Loading...
BRES2015-027278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 `mow 4 4 Q" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2015-0272 Property Address: 53700 AVENIDA MARTINEZ APN: 774132011 Application Description: COVE / FREDERICK / REMODEL AFTER FIRE DAMAGE Property Zoning: Llc. No.: 710901 Application Valuation: $40,000.00 Applicant: PULIDO CLEANING & RESTORATION PMB 427 27475 YNEZ ROAD TEMECULA, CA 92591 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: IIB__ License No.: 710901 Date: Contractor OWNER -BUILDER RATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. .(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves . thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's 11111111111111111111 26 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/6/2015 Owner: FREDERICK ROQUEMORE 56700 AVENIDA MARTINEZ LA QUINTA, CA 92253 Contractor: PULIDO CLEANING & RESTORATION' PMB 427 s u Q L-� 27475 YNEZ ROAD TEMECULA, CA 92591 (951)296-9090. Llc. No.: 710901 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the -work for which this permit is issued. ALT have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with th e1pvisions. D'Date: Applica WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBIECTAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the aboveim;fiopdroperty for inspection purposes. - - Date: Signature (Applicant or Agent) I '.'EhL:!saWtxii^F3+.;rph-"as2"4,,�i�"'k i.;zi�X."a's;�ya �;:_..>a�-n�T rYi:'??-:aya.�'kY,i*:ON,�� �,�� r *DESCRIPTION � ° $, W �.: �U � � ��c � - �-.,!'ACCOUNT";!- �v 4 - £ ,a O W�QTY� tr .. AMOUNT: � PAID PAIU DATE? ';�A"x•,.X..,:: i..,sis9i.:Si:t.;�'Cr �:... h.f., �4tA'f' S`� b 150..aY.XxoirXia< Z�'`,fr'x':S.::kf HOURLY PLAN CHECK' -YES. 101-0000-42600 1.5 . $105.00 $0.00 . , � - iamy .:�cZDmi'T�z.ra'��,'.r.A�.f�, PAa'ID.F Y:.� - �?. r?ati Sii,af :'r '-M . REC EIPT#.s� CFECK#� �T, f,.3..a:,;" - a'�:`4E$:?{^.'"ic�,.r.'. _.,iraa$.�`�7.Sf.e'.,.,';.✓>''P3�ef ,'�3'��`, �YSS^ xD.� r. . xx'ay;a d:B'a iY<^a BxYv:uEt;: :JrRnrsm*:� ': r✓ "* h ; 6 l4 �,;: sY;< ;2.5:;� - : »z� a x.' ..z.X:cr ms • -.:.. " f . ';;�;.k'��a.`+ti.^w;4fF S 3b:'�yb�: %4;a- ACCOUNT =`kF";,• d .u, PAIDPAIDDATEs; -�' sDESCRIRTION : i':r_x�.�i:, AMOUNT` d+'t?i`.x"5: x�2€wF'tt t'kEW .r4XaGi:.:3 HOURLY PLAN CHECK - YES 101-0000-42600 1 '$70:00 $0:00 `3at wm,sa r,> .a.( `C".�' -'' aX t� R PAID BYE X��a �� � 1 WET Sf"ate :,=R,.s �Qu.. F §' "i ? "i" RECE P # CHECK # � CLTD BYE e x + ��e. §.� Tota[ Paid for BLDG,CITY STAFF - PER HOUR: • ` $175.00 `. $0.00 ':. L.b'4a`f' -.P.i,.DESCRIPTION', ti DESCRIPTION ,g :bS. >:. AMOl1NTIsm qA $ 111,1 PA�� a.xF.:eriY"�'"a.q AIU,YDATE aH .. ,xACCOUNT.QN x �> : BSAS SB1473 FEE .101-0000-20306 0 ,:$2.00 $0.00 ;r , PAID BY ?:+t`.3 Y Y� RECEIPT # S:.i$.L•?�YfE:rA'la9.s.a A CHECK # a CLTD BY > y� �.,,r�. ./n -yo-:#;, ,k- i.YntM :1e'4,x:'. 3'e;>~>.4. �� �METIiOD� _.s4. .rix .bn.R3ie:.R:eiR:CvF.-.xw_ Mr3}.%",k:�t._e:.t?aG•T�^..--3r+_�Y: 'Df. F�'e xy.si€i.l Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:' $2.00, $0.00 Igi'4;#+`-a`+ y ". `DESCRIPTIONF: `�f� ng, _ _it'->3a't`i-a,it-�ix"f-;:'n'�,�1'Fx.r,}f ACCOUNT ,,.,,.k ..-yr.,,s�-^�x.< r f� z_,r €,,zi S';: k ",� �.s-.-.-'!„�'n4 Ss'[t .. E". h':a g's s. i QTY�AMOUNTi' '..' §•3.r:%S s. =PAID a PAID DATE REMODEL, EA ADDITIONAL 500 SF w 101-0000-42400 =0 $65.25 $0.00 an .cr. ,.. 52'. .. T t raPAID BY �i ,si'r "' ^�¢ d�+yzx,:;,xa.;'�-4 �T.� Y:S'+y,�`fra ', RECEIPT#.-_ ;�.xt�'�,.i... Mf CHECK#� '8 ;r.,Are r'.s�i •,ter ,..'Xn BTy, pE v,d.r ,^._...-_t:::x ..n.s:`,±';.w.�;..8`��sl S,.METHOD; -f'x', €: £;Vb'"_, F,�.vxi /'''*;w5's�..,.0 -�',d::;�.:. #.'�': €.?ia:�:w:€;�'. >E.ava4 �.tCT . ��. X �� Irv' .7%k , �D DESCRIPTION i F F £6.� el hxJ�ev3 CRT ! � fd Kfiw�� ACCOUNTAMOUNT d5": :;.FS4-� * f.Sa: k4N,h:Lx':i .4'::.fz'^�g� , % �' :?..3 ? DR, g��a_s.�: xs<.�aLQT1( k :� .PAID 6�.3 y, 1a 7i„n . 3 5_.is_."s �6 a2g '."xG2 E..#.b �P,AID .n- _ i'.'£�'._.,,-,R f.,Y..x REMODEL, EA.ADDITIONAL 500 SF PC 101-0000-42600 0; , $52:20 $0.00 PAID BY .� . "i FiYi'Y�v" METIiOU, Y ➢q; ,a.ai. x.o-.ii-.;:. �� RECEIPT,,4# �' HECK #CLTD BY _.. ;F ... . , .. ... '. _ a,<X>- :,:;:_.x - __..n .. :_.aae_:. h �zai'+.� ,»Sc imm S, aa..�.',.n �S z. £_.-'v_F:n...d..ra1's`2 IsY_ a.nF'�` £ DESCRIPTIONS aFY.".:a. "GaCa;,F�£atf� ACCOUNT ,'P?'4.."f,,s,�'-`':,.+'x,a"`'ai:l�f TYuAMOUNT „ak`�S� n. S' PAI_ iX P _.: �:� t _...< .Y� ` Qt,; r REMODEL, FIRST 100 SF - 101-0000-42400 0 . , $49.31 $0.00 . X .°s,: A;. f'Y, _ s ,£ ^`66' PA BY , i ' `� METHOD "`�`:f D, :Y"i.,s ,6•$ i '' CHECK #� 'x i"''�..a.F ,,>. BY; k, - .•n._. .,t-;�',,.,'if-"$+I :d k`tt3TF, RM A x q �RECEIPT#a -; €> uz.,-<aw.:a�?I" `�z° ,4<„.S.ra .N.x 1l. ad�s,Y.Ott 9k_.,ro !c 'xsa' A §.,s.-isRcw`' i.i.- ,CLTD ,.sN .11a:9:t`$!r_ .Ei-,e: ...,iwr k x A >x irACCOUNTe.'lY DESCRIPTION a? F " t 8}> x=i3- F4 ::' ss D i :,F,1' 4`? J'8 #S j "wk aa" >qi �: 'Dz =r3. PCi1D DATE , igN cy >" f CZ�w AMOUNT���RAIDg REMODEL, FIRST 500.SF PC : 101-0000-426300 ` 0 $134.88 $0:00 �"� fr " q-. .. vk !°k -^f 3�:Y .m4' `CHECK #,Y BYE :>RECEIPT�# " ,a,.,: € MWM V,' =, CLTD Total Paid for'REMODEL. - $301:64 $0.00 DESCRIPTION, .T3'ay' ':.Z�'s'�"` �N��QTY :.. 14d`''- r•,5}' ,* "W:r °,h `".r4q 1hi ''""i^'` -F€ 'i" " ATE ,;?�ACCOUT ...u.D_d �PAID: ?PAIDDANOUV RE -}}ROOF - FIRST 2,000 SF 101-0000-42404 0 ; ' $49.31 $0.00' 'A.:.,.�. • } iary :. A_ kL ; RECEIPT : HECK, r i i! TD1.FlcBY . , _ .h , a .:. _ .�. 9.a". .-.fSZ .X.!P_ .I:..� v:+SY_e.. .-T" :mDB _yttib< kt, i:.4" !8k i 4. DESCRIPTTION �i.SGw,,`�Y"'S. Y'„R Z`. "Y Y°y+ +: � C TEI," t'.s ?. ACCOUNT �? '�P"&r3`K+.N'".".1-.e'.e zQTYa�AMOUNT�af 'E'• X 'S -i 'KS .+ 'yam �'.m,.. 3F"v�"yr .'Rk':r,'3fu PAID t . YO• 3 .z=F- PAID DATE tie, w ...; ' ,:.xa ... �E+��..: ": �aHRIWR - ��__ :».,. RE -ROOF -FIRST 2,000 SF PC. 101-0000-42600 ' 0 $98.62 $0.00 '; na ?' "' , �.`'. PAID BY=' a g« f `a,'r::< '" METFIOD t:t- a .t t. ," R t' H C ECKa# �LTDBY 7 z a� <,.y �z �'sI:.<::� ', �a:r, ..RECEIPT.# :-_ F: t: r r F Total Paid for RE -ROOF: $147.93 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID. . , PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $5.20 $0.00 PAID BY METHOD- RECEIPT # CHECK #. CLTD BY Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.20 $0.00 DESCRIPTION ACCOUNT QTY" AMOUNT PAID PAID DATE STUCCO APPLICATION, FIRST 500 SF 101-0000-42404 0 $24.66 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY . ' AMOUNT PAID PAID DATE STUCCO APPLICATION, FIRST 500 SF PC 101-0000-42600 0 $73.97 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for STUCCO APPLICATION: $98.63 $0.00 TOTALS:00 Description: COVE / FREDERICK / REMODEL AFTER FIRE DAMAGE Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 7/21/2015 SKH Approved: 10/6/2015 SKH Parcel No: 774132011 Site Address: 53700 AVENIDA MARTINEZ LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 243 Lot: 14 Issued: UNIT 23 CHRONOLOGY TYPE Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $40,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 JIM JOHNSON Details: REPLACEMENT OF DAMAGED ROOF JOIST, REPLACE STUCCO & WINDOWS ON SOUTH SIDE, REPLACE CEILING INSULATION AND PARTIAL WALL. NO ELEC. OR MECH. INCLUDED IN THIS PERMIT Printed: Tuesday, October 06, 2015 1:45:21 PM 1 of 4 CR SYS7Eti1S ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE .NOTES NOTE JIM JOHNSON 8/5/2015 8/11/2015 PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 8/7/2015 8/7/2015 RECEIVED PLAN CHECK PICKED UP PHILIP JUAREZ 8/11/2015 8/11/2015 JASON UNMACHT 951-453-0687 CAME TO COUNTER PICKED UP CORRECTIONS. SPOKE WITH JJ AT COUNTER. PLAN CHECK SENT TO STEPHANIE KHATAMI 7/21/2015 7/21/2015 .OUTSIDE PC PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 7/21/2015 7/21/2015 RECEIVED TELEPHONE CALL JIM JOHNSON 8/7/2015 8/7/2015 CALLED JASON @951453-0687 TO INFORM HIM PLANS ARE READY FOR CORRECTIONS CONDITIONS Printed: Tuesday, October 06, 2015 1:45:21 PM 1 of 4 CR SYS7Eti1S CONDITION DATE DATE DATE CONTACT DESCRIPTION ACCOUNT QTY STATUS REMARKS NOTES TYPE METHOD ADDED REQUIRED SATISFIED READY TO ISSUE BY HOURLY PLAN CHECK - NEED REVISED TITLE -24 SQ. FT. NOT CORRECT 1.5 JIM JOHNSON 10/6/2015 PENDING CHECKLIST' YES COMPLETE PER JJ CONTACTS HOURLY PLAN CHECK - 101-0000-42600 1 $70.00 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT PULIDO CLEANING & RESTORATION PMB 427 TEMECULA CA 92591 CONTRACTOR PULIDO CLEANING & RESTORATION PMB 427 TEMECULA CA 92591 $2.00 $0.00 OWNER FREDERICK ROQUEMORE 56700 AVENIDA LA QUINTA CA 92253 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00. BSA: REMODEL, EA 101-0000-42400 MARTINEZ $65.25 $0.00 Printed: Tuesday, October 06, 2015 1:45:21 PM 2 of 4 CMIfflYSTEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY .. CLTD BY HOURLY PLAN CHECK - 101-0000-42600 1.5 $105.00 $0.00 YES HOURLY PLAN CHECK - 101-0000-42600 1 $70.00 $0.00 YES Total Paid for BLDG CITY STAFF - PER HOUR: $175.00 $0.00 ----T--O BSAS SB1473 FEE 101-0000-20306 $2.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00. BSA: REMODEL, EA 101-0000-42400 0 $65.25 $0.00 ADDITIONAL 500 SF REMODEL, EA 101-0000-42600 0 $52.20 $0.00 ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 REMODEL, FIRST 500 SF 101-0000-426000 $134.88 $0.00 PC. Total Paid for REMODEL: $301.64 $0.00 Printed: Tuesday, October 06, 2015 1:45:21 PM 2 of 4 CMIfflYSTEMS Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff? SYS7Eh1S REVIEWS RETURNED REVIEW TYPE REVIEWER SENT DATE CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY NON-STRUCTURAL - JIM JOHNSON 7/21/2015 8/4/2015 8/5/2015 REVISIONS REQUIRED PLANC INCOMPLETE 2'WK BY RE -ROOF - FIRST 2,000 101-0000-42404 0 $49.31 $0.00 KATHRYN 7/21/2015 8/4/2015 8/10/2015 REVISIONS REQUIRED SF SAMUELS 2ND BLDG NS (2 JIM JOHNSON RE -ROOF - FIRST 2,000 101-0000-426000 9/8/2015 $98.62 $0.00 lincomplete. WK) SF PC Total Paid for RE -ROOF: $147.93 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $5.20 $0.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.20 $0.00 STUCCO APPLICATION, 101-0000-42404 0 $24.66 $0.00 FIRST 500 SF STUCCO APPLICATION, 101-0000-42600 0 $73.97. $0.00 FIRST 500 SF PC Total Paid for STUCCO APPLICATION: $98.63 $0.00 TOTALS:0• INSPECTIONS SEQID INSPECTION TYPE - INSPECTORSCHEDULED COMPLETED .. RESULT REMARKS - ; NOTES DATE DATE FINAL*" BLD Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff? SYS7Eh1S REVIEWS RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE NON-STRUCTURAL - JIM JOHNSON 7/21/2015 8/4/2015 8/5/2015 REVISIONS REQUIRED PLANC INCOMPLETE 2'WK STRUCTURAL - 2 WK KATHRYN 7/21/2015 8/4/2015 8/10/2015 REVISIONS REQUIRED SAMUELS 2ND BLDG NS (2 JIM JOHNSON 9/1/2015 9/16/2015 9/8/2015 REVISIONS REQUIRED lincomplete. WK) Printed: Tuesday, October 06, 2015 1:45:21 PM 3 of 4 Cff? SYS7Eh1S 2ND BLDG STR (2I YOUNG I 9/1/2015 I 9/16/2015 I 9/16/2015 I READY FOR APPROVAL WK) ENGINEERING BOND INFORMATION Printed: Tuesday, October 06, 2015 1:45:21 PM 4 of 4 C syszents ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/5/2015 JIM JOHNSON 53-700 AVE 53-700 AVE 0 MARTINEZ.docx MARTINEZ.docx DOC 9/8/2015 JIM JOHNSON 53-700 AVE 53-700 AVE 0 MARTINEZ.docx MARTINEZ l.docx IST REVIEW.- NEW CITY DOC 8/10/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0272 (lst).pdf 1ST REVIEW - DOC 8/10/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0272 KS 0 (lst).doc COMMENTS 2ND REVIEW - NEW CITY• DOC 9/16/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0272 (2nd).pdf CORRECTION LIST AND CORRECTION LIST AND DOC 9/1/2015 STEPHANIE KHATAMI COMMENTS 09-01- COMMENTS 09-01- 0 15.pdf 15.pdf Printed: Tuesday, October 06, 2015 1:45:21 PM 4 of 4 C syszents 53700 Avenida Martinez BRES2015-0272 Bin.# 0ty of til Qi1If1 Building 8r Safety Division P.O. Box 1504,78-495 Cafie Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address 6 Owner's Name:. A. P. Number. Address:C2 , Legal Description: City, ST, Zip: Telephone: —ial0 Project Description: ZSs h Contractor:f€: :sa t Address: Jc, City, ST, Zip.- ip:Telephone: Telephone:i State Lie. #:--I y c rte; City Lie. #•: J Arch., Engr., Designer: E Address: +Z, 03 J. 'T City., ST, Zip: . Telephone: C. WJ4 _ State Lic. #: Name of Contact Person: J Construction Type:. Occupancy: v Project type (circle one): New Add'n Alter Rep ' Demo Sq. Ft: • # Stories: # Units: Telephone # of Contact Person: Estimated Valine of Project J40.'000 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACMG PERMIT FEES Plan Sets Plan Cheek submitted.Item Amount Structural Calm Truss Cates. Reviewed, ready f correctionsti71 Called Contact Person 7 Plan Check Deposit. Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted ' Mecharilcal Grading plan 2'! Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'i° Review; ready for correctionslissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit LSsuo' - School Fees to 0 0 -iai&c**4i Total Permit Fees Letter of Transmittal To: City of La Quinta Today's Date: 9-16-115 78-495 Calle Tampico City Due Date: 9-16-15 La Quinta, CA 92253 Project Address: 53700 Avenida Martinez Attn: Kay Plan Check #: BRES 2015-0272 Submittal: 1st ❑ 41h ®. 2nd ❑ 55th ❑ 3'd ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of , Descriptions: Copies: Copies: ® 1 Structural Plans ❑ Revised Structural Plans ® 1 Structural Calculations ❑ " Revised Struct. Calcs ❑ Truss Calculations Floor ElRevised Truss and Roof ❑ Soils Report ❑ Revised Soils Report ® 1 Structural Comment. ❑ Approved Structural Plans List/Responses ❑ Redlined Structural Plans ❑ Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ® 2 Other: Structural Repair Recommendation Report Comments: Structural content is approvable. - If you .have any questions, please call. Time = 1 HR This 'Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ BY: Kathryn Samuels Palm Desert Office: ® (760) 772-5107 Other: ❑ ® Per Your Request El Approval ❑ At the request of: _ 0 • BUILDING ENERGY ANALYSIS REPORT PROJECT: Roquemore Residence 53-700 Avenida Martinez La Quinta , CA 92253 Project Designer: Consulting Structural Engineers PO Box 2783 Corona, CA 92878 (951) 674-7848 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 CITY OF LA QUINTA Job Number: F?t'3li_DII G & SAFETY DEPT. ! - P _ A P RO` ED FOR CONSTFj,UCTION Date: )H 10/6/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is, authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. u CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD C*RF-01 Project Name: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Pagel of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xm1 GENERAL INFORMATION j 01 Project Name Roquemore Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 53-700 Avenida Martinez Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1590 15 Number of Zones 2 16 Slab Area (ft2) 1590 17 Number of Stories 1 18 Addition Cond. Floor Area 350 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 350 21 Glazing Percentage (%) 21.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 13.79 14.65 -0.86 -6.2% Space Cooling 246.11 246.88 -0.77 -0.3% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 13.84 11.93 1.91 13.8% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 273.74 273.46 0.28 0.1% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD CF*RF-01 Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Cathedral Ceiling HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: — None — Cooling System Verifications: — None — HVAC Distribution System Verifications: — None — Domestic Hot Water System Verifications: — None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design -Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)" 326.44 326.16 0.28 0.1% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Roquemore Residence 1590 1 6 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 ex res Conditioned HVAC1 1240 9 DHW Sys 1 Repair Conditioned HVAC1 350 9 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 CERTI,fE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD C*RF-01 Project ame: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall ex ex res R-13 Wall 0 Left 432 61 90 Existing No E Wall ex ex res R-13 Wall 90 Back 432 9 90 Existing No S Wall ex ex res R-13 Wall 180 Right 350 90 Existing No W Wall ex ex res R-13 Wall 270 Front 432 43.6 90 Existing No Roof 2 ex res Default 1978 to present 1240 Existing No N Wall Repair R-13 Wall 0 Left 250 64 90 Altered N/A E Wall Repair R-13 Wall 0 Left 432 64 90 Altered N/A S Wall Repair R-13 Wall 0 Left 630 72 90 Altered N/A W Wall Repair R-13 Wall 0 Left 432 64 90 Altered N/A OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 06 07 08 09 10 11 12 13 Name Zone Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt(deg) Roof Reflectan ce Roof Emittance Framin g Factor Status Verified Existing Condifion Roof Repair R-30 Roof rafter Left 350 0 0 0 0 0.1 0.85 0.1 New N/A ATTIC 01 02 03 04 06 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic ex res Attic Roofex res Ventilated 3 0.1 0.85 No No Existi No ng Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE•HOD C*RF-01 Project 'PTE Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xm1 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Verified Existing Status Condition 3x3 no damage N Wall ex (Left -0) - - 1 9.0 1.19 0.83 Insect Screen (default) Existing No 5x4 no damage N Wall ex (Left -0) - - 1 20.0 1.19 0.83 Insect Screen (default) Existing No 8x4 no damage N Wall ex (Left -0) - - 1 32.0 1.19 0.83 Insect Screen (default) Existing No 6x6.7 no damage E Wall ex (Back -90) - - 1 9.0 1.19 0.83 Insect Screen (default) Existing No 6x4 altered .48-.24 N Wall (Left -0) - - 1 64.0 0.48 0.24 Insect Screen (default) Altered N/A 6x4 altered .48-.24 2 E Wall (Left -0) - - 1 64.0 0.48 0.24 Insect Screen (default) Altered N/A 1x4 altered .48-.24 S Wall (Left -0) - - 1 4.0 0.48 0.24 Insect Screen (default) Altered N/A 6x4 altered .48-.24 3 S Wall (Left -0) - - 1 64.0 0.48 0.24 Insect Screen (default) Altered N/A 1x4 altered .48-.24 2 S Wall (Left -0) - - 1 4.0 0.48 0.24 Insect Screen (default) Altered N/A 6x4 altered .48-.24 4 W Wall (Left -0) - - 1 64.0 0.48 0.24 1 Insect Screen (default) I Altered N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition 23.5 ex W Wall ex 23.5 0.50 Existing No 20.1 ex W Wall ex 20.1 0.50 Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-10-06 12:56:35 CERTI9E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE C. C RF -01 Project ame: Roquemore Residence Ca culation Date/Time: 12:56, Tue, Oct 06, 2015 Page 5 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xmi OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 120 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd Repair 350 40 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofex res Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below - Cavity/Frame:. R-9.1 /2x4 Default 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 aQ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Inside Finish: Gypsum Board • Cavity/ Frame: R -30/2x10 • Roof Deck: Wood Siding/sheathing/decking R-30 Roof rafter Cathedral Ceilings Wood Framed Ceiling 2x10 @ 16 in. O.C. R 30 0.037 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab ex ex res 1240 120 None 0.8 No Existing No Slab -on -Grade Repair 350 40 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Altered No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE tOD C*RF-01 Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 6 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 1590 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntdFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-10-06 12:56:35 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD C*RF-01 Project Name: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 7 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct I— — Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 1 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A I— — IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name . IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 PROJECT NOTES Fire Damage Repair Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 CERTIVTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEtOD C*RF-01 Project ame: Roquemore Residence Calculation Date/Time: 12:56, Tue, Oct 06, 2015 Page 8 of 8 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Fire Damage 53-700 Ave. Martinez-Peck-15.xml DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon Scott Company: Signature Date: Scott Design and Title 24, Inc, 10/6/2015 Address: CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/StatePliln.m Desert, CA 92211 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: William M. Peck Company: Date Signed: Consulting Structural Engineers Address: License: PO Box 2783 City/State/Zip: Phone: Corona, CA 92878 (951) 674-7848 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-10-06 12:56:35 Ah • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Roquemore Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 10/6/2015 Project Address 53-700 Avenida Martinez La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,590 Addition 350 # of Units 1 INSULATION Construction Type Area Cavi (ft)Special Features Status Roof Wood Framed Attic R11 1,240 Existing Wall Wood Framed R 13 1,532 Existing Door Opaque Door - no insulation 44 Existing Slab Unheated Slab -on -Grade - no insulation 1,590 Perim = 160' Existing Demising Wood Framed - no insulation 429 Existing Roof Wood Framed Rafter R 30 350 New Wall Wood Framed R 13 1,480 Altered Demising Wood Framed R 13 350 New FENESTRATION Total Area: 334 GlazingPercentage: 21.0 b New/Altered Average U -Factor: 0.48 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Left (N) 61.0 1.190 0.83 none none Bug Screen Existing Rear (E) 9.0 1.190 0.83 none none Bug Screen Existing Left (N) 264.0 0.480 0.24 none none Bug Screen Altered HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.66 All Pipes Ins Altered EnemyPro 6.7 by EnemySoft User Number: 6712 RunCode: 2015-10-06T12:57:04 ID: Pae 11 of 15 4 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may annly. Review the respective Inde sectinn fnr mnre infnrmntinn_ Building Envelope Measures: §I10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain ' Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1R. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § I50.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § I50.0(e)I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § I50.0(e)I B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § I50.0(e)I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation §110.3(c)5: valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §I10.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 4 2613 Low -Rise Residential Mandatory Measures Summary § I50.00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)1 l: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §I50.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy 5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency §I 10.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat settin • a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 4 4 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § 150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §I50.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §I50.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it §I50.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5• and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the ' functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0(k)2. §150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § I50.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, $130.4, $140.7 and § 141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D '130.4, shall comply with the applicable requirements in 110.9 130.0, §130.2, 140.7 and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in 110.9, 130.0 130.2 130.4, 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in 110.9 130.0 130.1 130.4 140.6 and 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.10 e . §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of $110.10 b through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §I 10.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 0 44) 4x N r Q J 2 - a N G J41) 0