Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0082
52830 Avenida Martinez BSOL2015-0082 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of Ehu,,ness and Professions Code, and my License is in full force and effect. License Cla : C4 B C10 A Licen o.: Date Q/ Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the o ractor's State License Law for the following reason (Sec. 7031.5, Business and Pro ssions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property'who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' mp ns ' n, as provided for by Section 3700 of the Labor Code, for the performance of th w or which this permit is issued. have and will maintain workers' compensation insurance, as required by 00 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agreetbat,' hould come subject to the workers' compensation provisions of Se ion 3 0 o the bo Code, I shall forthwith comply wit hose rovisions. Date: Applicant. WARNING: FAILURE TO SECURE WORKERS' COMPENSATIN C VERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALT D CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances a ate I s r lating to building construction, and hereby authorize represe ativ of is c t ente upon the above• mention d rope y or ins pection purpose Date: gignature (Applicant or gen C& a& QUM& VOICE (760) 777-7125 E 78-495 CALLTAMPICO a D FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 7/21/2015 Application Number: BSOL2015-0082 Owner: Property Address: 52830 AVENIDA MARTINEZ REBECCA ANDERSON APN: 773332005 52830 AVENIDA MARTINEZ Application Description: 5.83kW PV SYSTEM - (22) 265W PANELS/(1) INVERTER LA QUINTA, CA 92253 Property Zoning: C-- Application Valuation: $12,884.30 o Applicant: Contractor: r ►®+ SOLARCITY CORPORATION SOLARCITY CORPORATION = 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY c7 e 5 ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of Ehu,,ness and Professions Code, and my License is in full force and effect. License Cla : C4 B C10 A Licen o.: Date Q/ Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the o ractor's State License Law for the following reason (Sec. 7031.5, Business and Pro ssions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property'who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' mp ns ' n, as provided for by Section 3700 of the Labor Code, for the performance of th w or which this permit is issued. have and will maintain workers' compensation insurance, as required by 00 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agreetbat,' hould come subject to the workers' compensation provisions of Se ion 3 0 o the bo Code, I shall forthwith comply wit hose rovisions. Date: Applicant. WARNING: FAILURE TO SECURE WORKERS' COMPENSATIN C VERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALT D CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances a ate I s r lating to building construction, and hereby authorize represe ativ of is c t ente upon the above• mention d rope y or ins pection purpose Date: gignature (Applicant or gen DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY• AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT #. CHECK # CLTD BY Total Paid forBU1LPING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION . ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD -RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # mCHECK # CLTD BY Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:i0 Description: 5.83kW PV SYSTEM - (22) 265W PANELS/(1) INVERTER Type: SOLAR Subtype: Status: APPROVED Applied: 6/23/2015 MFA Approved: 7/20/2015 LUR Parcel No: 773332005 Site Address: 52830 AVENIDA MARTINEZ LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 146 Lot: 22 Issued: UNIT 15 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $12,884.30 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 STAFF NAME Details: 5.83kW SOLAR ARRAY - (22) 265W KYOCERA PANELS W/ (1) ABB#PVI-5000-OUTD-US-Z-A AFCI INVERTER [390SF] 2013 CALIFORNIA ELECTRICAL CODE. NOTES „„_j Applied to Approved Printed: Tuesday, July 21, 2015 11:02:38 AM 1 of 3 r7wsysTrms CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE. COMPLETION DATE NOTES E-MAIL LUIS URIBE 7/2/2015 7/2/2015 EMAIL SENT TO ELENA ALONG WITH REDLINED PLAN ATTACHED. E-MAIL LUIS URIBE 7/20/2015 7/20/2015 SENT ELENA AN EMAIL LETTING HER KNOW PERMIT IS READY TO BE ISSUED. NAME TYPE NAME ADDRESSI CONDITIONS CONTACTS CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)848-8920 mplasse@solarcity.com CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)848-8920 mplasse@solarcity.com OWNER REBECCA ANDERSON 52830 AVENIDA MARTINEZ LA QUINTA CA 92253 (760)848-8920 Printed: Tuesday, July 21, 2015 11:02:38 AM 1 of 3 r7wsysTrms FINANCIAL CLIA DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE RECEIPT # CHECK #. METHOD : PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 - BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 Printed: Tuesday, July 21, 2015 11:02:38 AM 2 of 3 C sysreMs Attachment Type, CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLER`. _ 1ST REVIEW REDLINED BSOL2015-0082 DOC 7/2/2015 LUIS URIBE PLAN SHEET REDLINED PLAN 0 SHEET.pdf Printed: Tuesday, July 21, 2015 11:02:38 AM 3of3 11 Bln. # City of La Qulnta BulkUng 8i Safety Division P.O. Box 1504,78-495 Calle Tamplto 4.Quinta, CA 92253 -:(760) 777-7012 —CC&2 Building Permit Application and Tracking Sheet Perinit # _ t3 501-2o 151— Project Address: IV5Owner's Name: . A. P. Number. Adder: 2how MaMV& Legal Description: City, ST, Zip. La Quinta, CA Contractor Solar City Tel ephone: PMie,ctDescription:z-roof mounted solar panels . Address: 3055 Clearview Way. city, $T, zip: San Mateo, CA, 94402 I inverter(s)5 g - Telephone: 650-638-1028 State Lic. # : 888104 City Lic. #; Arch. Eng., Designer Address: City., ST, Zip: Telephone: Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo State Lic. #: Name of contact Person: M e I a n i e' P I asse Sq. Ft.: # stories: # UniV: Telephone # of Contact Person: 7.60-552-0663 Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE # Sobmittal Req'd Recd TRACKNG PERMT FEES Plan Sets Plan Cheek submitted Item Amount Structural Coles. Reviewed, ready for corrections Plan Chcck Deposit. . Truss Coles. Called Contact PersonPlan Check Balance Title 24 Cale& Plans picked up Construction Flood plain plan Plans resubmitted.. Mechanical Grading plan '! Review, ready for correctionmissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 2" Review; ready for correetionalissue Developer Impact Fee Planting Approval Called Contact Person A.I.P.P. Pub. take. Appr, Date of permit issue School Fees Total Permit Fees N v ABBREVIATIONS ELECTRICAL NOTES - JURISDICTION NOTES . A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN r CONICCONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE .LA QUINTA MUNICIPAL 9ka DC DIRECT CURRENT- LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN - POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE • GALV GALVANIZED HAZARDS PER ART. 690.17. J GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT.,MAX• POWER COMPLY WITH ART. 250.97, 250.92(8). O Isc SHORT CIRCUIT. CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR lA kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN CITY OF LA QUINLA TA (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. BUILDING & SAFETY DEPT. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE APPROVED OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE FOR CONSTRUCT(OiV PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE DATEBY SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V. VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LINE LICENSE GENERAL NOTES PV6 ONEELINE DIAL AMAM 1. ALL WORK TO BE DONE TO THE 2013 PV7 ELECTRICAL CALCULATIONS CA # 888104 Cutsheets Attached C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AREV BY DATE COMMENTS HJ: La Quints REV A NAME DATE COMMENTS s s s * s s z * e UTILITY: Imperial Irrigation District rs CONFIDENTIAL —THE INFORMATION HEREIN JOB NUMBER JB-9223716 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: \,,` OI ' CONTAINED SHALL NOT BE USED FOR THE ANDERSON, REBECCA ANDERSON RESIDENCE Jeremy Nguyen . ?•. • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ' . NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook w Flashing Tape 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY O %,*.J PART TO OTHERS OUTSIDE THE RECIPIENT'S MoouL s LA QUINTACA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Clearvfea Way THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA APN: 773-332-005-0 PAGE NAME: SHEET: REV: DAIS San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT WE WRITTEN INVERTER:T:(650) 638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-5000—OUTD—US—Z—A (760) 848-8920 COVER SHEET PV 1 6/22/2015 (888)-SOL-CITY (765-2489) www.ealarelty.aan IV N c v v ;v c a Q 0 r7 00 CN Ln (E) DRIVEWAY Flynt Of House 11 i 0 0 I 0 0 o W I -n O O 0 0 0 0 IW I I CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE2hW BY _z_ ANDERSON, REBECCA 52830 AVENIDA MARTINEZ LA QUINTA, CA 92253 (760) 848-8920 P1 TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V -METER# 1134SR-105901 "PROPOSED BI-DIRECTIONAL METER#_-- CUTLER HAMMER # DG221URB - AC DISCONNECT: 10FT FROM MAIN PANEL - INVERTER: ABB PVI-5000-OUTD-US-Z-A A O AC Inv PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH:180 ARRAY AZIMUTH: 180 ` MATERIAL: Low Profile W -Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 2 Stories LEGEND '- CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN JOB NUMBER JB -9223716 0 0 MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (22) KYOCERA # KU2656ZPA © DC DISCONNECT & WARNING LABELS SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLMCITY INC. INVERTER: ABB A PVI-5000—OUTD—US—Z—A 11 i 0 0 I 0 0 o W I -n O O 0 0 0 0 IW I I CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE2hW BY _z_ ANDERSON, REBECCA 52830 AVENIDA MARTINEZ LA QUINTA, CA 92253 (760) 848-8920 P1 TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V -METER# 1134SR-105901 "PROPOSED BI-DIRECTIONAL METER#_-- CUTLER HAMMER # DG221URB - AC DISCONNECT: 10FT FROM MAIN PANEL - INVERTER: ABB PVI-5000-OUTD-US-Z-A A O AC Inv PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH:180 ARRAY AZIMUTH: 180 ` MATERIAL: Low Profile W -Tile STORY: 2 Stories PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 2 Stories LEGEND '- (E) UTILITY METER & WARNING LABEL 3 INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS [G—)] DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, _ INTERIOR EQUIPMENT IS DASHED 200A, 240V, SINGLE PHASE, 2 WIRES, 22kAiC SITE PLAN N EXISTING BI DIRECTIONAL METER# 1 B4SR-105901 Scale: 1/8" = 1' IN E 0 1' 8' 16' S ESCRIPTION: DESIGN: ANDERSON RESIDENCE Jeremy Nguyen Y '1;SolarCity. u 5.83 KW PV ARRA1, PAGE NAME:- SITE AMESITE PLAN 3055 CleaMew Way SHEET: REV DAIS San teo, CA 9"02 T.(650) 638-1026 F:(650) 636-1029 PV 2 6/22/2015 (666)-SOL-aTY ('765-2469) www.solarcity.cor„ SIDE VIEW OF MP1 NTS r---,\ A MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 52" 24" 48" PORTRAIT 48" 20" 52" 1 24" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI I 180 PITCH 18 180 PITCH 18 STORIES: 2 Low Profile W -Tile ZEP SPANNER BAR CLAMP " DIA BOLT & NUT ZEP SPANNER BAR STANDOFF (E) TILE (E) ROOF DECKING (E) RAFTER FLASHING TAPE " DIA STAINLESS STEEL LAG BOLT (2—j" EMBED, MIN) 1 STANDOFF INSTALLATION ORDER REMOVE TILE, LOCATE & MARK (1) RAFTER LOCATION.PLACE STANDOFF BASE & DRILL PILOT HOLES. 2) CLEAN PAPER AROUND PILOT HOLE. 3) ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM OF ((4) STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. SEAL TOP OF STANDOFF TO ((6) SURROUNDING UNDERLAYMENT WITH FLASHING TAPE q NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 8) REINSTALL TILE. SIDE VIEW 01 MP2 NTS B MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 52" 24" 24" PORTRAIT 48" 20" 52" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOFAZI ARRAY AZI 180 PITCH 18 180 PITCH 18 STORIES: 2 Low Profile W -Tile CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOBNUMBER:- JB -9223716 0 0 PREMISE OWNER: DESCRIPTION: ANDERSON, REBECCA ANDERSON RESIDENCE DESIGN: Jeremy Nguyen So a City. MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY ."; PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA CA 92253D; MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA PAGE NAME: on M teo, CA" 440 Son Mateo, CA 94402 SHEET: REV. DAIS: INVERTER: ABB PVI-5000—OUTD—US—Z—A SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (760) 848-8920 STRUCTURAL VIEWS PV 3 6/22/2015 T:(&%) 638-1028 F:(650) 638-1029 (688)—SQL-CITY (765-2489) www.solarcity.com 2" MAX 2" MIN CLEAR SPAN VENT SPANNING DETAIL DIAMETERTO UNDERSIDE _ OF MODULE NTS 6" MIN. VENT HEIGHT FROM TOP SOLAR PANEL % OF ROOFTG MATERIAL SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS T:7 OF L A Qjjjt4-fA. I SAFE D^ iFL , PTv ED A OSS(-T Rl `v GGTiON FOR 2D BY DATE MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 2013 CPC 310.5 STATES 'TIO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRIC11ONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = 7f*R' WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agop = C*CLEARANCE = (7T*D)*D = (7T*2*R)*(2*R) = 4*7f R2 4*7f R2 > 1I*R2 FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. - ' UPLIFT CALCULATIONS 06.22.2015 ` `,!s ■ PV System Structural Version #46.4 - ;,;SolarCity Desian Software Project Information & Table Of Contents - BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY '" MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape PVSystem Type _ __ PART TO OTHERS OUTSIDE THE RECIPIENT'S SolarGty SleekMount- Spanish Tile Roof _ . . _ _ -Spanish Tile Roof (22) KYOCERA # KU2656ZPA Layers. of Comp Roofing 3055 Clearvlew Way San Mateo, CA 94402_ SHEET: REV. DATE PPERMISSION OFRCITY ISOLARCITY INC. THE WRITTEN Roof Slope .---- --- - -- - - - - - -- -..-- -- - 180 MVERTER: ABB PVI-5000-OUTD-US-Z-A Rafter adn 24" O.C: PV System Module_ Orientation Landscape and Portrait PV Module Area- PV Module. Width 39" _ - - - - 65„ Standoff Attachment Hardwa4i Mighty Hook HDG ST Reduced Ground/Roof Live/Snow Loads Ground Snow Load _ -- pg_ 0 0psf ASCETabie 7-1 Surrounding Roof Snow _. -- - _-. 0.0 psf _ _ -- 0.SCE Eq 7.41 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria WindCode _ _ _ ASCE 7-10 _ __ _ ,. - _ _Design Wind Design Method_ __ _ T Par#►ally/Fully.Endosed Method y - Basic Wind Speed ---- - -V- 110 mph - - - ..Fig 26 5n1A_, urry _-___. ExpnseGateli6l - _ ._ __ _- C----_.__-_-----___-- -_Sec#fon26J - Roof Style ..___. -- Gable Rodf ag. 3o a z1/e/asA/D _--------- Mean Roof Height -_----- ----- _-- .-- h - --- _- _._.- - 25_ft _ _ Sedion 26.2 _ Effective Wind Area. i Module A 17.7 sf' IBC 1509.7:1 Wind -Pressure Calculation Coefficients - - - — Wind Pressure Exposure _ Kz. 0.95 Table 30.3-1 Topographic Factnr _ .__ .. Kzt _ __. -.- - 1.00 _ -_ _ __--. --Section 26.8 _ Wind Directionality Factor_ Kd 0.85 Section 26.6-1 _ Im ortance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 24.9 psf Ext.PressureCoeffldent (Up) _ GCp (Up) _ -0:88 ----- ----- u..- - - ----- - -- Ry. 30 4-21/11/c-sA/e : - Ext Pressure Coefficient Down G Down 0.45 Fig. 30.4-2A/e/c-W8 Design Wind Pressure P y = qb GC Equation 30.4-1 Wind Prure_llp`P(uA - --- — _— -- - - -------21.8 P ------__ _ _ _ _ -- _ -- _ __ Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction. Y -Direction Max Allowable Standoff Spacing V Landscape m _ 72"T T 52" Max Allowable Ca, tilever _ _ Landscape Standoff Confi uratidn Landscape Not-Stabger6d Max Standoff Tributary Ares_ - _T -rib _ , _ _ 26 sf PV_ Assembly_ Dead Load VV -PV 3 Psf _ - Net Wind Uplift_a_tStandoff -. _ _ _- . -._ _ .— . Clift Capadty of Standoff . _ T -allow _ _ -_ _ 350_Ib_s _ Standoff Demand/Capacity DCR 84.4% Max Allowable Standoff Spadng Portrait _ 48" 52" ---------_-__-- 20 --__-- _ Max Allowable.Cantilever _ _ PgrtCalt 24" __-- Not -Staggered Standoff Confi uration Portrait Max Standdff Tributary Area _--__Trib _-, sf_- -- -------—__17 - -- 3 P PV Assembly Dead Load ..._ W-PV --- Net Wind lJplitt at Standbif Tactual - -,------_-=1-9.-- =19 _- - --- __ Upi(fi Ca, cl y of Standoff _ . T -allow 350 lbs Standoff Demand Ca a DCR 56.2% 1. CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ,108 NUMBER: ! JB -9223716 0 0 PREM OWNER. DESCRIPTION: ANDERSON, REBECCA ANDERSON RESIDENCE DE9GN: Jeremy Nguyen ■ —:,,So arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY '" MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape PART TO OTHERS OUTSIDE THE RECIPIENT'S LA QUINTA, CA 92253 MODULES: ORGANIZATION. EXCEPT IN CONNECTION WITHD7 THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA PACE NAME 3055 Clearvlew Way San Mateo, CA 94402_ SHEET: REV. DATE PPERMISSION OFRCITY ISOLARCITY INC. THE WRITTEN 76O 848-8920 () UPLIFT CALCULATIONS PV 4 6/22/2015 (888) T: (650) (765-24 638-1028 9) w)ww.solard cam MVERTER: ABB PVI-5000-OUTD-US-Z-A GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) LIFER AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: WMB20204OF Meter Number: lB4SR-105901 Inv 1: DC Ungrounded INV 1 — (1) ABB PVI-5000—OUTD—US—Z—A BEL: A AFCI nverter; Zigbee 5000W, 277V%240V/208V, 96.5%/96.57./96' (22) KYOCERA KU2656ZPA PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V,• Blk Cell, CA # 888104 o Backbar C-10 Underground Service Entrance INV 2 Voc: 38,3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! CUTLER—HAMMER Inverter 1 IND L 20OA/2P Disconnect 3 ' ABB Vstart = 120V PVI-5000—OUTD—US—Z—A DG MP1:1x8 (E) LOADS A JDc* _ EGC——— ————————— — ----j LI zaov r — — — — — — — — 2Dc+ • DC+ VStart = 120V • 30A/2P---- GND--------------- ---------------------- EGG DC+ — GEC G MP2: 1x7 C. I MP1,MP2: 1x7 GGND I N DG --EGC GC ------------------jCCJJDUIT rA/' t KIT 1 z Conduit / / J L 2 G 0MID TO 120/240V SINGLE PHASE C41 t UTILITY SERVICE i CI i• tits n i i I C PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, p gg ® LA V I d MITA TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF CITY GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST G & SAFETY( DEPT- ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) rFOR FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL PROVED CO STRUCTiON ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE Voc* =MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS POI (1)CUTLER—HAMMER 8 BR230 PV BACKFEED BREAKER Breaker, 30A/2P, 2 Spaces A (1)CUTLER—HAMMER 8 DG221URB /fj Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R A DATE — (1) Ground Rod; 5/8' x 8', Copper — (1) CUTLER— AMMER ,,pp DG03ONB Ground%Neutral Vit; 30A, General Duty (DG) O 1 AWG 810, THWN-2, Black W (1 )AWG 810, THWN-2, Red (1 )AWG THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 AAC (2)AWG 810, PV Wire, 60OV, Black Voc* = 345.01 VDC Isc = 9.26 ADC O (1) AWG 810, Solid Bare Copper EGC Vmp = 248 VDC Imp= 8.55 ADC LLL LLL 0 Conduit Kit; 3/j". EMT 810, - (1)AWC 86,. T}tWN-2,. Green , ,EGC/GEC - (1) Conduit, Kit;, 3/4'.EMT.......... (4 AWG 810, PV Wire, 60OV, Black Voc* = 301.88 VDC Isc = 9.26 ADC O (1) AWG j! 0, Solid Bare Copper EGC Vmp = 217 VDC Imp= 8.55 ADC (1) Conduit Kit; 3/4' EMT ........................... CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF SOLARCITY CIN JOB NUMBER \\ JB -9223716 O O PREMISE OWNER: DESCRIPTION: ANDERSON, REBECCA ANDERSON RESIDENCE DESIGN: Jeremy Nguyen •' SolarCity. Mou"„"G S' sht No SHALL IEFIT TBEISCLOOSSED N WHOLE ORT ZEP Mighty Hook w Flashing Tape 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA PAGE NAME 3055 geavies Way San Mateo, CA 94402 SHEET: REV. DATE I" ABB PVI-5000—OUTD—US—Z—A THE WRITTEN SOLARCITY PERMISSIONEOFISOLARCITY INC. 760 848-8920 (760) ) THREE LINE DIAGRAM PV 5 6/22/2015 (888) (SOL,CIIY (65-2489) 638-1028 50 638arr0iy EXISTING ELECTRICAL SERVICE ENTRANCE AND LOAD CENTER 200A 240V 10 200A MAIN BREAKER (E) METER# 1B4SR-105901 0 PROPOSED BI-DIRECTIONAL MCTER# 0 ; 30A/2P r-- -J I I •- I I I I I I I I TO 120/240V SINGLE PHASE UTILITY SERVICE ELECTRICAL ONE LINE DIAGRAM PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER HAMMER # DG221URB ` 30A, 240VAC, Non -Fusible, NEMA 3R AC --- -------------- -------- - - - - --- - -- --------------------- ---- DC I I I PV ARRAY #1 8 MODULES KYOCERA SOLAR - - - #KU2656ZPA 2120 WATT (DC) 1929 WATT (AC) 5000 WATT UTILITY INTERACTIVE INVERTER 120 TO 600 VDC TO 120 /240 VAC 10I 2 ABB # PVI-5000-OUTD-US-Z-A i PV ARRAY #2 14 MODULES KYOCERA SOLAR L - - - - - - - #KU2656ZPA 3710 WATT (DC) 3376 WATT (AC) 3 (1) AWG #10, THWN-2, Black (4 ) AWG #10, PV, Wire, 60OV, Black (1) AWG #10, THWN-2, Red vL ( 1 ) AWG #10, Solid Bare Copper EGC (1) AWG #10, THWN-2, White NEUTRAL Vmp = 240 VAC Imp = 23 AAC (1) AWG #6, THWN-2, Green EGC (2) AWG #10, PV -WIRE, 60OV, Black vL (1) AWG #10, Solid Bare Copper EGC r CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER J B- 9223716 O O PREMISE OWNER DESCRIPTION: ANDERSON, REBECCA ANDERSON RESIDENCE DESIGN: Jeremy Nguyen BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED IN WHOLE OR IN 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY w',` ; SolarCity. MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTACA 92253 Moou s ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA , PAGE NAME 3055 Clearview Way San Mateo, CA 94402 SHEET: REV: DATE INVERTER: ABB PVI-5000-OUTD-US-Z-A PERRMISSIONEQUIPMENT, THE WRITTEN SOLARCITY INC. 760 848-8920 () ONE LINE DIAGRAM PV 6 6/22/2015 (BM T.-sso aTY (7s5B-2 89) °ww638--1029 ol Ic y.com ELECTRICAL CALCULATIONS Module: 22 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 1 ABB PVI -5000-S AFCI 0.96 5000 5054.86 Inveiter 1: Vdrop = Imp) " 2 * Len th Resistance / (Vmp) Kyocera 265W 1000V 238.1 Module: Imp A Max. Length ft Wire Inverter 2: String: 8.55 70 AWG #10 at Max Ave Hi: 109 deg F Module: Inverter 3: Vdrop = 8.55 140 0.00124 Ohms / 208.94 0.71 Branch: 8.55 50 AWG #10 at Max Ave Hi: 109 deg F Vdrop = 8.55 100 0.00124 Ohms) / 248 0.51 Total voltage dropin DC conductors = 1.22 Inverter: 23 15 1 AWG #10 1 at 240V Kyocera 265W 1000V 238.1 Module: Kyocera 265W 1000V 238.1 Inverter 4: Total: 22 Modules Total Inv Pwr:I 5000 15054.86 PTC Vdrop = 23 30 0.00124 Ohms / 240 V 0.13 Combined at 240V Photovoltaic Module Electrical Specifications: Total STC:I 5830 Vdrop = Ohms) / 240 V Voc: 38.3 V deg F deg C Vmp: 31 V Record Low Temp: 14 -10 Isc: 9.26 A Max Average Hi Temp: 109 43 Total voltage drop in AC conductors = 0.13 Total voltage drop in AC and DC conductors = 0 Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisc: 5.56 1 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf TVoc Data Branch Circuit Type A 1 way wire length: N/A Voc Correction Factor: ABB PVI -5000-5 AFCI Inverter Min Vdc Input: 8 Kyocera 265W 1000V Voc= 306.4 Min Vmp at Max Temp: Max Voc at Min Temp: Vmp= 248 Inverter Max Vdc Input: Isc= 9.26 Max String Size: Imp= 8.55 1 -way wire length: (cont= 11.58 Art 690.8(A)(1) 2 strings per branch 1 strings per branch 2 7 modules per series string 8 1 modules per series string Voc= 268.1 V Voc= 306.4 V Vmp= 217 V Vmp= 248 V IsC= 18.52 A Isc= 9.26 A Imp= 17.1 A Imp= 8.55 A (cont= 28.94 A Icont= 11.58 A Art 690.8(A)(1) 130 208.94 345.01 600 13 50 1.a Conductor: AWG #10 PV Wire 2.a Conductor 1: N/A Conductor 2: N/A (cont * 1.25 = (Amps) 14.47 Conductor 1 Conductor 2 30 deg C ampacity = 40 Icont * 1.25 = (Amps) 36.171 14.47 1.b lcont= (Amps) 11.58 30 deg C ampacity = N/A N/A 2.b Icont= (Amps) 28.94 11.58 Start ampacity 40 N/A N/A Temperature derate (%=F) 0.41 Start ampacity N/A N/A Conduit fill derate (%_#) 1 Temperature derate (%=F) N/A N/A Derated ampacity 16.4 Conduit fill derate (%_#) 1.c N/A N/A Derated ampacity 2.c Term 1 Term 2 Temp table N/A N/A Icont*1.25= (Amps) 36.17 14.47 Ampacity N/A N/A C,(cont [30WINn IN S A 9 @ y o DiEp- . * 1.25 = (Amps) 14.47 Ampacity 40 1.d Icont * 1.25 = (Amps) OCP Size = 14.47 15 Inverter Type A Output ABB PVI -5000-S AFCI 1 way wire length: 15 ft 2.d OCP Size = 40 15 ti I'O C0NST C Combined Inverter Output DATE ®nI Icont = 23 A Art 690.8(A)(1) Service Voltage= 3.a Icont * 1.25 = (Amps) OCP Size =_ 28.75 Art 690.8(8)(1) Art 240.6(A) f BY Total Inverter Power- 1 way wire length= 15 (cont = # of inverters*max inverter current Art 690.8(A)(1) Icont = (Amps) 30 3.b Conductor: AWG #10 Icont * 1.25 = (Amps) ,30 deg C ampacity = 3.c `',Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity THWN-2 at 90 deg C: Table 310.16 28,75 40 23 40 0.91 1 36.4 4.a Icont*1.25 = (Amps) OCP size 28.75 Art 690.8(8)(1) Art 240.6(A) 1 301 4.b Conductor: AWG #10 (cont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 28.75 40 4.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 23 40 0.91 3.d Icont " 1.25 = (Amps) 28.75 Ampacity 35 1 36.4 4.d Icont * 1.25 = (Amps) 28.75 F_ AmDacitv 35 CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE PERRMISSIONCITY EOFISOELARCITY INC.T THE WRITTEN JOB NUMBER \\!p JB -9223716 O O PREMISE OWNER: DESCRIPTION: ANDERSON, REBECCA ANDERSON RESIDENCE 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY LA QUINTA CA 92253 , PAGE NAME 760 848-8920 () ELECTRICAL CALCULATIONS DESIGN ,leremy NguyenBENEFIT Vii„ SolarCity. MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape MODULES (22) KYOCERA # KU2656ZPA 3055 Clearview Way San Mateo, CA 94402 (888) `sot. aw (65-2489)650) 638_1 028 www.solart Ny.corn SHEET: REV. DATE PV 7 6/22/2015 INVERTER [ABB PVI-5000-OUTD-US-Z-A CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 52830 Avenida Martinez r ----------- ---------- ----- SOLAR PHOTOVOLTAIC ARRAYS)' L--------------------------J UTILITY SERVICE AC DISCONNECT INVERTER AND DC DISCONNECT PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9223716-00 CITY OF LA QUINTA BUILDING & SAFPT. APPROVED FOR CONSTRUCTION DAT CONFIDENTIAL THE INFORMATION HEREIN ALL NOT BE USED FOR THE CONTAINED SHA JOB NUMBER: JB —9223716 00 rnLax °m" ' °E.A11 n A` ANDERSON, REBECCA ANDERSON RESIDENCE "`a ' Jeremy Nguyen \ . ` OI I y. MOUNTING SYSTEM: ZEP Mighty Hook w Flashing Tape BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 52830 AVENIDA MARTINEZ 5.83 KW PV ARRAY ' " PART OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253 MODULES: ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) KYOCERA # KU2656ZPA 3055 aearview Way San Mateo, CA 94402 SHEET: DATE: PERRMISSIONCITY EOFISOLARCITY INT THE WRITTEN PAGE NAME: 760 848-8920 ( ) SITE PLAN PLACARD pREV: PV 8 6/22/2015 29 (888) (SOLO, CITY ((765-2489) 638-1028 www d Icty.can INVERTER: ABB PVI-5000—OUTD—US—Z—A WARNING Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN ` INVERTER IS UNGROUNDED BUILDING l®p A QU SAFE, D ITq Spr o ® O VEFE) E N8rRUCrl pN ABY IN THE OPEN POSITION Label Location: VOLTAGEDC • • • POINT OF (POI) ALWAYS PRESENT WHEN INTERCONNECTION Per Code: SOLAR ARE WARNING: ELECTRIC EXPOSED MODULES TO . _ • • • SHOCKUCH CEC 690.54; CEC 690.17 TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD MAY BE ENERGIZED IN THE OPEN POSITION.•SERVICE - Label Location: ' BOTH SOURCE WARNING(INV) POWER D MAINBREAKER.• HAZARDELECTRIC Per Code: MAXIMUM AC A SHOCKIF A GROUND FAULT IS INDICATED CEC 690.5(C) OPERATING NORMALLY-• . . MAXIMUM AC V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label Location: Label Location: CAUTION (D) (POI) PHOTOVOLTAIC AC (AC) (POI) • • • Per Code: (AC): AC Disconnect Per Code: . CEC 690.64.B.4DISCONNECT (C):•Conduit CEC 690.14.C.2 (CB): Combiner Box (D):Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A (AC) (POI) CAUTION (POI) (LC): Load Center OPERATING CURRENT Per Code: • - •SOURCE.Per Code: (M): Utility Meter OPERATING CEC 690.54 PHOTOVOLTAIC _CE IS CEC 705.12.D.7 (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED • .11. /. 3n Mateo, CA way •: - San Mateo, CA 99402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set S T:(650) 638 1028 F:(650) 636 1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /, O f ' (888) -CITY (765-2489) www.solarcky.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. I Designed for residential and small commercial PV installations, this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kW and 20kW. This inverter includes dual input section to process two strings with independent MPPT. The high speed and precise MPPT algorithm offers real-time power tracking and energy harvesting. Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. The transformerless operation offers high performance efficiencies of up to 97.1%. Free remote monitoring capability available with every installation. This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system. Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity „ ,t ,t for abetter world'" PUMP Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD 1-',SolarCity ®pSolar .ZS Span for concrete tile roofs Q '°MPAr'e ti W A eMPPrO UL LISTED SON zepsolar.com Next -Level PV Mounting Technology Description • PV mounting solution for concrete tile roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications t'6oiafClty ®pSOlar Next -Level PV Mounting Technology Components 1x 3x 4x Spanner Bar Part Nos. 850-1400 - 4x 580.1399 - 3x 850-1398 -1 x Splice Kit Spanner Clamp Part No. 850-1401 Part No. 850-1194 Listed to UL 2703 Listed to UL 2703 o„ Mighty Hook V2, HDG Interlock Cam Foot Part No. 850-1461 Part No. 850-1388 Part No. 850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 • Designed for pitch roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 - • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" a • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 850-0113, 850-1421, Part No. 850-1448 ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1730-001 Rev A Date last exported: April 20, 2015 2:14 PM J KU -60 1000V Z Series KU265-6ZPA CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN - UV -stabilized, lack zed „St,I(lpnt~d by majo,rlaluminum mountinQ.structure manbfact,,,ur,ers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module - First module manufacturer in the world to pass long- term sequential testing performed by TOV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 Q GOMPAT,6 ` C UL US - G pZOMP011\ ELECTRICAL SPECIFICATIONS KU -60 1000V Series MODULE CHARACTERISTICS Cells per module: 60 (6 x 10) Dimensions: length/width height 65.43ini38.98ini 1.57in (1662mm/990mm/40mm) Weight: 45.2lbs (20.5kg) P 265 W Vmp 31.0 V I 8.55 A V. 38.3 V I 9.26 A PtOle,me +5/-0 % , TNS 45 °C P 191 W V 2 9 V Imo 6.85 A V 35.1 V I 7.49 A - -- PTC 238.1 --- ----- - W 1"tflfiW3 D. I- iffi Pin— -0.45 Vmo -0.48 %/°C ImP 0.02 %J °C Vec -0.36 %J°C Ir 0.06 Operating Temp -40 to +90 °C 71Series Fuse Rating f- 15A 111 4 Maximum DC System Voltage (UL) _ — 1000V Hailstone Impact in (25mm) @ 51 mp (23m/s) 'Subject to simulator measurement uncertainty of +l- 3%. KYOCERA reserves the right to modify these specifications without notice. WARNING- Read the instruction manual i its entirely prior to handling,, installing & operat- ing Kyocera Solar modules. 090215 KU -60 1000V Series MODULE CHARACTERISTICS Cells per module: 60 (6 x 10) Dimensions: length/width height 65.43ini38.98ini 1.57in (1662mm/990mm/40mm) Weight: 45.2lbs (20.5kg) PACKAGING SPECIFICATIONS Modules per pallet 20 Pallets per 53' container. 36 Pallet box dimensions: length/width height 66ini40ini43in (1675mmi1005mmi1055mm) Pallet box weight: 1015lbs (460kg) Graundine Hole Slatted Nountim Hale 0.16- tmw 0.35'.0.47- t9—law FRAME CROSS SECTION DIAGRAM OnaO LM/SHORT SIDE HIGH EFFICIENCY MULTIGRY•STAL PHOTOVOLTAIC MODULE SOLAR by KYOCERA , KYOGERA Solar, Inc. 800 2.2+3 9580 800 52+3 2829 fa www.kyocerasolar.com OUR VALUED PARTNER DI 2 6.89 [175] ® w 6.81 [173] U 5.73 (145) c I 6.36 [162] 1 .34 (9] r C~ O N ® n 0 O N N ON B N ®.36 [111] I 0 1.01 [26] ' A UT 150 CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT QUANTITY 2 QUANTITY 4 .27 [6.8] DIA. N B ON B ®.36 [111] I 1.01 [26] ' M TANGENTIAL KNOCKOUTS FOR O QUANTITY 1 N { ® 60 1. METRIC DIMENSIONS (IN MILLIMETERS) 01 ARE SHOWN IN BRACKETS. N KNOCKOUT LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM O - QUANTITY 1 .82 146 .82 (46 N NEUTRAL #4-#14 COPPER OR ALUMINUM 6.10 [155] Wm oci OFF ® ® ® O N PA. BER. O n 30 AMP TYPE 3R GENERAL DUTY n n xi M a c 95-1445 11 8;,l 2 1 O N 150 CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT QUANTITY 2 QUANTITY 4 .27 [6.8] DIA. J v1 a2.46 62 3 MOUNTING HOLES N 3.75 [95] N 'p [ ] .88 (221 N B m m M 4.75 (121] B ®.36 [111] 1.01 [26] ' TANGENTIAL KNOCKOUTS FOR 1/2, 3/4, 1 CONDUIT QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. 281 (5.5] DIA. 2. WIRE RANGE OF LUGS IS AS FOLLOWS KNOCKOUT LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM - QUANTITY 1 .82 146 .82 (46 N NEUTRAL #4-#14 COPPER OR ALUMINUM 6.10 [155] Wm A A E Mo ar am oaBPOBmnB WARREN SPE 8/19/98 CUTLER—HAMMERPRTSBURGH PA. BER. PROHASKA 8%18/98 nnr DIMENSION SHEET IL 30 AMP TYPE 3R GENERAL DUTY ss=laas wc e ss7aoca 1=z a c 95-1445 11 8;,l 2 1 J Switching Devices 8.1 Safety Switches DG321NRB 120/240 Vac General -Duty, Fusible, Single -Throw, continued UG326NGK Q Maximum Horsepower Ratings0 NEMA1 NEMA 3R Ampere Fuse Type Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number rn Cartridge Type—Three-Pole, Three -Wire (Three Blades, Three Fuses) -240 Vac Catalog Number Catalog Number 30 — — — — — O C I 30 2 3 — — j o/ OG221UGB0 OG221URB0 60 3 10 — — OG222UGBt•r OG222UHB tit q q 100 — 15 — — OG223UGB0 OG223UHB0 400 H — — 50-125 — OG325FGKO0 OG325FRK00 600 H — — 75-200 — OG326FGK00 DG3261`111(00 Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac bbb 30 H z " 100 H T 200 H On H 1-12-3 3-7-1/2 — DG321NGB OG321NRO 3-10 7-1/2-15 — DG322NGB OG322NRB 7.12-15 15-30 — DG323NGS OG323NRB 15 25-60 — OG324NGK OG324NRK — 50-125 — OG325NGK DG325NRK 600 H — — 75-200 — UG326NGK OG326NRK UG322URB 120/240 Vac General -Duty, Non -Fusible, Single -Throw Maximum Horsepower Ratings NEMA1 NEMA3R Ampere Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof System Hating 120V 240V 240V 250V Catalog Number Catalog Number Two-Pole, Two -Wire (Two Blades) -240 Vac No I 30 2 3 — — j o/ OG221UGB0 OG221URB0 60 3 10 — — OG222UGBt•r OG222UHB tit q q 100 — 15 — — OG223UGB0 OG223UHB0 200 — — — — 00 Three -Pole, Three -Wire (Three Blades) -240 Vac dbd 30 2 111 600 3 200 — 3 7-12 — UG321UGB O OG321URB 0 10 15 — DG322UGS O OG322URB O 15 30 — DG323UGB O DG323URB O 15 60 — OG324UGKO DG324URKO 400 — — 125 — OG325UGK(D OG325URK0 600 — — 200 — OG326UGKO OG326URK0 Notes O Maximum hp ratings apply only when dual element time delay fuses are used. O Use four -wire catalog numbers below. O Solid neutral bars are not included. Order separately from table on Page 15. aWARNING! Switch is not approved for service entrance unless a neutral kit is installed. r^> Use three -wire catalog numbers below. O Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory on 200-600A general -duty switches. Catalog Numbers: 200A = 70.7759-11, 400A = 70.8063-8.600A = 70-8064.8. Volume 2—Commercial Distribution CA08100003E—February 2011 www.eaton.com 27 E.;T•ff i LVPJ7l19 BI1i1/1ESS iva/la>titaa- , 30AAnDG221URB Ueneral Duty Safety Switch .1hterru or ase uridad servicio li ero 2 Pole Non -Fusible series: ON: Polos sin fusibles series: B cant.: s' "M 1M U.E.A. Te 3R Rainproof KECHOENEU.A. DNI 09I18/201E 'pe Tipo 3R a prueba de LI L 7 $2113 12023 2 N 3.75 [95] N B m J 3 2 1 u o :o__ 0 N D 0 O 6.89 [175] N 3.75 [95] N B m J ml 3 2 1 o :o__ 0 D O 6.89 [175] 6.81 [173] 5.73 [145] 6.36 [162] 1 .34 [9] R M ON I O N 0 n N O C u e o u o m OFF 0 ® ® ® O CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT n n C QUANTITY 2 QUANTITY 4 _ va Ni 0 N 276.8 DIA. a N is 2.46 [62] 3 M UN ING HOLES [22] N N m M 4.75 (121) .88 B 1.01 [26] TANGENTIAL KNOCKOUTS FOR 1/2, 3/4,, 1 CONDUIT QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. .281 (5.5] DIA. 2. WIRE RANGE OF LUGS IS AS FOLLOWS KNOCKOUT LINE AND LOAD LUGS #6—#14 COPPER OR ALUMINUM QUANTITY 1 ,g2 [46 .82 [46 r N NEUTRAL #4—#14 COPPER OR ALUMINUM u n 6.10 [155] m A Ixe moraxrc a<umx oo .s WARREN SIPE 8719'/98 CUTLER -HAMMER ,E aiONW RaY N,= away a is B ,T•N O aa PRTSBURGH PA im ro ec asaawcm usm. m arse® rxasr wn na: nm- R. PROHASKA 8%I9/99 DIMENSION SHEET WaY R)F WNKN rt 6 i1M1611FA nan: 30 AMP TYPE 3R GENERAL DUTY 95-15-1445.DwG o SS7 DGCI iW a- SS74DGC1 1-2 - I a c --95-1445 1 II of I 3 2 1 ml Mr. ZepSolar Datasheet: ZS Tile ZS Tile'" offers the fastest and least expensive way to install PV arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove frame specification. Utilizing quarter -turn, rock -in, and drop-in con- nections, ZS tile eliminates the need for rails and separate grounding hardware while offering a superior aesthetic approach. Key System Benefits Dramatically reduces installation time Eliminated mounting rails and clip hardware Eliminates separate grounding hardware Rapid, top -accessible precision array leveling Ultra -reliable hyper -bonded grounding matrix Ultra-low parts count Enhanced aesthetics Key Technical Features Low system weight Easily enables additional support at array edges for high wind applications Interlock ETL listed to UL 1703 as ground bond means Ground Zep UL and ETL listed to UL 467 as grounding and bonding device Interlock, Leveling Foot, and Ground Zep listed to UL 2703 as PV bonding device Zep euntpaliule'" ZS Tile mounting hardware is designed for use with Zep Compatible'" PV modules from leading PV module Manufacturers. Visit zepsolar.com for a current list of Zep Compatible'" PV modules. Our Other Product Families ONPgrrB( e ZS Aero U U for low -slope & flat roofs .ZS Comp - for composition shingle roofs ZS Seam - for standing seam metal roofs ZS Span - for rail -based applications OZS Trap - for trapezoidal metal roofs OZS Wave - for corrugated roofs &STED eoMP C Page 1 of 2 Datasheet: ZS Tile Components Interlock The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. Leveling Foot [31.8mm1 F—} 130.7mm1 J_~t 1.25in „ I Izlin ® Is7.zmm[ [39Amm] 1, O225iSSin [a 1.2mm3 — 3.20in IJ (101.6mm3 F a.00in The Leveling Foot provides a means of attachment between the Pv array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (1.25' throw). Array Skirt J The Array skirt facilitates easy front -row installation while providing a clean took at the front of the PV array. Ground Zep The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket AC/DC Cable Clip Replacement Tile t The Universal Box Bracketallows rapid attachment of Clips into Zep Groove for ultra -fast and easy The Replacement Tile provides a means offlashed electrical boxes to the moduleframe. management of PV wiring and micro -Inverter cables. attachment for ZS Tile installations. Array Skirt Cap Set Tools The Array Skirt Cap Set provides an aesthetic cover for Zep Tool:4 functions. I tool; Fiat Toot: For inter -module the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. This doatmnt does at create any eapress+ananly by len Solar an about its products or seaines.lep Solar: ale atmmnb Isronlalned In the widen produnearanb to each Visit xpsohr.cors lot more intmmadon about our products and company. product. The eldase, doamatatia shipped afth Eep Solars products anstimtes the sale spedlkations retested to in the product warranty. Theastonrer is sohh respondble for eedhhg the suitability of lep5olers godrops for each use. Sperifcalloa are subject to charge without notice Upright o 7010-2012 Zen Sohr.Inc US Paten 01.5"1,, U.S. Patent 0,109,040. US8half Patents Pending. Last Update: Frbtary25.20133:11 PM Page 2 of 2