Loading...
SFD (13046)53725 Avenida Martinez 13046 T a 0 4hf 4 4 a" Building Address 53"725 Martinez Owner La Quinta Cove Home, Inc. Mailing Address 310 Washington, Ste. P214 P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 City Zip Tel. Santa Konica, GA 90293 1 (310) 827--0171 Contractor Same City lZip I Tel. State Lic. I City & Classif. Lic. # fir Arch., Engr., Barry A. Berkufs AZA Designer + Address Tel. 223 De La Guerra CityState Santa BarbaraZip CA 33341 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section 7DOO) of Division 3 of the.-Busindss and Professions Code, and my license is in full force and SIGNATURE" "" " ' DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) or Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (8500). ❑ I,as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner or property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within one year or completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars (8100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: g, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. BUILDING: TYPE CONST. OCC. GRP. A.P. Number 774"131"423 Legal Description Lot 11 Block 244 Project Description SPD 13046 Sq. Ft. 1694 Size No. No. Dw. Stories Units New [X Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit does not include any block walls or pool. Estimated Valuation $99,559.80 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 541.94 Const. $39.50 Mech. _ 62.80 Electrical 132..75 Plumbing 144.00 S.M.I. 10.00 Grading 20.40 Driveway Enc. --- Infrastructure 2,201.83 AXXXXXXX Precise Plan 25.00 TOTAL 3,777.02 REMARKS n TY ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS COLL. AREA i ROUGH PLUMB. YARD SPKLR SYSTEM 2ND FL. SQ. FT. @ HEATING (ROUGH) STORAGE TANK FORMS MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® DUCT WORK ROCKSTORAGE FOUND. REINF. POWER OUTLET ROOF DRAINS GAR. SO. FT. ® HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) DRAINAGE PIPING CAR P. SQ. FT. ® WALL SQ. FT. ® WATER HEATER DRINKING FOUNTAIN FINAL INSP. URINAL SQ. FT. ® WATER SYSTEM ESTIMATED CONSTRUCTION VALUATION $ GRADING cu. yd. —Plus—X$—=$ WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. Z—1-CJ3 FLOOR DRAIN MECHANICAL FEES ROOFING � _�,.� � � WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL INSULATION/SOUND SQ.FT.GAR ® lAc HOUSE SEWER FINISH GRADING GAS PIPING PERMIT FEE .p FINAL INSPECTION / Z-Z� l PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE 7 2p 13 GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM $ GRADING cu. yd. —Plus—X$—=$ LUMBER GR. FINAL INSP. Z—1-CJ3 FRAMING .f z c �C "V FINAL INSP. Z�u.O�$ J ROOFING � _�,.� � � �� (n J/ •� 0 -A C'L N.— _9 REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL .27 LATHING 9-� MESH INSULATION/SOUND FINISH GRADING .p FINAL INSPECTION / Z-Z� l CERT. OCC. FENCE FINAL INSPECTOR'S SI -GN ATURESIIN. ITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 6/23/93 1 Type of Permit ILa Quinta No. 112286 Permit # Owner Name La Quinta Cove Home, Inc. Log No. Street See Below city La Quinta Zip 92253 Study Area 113 APN # I I Tract # Lot # 0 Square Footage 115246 Type of Development Single Family Residence No. of units Comments 53-683 Avenid_aAlvardo, 52-415 Avenida Mendoza, 52-140 Avenida Velasco, -52-675 Avenida Rhin, 52-375 Avenida Navarro, 52-790 Avenida C'arranza, 4.1-Rln Villa S9 -19S Avanirla HPrrara51-77S Auanid;i MV rl-invv At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 x 15 246 or $ 25,155.90 have been paid to D.S.U.S.D, for - the'.property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By La Quinta Cove Home, Inc. Telephone 564-5540 Name on the check By ' jams F. T.ivply Assistant Superintendent, Business Services Fee collected /exempted by Vickie J. Durrett Payment Received Signature /acvcheck rsa. 054138 Collector. Attach a copy of county or city plan check application form to district ropy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting .' I t,4vr e I &t It %zjx of Illy,I ?,,. RF o'er T -k -S.., uu Tit of 14d Ouinta 1111itbing anb 'afjot 31illi"mon This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 53-725 Martinez Use Classification syn Bldg. Permit No. 11046 Group Ri Type Construction VN Fire Zone Use Zone S La Quinta Cove Home, Inc. 53-725 Martinez Owner of Building Address LQ CA. LONNIE DAY C i tX,. By; Date: 1 9-21-9-4 Building Official r POST IN A CONSPICUOUS PLACE Title 24 Report For: HARLAN LEE THE COVE 92259M December 3, 1992 These plans) and calculations comply, substantially with the 1992 California Energy . Commission Regulations for Residential Buildings:. Title 24, Parts 1 and 6 Richard A. Palmer Energy Management Engineering, Inc. 1910 E. Warner, Suite A Santa Ana, CA 92705 (714) 261-5704 ORDER OF CONTENTS 1. Instructions for Compliance Documentation 2. CF-1R Forms (Certificates of Compliance) 3. MF1 Forms (Mandatory Measures Checklist) 4. Title 24 Ughting Requirements 5. Forms 3R (Construction Assemblies) 6. C-2R Forms (Computer Method Summary) 7. Heating and Cooling Calcs INSTRUCTIONS FOR COMPLIANCE DOCUMENTATION These calculations reflect the new 1992 Second Generation Residential Energy Standards. Numerous changes have been incorporated into the new procedures, including the documentation which is required to be incorporated into the plans. To minimize plan check and field problems, the following information should be put on. the plans: 1. CF -1R Form (Certificate of Compliance): Each plan must have a CF -1R Form submitted with the calcs, as well as on the drawings. The form, developed by the CEC, summarizes the energy conservation features required for compliance. The CF -1R Form is 3 pages per plan, the third page being a signature page for owner, architect and energy consultant to sign. Though all three sheets for each plan must be submitted with the calcs, we recommend putting only one page for signatures on the plans. This reduces redundancy in signing. Whether the plans must be wet signed or not will vary depending on the building department. 2. MF -1R Form (Mandatory Measures. Checklist): This is a one page checklist of building features that are required of all residential buildings built in California. These must be on the plans as well as in the calcs. 3. A Heating and Cooling Load Summary must be provided. It has been incorporated as the second page of the CF -1R- 4. The convention for Orientation description is as follows: Direction Azimuth (Clockwise Rotation) Orientation 1: Front to North 0 degrees Orientation 2: Front 'to East - 90 degrees Orientation 3: Front to South 180 degrees Orientation 4: Front to West 270 degrees CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1 R Project Title: THE COVE Date: 12/ 3/1992 Project Address: LA QUINTA HARLAN LEE Documentation Author: Company: R. A. Palmer & Associates Telephone: (714) 261-5704 Compliance Method: MICROPAS4 by Enercomp, Inc. Climate Zone: 15 Building Permit # Plan Check / Date Field Check/ Date MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF -1 R User#-MP0265 User -Richard A. Palmer & Associates PLAN 1 GENERAL INFORMATION Conditioned Floor Area: 1594 Building Type: Single Building Front Orientation: Cardinal Number of Dwelling Units: 1 Number of Stories: 1 Floor Construction Type: SlabOnGrade Infiltration Control: Standard BUILDING SHELL INSULATION Component Insul .Assembly Type R -value U -value Location/Comments SlabEdge 0 0.72. No Insui SlabEdge 0 0.50 R-7 Equiv. Wall 15 0.081 ext Wall 15 0.075 garage Roof 30 0.033 attic THERMAL MASS Manufacturer and Model #: American GV2F90-533T (or approved equal) SPECIAL FEATURES/REMARKS Area Thickness Cvr R -Val Type (sf) (in) 0=Exposed Location/Comments SlabOnGrade 65 3.5 0.0 kitchen SlabOnGrade 75 3.5 .0.0 entry SlabOnGrade 24 3.5 0.0 bath 2 SlabOnGrade 8 3.5 0.0 .,fireplace hearth SlabOnGmde 1521 3.5 2.0 carpeted slab WATER HEATING SYSTEMS Number Tank Extemai In Energy Size Insulation System Type Heater Type . Distribution Type System Factor . (gal) R -value Storage Gas Standard 1 0.60 50 6 Manufacturer and Model #: American GV2F90-533T (or approved equal) SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title: THE COVE Date: 12/ 3/1992 Project Address: LA QUINTA / HARLAN LEE MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF, -1 R User#-MP0265 User -Richard A. Palmer & Associates PLAN 1 GLAZING Glazing Area U- # of Interior Exterior Framing Orientation (sf) value Panes Shading Shading Overhang Type ENT 6 0.67 2 none 6 Metal Front DEN Front 30 0.82 2 Roller.Wht 1 Metal BRS Left 50 0.82 2, Roller.Wht 1 Metal MBA Left 5 0.82 2 Roller.Wht 1 Metal MBA2 Back 5 0.82 2 Roller.Wht 1 Metal MBR Back 15 0.82 2 Roller.Wht 1 Metal SLDR Back 53.4 0.72 2 Roller.Wht 1 Metal LIV2 Back 16 0.67 2 none 1 Metal LIV3 Back 10 0.82 2 Roller.Wht 1 Metal SLDR2 Right 53.4 0.72 2 Roller.Wht 1 Metal LIV DIN Right 40 0.82 2 Roller.Wht 1 Metal KIT Right 10.5 0.82 2 Roller.Wht 1 Metal DEN2 Right 12.5 0.82 2 Roller.Wht 1 Metal ASSUMED HVAC SYSTEMS Assumed Duct Duct Assumed System Efficiency Location R -value Gas 0.78 Attic 4.2. AirCond 11.0 Attic 4.2 ACTUAL HVAC SYSTEMS HEATING LOAD: HEATING EQUIP: COOLING LOAD: COOLING EQUIP: PLAN: 1 38931 BTUH STD CARRIER 58PAV075JC 36400 SENS p112.F CARRIER 38TMO48 60953 BTUH MAX 80.0. (78% MIN) 47320 BTUH TOTAL. CARRIER CD5AA048 71000 BTUH 3.94 TONS 39450 BTUH (9) ARI 11.00 SEER(11.0 MIN) CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 Project Title: THE COVE Project Address: LA QUINTA / HARLAN LEE MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF -1 R User#-MP0265 User -Richard A. Palmer & Associates CF -1 R Date: 12/ 3/19VZ COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, parts 1 and 6 of the calffomia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. OWNER ENFORCEMENT AGENCY Name: Name: Company: HARLAN LEE Title: Address: 310 WASHINGTON BLVD Agency: MARINA DEL REY CA 90292 Phone: 310 827-0171 Phone: License: Signed: Signed: Date: Date: DOCUMENTATION AUTHOR Name: R. A. Palmer Company: Richard A. Palmer Assoc. Address: 1910E Wa Santa A Phone: (714) iL P4 Ey Signed: y Date: o II 9 '!1, ECHA N C; OF Cil Mandatory Measures Checklist: Residential MF -1 R MOTE: Lowrlse residential Duildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed or. the Certificate of Compliance. When this checklist is incorporated into the permit documents. the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION DESIGNER ENFORCEMENT Building Envelop -0 Moasures X X • §I50(a): Minimum R-19 ceiling insulation. X §150(b): Loose fill insutation manufacturer's labeled R -Value. X • §I50(c): Minimum R-13 wall insulation in framed walks (does not apply to exterior mass walls). X • §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. §150(Q: Stab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no N/A greater than 2.0 pem>lnch. X §118: Insulation specified or installed meets Cafifomia Energy Commission quality standards. Indicate type and form. X §116-17: Fenestration Products, Exterior Doors and InfiltratioNExidtration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. X N/A §150(Q: Special infiltration. barrier installed to comply with §151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and tactory-built fireplaces have: a Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X X §110-13: HVAC•equipment, water heaters, showerheads and.faucets certified by the Commission. X §150(): Setback thermostat on all applicable heating systems. X §150@: Pipe and Tank Insulation 1. Indirect hot water tanks (e.g.. unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interiodexterior insulation (R-16 or greater). 2. Fust 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (144 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55OF insulated. 5. Piping insulated between heating source and indirect hot water tank. * §150(m): Ducts and Fans 1. Ducts constructed. installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within con clitioned space. 2. Exhaust fan systems have backdraft or automatic dampers 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.. X N/A §114: Pod and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions. no electric resistance heating and no pilot light- ight2. N/A 2.System is installed with: a At least 36' pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa 3. Pool system has directional inlets and a circulation pump time switch. X §115: Gas-fired central furnace, pod heater, spa heater or household cooking appliance have no :\ continuously luring pilot light (Exception: Non -electrical cooking appliance with pilot < 150 BtuRu.) J Lighting Measures §150(k): 40 Iumenstwatt or greatcx for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cove() approved. X RevlBad January 1992 LIGHTING MEASURES Installing energy-efficient lamps and fixtures can reduce lighting energy costs without sacrificing the quality or quantity of light available. Kitchen Lighting The Standards require that general lighting in kitchens have.an efficacy of at least 40 lumens per watt and be controlled by the most accessible switch(es) in the kitchen. The light switch location determines how the occupant will use the lighting. Luminaires used only for specific decorative effects (and which are not the only luminaires in the kitchen) need not meet this requirement. .B A" must be fluorescent General lighting is lighting designed to provide a uniform level of light distribution throughout a space. This can be achieved by light fixtures in the ceiling or around the perimeter of the room. . Lighting fixtures under cabinets may meet the general lighting requirements if they provide uniform light distribution in the kitchen (see Figure 2-11). A luminaire which is the only Lighting in a kitchen will be considered general lighting. "A" mustbefluoreseent All of "C" roust be fluorescent "A" or all of "C' must be fluorescent Kitchen Lighting Examples Bathroom Lighting The Standards require.that each room containing a water closet must have at least one luminaire with lamps with an efficacy of at least 40 lumens per watt. As an alternative, this requirement may be met by installing the high efficacy luminaire in an adjacent room that has complementary plumbing fixtures. If there is more than one luminaire in the room, the high -efficacy luminaire must be switched at an entrance to the room. "A" must be fluorescent A E B "A" . "B" or "E' must be fluorescent Bathroom Lighting Examples General Luminaires installed to meet the 40 lumens per watt requirements cannot contain medium base incandescent lamp sockets, and must be on separate switches from incandescent lighting. All incandescent lighting fixtures recessed into insulated ceilings must be approved for zero -clearance insulation cover (LC.) by Underwriters Laboratories or other testingtrating . laboratories recognized by the International Conference of Building Officials (ICBO). Recessed lighting fixtures left uninsulated significantly increase the heat loss and heat gain through the roof/ceiling area. "A" must be fluorescent; "D" can be incandescent E B ._.a i c:= IF "B" or "E" must be fluorescent A lM Proposed Construction Assembly: Residential Form 312 Project Title D31c Project Addrt-c< Building Permit M Documentation Author Telephone R-1 5 WALL WS 1 5G Qtedccd B /Date ALcemhly Name Enforcement Agency Use Only Sketch of Construction Assembly . Assembly Type: (check one) Floor X Wall Ceiling/Roof Framing Material: Wood Framing Size: 2 x 4 FramingSpacing: 16 O.C." Framing Percentage: Wall: X 15% (16" ox-) (check one) 12% (24" o.e.) Floor/Ceiling: 10% (16" ox.) 7% (24" o.c.) Wall Weight / sf: (Packagesonly) List of Construction Components R -Value Cavitv(Rc) Frame(Rt) Outside Surface Air Film 0.17 0.17 1. STUCCO - 0.18 0.18 2. R-15 INSULATION 15.00 3. BUILDING PAPER 0.06 0.06 4. 2 X 4 FRAMING r 3.46 5- 1/2" GYPSUM 0.45 0.45 6. 7. Inside Surface Air Film 0.68 0.68 - Total Unadjusted R -Values: 16 .54 5.00 ' Rc Rr . Framing Adjustment Calculation (if applicable): ( 1/16.54 x 1-15/100 ) + ( 1/5.00 x 15/100 ) _ i /Re 1 -(Fr%/ 100) t I /R f FrIfo/100 1/rotal U -Value 0.081 Total U -Value `Probosed Construction Assembly: Residential Forin 3R rrojeet Tittc Project Address Documentation Author T R— 15 GARAGE WALL .WG 1 5G Assemhlr Name Sketch or Construction Assembly Date Building Pcnnit r Checked ByLDatc Enforcement Agency Use only Assembl v Tvpe: Floor (check one) X Wall Outside Surface Air Film 0.68 Ceiling/Roof L 1/2" GYPSUM Framing Material: Wood 2. R-15 INSULATION Framing Sze: 2 x 4 3. BUILDING PAPER Framing Spacing: 16 4- 2 X 4 FRAMING Framing Percentage: WaIL-- X 15% (16 ox-) (check one) 0.45 12% (24' OC.) Floor/Cci7 g: 10% (16' o c.) 7% (24' o.c.) Nall Weight / sf-- 0.68 Total Unadjusted R -Values: 17.32 (Packages only) R, `) List of Construction Components R -Value CavitvW Frame(Rr) Outside Surface Air Film 0.68 0.68 L 1/2" GYPSUM 0.45 0.45 2. R-15 INSULATION 15.00 3. BUILDING PAPER 0.06' 0:06 4- 2 X 4 FRAMING 3.46 5- 1/2" GYPSUM 0.45 0.45 6- 7- - Inside Surface Air Film 0.68 0.68 Total Unadjusted R -Values: 17.32 5,51 R, 'Rr Framing Adjustment Calculation (if applicable): ( 1/ 17.32 x 1-15/100 ) + ( 1/5.78 x 15/100 ) = 0.075 1/Re 1-(Fr%/100) 1/R( Fr%1100 Total U -Value = 13.34 1/iotal U -Value Total R -Value i COMPUTER METHOD SUMMARY Page 1 C. Project Title.......... THE COVE Date ..... N12/03/92 Project Address..... .. LA QUINTA HAR.LAN LEE Documentation Author... Building Permit Company ................ Richard A. Palmer & Assoc Telephone .............. 714 261-5704 Plan Check / Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 I MICROPAS4 v4.00 File -92259M11 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1 = MICROPAS4 ENERGY USE SUMMARY = -0.95 = = Energy Use Standard Proposed Compliance _ _ (kBtu/sf-yr). Design Design Margin = - - pa g:......... space Heating 2.40 2.23 0.17 = - - space ce Cooling..... 30.42 31.99 -1.57 = . - - = Water Heating.......... 13.11: 11.69 1.42 = = North Total.' 45.93:. 45.91 0.02 = = Space Heating:..'.:.'.:.:' 2.40 2.52- -0.12 = - Space Cooling.......... 30.42 30.06. 0.36 _ - Water Heating.....:....` 13.11 11.69 1.42 = = East Total' 45.93", 44.27 1.66 = GENERAL INFORMATION 2' 28 012 = = Space = Space Heating.. .... Cooling...:'.:...'. 2.40 30.42 .31.37, -0.95 = = Water Heating.......... 13.11 11.69 1.42 = = South Total -°d__... 45.93•-- 45.34 0.59 = = Space Heating.'.:: a.:. 0 2.40 =-: 1.96y 0.44-.. _ = Space Cooling::.::: `::':: 30:42 31.80 - - -1.38 ... _ = Water Heating.. 13.11 11.69 1.42 = = West•Total 45.93 = 45:45 0.48 _ *** Building "cai'piies with"Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 1694 sf Building Type....... .... Single Family Detached Y Construction Type New Building Front Orientation. Cardinal - N,E,S,W r„ L Number, of Dwelling Units... 1= Number of Building Stories. Weather Data Type.......... ReducedYear COMPUTER METHOD SUMMARY Page 3 C -2R Project'Title.......... THE COVE Date........ 12/03/92 MICROPAS4 v4.00 File -92259M11 Wth-CTZ15S92 Program -FORM C -2R I User#-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1 I FENESTRATION SURFACES SC SC Interior Area # of Frame Open U- Act Glass Int Shade Surface (sf) Panes Type Type value Azm Tilt Only Shade Description 7 Door 53.4 2 Metal Slider 0.72 180 90 0.88 0.40 Roller.Wht 8 Window 16.0 2 Metal Fixed 0.67 180 90 0.88 0.78 none 9'Window 10.0 2 Metal Slider 0.82 180 90 0.88 0.40 Roller.Wht 10 Door 53.4 2 Metal Slider 0.72 270 90 0.88 0.40 Roller.Wht 11 Window 40.0 2 Metal Slider 0.82 270 90 0.88 0.40 Roller.Wht 12 Window 10.5 2 Metal Slider 0.82 270 90 0.88 0.40 Roller.Wht 13 Window 12.5 2 Metal Slider 0.82 270 90 0.88 0.40 Roller.Wht OVERHANGS AND SIDE FINS Window-- ------Overhang ---Left Fin--- Right Fin -- Area Left Rght Surface (sf) Hght Wdth -Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 6.0 2 n/a 6 2 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window_, 30.0 5 n/a,,,_. 1 1 n/a n/a n/a n/a n/a n/a n/a n/a .3 Window 50.0 5 _ n/a. 1 , . 1,, n/a n/a n/a n/a n/a n/a n/a n/a 4 Window_ . 6.0.3.. n/a_,e. 1 1 n/a ._n/a n/a n/a n/a n/a n/a n/a. 5 Window 6.0 1.5 n/a 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 15.0 5 n/a 1 5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Door 53.4 6.7 n/a 1 6 n/a n/a n/a .n/a n/a n/a n/a n/a 8 Window. 16.0 2 n/a 1 4 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 10.0 5 n/a 1 2 n/a n/a n/a n/a n/a n/a n/a n/a 10 Door 53.4 6.7 n/a 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 40.0 5 n/a 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 10.5 3.5 n/a 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 12.5 5 n/a 1 1 n/an/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface Mass Type .(sf) (in) Cap ivity R -value Location/Comments HOUSE 1 SlabOnGrade 66 3.5 28.0 0.98 R-0.0 kitchen 2 SlabOnGrade 75 3.5 28.0 0.98 R-0.0 entry 3 SlabOnGrade 24 3.5 28.0 '0.98 R-0.0 bath 2 4 SlabOnGrade 8 3.5 28.0 0.98 R-0.0 fireplace hearth 5 SlabOnGrade 1521 3.5 28.0 0.98 R-2.0 carpeted slab SLABEDGEI RICHARD A. PALMER & ASSOCIATES PAGE 1 4350 4350 RESIDENTIAL CALCULATIONS 25 0.50 475 (ASHRAE METHOD) FRAMEWALL 966 0.081 DATE: 03 -Dec -92 Tosa = 32 (winter design db) JOB NO: 92259M Tinside= 70 (winter) CLIENT: HARLAN LEE dTEMP = 38 (winter) PROJECT: THE COVE AC/HOUR= 0.9 (winter) LOCATION: LA QUINTA VOLUME = 16940 (cf) PLAN NO: 1 ATTIC Al 1694 FLOOR AREA: 1694 sf 2253 ROOF R1 ---- HEATING LOAD ---- 0.051 ITEM AREA U -VALUE TRANS. INFILT. TOTAL 1.13 (sf) (Btu/h- LOSS LOSS (Btu/h) 308.8 0.75 sf-F) (Btu/h). (Btu/h) 8801 SLABEDGEI 159 0.72 4350 4350 SLABEDGE2 25 0.50 475 475 FRAMEWALL 966 0.081 2973 2973 PARTFWALL 200 0.075 570 570 FLR O/GAR 0 0.047 0 0 EXP FIR 0 0.047 0 0 RAISE FLR 0 0.040 0 0 ATTIC Al 1694 0.035 2253 2253 ROOF R1 0 0.051 0 0 GLASSI 0 1.13 0 0 GLASS2 308.8 0.75 8801 8801 SKYLIGHTI 0 1.23 0 0 SKYLIGHT2 0 0.7 0 .309 0 INFILT.. ((ac/h)*(vol)*1.09*dT)/60 10525 10525 HEAT LOSS: SUM = 29947 STD OUTPUT CAP: SUM*1.3= * 38931 MAX OUTPUT CAP: (SUM+(10*FL0ORAREA))*1.3= 60953 -or-, MAX= 45000.Btu/h (whichever is greater) 45000 --- SUMMARY OF HEATING AND COOLING LOADS --- -- AS CALCULATED BY RICHARD A. PALMER & ASSOCIATES,INC. -- COOLING: FRONT TO NORTHWEST HEATING:..@32F ODB 36400 BTUH SENS @112F ODB 29947 BTUH HEAT LOSS 47320 BTUH TOTAL 38931 BTUH STD CAP 3.94 TONS 430 SQ FT/TON 60953 BTUH MAX CAP ----PROPOSED FURNACE SELECTION ---- OR STATE APPROVED EQUAL FURNACE MAKE & MODEL NO: _.---_-CARRIER _ SBPAV075JC •AFUE: 80.0.. (78% MIN) OUTPUT CAPACITY: = 71000.:BTU/HR -- - - - CFM(COOLING) : w_ _ _ 1545 CFM ----PROPOSED COOLING EQUIPMENT ---- OR STATE APPROVED EQUAL Y CONDENSING -UNIT MAKE & MODEL -NO:. __.CARRIER 38TMO48 COOLING COIL MAKE & MODEL NO: CARRIER CD5AA048 TOTAL COOLING CAPACITY: 39450 BTU/HR @'112 SEASON ENERGY EFFICIENCY RATIO: 11.00 SEER(11.0 MIN) * MINIMUM R-4.2'INSULATION REQUIRED ON DUCT IN UNCONDITIONED SPACE .RICHARD A. PALMER & ASSOCIATES PAGE 3 RESIDENTIAL CALCULATIONS (ASHRAE_METHOD) DATE: 03 -Dec -92 PROJECT: THE COVE JOB NO: 92259M LOCATION: LA QUINTA CLIENT: HARLAN LEE PLAN NO: 1 FLOOR AREA: 1694 sf -- COOLING LOAD SUMMARY BY ORIENTATION -- FRONT TO NORTH FRONT TO NORTHEAST 35697 BTU/HR SENSIBLE 35869 BTU/HR SENSIBLE 46406 BTU/HR TOTAL 46629 BTU/HR TOTAL 3.87 TONS 3.89 TONS FRONT TO EAST FRONT TO SOUTHEAST 34473 BTU/HR SENSIBLE 35247 BTU/HR SENSIBLE 44814 BTU/HR TOTAL 45821 BTU/HR TOTAL 3.73 TONS 3.82 TONS FRONT TO SOUTH FRONT TO SOUTHWEST 35064 BTU/HR SENSIBLE 35779 BTU/HR SENSIBLE 45584 BTU/HR TOTAL 46512 BTU/HR TOTAL 3.80 TONS 3.88 TONS FRONT TO WEST FRONT TO NORTHWEST 35004 BTU/HR SENSIBLE. 36400 BTU/HR SENSIBLE 45505 BTU/HR TOTAL 47320 BTU/HR TOTAL 3.79 TONS 3.94 TONS AUG 16 'y_; 11:'5C1A1*-I BARRY A BERK I'; AIA 0 0 r V H 13ARR\/A.BF,KKLis A.1.A. August 16, 1993 Harlan Lee & Associates 310 Washington boulevard Marina Del Rey, CA 90292 Attn: Randy Dear Randy: Per our phone conversation, I would like to clarify the location of the footing omission described in the letter from Carl Schneider on August 12, 1993, 1. Due to the fact that the 3 -point bearing trusses have been redesigned as 2 -point bearing trusses, the footing running the length of the house dividing the LIVING/DINING areas from the SLEEPING areas may be omitted. (not required) If you have any further questions, please call. Sincerely, Barry A. Berkus, A.I.A. Scott Branch f"A WV 6F LA QUINTI, , 223 L. UC La Guorra Y+I Ia U irp3r3, CA 93101 Y..U5 9ti;f-ts'dU1 Fax: SOS1966.6646 P. 2/2 O k%] JUL 13 "93! ll:22At'I—BARRY A BERKUS AIA r I P. i/2 X, 2 AAC I ACCEP7 EG FQq SUBJEC F TO INS'T' LLIL A, T;!. 'o : $I AND ;FL--Li- CI DATE 1 G/--'%1 IK I r"'N A -,rr ) K 1 PI A K I z 51 ic /A. SPAN 40- 0- a (FT. I*_-4ES. 16THS) SCALE= 0.152/1.0 1 CBO DESIGN CRITERIA FOLLOWED BOULDER -COLORADO -80301 taJanaaooe nLa.o m tic shoo lasbsoo prsprrod as by sa apaiateed W ood ttvu labviatae Ccnoc"w Ptasra sbaU bamredw usrd by 1,1ETAL LOCI: .20 ar l g gauge A nN A446 lbs dei ochres vy sapaeb-bri for dow pts ass reach of vnaonotott infoeratims spocif. Yodc A aban" hot dipped gafvaniudssecL lAnbomaiausc coroeee mug be 39%as (car q Ilac LINCOLN TRUSS catsns OfFued by the ct ma The fabrx"i a Ka traction of mares an wee as the ab"k of limo of fabrication. m. „itt tm .gbi aei>,aowtrttmuss IN" bow 284 SOUTH 8th S-. Acayreie+. taooeti00enmsooenedtsigssrsdardaofl.OSsadTPf.7%wdmpassama Trouts thaDbela+reed-iL%cmp6wLoQocaonroavoiddamage. Tcw?aosybo,cimgmoube BANNING, CA. 92220 court chards an cosums"ariy absa►\od b> MV4 aeata "I and seffinm chards ass cater used when enacting wmacs (sac BWT•76 for TPI mcon mcndasices Bracing "we m drawing aian+dyabasajcram M.daic%&m mv.e=foGcvaos.DcsiyaaasvipUtatadcgwtcdain.yc iswnuistbocYfia;anthe meaber&aip wdy.Itisam rind toIatcrsl)"4baacuywovuaU w a'Pcprwidtdtjbp=vcsboadiag doi$a bracing which is dace by orhets. Referw JILT 20 (WI) fw mefty oc ded tnus is fie w iod oi&A crow lis-upossbu Y is auumd ba ovuaU buildiag design. ha,adtag an4cr%cuoa. Dcsip Wadi sho dd not be applied Weil shuChis4 and bracilS ue eomplas. LEN FORCE MBR LEN FORCE" NOR FORCE MBR FORCE JT PLATE OFFSET-H OFFSET-L JT PLATE OFFSET-M OFFSET-L t 2 5.54 -1918 11-12 5.54 1740 2-20 52 8-15 -2888 1 3X 6 11 3X 6 2 5.68 -1515 12-13 3.B8 1743 2-19 -369 8-14 1057 2S SX 6 3 1/4 3 12 2X 4 4 4.32 -21373-14 1.B1 1548 3-19 351 9-14 -902 3 5X 6 2 1/8 3 13 4X 4 S 4.32 1973 14-15 4.32 962 3-18 -1462 9-13 832 4 5X 6 14 5X 6 E 2.02 1974 15-16 2.29 -1401 4-18 903 10-13 -222 5S 5X 6 3 1/4 3 15 5X 6 7 2.29 2989 16-17 2.D2 -2987 4-17 -2550 10-12 33 6 5X 6 16 5X 12 t 2 1/2 3 1/2 7 6 4.32 1403 17-IB ,4.32 214 5-17 -237 7 5X 6 17S 7X 8 3 1/4 4 S 1.81 -1036 18-19 4.32 1411 6-17 21511 8 7X 8 2 1/8 4 t8 4X 4 1D 3.88 -1628 19-20 68 1793 6-16 -1889 9 4X 4 19 5X 6 I11 5.54 -1867 20- 1 5.54 1790 7-16 -2629 105 5X 6 3 1/4 3 20 2x 4 21 1 1.00 11' 7-15 1649 1SPLLIIC 22-11 1.00 11 : BLOCK 2 0.80 -9 ► 4 Q Ofd 14q0.'80a LUMBER SOLUTION J REACT MIN CJ1I[T d 3. Ia18R FORCES ANO RX ARE FOR 1 PLY OF 2 6 F OP 2X4 OFL /1 TOP PANEL 6- 7 CSI- 0.750 1 4122. 4.41- NAIL TRUSSES TOGETHER AS NOTED: T 2X4 DFL 11 1 662. 3.50' T/C:10d COMMON NAILS 010.50 IOC ^' . No. C045522 m T PANEL 19-20 CSIs; 0.360 B/C :10d COMMON NAILS 012.00 IOC d Q0 2X4 HF STUD NDN-STRIICT FRAYING LLA am WEB : 10d CONAON NAILS 012.00 IOC C f? 3194 CHD 2X4 DFL /1 Q' BLK 2X4 HF STUD qrf NOIi-ST fR+WIW PLATES Cnara Eno Blks 2x4-20 of getter S :a CAJUL F F•Gpl1 BIOCIt4 Jx4-20 Of tsetter 3 5- a- 4 22- 0- 4 28- 7- 9 34- 3-13 T :1-G- 4 024 4- 3-12 5-10- 9 t- 1-5 11- 4- 7 /S- 8- • p2- 20- 24- 3-13 Q- 30- 5- 4 10•- b- O S- a- 4 4- 3-12 4- 1 2- 3- 9 2 1- 9-11 5__e- 3 DESIGN CRITERIA - TPI i i f TOP LL= 32.0 PSF TOP OL= 28.0 PSF 2x10 nailed w BOT LL= 0.0 PSF 5X6 - 5x6 - 5X6 3X6 - SX6 - 7x6 - 2" 'o 3 4 5 6 7 8 4X4 16d at- - C . DtJR OF LOAD I NCP1 .25 12 4.75 e 12 5X6 \ Q4.7S staggered IN /C P LATENC METAL-LOCK 5X6 f through-out t0 PLATE OUR INC- 1. 25 2 10 3xs - 4 support 3x6 - MOM-STANDARD 4x8with JT LOS LD CASE t 11 3 v 1530.0 1 0 o hunger 8 v 1530.0 1 13 V 1646.0 1 f 15 SECTION DIR LIVE DEAD LD CASE o 20 SX6 - 4X4 - 7X8 - 5X1295" - 5X6 4X4 - 112 0' 3- 8 V 112.0 98.0 t 21 2x4 I 2X4 1 22 TOTAL LOAD DEF 0 PANEL 19 = 0.209- 22- 0 404-- O Lf0EF=999 L= 264.2 REC CNBR= 0.2a" i TOTAL LOAD HOR DEF as 0.094- 1 Job •ART 1- I- 5 5- 6- 4 4- 3-12 4- 3-12 - 3- 1- 9-11 5- a- 3 VER: 428 1t- 4- 7 t5- 8- 4 20- 0- 0 24- 3-13 30- 5- 4 40- 0- 0 DATE DATE 7/30/93 0/93 5- a- 4 2- 0- 4 4- 3-12 3-10- s 5- 6- 4 22- 0- 4 28- 7- 9 34- 3•-13 NOTE: 1X 4 LAT.BRCG 0101t O/C MAX.REOD ON BOTTOM CHORD UNLESS OTHERWISE SHOWN KEYWARK ENGINEERING /A. SPAN 40- 0- a (FT. I*_-4ES. 16THS) SCALE= 0.152/1.0 1 CBO DESIGN CRITERIA FOLLOWED BOULDER -COLORADO -80301 taJanaaooe nLa.o m tic shoo lasbsoo prsprrod as by sa apaiateed W ood ttvu labviatae Ccnoc"w Ptasra sbaU bamredw usrd by 1,1ETAL LOCI: .20 ar l g gauge A nN A446 lbs dei ochres vy sapaeb-bri for dow pts ass reach of vnaonotott infoeratims spocif. Yodc A aban" hot dipped gafvaniudssecL lAnbomaiausc coroeee mug be 39%as (car q Ilac LINCOLN TRUSS catsns OfFued by the ct ma The fabrx"i a Ka traction of mares an wee as the ab"k of limo of fabrication. m. „itt tm .gbi aei>,aowtrttmuss IN" bow 284 SOUTH 8th S-. Acayreie+. taooeti00enmsooenedtsigssrsdardaofl.OSsadTPf.7%wdmpassama Trouts thaDbela+reed-iL%cmp6wLoQocaonroavoiddamage. Tcw?aosybo,cimgmoube BANNING, CA. 92220 court chards an cosums"ariy absa►\od b> MV4 aeata "I and seffinm chards ass cater used when enacting wmacs (sac BWT•76 for TPI mcon mcndasices Bracing "we m drawing aian+dyabasajcram M.daic%&m mv.e=foGcvaos.DcsiyaaasvipUtatadcgwtcdain.yc iswnuistbocYfia;anthe meaber&aip wdy.Itisam rind toIatcrsl)"4baacuywovuaU w a'Pcprwidtdtjbp=vcsboadiag doi$a bracing which is dace by orhets. Referw JILT 20 (WI) fw mefty oc ded tnus is fie w iod oi&A crow lis-upossbu Y is auumd ba ovuaU buildiag design. ha,adtag an4cr%cuoa. Dcsip Wadi sho dd not be applied Weil shuChis4 and bracilS ue eomplas. s . E R- 1 0- 9 3 F R I 1 5 1 3 C O U V.I S E N G I N E E R I N C R_ F 0 1 o rT /[-r Z- , G 0 U V I S NEWPORT BEACH • September 10, 1993 Harlan Lee and Associates 78-200 Calle Fortuna La quints, CA 92253 Attn: Randy Wessman Re: The Cove Missing Holdown G.E. Job No. 11415 Dear Randy: E N G I N E E R I N SAN DIEGO c PALM SPRING:. Pursuant to your request regarding the above captioned project, and per our phone conversation on September 9, 1993, we submit the following: At rear of the garage, apply a Simpson HD5A.holdown with a 3/4" diameter.Hilti "HVA" bolt in lieu of the missing holdown strap. For more information see the attached detail "A". Note: Please verify the above with the building department prior to construction. If you have any questions, please. do not hesitate to contact this. office. Sincerely, GOUVIS ENGIkEERING Nicholas A. Gouvis Q .OfESS/pH . President p 5 A I/ NAG: RF: jf attachment 11415253.FFL q , c9 No. C 12360 m C4 ti Exp. 3/31/97 CIV0. OF CAt F G O U v IS ENG I NEER I "C; P_ S P_ 2 _ _.. GOU•VI5 ENGINEERING J•N•G-I11-A Oat* C - lb • q' Client aK 1a L. . 1. 44 POST. U.N.O. 2 SIMPSON N 3. HILT! HVA ANCHOR=44 bj —, 4. Ha PER SIMPSON REQUIREMENTS RES. FT'G TO GARAGE i1 NON—MONOLJTHIC POUR NOTES: ALL BOLTS TO CONCRETE SHAD. BE. NILTI HVA. ANCHORS VATH HEA RAN ANI, INSTALLED PER ICIBO #4016 AND MJ, IUFAC— TURER'S RECOMMENDATIONS OR API,,1OVED EQUAL.' CONCRETE STRENGTH f c - 2000 ps;i MIN. ADEQUATE SIZE WASHER REQUIRED WHEN ANCHOR BOLT SIZE IS SMALLER THAN HOLE IN HOLDOWN. CONTRACTOR SHALL SPECIFY OVERALL LENGTH CF ANCHOR. WHEN INSTALLING HVA ANCHORS SPECIAL INSPECTION IS REOUIRED. MISSING CAPACITY OF RX = A BARRYA.BERKUS A.I.A. August 16, 1993 Harlan Lee & Associates 310 Washington boulevard Marina Del Rey, CA 90292 Attn: Randy Dear Randy: 5-3 - 7X- t7 2 Per our phone conversation, I would like to clarify the location of the footing omission described in the letter from Carl Schneider on August 12, 1993. 1. Due to the fact that the 3 -point bearing trusses have been redesigned as 2 -point bearing trusses, the footing running the length of the house dividing the LIVING/DINING areas from the SLEEPING areas may be omitted. (not required) If you have any further questions, please call. Sincerely, Barry A. Berkus, A.I.A. Scott Branch 223 E. De La Guerra Santa Barbara. CA 93101 805/963-8901 Fax: 805/966-6846 S ►i144r'!!r, vBARRY A. BERKUS`• * = . LIC. #C7733 i REN. 'mss -9%'•''••...._. ''.•QQ•e° jW It ' •a Outnta - .. 4M.) a; Lit UiTP . t)at/! it10' n I This 'Certificate issued pursuant to,the requirements of Section'306 of'the'Uniform.Bullding,, ' I I ► Co"de,certifying that at the time of issuance- this structure_ was in_ compliance with.the various. ordinances of the City regulating 'building construction or use. For the `following: 53-725• Avenida II I BUILDING ADDRESS ,Martinez .f = . j ti ,S • TUse j "Single le Famil• Dwellin ! i Classification'— g ' g Bldg. Permit No. ;} i It III i I 1 f 'Group R3 TYPe; Consfrucfion ' VN,, ' ire Ione Use Zone SR I ='La Quinta cove Home;" Inc. 310 Washington, :Ste. P214' Owner of Building Address, I I r • Santa `Monica Cit , CA 90292` _. -' - Y .A Lonnie, Day', Th By;../ 11 Build! ng. Official ' r ,F .. P09T IN A CON9pI000U9 PLAC£ , -- rM Zvi ,4 F,yPF .1.x,9 I (t of n uinta uttbtn anttun l I This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building' II' I Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: P BUILDING ADDRESS 53-725 Martinez j I( Use Classification RFT) Bldg. Permit No. 11046 ► 1 ; Group R1 Type Construction VN Fre Zone Use Zone SH I i ! i ► La Quinta Cove 'Home, Inc 53-725 Martinez Owner of Building Address I II I .: LQ CA . LONNIE DAY City_ j l B Dote • 1 2 — 2 1 — gI Building Official POST IN A CONSPICUOUS PLACE -