Loading...
SFD (10578)51995 Avenida Martinez 10578 4 P.O. BOX 1504 V_- No. 10578 Building 78-105 CALLE ESTADO Address 51--995 HartineZ LA QUINTA, CALIFORNIA 92253 //)/;L— Owner Ishmeal Coronet BUILDING: TYPE CONST. OCC. GRP.: Mailing Address 51-755 Velasco CityLZip Tel. a Quinta 92253 564--0174 Coronet Construction Aooress I 51-970 Eisenhower Drive City lZip I Tela State Lic. City & Classif. 634981 B Lic. # Arch., Engr., Designer Address I Tel. City( Zip ( State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirdn that I a2Aicensed unde provisions of Chapter 9 (commencing with Section 7000) of Diivvision 3 of th Business and Professions Code, and my license is in full/force and effect. C l / 4-,% / d :, /i i1 ! Z SIGNATURE r - DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Buslness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to lila a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permff subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or Improve for the purpose of sale.) . O I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company 1, Q4;Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars (3100) valuation or less.) I certify that in the performance of th? work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., It, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3 09 7, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip A.P. Number Legal Description_ Project Description 5PD r;y.Yi Sq. Ft. 1162 Size No. Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit does not include block 11iall or pool Estimated Valuation 87,866.50 7j866.50 PERMIT AMOUNT Plan Chk. Dep. 250.00 Plan Chk. Bal. 253.16 Const. 585.50 Mech. 55.50 Electrical • 125.09 Plumbing 157.50 S.M.I. 8.80 Grading 20.00 Driveway Enc. 20.00 Infrastructure 1938.75 TOTAL 3314.30 3164.30 REMARKS sti L:AaH 3 .fi1fFit 1 3.t • ). i, ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES' IST FL. SO. FT. ® $ 2ND FL. SQ. FT. POR. SO. FT. ® GAR. SO. FT. ® CARP. SQ. FT. WALL SO. FT. ® SQ FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES FORMSS WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) • ETER LOOP GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPJEQUIP. LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPE RM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB FINAL INSP. 2 J SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1% c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ic HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. ING HEATING (ROUGH) STORAGE TANK FORMSS EWER OUGH IRING. DUCTWORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) • ETER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE 3 Q t GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. x$ _$ LUMBER GR. FINAL INSP. 2 J FRAMING S0j, F FINAL INSP '&—`plus ^- ROOFING Z3 ijA l J , r'S .; rt•3 f p ! q v ! ! [, W 3 A - a ! t ` y b s /c h T (/1 thJ C Pohl . V REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL ZING m"' ,mv A.- 8 INSULATION/SOUND FINISH GRADING FINAL INSPECTIO crI q 3 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 2/11/92 No. 11180 Type of Permit I La Quinta Permit # Owner Name Ishmeal Coronel Log # Jl o No. Street e4 - I w/ city La Quinta zip 92253 Study Area 115 APN # Tract # Lot # Square Footage 1531 / Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.58 X 11.531 or $ 2,418.98 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Zeke Coronel Name on the check By James E. Lively Assistant Superintendent, Business Services Fee collected /exempted by Vickie J. Durrett Telephone 564-0174 Payment Received Signature C%c.2A, = Check No. 1011 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting Of R , CALVIN C. KAMINSKAS i DAN RILEY ' '' ° e Sealer, Weights & Measures Assislanl Commissioner p (714) 275-3030 (714)275-3000 OFFICE OF AGRICULTURAL COMMISSIONER JAMES O. WALLACE, Commissioner 83-612 Avenue 45 Suite 7. Indio,. CA 92201 (619) 342-8291 DA'I'S—/ r7 CASE NO. DEVELOPER'S NAME. ADDRESS: I r C S e✓1ha _i> - o. eoX 12 _26,g TE1,EP11ONE: ( ) Sb y t>±4 '7 o C Vv Dear Developer: After reviewing your landscaping plans, all plant material listed is not in violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material listed, this office must be notified immediately. Thank you for protecting and "preserving the Coachella Valley's pest -free environment. Agricult Commissioner's Office cc: Indio and Riverside 4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92501 — FAX (714) 275.3012 Iff 4* I I&I At , of On* ?'f l j g Tit of 14d (Quinta 11U*tb*n znd S fet iui siun This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building constrLction or use. For the following: BUILDING ADDRESS 51-995 Martinez Use Classification Sinqle Family DWellin4 Bldg. Permit No. 10578 Group R3 Type Construction VN Fire Zone Use Zone SR Owner of Building Coronel Construction Address P.17_ Raw 1238 city La Quinta, CA 92253 By. Lonnie Day. -7;- , ? Dote: June 2, 1993 Building Official . POST IN A CONSPICUOUS PLACE JOB SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE SCALE PRODUCT Wc.GOM MM. 01471. ToOldff MOM TOLL FREE I -MM -M C ..... .,.NF rn SHEET NO, C^Lovm,mBY_ o^,,__—__—__ __ SCALP MI; m: L% 1."w"+41,. w4 71 To C! I I F*.°".-M ~» I-- -7= SHEET or -- CALCULATED BY CIIECKED BY SCALE VAI E .. .. .... .. .. . . ..... ....... .. j . . ..... .... . ... .. .... I i i ' i 1 j , ...... ..... ... .... 44A lII ; 3 /2 .3/a 1 .fi d =.'ass i 00 le . j. ' :_ 280 .. . ....... ... .... ... ...... .. .... ... ..... .... ...... ...... . ... .... lip - 4 1/ zn. 04, ..... . . 1..... ..... ...... ... ..... ... .... .. . ... .... . .. . .. ... . ......... ...... . .... .... ... t* 4x I w -I 1q ... ...... .. .. GILL'... 1,7-s4 =Z -7-7'If. 5-1. LL 77- ... .. .... .... . ..... . ..... ........ . 1,,0.1- r Q:l TOU - W I k1M w PAGE : PROJECT SUBJECT DATE : BY : T I M B E R B E A M D E S I G N ------------------------------------------ Beam Mark >>> 1 2&4 3 5 6 CENTER SPAN ft ; 16.00 12.00 9.00 10.00 6.00 W -DL #/ft; 153 353 96 196 352 W -LL #/ft; 112 280 64 48 208 Wp-DL #/ft; 0 0 0 0 0 Wp-LL #/ft; 0 0 0 0 0 X -Left ft ; 0.00 0.00 0.00 0.00 0.00 X -Right ft ; 0.00 0.00 0.00 0.00 0.00 P-1 DL lbs ; 0 0 0 2,736 0 P-1 LL lbs ; 0 0 0 2,048 0 X-1 ft ; 0.0 0.0 0.0 6.5 0.0 P-2 DL lbs ; 0 0 0 0 0 P-2 LL lbs ; 0 0 0 0 0 X-2 ft ; 0.0 0.0 0.0 0.0 0.0 P-3 DL lbs ; 0 0 0 0 0 P-3 LL lbs ; 0 0 0 0 0 X-3 ft ; 0.0 0.0 0.0 0.0 0.0 CANT. SPAN ft ; 0.00 0.00 0.00 0.00 0.00 Wp-DL #/ft; 0 0 0 0 0 Wp-LL #/ft; 0 0 0 0 0 X -Left ft ; 0.00 0.00 0.00 0.00 0.00 X -Right ft ; 0.00 0.00 0.00 0.00 0.00 P-1 DL .lbs ; 0 0 0 0 0 P-1 LL lbs ; 0 0 0 0 0 X-1 ft ; 0.0 0.0 0.0 0.0 0.0 P-2 DL lbs ; 0 0 0 0 0 P-2 LL lbs ; 0 0 0 0 0 X-2 ft ; 0.0 0.0 0.0 0.0 0.0 > Fb psi ; 1,500 1,500 1,500 1,500 1,500 > Fv psi ; 95 95 95 95 95 > E psi; 1.8E+06 1.8E+06 1.8E+06 1.8E+06 1.8E+06 > L.D.F. ; 1.25 1.25 1.25 1.25 1.25 > BEAM WIDTH i in ; 3.5 3.5 3.5 3.5 3.5. > BEAM DEPTH in ; 13.50 13.50 5.50 15.50 5.50 POS. MOM. in -k; 101.8 136.7 19.4 161.3 30.2 NEG. MOM in -k; 0,0 0.0 0.0 0.0 0.0 t J . 6 {.' j PAGE PROJECT SUBJECT DATE BY : REACTIONS 11 Left DL lbs ; 1,224 2,118 432 1,938 1,056 i LL lbs ; 896 1,680 288 957 624 Right DL lbs ; 1,224 2,118 432 2,758 1,056 r LL lbs ; 896 1,680 288 1,571 624 ----------------- STRESSES ; is Cf- Depth ; 0.987 0.987 1.000 0.972 1.000 4 'Fb: Allow psi ; 1,851 1,851 1,875 1,822 1,875 • Fb: Actual psi ; , 957 1,286 1,102 1,151 1,714 Fv: Allow psi , ; 118.8 118.8 118.8 118.8 118.8 Fv: Actual psi ; 57.84 97.96 50.39 111.00 110.91 1 DEFLECTIONS - - - - - - ;----------;--------;--------;--------;------- CENTER SPAN > X -Dist. ft ; 8.0 6.0 4.5 5.0 3.0 DL Defl in ; 0.175 0.128 0.162 0.067 0.118 L / Defl. ; 1,099 1,129 666 1,796 613 LL Defl in ; 0.128 0.101 0.108 0.039 0.069 L / Defl. ; 1,502 .1,424 998 3,104 1,037 'r L/Tot Defl. ; 635 630 399 1,138 385 1 }, CANT. SPAN r. > X -Dist. ft ; 0.00 0.00 0.00 0.00 0.00 t , DL Defl. in 0.000 0.000 0.000 0.000 0.000 "i LL Defl. in ; 0.000 0.000 0.000 0.000 0.000 e = c%' 1 t 1 j^ ggr t''Ix' • ' ^t t y I PROJECT : SUBJECT : DATE T I M B E R B ------------------------------------------ E A M D E S I G N Beam Mark >>> 7 CENTER SPAN ft ; 19.00 W -DL #/ft; 324 W -LL #/ft; 256 Wp-DL #/ft; 0 Wp-LL #/ft; 0 X -Left ft ; 0.00 X -Right ft ; 0.00 P-1 DL lbs ; 0 P-1 LL lbs ; 0 X-1 ft ; 0.0 P-2' DL lbs ; 0 P-2 LL lbs ; 0 X-2 ft ; 0.0 P-3 DL lbs ; 0 P-3 LL lbs ; 0 X-3 ft ; 0.0 CANT. SPAN ft ; 0.00 Wp-DL #/ft; 0 Wp-LL #/ft; 0 X -Left ft ; 0.00 X -Right ft ; 0.00 P-1 DL lbs ; 0 P-1 LL lbs ; 0 X-1 ft ; 0.0 P-2 DL lbs ; 0 P-2 LL lbs ; 0 X-2 ft ; 0.0 > Fb psi ; 1,300 > Fv psi ; 85 > E psi ; 1.6E+06 > L.D.F. ; 1.25 > BEAM WIDTH in ; 5.5 > BEAM DEPTH in ; 14.68 POS. MOM. in -k; 314.1 NEG. MOM. in -k; 0.0 BY :. 0 REACTIONS Left : DL lbs ; 3,078 LL lbs ; 2,432 Right : DL lbs ; 3,078 LL lbs ; 2,432 STRESSES Cf- Depth ; 0.978 Fb: Allow psi ; 1,589 Fb: Actual psi ; 1,591 Fv: Allow psi ; 106.3 Fv: Actual psi ; 89.22 DEFLECTIONS CENTER SPAN > X -Dist. ft ; 9.5 DL Deft in ; 0.410 L / Defl. ; 556 LL Defl in ; 0.324 L / Defl. ; 704 L/Tot Defl. ; 311 CANT. SPAN > X -Dist. ft ; 0.00 DL Defl. in ; 0.000 LL Defl. --------------------------- --------------------------- in ; 0.000 ®Hlsam> = i"JA. ....... .... .. . ........... I ......... . .. ....... ......... ................... ......... .......... .......... ......... .......... . ..... .. ........... ........ .......... ..... . .. I * **"*'*'* . . . .... ........ .......... I . ........... .......... ... . ......... . jj msffj • .......... ........... ...... . .........I c l ......... ..... ..... ..... .......... :10 - Tlv3s "—An 03)133ti0 An aawmivo -ON la3liS nor ........... ......... . ........... ®Hlsam> = i"JA. ....... .... .. . ........... I ......... . .. ....... ......... ................... ......... .......... .......... ......... .......... . ..... .. ........... ........ .......... ..... . .. I * **"*'*'* . . . .... ........ .......... I . ........... .......... ... . ......... . jj msffj • .......... ........... ...... . .........I c l ......... ..... ..... ..... .......... :10 - Tlv3s "—An 03)133ti0 An aawmivo -ON la3liS nor R T I T L E G 4 G ENERG~('A CON SEF:',.A-F I ON S-I-ANDARDG [RES I DENT I At— COMPL I r^,NCE POFtTFOL I O Prepared for: Proj ec t : Prepared by: P A T K E L L t•Y E L E C T R I C HEATING °c AIR CONDITIONING 32-192 Sierra Avenue Indio,. CA.92201 (:619) 347-5233 STATE LIC. 0.376505 ' 13 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... LUCAS CORONEL Date........ 01/03/92 Project Address........ LA QUINTA CA --------------------- Documentation Author... CATHY KELLEY ; Building Permit # Company ................ CATHY KELLEY Telephone. .............. 347-5233 ; Plan Check / Date Compliance Method...... MICROCHECK Field. Check/ Date Climate Zone........... 15--------------------- MICROCHECK v1.00 File-FIRSTRUN Program -FORM C -2R User -CATHY KELLEY Run -Typical House ------------------------------------ MICROCHECK ENERGY USE SUMMARY = ----------------------------- Energy Use (kBtu/sf-yr ) ----------------------- Space Heating.......... Space Cooling.......... Water Heating.......... GENERAL INFORMATION Conditioned Floor Area..... Building Type..... ....... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area........... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... Total Standard Proposed Compliance - Design ---------- Design ---------- Margin = ---------- - 6.85 5.29 1.56 = 45.05 43.21 1.84 - 11.97 -------- 11.97 -------- 0.00 = -------- 63.87 60.47 3.40 = *** Building complies 1562 sf Single Family Detached Front Facing 180 deg ( S ) 1 1 FullYear Slab On Grade 1 12897 cf 490 sf 490 sf 12.2 % of FA 8.3 ft BUILDING ZONE INFORMATION Floor Cond- Area Zone Type itioned (sf) -------------- ------- --------- HOUSE Residence Yes 1562 Vent Special Volume # of Thermostat Height Vent Area (cf ) Units Type (ft) (sf) --------- ----------------- ------ --------- 12897 1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... LUCAS CORONEL Date........ 01/03/92 MICROCHECK v1.00 File-FIRSTRUN Program -FORM C -2R User -CATHY KELLEY Run -Typical House ' OPAQUE SURFACES Area U- Insul Act Solar Location/ Form 3R Surface ------------ (sf) ------ value R-val Azmth Tilt Gains Comments ----- ----- Reference HOUSE ----- ---- ----- ---------------- ------------ 1 Wall 339 0.090 R-11 0 90 Yes 2 Wall 92 0.090 R-11 90 90 Yes 3 Wall 415 0.090 R-11 180 90 Yes 4 Wall 207 0.090 R-11 270 90 Yes 5 Roof 1562 0.030 R-38 0 0 Yes attic 6,Door50, 0.330 R-0 0 90 Yes PERIMETER ---------------- LOSSES Length F2 Insul Surface ------------ (ft) ------ Factor R-val Location/Comments HOUSE --------------- ---------------------- 1 S1abEdge 143 0.900 R-0 exp: to out GLAZING SURFACES ---------------- Vent SC Interior SC Area # of Frame Open U- Act Glass Shade Gls+ Surface ----------- (sf) Panes Type Type value Azmth Tilt Only ----- ------------- ------ ----- ----- ---- ----- Type Shade HOUSE ---------- ----- 1 Window 28 2 Metal Slider 0.65 0 90 0.77 drapes 0.66 2 Window 28 2 Metal Slider 0.65 90 90 0.77 drapes 0.66 3 Window 85 2 Metal Slider 0.65 180 90 0.77 drapes 0.66 4.Window 49 2 Metal Slider 0.65 270 90 0.77 drapes 0.66 OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface ----------- (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght ----- ----- ----- ---- Ext Dpth Hght HOUSE ---- ---- ---- ---- ---- --=- ---- ---- ---- 3 Window 85 5.0 0 3.0 0.5 0 0 0 0 0 0 0 0 EXTERIOR ---------------- SHADING ---------------- Area Shading SC of Surface ------------ (sf) ------ Type Ext Shade --------------- HOUSE --------- 2 Window 28 Sun Screen 0.36 4 Window 49 Sun Screen 0.36 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... LUCAS CORONEL Date........ 01/03/92 MICROCHECK v1.00 File-FIRSTRUN Program -FORM C -2R , User -CATHY KELLEY Run -Typical House ' ------------------------------------------------------------------------------- THERMAL MASS Area Mass Type ( sf ) --------------- ------ HOUSE 1 S1abOnGrade 490 HVAC SYSTEMS Thick Heat Conduct- Surface (in) Cap ivity R -value Location/Comments ----- ----- -------- -------- -------------------------- 3.5 28.0 0.98 R-0 kitchen & entry WATER HEATING SYSTEMS --------------------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ None Minimum Duct Duct Duct System Type ---------------- Efficiency ------------ Location ------------- R -value ------- Efficiency ---------- HOUSE Gas 0.750 SE Attic R-4 0.816 A/C 9.00 SEER Attic R-4 0.803 WATER HEATING SYSTEMS --------------------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... LUCAS CORONEL Date........ 01/03/92 Project Address........ LA QUINTA CA _____________________ Documentation Author... CATHY KELLEY ; Building Permit # Company................ CATHY KELLEY Telephone ......:....... 347-5233 ; Plan Check/ Date Compliance Method...... MICROCHECK ; Field Check/ Date Climate Zone........... 15 --------------------- MICROCHECK v1.00 File-FIRSTRUN Program -FORM CF -1R N User -CATHY KELLEY Run -Typical House ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... Building Type .............. Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... Infiltration Control....... 1562 sf Single Family Detached Front Facing 180 deg ( S ) 1 1 Slab On Grade Standard BUILDING SHELL INSULATION Component Insul Type R -value Location/Comments ----------------- ---------------------------------------- Wall R-11 Roof R-38 attic Door R-0 S1abEdge R-0 exp: to out GLAZING Glazing Overhangs/ Framing Area Orientation Type None (sf) Window Back ( N ) 28 Window Right ( E ) 28 Window Front ( S ) 85 :'Window Left ( W ) 49 (THERMAL MASS 'Type S1abOnGrade # of Interior Panes Shading 2 drapes 2 drapes 2 drapes 2 drapes Area Thickness (sf) (in) ------ --------- 490 3.5 Hard Surfaced/ Exposed -------------- Yes Exterior Overhangs/ Framing Shading Side Fins Type None None Metal None None Metal None Yes Metal None None Metal Location/Comments ------------------------ kitchen & entry CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... LUCAS CORONEL Date........ 01/03/92 MICROCHECK v1.00 File-FIRSTRUN Program -FORM CF -1R User -CATHY KELLEY Run -Typical House ' ------------------------------------------------------------------------------- ASSUMED HVAC SYSTEMS Assumed Duct Duct Assumed System Efficiency Location R -value --------------- ------------ ------------- ------- Gas 0.750 SE Attic R-4 A/C 9.00 SEER Attic R-4 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency (Btuh) (or approved equal) ---------------' ----------- -------- --------------------------------- Heating 73.3 75000 AIRQUEST NAGH001 RC Cooling 9 45000 AIRGUEST CA4048VKC Cooling Coil SAME CEC Maximum Output for Gas Central Furnaces= WATER HEATING SYSTEMS Btuh Tank Capacity Manufacturer and Model # Energy System Type (gal) (or approved equal) Credits ------------------------------------------------------------------------ Meets CEC Minimum None SPECIAL FEATURES/REMARKS ------------------------ None CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... LUCAS CORONEL Date........ 01/03/92 ------------------------------------------------------------------------------- MICROCHECK v1.00 File-FIRSTRUN Program -FORM CF -1R User -CATHY KELLEY Run -Typical House ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by t'he individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER OWNER Name.... LUCAS CORONEL Name.... LUCAS CORONEL Company. Company. Address. Address. Phone... Phone... License. Signed Signed (date) (date) DOCUMENTATION AUTHOR ENFORCEMENT AGENCY Name.... CATHY KELLEY Name.... Company. CATHY KELLEY Title... Address. 82-192 SIERRA Agency.. INDIO, CA 92201 Phone... 347-5233 Phone... Signed Signed (date) (date) FORMATTED INPUT Page 1 FORMAT MICROCHECK v1.00 File-FIRSTRUN Program -FORMAT Run -Typical House Project -LUCAS CORONEL Date-01/03/92 ------------------------------------------------------------------------------- Input file 'FIRSTRUN' last edited on 01/03/92 GENERAL INFORMATION ------------------- ------------------- RUN FEATURES . 51► 1> RUN TITLE (25 char) ............................. Typical House 2> PROJECT TITLE (25 char) ......................... LUCAS CORONEL 3> DOCUMENTATION AUTHOR (25 char) .................. CATHY KELLEY BUILDING 4> 4> BUILDING TYPE ................................... Single 5> ACTUAL FRONT ORIENTATION (deg, 0=N,90=E,180=S) .. 180 6> AZIMUTH TYPE .................................... Actual 7> NUMBER OF STORIES (1 or more) ................... 1 8> DESIGN HEAT LOSS (Btuh) ......................... None 9> CEC CLIMATE ZONE ................................ 15 CALCULATIONS AND REPORTS 1> COMPLIANCE CALCULATIONS ......................... Yes 2> STANDARD DESIGN INPUT DATA ...................... NoSave 3> SPACE CONDITIONING CALCULATIONS ...,.............. Yes 4> WATER HEATING CALCULATIONS ...................... Yes 6> PRINT CF -1R COMPLIANCE REPORT. ................... Yes 7> PRINT C -2R COMPLIANCE REPORT .................... Yes 8> PRINT FORM 3R COMPLIANCE REPORT ................. Yes 9> PRINT INPUT DATA ................................. Yes BUILDING ZONES -------------- -------------- ZONE INFORMATION #> NUMBER OF ZONES (5 maximum) ..................... 1 HEAT HEATING DUCT ZONE FLOOR EFFIC- # OF DUCT ZONE ZONE COND- AREA VOLUME DWELL THERMOSTAT NAME TYPE ITIONED (sf ) ( cuft ) UNITS TYPE ---1---- -----2----=- ---3--- ----4---- ----5---- --6-- -----7------ 1> HOUSE Residence Yes 1562 12897 1.0 Setback HEATING SYSTEMS COOLING SYSTEMS HEATING SEASONAL HEAT HEATING DUCT ZONE SYSTEM EFFIC- PUMP DUCT INSUL NAME TYPE IENCY HSPF LOCATION R -VALUE ---1---- ----2---- ---3---- ---4---- ------5------ ---6---- 1> HOUSE Gas 0.75 0 Attic 4 COOLING SYSTEMS FORMATTED INPUT Page 2 FORMAT MICROCHECK v1.00 File-FIRSTRUN Program -FORMAT Run -Typical House Proj6ct-LUCAS CORONEL Date -01/03/92 ------------------------------------------------------------------------------- COOLING COOLING DUCT ZONE SYSTEM SEASONAL DUCT INSUL NAME TYPE EER LOCATION R -VALUE ---1---- ----2---- ----3---- ------4------ ---5---- 1> HOUSE A/C 9 Attic 4 NATURAL VENTILATION SYSTEMS OPAQUE SURFACES --------------- #> NUMBER OF INLET HEIGHT ZONE VENTILATION AREA DIFF NAME TYPE PER ZONE (ft) ---1--__ __---2------ ---- 3-.--- ---4--- 1> HOUSE Standard 0 2.0 OPAQUE SURFACES --------------- #> NUMBER OF SURFACES (50 maximum) ................. 10 INSUL PERIMETER LENGTH FORM 3R INSUL DEPTH SURFACE AREA U- INSUL (ft) FACTOR SLR LOCATION/ ASSEMBLY ZONE TYPE (sf) VALUE R-VAL AZM TILT GAIN COMMENTS REFERENCE NAME 0.90 ---1---- --2--- --3-- --4-- -5- -6-- -7-- ------8------ -----9------ -10-- 1> Wall 339 0.090 11 0 Vert Yes exp: to gar HOUSE HOUSE 2> Wall 92 0.090 it 90 Vert Yes HOUSE 3> Wall 415 0.090 11 180 Vert Yes HOUSE 4> Wall 207 0.090 11 270 Vert Yes HOUSE 5> Wall 0 0.065 19 0 Vert Yes corner HOUSE 6> Roof 0 0.035 38 0 30 Yes vaulted HOUSE 7> Roof 1562 0.030 38 0 0 Yes attic HOUSE 8> Door 50 0.330 0 0 Vert Yes HOUSE 9> Floor 0 0.037 19 0 0 No to crawlspace HOUSE 10> FloorExt 0 0.049 19 0 0 No to garage HOUSE PERIMETER LOSSES #> NUMBER OF SURFACES (50 maximum) ................. 4 INSUL PERIMETER LENGTH F2 INSUL DEPTH LOCATION/ ZONE TYPE (ft) FACTOR R-VAL (in) COMMENTS NAME ----1---- --2--- ---3---- ---4--- --5--- -------6------- ---7---- 1> SlabEdge 143 0.90 0 0 exp: to out HOUSE 2> SlabEdge 0 0.72 0 0 cvr: to out HOUSE 3> SlabEdge 0 0.55 0 0 exp: to gar HOUSE 4> SlabEdge 0 0.50 0 0 cvr: to gar HOUSE GLAZINGS GLAZING SURFACES #> NUMBER OF SURFACES (50 maximum) ................. 9 FORMATTED INPUT EXTERIOR SC GLAZING SHADE EXT Page 3 TYPE FORMAT SHADE MICROCHECK v1.00 File-FIRSTRUN --3-- 1> Program -FORMAT None 1.0 2> Window Sun Screen ------------------------------------------------------------------------------- Run -Typical Window House Project -LUCAS CORONEL Date -01/03/92 5> Window Sun Screen 0.36 6> Window Sun Screen 0.36 VENT Door None 1.0 SC INTERIOR Tint SC 9> Skylight GLAZING AREA # OF FRAME OPEN U- GLS SHADE GLS+ ZONE TYPE (sf) PANE TYPE . TYPE VAL AZM TILT ONLY DESCRIP SHDE NAME ---1---- --2-- -3-- --4--- --5--- -6-- -7- -8-- -9-- ----10---- -11- -12-- 1> Window 28 2 Metal Slider 0.65 0 Vert 0.77 drapes 0.66 HOUSE 2> Window 28 2 Metal Slider 0.65 90 Vert 0.77 drapes 0.66 HOUSE 3> Window 0 2 Metal Slider 0.65 90 Vert 0.77 drapes 0.66 HOUSE 4> Window 85 2 Metal Slider 0.65 180 Vert 0.77 drapes 0.66 HOUSE 5> Window 49 2 Metal Slider 0.65 270 Vert 0.77 drapes 0.66 HOUSE 6> Window 0 1 Metal Slider 1.10 45 Vert 0.88 drapes 0.80 HOUSE 7> Door 0 1 None Hinged 1.10 270 Vert 1.00 drapes 0.91 HOUSE 8> Skylight 0 1 Metal Slider 1.03 270 23 0.88 None 0.88 HOUSE 9> Skylight 0 2 Metal Slider 0.64 0 Horz 0.77 None 0.77 HOUSE OVERHANGS AND SIDE FINS OVERH OVERH LEFT LEFT LEFT RGHT RGHT RGHT GLAZING WIND WIND OVERH OVERH LEFT RGHT FIN FIN FIN FIN FIN FIN TYPE HGHT WDTH DPTH HGHT EXT EXT EXT DPTH HGHT EXT DPTH HGHT ---1---- --2-- --3-- --4-- --5-- --6-- --7-- -8-- -9-- -10- -11- -12- -13- 1> Window 0 0 0 0 0 0 0 0 0 0 0 0 2> Window 0 0 0 0 0 0 0 0 0 0 0 0 3> Window 4.0 0 8.0 0.5 0 0 0 0 0 0 0 0 4> Window 5.0 0 3.0 0.5 0 0 0 0 0 0 0 0 5> Window 0 0 0 0 0 0 0 0 0 0 0 0 6> Window 0 0 0 0 0 0 0 0 0 0 0 0 7> Door 0 0 0 0 0 0 0 0 0 0 0 0 8> Skylight 0 0 0 0 0 0 0 0 0 0 0 0 9> Skylight 0 0 0 0 0 0 0 0 0 0 0 0 EXTERIOR SHADING THERMAL MASS #> NUMBER OF SURFACES (10 maximum) 4 EXTERIOR SC GLAZING SHADE EXT TYPE DESCRIPTION SHADE ---1---- -------2------- --3-- 1> Window None 1.0 2> Window Sun Screen 0.36 3> Window None 1.0 4> Window None 1.0 5> Window Sun Screen 0.36 6> Window Sun Screen 0.36 7> Door None 1.0 8> Skylight Tint 0.25 9> Skylight Tint 0.25 THERMAL MASS #> NUMBER OF SURFACES (10 maximum) 4 FORMATTED INPUT AND PHONES .................... Yes PROJECT HEATING SYSTEM Page 4 FORMAT LA QUINTA CA MICROCHECK v1.00 File-FIRSTRUN Program -FORMAT DESIGNER ------------------------------------------------------------------------------- Run -Typical House Project -LUCAS CORONEL• Date -01/03/92 LUCAS CORONEL 4> FIRM (25 char) .................................. COOLING SYSTEM 5> ADDRESS (25 char) ............................... CON- SUR - char) ........................ 5> 7> PHONE (25 char) ................................. (25 char) .............. AREA THICK HEAT DUCT- FACE LOCATION/ ZONE 9> CONTACT (25 char) MASS TYPE (sf) (in) CAP IVITY R-VAL COMMENTS NAME 12> CITY STATE ZIP -----1------ --2-- --3-- -4-- --5-- --6-- ---------7---------- --8-- 1> S1abOnGrade 490 3.5 28 0.98 0 kitchen & entry HOUSE 2> S1abOnGrade 0 3.5 28 0.98 2.0 typical HOUSE 3> InteriorHorz 0 1.0 24 0.67 0 tile HOUSE 4> InteriorVert 0 4.0 21 0.59 0 Fireplace HOUSE WATER HEATING WATER HEATER SYSTEM #> NUMBER OF SYSTEMS (1 maximum) ................... 1 SYSTEM TYPE ---1---- 1> Standard NOTES ADDRESSES AND PHONES #> DISPLAY ADDRESSES AND PHONES .................... Yes PROJECT HEATING SYSTEM 1> ADDRESS (25 char) ............................... LA QUINTA CA 2> CITY (25 char) .................................. AIRQUEST NAGH001 RC 2> DESIGNER (10 char) ................ 73.3 3> CONTACT (25 char) ............................... LUCAS CORONEL 4> FIRM (25 char) .................................. COOLING SYSTEM 5> ADDRESS (25 char) ............................... COMPRESSOR MAKE & MODEL 6> CITY STATE ZIP (25 char) ........................ 5> 7> PHONE (25 char) ................................. (25 char) .............. SAME 8> CALIF LIC NUMBER (25 char) ....................... OWNER 9> CONTACT (25 char) ............................... LUCAS CORONEL 10> FIRM (25 char) ................................. 11> ADDRESS (25 char) .............................. 12> CITY STATE ZIP (25 char) ..................... 13> PHONE (25 char) ................................ HVAC EQUIPMENT NOTES #> DISPLAY HVAC EQUIPMENT NOTES .................... Yes HEATING SYSTEM 1> MAKE & MODEL NUMBER (25 char) ................... AIRQUEST NAGH001 RC 2> ACTUAL EFFICIENCY/HSPF (10 char) ................ 73.3 3> ACTUAL OUTPUT CAPACITY (10 char) ................ 75000 COOLING SYSTEM 4> COMPRESSOR MAKE & MODEL NUMBER (25 char) ........ AIRQUEST CA4048VKC 5> COIL MAKE & MODEL NUMBER (25 char) .............. SAME c.7 i n%. i vnL ..;pLl_fN % .Lv %.,i is i J . . . . . . . . . . . . . . . . . . . . . 7 FORMATTED INPUT Page 5 FORMAT MICROCHECK v1.00 File-FIRSTRUN Program -FORMAT Run -Typical House Project -LUCAS CORONEL Date-01/03/92 ------------------------------------------------------------------------------- 7> ACTUAL OUTPUT CAPACITY (10 char) ..:............. 45000 SPECIAL FEATURE NOTES #> NUMBER OF NOTES (50 maximum) .................... 1 SPECIAL FEATURE NOTES -------------------------------- 1 -------------------------------- 1> -------------------------------1-------------------------------- 1> None Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildings subject'to the Standards must contain these measures regardless of the -compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Building Envelope Measures * §2-5352(a): Minimum ceiling insulation R-19 weighted average. §2-5352(b): Loose fill insulation manufacturer's labeled R -Value. §2-535Z(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). §2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §2-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. §2-5352(f): Vapor barrier mandatory iti Climate Zones 14 and 16 only. §2-5317: Infiltration/Exfiltradon Controls a. - Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. §2-5352(e): Special infiltration barrier installed to comply with §2-5351 meets CEC quality standards. §2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed: HVAC and Plumbing System Measures §2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. §2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * §2-5316(a): Ducts constructed, installed and insulated per. Chapter 10, 1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. §2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. :§2-5352(i): Water heater insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater); first 5 feet of pipes closest to tank insulated (R-3 or greater). §2-5312 (Exception I): Pipe insulation on steam and steam condensate return &'recirculating piping. §2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. ,A 4. Time clock. 5. Directional water inlet. Lighting and Appliance Measures §2-53520): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. §2-5314(c): Gas fired appliances equipped with intermittent ignition devices. §2-5314(a):' Refrigeratars, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. Form Revised DeeedMr 1997 DESIGNER I ENFORCEMENT FORM J -1T (Transparent) Including Calculation Procedures A, B, C, D Copyright by the Air Conditioning Contractors of America Formerly: National Envlronmental Systems Contractors Association 1228 17th street N.0 .98 Plan No. Date Calculated by Washington, D.C. 2 Printed in U.S.A. WORKSHEET FOR MANUAL J 1983 LOAD CALCULATIONS FOR RESIDENTIAL AIR CONDITIONING N u Qq s Ca o1V,5 For. Name U y^y E Address . City and state or L E , By; Contractor S /* &E Ad— K' 19 Address . City 6 G /I - Design Conditions ,L Winter •F Outside db • F Inside db Winter Design Temperature Differenco 3 Y •F Summer Outside db 5 'F Inside db 7 F Summer Design Temperpture Difference •F Room RH S6470 Dally Range 3 D Heating Summary A 7 Total Heat Loss toy Entire House (Line 15) = Winter Design Temperature Difference = Btuh •F Ventilation CFM = CFMX_ 3 `/ 'F = Btuh Heat Required for Ventilation Air_= 1.1 X .2 2 21 7 (house) z 2 (Vent) = A 2-01 Btuh Design Heating Load Requirement = Cooling Summary Btuh (Calculation Procedure D) Design Temperature Swings Total Sensible Gain / 3 Btuh (Calculation Procedure D) Normal 3' (> ) 4.5' Total Latent Gain + Ventilation CFM ;z3 Btuh _ Total = Sens. + Lat. _ - Equipment Summary PC -1 l AK Q ups Model s C n' o`/ I e'C C —Type 7 8 ji /e2 Make Heating Output (Btuh) .5,9?DDD Efficiency input (Btuh) Total (Btuh) 45000 Heating (Btuh) `i'<000 Latent Cooling (Btuh) / Sensible Cooling ( '_ /6 00 Heating CFM y o o R Cooling CFM COPIEERISEERIHSPF Cool ( ) Heat/Cool ( ) Night Setback ( )' '" Space Thermostat Heat ( ) Construction Data D Floor Windows Partitions /Z Aip- Doors=—` Walls O F MC Sett— Root cry C, /Teff Ceiling L.p¢ )112. 3 f Basement Walls Ground Slab . o )kI C%if- De Calculation Procedures A, B, C, D Calculation Procedure A - Summer Infiltration for the Entire House 1. Air Changes Per Hour from Table 5 ................................................... = b' D AC/HR 2. Volume of Conditioned Space ........................... = Floor Area X Ceiling Height T — ( j $ & L ) Sq. Ft. X ( ) Ft. = Cu. Ft. 3. Total Infiltration = 0' AC/HR X 1 % Cu. Ft. X 0.0167 = CFM VWi.4LTc4D r,arri,tatlen Procedure B - Summer Infiltration Him For Windows & Doors 1. Design Temperature Difference = Summer Design - Room Temperature 2. Total Infiltration from Calculation Procedure A ............................................ = CFM 3. Sensible Gain = 1.1 X ✓a *FX CFM ...... = 0 S Btuh 4. Total Area of Windows and Doors (Lines 7 & 8 on J) ..................................... = Sq. Ft. 5. Htm = Btuh + Sq. Ft............ = Btuh/Sq. Ft. rIatntilatton Procedure C - Latent Infiltration Gain For The Entire House 1. Grains of Moisture Difference from Table 1 ....................... = gr. 2. Total Infiltration from Calculation Procedure A ......... = CFM 3. Total Latent Load = 0.68 X gr X CFM = Btuh rl l—datrnn Prnrpdura D • EculDment Sizing Calculation Serisible Ventilation Load = 1.1 X Vent CFM X OF Diff. Btuh Sensible Load for Structure from Line 19 ............................................. + Btuh Total Sensible Load .................................. (Structure Load + Ventilation Load) = Btuh Temperature Swing Multiplier ........... X (TSM) Equipment Sizing Load, Sensible ........ = 2 3 E s g Btdh Latent Load for Appliances & People = 230 X 62 No. of People ............... 3 gd Btuh Latent Ventilation Load = 0.68 X Vent CFM X gr (No.1 Calc. Procedure C)+ Btuh Btuh Latent Infiltration Load from Calculation, Procedure C .................................. • • • + j-.3 a Btuh Equipment Sizing Load, Latent .......... _ Enter the Equipment Sizing Loads on the Cooling Summary on the Front of the J-1 Form. Temp. Swing Multipliers Mechanical Ventilation = Vent CFM OF Summer DSN 85-90 41/2 ° 0.85 3° 0.95 Design Temp. Diff. (NoJ; Calculation Procedure B) Diff. 95 0.90 1.00 Design Grains. (No. 1; Calculation Procedure C) gr 100 0.95 1.00 Desired Temp. Swing ( ) 105 1.00 1.05 Temp. Swing Multiplier (TSM) = 110 1.05 1.10 Serisible Ventilation Load = 1.1 X Vent CFM X OF Diff. Btuh Sensible Load for Structure from Line 19 ............................................. + Btuh Total Sensible Load .................................. (Structure Load + Ventilation Load) = Btuh Temperature Swing Multiplier ........... X (TSM) Equipment Sizing Load, Sensible ........ = 2 3 E s g Btdh Latent Load for Appliances & People = 230 X 62 No. of People ............... 3 gd Btuh Latent Ventilation Load = 0.68 X Vent CFM X gr (No.1 Calc. Procedure C)+ Btuh Btuh Latent Infiltration Load from Calculation, Procedure C .................................. • • • + j-.3 a Btuh Equipment Sizing Load, Latent .......... _ Enter the Equipment Sizing Loads on the Cooling Summary on the Front of the J-1 Form. uPL /07y- 7-M45S Yv Name of Room Entire House 1 r/ °O !— 2 Running Ft Exposed Wall q W % s R In: F 3 M,6>,e % /f 1 a -. ,Lel 6 S oom mens ons. t Ceiling Ht. Ft Directions Room Faces TYPE HTM Area Bcuh Area Btuh Arca Btuh Area Btuh Area Btuh Area i Bt, OF EXPOSURE : N°' Htg Clg Length Htg or Clg Length Htg Clg Length i 5 Clg Length Area i Bt, OF EXPOSURE : N°' Htg Clg Length Htg or Clg Length Htg Clg Length i lits Clg Length Htg Clg Length Htg Clg Length lits s Gross a Exposed b Walls and c _ Partitions d Ii 6 Yid'owa a I B 3 $$ I ?,Q I .23 ' (( nCb ' Dors (Heating 1 I i 1 7 Yindows North 700 j t and Glass E &W or NE & NW r(s 7-7 d23S I 9` Doors South or SE &%W Cooling) _ -- --/ --- — — g Other Doors bo 0 J-7 9 Net a /Q ! . r S. 2 D(o S s ! (-- 3%r 20 1 ,105 E:pos7 ed b 1/ t $140 X12 0 - ---'---. 3 a .. _ --i l f 0 --- - -- - - — -- Walls and c Partitions d a 10 Ceilings % I % slo I Ma 1 M j i I i I I 11 Floors 0 rbf 12 Infiltration. -Calc. Proc. B Htm= SOS I I 13 Sub Total Btuh Loss = 6+8 49+10y11 la Duct Btuh Loss 15 Total Btuh Loss = 13+14 16 People ® 300 and Appliances 17 Sensible Btpb Gain= t.e.s.: .:+•:t,:a I , 19 Duct Btuh Gain % i t9 T ful CongB lo RA`n = 1'.•:•17 Z ?J 2.S. i I i I • i 1 oil 11 pig 1111malmen w l l a® 1 0 . ETA Rated in accordance with ARI Standard ' ETL Approved 210. Certification applies only when used with proper components as listed with ARI. CONDENSING UNITS SPLIT SYSTEM FEATURES • Top discharge design for quieter operation • Sweat connect with shut-off valves • External refrigerant connections • Easy to install • Easy to service • Galvanized steel cabinet with integral base rails • Electro coated acrylic finished cabinet • Copper tube / aluminum fin coil employing "state of the art' high efficiency design • Vinyl coated inlet and outlet grille • Isolated compressor compartment (31/2- 5 ton models) • Hermetic compressor • Compressor internally spring mounted and externally rubber mounted • Factory charged with R-22 • Low voltage junction box 5442000501 UNlf--SPECIFICATIONS ?Atodel Numbe► <, . _ CA40i8VKB as s CA4Q9I1YK8 C114036VK6 CA'4042YK8, , CA4048,VKB CA4Q6QVKB{ Electrical Voltage -Phase -Hz 208/230.1.60 Data m A' Vdte erRen M1n•Merc . - $19.0 1eZ401)uM"9:00 85 Minimum, Circuit Ampacily 10.1 14.0 23.5 25.4 29.5 33.0 SWI e S' zB /,Mex lYOrih 'AWGfCu ` , « F » it `' . `,'. °* s` »' -• ' 17 400 9.00 8.80 Time Delay Fuse (Amps) 15 20 25 30 35 4n0 45 - ry -U :ui`AG'd 3' O , +.g0. 50 b A MaxFuse:or HACA«T `e Bre ksr Size Ams „ 15z 25 '30 '3 , 40 q ' 60, Compressor Voltage -Phase -Hz 208/230.1.60 Data FuIlRunnln /LockRotor?Arri ,rcM , ow,3 art Z.9/42 10d!66 „a 14.4 193/u110 21F6I118 « 24,;41138 600 s,- _, ;;79 168/,87 EXTERNAL EXTERNAL EXTERNAL EXTERNAL Crankcase Heater (Type) - - - Fan Data MAP Horsepower/ Type '/al PSC '/s I PSC '/e / PSC 'h / PSC '/a / PSC '/a J PSC 'h I PSC ;- s :x s ... . `s w riy .,' ., z r"•i r 'gt _" '/ v ,... 9 fFull 19O/.,t- UFO 'V,a Emir 2 5,1--- , 2 53G- EAC3024SA/B/C - Speeds / RPM 1/1050 1/1050 1/1050 1/1050 1/1050 1/1050 1/1050 Outdoor RToIaI,Face Area S Ft$ " x _,]OWr, r 7 92 7 92 945 c ' , I' , 3 V,, f3 38/ 32 6, ;. = : A32?6 Coil Data Fins Per Inch / Rows 1611 16/1 16/1 1612 16/1 16/2 16/2 BA3024SKA/B - M 0243A ECMO 4XK 41 24,000 9.00 8.65 a -2S 0 .74 800 Refrigerant Suction I.D. S/B"/,° r/8" ConnectionL>.Iqu d; IA1s ` And Charge Data Factory Charge R-22 (Oz)' 68 69 81 186 102 247 201 Welghts i ,-;,:;Shippin r/;Net (Lbs,, _ ; :,,,, 129 /1241 351a 31 0 147! 142 229g/ 224 , . 2 0 / 205, 248y124$ 248,1243 , PERFORMANCE DATA COOLING., CA4018VKB EAS3018SA - 17,400 9.00 8.80 .76 600 - F '.;' 8' A -. mix== 1eZ401)uM"9:00 85 J5 s EAC3018SA/B - 17 400 9.00 8.80 .76 600 - 7.8 EA 3024SAi:^ - 17" 0 9:00 BA3018SKA / B - 17,400 9.00 8.80 .76 600 - EAA3018SA'MMB Cf A024 EAS3024SA - 24 000 9.00 8.65 .74 800 CA4024VKB o . 25 600 : - -_9:00 < 8:85 :7_4T. 800 EAC3024SA/B/C - 24 000 9.00 8.65 .74 800 7.8 EAH3024SA , 23A. 00 8 40.x- .. :. "7_4x BA3024SKA/B - M 0243A ECMO 4XK 41 24,000 9.00 8.65 a -2S 0 .74 800 CA403OVKB EAA3036SA - 28 800 9.00 1 8.65 .76 1000 - EAH3036SA - 28 000 9.00 8.35 .76 1000 7.8 .8 303'/ N- 28 800 v 9 Q0 8165 J > X10000 a, .063 - EAA3036SA BCM036XKA/B 28.800 9.00 8.65 .76 1000 , CA4036VKB EAA 3.'TV61 ,000a 9:00. 845 7.4_- ' 1200. -. _ a-• , CA4036VKC EAC3036SA/B + TD1 - 34000 9.00 8.45 .74 1200 - .EAH BA3036SKA / B + TD1 - 34 800 9.00 8.65 .77' 1 1200 E y"3 9q BCf A /+8 34 D 9" 74 -2l)Us 7.8 . EAA5036SA - 36,000 9.00 .78 1200 ;EHE 036SA: .. 361000 . , '' ' 75 1200 , di., EAH5036SA - 35.400 1 9.00 .77 1200 .071 -4 EAA3048SA - 42 000 9.00 8.45 .74 1400 CA4042VKB rA x.B. X42 9fm8''45$ 74 00 EAH3048SA + TD1 - 41.000 9.00 8.10 .74 1400 7.8 .077 EHA5048SA BCM060XKA/B 42.500 9.00 8.15 .74 1400 CA4048VK8 EAA3048 S'rT`t 45000? ... , 9.00 .8?95 :: 3 14tjF) + .087-4 CA4048VKC - EAC3048SA+TD1 - 45.000 9.00 8.95 .73 1400 8.0 5048SA - 48 500 9.00 u8.95 .72 1400 60 n , gg 15„ 9 8.9y 74 1'A. :080 a w PH' 5048SA BCM060XKA'/B 48,000 9.00 8.85 .74 1400 080 = mstaner must change indoor con retrigerant control orifice for system match as listed. Correct ofifice(s) shipped with outdoor unit. TD1 = AMA001TDA indoor blower time delay kit required to make SEER indicated. Models not indicated with TD1 can increase SEER by three tenths (3) through the use of this accessory. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE u MANUFACTURED FOR NATURAL & L.P. GAS NOTE: These furnaces are not .designed for installation in a corrosive atmosphere, containing Chlorine, Fluorine, or any other damaging chemicals WARNING This furnace is not designed for use inside mobile homes, trailers, or recreational vehicles. Such use could result in property damage, bodily injury, and/or death. H cuTroM EFFICIENCY s S RATING r CERTIFIED CI s T ' lcpamal SAT1t Design Certified by A.G.A. EFFICIENCY • Solid state electronic intermittent ignition device. • Induced combustion blower. • Fan & Limit control regulates start up & shut down of blower to eliminate cold. air draft and prevent over heating. . HEAT EXCHANGER • Durable cold rolled steel heat exchanger. • Limited 20 year Warranty. VENTING • Furnace may be vented using type B-1, vent pipe and fittings in accordance with installation instructions and local codes. BURNER ASSEMBLY • All steel atmospheric burners. • Stainless steel crosslighters. • Stainless steel burners on L.P. models • One piece manifold. • Fuel matched, performance rated orifices to maximize operating efficiency. BLOWER ASSEMBLY. ' • Quieter more energy efficient blower assembly. • Multispeed, prelubricated PSC motors. Low starting torque to allow quiet acceleration to operating speed. Dynamically balanced. Heavy duty motor brackets. Motors are resilient mounted to reduce vibration and noise. Entire blower assembly mounted on rails for easy service. WIRING CENTER • Redesigned control box with wiring relocated for easier access. • 40VA transformer, DPDT heating/cooling fan relay. • Wiring is uniformly color coded for easy hookup and is conveniently located. • Terminal boards permit easy selection of motor speeds and access to low voltage wiring. CABINET • Computer designed embossed steel welded cabinet. • Electrocoated acrylic finished cabinet. • Heat exchanger compartment insulated with foil faced glass fiber insulation to minimize heat loss and operating sound level. • Low profile design, only 48 high. SAFETY • AGA design certified. • Flame sensor constantly monitors burner flames. • Redundant gas valve for quiet, smooth, safe ignition. • High temperature limit control, prevents overheating. • Pressure switch senses flue blockage and shuts the furnace down if flue is restricted. • Blower door interlock switch prevents furnace from operating when blower is removed. • Prewired at the factory. • 100% safety gas shut off if flame is not sensed. INSTALLATION • Gas line entrance from left or right. • Designed to permit multiple installation options. • Compact design for AGA minimum clearances. 5444102104 3/4„ B If_ C — I M"WIFBFILTER < D +"- 13" RETURN RETURN AIR CABINET DIMENSIONS ACCESS DOOR 3/4„ B If_ C — I M"WIFBFILTER < D +"- 13" RETURN NOT AVAILABLE 75;000 BTUFi' .O O ACCESS DOOR A RETURN MODEL M"WIFBFILTER < R/A CABINETMODELNQ. r 50,000 BTUH NOT AVAILABLE 75;000 BTUFi' 16 t%4 143%4 ( 16 2b z 1ff NAH' GQ LH.Q 18-1/4 16-3/4 (1)16 x 25 x 1 NAHGO02RC 100,000 BTUH 125T000STUH 2s1 3/4 201/4° (1►16 z 25 z 1 NAHG003RC a. ('1►1S Sik. + 1 In. Type B-1 Vent. "BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER." mnf)u1EST@ INTERCITY PRODUCTS CORPORATION( USA) P.O. BOX 3005 LAVERGNE, TENNESSEE 37088-1985 Printed In U.S.A. .);+ ALL DIMENSIONS IN INCHES RESIDENTIAL AND COMMERCIAL SYSTEMS • SPLIT SYSTEMS • PACKAGED AIR CONDITIONERS • COMBINATION GAS / ELECTRIC UNITS • HEAT PUMPS • AIR HANDLERS • MANUFACTURED HOME AIR J CONDITIONERS • GAS, OIL AND ELECTRIC FURNACES SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE PART NO. 5444102104 (11/90) Replaces 5444102103 (7/90) thermostats - T282A, T882A, TS882A CHRONOTHERM CLOCK THERMOSTATS - * FOR COMPLETELY AUTOMATIC NIGHT SETBACK—MORNING •; ud PICKUP TEMPERATURE f ti CONTROL OF A HEAT- •4 ING SYSTEM OR AUTO- { MATIC DAY SETUP FOR " COOLING SYSTEMS. ............ Adjustable program auto- matically lowers and raises temperature control point for one period in every 24 hours. Pickup and setback times need only be set once for continuous operation of the system. Thermostat and concealed wallplate mount on wall or horizontal outlet box. 0611 Subbase can be added to T882A to provide system and fan switching for heating -cooling control. AT75A, AT82A or R7305A,B power supplies only may be used to power the electric clock. Temp. Setting Range: 54 to 86 F [12 to 30 C]. Timer Min. Period on HI Setting: 5-1/2 hours. Timer Min. Period on LO Setting: 4.1/2 hours. Approx. Dimen- sions: 3.3/8 in. (85.8 mm] high, 6.1/16 in. [154 mm] wide, 2-1/8 in. [54 mm] deep. ELECTRICAL RATINGS: T282A and T882A (50/60 Hz): APPLICATION RUNNING INRUSH Heating 1.5 amp 3.5 amp Cooling (T882A) 1.5 amp 7.5 amp TS882A: 0.1 amp at 0.75V dc. Clock power consumption: 1.66 watts. TRADEL INE models. HEAT ANTICIPATORS: T282A—nonadjustable voltage type heat anticipator rated at 25 volts. T882A—heat anticipator adjustable 0.1 to 1.2 amp; nonadjustable cooling anticipator is rated at nominal 29 volts. TS882A—nonadjustable heat anticipator rated at 0.1 amp. ACCESSORIES: Q611 Subbase for system and fan switching. Not for use with R7305A Chronotherm Power Supply (switching subbase is furnished with R7305A). R7305A Chronotherm Power Supply—for replacement of existing low voltage thermostat with Chronotherm Clock Thermostat and utilizing the existing 2 wires. R7305B Chronotherm Power Supply—for replacement of existing line voltage thermostat with Chronotherm Clock Thermostat and utilizing existing 2 wires. 130821A Mounting Plate Assembly—for mounting on vertical outlet box or for covering marks from old thermostat. 1308218 for mounting on horizontal outlet box or for covering marks from old thermostat. AT82A1024 Plug-in Clock Transformer for powering clock in heating -only or heating -cooling application. 104994A Calibration Wrench. AT75A1036 REPLACEMENT PARTS: 129984A Clock Motor (for 60 Hz). 129802A Cover Assembly. Thermostat Guards. See Thermostat Guards section, page 231. ORDER HEAT APPLICATION ANTICIPATOR INCLUDES USE WITH NUMBER TION RATING T282A1024 3 -wire, low voltage 24V, nonadj. Spdt AT75A Transformer for heating. (Series 20) powering clock section. T882A1005 2 -wire, low voltage heating only or 0.1 to 1.2 amp, adj. Spdt AT75A Clock Transformer or AT82AI024 Plug-in Clock Transformer and thermo- T882A1047 Spdt AT75A Transformer for heating - cooling systems (use powering clock section. stat wallplate or AT75A orAT82A1024 and 0611 Subbase (heat -cool) to pro - T882A1054a Spdt AT75A Transformer for 0611 A,B). powering clock section. vide automatic control. R7305A or B Power Supply and T882A1062 Spdt Cool anticipator sized for gas air conditioning; 129918DA or 129918EA Wallplate gas flame logo; AT75A (heat only) to provide 2 -wire Transformer for power- installation. ing clock section. R7305A Power Supply and 130180BA Subbase (heat -cool) to eliminate need T882A1104b Spdt for 2 extra wires for clock. TS882A10108 750 millivolt heat. 0.1 amp Spst AT75A Transformer for ing systems. nonadj. powering clock section. aWith positive OFF. r j bRange: 45 to 75 F (7 to 24 Cl. clncluded with TRADE LI NE- mo TRADFUNE 215