SFD (13-0625)54075 Avenida Martinez
13-0625
P.O. BOX 1504 T4&t
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 13-00000625
Property Address: 54075 AVENIDA MARTINEZ
APN: 774-221-017-5 -000000-
Application description: DWELLING - SINGLE FAMILY DETACHED
Property Zoning: COVE RESIDENTIAL
Application valuation: 120949
Applicant:
Architect or Engineer:
N _Gt_ -
LICENSED CON CTOR'S RATION
I hereby affirm under penalty of a ry that am license un er provi ons o Chapter 9 (commencing with
Section 7000) of Division 3 of th 8 iness d Profess ovals Code, nd m License is in full force and effect.
License Class: 13 License 27199
Dat r —5 '`• Contract r f
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement'that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001.:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ ) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: n
LQPERMIT
Owner:
RW REAL ESTATE
P.O. BOX 447
SANTA FE SPRINGS, CA 90670
(760)619-7611
Contractor:
CORONEL ENTERPRISE
42760 MADIO STREET
INDIO, CA 92201
(760)775-1234
Lic. No.: 727199
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
AUG 0.;' 2013
CITY OF LA QUINTA
FINANCE DEPT.
Date: 8/05/13
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
Ift issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
•'" Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 9033452-2012
I certify that, in the performance of the work for w is permit is issued, I shall not employ any
person in an m ner sLhall
o ubject the orkers' compensation laws of California,
and agree tha if shous ject tote wor rs' compensation provisions of Section
3700 of the La or odrtith corn ly w' those provisions.
Dat e:"1 'S- ( Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS J$1 00,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessatio0ofrk for 180 days will subject
permit to cancellation.
I certify that I have read this application and stat th t the bove infor tion isI agree to comply with all
city and county ordinances and state laws relatin to uildi constr coon, anduthorize representatives
of this county to enter upon the above-mentioned o erty f r insp ion purp
Dat$ -5-13 Signature (Applicant or Agen
Application Number . . . . . 13-00000625
------ Structure Information 1,834SF DWELLING/VB/RES-3/CLASS
A-FR/13D-----
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
3.00
FIRE SPRINKLERS 13D
GARAGE SQ FTG
459.00
PATIO SQ FTG
210.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
1834.00
Permit . . .
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
713.00 Plan Check Fee
463.45
Issue Date . . . .
Valuation . . . .
120592
Expiration Date
1/11/14
Qty Unit Charge
Per
Extension
BASE FEE
639.50
21.00 3.5000
----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
73.50
Permit . . .
ELEC-NEW RESIDENTIAL
Additional desc . .
Permit Fee . . . .
103.37 Plan Check Fee
25.84
Issue Date . . . .
Valuation . . . .
0
Expiration Date
1/11/14
Qty Unit Charge
Per
Extension
BASE FEE
15.00
.00 .0300
ELEC NEW RES - MULTI FAMILY
.00
1834.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
64.19
459.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
9.18
1.00 15.0000
----------------------------------------------------------------------------
EA ELEC TEMPORARY POWER POLE
15.00
Permit . . .
GRADING PERMIT
Additional desc . .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
1/11/14
Qty Unit Charge
Per
Extension
BASE FEE
15.00
.00 9.0000
----------------------------------------------------------------------------
THOU GRADING 1001-10,000
.00
Permit . . . . . . MECHANICAL
LQPERMIT
I
LQPERMIT
Application Number .
. . . . 13-00000625
Permit
. . . .
MECHANICAL
BASE FEE
15.00
1 Additional
desc . .
PLB FIXTURE
78.00
1.00
Permit Fee
PLB BUILDING SEWER
84.00
Plan Check Fee
21.00
Issue Date
. . . .
1.00
Valuation . . . .
0
Expiration
Date . .
1/11/14
PLB WATER INST/ALT/REP
3.00
Qty Unit Charge
Per
PLB LAWN SPRINKLER SYSTEM
Extension
1.00
.7500 EA
BASE
FEE
15.00
1.00
9.0000
EA MECH
FURNACE <=100K
9.00
1.00
4.5000
EA MECH
VENT INST/ DUCT ALT
4.50
.00
9.0000
EA MECH
B/C <=3HP/100K BTU
.00
1:00
16.5000
EA _MECH
B/C >3.-15HP/>100K-500KBTU
16.50
5.00
6.5000
EA MECH
VENT FAN
32.50
1.00
---=-----------------------------------------------------=------------------
6.5000
EA MECH
EXHAUST HOOD
6.50
Permit . .
Additional desc .
Permit Fee . . .
Issue Date .
Expiration Date .
PLUMBING
143.25
Plan Check Fee . . 35.81
Valuation . . . . 0
Qty
Unit Charge Per
Extension
BASE FEE
15.00
13.00
6.0000 EA
PLB FIXTURE
78.00
1.00
15.0000 EA
PLB BUILDING SEWER
15.00
.00
6.0000 EA
PLB ROOF DRAIN
.00
1.00
7.5000 EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000 EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000 EA
PLB LAWN SPRINKLER SYSTEM
9:00
1.00
.7500 EA
PLB GAS PIPE >=5
.75.
1.00
15.0000 EA
PLB GAS METER
15.00
----------------------------------------------------------------------------
Special-Notes
and Comments
1,834SF
DWELLING/VB/RES-3/CLASS A/13D
[ENGINEERED] THIS PERMIT DOES NOT
INCLUDE
BLOCK WALLS, POOL,
SPA OR
DRIVEWAY APPROACH. 2010 CALIFORNIA
BUILDING CODES.
----------------------------------------------------------------------------
Other Fees . . . . . . . .
. BLDG STDS ADMIN (SB1473)
5.00
DIF COMMUNITY CENTERS -RES
129.00
DIF CIVIC CENTER - RES
942.00
ENERGY REVIEW FEE
46.35
DIF FIRE PROTECTION -RES
433.00
GRADING PLAN CHECK FEE
15.00
DIF LIBRARIES - RES
344.00
MULTI -SPECIES (MSHCP) FEE
531.00
Application Number . . . . . 13-00000625
--------------'-------------------------------------------------------------
Other Fees . . .
. . ... . .
DIF PARK MAINT FAC - RES
40.00
DIF PARKS/REC - RES
2048.00
COVE PRECISE PLAN FEE
100.00
STRONG MOTION (SMI) - RES
12.06
TUMF: RESIDENTIAL
1837.44
DIF STREET MAINT FAC -RES
116.00
DIF TRANSPORTATION - RES
2842.00
Fee summary
Charged
Paid Credited
----------
Due
-----------------
Permit Fee Total
_: --------
1058.62
---------- ----------
.00 .00
1058.62
Plan Check Total
546.10
250.00 .00
296.10
Other Fee Total
9440.85
.00 .00
9440.85
Grand Total
11045.57
250.00 .00
10795.57
LQPERMIT
\ uutii
P.O. BOX 1504
Building `Q-1 c {\ , 1 UINT CE CALIFORNIATAMPIO
Address J t ' _ ' ` •"` -Z OUINTA, CAORNIA 92253
Address r > y \-kk`l
,j .—k `i A
\_ a (. o. M 1\11-1 a 5
Ci Tel.
Zipip 7CO -r? 7S -\aZ
State Lic., City
^-7
& Classif. l t " Lic. #
Arch., Engr., \
Designer
Address Tel.
C `\ Z State
.a23 C Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the Provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
01, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. If, however, the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of safe).
0I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law)
131 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑Copy is filed with the city. ❑Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person In any manner so as to become subject to Workers' Compensation Laws of California.
Date Owner
NOTICE TO APPLICANT It, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
APPLICATION ONLY
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number _7 -74 --SDC- o` \-7
Legal Description \,5\
`
Project Description J `✓ '
Sq. Ft. No.
Size Stories
New 0( Add ❑ Alter O
Estimated Valuation
No. Dw.
Repair ❑ Demolition ❑
PERMIT AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
ti el
TOTAL MAY 2 o 20 13
CONTACT INFORMATI
NAME: CIN OF LA (dTA
PHONE: FINANCE DgEt--i
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line —
Rear Setback from Rear Prop. Line _
Side Street Setback from Center Line
Side Setback from Property Line —
FINAL DATE
Issued by:
Validated by: —
Validation:
YELLOW = APPLICANT
INSPECTOR
Date Permit
PINK = FINANCE
Date
8/5/13
No.
31761.
Owner
R.W. Real Estate
Address
54075 Avenida Martinez
City
La Quinta Zip 92253
Tract #
Type
Single Family Residence
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
No. of Units
Lot # No. Street S.F. Lot # No.
Unit 1 54075 Avenida Martinez 1834 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
IED
A3
11V11`o
BERMUDA DUNES r
RANCHO MIRAGE d
`I INDIAN WELLS
PALM DESERT y
LA QUINTA
INDIO
Qy
O
774-221-017
La Quinta
1
Street
S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Addition of Sq. Ft. to New Construction
This certifies that school facility fees imposed pursuant to
in the amount of $3.20 X 1,834 S.F. or $5,868.80 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Rabobank, N.A./Ish Cornell Check No. 008004448
Bank Name/Recipient of Certificate Telephone 760-775-1234
Funding Residential
By Dr. Gary Rutherford
Superintendent
Fee collected /exempted by Espe Lara Payment Recd
$5,868.80 ,?yer1l1no r
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
T-vf
"
Building & Safety Department
78-495 Calle Tampico
La Quinta, CA 92253
(760) 777-7012 voice - (760) 777-7011 fax
To: Greg Butler, Building Official To: PD: May 22, 2013
From: Les Johnson, Community Development Director Due date: ASAP
Permit #13-625 Status: 1ST Review
Building Plans Approval
(This is an approval to issue a Building Permit)
CVMSHCP Applicable Fee N/A.
The Planning Department has reviewed the Building Plans for the following project:
Description: Cove House
Address or general location: 54075 Avenida Martinez APN: 774-221-017
Applicant Contact: Coronel Enterprises ph: 760-775-1234
The Planning Department finds that:
❑ ..these Building Plans do not require Planning Department approval.
..these Building Plans are approved by the Planning Department.
❑ ...these Building Plans require corrections. Please forward a copy -of the attached
corrections to the applicant. When the corrections are made please return them
to the Planning Department for review.
` w
Les Johns , Community Development Director Date
NOTE: EASE RETURN PLANSWITH GREEN SHEET TO THE BUILDING AND
SAFETY DEPARTMENT
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Arsanto Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/16/2013
Project Address
54-075 Avenda Martinez La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,834
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5
Status
Wall Wood Framed
R-19 863
New
Door Opaque Door
None 20
New
Roof Wood Framed Attic
R-38 1,834 Radiant Barrier
New
Slab Unheated Slab -on -Grade
None 1,834 Perim = 80'
New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades
Status
Front (E) 52.0 0.500
0.45 10.0 none Bug Screen
New
Front (E) 6.0 0.500
0.45 2.0 none Bug Screen
New
Right (N) 40.0 0.500
0.45 2.0 none Bug Screen
New
Rear (W) 71.5 0.500
0.45 2.0 none Bug Screen
New
Left (S) 96.0 0.500
0.45 2.0 none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
Whole House Ducted
Ducted Attic, Ceiling Ins, vented 8.0
New
WATER HEATING --....
Ot . Type Gallons Min. Eff Distribution i V (-)I 1 at
1 Small Gas 50
0.62 All Pipes ins BUILDI G SAFETY
r,e
APP
FOR1
ION
Ene Pro 5.1 6 Ene Soft User Number: 2655 RunCode: 2013-05-16716:44:4.9 ID'
Pa e 3 f 12
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF-1 R
Project Name
Arsanto Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/16/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 600.0 ft2 Exposed Slab Floor, 3.500" thick at Whole House
HIGH MASS Design - Verify Thermal Mass: 1,234.0 ft2 Covered Slab Floor, 3.500" thick at Whole House
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
The Cooling System Amana DMS90905DXA includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Whole House includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
CITY OF LA QLANT,8
UILUINU ��
& SAFETY DEPT.`
�r r r- U
FOR CON,':;VRI r
Ene Pro 5.1 b Ener Soft User Number. 2655 RunCode: 2013-05-16716:44:491 ID: a e 4 df 12
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Arsanto Residence
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
5/16/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 1.97 2.18 -0.21
Space Cooling 45.20 42.89 2.31
Fans 9.20 12.73 -3.53
Domestic Hot Water 17.17 15.54 1.63
Pumps 0.00 0.00 0.00
Totals 73.54 73.35 0.19
Percent Better Than Standard: 0.3%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 220 58
Fuel Available at Site: Natural Gas (S) 264 96
Raised Floor Area: 0 (w) 400 72
Slab on Grade Area: 1,834 (N) 264 40
Average Ceiling Height: 8.0 Roof 1,834 0
Fenestration Average U-Factor: 0.50 TOTAL: 266
Average SHGC: 0.45 Fenestration/CFA Ratio: 14.5%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
5/1 2013
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si ne Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per B%siness & Professions Code)
Company S / r`r "`V4.0 57 .(// ) C1 nt'
/
Address `' Name l u(U 3
(►B
City/State/Zip Phone C O 6) 360— k S SAd Lr'e se # PT-D e
CONS-ARuc,,Tlnbl
Ener Pro 5.1 by Ener Soft User Number: 2655 Run Code: 2013-05-16716:44:491 /D: ,,Page 5 , f 12
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Arsanto Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/16/2013
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation
Factor Cavity-----Fxterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Wall
142
0.074 R-19
90
90 New 4.3.1-A5
Whole House
Door
20
0.500 None
90
90 New 4.5.1-A4
Whole House
Wall
224
0.074 R-19
0
90 New 4.3.1-A5
Whole House
Wall
329
0.074 R-19
270
90 New 4.3.1-A5
Whole House
Wall
168
0.074 R-19
180
90 New 4.3.1-A5
Whole House
Roof
1,834
0.025 R-38
90
0 New 4.2.1-A21
Whole House
Slab
600
0.730 None
0
180 New 4.4.7-A1
Whole House
Slab
1,234
0.730 None
0
180 New 4.4.7-A1
Whole House
FENESTRATION SURFACE DETAILS
ID
Type
Area Ll -Factor'
SHGCz
Azm Status Glazing Type
Location/Comments
1
Window
40.0 0.500 NFRC
0.45 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
2
Window
12.0 0.500 NFRC
0.45 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
3
Window
6.0 0.500 NFRC
0.45 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
4
Window
16.0 0.500 NFRC
0.45 NFRC 0 New
IWC 6200 Alum/Low-E
Whole House
5
Window
4.0 0.500 NFRC
0.45 NFRC 0 New
IWC 6200 Alum/Low-E
Whole House
6
Window
20.0 0.500 NFRC
0.45 NFRC 0 New
IWC 6200 Alum/Low-E
Whole House
7
Window
6.0 0.500 NFRC
0.45 NFRC 270 New
IWC 6200 Alum/Low-E
Whole House
8
Window
13.5 0.500 NFRC
0.45 NFRC 270 New
IWC 6200 Alum/Low-E
Whole House
9
Window
40.0 0.500 NFRC
0.45 NFRC 270 New
IWC 6200 Alum/Low-E
Whole House
10
Window
12.0 0.500 NFRC
0.45 NFRC 270 New
IWC 6200 Alum/Low-E
Whole House
11
JWIndow
8.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
12
Window
4.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
13
Window
8.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
14
Window
4.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
15
Window
4.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
16
Window
4.0 0.500 NFRC
0.45 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat Wd
Ove hang Left Fin
Len I H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
6.8 6.0 10.0 0.1
10.0 10.0
2
Bug Screen
0.76
2.0 6.0 10.0 0.1
10.0 10.0
3
Bug Screen
0.76
2.0 3.0 2.0 0.1
2.0 2.0
4
Bug Screen
0.76
4.0 4.0 2.0 0.1
2.0 2.0
5
Bug Screen
0.76
1.0 4.0 2.0 0.1
2.0 2.0
6
Bug Screen
0.76
4.0 5.0 2.0 0.1
2.0 2.0
7
Bug Screen
0.76
3.01 2.0 2.01 0.1
2.0 2.0
8
Bug Screen
0.76
4.51 3.0 2.0 0.1
2.0 2.0
9
Bug Screen
0.76
6.8 6.0 2.0 0.1
2.0 2.0
10
Bug Screen
0.76
2.0 6.0 2.0 0.1
2.0 2.0
11
Buq Screen
0.76
4.0 2.0 2.0 0.1
2.0 2.0
12
Bug Screen
0.76
2.0 2.0 2.0 0.1
2.0 2.0
13
Bug Screen
0.76
4.0 2.0 2.0 0.1
2.01 2.01
14
Bug Screen
0.76
2.0 2.0 2.0 0.1
2.01 2.0 I
15
JBug Screen
1 0.761
27OF 2.0 2.0 0.1
.01 2.0
16
]Bug Screen
1 0.761
2.01 2.0 101 1
2.01 2.0, 3
& 13F -
A -0PROVED
Ener
Pro 5.1 by Ener Soft User Number. 2655
RunCode: 2013-05-16T16:44:49 ( ID:
f V e 6 of ,
E
DATE B
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF-1 R
Project Name
Arsanto Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/16/2013
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
LI-Factor'
SHGC
Azm Status Glazing Type Location/Comments
17 Window 4.0
0.500 1 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Mole House
18 Window 12.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Mole House
19 Window 12.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House
20 Window 12.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House
21 Window 6.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E WNhole House
22 Window 6.0
0.500 NFRC
0.45 NFRC 1801 New IWC 6200 Alum/Low-E Whole House
23 Window 6.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House
24 Window 6.0
0.500 NFRC
0.45 NFRC 180 New IWC 6200 Alum/Low-E Whole House
(1) U-Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
SHGC
Window
H t Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt I RExt Dist Len H t Dist I Len H t
17 Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
18 Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
19 Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
20 Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
21 Bug Screen
0.76
2.0 3.0 2.0 0.1 2.0 2.0
22 Bug Screen
0.761
2.0 3.0 2.0 0.1 2.0 2.0
23 Bug Screen
0.761
2.0 3.0 2.0 0.1 2.0 2.0
24 Bug Screen
0.76
2.0 3.0 2.0 0.1 2.0 2.0
P, w r 1
,u t H _ c
APP
ROVED
Fnrt nn s • 1
Ener Pro 5.1 by Ener Soft
User Number: 2655 RunCode: 2013-05-16716:44.49 ID: "" ' uV 0--e 7 of 12
DATE 2/
_
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Arsanto Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1 5/16/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area f
New Existinq Altered Removed Volume Year Built
Whole House Whole House
1,834
14,672
Totals 1 1,834 0 01 0
HVAC SYSTEMS
System Name Q!y. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Whole House 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Coolinq Duct Location R -Value
Ducts
Tested? Status
Whole House Ducted
Ducted Attic, Ceiling Ins, vented 8.0
m New
11
❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A. 0. SMITH FPS -50-224
1
Small Gas
All Pipes Ins
43,000
50
0.62
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM PIPING
Control
Hot Water Piping Length
ft
o
v
a —
stea- ame
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
—
❑ p
•
rr
A00
-A
iRUC
low
EnergyPro 5.1 by Ener Soft User Number: 2655
RunCode: 2013-05-16T16: 4:49 ID:
Paryk 8 of 7
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Arsanto Residence
5/16/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all 'oints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinq sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 50(VA: Insulation is protected from damage, including that due to sunli ht mist , e ent-Fnaipteaaace and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines include a ap,o r ar&a cJo d,griti e y in
rr%.oris
conditioned space. V(lJ 1 W j
§150(i)4: Solar water -heating systems and/or collectors are certified by the Sola Ratin "erhrfic tiorFFo'Fp ra'tiDEP
VED
FOR CON ,
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-16718:44:49 1 ge 9 of 12
DATE _J // // Z BY ),j
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name
Date
Arsanto Residence
5/16/2013
§150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150 k 2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw-base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPR V
EnergyPro 5.1 by EnergySoft User Number: 2655 Run Code: 2013-05-16T16:44'49 r /D: S UC ( Page 0 of 12
I DATE
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Arsanto Residence
5/16/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with 150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
F LA QUINTA
& SqFRp
E
EDEPT.ONST D
UCTION
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-05-16T16:44 SDA I Page 1 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Arsanto Residence
Date
5/16/2013
System Name
Whole House
Floor Area
1,834
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
784
0
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 70,000
18,778
1,945 493
18,149
Total Output Btuh 70,000
0
Output Btuh/s ft 38.2
1,084
892
Cooling System
o
0
Output perSystem 58,000
0
0 0
0
Total Output Btuh 58,000
0
1,9451
0
Total Output Tons 4.8
1 1,084
892
Total Output Btuh/s ft 31.6
Total Output s ft/Ton 379.4
1 20,946
19,933
Air System
CFM perSystem
2,055
HVAC EQUIPMENT SELECTION
Airflow cfm
2,055
Amana DMS90905DXA
43,919 5,771
70,000
Airflow cfm/s ft
1.12
Airflow cfm/Ton
425.2
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
43,919 5,771
Aug 3 PM
70,000
Outside Air cfmis ft 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF
Outside Air O
0 cfm Supply Fan
2,055 cfm
70 OF
70 OF 105 OF
Heating Coil
105 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 78 / 63
Outside Air
0 cfm
78!63°F
OF 78 / 63 OF 55 / 54 OF
Supply Fan Cooling Coil
2,055 cfm
- I I I
-
55 / 54 OF
C
jT:Y2. OF OM gg
BUILDING & AF YT6 F
APPR ` r
FOR C nt 9QED
EnergyPro 5.1 by EnergySoff User Number: 2655 RunCode: 2013-05-16716:44:49 ID: r h f Page 1 0f121
DEC/12/20130HU 05.4e FM Coronel Enterprises FAX NI-.7607755353 P.IDG,2
FFIRO
Er4r,IXSEILING, I...
City of La Quinta
Engineering/Building Dept.
78-495 Calle Tampico
La Quinta, CA 92253
P.O. 130x 12980
Palm Desert, CA 92255
(780) 346-8015
(760) 346-2548 Fax
www.feiro.net
Dec. 5, 2013
Re: Lot 5, Block 297, Unit-#27 Santa Carmelita at Vale
APN: 774-221-0117
This le4et will seine to state That we have field checked the finished floor
elevations for the a' bo ie project and found them tv be
Finished Floor �'I03:4$"(assumed eleu0161)
Top 6f'curb at center •ofike.lot 160:2l A;
"if you have any gpestions, please call meat 345=$015.
Sincerely
7. ofE�
W.
James D. Feiro a�' ®•
Vice 'resident �r
ri~ No. ic 24 t 76
RCE 24176
JDF/Inf OPCA � .� %
cc: Coronel Construction
. . . . . . . . . . . . . . . . . . . . . . . . . . .
RSA 5TR1 UCT UH I L EJ �G ` Z 1
77570 Springfield Lane, Suite "D" Phone: (760) 360-9998
Palm Desert, CA 92211 Fax: (760) 360-9903
January 23, 2014
City of La Quinta
Building & Safety Department
Project Address: RW Real Estate, Inc.
54-075 Avenida Martinez
La Quinta, CA
To whom it may concern:
The project mentioned above would like to replace simpson HDU2 holdown with USP structural connector
PHD2A. Based on the attached USP data sheet along with IAPMO Evaluation Report 40200 (Valid through February
2014) and City of Los Angeles Research Report #RR25954—CSI#06 05 23(Valid through May 2014) and to the best
of our knowledge & experience, the replacement of HDU2 with PHD2A should be permitted. The maximum tension
load applied for this holdown is 1,492 lbs. The allowable tension load for simpson HDU2 is approx. 3,075 lbs and
USP connector PHD2A allowable tension load is approx. 3,215 lbs (Values obtained per manufacturer specification,
see attached sheets). The USP connector is stronger than simpson holdown required and in addition can withstand
twice the amount of the apllied load. This replacement of holdown hardware should not affect structural integrity of
residence, and therefore, should be acceptable.
Please contact me should you need additional information regarding this letter.
Respectfully,
Reza Asgharpour, P.E.
2•
104
%.C6761 3 � E0
,a
CIVIC
OF
RECENED
JAN 2 4 2014
CITY OF ,.-A QUINTA
COMMUNITY DEVELOPMENT