SOL (13-1192)52015 Avenida Martinez
13-1192
T
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 13-00001192
Property Address: 52015 AVENIDA MARTINEZ
APN: 773-231-012-1 -000000-
Application description: SOLAR
Property Zoning: COVE RESIDENTIAL
Application valuation: 17266
Applicant -
I'll ✓
Architect or
•.44
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner: '
STARK, MICAH S
- 80226 ROYAL BIRKDALE DR
INDIO, CA 92201
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
LicensseeCjlasss: B C10 C46 1 %LiccensseNo.: 910836
Date.: .Ll d// ContractorhNm *4"lA \/
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a.signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
.License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Contractor:
RENOVA ENERGY CORP
75181 MEDITERRANEAN AVENUE
PALM DESERT, CA 92211
(760)568-3413
Lic. No.: 910836
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/30/13
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier HDI-GERLING AMR Policy Number EWGCC000104313
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
Date: %V Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit; or cessation of work for 180 days will subject
permit to cancellation. '
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned pr 0'a
insspnec^iion purposes.
Date:_ Signature (Applicant or Agent): lel/ 1
T
Application Number . . . . . 13-00001192
Permit . . . ELECTRICAL 2013
Additional desc .
Permit Fee . . . . 47.66 Plan Check Fee
.00
Issue Date . . . . Valuation . . .
. 0
Expiration Date 3/29%14
Qty Unit Charge Per
Extension
1.00 23.8300 LS ELEC DEVICES, FIRST 20
23.83
1.00 23.8300 EA ELEC SERVICES
23.83
----------------------------------------------------------------------------
Special Notes and Comments
7.8kW SOLAR ARRAY - (24) 327W SUNPOWER
PANELS W/ (1) 7,000W SUNPOWER INVERTER
(435SF) AND 200AMP SERVICE UPGRADE. 2010
CALIFORNIA ELECTRICAL CODE.
September 23, 2013 2:48:47 PM AORTEGA
----------------------------------------------------------------------------
.Other Fees . . .. . . . . . . BLDG STDS ADMIN (SB1473)
1.00
PLAN CHECK, ELECTRICAL
35.75
PERMIT ISSUANCE M/P/E
90.57
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
Permit Fee Total 47.66 .00 .00
47.66
Plan Check Total .00 .00 .00
.00
Other Fee Total 127.32 .00 .00
127.32
Grand Total 174.98 .00 .00
174.98
LQPERMIT
Bin. #
. . .
Crty of La Qurnta
Building 8r Safety Division
P.O. Box 1504,78-495 Calle Tampico
La.QuinU, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Perinit #
ProjeccAddress:52016 Avenida Martinez
Owner'sName: Micah Stark
A. P. Number.
Address: 52015 Avenida Martinez
Legal Description:
Contractor: Renova Energy Corp.
City, sT, zip: La Quin'ta, CA 92253
Telephone, dw—
Project Description: Residential Roof Mounted Solar PV 7.848kW DC
Address:75181(Mediterranean Ave
City, sT, zip: Palm Desert, CA 92211
Telephone: 760-568-3413
c '
City Lia. #:104947
State Lia #: 910836
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone: ,
l
State Lic. #:
Construction Type:. occupancy: Residential.
1 Pro'ect type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: #stories: # Units:
Name of Contact Person: Lea Waki - 760-568-3413
Telephone # of Contact Person: lea@renovasolar.com
Estimated Value of Project: $17,266 •
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACKING PERMIT FEES
Plan Sets
or/(
Plan Check submitted Item Amount
Structural Cafes.
Reviewed, ready for corrections Plan Check Deposit. .
Truss Cafes.
Called Contact Person Plan CheckBalance.
Title 24 Cafes.
Pians picked up Construction
Flood plain plan
Plans resubmitted ' Mechanical
Grading plan
2'a Review, ready for correctionsfissue Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up
H.O.A. Approval
Plans resubmitted Grading
W HOUSE:-
'"' Review; ready for correctio ass Developer Impact Fee
Called Contact Person
Planning Approval
Pub. Wks. Appr
Date of permit Issue
School Fees
To 1
mit ees
QJ --320'2,— oUK AfAW4 f 'co w rU&41*"& At
`.. AUG 3 0.2013
CITY OF LA QUINTA
..-.......... ... ................
COMMUNITY DEVELOPMENT
I baMs I A
s
r — U) rn
D N p > BACK
PROPERTY LINE
Project Namleffi
MICAH STARK jT
YARD
m
L
52015 AVENIDA MARTINEZ
p
v<O3 m
<
momma
v 0
X
5
C
N
p o
z ion
O
0
D
y
M C
'w
z
:MD
7
M N O
C7
o
~
CO
I z
m
z
m
C:
O
rn W
x 0
m
z
II
z in
v
m --I
Z3
m
Z
n
=
_
m
n
m
Z
G7
mr-0
m
v-
m
CD
Hca
cin
-D
0 0
D
V
X
cn-n
cn
z
in
r 0
00
-m
-0G)2
m
zm
m
Cr
D
m(n
T
ON
D
D
?v
.-_.
I baMs I A
I I w
r--WU)p
N
O"-0c:D
DN -0
s
M
mr, 0
Project Namleffi
MICAH STARK jT
o00<
m
L
52015 AVENIDA MARTINEZ
p
v<O3 m
<
x
X
5
O
N
0
O
0
D
y
(7
o0
'w
z
:MD
7
d
o
o
p
CO
W
y v
C:
O
O v
I I w
r--WU)p
N
O"-0c:D
DN -0
M
co
Project Namleffi
MICAH STARK jT
o00<
renova.
L
52015 AVENIDA MARTINEZ
p
v<O3 m
X
x
X
Tu
Fn -<
O
z N
O
O
0
D
y
(7
o0
it W
N
:MD
n
02
-1 O
A2
o
r
p
CO
m rn
a
z
M
M AVENIDA MARTINEZ
O
O
r
rn
O"0DOmXX
nN NOOcn
oTO
m< D b O z
v ZKmM
Or- O D m v K
z --1 x oo m
0
M g m = v
o«
A mom
M KF) >
x -C,m
m ; y
m Z
X m KD.
Ln y r
X Z K A
Cl)1
M
r
F)
E
m
O
OC
Z W
G)
m
O M
0 m
M -n
cV41
r, O
--4<w o
NDS — m
0* o
< -b n D
CD n n
C:)
O
O 0_
Z
n
90 O
z --i
M z
n m
IV
O
O
CD
4 0
0
X -u
0
0`
C < M 0
-i
®mZ
Z D
m O
n D
D
n Cl)
< (1)
U) --I
i m
M
K `^
N
N m
M ••
rn
CO
41 -CO
.A CO
77,
D 0
n n
co
Project Namleffi
MICAH STARK jT
Z;
renova.
L
52015 AVENIDA MARTINEZ
p
W
N
z
0 T
DX
Tu
Fn -<
O
<
In
(np
mm
D
>
D
0
D
C
D$
00 C)
22
m-
002
2
n
02
-1 O
A2
-n 0
r
p
CO
m rn
y v
G)
r
O v
m m
O r (nn
-'
in
z in
v
(nn ai
Z3
m
Z
n
=
_
m
n
m
Z
G7
mr-0
m
v-
Oin
D
cq
Hca
cin
-D
0 0
Z
X
cn-n
z
z
in
pD
-m
-0G)2
m
zm
0-
Cr
D
m(n
T
ON
D
-nm
3
co
*A
>
z
A
(n
cnr
D
o
CnU)
Z -1O
2K
2
OK
Xx
P
M
O
z
;u 0N0
2rn
Z(n
(mn
0
(n
O
N
r
m
au
m
DG
C>
OCC
z
m
N
m
OC
(n
2
=N
m2
m
v
C
Z
v
C
M
x
A
O
!nm
ST
cn0
DOm
ir0
m
mz
n'D
z
n
N
o
cn
-0
_;
mr-
^
v
w
G)
?
z
O
m
m
m
x
D
r
m
m
m
-n
O
N
D
m
m
D
(nm
C0
20
-1-4
D
T
m
m
0
00
r
CDm
O
cn
2
OD
c
0
z
a
T
2
z
O
m
w
Dp
me
r-i(n
nrn
O
0
z
o
T
yg
x
O
m
Z
(n
2r
D
0
. D
rn
ao
-1
m
C
<
0
-n
O
N
(n cn
-v --I
m
0
D
2
_
z
2
r
ao
A
-0 (n
0
0T
z
v
K
X
z
`
m
-n
30
-i
2
n
C
?
_
D
_
0
C
_
-- •(n
0
-n
.. - 71.-
-
o
O<
o
m
0
-n
0
0
D
O
D
r
z
v
m
O
0
m
0
-n
O
n
m
D
0
C
v
'
v
N
D
O
tmn
z
(n
O"0DOmXX
nN NOOcn
oTO
m< D b O z
v ZKmM
Or- O D m v K
z --1 x oo m
0
M g m = v
o«
A mom
M KF) >
x -C,m
m ; y
m Z
X m KD.
Ln y r
X Z K A
Cl)1
M
r
F)
E
m
O
OC
Z W
G)
m
O M
0 m
M -n
cV41
r, O
--4<w o
NDS — m
0* o
< -b n D
CD n n
C:)
O
O 0_
Z
n
90 O
z --i
M z
n m
IV
O
O
CD
4 0
0
X -u
0
0`
C < M 0
-i
®mZ
Z D
m O
n D
D
n Cl)
< (1)
U) --I
i m
M
K `^
N
N m
M ••
rn
CO
41 -CO
.A CO
77,
D 0
n n
co
Project Namleffi
MICAH STARK jT
Z;
renova.
L
52015 AVENIDA MARTINEZ
W NN!m
Im
o a
m'3 "
Renova Energy Corp
LA QUINTA, CA 92253
o'
N o 2
75-181 Mediterranean Ave.
Palm Desert, CA 92260
(760)568-3413
Contractor's License #9108 6
il.
m;o
M
CD
<
0
00
0
@
Project Name
MICAH STARK
rom, nova.
z
0
C--
p
0 Z
@
00
52015 AVENIDA MARTINEZ
75e81M
e'RergynC)apAve.C)
lR
Palm Desert, CA 92260
LA QUINTA, CA 92253
(760)568-3413
Contractor's License #910836
c
WARNING:
ELECTRIC SHOCK HAZARD. DO NOT TOUCH BACKGROUND WARNING:
TERMINALS. TERMINALS ON BOTH THE LIN "RED"AND ELECTRIC SHOCK HAZARD. DO NOT TOUCH ai cam*)
AND LOAD SIDES MAY IT ENERGIZED IN ivTERMINALS. TERMINALS ON BOTH THE LIN co °D
THE OPEN POSITION. "WHITE" AND LOAD SIDES MAY BE ENERGIZED IN iv a c co
LETTERING. THE OPEN POSITION.
OPERATING CURRENT: 17 94 Ams o` m N
P
OPERATING VOLTAGE: 357.07 Volts
1P,3W CIRCUITCODE:
MAX AC OPERATING CURRENT: 29.17 Amps
2
MAXIMUM VOLTAGE: 550.28 Volts
4
OPERATING AC VOLTAGE: 240 Volts
6
SHORT-CIRCUIT CURRENT: 19.38 Amps
C aO EnU
OfL6a o
U
L
8
9
NOTE: MOUNT ON DC DISCONNECT
11
NOTE: MOUNT ON AC DISCONNECT
13
OF SPR -7000m INVERTER
;
* WILEY CABLE CLIPS
3„
3„
'EMT CONDUIT WHERE EXPOSED /ALL METAL CONDUIT -NO SET SCREWS
1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED.
SUPPORT SYSTEM *
WARNING:
WTYPE
C.B.
BACKGROUND
ELECTRIC SHOCK HAZARD
VA LOAD
THIS PANEL IS FED BY TWO SOURCES:
"RED" AND
IF A GROUND FAULT IS INDICATED, THE
8/13/13
SOLAR PHOTOVOLTAIC SYSTEM ON PREMISES
"WHITE"
NORMALLY GROUNDED CONDUCTORS
CV
A B
LETTERING.
MAY BE UNGROUNDED AND ENERGIZED.
A B TR P L R N
U
A B
NOTE: MOUNT ON INVERTER
1 3500 1 Sunpower SPR -7000m Inverter
NOTE: MOUNT ON MAIN SERVICE PANEL COVER
40 40 12
1XI I
L
w
2
3"
L
®WARNING:
THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC
GENERATOR LOCATED ON THE ROOF AS SHOWN. THE
SYSTEM MAY BE DISCONNECTED FROM THE FACILITY
PER THE AC DISCONNECT AS SHOWN.
SITE PLAN
200AMAIN
PAN
PANEL
60 AMP AC
DISCONNECT
(OUTDOOR WEST WALL) SUNPOWER
7000W INVERTER
(INSIDE GARAGE)
WARNING
INVERTER CONNECTION DO NOT RELOCATE
THIS OVERCURRENT DEVICE.
MATERIALS
(24) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES
#SPR-327NE-WHT-D
(1) SUNPOWER SPR -7000m - 7,000 W; 240 VOLT
(1) SQUARE -D AC DISCONNECT, 60A NON -FUSIBLE, 2 -POLE
#DU222RB
SOLAR PRODUCTION SUMMARY
GROSS NAMEPLATE RATING
(24 x 327/1000) 7.848 kW
CEC-AC SYSTEM SIZE 6.944 kW
0 M
m Uc c
01±_-
d
CCU NIAJ
CITY OF LA QUINTA
BUILDING &SAFETY DEPT.PV Installation
W E Company
A r OV E D Renova Energy Corp.
NOTE. MOUNT ON MAINSERVICEPANEL FOR CONSTRUCTION S Calitomla-2072
AT SOLAR BREAKER
3' r
DATE BY A NABican C tP]
PHOTOVOLTAIC DISCONNECT
FOR UTILITY OPERATIONS
NOTES+ SOLAR PRODUCTION STATS. SN/A
2 P.V. PLAN sNIAE
NOTE: MOUNT ON DISCONNECTS
NOTE: MOUNT ON SERVICE PANEL
'ALL PLACARDS SHALL BE RED WITH WHITE LETTERING
PROJECT SIGNAGE SCALE:
N/A
PANEL: MAIN PANELVOLTAGE: 240/120
1P,3W CIRCUITCODE:
1
2
3
4
5
6
7 14 15 16 17 18 19 20 21ai
22 23 24
C aO EnU
OfL6a o
U
L
8
9
10
11
12
13
CITY OF LA QUINTA
BUILDING &SAFETY DEPT.PV Installation
W E Company
A r OV E D Renova Energy Corp.
NOTE. MOUNT ON MAINSERVICEPANEL FOR CONSTRUCTION S Calitomla-2072
AT SOLAR BREAKER
3' r
DATE BY A NABican C tP]
PHOTOVOLTAIC DISCONNECT
FOR UTILITY OPERATIONS
NOTES+ SOLAR PRODUCTION STATS. SN/A
2 P.V. PLAN sNIAE
NOTE: MOUNT ON DISCONNECTS
NOTE: MOUNT ON SERVICE PANEL
'ALL PLACARDS SHALL BE RED WITH WHITE LETTERING
PROJECT SIGNAGE SCALE:
N/A
PANEL: MAIN PANELVOLTAGE: 240/120
1P,3W CIRCUITCODE:
N:NON-CONTINUOUS
N
LOCATION: EXTERIOR WEST WALL
MAIN PANEL SCHEDULE I SCALE:
4
BUS: 200 A
ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE.
L:' LONG -CONTINUOUS
N/A
MOUNTING: FLUSH
Z
R: DEMANDABLE RECEPTACLES
* ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED
;
* WILEY CABLE CLIPS
K:'KITCHEN
AIC RATING: 10,000
'EMT CONDUIT WHERE EXPOSED /ALL METAL CONDUIT -NO SET SCREWS
1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED.
SUPPORT SYSTEM *
VA LOAD
WTYPE
C.B.
BUS C.B. TYPE
II
p
VA LOAD
U
LOAD DESCRIPTION
pp
8/13/13
* SERIES CIRCUITS FUSED AT 20 AMPS DC
3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR.
LOAD DESCRIPTION
CV
A B
U
N R L TR P
A B TR P L R N
U
A B
U
1 3500 1 Sunpower SPR -7000m Inverter
L
40 40 12
1XI I
L
w
2
3 3500
L
-
I 1XIL
4
3500 3500 PHASE TOTALS
I
*ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION
I PHASE TOTALS
E • 1
*1" EMT MINIMUM
PHASE TOTALS A+B
CONNECTED VA (CODE N):
U)>
I'—
TOTAL PHASE A:
3500
CONNECTED VA (CODE L):
7000
TOTAL PHASE B:
3500
CONNECTED VA (CODE R):
_Z
Q
to
CONNECTED VA (CODE K):
TOTAL CONNECTED KVA:
7.00
* EXISTING LOADS UNKNOWN
o
DEMAND KVA
Z
U
TOTAL ADJUSTED KVA:
7.00
Q
TOTAL PANEL AMPS:
29.17
AMPS W/L CL:
29,17
SAFEGUARDS
N
* SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL.
MAIN PANEL SCHEDULE I SCALE:
4
a
ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE.
W
N/A
Z
Drawn By:
* ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED
;
* WILEY CABLE CLIPS
NOTES
JP
'EMT CONDUIT WHERE EXPOSED /ALL METAL CONDUIT -NO SET SCREWS
1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED.
SUPPORT SYSTEM *
Date Drawn::
* ALL EMT SHALL USE OUTDOOR COMPRESSION FITTINGS
to
WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH)
* WIND EXPOSURE C
8/13/13
* SERIES CIRCUITS FUSED AT 20 AMPS DC
3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR.
* CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY
CV
Revision No.
* ALL EQUIPMENT TO BE LABELED 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE * VISIBLE AND ACCESSIBLE
* ADD COMBINER / JUNCTION BOX AS NEEDED
AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM.
C3')
* BLOCKING DIODE INTERNAL IN EACH MODULE
5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL.
BOLTED DIRECTLY INTO RAFTERS.
0
*GROUND FAULT PROTECTION DEVICE BUILT INTERNALLY
U
INTO SUNPOWER INVERTERS
*MODULE GROUNDING PERFORMED WITH ILSCO GBL4DB
LUGS WITH #8 SOLID BARE COPPER AND WEEB CONNECTIONS.
I
*ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION
E • 1
*1" EMT MINIMUM
U)>
I'—
<
_Z
Q
to
E
U
o
Z
U
LN
Q
SAFEGUARDS
* SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL.
MAIN PANEL SCHEDULE I SCALE:
4
a
ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE.
N/A
j
Drawn By:
* ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED
;
* WILEY CABLE CLIPS
NOTES
JP
'EMT CONDUIT WHERE EXPOSED /ALL METAL CONDUIT -NO SET SCREWS
1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED.
SUPPORT SYSTEM *
Date Drawn::
* ALL EMT SHALL USE OUTDOOR COMPRESSION FITTINGS
2. WIRE AND SIZES ARE AS INDICATED OR LARGER.
WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH)
* WIND EXPOSURE C
8/13/13
* SERIES CIRCUITS FUSED AT 20 AMPS DC
3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR.
* CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY
Revision No.
* ALL EQUIPMENT TO BE LABELED 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE * VISIBLE AND ACCESSIBLE
* ADD COMBINER / JUNCTION BOX AS NEEDED
AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM.
* SOLARMOUNT RACKING SYSTEM, LAG
* BLOCKING DIODE INTERNAL IN EACH MODULE
5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL.
BOLTED DIRECTLY INTO RAFTERS.
0
*GROUND FAULT PROTECTION DEVICE BUILT INTERNALLY
Sheet No.
INTO SUNPOWER INVERTERS
*MODULE GROUNDING PERFORMED WITH ILSCO GBL4DB
LUGS WITH #8 SOLID BARE COPPER AND WEEB CONNECTIONS.
I
*ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION
E • 1
*1" EMT MINIMUM
* JUNCTION BOX/ COMBINER BOX ENTRY TO BE COMPRESSION FITTING
SOLAR SYSTEM SIZE: 7.848 kW DC TO IID
UPGRADE EXISTING 125 AMP MAIN SERVICE
ro
CEC AC SYSTEM SIZE: 6.944 kW AC TO 200 AMP MAIN SERVICE 44453 -CWT
SOLAR ARRAY 240/120 VOLT, 2 -POLE 75 KVA C -Phase
Q m 00
(24) SUNPOWER 327 LOCATED ON WEST EXTERIOR WALL High 7.2 kV
Low 120/240 V
o M' N
WATT PHOTOVOLTAIC MODULES (2) #6 THWN-2 MAIN PANEL
#SPR-327NE-WHT-D (1) #6 THWN-2 NEUTRAL AIC RATING 10,000 AMPERES Overhead Transformer
U c a,
> Q
0
3 STRINGS OF 8 MODULES DC DISCONNECT 1 #8 THWN-2 EGC
( ) FUSED AT 20 AMPS SUNPOWER NUMBER OF WIRES: (3) THREE I I
1 #8 THWN-2 GEC
°1 U d
T °o
MODULE PTC RATING 301.4w SINGLE PHASE
SPR -7000m-240 1" EMT
-0 m U1
Cw m rn--v,
1 INVERTER METER # AK1B4-1547
> p o
240 V, 2P l UPGRADE EXISTING 1;5A ! PROPOSED BI-DIRECTIONAL
c ao E "T
l MAIN BREAKER TO 20 ( METER #
fY ^ a c
7
(2) #6 THWN-2 SOLAR 120 AMP
40 AMP B EAKER
o
BREAKER
60 AMP NON FUSIBLE 1 #8 THWN-2 EGC N BAR
1
#8 THWN 2 GEC
LOCATED IN AC DISCONNECT
V EMT
GARAGE SQUARE -D #DU222RB
• C
240V, 2P G BAR
(6) #8 THWN-2 LOCATED NEXT TO
(1) #8 THWN-2 EGC MAIN PANEL
PV Installation
1" EMT uFERt y
Company
GEC -
Renova Energy Corp.
GROUND (2) #6 THWN-2 TO
CaGf°mla - 2012
" ALL WIRING BETWEEN MODULES SHALL BE TYPE USE -2 OR PV -WIRE IF EXPOSED. 40 AMP 2 -POLE
ALL CONDUIT SHALL BE 1" EMT OR LARGER.
OF LA QUINTA SOLAR BREAKERMONITOR/
CITY PV SUPERVISOR
ALL CONDUIT SHALL BE BONDED.
pp INTERNET
Notl1Ae1B1ica"-Boaido1
NABCEf
ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. BUILDING SAFETY DE T. (1) #6 THWN-2 NEUTRAL 120 VOLT
Ot
I
STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED.
ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. 1#8 THWN-2 GEC
FOR CONSTRUCTION - ; #8 TOWN -2 EGC
. EC CONNECTED TO MAIN i
ANEL GND i
MT ENTRY TO MAIN PANEL
DATE BY O BE DETERMINED IN FIELD
I
I
N
W
SINGLE LINE DIAGRAM
ISCALE:
z_
N/A
F-
DC CIRCUITS AC CIRCUITS
Cif Lo
Q 04
N
MODULES TO SUNPOWER 7000W INVERTER
7000W INVERTER TO MAIN PANEL
0')SUNPOWER
Q
3 STRINGS X 8 MODULES = 24 MODULES
Q
MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low°C [via www.solarabcs.org]) x T coefV)) X # modules in series 7000W / 240 VOLT = 29.16A X 1.25[PER NEC 215.2(A)1] = 36.46 AMPS (40 AMP SgLAR BREAKER)
U
MAX VOLTAGE DC= (64.9 +((25°C - 3°C) x. 1766)) X 8 modules in series = 550.28 VOLTS AC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE.
LZ <
6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 10.08 AMPS ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG
(n Q Z
FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER #6 WIRE = 75 AMPS X .58[PER NEC TABLE 310.16 & PER NEC TABLE 690.31(c)] = 43.5 AMPS
2
DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE.E
43.5 AMPS X 1.0[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 43.5 AMPS > 36.46 AMPS = OK
U-)
Q
U
ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG I
z O
- c) Q
(3) #6 THWN-2 AWG WIRE, (2) #8 THWN 2 GROUND
#8 WIRE = 55 AMPS X .58[PER NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS
A) LO J
31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK 1" EMT @ 40% FILL PER NEC TABLE C.1 = (7) #6 THWN-2 WIRES = OK
a
3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND
Drawn By:
1" EMT @ 40% FILL PER NEC TABLE C.1 = (9) #8 THWN-2 WIRES = OK 1
JP.G.
MAIN PANEL BACKFEED CALCOLATION
Date Drawn:
MAIN PANEL CONNECTION CALCULATION ,
8/13/13
UPGRADE EXISTING 125 AMP MAIN SERVICE TO 200 MAIN SERVICE
Revision No.
120% OF 200 AMP BUSS: ALLOWABLE BACKFED AMPS [PER NEC 690.64(B)(2)] = 240
240 AMP - 200 AMP MAIN BREAKER = 40 TOTAL -ALLOWABLE
40 AMP SOLAR BREAKER:5 40 AMPS = OK
0
WORK TO BE PERFORMED ACCORDING TO THE
Sheet No.
FOLLOWING CODES: 2010 CEC, 2010 CBC & NEC 2008
E.2
i
CALCULATIONS
SCALE:
N/A ZZ2
I
Product Data Sheet
Technical Characteristics
DU222RB
(Z\A/ITru nlnT P7I ICIRI C r_r) )An\/ 42n4 OD KIC:KAA 2D
FU
SQUARED 1
tsySchneider Eleciric
List Price $353.00 USD
Availability Stock Item: This item is normally stocked in our distribution facility.
Number of Po -es
2 -Pole
Terminal Type
Lugs
Type of Duty
General Duty -
Maximum Voltage Rating
240VAC
Wire Size
#10 to #2 AWG(AI) - #14 to #2 AWG(Cu) .
Action
Single Throw
Ampere Rating
60A
Approvals
UL Listed File Number E2875
Enclosure Rag ng
NEMA 3R r '
Enclosure Type
Rainproof and Sleet/ice proof (Indoor/Outdoor)
Factory Install' --d Neutral
No
Disconnect Tyoe
Non -Fusible
Mounting Type
Surface
Shipping and Ordering
Category
00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R
Discount Schedule
DE1A
GTIN
00785901491491
Package Quartity
11
Weight
4.7 lbs.
Availability Cole
Stock Item: This item is normally stocked in our distribution facility.
Retumability
Y
Country of Origin
MX
As standards, e pecifications, and designs change from time to time, please ask for confirmation of the information given in this document
k
Generated: 11/17/20.1 17:11:35
O 2011 Schneic er Electric. All rights reserved.
Z?Electric
71
UNI RAC Installation Sheet 225.6 Unirac Grounding Clips and WEEBLugs
10 year limited Product Warranty
See http://www.unirac.com for current warranty
documents and information.
YOUR UNIRAC DISTRIBUTOR
SOLIGENT
Soligent www.s7-6917
ww.soligent.net
FUNIRAC 1411 Broadway Boulevard NE
Albuquerque NM 87102-1545 USA
ane
2
Figure 28. UGC -1 layout for even
and odd number of modules in row.
'X" denotes places to install UGC -1.'
Even Number of Modules in row
Figure 27', Insert-a bole in the '
I,NEEB L= ug; alummurri;tail or through the'
clearance hole in the stainless steel, "
flat washer: `Place the stainless steel
flat washer on the b'ol( oriented
aluminum'rad Place the lug portion
= 1.
on'the bolt dnd stainless steel flat
washer Install stainless steel fl'
washer, lock'washer and nut
Ttghten_tfie nut until the dimples:are
eompleteiy embedded into the rail i!
and lug The embedded dimples make J-_
StoinlessSteel Flot
VJosher'(WEEB)
a S'Wtighimechanicatconnecnon
e
and ensure good electrical connecttion
between the aluminum rail andlthe
`i
1'' through the WEEK;
-
°""" nt®r
Clipsandlugsatesoldsepately.,au
raail ,
.
lanYgypel '
Figure 28. UGC -1 layout for even
and odd number of modules in row.
'X" denotes places to install UGC -1.'
Even Number of Modules in row
JO U N I RAC Installation Manual 907.2 Standoffs & Flashings
Example 3
1 -piece, steel, raised -flange standoff
No-Calkl' flashing
Shingled roof
SolarMount rail
Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install
the standoff, ensuring that (1) both lag bolts are screwed into the rafter, and (2) the raised
flange is oriented parallel to the rail. Insert the flashing under the shingle above and over the
shaft of the standoff. No -Calk"" collar does not require sealing of the flashing and standoff shaft.
Slide mounting bolts along slot on SolarMount rail. Insertfooting bolts through raised flange on
standoff and fasten with flange nuts.
10 year limited, Product Warranty
Unirac, Inc., warrants to the original purchaser
with Unirac's written installation instructions, or
sole discretion. Such repair or replacement shall
("Purchaser") of product(s) that it manufactures
if the Product has been modified, repaired, or
completely satisfy and discharge all of Unirac's
("Product') at the original installation site that
reworked in a manner not previously authorized
liability with respect to this limited Warranty.
the Product shall be free from defects in material
by,Unirac IN WRITING, or if the Product is
Under no circumstances shall Unirac be liable
and workmanship for a period of ten (10) years,
installed in an environment for which it was
for special, indirect or consequential damages
from the earlier of 1) the date the installation
not designed. Unirac shall not be liable for
arising out of or related to use by Purchaser of
of the Product is completed, or 2) 30 days after
consequential, contingent or incidental damages
the Product.
the purchase of the Product by the original
arising out of the use of the Product by the
Manufacturers of related items, such as PV
Purchaser.This Warranty does not cover damage
Purchaser under any circumstances.
modules and flashings, may provide written
the Productthat occurs during its shipment
If.within the specified Warranty period the
warranties of their own. Unirac's limited
storage, or intallation.
storage,
Product shall be reasonably proven to be
Warranty covers only its Product, and not any
This Warranty shall beVOID if installation of
defective, then Unirac shall repair or replace the
related items.
the Product is not performed in accordance
defective Product, or any part thereof, in Unirac's
141Boulevard NE
U
N
I
RAC
■■O
Albu quuer ue
er,gd
N NM 87ioz-i545 USA
P.V
4
_
Standoffs & Flashings Installation Manual 9072 U N I RAS
Planning and installation;
There are many possible configurations of standoffs and flashing., The three'examples
here illustrate major product.varieties and installation settings.
Example 1
2 -
,piece, aluminum, flattop standoff „
Cut an opening in the roofing material over a rafter to accommodate.the flashing riser. Install the standoff, ensuring'that both`lag bolts are
screwed into the rafter. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk collar does not require sealing
HO U N I RAC Installation Manual 907.2 Standoffs & Flashings
Standoffs: 3-,4-, 6-, and 7 -inch lengths in each type
Shaft
O.D. Use Components
Use only with SolarMount standard or HD rails. • Welded standoff
Raised flange 15/8" Secure to rafter with 2 lag screws at opposite • 2 lags, 5/16" x 31/2"` (zinc)
zinc -plated steel corners, orienting the flange parallel to the rails.
Use with SunFrame, SolarMount standard, or • Welded standoff
Flat top 1 -piece I5/8" SolarMount HD rails. Secure to rafter with 2 lag • Bolt, 3/8- x 11/4"
zinc -plated steel screws at opposite corners. Secure L -foot or • Lock washer, 3/8'
+< .... installer -supplied strut directly to standoff with • 2 lags, 5/16- x 31/2
standoff hardware.
20
Flat top 2 -piece
aluminum
Use with SunFrame, SolarMount standard, or
SolarMount HD rails. Secure to rafter with 2
lag screws. Secure L -foot or installer -supplied
15/e strut directly to standoff with standoff hardware.
Especially convenient when installing over
a tile roof because flashing can be precisely
fitted over secured base prior to installation
of shaft.
• Shaft
• Base assembly
• Bolt, 3/8- x 11/4` Flange Head
• Lock washer, 3/8"
• 2 lags, 5/16" x 31/2 * (zinc)
• EPDM Washer
* A lag -bolt removal credit is available wherever an installer prefers to substitute a different lag boltThe installer is solely responsible for determining wheth-
er lags are adequate to handle live and dead loads under wind conditions at the installation site. Wind loads and lag pullout capacities are addressed in
Code -Compliant installation manual for SolarMount (Installation Manual 22 7) and SunFrome (Installation Manual 809).
Flashings for all current standoffs (I5/8' O.D. shaft
(see illustrations, p. 3)
*Packs of 12 flashings
Flashings for other uses (/2' - 11/e' O.D. shaft)
Part no. Dimensions
Collared, galvanized 990109 8.75" x 12.5"
Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water
into a structure from an angle or joint.
Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of
gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi-
pated.
Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need
for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the
shingle below.
The following installation instruction provides an explanation of planning and installation of three different applications.
Part no.*
Dimensions
Collared, galvanized
990101
8.75" x 12.5"
Collared, aluminum
990102
8.75" x 12.5"
Collared, soft aluminum
990103
18" x l 8"
*Packs of 12 flashings
Flashings for other uses (/2' - 11/e' O.D. shaft)
Part no. Dimensions
Collared, galvanized 990109 8.75" x 12.5"
Flashing refers to thin, continuous pieces of sheet metal or other impervious material installed to prevent the passage of water
into a structure from an angle or joint.
Flashing generally operates on the principal that, for water to penetrate a joint, it must work itself upward against the force of
gravity or in the case of wind -driven rain, it would have to follow a tortuous path during which the driving force will be dissi-
pated.
Unirac offers flashings to be used specifically with Unirac standoffs. These flashings are collared, thereby eliminating the need
for the use of sealant between standoff and flashing. The flashing slides over the standoff, under the shingle above, and over the
shingle below.
The following installation instruction provides an explanation of planning and installation of three different applications.
Standoffs & Flashings
Installation Manual 907.2
[1] Installer responsibility
QThe installer is solely responsible for:
• Complying with all applicable local or national
building codes, including any that may
supercede this manual;
• Ensuring that Unirac and other products are
appropriate for the particular installation and
the installation environment;
• Ensuring that the roof, its rafters, connections,
and other structural support members can
support the array under building live load
conditions;
• Using only Unirac parts and installer -supplied
parts as specified by Unirac (substitution of
parts may void the warranty);
• Maintaining the waterproof integrity of the
roof; and
• Ensuring safe installation of all electrical
aspects of the PV array.
M
moon U N I RAC
A HILTI GROUP COMPANY
See www.unirac.com/distributors foryour nearest Unirac distributor.
Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@unirac.com.
:: UNIRAC
A HILTI GROUP COMPANY
SolarMount Beams
Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D
310208C, 310208C -B, 310240C, 310240C -B, 310240D,
410144M, 410168M, 410204M, 410240M
Properties
Units
SolarMount
SolarMount HD
Beam Height
in
2.5
3.0
Approximate Weight (per linear ft)
plf
0.811
1.271
Total Cross Sectional Area
in'
0.676
1.059
Section Modulus (X -Axis)
in
0.353
0.898
Section Modulus (Y -Axis)
in'
0.113
0.221
Moment of Inertia (X -Axis)
in
0.464
1.450
Moment of Inertia (Y -Axis)
in
0.044
0.267
Radius of Gyration (X -Axis)
in
0.289
1.170
Radius of Gyration (Y -Axis)
in
0.254
0.502
SLOT FOR T -BOLT OR
V4" HEX HEAD SCREW
2X SLOT FOR
BOTTOM CLIP 2.500 T1.316
SLOT FOR O
3 8" HEX BOLT
387
750
Y
L► X
SolarMount Beam
SLOT FOR T -BOLT OR
1/4" HEX HEAD SCREW
SLOT FOR
BOTTOM CLIP
SLOT FOR
3/8" HEX BOLT
3.000
_TI
1.385
= I I
y I
-►X
SolarMount HD Beam
Dimensions specified in inches unless noted
SolarMount Beam Connection Hardware
SolarMount L -Foot
Part No. 304000C, 304000D
t
IDL
xa SLOT FOR E
,6 "Non
......._.
xoL
Dimensions specified in inches unless noted
::OUNIRAC
A HILTI GROUP COMPANY
• L -Foot material: One of the following extruded aluminum alloys: 6005-
T5, 6105-T5, 6061-T6
• Ultimate tensile: 38ksi, Yield: 35 ksi
• Finish: Clear or Dark Anodized
• L -Foot weight: varies based on height: --0.215 lbs (98g)
• Allowable and design loads are valid when components are
assembled with SolarMount series beams according to authorized
Bolt UNIRAC documents
L -Foot For the beam to L -Foot connection:
• Assemble with one ASTM F593 W-16 hex head screw and one
ASTM F594 Wserrated flange nut
• Use anti -seize and tighten to 30 ft -lbs of torque
• Resistance factors and safety factors are determined according to part
1 section 9 of the 2005 Aluminum Design Manual and third -party test
results from an IAS accredited laboratory
NOTE: Loads are given for the L -Foot to beam connection only; be
sure to check load limits for standoff, lag screw, or other
attachment method
Applied Load
Direction
Average
Ultimate
Ibs (N)
Allowable Load
Ibs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Sliding, Z±
1766 (7856)
755 (3356)
2.34
1141 (5077)
0.646
Tension, Y+
1859 (8269)
707 (3144)
2.63
1069 (4755)
0.575
Compression, Y-
3258 (14492)
1325 (5893)
2.461
2004(8913)1
0.615
Traverse, X±
486 (2162)
213(949)1
2.28
323 (1436)
0.664
SolarMount Mid Clamp
PartNo. 302101C, 302101D, 302103C, 302104D,
30210513,3021106D _
9.A0 DRSTARM
0E'ritEEri ki001JLE.
I I
Y
:.. 'X
Dimensions specified in inches unless noted
SolarMount End Clamp
Part No. 302001 C, 302002C, 3b2002D, 302003C,
302003D,302004C,302004D,302005C,302005D,
302006C,302006D,302007D,302008C,302008D,
302009C,302009D,302010C,302011C,302012C
61UNIRAC
A HILTI GROUP COMPANY
• Mid clamp material: One of the following extruded aluminum
alloys: 6005-T5, 6105-T5, 6061-T6
• Ultimate tensile: 38ksi, Yield: 35 ksi
• Finish: Clear or Dark Anodized
• Mid clamp weight: 0.050 lbs (23g)
• Allowable and design loads are valid When components are .
assembled according to authorized UNIRAC documents .
• Values represent the allowable and design load capacity of a single
mid clamp assembly when used with a SolarMount series beam to
retain a module in the direction indicated
• Assemble mid clamp with one Unirac'/4"-20 T -bolt and one W-20
ASTM F594 serrated flange nut
• Use anti -seize and tighten to 10 ft -lbs of torque
Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third -
party test results from an IAS accredited laboratory
Applied Load
Direction,
Average
Ultimate
lbs (N)
Allowable
Load
Ibs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Tension, Y+
2020 (8987)
"891 (3963)
2.27
1348 (5994)
0.667
Transverse, Z±
520 (2313)
229 (1017)
2.27
346(1539),
0.665
Sliding; X±
1194 (5312)
490 (2179) 1
2.44 1
741 (3295)
0.620
WAH
WMQUE
TNIfXii*56
_t
Dimensions
End clamp material: One of the following extruded aluminum
alloys: 6005-T5, 6105-T5, 6061-T.6
• Ultimate tensile: 38ksi, Yield: 35 ksi
• Finish: Clear or Dark Anodized
• End clamp weight: varies based on height: —0.058 lbs (26g)
• Allowable and design loads are valid when components are
assembled according to authorized UNIRAC documents
Values represent the allowable and design load capacity of a single
end clamp assembly when used with a'SolarMount series beam to
retain a module in the direction indicated
• Assemble with one Unirac'/4'-20 T -bolt and one'/4'-20 ASTM F594
serrated flange nut
• Use anti -seize and tighten to 10 ft -lbs of torque
Resistance factors and safety factors are determined according to
part 1 section 9 of the, 2005 Aluminum Design Manual and third -
party test results from an IAS accredited laboratory
Modules must be installed at least 1.5 in from either end of a beam
Applied Load
Direction
Average
Ultimate
Ibs (N)
Allowable
Load
lbs (N)
Safety
Factor,
FS
Design
Loads
Ibs (N)
Resistance
Factor,
m
Tension, Y+
1321 (5876)
529(2352)-
2.50
800 (3557)
0.605
Transverse, Z±
63 (279)
14 (61)
4.58
21 (92)
0.330
Sliding, X±
142 (630)
52 (231)
2.72
79(349),
0.555
:: UNIRAC
A HILTI GROUP COMPANY °
SolarMount Technical Datasheet
Pub 110818 -ltd V1.0 August 2011
SolarMount Module Connection Hardware.................................................................. 1
BottomUp Module Clip.................................................................................................1
MidClamp....................................................................................................................2
EndClamp....................................................................................................................2
SolarMount Beam Connection Hardware......................................................................3
L-Foot........................................................................................................................... 3
SolarMountBeams..........................................................................................................4
SolarMount Module Connection Hardware
BE
SolarMount Bottom Up Module Clip
Part No. 302000C
Dimensions specified in inches unless noted
• Bottom Up Clip material: One of the following extruded aluminum
alloys: 6005-T5, 6105-T5, 6061-T6
• Ultimate tensile: 38ksi, Yield: 35 ksi
• Finish: Clear Anodized
• Bottom Up Clip weight: --0.031 lbs (14g)
vt • Allowable and design loads are valid when components are
assembled with SolarMount series beams according to authorized
UNIRAC documents
• Assemble with one'/4"-20 ASTM F593 bolt, one'/" -20 ASTM F594
serrated flange nut, and one 1/4" flat washer
• Use anti -seize and tighten to 10 ft -lbs of torque
• Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third -
party test results from an IAS accredited laboratory
• Module edge must be fully supported by the beam
* NOTE ON WASHER: Install washer on bolt head side of assembly.
DO NOT install washer under serrated flange nut
Applied Load
Direction
Average
Ultimate
Ibs (N)
Allowable
Load
Ibs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Tension, Y+
1566 (6967)
686 (3052)
2.28
1038 (4615)
0.662
Transverse, X±
1128 (5019)
329 (1463)
3.43
497 (2213)
• 0.441
Sliding, Z±
66 (292) 1
27 (119) 1
2.44
41 (181)
0.619
Bright Thinking in Solar
Component Specifications
6o61 -T6 and 6o63 -T5
• SolarMount ballast frame
6.105-T5 aluminum extrusion
SolarMount® rails
Mounting clips and clamps
Tilt legs and L -feet
Two-piece standoffs
Severe Condition 4 (very severe)
zinc -plated welded steel
• One-piece standoffs
18-8 stainless steel
• Fasteners
NNUNIRAC
son
an
Bright Thinking in Solar
Code Compliant
The SolarMount® system is PE certified.
Call l nirac for dOCCmentation applicable
to yo.ir building code
Warranty
Solar%4ountm is covered Ly a .10 -year limited
product warrarty and a 5 -year Limited finish
warranty.
For complete warranties, download any
Solar%4ountm irstallation manual from
our vveb site.
Visit us online at www.unirac.com
SOLARMOUNT® RAIL OPTIONS
PV's most versatile mounting system
SolarMount' HO
HD (heavy duty) rail adds the SolarMount advantage
to PV PoleTops•, U-LAs (see separate data sheets),
and custom applications that require long spans.
ATTACHMENT OPTIONS
Flexible Components Speed Installation
Standoffs
Use standoffs whenever flashed installations
• are required, on tile roofs, for example. Two-
piece aluminum standoff allow precise place-
ment of
a flashing over a secured base prior to the
installation of the standoff itself.
3 All standoff types come in four standard
heights: 3, q, 6, and 7 inches. Appropriate
Flashings are available.
f ( Serrated L -feet
-^` "' •T"'- ,•`' g
Standard for round mount installations on
z;jy r
_ residential and commercial rooftops ,use L -feet
alone above asphalt composition shingles or in
• conjunction with flat top standoffs. Mount
standard or light rails. Configure to either of
two rail heights, one promoting air flow for
cooling, the other offering close -to -the -roof
aesthetics
Strut -in -Tube Style Legs
` a.• - ., quickly set the precise tilt angle required. Styles
`- are available for high profit (i or z legs per
rail) and low profile installations.
' Each series offers three leg lengths so that you
can adjust to exactly the tilt angle you want—
up to a maximum of 60 degrees—without
cutting and drilling at the job site.
Standard SolarMount'
Standard rail gives you ultimate flexibility, including 9 The Fas Foot
bottom mounting and tilt -up options. The technology
y attachment features Eco -Fasten
MODULE MOUNTING technology by the Alpine Snow Guard Company,
allowing attachments to metal, concrete and
Assembly Sequence Is Your Choice wood decks without compromising the integrity
of the roof.
Top Mounting Clamps Bottom Mounting Clips
Ideal for flush mount applica- Use bottom mounting clips 1} Tile Hook
' •standard and HO rail
tions, such as residential rooftops, only) !✓ ( Y) Made from cast aluminum, the tile hook
^°•- where it is most convenient to whenever you prefer to attachment provides SolarMount with a
preassemble the
secure footings and rails before arra ` P Y using cost-effective solution for barrel or Spanish
installing modules, top mounting module mounting holes. the roofs. All required lag bolts and hardware
clamps securely grip any point of Simply fit the clip into its rail
the module frame, freeing you slot over the mounting bolt for are included. Refer to the tile hook engineering
from the constraints of module a secure connection. Adjust the data for max load capabilities.
mounting holes. clip position anywhere along
the rail slot.
KEY BENEFITS
of SolarMount® Rail
Maximum flexibility
Flush, high-profile or
low -profile configurations
Roof or ground mount
Pitched or Flat roof
Ease of installation
Installer -friendly components
Minimized penetration with
longer attachment spans than
competitive products
Designed with customer input
Grounding and wire
management options
Complete technical support
Installation and code
compliance documentation
Online estimator
Person-to-person
customer service
Core component for Unirac
mounting solutions
Three rail options to
accommodate anyjob site
Incorporated into other
major product lines
:e UNIRAC
Bright Thinking in Solar
V o
SO LARMOUNT
PV's most versatile mounting system
SolarMount is the most versatile PV mounting rail system
on the market today.
We've engineered installer -friendly components for maximum flexibility,
allowing you to solve virtually any PV mounting challenge.
The universal SolarMount rail system has three options which can be assembled
into a wide variety of PV mounting structures to accommodate anyjob site.
Unirac provides a technical support system Complete with installation and.code
compliance documentation, an on-line estimator and design assistance to help
you solve the -toughest challenges.
®0O
®®00 RAE
Bright Thinking in Solar Visit us Onllne.at WWW.unirac'.com
Unirac - Solarmount / Sunframe Configurator - Project Specs http://www.unirac.com/configurators/estimator roofinount/?module=par...
Distributed Load Calculation
Description
Variable
Value
Units
Mazmum Absolute Value of Load Combinations
P
18
psf
Nodule Length Perpendicular to Rails
B
5.12
it
Distributed Load (Uplift)
w
-46.04
plf
Distributed Load (Downforce)
w
38.37
plf
Rall Span Information
Description
Variable
Value
Units
Racking Attachment Type
Single L
Racking Attachment
Aluminum FlalTop
Rail preference
SM RAIL 168" CLR
Revised Rail Span
L
6
ft
Allowable Spans
in le L Foot
SM
8.5
ft
Single L Foot
SMHD
12
ft
Double L Foot
SM
8.5
it
Double L Foot
SMHD
12
it
Point Load Calculations (per Code, these are based on ma)dmum allowable spans as shown in chart above)
Description Variable Downforce Uplift Units
Single SM Point Load Force R 326.1 -391.4 lbs
Single SMHD Point Load Force R 460.4 -552.5 lbs
Point Load Calculations for your span are
Rail preference SM RAIL 168"CLR
Revised Rail Span L 6 ft
Solar Mount Point Load Force R 230.2 -276.3 lbs
This engineering report and associated bill of materials is to be evaluated to Unirac SolarMount Code Compliant Installation Manual 227.3 (Pub 110616-1 cc) and SunFrame Code Compliant
Installation Manual 809 (Pub 110518-2cc) which references International Building Code 2003, 2006, 2009 and ASCE 7-05, ASCE 7-02 and California Building Code 2010. The installation of
products related to this engineering report is subjectto requirements in the above mentioned installation manual.
Rev 3.2 - 825/1011
2 of 2 8/15/2013 4:51 PM
Unirac - Solarmount / Sunframe Configurator - Project Specs http://www.unirac.com/configurators/estimator roofmount/?module par...
Solarmount / Sunframe Configurator - Project Specs
Prosect Specs
Part Type
Array Information
Suggested
Name:
Micah Stark
Manufacturer.
Sunpower
Email:
jp@renoyasolar.com
Module Model:
E20/327
Telephone:
1
Module Size:
61.39"x41.18"
SM RAIL 168"CLR
16
Module Rows xCols
2x8
ProlectLocation
310132C
NumberofArrays
2
City, State:
La Quinta, CA
Total Modules
32
Zip code:
92253
Total Kilowatts
10.464
County.
Riverside
$99.20
302104D
Basic Wind Speed:
100 mph (User Modified)
Racking Type
SolarMount Roofmount
Ground Snow Load:
0 psf
Module Orientation
Portrait
SM ENDCLAMP F, W/HDW, DIRK
16
Rail Direction
E -W
Special Notes on Basic
Wind Speed and Snow Load
Aluminum Flat Top
STANDOFF 6"2 PIECE AL, DRK
0.2000 R is the upper elevation limit in feet for the ground snow load value
given.
'0/ve- Part of the county is in a Special Wind Region
Material Takeoff
Part Number
Part Type
Description
Suggested
Quantity
Unit Price
Total
> 7 to 27
degrees
Wind E)qposure
Quantity
psf
Importance Factor
1
310168C
SolarMount Rail
SM RAIL 168"CLR
16
16
$92.00
$1,472.00
310132C
SolarMount Rail
SM RAIL 132"CLR
8
8
$72.00
$576.00
3030020
Splice
SM SPLICE BAR SERRATED DRK
16
16
$6.20
$99.20
302104D
Mid Clamps
SM MID CLAMP, EFJMN, W/HDW, DRK
56
56
$3.42
$191.52
302006D
End Clamps
SM ENDCLAMP F, W/HDW, DIRK
16
16
$2.87
$45.92
004600D
Aluminum Flat Top
STANDOFF 6"2 PIECE AL, DRK
40
46
$15.65
$751.20
304000D
Single L -Feet
SM L -FOOT SERRATED W/HDW, DRK
40
48
$4.54
$218.11
004014C
Flashing
FLASHING OATEY11840GLVLUME
40
48
$6.40
$307.20
008002S
Grounding Lugs
GROUND WEEBLUG#1
40
40
$10.00
$400.00
308001S
UGC Clip
SMGROUNDCLIP #1, UGC -1 SS,
32
32
$2.29
$73.28
Total Price Please note these are list prices. Contact your distributor for your system price. $4,134A3
Engineering Variables
Description Variable
Value
Units
Building Height h
15
ft
Roof Angle
> 7 to 27
degrees
Wind E)qposure
B
psf
Importance Factor
1
1
Wind Speed V
100
mph
Effective Wind Area
100
ft2
Roof Zone
2
psf
Design Wind Load Calculation
Description
Variable
Value
Units
Net Design Wind Pressure (Uplift)
Pnet30 (UP"ft)
-21
psf
Net Design Wind Pressure (Downforce)
Pnet30 (Downforce)
7.3
psf
Adjustment Factor for Height and E)Vosure Category
A
1
Snow Load
Importance Factor
I
t
Design Wind Load (Uplift)
Pnet (Uplift)
-21
psf
Design Wind Load (Downforce)
Pnet (Downforce)
7.3
psf
Load Combinations Calculations
Description
Variable
Downforce
Uplift
Units
Dead Load
D
5
5
psf
Total Design Wind Load
Pnet
10
-21
psf
Snow Load
S
0
Total Load Combination 1
D + 0.75Pnet + 0.75S
12.5
psf
Total Load Combination 2
D + Pnet
15
psf
Total Load Combination 3
D + S
5
psf
Total Load Combination 4
0.60 + Pnet
-18
psf
MaxPbsolute Value Load
18
psf
1 of 2 8/15/2013 4:51 PM
E
Electrical Data
-- - - _
String Inverters SPR -5000m SPR -6000m
SPR -7000m SPR -8000m
AC Nominal Power
5000 W
6000 W
7000 W
7680 W @ 240 V
141 lbs for SPR -5000m,
Inverter Weight
-6000m and -7000m /
8000 W @ 277 V
AC Max Output
148 lbs for SPR -5000m,
Shipping Weight
-6000m and -7000m
Current (@ 208V,
24 A, 21 A, 18A
29A, 25A, 22A
34A, 29A, 25A
N/A, 32A, 29A
240V, 277V):
NEMA 31?
Mounting
Wall Mount
AC Nominal
183 - 229 V @ 208 V
183 - 229 V @ 208 V
183 - 229 V @ 208 V
N/A @208V
Voltage / Range
211 - 264 V @ 240 V
211 - 264 V @ 240 V
211 - 264 V @ 240 V
211 - 264 V @ 240 V
244 - 305 V @ 277 V
244 - 305 V @ 277 V
244 - 305 V @ 277 V
2" -305 V@ 277 V
AC Freq / Range
60 Hz / 59.3 Hz -
60 Hz / 59.3 Hz -
60 Hz / 59.3 Hz -
60 Hz / 59.3 Hz -
60.5 Hz
60.5 Hz
60.5 Hz
60.5 Hz
Power Factor
(Nominal)
0.99
0.99
0.99
0.99
Peak Inverter
Efficiencyienrycy
96.8%
97.0%
97.1%
96.5%
CEC Weighted
95.5% @ 208 V
95.5% @ 208 V
95.5% @ 208 V
N/A @ 208 V
Efficiency
95.5% @ 240 V
95.5% @ 240 V
96.0% @ 240 V
96.0% @ 240 V
95.5%@277V
96.0%@277V
96.0%@277V
96.0%@277V
Recommended
Maximum PV Power
6250 W
7500 W
8750 W
10000 W
(Module @ STC)
DC Input
Voltage Range
250 - 600 V
250 - 600 V
250 - 600 V
300 - 600 V
Peak Power
Tracking Voltage
250 - 480 V
250 - 480 V
250 - 480 V
300 - 480 V
DC Max.
Input Current
21A
25A
30A
30A
DC Voltage Ripple
4%
4%
4%
4%
No. of Fused
_74
-
String Inputs
4
4
4
Power Consumption:
<7W/0.1 W
Operation/Nighttime
Topology
Low frequency transformer
Fused DC Disconnect
Standard; Complies with NEC Standards
Configurable in the Field with integrated grounding kit:
Electrical Grounding
SunPower- Solar Panels: DC circuit positively grounded
Serengeti`- Solar Panels: DC circuit negatively grounded
SPRm EFFICIENCY CURVES
100
95 250 Yd
u 90 310 Vd
LD 480 Vd
85
24.
d
0 80
75
70
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
% of rated output power
Mechanical Data
SPR -5000m, SPR -6000m,
SPR -7000m and SPR -8000m
Shipping Dimensions
W x H x D (inches)
23.5" x 31.0" x 16.0"
Unit Dimensions
W x H x D (inches)
18.4" x 24.1" x 9.5"
141 lbs for SPR -5000m,
Inverter Weight
-6000m and -7000m /
148 lbs for SPR -8000m
148 lbs for SPR -5000m,
Shipping Weight
-6000m and -7000m
/152 lbs for SPR -8000m
Cooling
Forced Air/ Sealed
Electronics Enclosure
Enclosure
NEMA 31?
Mounting
Wall Mount
Bracket Standard
Ambient
Temperature Range
-13 to +113 °F
T-- I
Warranty and -Certifications
Warranty 10 year limited warranty
Compliance: IEEE -929,
Certifications IEEE -1547, UL 1741,
UL1998,FCC
Part 15 A&B
About SunPower
Founded in 1985, SunPower Corp. (Nasdaq: SPWRA, SPWRB) designs, manufactures and delivers the planet's most powerful solar
technology. Residential, business, government and utility customers rely on the company's experience and proven results to maximize
return on investment.
SUNPOWER and the SUNPOWER bgo are kadworks or registered trademarks of SunPower Cvrponation. su n po We rCCI rp. CO m
mJuly 2010 SunPower Corporation. All rights reserved. Specifications included in this datasheet are subject to change without notice. Document N Oaf -16967 RevB
i
BENEFITS
Reliable and Robust Design
Proven track record for durability
and longevity
Effective Power Range
Enables most systems to use a single
inverter rather than multiple units
Commercial Use
Flexible AC voltage output and scalable
building blocks create an easy solution
for commercial applications
High Efficiency
Weighted CEC efficiency of at
least 95.5% and peak efficiency
of at least 96.5%
Reduced Installation Cost
Integrated DC disconnect with fuses
lowers material costs and labor'
requirements
Attractive Aesthetics
Integrated disconnect eliminates
need for visible conduits to inverter
SPR -5000m, -6000m, -7000m and -8000m
Ic
SunPower SPR -5000m, -6000m, -7000m and -8000m
inverters offer superior reliability and performance and
can be easily integrated into residential or commercial
installations. All models are backed by a 10 -year warranty.
sunpowercorp.com
1-800-SUNPOWER
MODEL: SPR-327NE-WHT-D
ELECTRICAL DATA
Measured at Standard Test Conditions ISTC): irradiance of 1000W/m°, AM 1.5, and cell temperature 25° C
Peak Power (+5/-3%)
Pmax
327 W
Cell Efficiency
n
22.5%
Panel Efficiency
1`1
20.1 %
Rated Voltage
Vmpp
54.7 V
Rated Current
Impp
5.98 A
Open Circuit Voltage
Voc
64.9 V
Short Circuit Current
Isc
6.46 A
Maximum System Voltage
UL
600 V
Temperature Coefficients
Power (P)
–0.38%/K
Voltage (Vac)
–176.6mV/K
Current (Isc)
3.5mA/K
NOCT
45a C +/– 2a C
Series Fuse Rating
20A
Grounding
Positive grounding not required
jWnj (A)- 2XUN6(26)OLES (B)-GRO gDIN( H)OLES
IN CURVE
71000 W/rn of 50° C
6 tf )Dwlaa – —
5 --
a 4 so3w/1
c
t 3
v' 2 500 w/rltz
I
1
200 W/ ' —
0 _
0 10 20 30 40 50 60 70
Voltage M
Current/voltage characteristics with dependence on irradiance and module temperature.
TESTED OPERATING CONDITIONS
Temperature – 40a F to +1 BY F (- 40a C to + BY C)
Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow)
w/specified mounting configurations
50 psf 245 kg/m2 (2400 Pa) front and back
(e.g. wind)
Impact Resistance Hail: (25 mm) at 51 mph (23 m/s)
WARRANTIES AND CERTIFICATIONS
Warranties 25 -year limited power warranty
10 -year limited product warranty
Certifications Tested to UL 1703. Class C Fire Rating
DIMENSIONS
30[1.181
B B11H
0
ENDSJ
46 (1.811
12[.47)
2X 11.0(.431
-- 2x577[22.701 180[7.071 -
322[12.69)(-- 4X 230.8 [9.091
915(36.021
1200[47.241
1535[60.451
Please read safety and installation instructions before using this product, visit sunpowercorp.com
for more details.
® 2011 SunPower Corporation. SUNPOWER, the SunPower Logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON ore trademarks or registered trademarks s u n p owe rc o r p . c o m
of SunPower Corporation in the US and other countries as well. All Rights Reserved. Specifications included in this detasheet are subject to change without notice. Document 9001.65484 RevB / LTR EN
cs 11 316
MECHANICAL DATA
Solar Cells
96 SunPower MaxeorJm cells
Front Glass
High -transmission tempered glass with
anti -reflective AR coating
Junction Box
IP -65 rated with 3 bypass diodes
Dimensions: 32 x 155 x 128 mm
Output Cables
1000 mm cables / Multi -Contact (MC4) connectors
Frame
Anodized aluminum alloy type 6063 (black)
Weight
41.0 lbs (18.6 kg)
jWnj (A)- 2XUN6(26)OLES (B)-GRO gDIN( H)OLES
IN CURVE
71000 W/rn of 50° C
6 tf )Dwlaa – —
5 --
a 4 so3w/1
c
t 3
v' 2 500 w/rltz
I
1
200 W/ ' —
0 _
0 10 20 30 40 50 60 70
Voltage M
Current/voltage characteristics with dependence on irradiance and module temperature.
TESTED OPERATING CONDITIONS
Temperature – 40a F to +1 BY F (- 40a C to + BY C)
Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow)
w/specified mounting configurations
50 psf 245 kg/m2 (2400 Pa) front and back
(e.g. wind)
Impact Resistance Hail: (25 mm) at 51 mph (23 m/s)
WARRANTIES AND CERTIFICATIONS
Warranties 25 -year limited power warranty
10 -year limited product warranty
Certifications Tested to UL 1703. Class C Fire Rating
DIMENSIONS
30[1.181
B B11H
0
ENDSJ
46 (1.811
12[.47)
2X 11.0(.431
-- 2x577[22.701 180[7.071 -
322[12.69)(-- 4X 230.8 [9.091
915(36.021
1200[47.241
1535[60.451
Please read safety and installation instructions before using this product, visit sunpowercorp.com
for more details.
® 2011 SunPower Corporation. SUNPOWER, the SunPower Logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON ore trademarks or registered trademarks s u n p owe rc o r p . c o m
of SunPower Corporation in the US and other countries as well. All Rights Reserved. Specifications included in this detasheet are subject to change without notice. Document 9001.65484 RevB / LTR EN
cs 11 316
20% EFFICIENCY
SunPower E20 panels are the highest
efficiency panels on the market today,
providing more power in the same
amount of space
MAXIMUM SYSTEM OUTPUT
Comprehensive inverter compatibility
ensures that customers can pair the highest -
efficiency panels with the highest -efficiency
inverters, maximizing system output
REDUCED INSTALLATION COST
More power per panel means fewer panels
I per install. This saves both time and money.
RELIABLE AND ROBUST DESIGN
SunPower's unique Maxeon'"cell
j technology and advanced module
I design ensure industry-leading reliability
t
I MAXEONT"' CELL
I TECHNOLOGY
I Patented all -bock -contact solar cell,
providing the industry's highest
efficiency and reliability
E 6
SERIES
THE WORLD'S STANDARD FOR SOLAR'
SunPower' E20 Solar Panels provide today's highest efficiency and
performance. Powered by SunPower Maxeon'm cell technology, the E20
series provides panel conversion efficiencies of up to 20.1 %. The E20's
low voltage temperature coefficient, anti -reflective glass and exceptional
low -light performance attributes provide outstanding energy delivery per
peak power watt.
SUNPOWER'S HIGH EFFICIENCY ADVANTAGE
20%
15%
10%
5%
SERIES SERIES SERIES
sunpowercorp.com