9804-023 (PAT)54030 Avenida Martinez
9804-023
„ . LICENSED CONTRACTOR DECLARATION
hereby affirm under penalty of perjury that I am licensed under provisions of
;hapter 9 (commencing with Section 7000) of Division 3 of the Business and
r%rofessionals Code, and my License is in full force and effect.
_icense # Lic. Class Exp. Date
,Date { `- 'Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
GOLDF,t4 EAGLE NWC 3=1741-03
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation,provisionsyof Section 3700 of the Labor
Code, I shall forthwith comply with tfi✓se p ovisionsy; '
pate: / 7 a Applicant}1 '' ”
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
-for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnity
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authoris .e representatives of rs City to enter upon
the above-mentioned property fotrinspectio /purpose$.
gnature (Owner/Agent) Date
f
BUILDINGPERMIT PERMIT# CONTROL#.
DATE VALUATION LOT TRACT
7 013
! YJS1y'1; .2C1
1
JOB SITE APN
ADDRESS 54-030AV.ENNIDA rd"TII.EZ
OWNER CONTRACTOR / DESIGNER / ENGINEER
MARX 'CUV11,I.1, SUTII OSF C'C;tt'POli.saTION
PALM DWSPIff CA 4220
. (7€t't11177 YI `23taff 37 f
y
USE OF PERMIT t
PAN)
l )
t44 S.F. lrA,r MC i PATIO COVTsR
APR 0 1 1998
PO(tC1131A110 ;t,; a CITY OF LA QUINTA
L•' 1
Ui8MIT i+EE, SUMMARY
i'[aAIN r_".EW.CK, 101-000-434-319
CONXMICTft7Af FEY- 10140-4133-000 %411 AD
S: ttl.)NIG INICITION FEE - 101-000-241-0W S.50
`I1>a-1Y.iT LCON rr i. CTION AND PIAN t_ tt'C. K ' $7,179,
USS PRETAID ITE?S p0.Ot1
'.1'4YfAl" 1'.FHN11'F'P1eta S 101F; NOW I S74.7:
RECEIPT I DATE t I BY I DATE FINALED I INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
_
Final /3LlPOOLS
BLOCKWALL APPRO ALS
- SPAS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
Q.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring r
Fbctures 3
Main Service ;
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
0tility Notice (Perm)
COMMENTS:
RAFTER SIZE AND SPACING—
/!SEE ROGF-NG VOTE GJ ErERSE)
ROOF PITCH
All
1
CONTINUOUS LEDGER
(SAME SIZE AS RAFTERS)
CN
H DR SIZE
W
/ i/ i
L % J
RAFTER SPAN: `_O
O.H. a
/ O
OVERALL LENGTH: D 1.
, N a
REAR SETBACK
/ 1
2000 P.S.I CONCRETE FINISH GRADE
L_J
—'T'AND 'L• STRAPS
6"x6"xl' xI/8" WITH
/ (4) 16a NAILS OR BOLT
POST SPACING:__I_
O.H
OVERALL LENGTH:__-
POST SIZE: -1L_- 0w
SIDE SETBACK (4"xd" MIN.)
FINISH GRADE MIN. 17'x12" FOOTING I I
L -J 12" BELOW GRADE L -J
PROVIDE 1" CLEARANCE
BETWEEN POST AND
,. .
CONCRETE
NOTE:
OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA
VIA ONE 1/4" x S" LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL.
3/8" x 5" LAG SCREWS INTO STUDS AT 16" O.C.
— y
.t CONTINUOUS LEDGER l_l/
JOIST HANGER OR SOLID BLOCKING
NAIL RAFTER TO BLOCKING
BUILDING DEPARTMENT APPROVAL BELOW
CIT° OF LA CSU I MTA
BUIL Ili SAFETY DEI ARTMENT
F Cay DDI 11.O ALl-1'
E 'tet F )R CONT ,UUP! 0,,\,!
_ = PER
AND ALL APPLICABLE CODES
DATELl L BY zi __
- -
U—STRAP OR AN(
NON—CORROSIVE
(4)— 1.6d NAILS
OR BOLT
W
U
Z
w
U
Z
i
U—STRAP OR ANGLE
(4)- 16d NAILS
OR BOLT
PROVIDE 1" CLEARANCE
BETWEEN POST AND
CONCRETE —L
ANCHOR BOLT (EMBED —
7" MIN. INTO CONCRETE)
TYPICAL PATIO COVER
DATE OF APPLICATION
OWNER'S NAME
STREET ADDRESS
CITY. ST ZIP
TELEPHONE
H.O.A. APPROVAL
r
por
v v u
RAFTER SPAN TABLE % /< O
GRADING RULES 3 `-' G' C-) / _- F
PS 20-70
(FEET & INCHES) 00A ? 00 A, ? a5 v P
Z0, 0
2x4
16" O.C.
24" "
10'-6"
9'-6"
7'-3"
8'-9"
8'-6" 8'-0" 6'-0"
7'-3"
FIR NO. 1
DOUGLAS FIR
2x6
16" O.C.
24" "
32" "
15'-T
14,-0"
1m-9"
13'-0"
12'-6" 11'-6" 8'-9"
10'-6"
10'-0" 1 8'-6" ' N/A_
N/A
8'-0"
4x6
2x8
16" O.C.
24"
32"
18'-0"'
17'-0"
13'-6"
16'-0"
15'-6" 14'-6" 11'-0"
13'-0"
13'-0" 11'-6" N A
N/A
17'-0"
4x`12
NOTE:
32" O.C. SPANS ARE ALLOWABLE FOR OPEN LATTICE
PATIO COVERS ONLY.
LATTICE
ROOF
BUILT-UP
ROOF
HEADERS
HEADERS
DOUGLAS
FIR NO. 1
DOUGLAS FIR
NO. 1
SIZE
SPAN
SIZE
SPAN
4x4
5'-0"
4x4
4'-0"
4x6
8'-0"
4x6
6'-0"
4x8
11'-0"
4x8
8'-0"
4x10
14'-0"
4x10
10'-0"
4x`12
17'-0"
4x`12
12'-0"
6x8
14'-0"
6x8
12'-0"
6x10
17'-0"
6x10
14'-0"
ALL. CONSTRUCTION SHALL CONFORM
TO THE PROVISIONS OF THE 1994
UNIFORM BUILDING CODE.
ROOFING NOTES:
A. BUILT-UP, ROLLED ROOF: SLOPE TO DRAIN.
B. ROCK ROOF: 3/12 MAXIMUM PITCH.