RER (12-0063)50181 Calle Maria
12-0063
i
P.O. -BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
"`&t / 4 44 Q"
Y Application Number: dC!--.12.=0 00.00063_;
Property Address: X0181 CALLE MARIA
APN: 773-340-015-15 -14496 -
Application description: REMODEL - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 25000
Applicant: Architect or Engineer:
CoNTAA tJ i' T psi
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153,
Date: 2/16/12
Owner:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury tha em licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
' BENDER,KEVIN P .
_ I have and will maintain a.certificate of consent to self -insure for workers' compensation, as provided
License Class: B C54 Li nse No.: 655861
for by Section 3700 of the Labor Code; for the performance of the work for which this permit is
533 GEORGIAN RD
issued.
X. Date: ° ' (' / -e"ontractor: -44
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
LA CANADA, CA 91011
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier ULLICO CASUALTY Policy Number LTWIC48500015111
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a peimit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the'
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I shoue become subject to the rkers' compensation provisions of Section
Contractor:
- 3700 of the labor , I shall forthwith compith those provisions.
FEB 17
2032
GALATI ENTERPRISES
IIS
I, as.owner of the property, or my employees with wages as their sole compensation, will do the work, and
78050 CALLE CADIZ
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
CITEOFLA QUI
LA QUINTA, CA 92253
• and who does the work himself or herself through his or her own employees, provided that the
i ✓ j;: j;
- improvements are not intended or offered for sale. If, however, the building or improvement is sold within
(760)777-9994
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
Lic. No.: 655861,
( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec..
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the -
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
LICENSED CONTRACTOR'S DECLARATION
officers
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury tha em licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the eusine and ProfessionalsC de, and my License is in full force and effect.
_ I have and will maintain a.certificate of consent to self -insure for workers' compensation, as provided
License Class: B C54 Li nse No.: 655861
for by Section 3700 of the Labor Code; for the performance of the work for which this permit is
N q /J
issued.
X. Date: ° ' (' / -e"ontractor: -44
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION
insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
Carrier ULLICO CASUALTY Policy Number LTWIC48500015111
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a peimit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the'
person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I shoue become subject to the rkers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
- 3700 of the labor , I shall forthwith compith those provisions.
that. he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
!y
1
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
any
"IR ' 2--PP"cant:
I, as.owner of the property, or my employees with wages as their sole compensation, will do the work, and
" the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not applyto an owner of property who builds or improves thereon,
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
• and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
- improvements are not intended or offered for sale. If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S. FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
APPLICANT ACKNOWLEDGEMENT
( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec..
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the -
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
conditions and restrictions set forth on this application. .
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
1. Each person upon whose behalf this application is made, each person at whose request and for
- pursuant to the Contractors' State License Law.).
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
' (_) I am exempt under Sec. , B.&P.C. for this reason
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
f L O 'nt t a ents and em Io ees for an act or omission related to the work bein
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued ISec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
k
LQPERMIT
o a w a, i s o ice g p y y g
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced -
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the abov information is torr I agree to comply with all
city and county ordinances and state laws relating to buildin nstruction, and h y authorize representatives
of this county to enter upon the above-mentioned prop " r inspection purpo
Da e. liSfgnature (Applicant or Agentl:
Rl
.'l
Application Number . . . 12-00000063
----- Structure Structure Information WINDOW CHANGE OUT AND ALTERATION
-----
Other struct info . . . . . CODE EDITION 2010
----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional'desc .
Permit.Fee . . . . 252.00 Plan Check Fee
163.80
Issue Date . . . . Valuation . . . ..
25000
Expiration Date 8/14/12
Qty Unit Charge Per
Extension
BASE FEE
45.00
23.00 9.0000 THOU BLDG 2,001-25,000
----------------------------------------------------------------------------
207.00.
Permit :,. ELECT - ADD/ALT/REM
Additional desc..
Permit Fee . . . . 18.75 Plan Check Fee'.
4.69
Issue Date . . . . Valuation
0
Expiration Date 8/14/12
Qty Unit Charge Per
Extension
BASE FEE
15.00
5.00 .7500 PER ELEC DEVICE/FIXTURE-IST 20
3.75
-------=--------------------------------------------------------------------
Special Notes and Comments
WINDOW CHANGE OUT THROUGHOUT DWELLING
WITH ALTERATION OF EXISTING OPENINGS AT
REAR PATIO TO ACCOMMODATE NEW SLIDING
GLASS DOOR SYSTEM [ENGINEERED] THIS
PERMIT DOES NOT INCLUDE ADDITIONAL
CONDITIONED SQUARE FOOTAGE. 2010
CALIFORNIA BUILDING CODES.
February 16, 2012 2:58:44 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE
16.38
STRONG MOTION (SMI) - RES
2.50
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 270.75 .00 .00
270.75
Plan Check Total 168.49 .00 .00
168.49
Other Fee Total 18.88 .00 .00
18.88
Grand Total 458.12 .00 .00
458.12
LQPERMIT
123
tj
3 12 c- 9S 04G
_.
eta. # City Of lel Quin: t' a
Bulk ft 8[ Safety D14dim
Penwt # P.O. Box 1504,78-495 Calle Tampico
,f 3 La.Quinta, CA 92253.:(760) 777-7012
1 SCJ Building Permit Application, and Tracking Sheet :
Projxt Address: ( g CQ Owner's Nae:.
VI II
A. P. Number. Address: SLo g ( CQ 1 e G.r'l `
Legal Description: City, ST, Zip: Z
. q ► : ; CA- 9
Contractor. C l • U Telephoner! Col 3 3 `i SCo
Address: j O O c Cq cll ' Project Description:
City, ST, Trp: Ci Q ut (nom. Gq- . q 2,Z5
Telephone: -%(ot; 11
State Lia # : (55 (o l City Licc. #; Li 9 1'VEngr., Designer. p T A -('ch l
Address: -70 2,66 H w ' I t 4-e Io
City., ST, Zip' RQnd,(o i rq C 12,-7O
Telephone:"165,0 3zy gG44 Construction Type-. Occupancy:
State Lic. M C --3$ typ
Project e (circle one): New Add, Alter air Demo
Name of Contact Person: DlqA Tk p (-A to U rL4 Sq. FL: # Stories: # Units:
Telephone # of Contact Person: -1LQ . 2 - Estimated Value of Proj2Zect CS•CX3 —
APPLICANT: DO NOT WRITE BELOW THIS UNE
# Submittal RWd ReNd TRAC MiG PERMIT FEES
Plon Seta Plan Check submitted tits Item Amount
Strndond Cala. Reviewed, ready for corrections Pbun Check Deposit. .
Truss Cake. Called Contact Person Platt Cheek Balance
Title 24 Cates. Pians picked up 3 Canstraction I.
Flood plain plan Plana resubmitted.. 3 2 MechanicalGiading plan Z'! Review, ready for corrcetio Electrical
Sabeoatactor Lint Called Coutaet Person ti Plumbing
Grant Deed Plane picked up S.M.I.
H.O.A. Approval Plans resubmitted Grading
nV HOUSE:- ""Review; ready for cometionalbsue Developer Impact Fee
Planning Approval Called Contaet Person P.
Pub. Wks. Appr - Date of permit Issue
School Fees
Total Permit
Fees
123
tj
3 12 c- 9S 04G
_.
eta. # City Of lel Quin: t' a
Bulk ft 8[ Safety D14dim
Penwt # P.O. Box 1504,78-495 Calle Tampico
,f 3 La.Quinta, CA 92253.:(760) 777-7012
1 SCJ Building Permit Application, and Tracking Sheet :
Projxt Address: ( g CQ Owner's Nae:.
VI II
A. P. Number. Address: SLo g ( CQ 1 e G.r'l `
Legal Description: City, ST, Zip: Z
. q ► : ; CA- 9
Contractor. C l • U Telephoner! Col 3 3 `i SCo
Address: j O O c Cq cll ' Project Description:
City, ST, Trp: Ci Q ut (nom. Gq- . q 2,Z5
Telephone: -%(ot; 11
State Lia # : (55 (o l City Licc. #; Li 9 1'VEngr., Designer. p T A -('ch l
Address: -70 2,66 H w ' I t 4-e Io
City., ST, Zip' RQnd,(o i rq C 12,-7O
Telephone:"165,0 3zy gG44 Construction Type-. Occupancy:
State Lic. M C --3$ typ
Project e (circle one): New Add, Alter air Demo
Name of Contact Person: DlqA Tk p (-A to U rL4 Sq. FL: # Stories: # Units:
Telephone # of Contact Person: -1LQ . 2 - Estimated Value of Proj2Zect CS•CX3 —
APPLICANT: DO NOT WRITE BELOW THIS UNE
# Submittal RWd ReNd TRAC MiG PERMIT FEES
Plon Seta Plan Check submitted tits Item Amount
Strndond Cala. Reviewed, ready for corrections Pbun Check Deposit. .
Truss Cake. Called Contact Person Platt Cheek Balance
Title 24 Cates. Pians picked up 3 Canstraction I.
Flood plain plan Plana resubmitted.. 3 2 MechanicalGiading plan Z'! Review, ready for corrcetio Electrical
Sabeoatactor Lint Called Coutaet Person ti Plumbing
Grant Deed Plane picked up S.M.I.
H.O.A. Approval Plans resubmitted Grading
nV HOUSE:- ""Review; ready for cometionalbsue Developer Impact Fee
Planning Approval Called Contaet Person P.
Pub. Wks. Appr - Date of permit Issue
School Fees
Total Permit
January 19, 2012 ,
Kevin Bender
355 S Grand Avenue
Suite 2700
Los Angeles, CA 90071 .
Dear Mr. Bender,
The Architectural Committee has approved your January 11 Change Application for new
windows (including reconfiguring the patio sliders) at 50181 Calle Maria.
We have on hand all of the required insurance documents and the signed Jobsite Rules
from your contractor Galati Enterprises/Total Construction.
s
i
Please let us know when the project has been completed, and we will inspect the work;
then we'll issue you a refund of your $500 deposit.
Best regards,
Dave Scott, CCAM
Community Association Manager
Santa Rosa Cove Association
- i VJCIF11V w -'D 3
JAN 2 3 2012
BY:
• i
49-991 Eisenhower
La Quinta, California
SRC(760) 777-841
Fax: (760) 56484L8
Mailing Address:
SANTA ROSA COVE ASSOCIATION • Paln,DeeerrtCA12920
92255
t
e 71.=7.80 San ;Jacinto Dr_'Ste. E2; Rancho Wg q;;.Q4. 92270 ph.;
4 Letter of Transmittal
To: City of La Quinta Today's Date: 2-9-12
Structural Plan Review Time =.75 Hrs.
This Material Sent for:
❑ Your Files
❑ Your Review
❑ Checking
Other: ❑
By: John W. Thompson
Rancho Mirage Office: ® (760) 834-8860
Other. ❑ ;
® Per Your Request
❑ Approval
❑ At the request of: _
78-495 Calle Tampico . City Due Date:
2-10-12
La Quinta, CA 92253 Project Address:
50-181 Calle Maria
Attn:
Kay Plan Check #:
12-63
Submittal: ❑ 1st
❑
4tn
® 2nd
❑
5th
❑ 3`d
❑
Other:
We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions: Includes:
# Of Descriptions:
Copies:
Copies:
❑
Structural Plans
®.
1 Revised Structural Plans
❑
Structural Calculations
®
1 Revised Struct. Calcs
❑
Truss Calculations
l7
Revised Truss
❑
Soils Report
❑
Revised Soils Report
®
1 Structural Comment List
❑
Approved Structural Plans
®
1 Redlined Structural Plans
❑
Approved Structural Calcs
®
1 Redlined Structural Calcs
❑
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
❑
Other:
Comments: Structural content is aaarovable.
I II f It3 [I^ i M f2 r
Structural Plan Review Time =.75 Hrs.
This Material Sent for:
❑ Your Files
❑ Your Review
❑ Checking
Other: ❑
By: John W. Thompson
Rancho Mirage Office: ® (760) 834-8860
Other. ❑ ;
® Per Your Request
❑ Approval
❑ At the request of: _
daniel k. thombury' ala.
'
—AR C H I T E C T
70-390 Highway 111 Sufte 100
Rancho Mirsoe. CalHomM _ _ 92270
A _ CA 'I
INPUT DATA 8 DESIGN SUMMARY
MEMBER SIZEry;.: ,..,:..•,. .... ..•.• ,C-,1,
..'•lL ; : ;fl$"l .r: : tiOluhyn24F-1.8E
MEMBER SPAN L = :`f35':' ft I t 96
":. .
UNIFORMLY DISTRIBUTED DEAD LOAD
woFTTM
UILDING & SAFETY DEPT.
7.
w ,. Iha / ft
APPROVED
r 5 N fi - RE5
FOR CONSTRUCTION
0-181 GoLL.E MPFLIL .
._CQ.'62UINTla`IG4
—
Z I 0 l2
DATE BY
C'RE1 t tz 1' 13Y: t taNlEL T o2W}3UR P:I,A, 1'j•oOle
INPUT DATA 8 DESIGN SUMMARY
MEMBER SIZEry;.: ,..,:..•,. .... ..•.• ,C-,1,
..'•lL ; : ;fl$"l .r: : tiOluhyn24F-1.8E
MEMBER SPAN L = :`f35':' ft I t 96
":. .
UNIFORMLY DISTRIBUTED DEAD LOAD
woFTTM
UNIFORMLY DISTRIBUTED LIVE LOAD
w ,. Iha / ft
:...::: • No
CONCENTRATED DEAD LOADS
PO1FFTTT
(0 for no oonoeritrated Ioad)
✓4 '.`t:':4i • R
Poo
1 0.90
Dead Load
2 1.00
OooVwcy Lim Load
DEFLECTION LIMIT' OF LIVE LOAD
d = L I ` (i r<
Camber 0.43 inch
DEFLECTION LIMIT OF LONG-TERM
d..,o., = L!. _. ^
FEB 0 3 2012
THE BEAM DESIGN IS ADEQUATE
Does member have oorntlrttxKn lateral support by top draphragm ? .
(1= yes, 0= r,)
:...::: • No
i Duration
Factor. C . C4ndbon
R1EclrJ v PD
1 0.90
Dead Load
2 1.00
OooVwcy Lim Load
3 1.15
Snow Load
FEB 0 3 2012
4 1.25'
Construction load
.
5 1,6Q• •:
WadlEarthquakaLoad
6 2.00
knpect Load
Choice >
4 .. : Construction Load
t
By ,
ANALYSIS
DETERMINE REACTIONS, MOMENT, SHEAR
wsrw = 9
lbs / ft 3.44 k%w
Rww
3.44 Idpa
V..Q = - 2.93
lips, at 12 Inch from left end
Mu.. _
1159
&Idps, at 6.75 ft from left and
DETERMINE SECTION
PROPERTIES& ALLOWABLE STRESSES
b = 3.13
in E',,,I„ = SM lsi
E- E.=
1800
ksi Fb = 3000 psi
d = 12.00
in FbE 3027 psi
Fb -
2,400
psi F = FbE / Fb = 1.01
A - 37.5
1 . 450 le
Fv •
265
psf Fb: = 2,463 psi
S. - 75.0
h Ra = 18.7f]2 < 50
E =
1,11M
ksi F,, = 331 psi
I E = 25.0
(ft. -Tab 3.3.3 tooUnote 1)
Co Crit
Cl Cl . CL CF CV
Ca
Cr
125
0.82 1.00 1.00
1,OU
CHECK BENDING AND SHEAR CAPACITIES
fb = MM. / S„ = 1855 . psi < Fb 2463 psi [Satisfacfoiy]
f„' =1.5 Vu.'/ A = 117 psi < Fv . "[Satisfactory]
CHECK DEFLECTIONS
0.18 In, at 6.750 ft from left end, < 14 - L 1 360
A 0.47 In. of 6.750ftfrom left end < d,"o.L,L/240
Where Ka (NDS 3.52)
DETERMINE CAMBER AT 1.5 (DEAD • SELF WEIGHT)
d wso. y.o a 0.43 In, at &750 ft from left and
r
(Satisfactory]
[Satisfactory]
V/
dkf'daniel k. thornbury' a.i.a.
A R C H I T E C T
70-390 Hlphway 111 Suite 100
Rancho Mirage, California 92270
tel.: (760) 324-8544 fax: (760) 324-8543
erns((: dlaarchiteccyahoo.com
FE► , 2.,..202 ,
_. ENOER RES.
- 1$I G4LL6 M4,RIC.
p pr,RE-7-0 -Fby ; r>/'N IELTLIoRNr3UA-Y f. A.
(CHECK THE BEAM CAPACITY WITH AXIAL LOAD
AXIAL LOAD F kips
THE ALLOWABLE COMPRESSIVE STRESS IS
FT
Fe = Fc Co Cr Cr - 233 gel
t
Where Fe- a 1500 PM
F F
Co = 1.60
-
Cr = 1.00 (Lumber only)
_.._
Cp = (1+F) 12c - I(1+•F) 12c)? - F ! C)"
0.097
Fa = Fa Co Cr = 2400 pea
I_ = K L - 1.01- 162 In
b = 3.5 in
SF = slenderness ratio 46.3 <
50 (Satisfies NDS 2005 Sea 3.7.1:41
F8 m 0.822 E'er„/SFS = Me psl
e„w, = 62o Ial
F. = F.E IF.* = 0.099
C m 0.8
THE ACTUAL COMPRESSIVE STRESS IS
4 a F / A = .0 psi < Fa
[Satisfactory)
E ALLOWABLE FLEXURAL STRESS IS
Fs = 1487 PA I for Co = 1.6 j
THE ACTUAL FLEXURAL STRESS IS
fp = (M + Fe) / S = 1031 psi < F
(Satisfactory)
CHECK COMBINED STRESS IND6 2005 See. 3.92)
(fa I Fo + % I [F.(1 - fa I F,J) 0.693. <
1 ISafisfactOry)
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Bender Residence
50-181 Calle Maria
Palm Desert, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352 ` -
A901L.d. • 10% - _._►
CITY -F LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
JAN 2, 2012
Job Number: Sy
DATE BY
Date:
1/24/2012
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
Energ.LPra 5.1 by EnergySoft User Number: 2655 RunCode: 2012-01-24715:56:18 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 11
HVAC System Heating and Cooling Loads Summary 14
• f
EnergyPro 5.1 by EnergySoft Job Number ID: User Number. 2655
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Bender Residence
Building Type ® Single Family ❑ Addition Alone
13 Multi Family ® Existing+ Addition/Alteration
Date
1/24/2012
Project Address
50-181 Calle Maria Palm Desert
_
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,280
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 2,280 Perim = 120' Existing
Wall Wood Framed
R-11 1,547 Existing
Door Opaque Door
None 40 Existing
Roof Wood Framed Attic
R-22 2,280 Existing
FENESTRATION U-
Orientation Area( Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (NIAq 16.6 0.500
0.33 2.0 none Bug Screen
New
Front (NV4 13.7 0.500
0.33 2.0 none Bug Screen
New
Left (NE) 17.5 0.500
0.33 2.0 none Bug Screen
New
Left (NE) 17.5 0.500
0.33 2.0 none Bug Screen
New
Left (NE) 23.6 0.500
0.33 2.0 none Bug Screen
New
Left (NE) 18.5 0.500
0.33 2.0 none Bug Screen
New
Left (NE) 48.0 0.510
0.32 2.0 none Bug Screen
New
Left (NE) 27.4 0.500
0.33 2.0 none Bug Screen
New
Rear (SE) 48.0 0.510
0.32 2.0 none Bug Screen
New
Rear (SE) 16.0 0.500
0.33 2.0 none Bug Screen
New
Rear (SE) 27.4 0.500
0.33 2.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
EnergyPro 5.1 by Energy5oft User Number: 2655 RunCode: 2012-01-24715:56:18 /D:
Page 3 of 14
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Bender Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
1/24/2012
Project Address
50-181 Calle Maria Palm Desert
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,280
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ® No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area( Factor SHGC Overhang Sidefins Shades Status
Rear (SE) 107.5 0.510 0.32 2.0 none Bug Screen
New
Right (SVV) 18.5 0.500 0.33 2.0 none Bug Screen
New
Right (SKO 18.5 0.500 0.33 2.0 none Bug Screen
New
Right (SV-9 45.0 0.510 0.32 2.0 none Bug Screen
New
Right (SVIO 16.0 0.500 0.33 2.0 none Bug Screen
New
Right (SVt9 23.3 0.500 0.33 2.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value
Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
rE—nergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012.01-24715:56:18 /D:
Page 4 of 14
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Bender Residence
Building Type ® Single Family ❑ Addition Alone -
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date.
1/24/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnerovPro 5.1 by EnengySoft User Number: 2655 RunCode: 2012-01-24715:56:18 ID: Page 5 of 14
PERFORMANCE CERTIFICATE: Residential Hart 3 or 5 L;1_-1 r
Project Name
Building Type m Single Family 13 Addition Alone
Date
Bender Residence
t7 Multi Family 10 Existing+ Addition/Alteration
112412012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 11.73 8.47 3.26
Space Cooling 153.55 116.91 36.64
Fans 32.65 24.93 7.72
Domestic Hot Water 1713 17.13 0.00
Pumps 0.00 0.00 0.00
Totals 215.05 167.43 47.62
Percent Better Than Standard: 22.1%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
enestration
Building Front Orientation: (NIA9 315 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NM 590 30
Fuel Available at Site: Natural Gas (NE) 450 153
Raised Floor Area: 0 (SE) 600 199
450 121
Slab on Grade Area: 2,280 (SW
' o
Average Ceiling Height: 8.0 Roof 2,280
Fenestration Average U-Factor: 0.50 TOTAL: 503
Average SHGC: 0.33 Fenestration/CFA Ratio: 22.1%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations..
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.i 112412012
Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker
-City/State/ZipPalm Desert, Ca 92211 Phone 760-345-1352 i ned Date
-City/State/Zip
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company i IJ1l3U 14 • TNv2 Jf2'0 4y /l- i R .
Address '70-'3`IO 14avy, t/r 1> Ivo Name T%ANIC-(,.-' Aojz/Jriui'L`1 • 2 2
J7_AxX'h'V 1. G•ta Phone ° rt ` S Signed License # Date
City/State/Zip .
22%D
EnemvPro 5.1 b Ene Soft User Number: 2655 RunCode: 1012-01-24r15:56:18 /D: Page 6 of 14
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Bender Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1112412012
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
2,280
0.730 None
0 180 Existing 4.4.7-A1
Existina Livin
Wall
520
0.110 R-11
315 90 Existing 4.3.1-A2
Existing Living
Door
40
1.450 None
315 90 Existing 4.5.1-A 1
Existing Living
Wall
298
0.110 R-11
45 90 Existing 4.3. i -A2
Existing Living
Wall
401
0.110 R-11
1
1 1351 90 1 Existing 4.3.1-A2
Existing Living
Wall
329
0.110 R-11
225 90 1 Existing 4.3.1-A2
Existing Living
Roof
2,280
0.043 R-22
315 0 Existing 4.2.1-A6
Existing Living
FENESTRATION SURFACE DETAILS
ID
Type
Area Ll -Factor'
SHGC
Azm Status Glazing Type
Location/Comments
1
Window
13.7 1.190 Default
0.83 Default 315 Removed Single Metal Clear
Existing Living
2
Window
16.6 1.190 Default
0.83 Default 315 Removed Single Metal Clear
Existing Living
3
Window
16.6 0.500 NFRC
0.33 NFRC 315 New Sliding Window
Existina Livin
4
Window
13.7 0.500 NFRC
0.33 NFRC 315 New Sliding Window
Existing Living
5
Window
17.5 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
6
Window
17.5 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
7
Window
23.6 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
8
Window
18.5 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
9
Window
48.0 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
10
Window
27.4 1.190 Default
0.83 Default 45 Removed Single Metal Clear
Existing Living
11
Window
17.51 0.500 NFRC
0.33 NFRC 45 New Sliding Window
Existing Living
12
Window
17.5 0.500 NFRC
0.33 NFRC 45 New Sliding Window
Existing Living
13
Window
23.6 0.500 NFRC
0.33 NFRC 45 New Sliding Window
Existing Living
14
Window
18.5 0.500 NFRC
0.33 NFRC 45 New Sliding Window
Existing Living
15
Window
48.0 0.510 NFRC
0.32 NFRC 45 New Sliding Door
Existing Living
16
Window
27.4 0.500 1 NFRC
0.33 NFRC 45 New Sliding Window
Existing Living
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
-Hqt Wd
Ove hang Left Fin
Len Hot I LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
4.01 4.0 2.0 0.1 2.0 2.0
2
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
3
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
4
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
5
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
6
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
7
Bug Screen
0.76
4.01 4.0 2.0 0.1 2.0 2.0
8
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
9
Bug Screen
0.76
8.0 6.0 2.0 0.1 2.0 2.0
10
Bug Screen
0.76
4.0 4.0 2.01 0.1 2.0 2.0
11
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
12
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
13
Bug Screen
0.76
4.01 4.0 2.0 0.1 2.0 2.0
14
Bug Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
15
Bu Screen
0.76
8.0 6.0 2.0 0.1 2.0 2.0
16
Bu Screen
0.76
4.0 4.0 2.0 0.1 2.0 2.0
EnergyPro
5. 1_by EnergySoft User Number 2655 RunCode: 2012-01-24715:56:18 ID:
Page 7 of 14
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Bender Residence
Building Type m Single Family O Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
11124/2012
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
-Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
--------------
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
17
Window 48.0
1.190 Default
0.83 Default
135 Removed Single Metal Clear
Existing Living
18
Window 16.0
1.190 Default
0.83 Default
135 Removed Single Metal Clear
Existing Living
19
Window 16.0
1.190 Default
0.83 Default
135 Removed Single Metal Clear
Existing Living
20
Window 16.0
1.190 Default
0.83 Default
135 Removed Single Metal Clear
Existing Living
21
Window 1 27.4
1.190 Default
0.83 Default
135 Removed Single Metal Clear
Existing Living
22
Window 48.0
0.510 NFRC
0.32 NFRC
135 New Sliding Door
Existing Living
23
Window 16.0
0.500 NFRC
0.33 NFRC
135 New Sliding Window
Existing Living
24
Window 27.4
0.500 NFRC
0.33 NFRC
135 New Sliding Window
Existing Living
25
Window 107.5
0.510 NFRC
0.32 NFRC
135 New Sliding Door
Existing Living
26
Window 18.5
1.190 Default
0.83 Default
225 Removed Single Metal Clear
Existing Living
27
Window 18.51
1.190 Default
0.83 Default
225 Removed Single Metal Clear
Existing Living
28
Vtrindow 45.0
1.190 Default
0.83 Default
225 Removed Single Metal Clear
Existing Living
29
Window 16.0
1.190 Default
0.83 1 Default
225 Removed Single Metal Clear
Existing Living
30
Window 23.3
1.190 Default
0.83 Default
225 Removed Single Metal Clear
Existing Living
31
Window 18.5
0.500 NFRC
0.33 NFRC
225 New Sliding Window
Existing Living
32
Window 18.5
0.500 NFRC
0.33 NFRC
225 New Sliding Window
Existing Living
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove anq
Len H t LEA RExt Dist I
Left Fin Ri ht Fin
Len Hcjt Dist Len H t
17
Bug Screen
0.76
6.0 8.0
2.0 0.1 2.0 2.0
18
Bug Screen
0.76
2.5 12.0
2.0 0.1 2.0 2.0
19
Bug Screen
0.76
4.0 4.0
2.0 0.1 2.0 2.0
20
Bug Screen
0.76
6.0 8.0
2.0 0.1 2.0 2.0
21
Bug Screen
0.76
2.5 12.0
2.0 0.1 2.0 2.0
22
Bug Screen
0.76
6.0 8.0
2.0 0.1 2.0 2.0
23
Bug Screen
0.76
2.5 12.0
2.0 0.1 2.0 2.0
24
Bug Screen
0.76
2.5 12.0
2.0 0.1 2.0 2.0
25
Bug Screen
0.76
2.5 12.0
2.0 0.1 2.0 2.0
26
Bug Screen
0.761
6.0 3.0
2.0 0.1 2.0 2.0
27
Bug Screen
0.76
6.01 3.0
2.0 0.1 2.01 2.0
28
Bug Screen
0.76
6.0 3.0
2.01 0.1 2.0 2.0
29
Bug Screen
0.76
6.0 3.0
2.0 0.1 2.0 2.0
30
Bug Screen
0.76
6.0 3.0
2.0 0.1 2.0 2.0
31
Bug Screen
0.76
6.0 3.0
2.0 0.1 2.0 2.0
32
1Bug Scree
1 0.76
6.0 3.0
2.0 0.1 2.0 2.01 1
EnergyPro
5.1 by EnergySoft
User Number: 2655 RunCode: 2012-01-24715:56:18 ID:
Page 8 of 14
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Bender Residence
Building Type 0 Single Family 0 Addition Alone
0 Multi Family m Existing+ Addition/Alteration
Date
1112412012
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Intedorl Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC4
Azm Status Glazing Type Location/Comments
33 Window 45.0 0.510 NFRC 0.32 NFRC 225 New Sliding Door Existing Living
34 Window 16.0 0.500 NFRC 0.33 NFRC 225 New Sliding Window Existing Living
35 Window 23.3 0.500 NFRC 0.33 NFRC 225 New Sliding Window Existing Living
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hahq Left Fin Ri ht Fin
Len Hot LExt RExt Dist Len Hot Dist Len H t
33 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0
34 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0
35 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0
EnergyRnp 5.1 by EnergySoft User Number. 2655
RunCode: 2 012-01-24 715:56:18 /D: Page 9 of 14
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Bender Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1112412012
BUILDING ZONE INFORMATION
System Name Zone Name New
Floor Area
Existinq Altered Removed Volume Year Built
Living Zone Existing Living
2,280
18,240 1978
Totals 01 2,280 0 01
1
HVAC SYSTEMS
System Name Oty. Heating T pe Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone 1 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating Cooling
Duct
Duct Location R -Value
Ducts
Tested?. Status
Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
❑
WATER HEATING SYSTEMS
S stem Name
O
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40.000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C
0
m
a
a —
System Name
Pipe '
Len th
Pipe
Diameter
Insul.
Thick.
Oty.
HP
Plenum Outside Buried
1
01
13
EnergyPro 5.1 by EnergySoft User Number.- 2655 RunCode: 2012-01-24x15:56:18 ID:
Pae 10 o771
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Bender Residence
Date
1/24/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (•) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
4150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
4150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1506)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2012-01-24715:58:18 ID: Page 11 of 14
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
1/24/2012
Bender Residence
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
601,
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
than 1/4 inch, the combination of mastic and either mesh or tape shall be used
used to seal openings reater
§150(m)l : Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools or s s that have a heat pump or as heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only duhn off-peak electric demand periods.
§150(p): Residential pool systems orequipment meet the purnp sizing, flow rate, piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lightinq integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergysoR User Number.- 2655 RunCode: 2012-01-24T15:56:18 /D: Page 12 of 14
GENERAL NOTES
I .ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT EDITIONS. OF ALL'ADOPTED CODES -AND
ORDINANCES IN EFFECT AT THE PLACE OF WORK. NOTHING IN'THE5E IDRAWING5 AND/OR
SPECIFICATIONS SHALL BE INTERPRETED TO ALLOW NON -CONFORMING WORK.
2. PRIOR TO THE START OF ANY WORK THE CONTRACTOR SHALL VERIFY (WITH ALL TRADES) ALL
DIMENSIONS AND EXISTING CONDITIONS AT THE JOB AND HE SHALL BE RESPONSIBLE FOR
ANY DISCREPANCIES BETWEEN DIMENSIONS AND CONDITIONS OF ACTUAL WORK AND THOSE
ON THE DRAWINGS.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL QUANTITIES OF MATERIAL AND/OR EQUIPMENT
REQUIRED TO PROPERLY COMPLETE THE WORK.
4. ALL CONTRACTORS AND/OR OWNER -BUILDERS MUST SUBMIT CERTIFICATE OF WORKERS
COMPENSATION INSURANCE COVERAGE PRIOR TO ISSUANCE OF A BUILDING PERMIT PER
CALIFORNIA LABOR CODE, SECTION 3700
5. GENERAL CONTRACTORS AND/OR OWNER -BUILDER SHALL COMPLETE AND SUBMIT A CONTRACTORS LIST
FORM TO THE DEPARTMENT OF CODE COMPLIANCE.
G. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL
BUILDING MATERIALS.
7. STORAGE OF BUILDING MATERIAL OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT
IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR ITHIS PURPOSE UNLESS WRITTEN
PERMISSION OF THE OWNER 15 ON FILE WITH THI5 OFFICE. THE PUBLIC RIGHT-OF-WAY SHALL BE
MAINTAINED IN A CLEAR CONDITION AT ALL TIMES UNLESS AN ENCROACHMENT PERMIT 15 OBTAINED
FROM THE PUBLIC WORKS.
8. ALL "OF EQUAL " SUBSTITUTIONS SHALL BE SUBMITTED TO AND
APPROVED BY THE CITY BUILDING OFFICIAL PRIOR TO INSTALLATION.
9. THE ISSUANCE OF A BUILDING PERMIT DOES NOT AUTHORIZE THE INSTALLATION OF MECHANICAL WORK,
SUCH AS PLUMBING, ELECTRICAL, HEATING REFRIGERATION, WHICH REQUIRES A SEPARATE PLUMBING,
ELECTRICAL, HEATING OR REFRIGERATION PERMIT.
10. ALL WORK SHALL BE DONE IN ACCORDANCE WITH HOME OWNERS ASSOCIATION GUIDELINES
CALIFORNIA ENERGY COMMISION (TITLE 24) REQM'TS.
I . ALL SWINGING DOORS AND WINDOWS OPENING TO THE EXTERIOR OR TO UNCONDITIONED
AREAS SUCH AS GARAGES, SHALL BE FULLY WEATHER-STRIPPED, GASKETED OR OTHERWISE
TREATED TO LIMIT INFILTRATION. ALL MANUFACTURED WINDOWS AND SLIDING GLA55 DOORS
SHALL MEET THE AIR INFILTRATION STANDARDS OF THE 1972 AMERICAN NATIONAL STANDARDS
INSTITUTE A.S.T.M. 283-73 WITH A PRESSURE DIFFERENTIAL OF 1.57 LBS. PER SQUARE FOOT
AND SHALL BE CERTIFIED AND LABELED.
2. UPON COMPLETION OF THE INSTALLATION OF INSULATION, A CARD CERTIFYING THAT THE
INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE REQUIREMENTS OF THESE
REGULATIONS SHALL BE COMPLETED BY THE INSULATION APPLICATOR AND BY THE BUILDER.
TF115 INSULATION COMPLIANCE CARD SHALL BE POSTED AT A CONSPICUOUS LOCATION WITHIN
THE DWELLING.
REFERENCE CODES
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES:
2010 - CALIFORNIA BUILDING CODE
2010 - CALIFORNIA MECHANICAL CODE
2010 - CALIFORNIA PLUMBING CODE
2
0 10 .CALIFORNIA=CECT I L CODE.
2010 - CALIFORNIA ENERGY CODE
AND ALL LOCAL CODES * ORDINANCES IN EFFECT AT THE PLACE
OF WORK
NOTE!
PROVIDE 120 VO CARBON RBON MONOXIDE A () AS REQUIRED.
ALARM(5) U I ED.
IN DWELLING UNITS AND SLEEPING UNITS WITHIN WHICH FUEL -BURNING APPLIANCES
ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES, AN APPROVED
CARBON MONOXIDE ALARM SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS:
I. ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE
IMMEDIATE VICINITY OF BEDROOMS.
2. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.
NEW GLB 3Ye" x 12"
GLULAM 24F- I .8E
CAMBER .43"
-SIMPSON 5T22 STRAP
EA. 51DE
NEW 4 x 4 POST
POST / BEAM DETAI L 1 2
2 SCALE: I"= P-0"
Ft
Z JLIUIIVV l7L.t%00 UUUIC
REAR ELEVATION 1 2 4 8
SCALE: 1/4"= I'-0"
EXIST. BEAM
EXIST. TILE ROOF
12
14
EXIST. CEMENT
PLASTER
EXIST. BUILT-UP ROOF
T-4"
NEW GLB 3Y 12"
GLULAM 24F-1.81
CAMBER .43"
PROPERTY LINE
16.60 50. FT.
U - FACTOR .5
FENESTRATION -FRONT
(NW)
17.5 50. Fr.
U - FACTOR'S
FENESTRATION - LEFT
(NE) t
17.5 50. FT.
U - FACTOR .5
FENESTRATION - LEFT
(NE)
7O0
23.G 50. FT.
U - FACTOR .5
FENESTRATION - LEFT
(NE)
CALLS MARIA
EXIST. GARAGE
18.5 50. FT.
O - FACTOR .5
FENESTRATION - RIGHT
EXIST. CEMENT R(5M
NEW 162" x 95.5" PLASTER 18.5 50, FT. 18.5 50. FT.
SLIDING GLA55' DOOR r FENESTRATION -LEFT FENESTRATION - RIGHT
(NE) (SM
13.7 50, FT.
U - FACTOR .5
. _
FENESTRATION ON FR
ONT CD
(NW) -TEMPERED
l O
OI SECTION 1 2 4 8 PROPEF:TY LINE`
PfR ERTY UNE • (o j
SCALE: 114"=11-011 Is
I- O EXIST. RESIDENCE
SEE FLOOR
CITY OF LA QUINTA
PLAN .THIS - .
_ SHEET _ -. _ -
- - -" BUILDING & SAFETY DEPT.
- )APPROVED
U %
BATH
O 107.5 50. rr.
U - FACTOR .51 FOR CONSTRUCTION
EXIST. RIDGE BEAM FENESTRATION - REAR
LIVING ROOM ME) - TEMPERED
- ` D, TE
NEW I G2" x 95.5"
SLIDING GLA55 DOOR I 'U - FACTOR 50. .51 REMOVE EXIST. 45.0 50. FT. I
P05T U - FACTOR .51
m " u FENESTRATION - LEFT FENESTRATION - RIGHT
NEW GLB 3YB x 12 (51Aq -TEMPERED
I (NE) - TEMPERED
GLULAM 24F- I .8E
a CAMBER .43" '
OUTLET TO BE OUTLET TO BE T.V. TO BE ( -11f
QpREMOVED REMOVED AIS ,REMOVED ( OVERHANG I U - FACTOR .5 I
YY I ' FENESTRATION - RIGHT
(5M - TEMPERED
NEW P05T NEW POST
27.4 50. FT, 2IFACTOR.5
4 S0. FT.
e e U- FACTOR .5 I MTKAT I I
A I FENCSTRATION -REAR (N NESTRATION -LEFT
EXIST. FLUOR FIXTURE .
EXIST ROOF I u FFACTOR.5 I
DINING ROOM FEI lE5TRATION - RIGHT R i Com+ j`% +
%I OVERHANG t (5
-7-r %
BEDROOM13'-103 "
a G. 50. FT. FEB U 2011
UL* I -0
FENE5TRATIO RIG
(5w) 16.0 50. FT.
I I U - FACTOR.
PROPERTY UNE (SE) T -REAR
I
I
I
I
51TE PLAN 2 4 8 1 G
Ir II EXISTING RESIDENCE I 2,280.00 SCALE: 1/8"= P-0" EXISTING
GARAGE 473.00
I TOTAL 2,753.00
----- -
A.P.N. # 773-340-01 5
NOTEI
KITCHEN LEGAL DESCRIPTION
ALL EX15TING ALUMINUM DOORS WINDOWS SHALL BE REPLACED WITH
LOT 15 OF TRACT # 1449G- I IN THE CITY OF LA QUINTA, NEW RETROFIT ALUMINUM DOORS t WINDOWS
'000NTY OF RIVERSIDE, STATE OF CALIFORNIA AS PER MAP
RECORDED IN BOOK 119, PAGES 9 THROUGH 15 INCLUSIVE
OF MAPS, AND AS AMENDED BY CERTIFICATE OF CORRECTION
RECORDED AUGUST 1 1, 1983 AS INSTRUMENT # 162772,
OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER
FLOOR PLAN 1 2 4 _8 OF SAID COUNTY.
SCALE: 114"= P-0"
I i
m
■
N
U
M
LU
O O
=
W
8
z
E
p
N
Q
WN
Q
*0
i.L/
40=
OLu
U
p
77
rn
_
d
CQ
Ea
oc
800
t
a
c
13.7 50, FT.
U - FACTOR .5
. _
FENESTRATION ON FR
ONT CD
(NW) -TEMPERED
l O
OI SECTION 1 2 4 8 PROPEF:TY LINE`
PfR ERTY UNE • (o j
SCALE: 114"=11-011 Is
I- O EXIST. RESIDENCE
SEE FLOOR
CITY OF LA QUINTA
PLAN .THIS - .
_ SHEET _ -. _ -
- - -" BUILDING & SAFETY DEPT.
- )APPROVED
U %
BATH
O 107.5 50. rr.
U - FACTOR .51 FOR CONSTRUCTION
EXIST. RIDGE BEAM FENESTRATION - REAR
LIVING ROOM ME) - TEMPERED
- ` D, TE
NEW I G2" x 95.5"
SLIDING GLA55 DOOR I 'U - FACTOR 50. .51 REMOVE EXIST. 45.0 50. FT. I
P05T U - FACTOR .51
m " u FENESTRATION - LEFT FENESTRATION - RIGHT
NEW GLB 3YB x 12 (51Aq -TEMPERED
I (NE) - TEMPERED
GLULAM 24F- I .8E
a CAMBER .43" '
OUTLET TO BE OUTLET TO BE T.V. TO BE ( -11f
QpREMOVED REMOVED AIS ,REMOVED ( OVERHANG I U - FACTOR .5 I
YY I ' FENESTRATION - RIGHT
(5M - TEMPERED
NEW P05T NEW POST
27.4 50. FT, 2IFACTOR.5
4 S0. FT.
e e U- FACTOR .5 I MTKAT I I
A I FENCSTRATION -REAR (N NESTRATION -LEFT
EXIST. FLUOR FIXTURE .
EXIST ROOF I u FFACTOR.5 I
DINING ROOM FEI lE5TRATION - RIGHT R i Com+ j`% +
%I OVERHANG t (5
-7-r %
BEDROOM13'-103 "
a G. 50. FT. FEB U 2011
UL* I -0
FENE5TRATIO RIG
(5w) 16.0 50. FT.
I I U - FACTOR.
PROPERTY UNE (SE) T -REAR
I
I
I
I
51TE PLAN 2 4 8 1 G
Ir II EXISTING RESIDENCE I 2,280.00 SCALE: 1/8"= P-0" EXISTING
GARAGE 473.00
I TOTAL 2,753.00
----- -
A.P.N. # 773-340-01 5
NOTEI
KITCHEN LEGAL DESCRIPTION
ALL EX15TING ALUMINUM DOORS WINDOWS SHALL BE REPLACED WITH
LOT 15 OF TRACT # 1449G- I IN THE CITY OF LA QUINTA, NEW RETROFIT ALUMINUM DOORS t WINDOWS
'000NTY OF RIVERSIDE, STATE OF CALIFORNIA AS PER MAP
RECORDED IN BOOK 119, PAGES 9 THROUGH 15 INCLUSIVE
OF MAPS, AND AS AMENDED BY CERTIFICATE OF CORRECTION
RECORDED AUGUST 1 1, 1983 AS INSTRUMENT # 162772,
OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER
FLOOR PLAN 1 2 4 _8 OF SAID COUNTY.
SCALE: 114"= P-0"
I i
-J
D AROh'i
J Kent
* No. C 8819
.A REN. 05/31
NOT VALID WITHOUT WET INI
SIGNATURE
date: 2/2/2012 LM
print date:
job number:
sheet no.
A-
m
N
Q
U
LU
•
o
U
IQ -
z
z
o
p
Q
Q
WN
Q
(nn/
i.L/
W
J
OLu
U
p
77
co
LUW
Q
CQ
'Ln'
-J
D AROh'i
J Kent
* No. C 8819
.A REN. 05/31
NOT VALID WITHOUT WET INI
SIGNATURE
date: 2/2/2012 LM
print date:
job number:
sheet no.
A-