Loading...
AR (06-0470)54470 Avenida Martinez 06-0470 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 06-00000470 54470 AVENIDA MARTINEZ 774 -254 -024 -ST -000000- ADDITION - RESIDFnTTTAT, COVE RESIDENTIAL 29515 Arc Tity/ 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ----------------- - -------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. L icense Ts- B LiicepsVNo.: 8280 t v ntractor. /I OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to ' construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the ` permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: II LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/22/06 Owner: BILLS RANDY C 54865 AVENIDA OBREGON LA QUINTA, CA 92253 Contractor: LEGACY HOMES P.O. BOX 696 LA QUINTA, CA 92253 (760)777-8317 Lic. No.: 778280 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. JQ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 13302-2005 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the wort ' compensation provisions of Section jj 3700 of he Labor Cod 11 forthwith coryr j rth o e provisions. ateJ OW . /f WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinance nd state laws relating to building construction, and hereby authorize representatives of this county to enter on the ab en Toned prWpeforpection purposes. Date Signatur tl: Application Number . . . . . 06-00000470 Permit . . . BUILDING PERMIT BASE FEE Additional desc . . EA PLB FIXTURE Permit Fee . . . . 284.50 Plan Check Fee 184.93 Issue Date . . . . EA Valuation 29515 Expiration Date 9/18/06 PLB WATER INST/ALT/REP Qty Unit Charge Per Extension BASE FEE 252.00 5.00 ---------------------------------------------------------------------------- 6.5000 THOU BLDG 25,001-50,000 32.50 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/18/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 ------------------------------7--------------------------------------------- 6.5000 EA MECH VENT FAN 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 33.06 Plan Check Fee 8.27 Issue Date . . . . Valuation' 0 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 15.00 516.00 ---------------------------------------------------------------------------- .0350 ELEC NEW RES - 1 OR 2 FAMILY 18.06 Permit . . . PLUMBING Additional desc . . . Permit Fee . . . . 67.50 Issue Date Expiration Date . . 9/18/06 Qty Unit Charge Per Plan Check Fee . Valuation . . . LQPERAIIT 16.88 0 Extension 15.00 24.00 15.00 7.50 3.00 BASE FEE 4.00 6.0000 EA PLB FIXTURE 1.00 15.0000 EA PLB BUILDING SEWER 1.00 7.5000 EA PLB WATER HEATER/VENT 1.00 3.0000 EA PLB WATER INST/ALT/REP LQPERAIIT 16.88 0 Extension 15.00 24.00 15.00 7.50 3.00 Application Number . . . . . 06-00000470 Permit . . . . PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 . ---------------------------------------------------------------------------- Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Issue Date . . . . Expiration Date . . 9/18/06 Plan Check Fee .00 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 516 SF. DETACHED CASITA ---------------------------------------------------------------------------- Other Fees . . . . . . ... . ENERGY REVIEW FEE 18.49 STRONG MOTION (SMI) - RES 2.80 Fee summary Charged ---------- Paid Credited --•---------------------------- Due ----------------- Permit Fee'Total 439.56 .00 .00 439.56 Plan Check Total 219.96 .00 .00 219.96 Other Fee Total 21.29 .00 .00 21.29 Grand Total 680.81 .00 .00 680.81 LQPERiYfIT STRUCTURAL DESIGN CALCULATIONS for Legacy Home Guest House TABLE OF CONTENTS Section 1 -- General Section 2 -- Gravity Load Analysis Section 3 -- Lateral Load Analysis CITY OF LA QUINTA BUILDING & SAFETY DEPT. Section 4 Connections -- APPROVED PPRO V ED FOR CONSTRUCTION DAIS;-' O C R S7 Prepared By: Satellite Offices: Concorde Consulting Group, Inc Concorde Consulting Group, Inc 3505 Camino Del Rio South, #350 4511 E Sunnydunes, # E San Diego, California 92108 Palm Springs, California Project No: 06-016 Revision 0 Dated: For: Review SECTION 1 --GENERAL (LOADS, CODES. MATERIALS AND SPECaFICATIONS) A. Gravity Loads Roof Dead Load Roof 8.psf Plywood 2.8 psf Framing 2.5 psf Misc 3.5 psf Insulat 1.5 psf Mech/E1 1.7 psf Subtotal 20 yof HENCE: Roof Dead Loads 20.00 psf Roof Live Loads 20.00 psf B. Lateral Loads -- SE%SMXC Seismic Design Base Shear (1997 UBC Section 1630.2.1) Soil Profile = Sb Zone Factor = 0.4 Seismic Coeff, Ca = 0.44 Na Near Source Na = 1 (Actual used is 1.1) Coefficient, R (1997 UBC Table 16-N) Steel OMRF/Masonry, R =4.5 Light bearing , = 5.5 (wood) Cantilevered C. = 2.2 Seismic Shear, V = (3.0 Ca*I/R)W _ (3.Ox0:44xl.1/R) W V shear walls = 0.264W (for wood) V cantilevered cols ="0.720 W(for TS Cols) V masonry walls = 0.352 W (for Masonry) Load divisor = 1.4 ASD Design V = (0.264/1.4) W = 0.19W "(Wood) ASD Design V (0.352/1.4) W = 0.25W(for Masonry) ASD Design V = (0.720/1.4) W = 0.51W(for TS Columns) .Z Ce Lateral Loads -- VXRD Wind Speed = 80 mph Basic Wind Pressuz 16.4 psf Exposure = C Factor, Ce = 1.13 Factor, Cq = 1.3 Factor, I = 1 Effective Wind Pressure gxCgxCexI = 16.4xl.13xl.3xl.0 24.09, say 24.0 psf De Code: 2001 CALIF BUXLDXNG CODE (1997 OBC CODE PARAMTERS) Eo Soils Parameters Provided by: Not Available q (allowable) 1000 psf Fe material Parameters Steel Structural Steel Shapes/P:ASTM A36 Structural Tubes ASTM A-500, Grade B Structural Pipes ASTM A-53, Grade B 0o Concrete Normal Weight f'c (28days) 2500 psi Masonry f'm 1500 psi K. Lumber Lumber Douglas Fir Larch # 1 X. BOLTS Typical High Strength J. WELD%NG Typical ASTM A-307 ASTM A-325 only when noted E-70XX electrodes 3 SECTION 2 -- GRAVITY LOAD ANALYSIS BEAM TAG INFORMATION IS SHOWN ON THE FRAMING PLAN PROVIDED •WITH PACKAGE Concorde Consulting Group, Inc. 3505 Camino Del Rio South, #350 San Diego, CA 92108 Legacy Home Guest House RB -1 Date: 1/22/06 BeamChek 2.2 Choice 4x 6 DF -L #1 BASE Fb = 1000 ADJ Fb = 1625 Conditions '91 NDS Min Bearing Area R1= 1.1 inz R2= 1.1 inz DL Defl<0.01 in. Data Attributes Actual Critical Status Ratio Values Adiustmerits Loads Beam Span 3.0 ft Reaction 1 697 # Reaction 1 LL 345 # Beam Wt per ft 4.68 # Reaction 2 697 # Reaction 2 LL 345 # Beam Weight 14 # Maximum V 697 # Max Moment 523'# Max V (Reduced) 484 # TL Max Defl L / 240 TL Actual Defl L/>1000 LL Max Defl L / 360 LL Actual Defl L />l 000 Section (in3) Shear (in2) TL Defl in LL Defl 17.65 19.25 0.01 _ <0.01 3.86 6.11 0.15 0.10 OK OK OK OK 22% 32% 7% 5% BeamChek has automatically added the beam self -weight into the calculations. Uniform TL: 460 =A Uniform LL: 230 Uniform Load A 0 Q R1 = 697 R2 = 697 SPAN = 3 FT Uniform and partial uniform loads are lbs per lineal ft. Fb (psi) Fv (psi) E (psi x mil) Fc -L (psi) Base Values 1000 95 1.7 625 Base Adjusted 1625 119 1.7 625 CF Size Factor . 1.300 Cd Duration 1.25 1.25 Cr Repetitive Ch Shear Stress Cm Wet Use BeamChek has automatically added the beam self -weight into the calculations. Uniform TL: 460 =A Uniform LL: 230 Uniform Load A 0 Q R1 = 697 R2 = 697 SPAN = 3 FT Uniform and partial uniform loads are lbs per lineal ft. ,Concorde Consulting Group, Inc. 3505 Camino Del Rio South, #350 San Diego, CA 92108 Legacy Home Guest House RB -2 Date: 1/22/06 BeamChek 2.2 Choice 4x 8 DF -L #1 BASE Fb = 1000 ADJ Fb = 1625 Conditions '91 NDS Min Bearing Area R1= 1.9 int R2= 1.9 int DL DO 0.03 in Data Attributes Actual Critical Status Ratio Values Adiustments Loads s Beam Span 6.0 ft Reaction 1 1218 # Reaction 1 LL 600 # Beam Wt per ft 6.17 # Reaction 2 1218 # Reaction 2 LL 600 # Bbam Weight 37 # Maximum V .1218 # Max Moment 1828'# Max V (Reduced) 973 # TL Max Defl L/240 TL Actual Defl - L/>1000 LL Max DO L/360 LL Actual Defl L / >1000 Section (in3) Shear int TL Defl in LL Def I' 30.66 25.38 0.06 0.03 13.50 12.29 0.30 0.20 OK OK OK OK 44% 48% 21% 15% BeamChek has automatically added the beam self -weight into the calculations. Uniform TL: 400 =A Uniform LL: 200 Uniform Load A 0 0 R1=1218 R2=1218 SPAN = 6 FT Uniform and partial uniform loads are lbs per lineal ft. I Fb (psi) Fv (psi) E (psi x mil) Fc -L (psi) Base Values 1000 95 1.7 625 Base Adjusted 1625 119 1.7 625 CF Size Factor 1.300 Cd Duration - 1.25 1.25 Cr Repetitive Ch Shear Stress Cm Wet Use BeamChek has automatically added the beam self -weight into the calculations. Uniform TL: 400 =A Uniform LL: 200 Uniform Load A 0 0 R1=1218 R2=1218 SPAN = 6 FT Uniform and partial uniform loads are lbs per lineal ft. I SECTION 3 -- LATERAL LOAD ANALYSIS (SEISMIC) ATERAL ANALYSIS -%x7TNTn Wind Speed = 80 mph Basic Wind Pressure: 16.4 psf Exposure = C Factor, Ce = 1.13 Factor, Cq = 1.3 Factor, I =1 Effective Wind Pressure gxCgxCexI = 16.4x1.13x1.3x1.0 = 24.09 use 24.0 psf SEISMIC (Note: Eh = V per calc's) Eh = (2.5 Ca/1.4 R)(WDL) = 0.19 WDL 'Divided by- 1.4 for Strength to A.S.D. Where: ZONE R CA N SEISMIC SOURCE: B 4 5.5 0.44 1.00 1 SOIL TYPE: So 1 STORY Vs= (RoofD.L.+ WallD.L )X 0.19 Vs= 5.7 p.s.L SUMMARY OF LATERAL DESIGN UTILIZES THE FOLLOWING FORMULAS Eh = 1/2(Abase)(Adepth)(VS) 5 = E/T.L. Overturning X'P.H. WIND GOVERNING LENGTHS L = (VW xH ;b) / Eh 1 Story Hh;b =13 VW X Hh;b = 312 L=33.5 ft. ANALYZE EACH SHEAR LINE PER PLAN FOR WORST CASE CONDITION (i.e. Wind or Seismic). DESIGN ACCORDINGLY. s war SUMMARY OF LATERAL DESIGN FOR EQ/WIND LOADS Grid Abase A depth V eq (psq , `7 wind (psf) Effective Plate Ht (f) EQ Load (lbs) Wind Load (lbs) Governing Lateral Load (Ibs) Shear Wall Length (f) Total Wall Length (ft) Unit Shear V l s) Gross Uplift in Lbs ype o Shear Wall Holdowns First Floor A. 12 12 5.7 24 10 410 720 720 7 7 103 1029 0 N/A B 36 20.5 -5.7 24 10 2103 2160 2160 5+5 10 216. 2160 1 HD2A C 24 20.5 5.7 24 10 1402 1440 1440 5.5 5.5 262 2618 2 HD2A D 21.5 21.5 5.7 24 10 1317 1290 1317 5 5 263 2635 2 HD2A 1 20.5 36 5.7 24 10 2103 1230 2103 1 4.5+14.5 19 111 1107 0 N/A 2 20.5 36 5.7 24 10 2103 1 1230 1 2103 112+5+6.51 23.5 90 1 895 1 0 1 N/A ME Redundancy Calculations Grid Width Length Area Vi ri A 12 12 72 410 4.3 sq rt area B 36 20.5 369 2103 22.3 22.3 40.69552 C 24 20.5 246 1402 14.9 0.222807 D 21.5 21.5 231 1317 14.0 rounded a=2-[20/riMAX (sqrt area)] 1 20.5 36 369 2103 22.3 0.22 40.7 -0.2336386 2 20.5 36 369 2103 22.3 1656 ' 9440 " SECTION 4 -- CONNECTIONS ALL WOOD CONNECTORS SHALL BE SIMPSON OR APPROVED EQUAL ALL ANCHOR BOLTS, HOLDDOWNS AND DOWELS SHALL BE IN PLACE AND .INSPECTED ACCORDING TO LOCAL BUILDING REGULATIONS CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR TRUSS COMPONENTS AND STEEL MEMBERS