Loading...
SFD (15530) + BLCK (15223)52198 Avenida Martinez 15530 15223 tf P.O: BOX 1504 No. 15530 Building 78-495 CALLE TAMPICO Address 52--138 Avenida Martinez LA QUINTA, CALIFORNIA 92253 Owner William J. Cox and Sona Mailing BUILDING: TYPE CONST. OCC. GRP. Address 66_300 Dillon Road A.P. Number 773-232-011 Cityt•- " Zip Tel. " ' Desert Hot Spr ngs 92240 251-3780 Legal Description Lot 12 BloCk35 Contractor Project Description SPD same as above: Address City Zip Tel.: State Lic. City & Classif. 143957 Lic. # 2236 sq. Ft. 2257 No. No. Dw. Arch:, Engr., Size Stories Units Designer New Ll• Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. P+tarmit dries not include block City Zip State wall- rLc Gk Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby aff'!rm tht I am licensed under provisions of Chapter 9 (commencing with Section 7000) of D, IvisiOn 3 )f the licensed anl Professions Cod and my license is in full force and effect. !\ $IGNATl I DATE OWNER -BUILDER DECLARATION Estimated Valuation L I hereby affirm that I am exempt from the Contractors License Law for the following $ A2 reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to PERMIT AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. 250100 subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. 214, 21 do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and COr1St. A t Professions Code: The Contractor's License Law does not apply to an owner of property who 5 . 0 0 builds or Improves thereon and who does such work himself or through his own employees. Much. provided that such improvements are riot Intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden Electrical of proving that he dM not build or improve for the purpose of sale.) 0 ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for S. M. 1. such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1 O 1 am exempt under Sec. B. & P.C. for this reason Grading n + Driveway Enc. :Date Owner Infrastructure 1747.42 Prpt-trip Plan 79; - 13A WORKERS' COMPENSATION DECLARATION I hereby aftip that 1 have a certificate of consent to self -insure, or a certificate of Worker's Co ens Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. company ,,.WCopy is filed with the city. O Certified copy is hereby furnished. TOTAL 7 S 22 R 7_5 Q CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS'COMPENSATIONINSURANCE (This section need not be completed If the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any pDarson in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. n, after making this Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear rop. Line WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND Side Street Setbadkaf om Center,Line SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE / HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Side Setback from Property Liner DAMAGES AS PROVIDED FOR IN SECTION 3708 OF THE LABOR CODE, INTEREST, AND yJ_ U ATTORNEY'S FEES. i& Thls is a buildin FINAL DATE INSPECTOR g permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. Issued by: Date` Permit" I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. 09/ mentioned property for inspection purposes. Validated by: Signature of applicant Date Mailing Address Validation: \ City, State, Zip f CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBIW F?:ES a 1ST FL. SO. FT. ® $ 2ND FL. SO. FT. POR. SO. FT. ® GAR. SO. FT. ® CARP. SO. FT. WALL SO. FT. ® SO. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation BONDING FLOOR DRAIN MECHANICAL FEES FORMS % 9 v , WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER /'AS (ROUGH) GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPJEQUIP. LAUNDRY TRAY AIR HANDLING UNIT CFM I KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB FINAL INSP. / SO. FT. ®c IWATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1+/4 c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ac HOUSE SEWER VENTILATION GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING. NDERGROUND A.C. UNIT COLL. AREA SLAB GRADE g ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS % 9 v , SEWER S ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. /'AS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE _ GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. / FRAMING /d FINAL INSP. ROOFING ` / i y } Q Aw REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION /J CERT. OCC. k FENCE FINAL INSPECTOR'S SIONATURESIINITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111. NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 8/11/95 1 Type of Permit I La Quinta No. 113608-7 Permit # Owner Name William J. Cox & Sons Log No. 52198 Street Avenida Martinez city La Quinta Zip 92253 Study Area 112 APN # 773-232-011 1 Tract # Lot # 12 Square Footage 11257 Type of Development Single Family Residence No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to.the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.72 X 1257 or $ 2,162.04 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By William 1. Cox & Sons Name on the check By Dolores A. Ballesteros Superintendent Fee collected /exempted by Pauline Pearson Telephone-. ) X51-3780 T y7 ' Cx '!W fr.A rt!Fr r Payment Received,ZI $2,162'0c4`6h ck No. 5038 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/ Receipt Copy - Accounting Ll JUN -21-95 WEIR 12:48 COX CONSTRUCTION ' -- ECORDING REQUESTED BY CHSCAGO TITLE COMpAWy AND WHEN RECORDED MAIL TQ (WILLIAM J. COX P -O- BOX 967 PALM DESERT, CA. 92261 6192510862 F:: 01 13 7462 , RECEIVED FOR RECORI) AT 2'00 O'CLOCK ire.. MAY 1 " 1995 ; . Trwww Taxwooto.e In t drt tiaotrds ' 5 i'riC K. JOHNSON L —j R}v. CO. K Escrow No. 05242 -23 -Order No. Sala - SPACE. ABOVE MIS UNE FOR Wt OWrtS USE . E. GRANT DEED THE UNDERSIGNED GRANTORS) DELLA (S) DOCJMFNfARYTRANSFER TAXIS •$14.30 1 unincorporated area Gh,of computed on the full value of the Interest or property conveyed, or is Q computed on the full value less the value of liens or encurnbrarwes .remaining at time of We, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, V. SHAW and MABEL W. SHAW, HUSBAND AND WIFE hereby GRANT(S) to WILLIAM J. COX, A MARRIED MAN, AS HIS SOLE AND SEPARATE PROPERTY No: .7-Q h (),;)6 -C/7 the following described real property in the County Of RIVERSIDE , State of California: LOT 12, BLOCK 95, UNIT 1l ANTA CARMELITA TRACT, AS SHOF7N BY MAP RECORDED IN BOOK Is PAGE 75 OF MAPS ON FILE IN THE OFFICE OF THE COUNTY RECORDER OF RIVERSIDE COUNTY, CALIFORNIA APN: 773232-011 AS MORE PARTICULARLY DESCRIBED ON THE ATTACHED EXHIBIT "A" Dated March 14, 1995 MADE A PART HEREOF BY REFERENCE STATS OF CALIFORNIA COUNTY OF } on before me, i a Notary Public In and for said County and State, personally appeared r )'f personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(e) whose nama(a) i4/ore subscribed to the within Instrument and acknowledged to me that he/she/they executed the same In hie/her/their authorized capacity(es), and that by his/her/their signature(S) on the Instrument the person(s), or the entity upon behalf of which the person acted, executed the Instrument. WITNESS y and offici 1. Signature otary MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE: -V- SHAW I ' MABEL W. SHAW p09iN NI f+NRMAN CtihNrlIV1619q z "day PuNc — CoBfomla OwGecoutm W COMM. 0q*93 AMR 11,1945 FOR NOTARY $EAS oA syAup IF NO PARTY SO SHOWN, KWL AS DIRECTED ABOVE Y Naive Street Addres& City, State 8 7ip QQ1-0a/oryea►,r _ I&Af41& (fftr-t of Ea Ouinta rin? s fe# 31talto'sion This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 52-198 Avenida Martinez Use Classification' Single Family Dwelling Bldg. Permit No. 15530 Group R3 Type Construction VN Fre Zone \. c M William J. Cox and Sons 2 s This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 52-198 Avenida Martinez Use Classification' Single Family Dwelling Bldg. Permit No. 15530 Group R3 Type Construction VN Fre Zone Use Zone. SR William J. Cox and Sons 66-900 Dillon Road Owner of Building ,address city Desert Hot Springs, CA., 92240 Daniel P. Crawford Jr. BY,, Date: November 29, 1995 Building Official r0sT IN A OON>!?ICUOU! SLAC[ n COMPUTER METHOD SUMMARy page 9 Pro ect Address........ Cox plan 1257 South Date. •-... 08/10/95 Documentation Author... Carole nChristensen, EA Company ................ Carole Christensen, EA uan g arm Telephone .............. 1-800-735-8152 Compliance Method...... aecc a eMICROPAS4 by Enercomp, Inc,Climate Zone......15 ieec a e E7,7"7777-57Sle-COX12Wth-CTZ15S92 Program -FORM C -2R Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 MICROPAS4 ENERGY USE SUMMARY Energy Use (kBtu/sf-yr) Standard Proposed Compliance 10684 Design Design Margin Space Heating........., Space Cooling.......... 2.78 3.04 -0,26 Water Heating.......... 33.72 15.99 32.10 1.62 15.99 0.00 Total 52.49 51.13 1.36 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type. ....., Construction Type . Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type......,,,, Floor Construction Type.... Number of Building Zones... Conditioned Volume.. Footprint Area ............. Ground Floor Area.,,,,,,,,, Slab -On -Grade Area......., Glazing Percentage.. Average Ceiling Height..... 1257 sf Single Family Detached New Front Facing 180 deg (S) 1 1 ReducedYear Slab On Grade (Package D) 1 10684 cf 1257 sf 1257 sf 1257 sf 11.2 % of FA 8.5 ft I I COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Cox Plan 1257 South Date........ 08/10/95 R MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 BUILDING ZONE INFORMATION Floor # of vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (of) Units itioned Type (ft) (sf) HOUSE Residence 1257 10684 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 104 0.090 R-13 180 90 No W.13.2X4.16 Front 2 Wall 184 0.090 R-13 180 90 Yes W.13.2X4.16 Front 3 Wall 120 0.090 R-13 270 90 No W.13.2X4.16 left 4 Wall 272 0.090 R-13 0 90 Yes W.13.2X4.16 back 5 Wall 239 0.090 R-13 90 90 Yes W.13.2X4.16 right 6 Wall 239 0.082 R-13 180 90 No W.13.GARAGE right 7 Roof 1257 0.034 R-38 270 18 Yes R.38.2X4.24A attic 8 Door 17 0.330 R-0 180 90 No None solid wood 9 Door 20 0.330 R-0 180 90 No None solid wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 10 SlabEdge 17 0.900 R-0 No to outside 11 SlabEdge 118 0.720 R-0 No to outside 12 SlabEdge 13 0.550 R-0 No to garage 13 SlabEdge 19 0.500 R-0 No to garage FENESTRATION SURFACES # of Vent SC SC Interior Area pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt. Only Shade Description HOUSE 1 Window 20.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 2 Window 32.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 3 Window 6.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 4 Window 9.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 5 Door 33.3 2 Metal Slider 0.780 0 90 0.88 0.78 Drapes.Std 6 Window 25.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std 7 Window 16.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Cox Plan 1257 South Date........ 08/10/95 MICROPAS4 v4.02 File-COX1257S Wth-CT215S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 OVERHANGS AND SIDE FINS Window- Overhang Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext HOUSE 1 Window 2 Window 3 Window 4 Window 5 Door 20..0 4.0 5.0 32.0 4.0 4.0 6.0 3.0 2.0 9.0 3.0, 3.0 33.3 6.8 5.0 n/a Surface 0.5 Mass Type HOUSE 1 S1abOnGrade 2 S1abOnGrade HOUSE 2.0 0.5 n/a n/a 2.0 0.5 n/a n/a 2.0 0.5 n/a n/a 2.0 0.5 n/a n/a 2.0 0.5 n/a n/a EXTERIOR SHADING Area Shading (sf) Type Left Fin Right Fin- Dpth Hght Ext Dpth Hght n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1 Window 20.0 Bldg Shade THERMAL MASS Area Thick Heat Conduct- Surface (sf) '(in) Cap ivity R -value 318 3.5 939 3.5 System Type HOUSE Gas ACSplit 28.0 0.98 R-0.0 28.0 0.98 R-2.0 HVAC SYSTEMS Minimum Duct Efficiency Location SC of Ext Shade 0.20 Location/Comments kit.bath.di.n.hall typical Duct Duct R -value Efficiency 0.780 AFUE Attic R-5.2 0.835 10.00 SEER Attic R-5.2 0.820 WATER HEATING SYSTEMS Number Tank External in Energy. Size insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title......".... Cox Plan 1257 South Date........ 08/10/95 Project Address........ a Quin a, CA Documentation Author... Carole Christensen, EA Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 BuilaingPer—m-1-F-7 Plan Check / 5-a-f-e- FieldCheck/ D a e MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 GENERAL INFORMATION Conditioned Floor Area..... 1257 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Stories.......... 1 - Floor Construction Type.... Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall R-13 0.090 Front, left, back, rigit Wall R-13 0.082 right Roof R-38 0.034 attic Door R-0 0.330 solid wood SlabEdge R-0 0.900 to outside SlabEdge R-0 0.720 to outside SlabEdge R-0 0.550 to garage SlabEdge R-0 0.500 to garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (S) 20.0 0.820 2 Drapes.Std Bldg Shade Yes Metal Window Front (S) 32.0 0.820 2 Drapes.Std None Yes Metal Window Back (N) 6.0 0.820 2 Drapee.Std None Yes Metal Window Back (N)" 9.0 0.820 2 Drapes.Std None Yes Metal Door Back (N) 33.3 0.780 2 Drapes.Std None Yes Metal Window Right (E) 25.0 0.820 2 Drapes.Std None None Metal Window Right (E) 16.0 0.820 2 Drapes.Std None None Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Cox Plan 1257 South Date........ 0$/10/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 Type SlabOnGrade S1abOnGrade Equipment Type Gas ACSplit Exposed Yes No THERMAL MASS Area Thickness (sf) (in) Location/Comments 318 3.5 kit.bath.din.hall 939 3.5 typical HVAC SYSTEMS Minimum Duct Efficiency Location 0.780 AFUE Attic 10.00,SEER Attic WATER HEATING SYSTEMS Duct Thermostat R -value Type R-5.2 Setback R-5.2 Setback Number in Tank Type Heater Type Distribution Type System Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS Tank External Energy Size insulation Factor (gal) R -value CERTIFICATE OF COMPLIANCE: RESIDENTIAL ' Page 3 CF -1R Project Title.......... Cox Plan 1257 South Date........ 08/10/95 MICROPAS4 v4.02 File-COX1257S Wth--CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.7BAC10.OR13.38.5.2 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... John Cox Company. William J. Cox & Sons Address. P.O. Box 967 Palm Desert CA Phone... (619) 251-3780 License. Signed.. (d -Y 6 ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Carole Christensen, EA Company. Carole Christensen, EA Address. 47-596 Lake Canyon Dr. Aguanga, CA 92536 Phone... 1-800-735-8152 Signed., 8 TITLE -Z4 ENERGY CALCULATIONS Carole Christensen, Energy Analyst ENERGY CALCULATIONS FOR: Wm. J. Cox & Sons 66-900 Dillon Road Desert Hot Springs, CA 92240 PROJECT: Cox Plan 1257 South Address: La Quinta, CA Standard Proposed 53.26 50.89 Compliance +2.37 CTZ 15 g Dual glazing, Std Drapes Walls R-13, Roof R-38 attic; Duct R-5.2; AFUE 78; A/C SEER 10.0; 50 gal or less gas water heater, EF .53 CONTENTS CF -1R MF -1R C -2R C -3R HVAC Sizing Fenestration Specifications CF -6R to be posted and completed on site when equipment is installed 47-596 Lake Canyon Drive, Aguonga, CA 91536 79-733 Country Club Drive, Bermuda Dunes, CA 92201 1-800-735-8152 Alember CABEC California Association of Building Energy Consultants CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Cox Plan 1257 South Date........ 08/07/95 ' t TAtle Projeci .......... Project Address........ La Quin a, CA Documentation Author... Carole Christensen, EA Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permit Plan Check Date Field Check/ Da e MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ..... Building Front Orientation. Number of Dwelling Units... Number of Stories.. ....... Floor Construction Type.... 1257 sf Single Family Detached New Front Facing 180' deg (S) 1 1 Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly R -value U -Value Location/Comments Type Wall R-13 0.090 Front, left, back, right Wall R-13 0.082 right Roof R-38 0.034 attic , Door R-0 0.330 solid wood S1abEdge R-0 0.900 to outside S1abEdge R-0 0.720 to outside S1abEdge R-0 0.550 to garage SlabEdge R-0 0.500 to garage •' FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (S) 20.0 0.820 2 Drapes.Std Bldg Shade Yes Yes Metal Metal Window Front (S) 32.0 0.820 2 2 Drapes.Std Drapes.Std None None Yes Metal Window Back Window Back (N) (N) 6.0 9.0 0.820 0.820 2 Drapes.Std None Yes Metal Metal Door Back (N) 33.3 0.780 2 2 Drapes.Std Drapes.Std None None Yes None Metal Window Back Window Right (N) (E) 25.0 16.0 0.820 0.820 2 Drapes.Std None None Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S9,2 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 318 3.5 kit.bath.din.hall S1abOnGrade No 939 3.5 typical HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Gas ACSplit Tank Type 0.780 AFUE Attic R-5.2 Setback 10.00 SEER Attic R-5.2 Setback , WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM CF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations tc implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... John Cox Name.... Carole Christensen, EA Company. William J. Cox & Sons Company. Carole Christensen, EA Address. P.O. Box 967 Address. 47-596 Lake Canyon Dr. Palm Desert CA Aguanga, CA 92536 Phone... (619) 251-3780 Phone... 1-800-735-8152 License. 1 Signed.. Signed.. (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 Project Address........ La Quin a, CA Documentation Author... Carole Christensen, EA Company ................ Carole Christensen, EA Telephone.. ............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Perms Plan Check Date Field Check/ Date MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM MF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... Cox Plan °1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM MF -1R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/ exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.).. LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 Project Address........ La Quin a, CA Documentation Author... Carole Christensen, EA Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permit Plan Check Da - e Field Check/ Date MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.87 3.49 -0.62 Space Cooling.......... 34.40 31.41 2.99 Water Heating.......... 15.99 15.99 0.00 Total 53.26 50.89 2.37 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 1257 sf Single Family Detached New Front Facing 180 deg (S) 1 1 ReducedYear Slab On Grade 1 10684 cf 1257 sf 1257 sf 1257 sf 11.2 % of FA 8.5 ft (Package D) COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 Floor Area Zone Type (sf) HOUSE Residence BUILDING ZONE INFORMATION # of Volume Dwell Cond- (cf) Units itioned Vent Special Thermostat Height Vent Area Type (ft) (sf) 1257 10684 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 10 S1abEdge 17 0.900 R-0 No to outside 11 S1abEdge 118 0.720 R-0 No to outside. 12 S1abEdge 13 0.550 . R-0 No to garage 13 S1abEdge 19 0.500 R-0 No to garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 20.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 2 Window 32.0 2 Metal Slider 0.820 180 *90 0.88 0.78 Drapes.Std 3 Window 6.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 4 Window 9.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 5 Door 33.3 2 Metal Slider 0.780 0 90 0.88 0.78 Drapes.Std 6 Window 25.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 7 Window 16.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 124 0.090 R-13 180 90 No W.13.2X4.16 Front 2 Wall 216 0.090 R-13 180 90 Yes W.13.2X4.16 Front 3 Wall 120 0.090 R-13 270 90 No W.13.2X4.16 left 4 Wall 320 0.090 R-13 0 90 Yes W.13.2X4.16 back 5 Wall 280 0.090 R-13 90 90 Yes W.13.2X4.16 right 6 Wall 239 0.082 R-13 180 90 No W.13.GARAGE right 7 Roof 1257 0.034 R-38 270 18 Yes R.38.2X4.24A attic 8 Door 17 0.330 R-0 180 90 No None solid wood 9 Door 20 0.330 R-0 180 90 No None solid wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE 10 S1abEdge 17 0.900 R-0 No to outside 11 S1abEdge 118 0.720 R-0 No to outside. 12 S1abEdge 13 0.550 . R-0 No to garage 13 S1abEdge 19 0.500 R-0 No to garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 20.0 2 Metal Slider 0.820 180 90 0.88 0.78 Drapes.Std 2 Window 32.0 2 Metal Slider 0.820 180 *90 0.88 0.78 Drapes.Std 3 Window 6.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 4 Window 9.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 5 Door 33.3 2 Metal Slider 0.780 0 90 0.88 0.78 Drapes.Std 6 Window 25.0 2 Metal Slider 0.820 0 90 0.88 0.78 Drapes.Std 7 Window 16.0 2 Metal Slider 0.820 90 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM C -2R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 OVERHANGS AND SIDE FINS WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS External Insulation R -value Window- Overhang Left Fin Right Fin - Area I Left Rght ' Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 20.0 4.0 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 32.0 4.0 4.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 6.0 3.0 2.0 2.0' 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 9.0 3.0 3.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 33.3 6.8 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a EXTERIOR SHADING Area Shading SC of Surface (sf) Type Ext Shade HOUSE 1 Window 20.0 Bldg Shade 0.20 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity. R -value Location/Comments HOUSE 1 S1abOnGrade 318 3.5 28.0 0.98 R-0.0 kit.bath.din.hall 2 SlabOnGrade 939 3.5 28.0 0.98 R-2.0 typical ' HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE Gas 0.780 AFUE Attic R-5.2 0.835 ACSplit 10.00 SEER Attic R-5.2 0.820 WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS External Insulation R -value CONSTRUCTION ASSEMBLY Page 1 3R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 r MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13..38.5.2 Reference Name . W.13.2X4.16 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. STUCCO.0.25 0.25 0.05 0.05 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 14.41 4.87 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 14.41 x 0.85) + (1 / 4.87 x 0.15) = 0.090 Btuh/sf-F Total R -Value: 1 1 / 0.090 = 11.14 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 2 3R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 Reference Name . W.13.GARAGE Description .... Wall R-13 2x4 24oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.12 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 14.81 5.27 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 14.81 x 0.88) + (1 / 5.27 x 0.12) = 0.082 Btuh/sf-F Total R -Value: 1 / 0.082 = 12.17 sf-F/Btuh 'i CONSTRUCTION ASSEMBLY Page 3 3R Project Title.......... Cox Plan 1257 South Date........ 08/07/95 MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -FORM 3R User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 Reference Name . R.38.2X4.24A Description .... Roof R-38 2x4 24oc Type ........... Roof R -Value ........ 38 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description O. FILM. EX 1. SHNGL.CEMENT 2. BLDG.PAPER 3. PLY.0.50 4. AIR.RF.2.50 5c. BATT.R38.0 5f. FIR.2X4 6. GYP.0.50 I. FILM.IN.RF Exterior air film: winter value Asphault-cement shingles Building paper (felt) 0.50 in plywood 2.5 in (approx) air space: heat flow up R-38 batt insul (cavity > 11.25 in) 2x4 in fir framing 0.50 in gypsum or plaster board Inside air film: heat flow straight up Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Framing Cavity Frame R -Value R -Value 0.17 0.17 0.21 0.21 0.06 0.06 0.62 0.62 0.79 0.79 38.00 -- -- 3.46 0.45 0.45 0.61 0.61 40.91 6.37 Total U -Value: (1 / 40.91 x 0.93) + (1 / 6.37 x 0.07) = 0.034 Btuh/sf-F Total R -Value: 1 / 0.034 = 29.66 sf-F/Btuh HVAC SIZING Page 1 HVAC Project Title.......... Cox Plan 1257 South Date........ 08/07/95 Project Address........ La Quinta, CA Documentation Author... Carole Christensen, EA Company ................ Carole Christensen, EA Telephone .............. 1-800-735-8152 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 15 Building Permit Plan Check Date Field Check/ Date MICROPAS4 v4.02 File-COX1257S Wth-CTZ15S92 Program -HVAC SIZING User#-MP1017 User -Carole Christensen, EA Run-DD.78AC10.OR13.38.5.2 GENERAL INFORMATION FloorArea ................. Volume.. ..... ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1257 sf 10684 cf Front Facing INDIO 33.7 degrees 29 F 70 F 112 F 78 F 30 F Yes Yes Yes 0.20 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 11737 5924 Glazing Conduction ............... 4697 3895 Glazing Solar .................... n/a 1866 Infiltration ..................... 6300 3734 Internal Gain .................... n/a 3000 Ducts ............................ 2273 1842 Sensible Load .................... 25008 20259 Latent Load ...................... n/a 4052 Minimum Total Load 25008 24311 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. PHILIPS PRODUCTS 7/15/93 THERMAL TRANSMITTANCE VALUES ACCORDING TO NFRC 100-91 NOTES: (1) LOW E IS LOF ENERGY ADVANTAGE (2) FOR RESIDENTIAL PRODUCTS COMPARISON, THE USE OF 'AA' SIZE U -VALUE IS RECOMMENDED. (3) ARGON GAS OPTION NOT AVAILABLE IN CALIFORNIA AT THIS TIME. U -VALUE OVERALLIG' NFRC 100-91 SERIES THICKNESS":.. ALUMINUMA. ..FRAME:' CLEAR.&.:, LOW -E & STYLE (INCH): CLEAR ARGON LOW E ARGON.. AA BB K 1/2 x x 0.82 I 0.76 HORIZONTAL 112 x x 0.78 0.72 SLIDER 1/2 x x 0.72 0.66 1/2 x x 0.67 0.61 KN - 1/2 x x 0.84 0.78 HCR12ONTAL 1/2 x x 0.80 0.74 SLIDER 1/2 x x 0.75 0.68 1/2 x x 0.70 0.63 K 1/2 x x 0.E5 I i 0.79 SINGLE 1/2 x x 0.81 0.75 HUNG 1/2 - x x 0.75 1 0.69 1/2 x x 0.70 0.64 F -KN 1/2 x x 0.87 0.81 SINGLE 1/2 x x 0.83 I 0.77 HUNG 1/2 x x 0.78 0.71 1/2 x x 0.73 0.66 5/8 x x 0.61 0.59 5/8 x x 0.57 I 0.56 5/8 x x 0.50 0.418 K & KN 5/8 x x 0.44 I 0.43 PICTURE WINDOW I x x 0.58 0.57 1 x x 0.56 0.54 1 x x 0.46 0.44 1 x x 0.42 0.40 K5 & K6 5/8 x x 0.78 0.77 SLIDING 5/8 x x 0.75 0.73 CLASS 5/8 x x 0.67 0.65 DOOR 5/8 x x 0.63 0.61 NOTES: (1) LOW E IS LOF ENERGY ADVANTAGE (2) FOR RESIDENTIAL PRODUCTS COMPARISON, THE USE OF 'AA' SIZE U -VALUE IS RECOMMENDED. (3) ARGON GAS OPTION NOT AVAILABLE IN CALIFORNIA AT THIS TIME. INSTALLATION CERTIFICATE CF -6R The following is an explanation of many of the input values required on the opposite side of this form: HVAC SYSTEMS Heatlno Eouloment Tvnp- muct ha nna of tha fnllnw;nn- Furnace: Gas or oil -fired central furnaces & space heaters. Boiler. Gas or oil -fired boilers. PckoHeatPum : Packaged central heat pumps. S litHeatPum : Split central heat pumps. RoomHeatPum Room heat pump. Lr Pck HeatPum : Large Packaged Heat Pumps 05,000 Btuh output). Electric: Electric resistance heating HSPF=3.413. Radiant electric resist. heating HSPF=3.55 CombinedH dro: Reference water heater under water heating systems, below. meter to utu puoucation -Appliance ttttciency Hegulations', P400-92-029. CEC Cartlfled Manuf. Make & :Model Number; from applicable CEC appliance directory. Actual efficiency; from applicable CEC appliance directory. D/strlb type & location; Distrib type is "Ducts", 'Piping' or both. Duct location is 'Attic*, 'Crawlspace", -CVCcraw/space' or "Conditioned space" Piping location is to be listed as "Gond."or "Uncond. ". Duct or Piping R -Value; from the Directory Of Certified Insulation Materials and/or manuf's data. Heating Load Before Oversizing; refer to CEC -approved heading load calculation procedure. This is the hearing load result prior to application of the factor recommended in the load calculation procedure for oversizes the appliance to account for the use of a setback thermostat. Heating Equipment Capacity; from the applicable CEC appliance directory. Note; location elevations over 2000 tt above sea level require a derating of output capacity (refer to manufacturers literature). Coolino Eouloment Tvoe- must be one of thn fnllnw;nn- SolitAirCond, Split sstem air conditioner. PckoAirCond: Packaged air conditioner. SplitHeatPum : Split sstem heat pump. PckoHeatPum : Packaged heat purno. RoomHeatPum : Room heat pump. LgPckgHeatPump: Large Packaged Heat Pumps (>_65,000 Btuh output). Substitute EER for SEER when SEER is not available. RoomAirCond. Room air conditioner. Min. SEER varies' LrgPckgAirCond: Large Packaged Heat Pumps (', 6,000 Btuh output). Substitute EER for SEER when SEER is not available. EvapDirect: Direct Evaporative Cooling System. The SEER is fixed at SEER=11.0. The duct condition is to be fixed at location=attic and duct insulation R-value=4.2. Evap/ndirect: Indirect Evaporative Cooling System. The SEER is fixed at SEER=13.0. The duct. condition is to be fixed at location -attic and dud insulation R-value=4.2. - meter to Utu publication -Appliance Efficiency Regulations', P400-92-029. WATER HEATING SYSTEMS Dlstribution system Woe: refer to Residential Manual fnr mora rtotails Standard: Standard POU/HWR: Point of use/Hot water recovery Pioe Insulation: Pie Insulation Recirc/NoControl: Recirculation loop with no control Recirr-Tmer: Recirculation loop with a timer Recirc/Demand: Recirculation loop with demand control RecircvTime• Temp: Recirc. loop with timer and temp control Recirc/Temp: Recirculation loop with temperature I control The table below summarizes thn water haatinn cvctam itomc nooriad by watpr hpatnr tvnn Input item NAECA NAECA Storage Storage Gas or Oil Electric NAECA Heat Pump Instant. Gas Instant. Electric Large Storage Gas Indirect Gas Boiler Energy Factor Yes Yes Yes Yes Pilot Input, Btu Yes Yes Recov. Eft., fraction Yes Yes (AFUE) Standby Loss. % Yes Tank Volume, cal. Yes Yes Yes Yes Yes Tank Insulation. R Yes Yes Ext. Insulation, R Yes Yes Yes Yes Yes Additional Information Re ulred It Combined Hy dronic System: Rated Inout, kBtu Yes Yes Yes Rated Input, kWI Yes Yes Rec. Eff, fraction Yes INSTALLATION CERTIFICATE CF -6R Use of this form to satisfy the requirements of the Administrative Code Is optional, but the Information must be provided and posted. Site Address Permit Number An installation certificate is required to be posted at the building site prior to the issuance of the occupancy permit: this form may be used to meet these requirements. All appliance categories listed below are the actual equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better than the appliance specified on the certificate of compliance (Form CF -1 R). This certificate (or its equivalent) shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. Refer to the reverse side of this certificate for an explanation of information required. I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS: Heating Equipment Heating Equip. :CEC Certified Actual Distribution Duct or Heating Load Heating Type (Packaged Manuf. Make & Efficiency Type and Piping Before Over- Equipment heat pumo. etc) Model Number (AFUE. etc.) Location_ -Value Sizing (Btuh) C oacity fE!u.h Cooling Equipment Cooling Equipment Actual Type (Packaged CEC Certified Compressor Unit Efficiency Duct Duct heat pump, etc) Manuf. Make &Model Number LaEER)L _ Lac,, Qn R -value__ Signature, Date WATER HEATING SYSTEMS Distrito. Water CEC Certified Energy Tank System Heater Manuf. Make & Factor/ Volume I pe /# Model # Efiic. _1(aa Ions) HVAC Subcontractor (Co. Name) OR General Contras or OR G.vner Insul Internal Pilot Ratec Sc a.- Wrap .Wrap Insul. Standby Light . Input Wc.,c R-vn @ R -value Loss (%.) (Btuh l kW/Btu redi•: FAUCETS & SHOWER HEADS: All faucets and shcwerheads installed are listed in the Commissions Directory Of Certified Faucets And S^owerheacs. pursuant to T41e-24, Part 6, Subchapter 2, Section 111. Signature, Date Plumbing Subcontractor (Co. Name` OR General Contractor OR Owncr ` REPORT OF FIELD COMPACTION TESTS I CLIENT: OUR REPORT NO- i - ' DATE: PROJECT: NUCLEAR GAUGE INFORMATION AND DAILY STANDARD CALIBRATION NUMBERS VARIATION. PERCENT.+/- ' GAUGE ADJUSTMEVT TARIA_ ON FROM I CALIBRATION COUNTS FROM SHEM GAUGE TYPE TRO P, LL MOISTURE MOISTURE: MOISTURE: MOISTURE: MODEL NO_ I DENSITY: DENSITY'- DENSITY: DFNSfTY: PROCTOR WFORM,ATION SOIL 10 x VISUAL CLASSIFICATION OF SOIL MAX. DRY DENSITY. PCF OPTIMUM MOISTURE % I COMPACTION MOISTURE GENERAL LOCATIO`z! REQUIREMENTS, % REQUIREMENTS, TEST READING QUOTIENT/ SOIL TEST ELEVATION MOISTURE WET/DRY PERCENT COMMENTS NO. PCF. ID NO. DEPTH. IN OF TEST CONTENT. DENSITY. COMPACTION y, PCF M- , M - .. / Z ' ' % 1. • 13, D -s-, .. A IL p. u i i il TECHNICIAN: c COMMElfTS: 1 -FILL MAfERWL A- ES ITS COMPLY WITH SPEC:FICA TIONS 2 BACXFILL B -COM A ON PERCEMA" DOES NOT.FOMPLY WITH SPECIFICATIOkS 3 BASE COURSE C - RETEST OF PREVIOUS TEST '4 SUBBASE O MOLSTURE W EXCESS OF SPECIFICATIONS ' 5 SOIL CEMENT E- MOISTURE BELOW SPECIFICATIONS 6 >• OTHER Building Address Owner 52-198 Ave.. Martinez "William J. Cox & Sons 4 P.O. BOX 1504 No. 1 5223 78-495 CALLE TAMPICO LA OUINTA, CALIFORNIA 92253 Mailin Address 66900 Dilloun City Zip Tel. Desert Hot Sp i>ngs 92240 251-3780 Contractor Same Address City ZipTel.: State Lic. City & Classif. g 14'3957 1 Lic. # 2236 Designer Address CityI Zip I State Lic. # a LICENSED CONTRACTOR'S DECLARATION I J+ eby of V, Iha 1 -in licensed under provisions of Chapter 9 (commencing with Section A,ll)DO) of{Divisign 3 o the Business and Professions`Codeeand:mlicense is in full force and OWNER -BUILDER DECLARATION I hereby affirm that 1 am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, atter. Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rite a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build orimprove for the purpose of sale.) O 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) PalNo. Company Poll is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Dale Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is a building permit when properly filled out, signed and validated, and is subject to expiration If work thereunder is suspended for 180 days.. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city. to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST. OCC. GRP. P. Number Legal Description Project Description Approx. 125 1.f. of max. 32' retaining wall. With 125 1. f. o€ 6t high garden wall Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ 7i V Estimated Valuation $3,12S.00 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. 63.00 Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL 63.00 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line t Side Street Setback from Center Line Sine Setback from Property Line ,1DATE / INSPECTOR Issued bv:--/ Validated by: Validation: SETBACK SLAB GRADE FORMS FOUND. REINF. REINF. STEEL GROUT BOND BEAM LUMBER GR. FRAMING ROOFING VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL GARDEN WALL FINAL GROUND PLUMBING UNDERGROUND A.C. UNIT CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBIW FEES IST FL. SO. FT. ® $ 2ND FL. SO. FT. p POR. SO. FT. ® GAR. SO. FT. ® CAR P. I SO. FT. WALL SO. FT. SO. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation METER LOOP FLOOR DRAIN MECHANICAL FEES TEMP. POLE WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER' BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 VA c SEWAGE DISPOSAL SO.FT.GAR ® 3/ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK SLAB GRADE FORMS FOUND. REINF. REINF. STEEL GROUT BOND BEAM LUMBER GR. FRAMING ROOFING VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL GARDEN WALL FINAL GROUND PLUMBING UNDERGROUND A.C. UNIT ROUGH PLUMB. BONDING HEATING (ROUGH) SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK GAS (ROUGH) METER LOOP HEATING (FINAL) GAS (FINAL) TEMP. POLE WATER HEATER SERVICE FINAL INSP. WATER SYSTEM FINAL INSP.0/47 I FINAL INSP GRADING cu. yd. $ plus x$ REMARKS: A COLL. AREA STORAGE TANK ROCKSTORAGE OTHER APPJEOUIP. g6,.ar