . inspections. I understand that a registered copy of thTis Certjficate of Ccmplliance iis,requireed to be -included with the: datum enttation the builder provides to. the building owner at occupancy. Responsible Designer Name: ` , S Responsible Designer Signature: V _ f ,« " / Mal;W/01 McCoy, William Company: Date Signed: Palm Desert Air Conditioning Co 2016-09-13 12:17:16 Address: License: 42-081 Beacon Hill 374937 City/State/Zip: Phone: Palm. Desert CA 92211 760-346-0677 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. i Registration Number: 216-A0337618A-000000000-0000 Registration Date/Time: 2016-09-13 12:17:16 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-13 12:17:03 srr,. Qty Of .U. Qulhta Building 8t Safety Division P.O. Box 1504,78-49S Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application' and Tracking Sheet Permit # Address: 51-053 MARBELLA CT.. Owner's Name:. LEAVELL, MICHAEL [Project A. P. Number. Address: 51-053 MARBELLA CT. Legal Description: RESIDENTIAL City, ST, Zip: 92253 Contractor. PALM DESERT A/C CO. INC. Telephone: 760-771-6107 .tem mss' . , ; Address: 42-081 BEACON HILL Project Description: Change out of (2) HEATING AND City, ST, Zip: PALM DESERT CA. 92211. COOLING SYSTEMS, THE FIRST IS A (3) TON, THE Telephone: 760-346-0677 r 1j. V " - r ,a z,;' 'Z SECOND IS A (4) TON: BOTH ARE A (18) seer AND (13) EE State Lic. # : 3.74937 City Lie'. #; LIC-0100886 AMERICAN STANDARD AND BOTH ARE HORIZONTAL Arch, Engr., Designer. SYSTEMS. THERMOSTATS- PROGRAMMABLE/ WI FI, Address: $19,800.00 . City., ST, Zip: Telephoner State Lic. #:r% Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Univ: Telephone # of Contact Person: Estimated Value of Project: ill)0 ` APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACMG PERMIT FEES Plan Sets Plan Check submitted item Amount Structural Calm Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person Plan Check Balance. Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted.. Mechanical Grading plan 2ad Review, ready for correctionsfissue Electrical Subcoatactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review; ready for correcdons/issue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees