BRES2015-027278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
`mow 4 4 Q"
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BRES2015-0272
Property Address:
53700 AVENIDA MARTINEZ
APN:
774132011
Application Description:
COVE / FREDERICK / REMODEL AFTER FIRE DAMAGE
Property Zoning:
Llc. No.: 710901
Application Valuation:
$40,000.00
Applicant:
PULIDO CLEANING & RESTORATION
PMB 427
27475 YNEZ ROAD
TEMECULA, CA 92591
LICENSED CONTRACTORS DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: IIB__ License No.: 710901
Date: Contractor
OWNER -BUILDER RATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. .(Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves .
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
11111111111111111111
26
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/6/2015
Owner:
FREDERICK ROQUEMORE
56700 AVENIDA MARTINEZ
LA QUINTA, CA 92253
Contractor:
PULIDO CLEANING & RESTORATION'
PMB 427 s u Q L-�
27475 YNEZ ROAD
TEMECULA, CA 92591
(951)296-9090.
Llc. No.: 710901
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the -work for which this permit is issued.
ALT have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with th e1pvisions.
D'Date: Applica
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBIECTAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
aboveim;fiopdroperty for inspection purposes. - -
Date: Signature (Applicant or Agent)
I
'.'EhL:!saWtxii^F3+.;rph-"as2"4,,�i�"'k i.;zi�X."a's;�ya
�;:_..>a�-n�T rYi:'??-:aya.�'kY,i*:ON,�� �,��
r *DESCRIPTION � ° $, W �.: �U � � ��c
� - �-.,!'ACCOUNT";!-
�v 4 - £ ,a O W�QTY� tr .. AMOUNT: � PAID PAIU DATE?
';�A"x•,.X..,:: i..,sis9i.:Si:t.;�'Cr �:... h.f., �4tA'f' S`� b 150..aY.XxoirXia< Z�'`,fr'x':S.::kf
HOURLY PLAN CHECK' -YES. 101-0000-42600
1.5 . $105.00 $0.00 .
,
�
- iamy
.:�cZDmi'T�z.ra'��,'.r.A�.f�,
PAa'ID.F
Y:.�
- �?. r?ati Sii,af :'r '-M .
REC
EIPT#.s� CFECK#�
�T, f,.3..a:,;" - a'�:`4E$:?{^.'"ic�,.r.'. _.,iraa$.�`�7.Sf.e'.,.,';.✓>''P3�ef ,'�3'��`, �YSS^
xD.� r. . xx'ay;a d:B'a
iY<^a
BxYv:uEt;:
:JrRnrsm*:�
': r✓ "* h ; 6 l4 �,;: sY;< ;2.5:;� - : »z� a x.' ..z.X:cr ms • -.:.. " f . ';;�;.k'��a.`+ti.^w;4fF S 3b:'�yb�: %4;a-
ACCOUNT
=`kF";,• d .u,
PAIDPAIDDATEs;
-�' sDESCRIRTION :
i':r_x�.�i:,
AMOUNT`
d+'t?i`.x"5: x�2€wF'tt t'kEW .r4XaGi:.:3
HOURLY PLAN CHECK - YES 101-0000-42600
1
'$70:00 $0:00
`3at wm,sa r,>
.a.( `C".�' -''
aX t� R PAID BYE X��a �� � 1 WET
Sf"ate
:,=R,.s �Qu.. F
§' "i ? "i"
RECE P # CHECK # � CLTD BYE
e
x
+
��e. §.�
Tota[ Paid for BLDG,CITY STAFF - PER HOUR: • ` $175.00 `. $0.00
':. L.b'4a`f'
-.P.i,.DESCRIPTION',
ti DESCRIPTION ,g
:bS.
>:.
AMOl1NTIsm
qA $
111,1
PA��
a.xF.:eriY"�'"a.q
AIU,YDATE
aH .. ,xACCOUNT.QN
x �>
:
BSAS SB1473 FEE
.101-0000-20306
0
,:$2.00
$0.00
;r
, PAID BY
?:+t`.3
Y
Y�
RECEIPT #
S:.i$.L•?�YfE:rA'la9.s.a
A
CHECK # a
CLTD BY
> y� �.,,r�.
./n -yo-:#;, ,k- i.YntM :1e'4,x:'. 3'e;>~>.4.
�� �METIiOD�
_.s4. .rix .bn.R3ie:.R:eiR:CvF.-.xw_ Mr3}.%",k:�t._e:.t?aG•T�^..--3r+_�Y:
'Df. F�'e xy.si€i.l
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:' $2.00, $0.00
Igi'4;#+`-a`+ y ".
`DESCRIPTIONF: `�f�
ng, _ _it'->3a't`i-a,it-�ix"f-;:'n'�,�1'Fx.r,}f
ACCOUNT
,,.,,.k ..-yr.,,s�-^�x.<
r f�
z_,r €,,zi S';:
k
",� �.s-.-.-'!„�'n4 Ss'[t .. E". h':a g's
s. i
QTY�AMOUNTi'
'..'
§•3.r:%S
s.
=PAID a
PAID DATE
REMODEL, EA ADDITIONAL 500 SF w
101-0000-42400
=0
$65.25
$0.00
an .cr. ,.. 52'. .. T
t raPAID BY �i
,si'r "' ^�¢ d�+yzx,:;,xa.;'�-4 �T.� Y:S'+y,�`fra
',
RECEIPT#.-_
;�.xt�'�,.i... Mf
CHECK#�
'8 ;r.,Are r'.s�i •,ter ,..'Xn
BTy,
pE
v,d.r ,^._...-_t:::x ..n.s:`,±';.w.�;..8`��sl
S,.METHOD;
-f'x', €: £;Vb'"_, F,�.vxi /'''*;w5's�..,.0
-�',d::;�.:. #.'�':
€.?ia:�:w:€;�'. >E.ava4
�.tCT
. ��. X �� Irv' .7%k ,
�D
DESCRIPTION
i F
F £6.� el hxJ�ev3 CRT ! � fd Kfiw��
ACCOUNTAMOUNT
d5": :;.FS4-�
* f.Sa: k4N,h:Lx':i .4'::.fz'^�g� , %
�'
:?..3
?
DR,
g��a_s.�:
xs<.�aLQT1(
k
:�
.PAID 6�.3 y, 1a
7i„n . 3 5_.is_."s �6 a2g '."xG2 E..#.b
�P,AID
.n- _ i'.'£�'._.,,-,R f.,Y..x
REMODEL, EA.ADDITIONAL 500 SF PC
101-0000-42600
0; , $52:20
$0.00
PAID BY
.� . "i FiYi'Y�v"
METIiOU,
Y ➢q; ,a.ai. x.o-.ii-.;:.
�� RECEIPT,,4#
�'
HECK #CLTD
BY
_.. ;F
... . , .. ... '. _ a,<X>- :,:;:_.x - __..n .. :_.aae_:.
h
�zai'+.� ,»Sc imm S, aa..�.',.n
�S z. £_.-'v_F:n...d..ra1's`2
IsY_ a.nF'�` £
DESCRIPTIONS
aFY.".:a. "GaCa;,F�£atf�
ACCOUNT
,'P?'4.."f,,s,�'-`':,.+'x,a"`'ai:l�f
TYuAMOUNT
„ak`�S� n. S'
PAI_
iX
P
_.:
�:�
t _...< .Y� `
Qt,;
r
REMODEL, FIRST 100 SF -
101-0000-42400
0 . , $49.31
$0.00 .
X .°s,: A;. f'Y, _ s ,£ ^`66'
PA BY
,
i
'
`� METHOD
"`�`:f D, :Y"i.,s ,6•$ i ''
CHECK #�
'x i"''�..a.F ,,>.
BY;
k,
- .•n._. .,t-;�',,.,'if-"$+I :d k`tt3TF, RM
A x q �RECEIPT#a
-; €> uz.,-<aw.:a�?I" `�z° ,4<„.S.ra .N.x 1l. ad�s,Y.Ott 9k_.,ro
!c 'xsa' A §.,s.-isRcw`' i.i.-
,CLTD
,.sN .11a:9:t`$!r_ .Ei-,e: ...,iwr
k x A >x irACCOUNTe.'lY
DESCRIPTION
a? F " t 8}> x=i3- F4 ::'
ss D
i :,F,1' 4`? J'8 #S
j "wk
aa" >qi �: 'Dz
=r3.
PCi1D DATE
, igN cy
>" f
CZ�w
AMOUNT���RAIDg
REMODEL, FIRST 500.SF PC
: 101-0000-426300 `
0
$134.88
$0:00
�"�
fr "
q-. .. vk !°k -^f 3�:Y .m4'
`CHECK #,Y
BYE
:>RECEIPT�#
" ,a,.,: €
MWM V,' =,
CLTD
Total Paid for'REMODEL. - $301:64 $0.00
DESCRIPTION,
.T3'ay' ':.Z�'s'�"`
�N��QTY
:..
14d`''- r•,5}' ,*
"W:r °,h `".r4q
1hi ''""i^'` -F€ 'i" "
ATE
,;?�ACCOUT
...u.D_d
�PAID:
?PAIDDANOUV
RE -}}ROOF - FIRST 2,000 SF
101-0000-42404
0
; ' $49.31
$0.00'
'A.:.,.�. • }
iary
:. A_ kL ;
RECEIPT
:
HECK,
r
i i! TD1.FlcBY
. , _ .h , a .:. _ .�. 9.a". .-.fSZ .X.!P_ .I:..� v:+SY_e.. .-T"
:mDB
_yttib<
kt,
i:.4" !8k i 4.
DESCRIPTTION
�i.SGw,,`�Y"'S. Y'„R Z`. "Y
Y°y+ +: � C TEI," t'.s ?.
ACCOUNT �?
'�P"&r3`K+.N'".".1-.e'.e
zQTYa�AMOUNT�af
'E'• X 'S -i 'KS
.+ 'yam
�'.m,.. 3F"v�"yr .'Rk':r,'3fu
PAID
t . YO• 3 .z=F-
PAID DATE
tie, w ...; ' ,:.xa ...
�E+��..: ":
�aHRIWR
-
��__ :».,.
RE -ROOF -FIRST 2,000 SF PC.
101-0000-42600 '
0
$98.62
$0.00
'; na ?'
"' , �.`'. PAID BY=' a g« f
`a,'r::< '"
METFIOD
t:t-
a .t
t. ," R t'
H
C ECKa#
�LTDBY 7
z a� <,.y
�z
�'sI:.<::� ', �a:r,
..RECEIPT.#
:-_ F: t: r
r F
Total Paid for RE -ROOF: $147.93 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID. . ,
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$5.20
$0.00
PAID BY
METHOD-
RECEIPT #
CHECK #.
CLTD BY
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.20 $0.00
DESCRIPTION
ACCOUNT
QTY"
AMOUNT
PAID
PAID DATE
STUCCO APPLICATION, FIRST 500 SF
101-0000-42404
0
$24.66
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY .
' AMOUNT
PAID
PAID DATE
STUCCO APPLICATION, FIRST 500 SF PC
101-0000-42600
0
$73.97
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for STUCCO APPLICATION: $98.63 $0.00
TOTALS:00
Description: COVE / FREDERICK / REMODEL AFTER FIRE DAMAGE
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED
Applied: 7/21/2015 SKH
Approved: 10/6/2015 SKH
Parcel No: 774132011 Site Address: 53700 AVENIDA MARTINEZ LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 243 Lot: 14
Issued:
UNIT 23
CHRONOLOGY TYPE
Lot Scl Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $40,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
JIM JOHNSON
Details: REPLACEMENT OF DAMAGED ROOF JOIST, REPLACE STUCCO & WINDOWS ON SOUTH SIDE, REPLACE CEILING INSULATION AND
PARTIAL WALL. NO ELEC. OR MECH. INCLUDED IN THIS PERMIT
Printed: Tuesday, October 06, 2015 1:45:21 PM 1 of 4 CR
SYS7Eti1S
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
.NOTES
NOTE
JIM JOHNSON
8/5/2015
8/11/2015
PLAN CHECK COMMENTS
FROM CONSULTANT
JIM JOHNSON
8/7/2015
8/7/2015
RECEIVED
PLAN CHECK PICKED UP
PHILIP JUAREZ
8/11/2015
8/11/2015
JASON UNMACHT 951-453-0687 CAME TO COUNTER PICKED
UP CORRECTIONS. SPOKE WITH JJ AT COUNTER.
PLAN CHECK SENT TO
STEPHANIE KHATAMI
7/21/2015
7/21/2015
.OUTSIDE PC
PLAN CHECK SUBMITTAL
STEPHANIE KHATAMI
7/21/2015
7/21/2015
RECEIVED
TELEPHONE CALL
JIM JOHNSON
8/7/2015
8/7/2015
CALLED JASON @951453-0687 TO INFORM HIM PLANS ARE
READY FOR CORRECTIONS
CONDITIONS
Printed: Tuesday, October 06, 2015 1:45:21 PM 1 of 4 CR
SYS7Eti1S
CONDITION
DATE
DATE
DATE
CONTACT
DESCRIPTION
ACCOUNT
QTY
STATUS
REMARKS
NOTES
TYPE
METHOD
ADDED
REQUIRED
SATISFIED
READY TO ISSUE
BY
HOURLY PLAN CHECK -
NEED REVISED TITLE -24 SQ. FT. NOT CORRECT
1.5
JIM JOHNSON
10/6/2015
PENDING
CHECKLIST'
YES
COMPLETE PER JJ
CONTACTS
HOURLY PLAN CHECK -
101-0000-42600
1
$70.00
NAME TYPE
NAME
ADDRESSI
CITY STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
PULIDO CLEANING & RESTORATION
PMB 427
TEMECULA CA
92591
CONTRACTOR
PULIDO CLEANING & RESTORATION
PMB 427
TEMECULA CA
92591
$2.00
$0.00
OWNER
FREDERICK ROQUEMORE
56700 AVENIDA
LA QUINTA CA
92253
Total Paid for BUILDING STANDARDS ADMINISTRATION
$2.00 $0.00.
BSA:
REMODEL, EA
101-0000-42400
MARTINEZ
$65.25
$0.00
Printed: Tuesday, October 06, 2015 1:45:21 PM 2 of 4
CMIfflYSTEMS
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY ..
CLTD
BY
HOURLY PLAN CHECK -
101-0000-42600
1.5
$105.00
$0.00
YES
HOURLY PLAN CHECK -
101-0000-42600
1
$70.00
$0.00
YES
Total Paid for BLDG CITY STAFF - PER HOUR: $175.00 $0.00
----T--O
BSAS SB1473 FEE
101-0000-20306
$2.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$2.00 $0.00.
BSA:
REMODEL, EA
101-0000-42400
0
$65.25
$0.00
ADDITIONAL 500 SF
REMODEL, EA
101-0000-42600
0
$52.20
$0.00
ADDITIONAL 500 SF PC
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$0.00
REMODEL, FIRST 500 SF
101-0000-426000
$134.88
$0.00
PC.
Total Paid for REMODEL: $301.64 $0.00
Printed: Tuesday, October 06, 2015 1:45:21 PM 2 of 4
CMIfflYSTEMS
Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff?
SYS7Eh1S
REVIEWS
RETURNED
REVIEW TYPE
REVIEWER
SENT DATE
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
NON-STRUCTURAL -
JIM JOHNSON
7/21/2015
8/4/2015
8/5/2015
REVISIONS REQUIRED
PLANC INCOMPLETE
2'WK
BY
RE -ROOF - FIRST 2,000
101-0000-42404
0
$49.31
$0.00
KATHRYN
7/21/2015
8/4/2015
8/10/2015
REVISIONS REQUIRED
SF
SAMUELS
2ND BLDG NS (2
JIM JOHNSON
RE -ROOF - FIRST 2,000
101-0000-426000
9/8/2015
$98.62
$0.00
lincomplete.
WK)
SF PC
Total Paid for RE -ROOF: $147.93 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$5.20
$0.00
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.20 $0.00
STUCCO APPLICATION,
101-0000-42404
0
$24.66
$0.00
FIRST 500 SF
STUCCO APPLICATION,
101-0000-42600
0
$73.97.
$0.00
FIRST 500 SF PC
Total Paid for STUCCO APPLICATION: $98.63 $0.00
TOTALS:0•
INSPECTIONS
SEQID INSPECTION TYPE - INSPECTORSCHEDULED COMPLETED
.. RESULT REMARKS - ; NOTES
DATE DATE
FINAL*" BLD
Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff?
SYS7Eh1S
REVIEWS
RETURNED
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
STATUS
REMARKS
NOTES
DATE
NON-STRUCTURAL -
JIM JOHNSON
7/21/2015
8/4/2015
8/5/2015
REVISIONS REQUIRED
PLANC INCOMPLETE
2'WK
STRUCTURAL - 2 WK
KATHRYN
7/21/2015
8/4/2015
8/10/2015
REVISIONS REQUIRED
SAMUELS
2ND BLDG NS (2
JIM JOHNSON
9/1/2015
9/16/2015
9/8/2015
REVISIONS REQUIRED
lincomplete.
WK)
Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff?
SYS7Eh1S
2ND BLDG STR (2I YOUNG I 9/1/2015 I 9/16/2015 I 9/16/2015 I READY FOR APPROVAL
WK) ENGINEERING
BOND INFORMATION
Printed: Tuesday, October 06, 2015 1:45:21 PM 4 of 4 C
syszents
ATTACHMENTS
Attachment Type
CREATED
OWNER DESCRIPTION PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/5/2015
JIM JOHNSON
53-700 AVE
53-700 AVE
0
MARTINEZ.docx
MARTINEZ.docx
DOC
9/8/2015
JIM JOHNSON
53-700 AVE
53-700 AVE
0
MARTINEZ.docx
MARTINEZ l.docx
IST REVIEW.-
NEW CITY
DOC
8/10/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0272 (lst).pdf
1ST REVIEW -
DOC
8/10/2015
KATHRYN SAMUELS
STRUCTURAL
BRES 2015-0272 KS
0
(lst).doc
COMMENTS
2ND REVIEW -
NEW CITY•
DOC
9/16/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0272 (2nd).pdf
CORRECTION LIST AND
CORRECTION LIST AND
DOC
9/1/2015
STEPHANIE KHATAMI
COMMENTS 09-01-
COMMENTS 09-01-
0
15.pdf
15.pdf
Printed: Tuesday, October 06, 2015 1:45:21 PM 4 of 4 C
syszents
53700 Avenida Martinez
BRES2015-0272
Bin.#
0ty of til Qi1If1
Building 8r Safety Division
P.O. Box 1504,78-495 Cafie Tampico
La.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address
6
Owner's Name:.
A. P. Number.
Address:C2 ,
Legal Description:
City, ST, Zip:
Telephone: —ial0
Project Description:
ZSs
h
Contractor:f€: :sa
t
Address: Jc,
City, ST, Zip.-
ip:Telephone:
Telephone:i
State Lie. #:--I
y c rte;
City Lie. #•:
J
Arch., Engr., Designer:
E
Address: +Z, 03
J. 'T
City., ST, Zip: .
Telephone: C. WJ4 _
State Lic. #:
Name of Contact Person: J
Construction Type:. Occupancy:
v
Project type (circle one): New Add'n Alter Rep ' Demo
Sq. Ft: • # Stories: # Units:
Telephone # of Contact Person:
Estimated Valine of Project J40.'000
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACMG
PERMIT FEES
Plan Sets
Plan Cheek submitted.Item
Amount
Structural Calm
Truss Cates.
Reviewed, ready f correctionsti71
Called Contact Person
7
Plan Check Deposit.
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted '
Mecharilcal
Grading plan
2'! Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'i° Review; ready for correctionslissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit LSsuo' -
School Fees
to
0 0
-iai&c**4i
Total Permit Fees
Letter of Transmittal
To:
City of La Quinta Today's Date:
9-16-115
78-495 Calle Tampico City Due Date:
9-16-15
La Quinta, CA 92253 Project Address:
53700 Avenida Martinez
Attn:
Kay Plan Check #:
BRES 2015-0272
Submittal: 1st
❑
41h
®. 2nd
❑
55th
❑ 3'd
❑
Other:
We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS)
❑ Your Pickup
Includes: # Of Descriptions: Includes:
# Of ,
Descriptions:
Copies:
Copies:
®
1 Structural Plans
❑
Revised Structural Plans
®
1 Structural Calculations
❑ "
Revised Struct. Calcs
❑
Truss Calculations Floor
ElRevised
Truss
and Roof
❑
Soils Report
❑
Revised Soils Report
®
1 Structural Comment.
❑
Approved Structural Plans
List/Responses
❑
Redlined Structural Plans
❑
Approved Structural Calcs
❑
Redlined Structural Calcs
❑
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
®
2
Other: Structural Repair
Recommendation Report
Comments: Structural content is approvable. -
If you .have any questions, please call.
Time = 1 HR
This 'Material Sent for:
❑ Your Files
❑ Your Review
❑ Checking
Other: ❑
BY: Kathryn Samuels
Palm Desert Office: ® (760) 772-5107
Other: ❑
® Per Your Request
El Approval
❑ At the request of: _
0
•
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Roquemore Residence
53-700 Avenida Martinez
La Quinta , CA 92253
Project Designer:
Consulting Structural Engineers
PO Box 2783
Corona, CA 92878
(951) 674-7848
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
CITY OF LA QUINTA
Job Number:
F?t'3li_DII G & SAFETY DEPT.
! - P _
A P RO` ED
FOR CONSTFj,UCTION
Date: )H
10/6/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is,
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
u
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD C*RF-01
Project Name: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Pagel of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xm1
GENERAL INFORMATION
j
01
Project Name Roquemore Residence
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 53-700 Avenida Martinez
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 1590
15
Number of Zones 2
16
Slab Area (ft2) 1590
17
Number of Stories 1
18
Addition Cond. Floor Area 350
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 350
21
Glazing Percentage (%) 21.0%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
13.79
14.65
-0.86
-6.2%
Space Cooling
246.11
246.88
-0.77
-0.3%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
13.84
11.93
1.91
13.8%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
273.74
273.46
0.28
0.1%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD CF*RF-01
Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 2 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Cathedral Ceiling
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
— None —
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
— None —
Domestic Hot Water System Verifications:
— None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design -Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)" 326.44 326.16 0.28 0.1%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Roquemore Residence
1590
1
6
2
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
ex res
Conditioned
HVAC1
1240
9
DHW Sys 1
Repair
Conditioned
HVAC1
350
9
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
CERTI,fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD C*RF-01
Project ame: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Page 3 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall ex
ex res
R-13 Wall
0
Left
432
61
90
Existing
No
E Wall ex
ex res
R-13 Wall
90
Back
432
9
90
Existing
No
S Wall ex
ex res
R-13 Wall
180
Right
350
90
Existing
No
W Wall ex
ex res
R-13 Wall
270
Front
432
43.6
90
Existing
No
Roof 2
ex res
Default 1978 to present
1240
Existing
No
N Wall
Repair
R-13 Wall
0
Left
250
64
90
Altered
N/A
E Wall
Repair
R-13 Wall
0
Left
432
64
90
Altered
N/A
S Wall
Repair
R-13 Wall
0
Left
630
72
90
Altered
N/A
W Wall
Repair
R-13 Wall
0
Left
432
64
90
Altered
N/A
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
06
07
08
09
10
11
12
13
Name
Zone
Type
Orientatio
n
Area
(ft)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt(deg)
Roof
Reflectan
ce
Roof
Emittance
Framin
g
Factor
Status
Verified
Existing
Condifion
Roof
Repair
R-30 Roof rafter
Left
350
0
0
0
0
0.1
0.85
0.1
New
N/A
ATTIC
01
02
03
04
06
06
07
08
09
10
Radiant
Statu
Verified Existing
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Barrier
Cool Roof
s
Condition
Attic ex res
Attic Roofex res
Ventilated
3
0.1
0.85
No
No
Existi
No
ng
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE•HOD C*RF-01
Project
'PTE
Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 4 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xm1
WINDOWS
01
02
03 04
05
06 07 08 09
10 11
Name
Surface (Orientation -Azimuth)
Width(ft) Height (ft)
Multiplie
r
Area (ft) U -factor SHGC Exterior Shading
Verified
Existing
Status Condition
3x3 no damage
N Wall ex (Left -0)
- -
1
9.0 1.19 0.83 Insect Screen (default)
Existing No
5x4 no damage
N Wall ex (Left -0)
- -
1
20.0 1.19 0.83 Insect Screen (default)
Existing No
8x4 no damage
N Wall ex (Left -0)
- -
1
32.0 1.19 0.83 Insect Screen (default)
Existing No
6x6.7 no damage
E Wall ex (Back -90)
- -
1
9.0 1.19 0.83 Insect Screen (default)
Existing No
6x4 altered .48-.24
N Wall (Left -0)
- -
1
64.0 0.48 0.24 Insect Screen (default)
Altered N/A
6x4 altered .48-.24 2
E Wall (Left -0)
- -
1
64.0 0.48 0.24 Insect Screen (default)
Altered N/A
1x4 altered .48-.24
S Wall (Left -0)
- -
1
4.0 0.48 0.24 Insect Screen (default)
Altered N/A
6x4 altered .48-.24 3
S Wall (Left -0)
- -
1
64.0 0.48 0.24 Insect Screen (default)
Altered N/A
1x4 altered .48-.24 2
S Wall (Left -0)
- -
1
4.0 0.48 0.24 Insect Screen (default)
Altered N/A
6x4 altered .48-.24 4
W Wall (Left -0)
- -
1
64.0 0.48 0.24 1 Insect Screen (default)
I Altered N/A
DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U -factor
Status
Verified Existing Condition
23.5 ex
W Wall ex
23.5
0.50
Existing
No
20.1 ex
W Wall ex
20.1
0.50
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-06 12:56:35
CERTI9E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE C. C RF -01
Project ame: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Page 5 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xmi
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
120
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
Repair
350
40
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck: Wood Siding/sheathing/decking
Attic Roofex res
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
- Cavity/Frame:. R-9.1 /2x4
Default 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 aQ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
• Cavity/ Frame: R -30/2x10
• Roof Deck: Wood Siding/sheathing/decking
R-30 Roof rafter
Cathedral Ceilings
Wood Framed Ceiling
2x10 @ 16 in. O.C.
R 30
0.037
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab ex
ex res
1240
120
None
0.8
No
Existing
No
Slab -on -Grade
Repair
350
40
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Altered
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD C*RF-01
Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 6 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Multi -speed
Heating System
Cooling System
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
1590
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntdFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10
12
No
No
N/A
system
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-10-06 12:56:35
CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD C*RF-01
Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 7 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
I— —
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 1 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
I— —
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name . IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1 61 0.52459 1
PROJECT NOTES
Fire Damage Repair
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
CERTIVTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD C*RF-01
Project ame: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 8 of 8
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
10/6/2015
Address:
CEA/HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/StatePliln.m Desert, CA 92211
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
William M. Peck
Company:
Date Signed:
Consulting Structural Engineers
Address:
License:
PO Box 2783
City/State/Zip:
Phone:
Corona, CA 92878
(951) 674-7848
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35
Ah
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Roquemore Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
10/6/2015
Project Address
53-700 Avenida Martinez La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,590
Addition
350
# of Units
1
INSULATION
Construction Type
Area
Cavi (ft)Special Features Status
Roof Wood Framed Attic R11 1,240 Existing
Wall Wood Framed R 13 1,532 Existing
Door Opaque Door - no insulation 44 Existing
Slab Unheated Slab -on -Grade - no insulation 1,590 Perim = 160' Existing
Demising Wood Framed - no insulation 429 Existing
Roof Wood Framed Rafter R 30 350 New
Wall Wood Framed R 13 1,480 Altered
Demising Wood Framed R 13 350 New
FENESTRATION Total Area: 334 GlazingPercentage: 21.0 b New/Altered Average U -Factor: 0.48
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Left (N) 61.0 1.190
0.83 none none Bug Screen Existing
Rear (E) 9.0 1.190
0.83 none none Bug Screen Existing
Left (N) 264.0 0.480
0.24 none none Bug Screen Altered
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Storage Gas 50
0.66 All Pipes Ins Altered
EnemyPro 6.7 by EnemySoft User Number: 6712
RunCode: 2015-10-06T12:57:04 ID:
Pae 11 of 15
4
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may annly. Review the respective Inde sectinn fnr mnre infnrmntinn_
Building Envelope Measures:
§I10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
'
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ I50.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ I50.0(e)I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ I50.0(e)I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ I50.0(e)I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
§110.3(c)5:
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of §I10.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
4
2613 Low -Rise Residential Mandatory Measures Summary
§ I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)1 l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§I 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
settin • a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
4
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k)1 A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§I50.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§I50.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§I50.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5• and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
'
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
0
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I50.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, $130.4, $140.7 and § 141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
'130.4,
shall comply with the applicable requirements in 110.9 130.0, §130.2, 140.7 and 141.0.
§150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9, 130.0 130.2 130.4, 140.7 and 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9 130.0 130.1 130.4 140.6 and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§1 10.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10 e .
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of $110.10 b through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §I 10.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
0
44)
4x
N
r
Q
J
2
- a N
G J41)
0