SFD (0306-158)52810 Avenida Martinez
0306-158
LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
81314 B HI, ` 07131 12(
Date ` Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier fir- Policy No
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those. provisions:'
Date:: ; .f` -' 1 - Applicant;
Warning: Failure to secure Work r ompensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if I
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize ,representatives of this City to enter upon
the above-mentioned property for, -inspection purposes.
Signature (Owner/Agent) Date,
BUILDING PERMIT PERMIT#
DATE VALUATION LOT -A TRACT
P4 3 ELK 146
JOB SITE
APN
ADDRESS w-sio kwNwA mA>it'1 eaz
77$ -332 -MA
OWNER
CONTRACTOR / DESIGNER / EN (NEER
i?ovm I.W. NCE AW9.1, a4:`
131RAUC'KMAi3N BY9C '
P.t_l, BOX 134
PO B0J< 517
LA QLi11+T1A CA V2w53
LAQT:fl;IA CA 92353
USE OF PERMIT
106 IF. S;i►i'3 PI1"IT DOM NOT INCLUDE B!JXK WAL.l, P001.
DRIVYWAY APPROACH
'TRACT COMf3TRUCTION 1.4M.0 3F
7O'PLMPATTO - r.00:'
0AI AtSMARPORT MIX ?!'
Wrm"I7w CWT or COXIMRUCI SON
o
FMIK I' 71M Ma"RY
vt A1Si'11UG71c F4ni 10), _000-4.1 -10-(W M-00
ALAN CHtCX Mt 1 tai-{3 i{ 31 it d41,ff7
F£ DR:POSXT VD1 -43 4-318 •3 .t
(1GktCNANICJkL M 101-00"20-c<* 0150
EL1 Q."t'MAL M ML%
PLJMi3M l 1 Ck 1- {iii)• -•c t 9.000
M
8 TRG:gt! MOT10N FIM - RDID 1014M -2414M
GRADiT O !EE 101 •G`Csii- ti i + I.i.pit
D9VILOM91;1!€rACT F0 7,41iS, Q
PRACISVIPIAW 10'-00441—U3 441—U3 $.100.w .
SM. TOTAL t' J1ZWUC'"i10; z . PT. Ai4 C'.11PCK
p a IS PTZE-PAW M3
425000
JUN 19 2003 l rOTM.,.F'.rmrrF .0ur.NOW
s3,&MA7
CITY OF
F NAN E DPNrTA
Etf
RECEIPT
DATE' /
BY(':
DATE FINALED
INSP T
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
- / O
Exhaust Fans
O.K to Wrap
0—T
F.A.U.
Framing
Compressor
Insulation
—Q
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
2.
Drywall - Int. Lath
Final
Final "tee
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
O
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer ConnectionEncapsulation
I
Gas Piping
Gas Test
O 3
Appliances
Final
Final
Utility Notice (Gas) i
ELECTRICAL APPROVALS
Temp. Power Poleaa,2Q
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power p Q3
Final 10.2
Utility Notice (Perm) D01
COMMENTS: p
I TS
�—
��
30 • X58 4 4 "
P.O. BOX 1504 APPLICATION ONLY
Building 78-495 CALLE TAMPICO
Address 5,7,:310 f U L 1*2Tf/£7__. LA QUINTA, CALIFORNIA 92253
Mailing
Address'po 13 L.,
City a Zip Tel.
Vr ctor
,l
S'/ `% t
`--a-1,: I /'1 111$.-9-l6y
State Lic./ I City
& Classif.'V 9 Lic. #
Arch., Eng Designer Q '(4
Address Tel.
98 IZ.O i( <$4AWO Zarb 260 !;-(o
X70 7
Ci y Zip 3 State
PPyy Lic. #
—-VCENSE DECLARATION
that I am I' under provisions of Chapter 9 (commencing with Section
'ray t s' and Professions Code, and my license is in full force and
OWNER -BUILDER DECLARATION
I he
affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5.Business and Professions Code: Any city or county which requires a
permit to construct, alter. improve, demolish, or repair any structure, prior to 'its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
I: I, as oner of the property, or my employees with wages as their sole compensation, will
do the wowrk, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
Provided that such improvements are not intended or offered for sale. If, however, the building
orimprovement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I 1 I, as ownerof the property, am exclusively contracting with licensed contractors to con.
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
i! I am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
fl Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or lass.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
1hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above.
mentioned property for inspection purposes.
Signature of a0plicant Date
Mailing Address
City, State, Zip
BUILDING: TYPE'CONST. SF0 OCC. GRP.
A.P. Number '775' -3-3.2- /
U0 7
Legal Description t -I L3 RC, /V"
Project Description
Sq. Ft. / No. No. Dw.
Size y b Stories Units
New ❑ Add ❑ Alter O Repair ❑ Demolition ❑
Estimated Valuation
PERMIT AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback ,frofro P operty=L--ine.
FINAL DATE ttr( "INSPECTOR'-
Issued by: Da''ttlfAR Rerm
- I ► t r 11
Validated by: I
ClT1 F"'
Validation: Fer,r, •. ! O
WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.14 X 1,436 S.F. or $3,073.04 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By C/C Valley Independent Bank - Mike Check No. 287260
Name on the check Telephone 485-9269
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected
Signature
$3,073.04 So.00
Payment Recd Over/Under
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
CERTIFICATE OF COMPLIANCE
J F sc
Desert Sands Unified School District
47950 Dune Palms Road
z °
C BERMUDA DUNES
Date
6/16/03
`, q
La Quinta, CA 92'253
RANCHO MIRAGE b
INDIAN WELLS
No.
24550
(760) 771-8515
-
ALM DESERT y
i^P LA QUINTA
-
V.? IND19
YYY YJ
O
Owner
Power Finance Assoc. Inc.
APN #
773332004
Address
P. O. Box 134
Jurisdiction
La Quinta
City
La Quinta . Zip 92253
Permit #
0306-158
Tract #
BLK146
Study Area
Type
Single Family Residence
No. of Units
1
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1 23
52810 Avenida Martinez
1436 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.14 X 1,436 S.F. or $3,073.04 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By C/C Valley Independent Bank - Mike Check No. 287260
Name on the check Telephone 485-9269
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected
Signature
$3,073.04 So.00
Payment Recd Over/Under
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
SOLITHLAND TITLE
March 12, 2003
Escrow Officer:
Escrow No.:
Title Order No:
Title Company:
Rodney Slagle
IN3891-RS
859189
First American Title
GL -10010 Ave. M4f apz
Escrow Division .
45110 Club Drive #8 Suite B
Indian Wells. CA 92210
Phone (760) 345-555/ Fax (760) 345-2217
RSlagle@southlandbUe.com
YOUR COPY
Property Address: Vacant Land APN #773-332-003; 0-004 0 La Quinta, CA 92253
FIRST SUPPLEMENT TO VACANT LAND PURCHASE AGREEMENT AND JOINT ESCROW INSTRUCTIONS
(AND RECEIPT FOR DEPOSIT) BY AND BETWEEN PFA Inc., A California Corporation, or Assignee, AS
BUYER AND Mary E. O'Connor Revocable Trust AS SELLER, DATED March 7, 2003.
CONFIRMATION OF PURCHASE TERMS:
CASH DOWN PAYMENT: $101,86.00
(of which the sum of $5,000.00 will be deposited into escrow
TOTAL PURCHASE PRICE: $107,800.00
CONFIRMATION OF ACCEPTANCE DATE: The undersigned Buyer and Seller hereby confirm the acceptance
date of the above referenced agreement as March 10, 2003.
OPENING OF ESCROW: The opening of escrow is March 12, 2003
CLOSE OF ESCROW: Pursuant to the terms of the above referenced agreement, the close of escrow shall occur
on/or before April 25, 2003
ESCROW HOLDER ACKNOWLEDGEMENT: Buyer and Seller herein acknowledge that Escrow Holder shall act
in accordance with Paragraph 31 JOINT ESCROW INSTRUCTIONS TO ESCROW HOLDER, subject to the
following;
• Escrow Holder shall NOT be concerned nor liable with items referenced in Paragraph 27.
• In addition to copies of the Original Purchase Contract, Escrow Holder has received NO counter offers
and/or Addendum. Escrow Holder shall only be concerned with the following items, which items are not
covered by Paragraph 31 as stated above: N/A
FEE TITLE: Fee title to the property subject of this escrow is vested in: Mary E. O'Connor, Trustee of Mary E.
O'Connor Revocable Trust The undersigned Seller(s) amend the Vacant Land Purchase Agreement and Joint
Escrow Instructions (and Receipt for Deposit) to provide for the above referenced vested parly(iesYentity as the
Sellers.
BUYER SHOWING TITLE VESTED IN: PFA Inc., A California Corporation, or Assignee
(Buyer's vesting to be handed to Escrow Holder with signed escrow.iristnfictions. Said vesting shall be inserted
on the grant deed even though said deed has been prepared, signed and notarized by and on behalf of the sailer
named herein. THE MANNER OF TAKING TITLE MAY HAVE SIGNIFICANT LEGAL AND TAX
CONSEQUENCES.)
LEGAL DESCRIPTION: The legal description to the subject property is
CL`o 2 and 24 of Block 146 of Santa Carmelita at Vale La Quinta, Unit No. 15, in the City of La Quanta,
County of Riverside. State of California, as per map recorded in Book 18, Page(s) 92 of Miscellaneous
Maps, in the office of the County Recorder of said County.
Z A 6 9 Z 9 ' 0 N
N]JJn9 WVI111M WV69:L EOOZ A 'AeW
RC DISTRICT - PLANNING REVIEW FORM
This form is to be used by CDD staff for review -of single family dwellings in the. RC' (Cove
Residential) District per Section 9.50.090 of the Zoning Code. Its purpose is to determine: 1)
that the proposed housing design does not duplicate the same architectural style of any house
within 200 feet of the applicant, and/or 2) if there is a need for the applicant to file for Master
Design Guidelines. If the applicant does need to file a Master Design Guideline, please transmit
this information to the Building and Safety Department as part of your correction list. Please
attach additional explanations as necessary.
APPLICANT:
SITE ADDRESS: 5 z Flo
APN 7T -3: J - 004
LEGAL: LOT c 3 BLOCK
V
CASE NO.: g
iP UNIT IS— S.C.@V.L.Q.
CHECK AND APPROVED BY: -DATE: 5-/2i/03
Inform the assigned Building plan checker upon your assignment to this case. The CDD
Executive Secretary maintains a log book to track applications and assign case numbers.
REQUIRED ITEM
Y
IN
COMMENT/CORRECTION
Verify legal and APN information
v , y o„,, , R is ,q,,,►,,`«_
Consistent with MDG on file (as
applicable)
MDG filing required (5 filings
since 9/3/98)
Architectural variety within 200
feet of the surrounding area:
Architectural design features
D
roved eso
Plonning CommissionUlf
ni
...__...
ommunity Dev. Dept S o
ials *..,.__.,,.,,. .._...
L"--,
C
Ex
se No. dc. vs -81.8
i1bit
Ahth Conditions,
mac- r
Other Requirements:
UCI-17-2003 07;13 AM
CAT pF FIELD VERIFICA
Prolmcl Till
ProjeC AAcIgrG6s
BUildef Con11C I
HERS ' Tel• hone--
---------
. % ,
Too e
C Ing Signature
Irm; Dat
SOGJ
P. 10
90 C F -411
+pIC
I V
Bullder Name
Plan Number ___-
Sample Group Number
sample House Number
HERS Provider: G
Strcet Address- 7 /
Copies to.
o Builder, HERS Provider Clly/Slate/Zip: G y
HE RA?' OMP ANC TATE
The house was: LNY
Tested ❑ Apprcved as part of sample lest, but was not tested
As the HERS rater providing diagnostic testincl and field verification, I certify that the houses identified co ly with the diagnostic testedOslIc compliance •e uir
Distribution system is fully ducted (I,s, C0e ementb as checked on this form, fled on this form
of ducts) , s not use building cavities as plenums orI
Where cloth backed, rubber adhesive tit. ct taeinstalled, P atform returns In lieu
with cloth backed, rubber adhesive duct ape to 6081 leaks a duct connOcz drew ere used in combination,
ted MINIMUM REQUIREMENTS
':OR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
duct Diagnostic Leakage Testing Results (N'axfmum 6% Duct Leakage)
Cuct Pressurization Test Results (CFM @ 25 pa
Measured
values
Test Leakage Flow in CFM
If fan flow is calculated as 400cfm t n x number oft ns neer
calculated value here /
If fan flow is measured enter measured value here
Leakage Percentage (100 X Test Leakage/Fan Flow) _ o
Check Box for Pr se or Fail/o
Passm o J
( t3 or less)
Fqal
lNSIOALVETXV'THERMOSTATIC EXPA'
orCoiwrission approved a nZes
❑ No Thermostatic Expansion VttivetOT
equivalenr)•Is installed and Access Isprovidedfopnspection
d MINIMUM RYes IS 8 pass
EQUIREMENTS FOR DUCT DESIGN COMPLIANCE CRIEl
1 Yes O No ACCA Manual D Deslg' re
CF -1R quirements have been met
(rater has verified th 3t actual installation matches values in
and design 01 plan.
2 O Yes p No TXV Is installed or F,tn flow has been verified. I
verified fan flow rhatt:hes design from CF -1 R f no TXV,
Measured Fan Flow
Yes for both 1 and 2 is a Pass
a
PaSs Fail
11
lLllhf
O q
Pass Fa i;
E A 601Z'ON NHJH WdIIIIM Wd££:Ol U0Z 'N'100
JUL 21 '03 15.29 FR
r ; Infonwhon
oTo Budd On .
Engineering • CansaM/ng•• Testing
TO 9-7777011 P.04i07
REPORT OF FIELD COMPACTION TESTS
TESTED FOR: POIKER FINANCE PROJECT: 52810 AVE MARTINEZ
PO BOX 134 LA QUZNTA, CA
LA QUINTA, CA 92253
DATE: July 03, 2003 OUR REPORT NO.: 073-30261-2
TEST DATA: (1) Fine to medium grained silty sand w/ agg. OPT. MOIST. = 10. 591
TEST
NO.
TEST
DEPTH
ELEVATION
SOIL 10
NUMBER
MAXIMUM
LAB ORY *
DENSITY
WATER
CONTENT
VIET
DEtISrrY
DRY
DENSITY
PERCENT
COMPACTION
COMMENTS'
Spec. 90$ Min
1
8"
FG
1
122.0
7.7
1::0.6
112.0
91.8
1 - A
.2
8"
FG
1
122.0
8.2
I 1:'.1.9
1 112 _ 7
92.4
1 - A
3
811
FG
1
122.0
7.9
1:14.7
115.6
94.8
11 - A
4
811 —
_FG —
i 1
122.0—
- 9.1 —
1_:0.1
110_1
90_2
.1 _ A
, I
TEST LOCATION: House pad -- 52-810 Ave Martinez
1 NE corner of pad
2 SE corner of pad
3 SW corner of pad
4 Nw corner of pad
NOTES: TESTS PERFORMED PER ASTM X2922-96 8 ASTM 03017-96 "COMMENTS: 1. FILL MATERIAL A, TEST RESULOTS COMPLY VITTISPECIFIC,%IONS
DENSITIES SHOWN: LbS. per cubic foot 2. BACKFILL B. PERCENT C IMPACTION DOE NOT COM LY
WATER CONTENT: Percent of dry weight. 3. BAS$E COU ISE WITH SPECIFICATIONS
PERCENT COMPACTION: Based on maximum dry 4. SU88ASE C. RETEST OF PREVIOUS TEST
soil ID number led on sample indicated by 6: OTHEREME NT E. MOISTURE BLOwPECIFSCATION$ATIONS
+ (1) ASTM D1557-00 METHOD A
TEST INSTRUMENT:
REMARKS: PSI did not monitor the material placement
TECHNICIAN: Juan Nunez
THESE TEST RESULTS APPLY ONLY TO TIIQ SPHCIFIC LOCATIONS NOTED AND MAY NOT REPRnNr ANY OTHER LOCATIONS OR ELEVATION;.
REPORTS MAY NOT BE REPRODUCCO. CXCCPT IN rVLL. MtHOVT wRITTP.N PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC.
STANDARD COUNT M; 01.
ADJUSTMENT DATA M: D:
Respectfully submitted,
Professional Service Industries, Inc.
Professional Service Industries. Inc. • 42-240 Green Way, Suite C • Palm Desert, CA 92211 • Phone 760/341.5790 • Fax 760/$41-5794
PrI A-100.2 (4M
/
CITY OF LA QUINTA SUB -CONTRACTOR LIS -
JOB ADDRESS
This form shall be posted
PERMIT NUMBER OWNER vj BUILDER 1?1Wa4 qq �G,
Inspection
on the iob with the Building
Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement
of building permit.
of work. Failure to comply will result in a stoppage of work and/or the voidance
For each applicable trade; all information requested below must be completed by applicant. "On File" is
Trade / Classification Contractor
not an acceptable response.
State Contractor's License Workers Com ensation Insurance I
MASONRY IC -29)
PLUMBING (C-36)
/9%
C. 3b
City Business License
7 �/ c,
3r Oy
3/ d�
Q?S01/0r O Y
C.A�i.`tif� �li�lC`%� �� 3// O
�oldeu s iYw _V I102 tf/ 03
y,
s/ -mac y�-Go/z�.�� �•; y
Company Name
assification
:(e.g.A, B, C-8)
License Number
(xxxxxx)
Exp. Date Carrier Name
(xx/xx/xx) (e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
License Number
Exp. Date
EARTHWORK (C-12)
.f
'n2'c��
0303
3i�3
Dl
(C739)
(xx/xx/xx)
(xxxx)
(xx/xx/xx)
46
��
L 0/0'?
0� �74T,f F'o
�y�1 ` Doi 5799
Io1Oz
0076z�
3
CONCRETE (C-8)
�%1�$ryt�'j' L11 �i
r
0 k —Jcr
N 2.S /
g ,�l o �Ji; e LCA ��•T I
/ ��C�
Uq )
c�� �/
o o s o
%O_,o
aZ 38 7
FRAMING (C-5)
li{f{j A4001AtGi T0N
6
G? 2 901
t 2 3! 03 r � (ZVN%/
z / 0o/ %S%
03
r�'r-W U7(/ Wl� L02 '-2• /0 27 �3 C>,3OE.�
S q o�
CABINETS (C-6)
STRUCT STEEL (C 51)
&
MASONRY IC -29)
PLUMBING (C-36)
/9%
C. 3b
-2,5 1 -7
5P.5,9
z.s2s Y3
zs2 (,5
�yg3�z
7 �/ c,
3r Oy
3/ d�
Q?S01/0r O Y
C.A�i.`tif� �li�lC`%� �� 3// O
�oldeu s iYw _V I102 tf/ 03
y,
s/ -mac y�-Go/z�.�� �•; y
00S0
/3 %
o��s�
'
�j; oy-
LATH, PLASTER (C-35)
DRYWALL 0)
HVAC (C-20)
ELECTRICAL IC -10)
�o so o
leko
l)IfV I OPI* Ala
c 2 33'
e z- q 3s
[r l C
g/
SU?r3 i
a aZ
/_0
OROOFING
0303
3i�3
Dl
(C739)
9iCJZ•J/y�
9
S%�-r✓
5 ¢� Fogg
0b01%
o 6sz>
/%`�GLAZING
y .
03SHEET
�'
03 M(-
METAL (C-43)
FLOORING (C-15)
IC -171
INSULATION (C-2)
SEWAGE DISP. (C-42)
r
0 k —Jcr
2
y 23/0
O��y3
33�t//
O 0?—
X XW17
1.3
1�%62-0�
%LTC 6 1u04�00
%O_,o
aZ 38 7
5;R o1C,
1(0/11/01/
PAINTING (C-33) �
CERAMIC TILE (C-54) .
2S>7) -Yl? i� f�Z
r�'r-W U7(/ Wl� L02 '-2• /0 27 �3 C>,3OE.�
CABINETS (C-6)
FENCING IC -13)
LANDSCAPING (C-27)�
,/ �
,
B
68z�o/
I 03
5%/t'rfi /Nf% LZ�'/
DD� T 78% %
0 0,3
/'% 0,3 Ci�
POOL (C-53) .
I
3 Cert:fca to h{ rf Occut J
of 9 Bu l.:ding & Safet rDe 3 aiinen
Y
This Certificate is issued pursuant; to the re' uiremenas of, Section 109 of fhe'Cali
-_ . ,..q w forma Budding=
Code,.cert fying 'that; ''at the:: time ofissuance, this structure .:ivas, in,
' com "/lance with. the
p, u.,
provisions. -of. fhe Building Code and fhe` var ors "ordinances of the Ci,comp,
y regula`tg budding
F
construction: and/or use -
i -F
BUILD:ING ADDRESS..; 52 `810 AVE'NIDA MARTINEZ
+
. e .' ° '-!. r '. • fir` .%-' •r. r ` i .. - c . .. .
.j
r, Use -classification SINGLE':FAMILY DWELLING° Building Permit No 0306 1:58.
f Y
Occupancy Group R-3 r ' Type of Con"struction VN Lan Use Zone RC
Owner of Building. POWER:FINANCE ASSO:C4IATES INC. Address 'P:O ;BOX X134
City;=ST,ZIP 'LA QUINTA.:CA.92253;n
'By KIRK,-KIRKLA`Wb` r
-Date Octob6r',24,"20.0:3 y
'Building Official ry
,Po0-J 'A:;CON§0-IC000S..PLACE
- ;-
TITLE 24 REPORT
Title 24 Report for:
Thomas Buffin
San Felipe 4 bed. - All Orientations - Tower
La Quinta, CA
Project Designer:
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE -per BYG
Report Prepared By: oC-Qcg
Joan D. Hacker
Insu-form, Inc.
68-255 Corta Road
Cathedral City, CA 92234
(760) 324-2046
Job Number:
Date:
5/14/2003
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655
I TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Checklist 6
Form C -2R Computer Method Summary g
HVAC System Heating and Cooling Loads Summary 12
Room Load Summary 13
EnergyPro 3.1 By EnergySoft Job Number. User Number 2655
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Thomas Buffin 5/14/2003
Project Title Date
San Felipe 4 bed. - All Orientations - Tower La Quinta
Project Address Building Permit #
Insu-form, Inc. (760) 324-2046 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 1,436 ft2 Average Ceiling Height: 9.0 ft
Total Conditioned Slab Area: 1,436 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑Raised Floor
FENESTRATION
Chnrlinrr, nnioin
Type Orientation
Area
SF
Const.
Fenestration
SHGC
Component
Frame
Assembly
Location/Comments
Type
Type
U -Value
(attic, garage, typical, etc.)
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
R-13 Wall w/1" EPS
Wood
0.059
Exterior Wall
Solid Wood Door
None
0.387
Exterior Door
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
FENESTRATION
Chnrlinrr, nnioin
Type Orientation
Area
SF
U -Factor
Fenestration
SHGC
Exterior
Shading
Overhang Side Fins
Yes / No Yes / No
Front
24.0
0.75
0.62
Bug Screen
X❑ ❑
❑ X❑
Left
28.5
0.74
0.62
Bug Screen
Q ❑
❑ X❑
Rear
40.0
0.78
0.63
Bug Screen
X❑ ❑
❑ X❑
Rear
49.0
0.75
0.62
Bug Screen
0 ❑
❑ X❑
Right
30.0
0.75
0.62
Bug Screen
X❑ ❑
❑ X❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
El' El
El El
Run Initiation Time: 05/14/03 22:07:55 Run Code: 1052975275
Ener Pro 3.1 By Ener Soft
User Number: 2655
Job Number:
Page 3 of 13
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Thomas Buffin 5/14/2003
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and' Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
Central FnrnarP 80% AFUE Ducts in Attic 42 Setback Living Zone
Cooling Equipment Minimum
Type (air conditioner, Efficiency
heat pump, evap. cooling) (SEER)
Duct
Location
(attic, etc.)
Duct
R -Value
Thermostat Location /
Type Comments
Split Air Conditioner 12.0 SEER
Ducts in Attic
42
Sethack
I *v*nq 7nne
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Fact! 1 External
Water Heater Water Heater
Distribution
# in Input
Cap.
or Recovery Standby Tank Insul.
System Name Type
Type
Syst. Btu/hr
(gal)
Efficiency Loss (%) R -Value
A.O. SMITH FPS -50-224 Small Gas
Standard
1 43.000
50
0.60 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm:
Address:
Telephone:
Lic. #:
(signature)
Enforcement Agency
Name:
Title/Firm: _
Address:
Telephone:
(date)
Documentation Author
Name: Joan D. Hacker
Title/Firm: Insu-form, Inc.
Address: 68-255 Corta Road
Cathedral City, CA 92234
Telephone: (760) 324-2046
ul
o - (" \,
(sign ur) V I 1(dAte)
IEnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 13 1
Certificate of Compliance: Residential (Addendum) CF -1 R
Thomas Buffin 5/14/2003
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
)ased on the adequacy of the special justitication and documentation submitted.
Plan I Field
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R.Plate
The HVAC System "Living Zone" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 05/14/03 22:07:55 Run Code: 1052975275
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 13
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
"§150(.): Minimum R-19 ceiling insulation.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
1150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
not apply to exterior mass walls).
"§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑ Gas Logs.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
a§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA.
§ 150(1): Setback thermostat on all applicable heating and/or cooling systems.
1V1 1 §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined intemal/extemal insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 13
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk
(") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
X❑ "§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas,, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
a§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
FRI§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 13
Computer Method Summary (Part 1 of 3) C -2R
Thomas Buffin 5/14/2003
Project Title Date
San Felipe 4 bed. - All Orientations - Tower La Quinta
Project Address Building Permit #
Insu-form, Inc. (760) 324-2046
Documentation Author Telephone Plan Check/Date
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer) Cimate Zone
Source Energy Standard
Facing
❑
Facing
D.00>- 24 -0_38Z 90
Facing
Facing
Wa11_ 302 0.059 go 9.0_ 1
Use (kBtu/sf-yr) Design
North Margin
R-13 WaILw/1" EPS living Zone
East Margin
South Margin
R-13 Wall w/1" EPS living Zone
West Margin
0
1.03 0.68
1.59 0.12
1.83 -0.12
1.21 0.50
Space Heating 1.71
Space Cooling 35.52
34.89 0.63
34.80 0.72
33.20 2.32
36.34 -0.82
Domestic Hot Water 16.25
1 14.05 2.20
14.05 2.20
14.05 2.20
14.05 2.20
49.97 3.51
50.44 3.04
49.08 4.40
1.88
Totals 53.48
BUILDING
COMPLIES
This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence.
This plan has been analyzed with identical features in all orientations. ❑X Slab Floor
GENERAL INFORMATION
Conditioned Floor Area: 1,436 Floor Construction Type: ❑ Raised Floor
Building Type: Single Fam Detached
Building Front Orientation: All Four Orientations Total Fenestration Aea: 11.9%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 12,924
Number of Stories:
Slab Floor Area: 1,436
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
livingZone1 436 12 92dQ2d 1 nn Conditioned- Retbark 2 -n/a
OPAQUE SURFACES Solar
Act. Gains
Type Area U -Val. Azm. Tilt Y / N Form 3 Reference
Location / Comments
Wall 122 _0_05k a 3Q
❑
R--13 Wall w/1" EPS living Zone
D.00>- 24 -0_38Z 90
Solld-Wood.DAor .Living Zone
Wa11_ 302 0.059 go 9.0_ 1
Ali❑
R-13 WaILw/1" EPS living Zone
Wall_ 271 0.059 180 90
❑
R-13 Wall w/1" EPS living Zone
Wall- 330 0.059 270 _90
RODL 1 436 0.028_ 270 0
0
❑
❑
R-13 Wall w/1" EPS 1 iving lone
R_38 Roof (R38 2x1416) living -Zone
❑❑
❑❑
❑❑❑
Run Initiation Teme: 05114/ n C • 1052975275
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 13
Computer Method Summary (Part 2 of 3) C -2R
Thomas Buffin 5/14/2003
Project Title Date
FENESTRATION SURFACES
U_ Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
J_
Window Front M01th)
24.0_
_0.750
_0_62
0_ _90 WesLQoast_Wjndows
-Living
2
Window Left (East)
12.5
0.740
0.62
90 90 West Coast Windows
Living Zone
3
Window Left East _
16.0
0.740
0.62
90 90 West Coast Windows
Living Zone
4
Window Rear (South)
40.0
0.780
0.63
180 90 West Coast Windows
Living Zone
5
Window Rear (South)
9.0
0.750
0.62
180 90 West Coast Windows
Living Zone
6
Window Rear (South)
20.0
0.750
0.62
180 90 West Coast Windows
Living Zone
7
Window Rear (South)
20.0
0.750
0.62
180 90 West Coast Windows
Living Zone
8
Window Right (West)
24.0
0.750
0.62
270 90 West Coast Windows
Living Zone
5
Win ow Right est)
6.0
0,750
0.62
270 _90 West Coast Windows
living Zone
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
4.0
6.0
2.0 0.1 2.0 2.0
2
Bug Screen
0.76
5.0
2.5
2.0 0.1 2.0 2.0
3
Bug Screen
0.76
4.0
4.0
2.0 0.1 2.0 2.0
4
Bug Screen
0.76
6.8
6.0
2.0 0.1 2.0 2.0
5
Bug Screen
0.76
3.0
3.0
2.0 0.1 2.0 2.0
6
Bug Screen
0.76
4.0
5.0
2.0 0.1 2.0 2.0
7
_iF
Bug Screen
0.76
4.0
5.0
2.0 0.1 2.0 2.0
Bug Screen
0.76
4.0
6.0
2.0 0.1 2.0 2.0
9
Bug Screen
0.76
3.0
2.0
2.0 0.1 2.0 2.0
Run Initiation Time: 05/14/03 22.07.55 Run Code: 1052975275
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:9 of 13
Computer Method Summary
Minimum Distribution Type
(Part 3 of 3) C -2R
Thomas Buffin
Efficiency and Location Duct Thermostat
5/14/2003
Project Title
Comments
Date
THERMAL MASS FOR HIGH MASS DESIGN
Living Zone
Area Thick. Heat
Inside Location
Type (so (in.) Cap.
Cond. Form 3 Reference
R -Val. Comments
PERIMETER LOSSES
System Name Length
Diameter Thick.
F2 Insulation
Type Length Factor R -Val.
Depth Location / Comments
Slab Perimeter 53 0_76 0.0
0 Livin Zone
-
Sl.ab-Berimeter 15 _4.Zf --0-0.
0 Living Zone
Comments
HVAC SYSTEMS
Heating Equipment
Minimum Distribution Type
Type (furnace, heat
Efficiency and Location Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Ce ral Furnace
80% AFUE Ducts in Attic 4.2 Setback
Living Zone
Pipe Insul.
Hydronic Piping Pipe
System Name Length
Diameter Thick.
Cooling Equipment
Minimum Duct
Type (air conditioner,
Efficiency Location Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER) (attic, etc,) R -Value Type
Comments
Split Air Conditioner
12,0 SEER Ducts in Attic 4.2 Setback
Living Zone
WATER HEATING SYSTEMS
Ratedl Tank
Energy Fact! 1 Tank Insul.
Water Heater
Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name
Type Type Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
A.O. SMITH FPS -50-224
Small Gas Standard 1 43.000 50
Q_U— _/a_ n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters
(rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 05/14/03 22.07:55 Run Code: 1052975275
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 10 of 13
Computer Method Summary (Addendum) C -2-R
Thomas Buffin 5/14/2003
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement aaencv determines the adeauacv of the justification, and may reject a building or design that otherwise complies
)ased on the adequacy of the special justification and documentation submitted.
HERS Required Verification
Thoeo foaturoc mutt ho ennfirmpd and/or tested by a certified HERS rater under the supervision of a CEC aaaroved HERS
Plan I Field
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R.
Plan
Field
The HVAC System "Living Zone" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
EnerovPro 3.1 By EnergvSoft User Number: 2655 Job Number: Page: 11 of 13 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
Thomas Buffin
DATE
5/14/2003
SYSTEM NAME
Living Zone
FLOOR AREA
1,436
Number of Systems 1
Heating System
Output per System 92,000
Total Output (Btuh) 92,000
nutnut (Rtuh/saftl 64.111
Cooling System
Output per System
48,000
Total Output (Btuh)
48,000
Total Output (Tons)
4.0
Total Output (Btuh/sqft)
33.4
Total Output (sgft/Ton)
359.0
Air System
CFM per System
1,595
Airflow (cfm)
1,595
Airflow (cfm/sgft)
1.11
Airflow (cfmrron)
398.8
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS
26.0 OF 69.3 OF 69.3 OF
Outside Air
0 cfm
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG. PEAK
PCCOIL
FM
Sensible
Latent
CFM
I Sensible
1,317
24,545
3,139
421
23,646
0
1,227
1,182
0
0
0
0
01
0
0
0
0
1,227
1,182
26,999 3,139 26,011
BDP CO. 563AN048-A
u
32,172
11,035
Total Adjusted System Output
Ad' t d for Peak Desi n Conditions)
32,172 11,035
92,000
92,000
( ls e g
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
yam Temperatures at Time of Heatinq Peak)
123.5 OF
Supply Air Ducts
122.8 OF
Supply Fan Heating Coil
1595 cfm ROOMS
70.0 OF
69.3 OF
in Return Air Ducts "I
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.9 / 77.6 OF 78.7 / 65.8 OF 78.7 / 65.8 °F 59.8 / 58.7 OF
O4 Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 60.5 / 59.0 OF
1595 cfm 52.0% R.H. ROOMS
78.7/65.8 °F 78.0 / 65.6 OF
User Number: 2655
Return Air Ducts
Job Number.
12 of 13
ROOM LOAD SUMMARY
PROJECT NAME
Thomas Buffin
DATE
5/14/2003
SYSTEM NAME
Living Zone
FLOOR AREA
1,436
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LivingLiving Zone
1
1,317
24,545
3,139
1,317
24,545
3,139
421
23,646
PAGE TOTAL
TOTAL
1 1,317
24,545
3,139
421
23,646
1 1,317
24,545
3,139
421
23,646
EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page: 13 of 13
52-810 Ave-, ^ANTI sj, .
TRU,SSWOR S"
A C a n Truss!
CI OF QUINTA
BUILDING & SAFETY DEPT.
APPROVED ,
FOR CONSTRUCTION
+ DATE l BYS
75-110 ST. CHARLES PLACE
SUITE 11A JOB NO.: g 3 25 3
PALM DESERT, CA 92260
PHONE: 760-341-2232 • FAX: 760-341-2293 NAME:
MANUFACTURING YARD: PROJECT: N Ft -L 1 P15
55755 TYLER STREET, THERMAL, CA 92274
FAX: 760-399-9786 {
r
TRU,SSWOR S"
A C a n Truss!
CI OF QUINTA
BUILDING & SAFETY DEPT.
APPROVED ,
FOR CONSTRUCTION
+ DATE l BYS
75-110 ST. CHARLES PLACE
SUITE 11A JOB NO.: g 3 25 3
PALM DESERT, CA 92260
PHONE: 760-341-2232 • FAX: 760-341-2293 NAME:
MANUFACTURING YARD: PROJECT: N Ft -L 1 P15
55755 TYLER STREET, THERMAL, CA 92274
FAX: 760-399-9786 {
NATIONAL INSPECTION ASSOCIATION, INC.
Inspection of Prefabricated Trusses / Quality Audited by AA -583
PLANT DATE/ARRIVE/DEPART
ADDRESS PLATE MANUFACTURER _7,R(,L5W l
PLANT CONTACT F , Ue_ ENGINEERS DES. DWG. IRRQa . `1%1P, 5'emee
N heduled In Plant Audits As Per Uniform Building Code Section 23 nd
IBC Section 2303.4 or Newest Sectionsn, and In Accordance With Engineered Plan Specifications.
CATEGORY
CONFORMING
NON -CONFORMING
REMARKS
Lumber Grade
Connector Plates I I.C.B.O.
d
Span & Pitch
Workmanship
Joint Accuracy
Ce
Bearing of Wood Joints
Knots in Plate Area
Split Limitation
Plate Placement
Plate Size
d
Condition of Plate Teeth
Plate to Wood Tolerance
In -Plant Handling
06
Bundling & Loading
0619F
Storage
C
Jig & Press Adequacy
Marking Legibility
d
Plant Stamp Verification
How Many Stamps On Site: W
Trusses Meet UBC & IBC Requirements
e
i
In -Plant Q.C. Records
As Per ICBO/ES Requirements .
d
A
10-7-8
Phone (760) 341-2232 SAN F E L L P E
2293
Fax # (760) 341-
a <DQ, POWER BROKERS
T RU S S W O RK S 53-555 AVE HERRERA
A Company you Can Truss! LQ
75-11.0 St. Charles pl. ste-11A
Palm Desert, CA. 92211
SALES REP SB
DUE DATE :
DSGNR/CHKR SB / SB
TC Live 16.00 psf
TC Dead 14.00 psf
BC Live 0.00 psf
BC Dead 7.00 psf
Total 37.00 psf
WOµ B3253
Date 5/13/2003 14:32
DurFaC-Lbr 1.25
DurFac-Pit 1.25
O.C. Spacing 24.0
Design Spec UBC -97
µTr/µCfg : 65 / 12
hA'
2
ILI
A2
L
PACKAGE
10-7-8
Phone (760) 341-2232 SAN F E L L P E
2293
Fax # (760) 341-
a <DQ, POWER BROKERS
T RU S S W O RK S 53-555 AVE HERRERA
A Company you Can Truss! LQ
75-11.0 St. Charles pl. ste-11A
Palm Desert, CA. 92211
SALES REP SB
DUE DATE :
DSGNR/CHKR SB / SB
TC Live 16.00 psf
TC Dead 14.00 psf
BC Live 0.00 psf
BC Dead 7.00 psf
Total 37.00 psf
WOµ B3253
Date 5/13/2003 14:32
DurFaC-Lbr 1.25
DurFac-Pit 1.25
O.C. Spacing 24.0
Design Spec UBC -97
µTr/µCfg : 65 / 12
Job Dame: SAN FELIPE TOWER 4 BR
Truss ID: Al
TC 2.4 SPF 1650F -1.5E
BC 2x4 SPF 1650F -1.5E
GBL BLK 2x4 HF STUD
2.4 SPP 1650F -1.5E 13
T
7.10.0
1=
04.0
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
Loaded for 10 PSP non -concurrent BCLL.
Top chord supports 24.0 " of uniform load
at 16 psf live load and 14 psf dead load.
Additional design considerations may be
required if sheathing is attached.
[+] indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 6311intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
4.0.0 l 3-4.0 5-40 5.4-0 5.40 5-4-0 5.4-0
4-0-0 9.4-0 14-84 20-0-0 25-4.0 30.8-0 36.0.0
3 45 66 7 88 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 226 27 28 29
F4.50 -4.50
4-0
1- :0
30 31 32 33 34 35 36 37 38 39 40 414243 44 45 46 47 48 49 50 51 52534 55 56 57 58
4-0-0 5-4.0 5-4.0 5-4-O 5-4.0 5-4-0 5 4 0 _
4.0.0 9.4.0 14.8-0 20.0.0 25-4.0 30-8-0 36-04
1- :0
1 D
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
UBC Special Occupancy, Dead Load = 21.0 psf
\-j 14 2003
8-0-8
SHIP
0-0-
= Joint Locations =====
1 0- 0- 0 30 0- 0- 0
2 4- 0- 0 31 4- 0- 0
3 5- 4- 0 32 5- 4- 0
4 6- 8- 0 33 6- 8- 0
5 7- 1-12 34 8- 0- 0
6 8- 0- 0 35 9- 4- 0
7 9- 4- 0 36 10- 8- 0
8 10- 8- 0 37 12- 0- 0
9 12- 0- 0 38 13- 4- 0
10 13- 4- 0 39 14- 8- 0
11 14-8- 0 40 16- 0- 0
12 16- 0- 0 41 17- 4- 0
13 17- 4- 0 42 18- 0- 0
14 18- 8- 0 43 18- 8- 0
15 20- 0- 0 44 20- 0- 0
16 21- 4- 0 45 21-4- 0
17 22- 8- 0 46 22- 8- 0
18 24- 0- 0 47 24- 0- 0
1925- 4- 0 48 25- 4- 0
20 26- 8- 0 49 26- 8- 0
21 28- 0- 0 50 28- 0- 0
22 29- 4- 0 51 29- 4- 0
23 30- 8- 0 52 30- 8- 0
24 32- 0- 0 53 31- 6-13
25 32-10- 4 54 32- 0- 0
26 33- 4- 0 55 33- 4- 0
27 34- 8- 0 56 34- 8- 0
28 36- 0- 0 57 36- 0- 0
29 40- 0- 0 58 40- 0- 0
TYPICAL PLATE: 2-4
OVER CONTINUOUS SUPPORT
by "Mx" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
All plates are 20 gauge Truswal Connectors
unless preceded
WARNING Read all notes lois sheet give a copy oJif the Erecting Contractor.
Eng.Job:.EJ.
®
en . It c m
This design is for an individual building component not truss system. It has been based on speci ficauons provided by the component manufacturer
Chk: SB
done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr- SB
and
ng designer prior to fabrication. The building designer must ascertain that t
are to be verified by the component manufacturer and/or buildiihhe loads P
local building code and the application. The design assumes that the to chord
TC Live 16.00 psf
T R U S S W O R KS
utilized on this design meet or exceed the loading imposed by the paniculm'
braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 14.00 psf
A Company You Can TrussI
is laterally
rioted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
handle, install
0.00
environment that will cause the moisture content of the wood to exceed 19%, and/or cause connector plate corrosion. Fabricate,
BC Live psf
75-110 St. Charles pl. ste-11A
and brace this truss in accordance will, the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
INSTALLING AND BRACING METAL
BC Dead 7.00 psf
Palm Desert, CA. 92211
'ANSIrrPI 1%'WTCA I' - Wood Truss Council of America Standard Design Responsibilities,'HANDLNG
TRUSSE=S' - (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Phone (760) 341-2232
PLATE CONNECTED WOOD
Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 500. Washington, DC 20036.
TOTAL 37.00 psf
Fax # (760) 341-2293
1 Madison, Wisconsin 53719. The American
5/13/2003
Scale: 3/32" = 1'
WO: B3253
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.15
O.C.Spacing 2- 0- 0
Design Spec UBC -97
Seqn T6.3.9 - 0
Job dame: SAN FELIPE TOWER 4 BR
G X -LOC REACT SIZE REQ "I
1 0- 1-12 1591 3.50" 2.28"
2 39-10- 4 1591 3.50" 2.28"
TC
FC1kCE
AXL END CSI
1-2
-5394
0.23 0.17 0.41
1-2
-5785
0.35 0.24 0.59
2-3
-5312
0.40 0.42 0.82
3-4
-3765
0.17 0.27 0.45
4-5
-3765
0.17 0.27 0.45
5-6
-5312
0.40 0.42 0.82
6-7
-5786
0.35 0.24 0.59
6-7
-5395
0.23 0.17 0.41
BC
FORCE
AXL END CSI
8-9
5473
0.53 0.17 0.69
9-10
4599
0.68 0.14 0.82
0-11
4599
0.69 0.14 0.82
.1-12
5474
0.53 0.17 0.70
WEB FORCE CSI WEB FORCE CSI
2-9 -495 0.15 5-11 585 0.20
3-9 585 0.20 6-11 -495 0.15
3-10 -1102 0.60 SLDRL -409 0.04
4-10 2226 0.77 SLDRR -408 0.04
5-10 -1103 0.60
Truss ID: A2
7-4-11 6-3.10 , 6-3-10 6-3-10 6-3-10 7-4-11
7.4.11 13-8-6 20-0-0 26-3-10 32-7-5 40-0-0
20-0-0 l 20-0-0
1 1 2 3 4 5 6 7
4r 50 -450
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No Exp Category = C
Bldg Length = 40.00 ft, Bldg width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
UBC Special Occupancy, Dead Load = 21.0 psf
MAX DEFLECTION (span):
L/641 IN MEM 9-10 (LIVE)
L= -0.74" D= -0.98" T= -1 72"
===== Joint Locations =====
1 0- 0- 0 7 40- 0- 0
2 7- 4-11 8 0- 0- 0
3 13- 8- 6 9 10- 6- 8
4 20- 0- 0 10 20- 0- 0
5 26- 3-11 11 29- 5- 8
6 32- 7- 5 12 40- 0- 0
AR
5-5
T 3-4 3-4 (Q
3-4 , 1
7-10-0 3 3-4 5-5 5_534 8 4-8
g SHIP pK
13-12iiii5o
3 MX/5-16 3i7M= r a
U-4-0 0 4 ^ P 71. ,
Oi" Q,
0_ 8 2.00 -2.00 0-3A8
19-8-8
1
19-8-8 1 604
6 -0
A A_f1_fl
8 q !0 11 1;
10-6-8 9-5-8 9-5-8 10-6-8
10-6-8 20-0-0 29-5-8 40-0.0
, 14 2003
A 5/13/2003
Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
2x4 SPP 1650F -1.5E
Denotes the requirement for lateral bracing
TC
2x4 SPF 165OF-1.5E ®
ateach location shown. Lateral bracing
BC
2x4 SPF 210OF-1.SE 8-9, 11-12
systems which include diagonal or x -bracing
Chk: SB
2x4 HF STUD
are the responsibility of the building
WEB
2x4 SPF 1650F -1 -SE
designer. Truswal Systems BRACE -IT may be
SLIDER
ANSI/TPI - 1995
used for continuous lateral bracing on
Plating spec
THIS DESIGN
IS THE COMPOSITE RESULT OF
trussesativelyuse
spaced
MULTIPLE LOAD CASES.
scabs Ta -braces scshowntonnTzuswal
details.
PLATE VALUES
PER ICBO RESEARCH REPORT #1607.
Systems standard
Loaded for 10 PSF non -concurrent BCLL.
Unrestrained
____________________________________________
horiz. LL deflection = 0.32 "
Palm Desert, CA. 92211
7-4-11 6-3.10 , 6-3-10 6-3-10 6-3-10 7-4-11
7.4.11 13-8-6 20-0-0 26-3-10 32-7-5 40-0-0
20-0-0 l 20-0-0
1 1 2 3 4 5 6 7
4r 50 -450
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No Exp Category = C
Bldg Length = 40.00 ft, Bldg width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
UBC Special Occupancy, Dead Load = 21.0 psf
MAX DEFLECTION (span):
L/641 IN MEM 9-10 (LIVE)
L= -0.74" D= -0.98" T= -1 72"
===== Joint Locations =====
1 0- 0- 0 7 40- 0- 0
2 7- 4-11 8 0- 0- 0
3 13- 8- 6 9 10- 6- 8
4 20- 0- 0 10 20- 0- 0
5 26- 3-11 11 29- 5- 8
6 32- 7- 5 12 40- 0- 0
AR
5-5
T 3-4 3-4 (Q
3-4 , 1
7-10-0 3 3-4 5-5 5_534 8 4-8
g SHIP pK
13-12iiii5o
3 MX/5-16 3i7M= r a
U-4-0 0 4 ^ P 71. ,
Oi" Q,
0_ 8 2.00 -2.00 0-3A8
19-8-8
1
19-8-8 1 604
6 -0
A A_f1_fl
8 q !0 11 1;
10-6-8 9-5-8 9-5-8 10-6-8
10-6-8 20-0-0 29-5-8 40-0.0
, 14 2003
A 5/13/2003
Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
All plates are 20 gauge
the Erecting Contractor.
this sheet and give a cope op ci
WARNING Read all notesccomponent
Eng. Job: EJ.
®
en c
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: SB
done in accordance with the current versions o(TPI and APPA design standards. No responsibility is assumed (or dimensional accuracy. Dimensions
Dsgnr: SB
R KS
and
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
loading imposed by the local building code and the particular application. The design assumes that the top chord
TC Live 16.00 psf
T R U S S W O
th
utilized on this design meet or exceed e
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 14.00 psf
A Company You Can Truss!
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
Fabricate, handle. install
Live 0.00
that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion.
BC psf
75-110 St. Charles pl. ste-11 A
environment
brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.00 psf
Palm Desert, CA. 92211
and
'ANSVTPI 1%'WTCA I'- Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
Phone (760) 341-2232
PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'141B-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
W, 800. Washington, DC 20036,
TOTAL 37.00 psf
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, N Ste
Scale: 3132" = 1'
WO: B3253
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.15
O.C.Spacing 2- 0- 0
Design Spec UBC -97
Seqn T6.3.9 - 0
Job fame: SAN FELIPE TOWER 4 BR
G X -LOC REACT SIZE REW D
1 0- 1-12 1591 3.50" 2.28"
2 39-10- 4 1591 3.50" 2.28"
TC
FORCE
AXL BND CSI
1-2
-5821
0.47 0.44 0.92
2-3
-5295
0.41 0.46 0.87
3-4
-3768
0.12 0.33 0.44
4-5
-3768
0.12 0.33 0.44
5-6
-5295
0.41 0.46 0.87
6-7
-5821
0.47 0.44 0.92
BC
FORCE
AXL END CSI
8-9
5465
0.81 0.17 0.98
9-10
4596
0.68 0.15 0.84
0-11
4596
0.68 0.15 0.84
.1-12
5465
0.81 0.17 0.98
WEB FORCE CSI WEB FORCE CSI
2-9 -505 0.15 5-10 -1097 0.60
3-9 568 0.20 5-11 568 0.20
3-10 -1097 0.60 6-11 -505 0.15
4-10 2229 0.77
TYPICAL PLATE: 1.5-3
Truss ID: A3
TC 2x4 SPF 1650F -1.5E
BC 2x4 SPF 1650F-1.513
WEB 2x4 HF STUD
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT 01607.
Loaded for 10 PSF non -concurrent BCLL.
Unrestrained horiz. LL deflection = 0.34
----------------------------------------
T
7-10.0
T4-
0-4-0
®Denotes the requirement for lateral bracing
ateach location shown. Lateral bracing
systems which include diagonal or x -bracing
are the responsibility of the building
designer. Truswal Systems BRACE -IT may be
used for continuous lateral bracing on
trusses spaced 24" oc. Alternatively, use
scabs or T -braces as shown on Truswal
Systems standard details.
7-4-11�, 6-3-1_ 0 6-3-10 6-3-1_ 0 �, 6.3-1_ 0 7-4-1_ 1
7-4-11 13-8-6 20-0-0 26-3-10 32-7-5 40-0-0
20-0-0 20-0-0
3 a S 6 7
450 -4.50 1
5-5
1.9
This design based on chord bracing applied
per the following schedule:
maxo.c. from to
BC 120.00" 10- 8- 8 25- 2- 8
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
UBC Special Occupancy, Dead Load = 21.0 psf
SHIP
MAX DEFLECTION (span)
L/697 IN MEM 9-10 (LIVE)
L= -0.68" D= -0.90" T= -1 58"
===== Joint Locations =====
1 0- 0- 0 7 40- 0- 0
2 7- 4-11 8 0- 0- 0
3 13- 8- 6 9 10- 6- 8
4 20- 0- 0 10 20- 0- 0
5 26- 3-11 11 29- 5- 8
6 32- 7- 5 12 40- 0- 0
14-6-0
0-3q8 2.00 -2.00 0-3g8
19-8-8
1 19-8-8
dn_n_n
10-6-8 9-5-8 9-5_8 10-6-8
12
10-6-8 20-0-0 29-5.8 J 40-0-0
0A-1 J. -
All-
Connectors unless preceded by "Mx" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted
All plates are 20 gauge Truswal
WARNING Read all notes on this sheet and give u copy octo the Erecting Conti -actor.
Eng. Job: EJ.
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Dimensions
Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy.
that the loads
DSgnr: SB
are to be verified by the component manufacturer impose building designer prior to fabrication. The building designer must
assumes p
by local building code and the particular application. The design assumes that the to chord
TC Live 16.00 psf
T R U S S W O R KS
utilized on this design meet or exceed the loading imposed the
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 14.00 psf
A Company You Can Truss
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
handle, install
Live 0.00
that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate,
BC psf
75-110 St. Charles pl. ste-11 A
environment
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
INSTALLING AND BRACING METAL
BC Dead 7.00 psf
Palm Desert, CA. 92211
'ANSI/TPI 1','WTCA I'- Wood Tess Council of America Standard Design Responsibilities,'HANDLING
SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) islocatd at Drive.
Phone (760) 341-2232
0036'io
PLATE CONNECTED WOOD TRUSSES' - (1-1I13-91) and'HI13-91
Forest Paper Association (AFPA) is located N1 at 1111 19th Street, W, Ste 800,Washington.
TOTAL 37.00 psf
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American and
al
� ►� r��l2c�'
sr�TE OF CP���
200'
5/13/2003
Scale: 3/32" = 1'
WO: 83253
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.15
O.C.Spacing 2- 0- 0
Design Spec UBC -97
Seqn T6.3.9 - 0
Job Name: SAN FELIPE TOWER 4 BR Truss ID: A4
RG
X -LOC
REACT SIZE REO'D
1
0-1-12
313 3.50" 1.50"
2 10-10- 4
2074 3.50" 2.97"
3 39-10- 4
1132 3.50" 1.62"
TC
FORCE
AXL HND CSI
1-2
1080
0.13 0.61 0.74
2-3'
1596
0.22 0.61 0.83
3-4
-1516
0.02 0.37 0.39
4-5
-1516
0.02 0.36 0.38
5-6
-3074
0.07 0.36'0.43
6-7
-3658
0.21 0.47 0.68
BC
FORCE
AXL END CSI
8-9
-985
0.48 0.51 0.99
9-10
175
0.00 0.55 0.55
.0-11
2464
0.37 0.50 0.87
.1-12
3425
0.51 0.24 0.75
WEB
FORCE
CSI WEB FORCE CSI
2-9
-738 0.25
5-10 -1100 0.61
3-9
-2275 0.99
5-11 604 0.21
3-10
1366 0.47
6-11 -579 0.17
4-10
646 0.22
TC 2x4 SPF 1650F -1.5E
BC 2x4 SPF 1650F-1.513
WEB 2x4 HF STUD
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBG RESEARCH REPORT #1607.
Loaded for 10 PSF non -concurrent BCLL.
Location of interior bearings should be
clearly marked on each truss.
Permanent bracing is required (by others) to
prevent rotation/toppling. See HIB -91 and
ANSI/TPI 1-1995; 10.3.4.5 and 10.3.4.6.
T
7.10-0
T=
0-4-0
®Denotes the requirement for lateral bracing
at each location shown. Lateral bracing
systems which include diagonal or x -bracing
are the responsibility of the building
designer. Truswal Systems BRACE -IT may be
usedfor continuous lateral bracing on
trusses spaced 24" oc. Alternatively, use
scabs or T -braces as shown on Truswal
Systems standard details.
Interior support or temporary shoring must
be in place before erecting this truss.
Shim bearings (if needed) for req. support.
7-47 4-11 6-3-10 6-3-10 , 6-3-10 6-3-10 7-4-11
7-4-11 13-8-6 20-0.0 26-3-10 32-7-5 40-0-0
20-0-0 20-0-0
- 3 4 5 6 7
a -4.50
4-a
1 „p A n IV -0-0 11 11
1-1 n.n
g 9 /0
10-10-8 9-1.8
10-10-8 20-0-0
12
9-5-8 10-6-8
29-5-8 40.0-0
4 D
This design based on chord bracing applied
per the following schedule:
max O.C. from to
BC 72.00" 10- 8- 8 25- 2- 8
UPLIFT REACTION(S) :
Support 1 -44 lb
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
DEC Special Occupancy, Dead Load = 21.0 psf
----------LOAD CASE #1 DESIGN LOADS ----------------
Dir L.Plf L.Loc R.Plf R.Loc LL/TL
TC Vert 60.00 0- 0- 0 60.00 40- 0- 0 0.53
BC Vert 14.00 0- 0- 0 14.00 40- 0- 0 0.00
..Type... lbs X.Loc LL/TL
BC Vert 200.0 19- 0- 0 0.43
T
6 4.8
0-4-
MAX DEFLECTION (span)
L/999 IN MSM 11-12 (LIVE)
L= -0.26" D= -0.34" T= -0160-
=====
060"
===== Joint Locations =====
1 0- 0- 0 7 40- 0- 0
2 7- 4-11 8 0- 0- 0
3 13- 8- 6 9 10-10- 8
4 20- 0- 0 10 20- 0- 0
5 26- 3-11 11 29- 5- 8
6 32- 7- 5 12 40- 0- 0
0
1 2403
TYPICAL PLATE: 1.5-3
OVER 3 SUPPORTS
by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
All plates are 20 gauge Truswal Connectors
unless preceded
Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job: EJ.
®WARNING
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
Dsgnr' SB
U S S W O R KS
be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
a e be
loading by the local building code and the particular application. The design assumes that the top chord
TC Live 16.00 psf
T R
on this design meet or exceed the impose
utilizd
is laterally braced by the roof or floor sheathing mid the bottom chord is laterally braced by a rigid sheathing material directly attached, unless othenvlsc
TC Dead 14.00 psf
A Company You Can TrussI
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
75-110 St. Charles pl. ste-11 A
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.00 psf
Palm Desert, CA. 92211
'ANSI/TPI I-,'wTCA I'- Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
Phone (760) 341-2232
PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'I41B-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
TOTAL 37.00 psf
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I 1 I 119th Street, NW, Ste 500. Washington, DC 20036.
5/13/2003
Scale: 3/32" = 1'
WO: 83253
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.00
O.C.Spacing 2- 0- 0
Design Spec UBC -97
Seqn T6.3.9 - 0
Job Nall
RG X -LOC
1 0-1-12
2 10-10- 4
3 39-10- 4
TC FORCE
1-2 1080
2-3 1596
3-4 -1516
4-5 -1516
5-6 -3074
6-7 -3658
: SAN FELIPE TOWER 4 BR Truss ID: A5
REACT SIZE REQ'D
313 3.50" 1.50"
2074 3.50" 2.97"
1132 3.50" 1.62"
AXL BND CSI
0.13 0.61 0.74
0.22 0.61 0.83
0.02 0.37 0.39
0.02 0.36 0.38
0.07 0.36 0.43
0.21 0.47 0.68
BC FORCE AXL END CSI
8-9 -985 0.48 0.51 0.99
9-10 175 0.00 0.55 0.55
0-11 2464 0.37 0.50 0.87
1-12 3425 0.51 0.24 0.75
WEB FORCE CSI WEB FORCE CSI
2-9 -738 0.25 5-10 -1100 0.61
3-9 -2275 0.99 5-11 604 0.21
3-10 1366 0.47 6-11 -579 0.17
4-10 646 0.22
TC 2x4 SPF 1650F-1.513
BC 2x4 SPF 1650F-1.513
WEB 2x4 HF STUD
GBL BLK 2x4 HP STUD
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
Loaded for 10 PSF non -concurrent BCLL.
Interior support or temporary shoring must
be in place before erecting this truss.
Gable verticals are 2x 4 web material spaced
at 16.0 " o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 16 psf live load and 14 psf dead load.
Additional design considerations may be
required if sheathing is attached.
[+) indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 63"intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
T
7-10-0
T=
0-4-0
®Denotes the requirement for lateral bracing
at each location shown. Lateral bracing
systems which include diagonal or x -bracing
are the responsibility of the building
designer. Truswal Systems BRACE -IT may be
used for continuous lateral bracing on
trusses spaced 24" oc. Alternatively, use
scabs or T -braces as shown on Truswal
Systems standard details.
Location of interior bearings should be
clearly marked on each truss.
Permanent bracing is required (by others) to
prevent rotation/toppling. See HIB -91 and
ANSI/TPI 1-1995; 10.3.4.5 and 10.3.4.6.
Shim bearings (if needed) for req. support.
7-4-11 6-3-10 6.3-10 6-3-10 6-3-10 7-4-11
7-4-11 13-8-6 20-0-0 26-3-10 32-7-5 40-0-0
20-0-0 20-0-0
3 4 5 6 7
41 550
4-4
-4.50 1
19-8-8
1 601
en -n -n
9 10 /J
10-10-8 9-1-8 9-5-8 10-6.8
10.10.8 20-0-0 J 29-5-8 J 40-0-0
This design based on chord bracing applied
per the following schedule:
max O.C. from to
BC 72.00" 10- 8- 8 39- 8- 8
UPLIFT REACTION(S) :
Support 1 -44 lb
This truss is designed using the
UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg width = 20.00 ft
Mean roof height = 18.92 ft, mph = 80
UBC Special occupancy, Dead Load = 21.0 psf
--LOAD CASE #1 DESIGN LOADS ----------------
Dir L.Plf L.Loc R.Plf R.Loc LL/TL
TC Vert 60.00 0- 0- 0 60.00 40- 0- 0 0.53
BC Vert 14.00 0- 0- 0 14.00 40- 0- 0 0.00
..Type... lbs X.Loc LL/TL
BC Vert 200.0 19- 0- 0 0.43
MAX DEFLECTION (span)
L/999 IN MEM 11-12 (LIVB)
L= -0.26" D= -0.34" T= -0 6011
Joint Locations =====
1 0- 0- 0 7 40- 0- 0
2 7- 4-11 8 0- 0- 0
3 13- 8- 6 9 10-10- 8
4 20- 0- 0 10 20- 0- 0
5 26- 3-11 11 29- 5- 8
6 32- 7- 5 12 40- 0- 0
T p ARCHjTFc
5 Sp. GA
8 4-8
SHIP
=0 4-•c
VIP
SIA
TYPICAL PLATE: 1.5-3
OVER 3 SUPPORTS
All plates are 20 gauge Truswal Connectors unless preceded by "Mx" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted.
® Eng. Job: EJ.
WARNING Read all notes on this sheet and give a copy of it to the EI-ecting Conn-actoi-.
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions DSgnr: SB
T R U S S W O R KS are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 16.00 psf
I is laterally braced by the roof or Moor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Dead 14.00 psf
A Company You Can Truss
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install BC Live 0.00 psf
75-110 St. Charles pl. ste-11 A and bmce this Huss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software', BC Dead 7.00 psf
Palm Desert, CA. 92211 'ANSI/TPI 1','WTCA I'- Wood Truss Council of America Standard Design Responsibilities.'HAN DLI NG INSTALLING AND BRACI'NG METAL
Phone (760) 341-2232 PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'IIIB-91 SUMMARI' SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofi'io Drive,
Fax # (760) 341-2293 Madison- Wisconsin 53719. The American Forest and Paper Association (APPA) is located at 1111 19th Street. NW, Ste 800, Washington, DC 20036. TOTAL 37.00 PSI
5/13/2003
Scale: 3/32" = 1
WO: 83253
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.00
O.C.Spacing 2- 0- 0
Design Spec UBC -97
Seqn T6.3.9
Job Name: SAN FELIPE TOWER 4 BR Truss
ID: B1 Qty: 1
Drwg:
RG
A�LOC
REACT SIZE REO'D
TC 2x4 SPF 165OF-1.5E
Plating spec : ANSI/TPI - 1995
UPLIFT REACTION(S)
0-
966 3.50"
1.50"
BC 2x4 SPF 165OF-1.5E
THIS DESIGN IS THE COMPOSITE RESULT OF
Support 1 -24 lb
1
2
1-12
21- 5- 4
849 3.50"
1.50"
WEB 2x4 HF STUD
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
Support 2 -2 lb
This truss is designed using the
GBL BLK 2x4 HF STUD
Gable verticals are 2x 4 web material spaced
Loaded for 10 PSP non concurrent BCLL.
UBC -97 Code.
TC
FORCE
AxL BND
CSI
at 16.0 " o.c. unless noted Otherwise.
Bldg Enclmd = Yes
1-2
-'47.67
0.02 0.31
0.34
Top chord supports 25.5 " of uniform load
Truss Location = End Zone
2-3
-1271
0.01 0.31
0.33
at 16 psf live load and 14 psf dead load.
Hurricane/Ocean Line = No Exp Category = C
3-4
-1267
0.02 0.24
0.26
Additional design considerations may be
Bldg Length = 40.00 ft, Bldg Width 20.00 ft
4-5
-1692
0.02 0.36
0.39
_=
Mean roof height = 17.23 ft, mph - 80
required if sheathing is attached.
UBC Special Occupancy, Dead Load = 21.0 psf
BC
FORCE
AXL 8ND
CSI
C+] indicates the requirement for lateral
6-7
1614
0.16 0.43
0.59
bracing (designed by others) perpendicular
7-8
1526
0.15 0.43
0.58
to the plane of the member at 63 -intervals.
Bracing is a result of wind load applied
WEB
FORCE
CSI WEB
FORCE CSI
to member.(Combination axial plus bending).
2-7
-520 0.35
4-7
-426 0.28
This truss requires adequate sheathing, as
3-7
514 0.18
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
5-10_5
5-10-5
2
450
MAX DEFLECTION (span) :
L/999 IN MEM 6-7 (LIVE)
L= -0.13" D= -0.17" T= -0
===== Joint Locations =====
1 0- 0- 0 5 21- 7- 0
2 5-10- 5 6 0- 0- 0
5-1-11 5-1-11 5-55-5 5 3 11- 0- 0 7 11- 0- 0
11-0-0 16-1-11 21-7-0 4 16- 1-11 8 21- 7- 0
4-4
0
4.50
,1-6-0 ,, v
' 21-7-0
t-0-5-0�A
6 7 a STUB 1 n
11-011.0 0 10-7.0
11-0-0 21-7-0
TYPICAL PLATE: 1.5-3
e 1�
v �Q �r2�
1 � 2003
5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "W" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 7/32" = 1'
®
T R U S S W O R KS
A Company You Can Truss!
Charles pl. ste-11 A
75-110 St. Cha
Palm Desert, rle pl. s
Phone (760) 341-2232
Fax # (760) 341-2293
YY ALR1 vll v G Read all notes on this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
is laterally braced by the roof or Boor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
'ANSI/fPI I-, -wTCA I' - Wood Truss Council of America Standard Design Responsibilities. 1IAN DLI INSTALLING AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1 111 19th Street. NW, Ste 800, Washington. DC 20036.
Eng. Job: EJ.
Chk: SB
Dsgnr: SB
WO: 83253
TC Live 16.00 psf
TC Dead 14.00 psf
BC Live 0.00 psf
BC Dead 7.00 psf
TOTAL 37.00 psf
DurFacs L=1.25 P=1.25
Rep Mbr Bnd 1.00
O.C.Spaeing 2- 1- 8
Design Spec UBC -97
Seqn T6.3.9 - 0
Job Name: SAN FELIPE TOWER 4 BR Truss ID: B2 Qty: 2 Drwg:
RG i -LOC REACT SIZE REOD TC 2x4 SPF 1650F -1.5E Plating spec : ANSI/TPI - 1995 UPLIFT REACTION(S)
1 0- 1-12 909 3.50" 1.50" BC 2x4 SPF 1650F -1.5E THIS DESIGN IS THE COMPOSITE RESULT OF Support 1 -27 lb
2 21- 5- 4 799 3.50" 1.50" WEB 2x4 HF STUD MULTIPLE LOAD CASES. Support 2 -5 lb
Loaded for 10 PSF non -concurrent BOLL.' PLATE VALUES PER ICBO RESEARCH REPORT #1607. This truss is designed using the
TC FORCE. AXL END CSI UBC -97 Code.
1-2 -1663 0.02 0.26 0.28 Bldg Enclosed
2-3 -1196 0.01 0.26 0.27 Truss Location = End Zone
3-4 -1193 0.02 0.19 0.21 Hurricane/Ocean Line = No , Exp Category = C
4-5 -1592 0.02 0.30 0.32 Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mearoof height = 17.23 ft, mph - 80
Mean
BC FORCE AxL END CSI USC Special Occupancy, Dead Load = 21.0 psf
6-7 1519 0.15 0.35 0.50
7-8 1437 0.14 0.35 0.49
WEB FORCE CSI WEB FORCE CSI
2-7 -489 0.33 4-7 -401 0.27
3-7 484 0.17
8„
.1-6=0 ,
6
5-10.5 5-1-11 5-111 5.5-5
5-10-5 11-0.0 16-1-11 21-7-0
3 a s
4 -4.50 l
7
11-0-0
11-0-0
===== Joint Locations ===--
1 0- 0- 0 5 21- 7- 0
2 5-10- 5 6 0- 0- 0
3 11- 0- 0 7 11- 0- 0
4 16- 1-11 8 21- 7- 0
U \,T 1 k 2003
0.51 0
8 STUB
10-7-0
217 5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "Mx" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 7/32" = 1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job: EJ.
WO: 83253
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
DSgnr: SB
are be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
TC Live 16.00 psf
DurFacs L=1.25 P=1.25
T R U S SW O R KS
utiliztoed on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
A Company You Can Truss!
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
TC Dead 14.00
Rep Mbr end 1.15
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
psf
A
envnomnent that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
O.C.Spaoing 2- 0.0
Charles pl. ste-11
75-110 St. Charle s
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
BC Dead 7.00
Design Spec UBC -97
9pl.
Desert,
Palm Desert
'ANSI/TPI I','WTCA I'- Wood Truss Council of America Standard Design Responsibilities, 'HA N DLING [INSTALLING AND BRACING METAL
psf
Phone (760) 341-2232
PLATE CONNE=CTED WOOD TRUSSES' - (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onoftio Drive,
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 37.00 psf
Seqn T6.3.9 - 0
Il
Job Name: SAN FELIPE TOWER 4 BR Truss ID: 133 Qty: 1 Drwg:
sRGX--LOC REACT SIZE REQ'D
1 0- 1-12 909 3.50" 1.50"
2 21- 5- 4 799 3.50" 1.50"
TC FORCE AXL END CSI
1-2 -1663 0.02 0.26 0.28
2-3 -1196 0.01 0.26 0.27
3-4 -1193 0.02 0.19 0.21
4-5 -1592 0.02 0.30 0.32
BC FORCE AXL END CSI
6-7 1519 0.15 0.35 0.50
7-8 1437 0.14 0.35 0.49
WEB FORCE CSI WEB FORCE CSI
2-7 -489 0.33 4-7 -401 0.27
3-7 484 0.17
TYPICAL PLATE: 1.5-3
TC 2x4 SPF 1650F -1.5E
BC 2x4 SPF 1650F -1.5E
WEB 2x4 HF STUD
GBL BLK 2x4 HF STUD
Gable verticals are 2x 4 web material spaced
at 16.0 o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 16 psf live load and 14 psf dead load.
Additional design considerations may be
required if sheathing is attached.
(+) indicates the requirement for lateral
bracing (designed by others) perpendicular
to the plane of the member at 6311intervals.
Bracing is a result of wind load applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
Plating spec : ANSI/TPI - 1995 UPLIFT REACTIONS) :
THIS DESIGN IS THE COMPOSITE RESULT OF Support 1 -27 lb
MULTIPLE LOAD CASES. Support 2 -5 lb
PLATE VALUES PER ICBO RESEARCH REPORT #1607. This truss is designed using the
Loaded for 10 PSF non -concurrent BCLL. UBC -97 Code.
Bldg Enclosed = Yes
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mean roof height = 17.23 ft, mph - 80
UBC Special Occupancy, Dead Load = 21.0 psf
55-1 5-1-11 5-111 5-55
5-10-5 11-0-0 16-1-11 21-7-0
11-0-0 I 10-7-0
/ 2 3 a s
450 -450
4-4
5-0-0
1 SHIP
MAX DEFLECTION (span) :
L/999 IN MEM 6-7 (LIVE)
L= -0.12" D= -0.16" T= -0
===== Joint Locations =----
1 0- 0- 0 5 21- 7- 0
2 5-10- 5 6 0- 0- 0
3 11- 0- 0 7 11- 0- 0
4 16- 1-11 8 21- 7- 0
z . roo ..
0
1
6
7
11-011-0
11-0-0
0-5I 0 -
8 STUB
10-710-7 0
21-7-0
11-iL./kIV
O N
5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 7/32" = 1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job: EJ.
WO: 83253
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: SB
and dote in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
Dsgnr: SB
TC Live 16.00 psf
DurFaes L=1.25 P=1.25
T R U S S W O R KS
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
A Company You Can Truss!
is laterally braced by the roof or Floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
TC Dead 14.00 psf
Rep Mbr Bnd 1.15
75-110 at. Charles pl. ste-11 A
Palm Desert, CA. 92211
Phone (760) 341-2232
Fax # (760) 341-2293
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
'ANSI/TPI 1','WTCA 1' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
PLATE CONNECTED WOOD TRUSSES' . (MIB -91) mtd'HIB-91 SUMMARY SHEET" by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1 111 19th Street, NW, Ste 800, Washington, DC 20036.
BC Live 0.00 psf
BC Dead 7.00 psf
TOTAL 37.00 psf
O.C.Spaeing 2- 0- 0
Design Spec UBC -97
Segn T6.3.9 - 0
Job Name: SAN FELIPE TOWER 4 BR Truss ID: B4 Qty: 4 Drwg:
RG .)i -LOC REACT SIZE REO'D TC 2x4 SPF 165OF-1.SE Plating Spec : ANSI/TPI - 1995 UPLIFT REACTION(S)
1 0- 1-12 925 3.50^ 1.50" BC 2x4 SPF 1650F -1.5E THIS DESIGN IS THE COMPOSITE RESULT OF Support 1 -26 Lb
2 21-10- 4 925 3.50" 1.50" WEB 2x4 HF STUD MULTIPLE LOAD CASES. Support 2 -26 lb
Loaded for 10 PSF non -concurrent BCLL. PLATE VALUES PER ICBO RESEARCH REPORT #1607. This truss is designed using the
TC FORCE AXL BND CSI UBC -97 Code.
1-2 -17100.02 0.25 0.27 Bldg Enclosed = Yes
2-3 -1246 0.01 0.25 0.27 Truss Location = End Zone
3-4 -1246 0.01 0.25 0.27 Hurricane/Ocean Line = No , Exp Category = C
4-5 -1710 0.02 0.25 0.27 Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mean roof height = 17.23 ft, mph - 80
BC FORCE AXL END CSI UBC Special Occupancy, Dead Load = 21.0 psf
6-7 1563 0.16 0.38 0.54
7-8 1563 0.16 0.38 0.54
WEB FORCE CSI WEB FORCE CSI
2-7 -487 0.33 4-7 -487 0.33
3-7 531 0.18
5"
55-1 5-1-11 5-111 5-10-5
5-10-5 11-0.0 16-1.11 22-0-0
11-0-0 I 11-0-0
r 2 3 a s
450 -450
4-4
===== Joint Locations =----
1 0- 0- 0 5 22- 0- 0
2 5-10- 5 6 0- 0- 0
3 11- 0- 0 7 11- 0- 0
4 16- 1-11 8 22- 0- 0
P4C-) v" V111y14,jC
MAO
MOO
1F6_i
0 1 -0
22-0-0 QA)
' 6 7
11-011-0 11-011-0
11-0-0 22-0-0
5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 3/16" = 1'
® WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Eng. Job: EJ. WO: 83253
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgnr: SB
T R U S S W O R KS are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
utilized on this design meet or exceed the loading imposed by the local building code and the panicular application. The design assumes that the top chord TC Live 16.00 psf DurFacs L=1.25 P=1.25
A Com an You Can Truss! is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
p y noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 14.00 psf Rep Mbr Bnd 1.15
environment that will cause the moisture content of the wood to exceed 19%and/or cause connector plate corrosion. Fabricate, handle, install BC Live 0.00 psf O.C.S aeln 2- 0- 0
75-110 St. Charles pl. ste-11A P P s
Palm Desert, CA. 92211 and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software',
'ANSI/TPl I','WTCA I'- Wood Truss Council of America Standard Design Responsibilities,'IIANDLING INSTALLING AND BRACING METAL BC Dead 7.00 psf Design Spec UBC -97
Phone (760) 341-2232 PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Fax # (760) 341-2293 Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street. NW, Ste 500, Washington, DC 20036. TOTAL 37.00 psf Seqn T6.3.9 - 0
Job Name: SAN FELIPE TOWER 4 BR
Truss
ID: B5 Qty: 1
Drwg:
RG
,X -LOC
REACT SIZE REOD
TC 2x4 SPF 1650F-1.59
Plating spec : ANSI/TPI - 1995
This design based on chord bracing applied
1
0- 1-12
925 3.50"
1.50^
BC 2x4 SPF 1650F 1.5E
THIS DESIGN IS THE COMPOSITE RESULT OF
per the following schedule:
2
21-10- 4
925 3.50
.1.50^
WEB 2x4 HF STUD
MULTIPLE LOAD CASES.
max o.c. from to
TC Dead 14.00 psf
*
75-110 St. Charles pl. ste-11 A
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
'Joint
2x4 SPF 165OF-1.5E
2-7
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
TC 24.00" 7- 2- 1 14- 0- 0
TC
FORCE
AXL BND
CSI
Drainage must be provided to avoid
ponding.
Loaded for 10 PSF non -concurrent BCLL.
UPLIFT REACTION(S)
1-2
-1662
0.04 0.33
0.37
This truss is designed using the
Seqn T6.3.9 - 0
2x4 continuous lateral bracing 024.0 " o.c.
Support 1 -25 lb
2-3
-^•_515
0.04 0.43
0.47
UBC -97 Code.
attached w/ 2-10d box or common wire nails.
Support 2 -25 lb
3-4
-1661
0.04 0.33
0.37
Bldg Enclosed = Yes
Truss Location = End Zone
BC
FORCE
AXL BND
CSI
Hurricane/Ocean Line = No , Exp Category = C
5-6
1499
0.22 0.16
0.38
Bldg Length = 40.00 ft, Bldg Width
= 20.00
ft
6-7
1509
0.23 0.12
0.34
Mean roof height = 17.04 ft, mph
= 80
7-8
1498
0.22 0.16
0.38
UBC Special Occupancy, Dead Load =
21.0 psf
WEB
FORCE CSI WEB
FORCE CSI
2-6
153 0.05
3-7
144 0.05
2-7
91 0.06
7"
T
4-0-14
TMD -4-0
7-7-5 6-96-95
7-7.5 14-4-11
9-11-11 I
/ ? 3
4 6-0-0
7-77-7 5
22-0-0
1
4
-4
T
4-7.6
===== Joint Locations =====
1 0- 0- 0 5 0- 0- 0
2 7- 7- 5 6 7- 5- 9
3 14- 4-11 7 14- 4-11
4 22- 0- 0 8 22- 0- 0
':00.
1 -0 I 1O --I
7-5-9 6-11-1 7-7-5 y`
7-5-9 14-4-11 22-0-0
5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "MV for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 3/16" = 1'
WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor.
Eng. Job: EJ.
WO: B3253
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk' SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
T R U S S W O R KS
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
Dsgnr: SB
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TC Live 16.00 psf
DurFaes L=1.25 P=1.25
A Company You Can Truss!
is laterally braced by the roof or Floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral suppon of components members only to reduce buckling length. This component shall not be placed in any
TC Dead 14.00 psf
Rep Mbr Bnd 1.15
75-110 St. Charles pl. ste-11 A
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
'Joint
BC Live 0.00 psf
O.C.$paCiOg 2- 0- 0
Palm Desert, CA. 92211
and brace this truss in accordance with the following standards: and Cutting Detail Reports available as output from iluswal software'.
'ANSI/TPI
1','WTCA I' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
BC Dead 7.00 psf
Design Spec UBC -97
Phone (760) 341-2232
PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'HIB-91 SUMMARY SHEET" by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 37.00 psf
Seqn T6.3.9 - 0
lJob Name: SAN FELIPE TOWER 4 BR Truss ID: 136 Qtv: 2 Drwa:
RG ,X -LOC REACT SIZE REQ'D
1 0- 1-12 1732 3.50" 1.50"
2 21-10- 4 1732 3.50" 1.50"
TC FORCE AXL END CSI
1-2 -3771 0.03 0.42 0.45
2-3 43539 0.07 0.78 0.85
3-4 -3788 0.03 0.44 0.48
BC FORCE AXL BND CSI
5-6 3487 0.26 0.10 0.36
6-7 3508 0.26 0.12 0.38
7-8 3504 0.26 0.12 0.38
WEB FORCE CSI WEB FORCE CSI
2-6 246 0.04 3-7 248 0.04
2-7 90 0.01
TC 2x4 SPF 1650F:l.5E
2x4 SPF 210OF1.8E 2-3
BC 2x4 SPF 1650F-1.513
WEB 2x4 HF STUD
2x4 SPF 1650F -1.5E 2-7
Lumber shear allowables are per NDS -97.
Drainage must be provided to avoid ponding.
Permanent bracing is required (by others) to
prevent rotation/toppling. See HIB -91 and
ANSI/TPI 1-1995; 10.3.4.5 and 10.3.4.6.
2-PLYI Nail w/10d BOX, staggered (NDS -97
Sect. 12) in: TC- 2/ft BC- 2/ft WEBS- 2/ft
Plating spec : ANSI/TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
Loaded for 10 PSF non -concurrent BOLL.
Nail pattern shown is for uniform loads
only. Concentrated loads > 350# must be
distributed (by others) equally to each
ply, unless nail clusters are shown ( ).
2x4 continuous lateral bracing @24.0 " o.c.
attached w/ 2-10d box or common wire nails.
77-7-5 6-9-5 7-7-5
7-7-5 14-4-11 22-0-0
1 7-11-11 I 7-11-11
2-PLYS ' 3
REQUIRED F4-.50 330# 6-0-0 -4.50
This design based on chord bracing applied
per the following schedule:
Eng. Job: EJ.
max o.c. from to
®
TC 24.00" 7-11-11 14- 0- 0
Chk' SB
UPLIFT REACTION(S) :
Support 1 -22 lb
Support 2 -22 lb
T R U S S W O R KS
This truss is designed using the
Dsgnr: SB
UBC -97 Code.
Bldg Enclosed = Yes
TC Live 16.00 psf
Truss Location = End Zone
A Company You Can Truss!
Hurricane/Ocean Line = No , Exp Category = C
Bldg Length = 40.00 ft, Bldg Width = 20.00 ft
Mean roof height = 16.66 ft, mph - 80
TC Dead 14.00 psf
UBC Special Occupancy, Dead Load = 21.0 psf
75-110 St. Charles pl. ste-11 A
----------LOAD CASE #1 DESIGN LOADS ----------------
SC Live 0.00 psf
Dir L.Plf L.Loc R.Plf R.Loc
LL/TL
TC Vert 60.00 0- 0- 0 60.00 8- 0- 0
0.53
TC Vert 145.63 8- 0- 0 145.63 14- 0- 0
0.53
TC Vert 60.00 14- 0- 0 60.00 22- 0- 0
0.53
BC Vert 33.98 0- 0- 0 33.98 22- 0- 0
0.00
..Type... lbs X.Loc LL/TL
TC Vert 176.0 8- 0- 0 1.00
Fax # (760) 341-2293
TC Vert 154.0 8- 0- 0 0.00
TOTAL 37.00 psf
TC Vert 176.0 14- 0- 0 1.00
TC Vert 154.0 14- 0- 0 0.00
MAX DEFLECTION (span) :
L/999 IN MEM 6-7 (LIVE)
L= -0.09" D= -0.11" T= -0
===== Joint Locations =----
1 0- 0- 0 5 0- 0- 0
2 7- 7- 5 6 7- 5- 9
3 14- 4-11 7 14- 4-11
4 22- 0- 0 8 22- 0- 0
3
5-
T APIC W,7
3-3-14 3 0. GAA C/
3-4 3 4 SHIP "Q
:110-4-0 1.5-3 5-5 -MD-4-01
16-o I
M
6 7 8
7-5-9 6-1 7-7-5 ^
7-5-9 14-4-11 22-0-0 GOO
ON 5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "MX" for HS 20 gauge or -H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 3/16" = 1'
WARNING Read all notes on this sheet and give a copy of it to the Erecling Contractor.
Eng. Job: EJ.
WO: 83253
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk' SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
T R U S S W O R KS
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
Dsgnr: SB
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
TC Live 16.00 psf
DurFaes L=1.25 P=1.25
A Company You Can Truss!
is laterally braced by the roof or Boor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
TC Dead 14.00 psf
Rep Mbr Bnd 1.00
75-110 St. Charles pl. ste-11 A
environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install
'Joint
SC Live 0.00 psf
O.C.Spaeing 2- 0- 0
Palm Desert, CA. 92211
and brace this truss in accordance with the following standards: and Cutting Detail Reports available as output from Truswal software',
'ANSI/TPI
I','WTCA I' - Wood Truss Council of America Standard Design Responsibilities,'HANDLING INSTALLING AND BRACING METAL
BC Dead 7.00 psf
Design Spec UBC -97
Phone (760) 341-2232
PLATE CONNECTED WOOD TRUSSES'- (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800. Washington, DC 20036.
TOTAL 37.00 psf
Seqn T6.3.9 - 0
Job Name: SAN FELIPE TOWER 4 BR Truss
ID: C1 Qty: 2
Drw :
Eng. Job: EJ.
WO: 83253
®
RG
x -LOC
REACT SIZE REQ'D
TC 2x4 SPF 165OF-1.513
Plating spec : ANSI/TPI - 1995
UPLIFT REACTION(S)
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
1
0- 1-12
679 3.50"
1.50"
BC 2x4 SPF 165OF-1.SE
THIS DESIGN IS THE COMPOSITE RESULT OF
Support 1 -38 lb
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
2
10- 5-12
679 3.50^
1.50"
WEB 2x4 HF STUD
MULTIPLE LOAD CASES.
Support 2 -38 lb
O.C.S actin 2- 0- 0
P s
Palm Desert, CA. 92211
and brace this truss in accordance with the following standards: 'Joint and Cueing Detail Reports available as output from Truswal software',
'ANSI/TPI 'HAN
1','WTCA I'- Wood Truss Council of America Standard Design Responsibilities, DLI NG INSTALLING AND BRACING METAL
Permanent bracing is required (by others) to
PLATE VALUES PER ICBO RESEARCH REPORT #1607.
This truss is designed using
the
TC
FORCE
AXL BND
CSI
prevent rotation/toppling. See HIB -91 and
UBC -97 Code.
1-2
-1048
0.01 0.20
0.21
ANSI/TPI 1-1995; 10.3.4.5 and 10.3.4.6.
Bldg Enclosed = Yes
2-3
-'1048
0.01 0.20
0.21
Truss Location = End Zone
Hurricane/Ocean Line = No , Exp Category
= C
BC
FORCE
AXL END
CSI
Bldg Length = 40.00 ft, Bldg
Width
= 20.00
ft
4-5
940
0.14 0.14
0.28
Mean roof height = 16.16 ft,
mph -
80
5-6
940
0.14 0.14
0.28
UBC Special Occupancy, Dead Load =
21.0 psf
----------LOAD CASE #1 DESIGN
LOADS
----------------
WEB
FORCE CSI WEB
FORCE CSI
Dir L.Plf L.Loc
R.Plf
R.Loc
LL/TL
2-5
169 0.06
TC Vert 60.00 0- 0- 0
60.00
10- 7- 8
0.53
Be vert 25.59 0- 0- 0
25.59
10- 7- 8
0.00
..Type... lbs X.Loc
LL/TL
TC Vert 121.3 5- 3-12
1.00
TC Vert 106.2 5- 3-12
0.00
T
2-3-14
IO -4-0
5-35-312
5-3-12
450 228# '
4-4
450
5-3-12
10-7-8
1-6-0 -1 1-6-010.7-8
a
5-3-12_i
5-3-12
5
6
5-35-312
10-7-8
t Q
2-10-6
SHIP
JO -4.0
(41
MAX DEFLECTION (span) :
L/999 IN MEM 5-6 (LIVE)
L= -0.02" D= -0.03" T= -0
===== Joint Locations =====
1 0- 0- 0 4 0- 0- 0
2 5- 3-12 5 5- 3-12
3 10- 7- 8 6 10- 7- 8
14 I -M,
5/13/2003
All plates are 20 gauge Truswal Connectors unless preceded by "Mx" for HS 20 gauge or "H" for 16 gauge, positioned per Joint Detail Reports available from Truswal software, unless noted. Scale: 11/32" = 1'
WARNING Read all notes on this sheet and give a CoPy of it to the Erecting Contractor.
Eng. Job: EJ.
WO: 83253
®
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
Chk: SB
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
Dsgnf: SB
TC Live 16.00 psf
DurFaes L=1.25 P=1.25
T R U S S W O R KS
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
A Company You Can Truss!
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
TC Dead 14.00 psf
Rep Mbr Bnd 1.00
75 110 St. Charles pl. ste-11A
environment that will cause the moisture content of the wood to exceed 19'7 and/or cause connector plate corrosion. Fabricate, handle, install
BC Live 0.00 psf
P
O.C.S actin 2- 0- 0
P s
Palm Desert, CA. 92211
and brace this truss in accordance with the following standards: 'Joint and Cueing Detail Reports available as output from Truswal software',
'ANSI/TPI 'HAN
1','WTCA I'- Wood Truss Council of America Standard Design Responsibilities, DLI NG INSTALLING AND BRACING METAL
BC Dead 7.00 psf
Design Spec UBC -97
Phone (760) 341-2232
PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'HIB-91 SUMMARY SHEET' by TPI. The Truss Plate Institute (TPI) is located at D'Onofrio Drive,
Fax # (760) 341-2293
Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 11 1 1 19th Street, NW, Ste 800, Washington, DC 20036.
TOTAL 37.00 psf
Seqn T6.3.9 - 0
I. i4
1 .
`e '!II; 14 jllt+.il[.i{,ijil'I, .tl
I
I4 I
I. 2x<' POST ATTACU--D TO EACH TRUSS PANEL POINT AND OVERJ IEAD
PU :LIN
IIr 2. 2x4 H i f IF OR H2 DF PURLINS 4' • 0 " O.0 4
I
J. 2x4 111 I IF OR H2 DF CONTINUOUS STIFFENER ATTACHED TO POST.
4. HIP TRUSS HI SETBACK FROM END WALL AS NOTED ON TRUSS DESIGN.
I f I '.I'I •, 5. EXTENDED END JACK TOP CHORD TYPICAL
i I i'ly.i LI I.I •r ;' .lu t {. A 6. COMMON TRUSS. S
}IIP CORNER RAFTER.
o 0
j' I! ,y ,I p ''•• II \ _ 8. Ix,;CONTINUOUS LATERAL BILKING.
9. ,F -ENDED BOTTOM CHORD.
KDSECTION A
I' I I JI LATERAL STABILITY OF ROOF
it till i %'I`l I it SYSTEM IS PER BUILDINO DESIGNLR.
Il q y
1 f :. is ^ ' ,• . L+.' / " ,.
li SETBACK AS NOTED
ii ON TRUSS DESIGN. HIP TRUSSES 24" 0 C. (TYPI&L!`v
, ,I,I ` ti ,IIIc Y;. A w'ti,, ti/(i(iY / ,/r% • - '>:<,
41+ sI 1 : rnil 1 nHin, /,i - % ` .I•r
IDATE
WARNING no all notes on this sheet and give co
l a ; rna d...W c Iw en a d..d<ut b 9 copy of It to The Erecting Contractor.
ul&Wa,
r!' m0 congoners. n naa wen based on speY,ecauons p.ovdetl W me component manulacawer and dome e,
acco'dance worn 'he a re"` voswne d TPI and APPA des
Vn staWwaj. No res PentreJey u "swnW to, dm.nponAl aeCwKY OmMywy Ne
'9 n1 1 Y pones manuhcigoa snows burWalp durynw yod !d cdrueon flq uurld.r<p d.a<yrwr aMY utHWn INI uN bada
I' .' ' (DETAIL 1 /2 1 /9 g ° t wate<I wl dos owrpn rnllet a ueeed Ibe Watlnp rnpusW by lee 4.ul lAek►ny code 11 re uswnwl nW ew lop eldrtl a ILMaY/ Orated tr»
root W "'w meal b1'
.la'.i ''q r iwp Glut the bottom chord a l"b"y .ac.d bra NUN la'"b p mateeW doe<111 nualw. wdeae awrwe mood er
.l 11 `I stwwn n Im ateral suopot of components members otdy to,euww w,"Nn yVw
y. j pm. rna compomeM " not nd pt e, n M er<reo Mee
S m
i i , I' '• I ryry, 1, T ®®`' S r<W Vuae the mwstwe coNeN of Iw we00 e.cMd I91 and/or CNree c01uMKlw pas cwro/<On. FdWu;dle. IWpe, nfVM y10 dey dW Yy/e N
1INSWAE-YSIEMS COWCAMION accwtldncewAn Ine tdl"np alanoade 'TRUSCOM MANUAL' by Ttu■wA. *OUAUTY CONTROL SIAWARO FOR METAL PULE CONNECfFO
w000 InUSSES'.
II I'i;ir (OSGAEI. wAmoUNo W9f umc Allo eRACINO METAL PLAIE COrINECtEo W000 ItiUSSe3, • (NU-pO ",ne.et
i jyj i 110, JUMMARY SNt:Ef' by IPI, the Truss Plate MCMwe (TP1) is located At 547 O'Onofw Ori.a, MedrrOn, Wuwnan $3119. fM Iunonu Pwep and
t I td Paper Ateot,stron (APPA) Is lOCaled al 1250 Coutes cW Ave. NW. Ste
200. W" OA. OC iw a.
t; r ' • ,i•1 ' ' 1 111, 'N'jbj l•I t 'i l Ij
i
bp,
IEQUIRED E
',MAXIMUM. 48” MAX-
pl1 B
A
LY).
HIP TRUSSES
DETAIL OPTIONS
WEDGE OR
t 'BEVELED TOP
j
PLATE UNDER
JACK TOP'
CHORD
it EXTENSIONS.
i
i
CONNECTION OF
LATERAL BRACE IS
BASED ON BRACE
j
FORCES DETERMINED
BY THE BUILDING
DESIGNER.
BEARING SUPPORT FOR TOP CHORDS OF END JACKS
WHERE THEY GROSS SUPPORTING MEMBERS.
1. FOR REACTIONS OF 300# OR ESS THE TOP CHORD MAY BE TOE -NAILED
TO THE SUPPORTING MEMBER WITH (2)1 Od NAILS.
2. FOR REACTIONS GREATER THAN 300#, THE DETAILS BELOW MAY BE
USED TO PROVIDE ADEQUATE BEARING SUPPORT.
3. SIZE OF WEDGE, BRACE OR BEVEL CUT IS DETERMINED BY THE
REQUIRED BEARING AREA (OR LENGTH) AS SHOWN ON THE INDIVIDUAL
TRUSS DESIGNS.
4. FOR EACH DETAIL BELOW THE TOP CHORD MAY BE TOE -NAILED TO THE
SUPPORTING MEMBER WITH (2) 1 Od NAILS.
6. UPLIFT REACTIONS, IF THEY EXIST, MAY REQUIRE ADDITIONAL
CONNECTION CONSIDERATIONS IF THEY EXCEED THE VALUE OF THE TOE-
NAIL CONNECTION.
S. OTHER OPTIONS MAY BE USED AT THE DISCRETION OF THE BUILDING
DESIGNER.
7. REFER TO OTHER DETAILS FOR SPECIFICATIONS RELATING TO A HIP
SYSTEM THAT ARE NOT SHOWN HERE.
U mIU I LAU Ur Ut I AILS SIIUWN AUUVci. LF_OGER MAYBE ATTACHED
PIAILS. SPACING OF NAILS IS DEPENDENT ON LOADING CONDITIONS
LDING DESIGNER.
SHOWN ONLY. IT IS NOT INTENDED TO REPLACE OR SUPERCEDE ANY SIMILAI
DETAIL THAT MAY HAVE BEEN PROVIDED BY THE BUILDING DESIGNER. IT Is
THE RESPONSIBILITY OF OTHER$ TO VERIFY THE'ADEQUACY OF THIS DETAIL
IN RELATION TO ANY SPECIFIC PROJECT, AS TO ITS APPLICATION AND INTENT
APPLIED q THIS CTI ANY SIMILAR ISSUE. TRUSWAL SYSTEMS ASSUMES NO
R@SPOi:."!. WLITY PCR FIELD INSPF.CT'ION OR WOMI(CAANSHIP QUALITY.
0
END OF
LATERAL
BRACE.
(BRACE MAY
OVERLAP WITH
TRUSS CHORD -
NAIL CHORD TO
FACE OF BRACE
WITH (2) 1104)
BEVEL CUT ON TOP
CHORD OF TRUSS
OR"SECONDARY'
TOPCHORD
MEMBER. NOTE
THAT HEIGHT OF
TRUSS MUST ALLOW
FOR THIS.
HJA
i
BEVEL CUT ON TOP
CHORD OF TRUSS
OR"SECONDARY'
TOPCHORD
MEMBER. NOTE
THAT HEIGHT OF
TRUSS MUST ALLOW
FOR THIS.
HJA
q tJZAVITR W SETBACEt 1'rllss ID: RAF -4
Qty: 1 Drw
,C 1JR0 7x4 FL N1 & Btr. Plating spec ANSI[/TPI -11995 UPLIFT REACTION(S)
i THIS DESIGN IS THE CCtiPOSITE RESULT OF st{:port 1 -12011
MJLTIPLE LOAD CASES. s poyt -1pry(
DER 2x4 FL N1 & Btr. PLATE VALUES PSR ICED RESEARCH REPORT #1607. This Yniss is designed using the
TING BASED ON GREEN LLNBER VALUES. Perlrertcit bracing is required (by others) to UBC -W Code.
prevent rotaticn/tapplinngg. See HID -91 aril Bldg,Encl =Yes, End Zane = No
ANSI/TPI 1-1rA5; 111.3.4.5 and 10.3.4.6. Hurricane Ocean line = No , Category = C
Bldg L.en
99
Bldg Bldg llidth = 30.00ft,
Mean roo ight = 18.32ft, MPH = 70
(: Classification = 4, Dead LbM = 12.0 psf
tOAD CASE H1 DESIGN WADS
Dir L.PIf L.Loc R Plf R.Loc LL
TC Vert 30.0 99--10--103 130.0 11¢-1 12 .53
i„
UVIN Read all notes on this sheet and give a copy of it to the Erecting Contractor.
TBF : 29.3
WO: LLM10
;n is for an Individual building component. It has been based on epecificn6pro provided by the component manufacturer and done in
e with the current version of TPI and AFPA design stacdaids. No responsibility it assumed for dimensloml accuracy. Dimension ere to be
114-12
Customer Name
Y the component manufacturer and/or building designer prior to fabrication. The building designer shall ascertain that the Inds utilized on
n' 1
2
n meet or exeeed the loading imposed by the local building cele. It is assumed that the top chord is laterally braced by the roof or floor
and the bottom chord to laterally bmced.by a rigid shendniog material directly attached, unless otherwise noted. Bracing shown is for lateral
TC Live 16.0 psf
i.
s
TC Dead 14.0 psf
VAa--S-
a--S-4-1-1
f the wrod exceed 19% andfor cause connector plate corrosion. Fabricate, handle, install and brace this trues in accordance with the following
'TRUSCOM MANUAL', by Trusvwl.'QUALITY CONT OL STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES' -
BC Live .0 psf
0. C. Spas i ng 2- 0- 0
IfANDLIN0 INSTALLING AND BRACING Mf. rAL PLATE CONNECTED WOOD TRUSSES'- (1110-91) and '1418-91 SUMMARY
8C Dead 10.0 psf
Design Spee UBC -97
by TPI. 11- fame 1"ate Institut, rTPll 1. lnrnt-A„ a,,, rt•, •.... r,t. n.r.._ ..,•r.,,,, n ,t.r,,,,.te W119 rk-
4 1-1
SHIP
1
10.3 12
9)
, 1/2" GAP MAX
f1 ` 2-9-15
2-0-0
` "P 1 r,i":. ,jj1 •-!
- '
11-3-7
,. , .• ,, a
4
3/15/99
lsual Systems Plates are 20 ga. unless shown by "18"(18 ga.) or Scale: 5/16" = 1'
(16 a.), positioned per Joint Report. Circled plates and false
tone pfates are Dositioned as shown above.
UVIN Read all notes on this sheet and give a copy of it to the Erecting Contractor.
TBF : 29.3
WO: LLM10
;n is for an Individual building component. It has been based on epecificn6pro provided by the component manufacturer and done in
e with the current version of TPI and AFPA design stacdaids. No responsibility it assumed for dimensloml accuracy. Dimension ere to be
Chk ` •
Customer Name
Y the component manufacturer and/or building designer prior to fabrication. The building designer shall ascertain that the Inds utilized on
Dsgnr: NLC = 5
n meet or exeeed the loading imposed by the local building cele. It is assumed that the top chord is laterally braced by the roof or floor
and the bottom chord to laterally bmced.by a rigid shendniog material directly attached, unless otherwise noted. Bracing shown is for lateral
TC Live 16.0 psf
DurFaes L=11.25 P=1.2
f components members only to reduce buckling length. This component shall not be placed In any environment that villi cause the moisture
TC Dead 14.0 psf
Rep Mbr Bnd 1.00
f the wrod exceed 19% andfor cause connector plate corrosion. Fabricate, handle, install and brace this trues in accordance with the following
'TRUSCOM MANUAL', by Trusvwl.'QUALITY CONT OL STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES' -
BC Live .0 psf
0. C. Spas i ng 2- 0- 0
IfANDLIN0 INSTALLING AND BRACING Mf. rAL PLATE CONNECTED WOOD TRUSSES'- (1110-91) and '1418-91 SUMMARY
8C Dead 10.0 psf
Design Spee UBC -97
by TPI. 11- fame 1"ate Institut, rTPll 1. lnrnt-A„ a,,, rt•, •.... r,t. n.r.._ ..,•r.,,,, n ,t.r,,,,.te W119 rk-
. -. - -.-._..ter_.__--.: ._ __—_- __v _ - •
`a c• r = :ji.:.-:s-rh^ ^Wy,•p'S"G t+ZcF -'LST Y'•.._: ''ti-' n-' .— a•yL--_:-`atls ." c.,':,_.tam!_f+4w+ i Via. _
_
. _._,._-._ _..,_.-.._._r- • •• ._-_.. - _ _ -- — - awe_...: — - _.: _.. _ - -- _ __ _
_.. ._.._ ... _. __ -._.._ .... .. .._
i
C ' FFAM!NC P_Iw
CXfC: HIP SYSTEM
H\ I E14D VIE14
../1 it Ali % r :• ice:
✓ t Y Y 7 y 1 i— f i i
CD
ADEVttATE-HANCER OR (2) 16
(2) dbd'NAILS \
TUE-NAILED
mI
1 \ A
TRUSS'PLATE.OR (2)'16d NAILS
(2) 16d -NAILS END -HAILED
SUE -NAILED
A - DUTCH HIP GIRDER
B - 2x NAILER (BY OTHERS)
C - END JACKS
D - CORN:'R JACKS
E - CORNER JACK B.C. WEDGES
H - HIP RAFTER
R - BLOCKING FOR DIAGONAL BRACE
X - DIAGONAL -BRACE
JACK OPTION 1 JACK OPTION 2.
DIAGONAL BRACES "X" ARE REQUIRED AT CENTERLINE AND AT 10'-0" O.C: FROM CENTERLIN$?
BLOCKING "R" IS REQUIRED FOR EACH DIAGONAL BRACE "X", ATTACHED WITH (2)16d NAILS;, ' ,Fg?;;;•;4;
END NAILED INTO TRUSS TOP CHORD. LOCATE BLOCKING AT TOP OF DIAGONAL BRACE `=
AiND._.IN nrTWEFN NrXT TRllSSES: FACH DleZ'C
T AN C-3-BLOGK-S-TOTAL)-BLOCK,--
'^-FSE-$••3Enm'+=# I'Bc ,, as A n 1c 0 y-►ui gE=t1SE8 ..`i<+E1=Pfi0uiDE t i, r-am- •- --
t"DEs-ir-tays-- ,) VT- Iarl r _
_
.=—aTHa-a—a : s-•-NOF--sxas . .n : .x_• ----._: _ _ _ _ -- _ _ _
NAILING_.IS' BASED. -'ON AN 8-1 0 _.114%TNttH c>=•rn. e eNn cn-vc: <evTui - '+'•-^^ -
- , Tom,•.. ..,,... ,._--- - ."
i
x6) _
XR) MAXIMUM 1'-0' EAVE W1T4 — F
BLOCKS @ 32'o.c. OR 2'-0' EAVE,
6'-0" MAXIMUM MAXIMUM. WITH 4x2 #2 OR BTR.
BRACE SPACING OUTLOOKERS CUT INTO GABLE @ {
32'o.c. y l
I 2x4 BRACE
2x4,12 MINIMUM CONTINUOUS
STRONGRACK BRACED TO ROOF
STRUCTU;,E AT 6'-0' MAXIMUM. .
STRONGBACK AT: 2x4.STRONGBACK BRACED,.
4'-10' CLEASPAN, 70 MPH AT EVERY 6'-0' MAXIMUM
1.5-3. TYPICAL \ 4'-1.5'CLEAFlSPAN, BO MPH
CONNECTION.
MINIMUM GRADE CHORDS AND
STUDS 2x4 STUD/STANDARD,
STUDS TO BE MAXIMUM 24'o.c.
WALL BRACING PER BU
DESIGNER.
HEEL PLATE: 3.4 (2x41
5.5 (2x6(ILI
— — " 6.6 (2X61
CONTINUOUS BEARING WALL I 2x4 CONTINUOUS SACKING
WITH 16d NAILS AT 24' ox
TO THE WALL PLATE.
i - SECTION A -
GABLE END FRAMING CONNECTION DETAILS (MIN. NAIL HEUUIREMENTS SHOWN)
I1 GABLE STU 1
2.x4 SOLID BLOCK WITH 3• I6d NAILS Bd AT 6" o.c. "
SHEATHING TO GABLE EA. END AND Rd NAILS FROM SHEATHING / _ '
TRUSS, Bd AT 6' o.c. TO BLOCK At 6"o.c.
ij
If
`t
I '/.' NOTCH 32" o.c. 1 SOLID BLOCK 4 ;vim ', t r , 1.•
\ WITH 2.16d TOE. :.'w i'-dY 9• ; a .. .l
2-164
2x4 BRACE NAILED EA. END ` !
WIT}I4-16d NAILS • t5;'i% % "^'"
A.
'.IPIG DATE "
WARNING Read all notes on this sheet and give a copy of It to the Erecting Contractor.
I U OUS 2/1 1 /99rhil deskpt Is for An individual buildesq componen component. It Eras been based ospetierallms, provided by the compo—t manufacturer and done in
accordance with the cunenl versions of TPI and AFPA,desgn standards. No responsiberty Is assumed (of dimensional accuracy. Olmensrons are
16"'VVV to he verified by the component nut-feetwer and/or bud" deegner Prior to fabrication. The building designer Shan aseenaN that the bads
7 p ufairnA on fit's design meet a exceed the loadingknposed by the local budding code. It is assumed that the top chord Is laterally braced by Na
,lois nro/ nr crux shoefNnq and pre bottom Gard Is laterally braced by a dgld sheathing material directly attached. unless dlferMse holed. &a"
11- n Wr lateral sUppnn of components members only to reduce bucidirtg Its Vh. This component sham not be placed an any eAvkonmenl thal
" ' ® ) .•ill raun the nglsture content of the wood exceed 19% and/or tuouse coriewciw Wafa corrosion. Fabricate. handle. hstas and once this truss in
1111 Y,,'p1N, CJSrf.IAS CCInT'!]lsniulN 0h law Idtowng nendards: JAUSCOM MANUAL' by Tnrswas.'OUAU fV OONrhOL STANDARD Fron METAL PLATE CONNECIEC
n
fel , 4 1. bell'
• - J
Alternaaie Stud Contivction vath Staples,
\ 'fes. Stull
NUTS; Vent Ulocke may br omiRed \\Corm ection
{i where no vent Is required. \ DESIGN FOR TYPICAL CAULS END TRUSS
Il I
i4 U•)l, T-34 8 algal x I;I
jI" Crown
I 1 /l"Ione
I; Y
iI, g
D-7.5/1 T-31 or equal
N
I > 'o I u
1
IMI i
I1j o.
a
!d
113 4. T - ]l
e e
Ili
outlooker
/ilald Rat Cutout for 21:i laid flat
bulldine lansI (Spacing per butIdir,Q plans
ff
Ixt Add-on t_
41 with Ild na tI s at I Ob. c.
t (by builder)
)UTS "ON STUD"CUTOUTS
DETAILS FOR 2 x ! OUTLOOKERS
2-10d nails
12
varles
GAI]LI. END TRUSS
D -7t, T-lt
2-I6d nail
Plate Llne.f/'
GABLE END BRACING
• - - 1.
t rco.-ci On/11n1. '«. .1 ..-... . ..+r ro.,.. 1. ,..1 1 -..:.+.w....-.1 .w ......,,o.:.... .. w......: ruurKN-4.rv...uaeu.r ...a. .... r..,..w.....
V..v >DIN.wM wY M•A+'TI:IIwa/ N,ti„1r.II-b..•1,wA... .n/..I n.•,Hwoo w.l0', J{-.. M•h+r. yaw. wMawv.n..PaK O. w.fow eti... ..Nu .r M ,.,.•t
Wsh..l.JawN Mrs+-Q1: r.nNM.w„h",.10'ati Iwr.IwN1.M..11-•,, ww N.w n.• 1 q'.+'w ✓...maw••. f1N1{MOt:lfl /al O Ia.AR MweKI
A WOI.•w M H a.l. 11-1: 10 ..... N N G...11^ . JI- bti I...w v. ww,n.11-.o H M4 . ,11 ..11- •.l /.o.,.... iw 1:w. 1 %_ •°' —.. 11 I...eA Iwl A/ MM ✓. M M
k, By: ; ny ir ...o•oI .10Woti a.n_.w. ✓..+M1..,wrlw.4..w+ . r.
AA 100
1
ANAHEI
D E,M OI
ATLANT
O
FSM
PLAN.V)EW A
DETAIL A
CENTERRID{',= .
P,AFTER I
VALLEYnAFTER
('YP )
f r
2 -16d /
TOE NAILj:r2 2XIEILOCKW17.1.i (TYP)
4 •]6d
PLAN V1;W
fFii1SWA • SY$ EF S 6R -... .... _ - _ - _ _ -___ _ --_ . - —
s
-
.-T- ?, .5 5 SR
D VALL E "Y" SETS
Notes:
The maximum Total Top Chord Load = 48 PSF
TRUSSES @ 24" O.C.
Minimum Top Chord Dead Load = 7 PSF
The design for lateral loads and their connections is
GIRDER DESIGNED TO SUPPORT
the responsibility of the Building Designer. The details
HE 'TIE-IN' TRUSSES \
provided address gravity and wind uplin loads only per the UBC.
The *maximum wind speed is 65 MPH, 25 n Mean Roof
B
Height (max.), =xp. C.
160 box nails :re t}7icnl throughout, except as noted ( in details ),
The Center Ridge Rafter ( CRR ) is 2 x 6 stud. Attach (his Io
C
the 1 x 8 with 4-16d toe nai!s ( 2 from each face I. Arach (he
Opposite and to the truss the same.
ELEVATION VIEW
The Valley Rafters, purlins, and blocking material are 2 x 4 stud.
The blocking must be spaced 24' O.C. and be adequately braced
in the lateral direction at 6-10.0 O.C. Attach this blocking to the
Valley Rafter with 3-16d. Attach this blocking to the purlin with 2-16d.
The trusses below the valley are spaced 24'0.0
The purlins are full length under the valley set and rnusi be installed at
24' O.C. They are to be anached to each over!apping truss lop chord
with 2-16d nails. If they are not one continuous length. add a 12' long
nailer to the face of the truss (op chord with 4-167 end one purtin section.
DETAIL 5
on the In :s and begin the additional section on the nailer.
VALLEY RAFTER
A 1 x 8 perimeter runner must be anached through the sheathing and into
each truss below• with 3-6d box
nails. This 1 x 8 folio--ssthe outside ptbrrl e
Of the valley.
t
The Valley Rafters are spaced 24' O.C. Arach them to the CRR with
1 5'
2-164 toe nails. Anach the opposite and to the 1 x 8 wilh 3-8d toe nails.
2 X 4 BLOCK
PLAN VIEW . WITH 3 - 16d
F C1
_ r - --- _. ...a.,--._...., ,--.---• _-"'___ '- .:LL's• - -1> .-- .=.o.. -.. @,,...
RECOIMI ENDED CONNECT.IO*: DETAILS
THESE DETAILS ARE INTENDED:TO SHOW MINIMUM REQUIRED CONNECTIONS RECOMMENDED
BY TRUSWAL SYSTEMS. THE DETAILS DO NOT REPLACE OR SUPERSEDE ANY DETAI7-6
SPECIFIED .BY A PROJECT ENGINEER OR ARCHITECT ON A PARTICULAR PROJECT, NOR
HAVE THEY BEEN ANALYZED FOR SEISMIC AND WIND FORCES ACTING ON THE CONNEC—
TIONS FROM THE RESPONSE OF THE STRUCTURE TO SUCH LOADS. IT IS RECOMMENDED
THAT THE -APPROVAL OF THE PROJECT ENGINEER OR ARCHITECT BE OBTAINED BEFORE
USING THESE DETAILS. BEARING REQUIREMENTS SHOWN ON SPECIFIC TRUSS DESIGNS
MUST BE SATISFIED, INCLUDING CONNECTIONS FOR UPLIFT REACTIONS.
TRUSS CONNECTION TO EXTERIOR BEARING WALLS
TRUSSES @ 24" O.C. (TYP.)
®A BLOCK
BLOCK BLOCK BLOCK
_q TOP PLATES
® STUDS @
A 16" O.C.
(TYP.I
eSp4 Cyp4tD
BOT
CHORD
i]
SECT. A—A I
TRUSS
(TYP.)
PROCEDURE: _L L -i
1 TOE -NAIL BLOCK TO TRUSS WITH 1=16d COMMON NAIL.
2 PLACE NEXT TRUSS AGAINST BLOCK AND TOE -NAIL TRUSS
TO TOP PLATE WITH 2-16d COMMON NAILS.
3 END NAIL THROUGH TRUSS INTO BLOCK WITH 1-16d COMMON NAIL.
4 PLACE NEXT BLOCK AGAINST TRUSS AND REPEAT STEPS 1 THROUGH 3.
5 BLOCKS MAY BE ATTACHED TO TOP PLATE WITH SIMPSON A35F (OR EQUIV.)
FRAMING ANCHORS. SEE MANUFACTURER'S CATALOG FOR DETAILS AND
SPECIFICATIONS.
TRUSS CONNECTION TO INTERIOR BEARING WALLSRL _
'X' BRACING`
�� B.C. OF TRUSS OR
END VERTICAL RUN
THROUGH TO BEARING. -
WALL MUST BE AT HEIGHT SPECIFIED ON THE DESIGN DRAWING OR �-
1 � c
MUST BE SHIMMED TO THE CORRECT HEIGHT. k_.,, _
USE 2-16d COMMON NAILS TOE -NAILED INTO THE TOP PLATE
THROUGH EACH TRUSS.
DIAGONAL 'X' BRACING IS REQUIRED AT ENDS OF THE BUILDINGiv—
(OR
(OR WALL) AND AT A MAX. OF 16' INTERVALS ALONG WALL.
'X' BRACING IS MIN. 2x3 MATERIAL WITH 2-8d NAILS EACH END.
BLOCKING SIMILAR TO EXTERIOR WALL DETAIL IS RECOMMENDED.
TRUSS CONNECTION TO NON—BEARING PARTITION WALLS
WALL PERPENDICULAR TO TRUSS WALL PARALLEL TO TRUSS
TRUSWAL SYSTEMS
4445 NORTHPARK DRIVE, SUITE 200
COLORADO SPRINGS, CO 80907
(800) 322-4045 FAX(719) 598-W3
1/10/01 Users of Truswal engineering:
C001003160A
The TrusPlusTM engineering software will correctly design the location
requirements for permanent continuous lateral bracing (CLB) on members for
which it is required to reduce buckling length. Sealed engineering drawings
from Truswal will 'show the required number and approximate locations of braces
for each member needing bracing. In general, this bracing is done by using
Truswal Systems Brace-ItTM or a 1x or 2x member (attached to the top or bottom
edge of the member) running perpendicular to the trusses and adequately
designed, connected and braced to the building per the building designer (See
ANSI/TPI current version). The following are other options (when CLB bracing is
not possible or desirable) that will also satisfy bracing needs for individual
members (not building system bracing):
1.- A 1x or 2x structurally graded "T" brace may be nailed flat to the edge
of the member with 10d common or box nails at 8" o.c. if only one
brace is required, or may be nailed to both edges of the member if two
braces are required. The "T" brace must extend a minimum of 90% of
the member's length.
2. A scab (add-on) of the same size and structural grade as the member
may be nailed to one face of the member with 10d common or box
nails at 8" o.c. if only one brace is required, or may be nailed to both
faces of the member if 'two braces are required. A minimum of 2x6
scabs are required for any member exceeding 14'-0" in length.
Scab(s) must extend a minimum of 90% of the members length.
3. Any member requiring more than two braces mUst use perpendicular
bracing or a .COmbination of scabs and °T" braces, or any other
approved method, as specified and approved by the building designer.
. EXAMPLES 2.
90% L
L
90% L
L
M
IV7 r
TRUSWAL SYSTEMS'
4445 NORTHPARK DRIVE, SUITE 200
COLORADO SPRINGS, CO 80907
(800) 322-4045 FAX:(719) 598-8463
8/3/00
To whom it may concern:
It is permissible to repair a False Frame* joint with the procedure outlined below, .
provided that the following statements are true:
• Ceiling loading is 10 PSF or less.
• Trusses are spaced 24" o.c. or less.
• False Frame verticals are spaced 6'-0" o.c. or less.
• No additional point loads or uniform loads are present on the false
`frame that would cause the loads to exceed 10 PSF for any reason.
• The joint(s) to repair does not have a support bearing directly
underneath the joint.
There is no damage to the lumber at the joint, such as excessive
splits, cracks, etc.
• The joint fits tightly (within all TPI tolerances).
• All lumber in the false frame is 2x4 or W.
Repair as follows:
1. Cut a '/z' CDX-APA Group 1 plywood (or equivalent;O.S.B.) gusset, 4° wide
by 8" long, or larger.
2. Apply gusset to the face of the truss at each joint with a missing plate. If one
face of truss has missing plate, then gusset is required on only that face. If
both faces of the joint are unplated, then the gusset is required on each face.
3. Use (3) 8d nails into each member, from each face (see detail below).
* False frame refers only
To non-structural members
(zero design forces).
Typical Joint
J
i.d
+
IlliPl l f N IGI .'I V!
I
i
1 II I I t
I4I1 II 141 'I i' )}Iti ik lll(7 W
jl
Ell
.13E Nl
'',1.11 . trl ' - - :.. o l ! Fi I i :,, I li" ' '!'' ,J{I;I•' .,r41
+i1i1`!1. - MUNI WIND SPEED'[ 85 I Fj.MA3QM' .i: 1.'1i ,. 1•iF'Y'dI'.:C;;.,, i;;,'iPr: 'I (li, j h,;Ll,;i!:Il,•'i.!I 'a, , I',,,,'°► .: 'I'.„;I:I.,iEi I LI II, IiI II .,7I!!i', ..1l i1 H
tcr
1 :,WITH THE2-16d NAILS TOEN
AILED t• I , , 7 j.11 11 t
9 1
CONSIDERED.
I¢ REQUIRED
IRESPONSIBILITY
1 /2
NER. 1 1 " :1' o! , I I '1 1 • I ' ' I
J!II; I
1 1
i
Ir . {
I .. 1 'I I ! 1 i ' 11 - 1. ,, . ;11111'!+1f111114 N71I la•`! i ! . I• j
' 9 jjj i rl i 12x4 BRACE
12 I l ! n f1 I!
I I,' r (j Y rll. SII I j 117
I 'r
pl 1i I'llti'
BOTTOM TRUSS
,, 17111 1c, 'i! II I. , i'I!1 i• :,A;'':I ) I ;ii• 'j$:.I 'ia II L!I 'i 1:
it ,k
{ II I i' '1 I 'ir' i RI Irl
REFER TO THE APPROPRIATE uv J II I G 1• 1 ! Ji II t
ii1 j la• Ij TRUSWAL OESIONS FOR THE I h ylj ; 1+ d1 iil Ipjt_ ;,
I" ! V'liii 1 i•l, sJ . I ; ''i rI1 llI 9I REQUIRED WEB CONFIGURATION
FOR BOTH THE CAP TRUSS AND'
- . '',T..• I, : , '..I.!;:I.•;r II.: , !1i L., i...., ii1 ,:' tI . . .i ,:,i.{,.I, .!,: ..:i.l., Li1. j'p! ; :1 o, 'f' .' I.
THE SUPPORTING BOTTOM TRUSS. ' Ia I'!
) ii t l
,I 'I1 ,I '1•il:dy :i;dPilil- lII° r ' ;111;1:j)!' ' 1°, :
' (;f
I I I D ti
I I j til 999 1 iI I I
i,. ' Irlwr •r : III; 1'I 9.. II i1''1 !:I ! ;;i.
2x4 CONTINUOUS LATERAL'.
CHORD/WEB SIZE ARE i5zit J 4 i I I I{
I I I +
BRACING APPLIED AT 24"o.c.' F "`• `- twl Jr,?' r I '
)I j' a PER THE APPROPRIATEI tti r b I t I I I 'I
j,.I II ATTACH EACH BRACE TO THE
BOTTOM TRUSS WITH 2-10d
TRUSWAL DESIGN.e A ii ;F111y + hl tI i 1 Lalllll., 1'
NAILS AT EACH INTERSECTION. "try,,1 Il ! 6.141It' pr I In"`I'
TOE -NAIL THE CAP TRUSS O '••' =•.' I,nt l ,a.
i 116 7 t; gII`II T`,i l r t'! •'. , , ( v. '., T .t✓ , . r I , 111
THE BRACE WITH 1-1 Od NAIL L
FROM EACH SIDE AT EACH
INTERSECTION.11'I . ti' '.I ! r I i {• !f' v`l ,I b:i I. ji!III
I l:i fl {1 ;'t . . i Ij c,j} + 411 , tt''1 I :q'' 1 I il' I! •I ';I!''
m Pr :I
?, :1. t, i
{.
01 ,. 'sRgclrfa OArE
. ; ; :I, i I Ij I ,I i'.•? I<< ! II'' ',)j"s i Sill I
WARNING Read all notes on this sheet and give a copy o! it lo'.I„ re}i
This design Is ra an Individual Ouildmp component. it has been oared on spea0cauons provdedl e
®® .d ® accordance with Ing current _,00ns d TPI and AFPA design standards. No respons.,t _ i li fit'
7p I•'1 , J ✓' b ,ty is assum
° tJ L? ! Iq• , I. 4-30_98 _ to be vari0etl Is too canponent rnanutacturer and/or building designer prior Io laodrat.on, Tne'o q deo.1 s, x II41
b ALuteited on tlws design moat a et, the loading hnIl led by the local budding code. It is ail,. tial IM'
' s,: o. .' !. :•; I I
cool or Ibor sneelLm end the baton toad Is laterau bareo o a d A sneetni I " i 1
g V Y c ng material duIncnntl,. nt
Shown if roc 18terai .0 pod o1 Cmnponr7nls member only Ip roUUCe buGepnq length. Tn,9 [:m .,. ptiaa not Ori PlTtbl yl,'vlvlro'n,p .IIya1' I t „ 1
IC ION DETAIL ® ® . 3.y7 "•Ili wase die mdho to contact ta the wood exceed m and/or cause connects prate c oN rR . F atA Mfidle'`hdT hlgcai I i h,
at:CorJarre with rho FolbwMg standards: 'TtiUSCOM MANUAL• ny Truswal. 'OUALIfv CON TFIOL yiAt/0A110 r OT pt, T r;,
I IRUSWAL SYSTEMS CORPgftAflpN A „! W,,
WOOD TTIUSSES' - (OST00). 'HANDLING INSTALLING AND OMCINO METAL Pli1tE CONNg T ypgLl,; SEgi6.It^•a'! o. i
SUMMARY SHEET by IA. The Truse Pwe Inslitute (TPI) is located at 507 O'Onohlo Drive, M tl 1 p Ofi Ar.. ,fy[, MI f I,s,{• ' I• 'I
CO Paper AssoClatbn rAFPA, la located at 1250 Conn Mlcut Ave, NNY, Ste 200. Wasningto UG . ' yL J 1 :I''1
"- I Itu I 1 4J I -•'vR 11 r ! Ir. dt:i ,I 1, ' /( ., II1 '!I ,
Y !
j'
41 111 I I 'i:.r
n{I7 1'i•ll!H If 'T,I. r n 'II .Fr I r
.
^ m 72 O.C. TYP.
(2) 16d TOENAIL
-liq
,
.
/
CONT 2X4
SUPPORT TRUSS —/ —1 /2' 8' / —
AT EACH END OF TRUSS
' ^ '
!
5—C[ O.C. FOR
LARGER) ATTACH
SPANS JO' AN
WITH (4\
i
'. LONG
` '
8d NAILS.
USE 2X4 AS
ALTERNATE WITH (4) 16.d EATill
111630 el -S-3)
Ij
16,30
32
45
1. 5X3
1630 SP3260
2X4 CONTINUOUS SUPPORT BRACING
-ATTACH TO THE TOP SIDE OF TOP CHORD OF
TRUSS SUPPORTING PIGGYBACKS WITH (2) 10d
NAILS 4.
ul
Ty . GowJec-Tzo/AJ
=o ►2- G y - 3tt-Gly P Thu S .S
M PSC, V P 1,5-- = 12o S #t- v F Chro ...
}X. SticA 2 3(,S PL -F- tfo2=Z- o(2-
7304-- (z -F Nor 2,411o. c,.
S=rtPseN
s-r7ZoNC - C
LS7A 2-1
S1 _/ffl - G
(3y oTrieg-s)
Q Pc-S 2uS S
za-" o, C-
A -,=- r) i , 1)0a r,G
SSMP J
TeoN v - -rr,E
A34
TOP "0 GOT -MM,. EnK-+ S
Or- 72-0SS , 5 4- 4 SPA -C- -
I
I
I PRESSURE BLOCKING DETAIL FOR END JACK BOTTOM CHORD
UP TO 10'-0" AT HIP NO. I `sVITH CEILING LOAD OF 5 PSF
1
HIP NO. 1 TRUSS
;BLOCK i',nESSURE BLOCK `
l NAILS 3-10d 3-lod 1- \ SIDE VIEW
WITH 4-16d NAILS 3-10d
M. END JACK
BOTTOM CHORD OF
HIP NO. I TRUSS PRESSURE BLOCK
PICAL 3-10d
i r..'., •.rte..',' 4•.y.
;12X4 DOUG R PRESSURE BLOCK TO BOTTOM V? ~ ,,: " (5
'OF HIP NO. I WITH 4-16d NAILS. BOTTOM
I OF END JOINTS ARE ATTACHED WITH 3-I Od ` "(•}- •.~ 1
EACH END OF THE PRESSURE BLOCK.
9
I
I
Oa TE - - - - -
II IS "rI "I"ollSI01l1i. Or O11KPS In..SC(aI.IN "r.l IM lO•Os VIILIICO ON IRIS 0(510" MCI Oa [ICE(C) r.K
i S/I 5/97 1C+V.l VE.. Mus Iwo0St0 OI "K SIIII,C Iunr. .1,0 I•K llvl 10.05 IwPOSEO e. Irt IOC•l eult0nlc COM 04
ul51nr11Ul CUw.11C nC COn01S. tro IKirp,i l0ILI" IS .Ssuoto 'On 0111["SIa1•l •CCUniC• v(alr/ al
VIM.'r; IarS n11Ann l0 I.B41C.Itp1 C9,nKC10n at.I(S snow" .n( 1nuSv.l 16, le. Oa ?o t.cr, .S So(C II itO
. 1. I.OnICL 1pl u•ll Co•rll w1 t,.r.11 AuALI'It Ca11a0( w.IK,.I• Or WE IaJSS n1•1( IlISII1Vl( I1r(I .fro I -K
I nUSwq. InuStnv w.lal.l .11 PUICCS Iql SrCC IIIUII• OtSltn. I(0 an( IO 0C COV111 r 01'f 10[0 .C1 0Ur01(S
snl Cl+l Ol11 Art S 11 1101, en.0 hT, IKOVIaro O• 11101v10W1 Ia1ISS MvOfnS IS rplt0 O1• Irr1S Onrrl"t
X1115 Il(SIt11 .S Vur; 11'C Ipr Cllnrlp 10 0l CO, i1U0USt Bn.CFO kPOLM 01111av15f S••ItV r•?a'
I nV n11; 111 rJ II it Is 0"I IIV nPN.CII, 10 Wr oolio. C11onU. It Y t eC en.CIo -1 Irnl nvg5 vV' [.C1101'rr.
IPur; I r, n. nsa,5 lu((l Art nr,SSls .uf C.U110•,/U 10 Sfl. mrorTSS19•I1l .QviCl IKt•1K111,t rt-.rgo,n, rNC1 a,
-.I1 I, .(wns ntmn n4o 10 nnf v(r" ronnt P, oro oovi•rolnt a(r1n 10 •gnrC I, I.
Iaussls
y, vnv• QpJ1.7 cnN (ni.nr q nCCu M•.nU.Ilpr; TIMI ."t nr co'nu;Ip• ,Iv Ccm Cr. rK oorlo rlllV rMClUS
CI t•nI N.nr IN17.nIon er .n llK cOC.11als. c.'n ll C•Q as. ,.n0 n4 clronOs a Ir•t 1rVss +o onl .l •,I lroapota
TRU_WA SYSTEMSCORPORAIION ",1, (.Ila, rousscs S"4l 'al off nl.ct0 r, ..,1 (rr1(oo1 r -n 11nr rul oust 1.1-alslunt (0.11(11 01 r11[
' J1N YC 10 1'
191 .Nn: un C.us( Cp11n U(wl P1.1( cona05I0'1 uwB(o, 1Nr(„ ,q ((S;.n.. Is E[sr aICa1't'rt0 e•
j' 7IC.'lar 0• l.rfal[.KC .110 1-K •Kf On( IS 0uts10r I1K SCOat W.acsno"s teltlrr Of IaVSwrt
,191 ii, lih
END JACK STANDARD DETAILS (CALIFORNIA STYLE)
LUMBER
PER OPTIONAL EXTENSION
i'ir SIGNS.
I` 3-4
A
i"
HIP GIRDER CHORDS
I B
CONNECTIODETAIL "
N
I, (BOT CHORD TO HIP GIRDER)
LUMBER REQUIREMENTS:
JACK TOP CHORD: 2X4; 172 OR BETTER DF -L, #11#2 OR BETTER CAN S -P -F, #1 OR
BETTER S -P -F, #2 OR BETTER HEM -FIR, OR 1660F MSR ANY SPECIE
JACK BOT CHORD: 1X4; #2 OR BETTER ANY SPECIE, OR 165OF MSR ANY SPECIE
:1 CORNER RAFTER: 2X6; SELECT STRUCTURAL ANY SPECIE, OR 165OF MSR ANY
SPECIE, OR DOUBLE (STACKED) 2X4 PER OTHER STANDARD DETAILS.
TOP CHORD LENGTH MAY VARY FROM 6" MINIMUM TO 8'-0" MAXIMUM, WITH
EXTENSIONS SUPPORTED AT 48" O.C. MAXIMUM' - EYOND.
TOP CHORD MAY BE SPLICED AS SHOWN, ABOVE THE HIP GIRDER ONLY!
-BOTTOM CHORD LENGTH MAY VARY FROM 6" M17:!IML!M TO 8'-0" MAXIMUM.
-DO NOT SPLICE THE BOTTOM CHORD.
-TOP CHORD PITCH MAY VARY FROM 4112 MINIMUM TO 8/12 MAXIMUM.
-BOTTOM CHORD PITCH MUST BE FLAT (0112).
-THIS DETAIL APPLIES TO 45 DEGREE HIPSET JACKS AND CORNER RAFTERS ONLY!
CONNECTION DETAIL "C"
(TOP CHORD TO RAFTER)
1'1
,11 'i .t JACK TOP CHORD
I 'DER
7\ -
MUST BE SINGLE
BEVELED OR
I) 1 DOUBLE BEVELED
;; ": 10dor 1Gd NAILS, THROUGH
(2) 10d or 16d NAILS EACH JACK T.C. INTO RAFTER,
i' THROUGH JACK B.C. INTO TOE -NAILED, PER SCHEDULE
j 11II I GIRDER BOT CHORD, TOE- BELOW, OR ADEQUATE
Illy NAILED, OR ADEQUATE MECHANICAL HANGER PER
MECHANICAL HANGER MANUF. CATALOG.
NAILING REQUIRED:
PER MANUF. CATALOG.
2'-0" 3 4'-0" JACK T.C. (2) NAILS
M CHORDS ARE USED (INSTEAD G'-0" JACK T.C. (3) NAILS
I Y MAY BE ATTACHED TO THE 8'-0" JACK (ONE FACE OF 11 RAFTER ONLY)— - 4) NAILS
TEND JACK AS PER DETAIL"3_ -- --
14, 2S.iP=11.25 DESIGNED I -OR 10 PSF NON-CONCURRENI BOTTOM CHORD IJVE Lw.17.
I` ' PLA I'ES 8 NAILS DESIGNED FOR GREEN LUMBER VALUES.
n n,t+s
WIND LOADED FOR 75 MPH, EXPOSURE "C', MAXIMUM.I't.i NO POINT LOADS. MECIIANI<:AL UNITS MVAC, SPRINKLERS. OR UTI
ni U8G9r ITEMS CAUSING ADDITIONAL LOADS ON THE STANDARD JACKS IS
Ji i!
ALI_UW[D. WI'IIIUU f SPECIAL DESIGN.
M111 I'll
! j i THIS DETAIL IS PROVIDED AS A SUGGESTED SOLUTION TO THE APPLICATION
7) - SHOWN ONLY. IT IS NOT INTENDED TO REPLACE OR SUPERCEDE ANY SIMILAR
5' DETAIL THAT MAY HAVE BEEN PROVIDED BY THE BUILDING DESIGNER. IT IS
I,
THE RESPONSIBILITY OF OTHERS TO VERIFY THE ADEQUACY OF THIS DETAIL
IN RELATION TO ANY SPECIFIC PROJECT, AS TO ITS APPLICATION AND INTENT
#7 7 APPLIED TO THIS OR ANY SIMILAR ISSUE. TRUSWAL SYSTEMS ASSUMES NO
GI .:I RESPONSIBILITY FOR FIELD INSPECTION OR WORKMANSHIP QUALITY.
1 -PLY OR MORE GIRDER
B B B C A
C B' B
C
RAFTER
C
/41
O. 4598 :]
s /Exp. 12/31/O2
E 0 /' CALIFOP
ES:
4/6/01
EJ -1