AR (0110-089)78185 Masters Cir
0110-089
LICENSED CONTRACTOR DECLARATION
I h?reby affirm under penalty of perjury that I am licensed under provisions of
Chapter• 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
744091 23, 1°isfg'I ^I
Date,- /"'' Signature of Contractor-_< -*"' w
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section B&P.C. for this reason
Date _ Signature of Owner • `' -
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the, work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier STATE FUND Policy No. 229-00-0020 14
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Date: — Applicant
Warning: •F lata lure to secure Workers' Compensation n coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 drays from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
e
'I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agenq„—!, ''"'_ _ J Date
BUILDING PERMIT PERMIT#
0.1. 1O-Ci£
DATE VALUATION LOT86 TRACT 28867
JOB
ADDRESS 79.1 .°*`-.'d:!' %.I a .MRS IRWILE
APN
170-36,04v14.
OWNER
CONTRACTOR / DESIGNER / EN (NEER
X1151YER10 PROPER 11FIS LLC
:500. Vi''.9.'. h.'L EVE'' OINM `NT Ci)PP.
PC) 130X 1144
77899WOLF
LA 0%, 3&D CA 922S3
P Al:.A .IJ.ES k+.:I:t:I" CA 92260
(6A),V72.26x6 CTIAIN 593
USE OF PERMIT
AREA DiANG INI'3'1.,AL t^'ONU'f'FtUC! IN
I
6';US`l'OM PA JO C;KYN''+ ISR1yfa I, OD ZF
Evrin"YED C09.1.1 0,111 CONSTRUCTION
_PLAN (111-1XICK M. 101-000-4394-318 W,2A
CcrMS`MU t ,ION PKE 101 -000 -418 -OW $69.00
R ECI lk."s.CA11 RE 101-000-420-000 -000 V1,14
DEC U 5 70M
Ct( ipYOQFp L1AQ i`IWA V. E
TUT AL kIMMI r' F1MS DVE NOW
RECEIPT
DATE
7;1 E'
BY
DATE FINALED
P.2 :2 O z
INSPECTOR
;11
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts ;
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wali Insulation
Condensate Lines
Party Wali Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric ,
Underground Plbg. Test
Final I I
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I. .
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
Desert Sands Unified School District
47-950 Dune Palms Road
Notice: La Quinta, CA 92253
Document: Cannot Be Duplicated 760-771-8515
CERTIFICATE OF COMPLIANCE y
Date 12/4/01 APN # 770-360-014
No. 22727 x .. Jurisdiction La Quinta
owner NameSun Vista Development Permit #
No. 78-185 Street , Masters Circle Log #
City La Quinta Zip 92253 Study Area
Tract # Lot # Square Footage,, 61
Type of Development New Residential Addition No. of Units 1
Comments'
F
..: By
At the present time, the Desert Sands Unified School District does, not collect fees on garages/carports, covered
patios/walkways, residential additions'under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to.the following reason:
` Add. of Sq.. Ft. to New Construction
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to. ' Government Code 53080 in the amount of
2.05 X .61 or $ 125.05 the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may -now be•issued `
Fees Paid By. CC / 1 st Bank - Rob Capetz Teiepne'` 760=7,72-2626
w r
Name on the checkN'11,
r ,
Dr. Doris Wilson
t •
Superintendent
Fee collected/exemp ed by Annette Barlow Payment Received $125.05
Check No. 61825'
Signature
OTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
bove will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
ollect them on the District('s)(s') behalf, whichever is earlier.
Collector: 'Attach a copy of county or city plan check application form to district copy for all waivers.
cEmbossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
V 0 W4
qJ PO BOX 1 144 LA QUINTA CA 92253,1-1144 (760) 772-2626 FAX (760) 772-2302
un V
DEVELOPMENT CORPORATION
November 14, 2001
The City of Quinta
P.O. Box 1504
78-495 Calle Tampico
La Quinta, CA 92253
To Whom It May Concern:
Re: Lot 86 — Tract 28867
78-185 Masters Circle, La Quinta
We have not yet received HOA approval for the above Lot. We request that the City of
Laa-Quinta issue a .permit, as we have. met all of the city requirements to obtain -a permit.
Sincerely
or
Robert T. Ca
President ID
RJC/cz
fog
. Z
Summit Structural Engineering
2283 Fifth Street
La Verne, CA 91750
(909) 596-0842
August 14, 2001 Fax (909) 596-5187
Sun Vista Development, Inc.
P.O. BOX 1144
La Quinta, CA 92253
Attn: Rob Capetz
Subject: Addition at Master
Lot 86, Tradition
La Quinta CA
Dear Mr. Capetz;
Per your request we are providing additional engineering for an addition -at the master
bedroom/bath for Lot 86 at the Tradition. Please refer to the attached marked up
sketches/partial framing plans for more information'.
The slab extension should be doweled to the existing footing/slab at 24" o.c. with #4
rebar with 6" embedment' into the 6iMing slab per the attached detail "A". See the
partial foundation plan for locations of new 12" x-12" exterior footings (similar to the
original plans 1/SD1) and dowel to the existing footings per the attached detail "A".
New roof beams and framing are shown in red pen on the. architects revised "addition"
floor plan. Note that a small segment of. bearing wall is to be removed and replaced with
an offset 4x10 (rip to fit depth of roof joists). This 4x10 will hanger off of a trippler roof
joist (3-2x10 — rip to fit) which should be nailed together with 16d nails @ 8" o.c. The
back segment of framing can be filled with 2x10 roof joists at 24" o.c. which are ripped to
match the existing roof joists.
Note that there is a MSTA36 strap from the existing gluelam beam which is connects
the new offset 4x10 beam -to the beam in line with the steel_ column. _ Also -pay close
inspection of the hanger call -outs, as the standard LUS hangers do not have the proper.
capacity. Use.a HUS48 from the 410 to the tripple 2x10 roof joists, a HUS from the
tripple joists to the existing gluelam beam, and HUS26 hangers .from the existing roof
trusses to the offset 4x10.
If you have any questions, please give me a call.
Yours truly,
SUMMIT STRUCTURAL ENGINEERING
Benjamin Herbst, P.E.,
BH gAMy Documents\2000jobfiies\Sv-145\145_field2(addition).doc
Residential, Commercial, Industrial_ Land Development
w/ 14 •REBS _
12'O,C. tr/w r r. F,`•%:y
::, :i • Ar eOTTOht
'+ ' ', Y 666iii v • • .1 - , , F t'i t ` e - 1 r IS •.
S.
VNI
+' . ' • . ; ',+ 'PAp
.. AT EiffriOM•
Y ` j r R. r: '• yk+, T S I ^. .. 1i ~ • + '4R / 1• ♦. a IF
Ole
PAO F70- 14 PEW
I • 0.+0! T , .•P i ,Y.itl•rlY srr.•P b _ ' ' . { 1Ai f '+ , •• ,..
_ i ems. S0, CGA1C' - .y' • • : '. - ..+- •
f O• ..
NO
Ar SOMAO
` • a Ra
,;O' Spy cnvC -' g''o' f t.'c.
PAO Frcl W/ 14 RM
'12" 0. C, VWop
41 60 70
Eh'iCftON PAO 4 +
`` I 1''ry
i E'S d ;!h 'X • SIC zr.L Y 1-10: 9 '$Cf Ga i,E ,,1'L, 4•'®= '4'
f
AUG— 1 4—•0 1 J,TUE 1 ® :^010' • 3DBC; AFZ'CH Z`TECT'S I HC t?,. O$ ,
711
.—....... rr.rM wa.w fir+•++. rw.s - ! _
20
L + • _ t. r'v'rL' lir ! i 1. t.
i l,,, •,j ,6 I 1 Y' Aa L t l • " ..• / (/ ' y I A
» I ' -- ; . f!►. }, 'vim .' , • '
• i - 1. .•9t - ?r '• N..,. yr 1+ •
s Y , • ,, ., •' • e+,p Tyr•-• - r "r. : A , .+, r a j ,
WoodWorks® Sizer for ANTHONY POWER PRODUCTS
Roof Beam_ wbc WoodWorks® Sizer 97e Aug. 14, 2001 17:14:38
COMPANY I PROJECT
' DESIGN CHECK - NDS -1997
Beam DESIGN DATA:
material: "Lumber -soft
lateral support: Top= Full Bottom= @Supports
total length: 3.50[ft],:
Load Combinations: ASCE 7-95
LOADS: (force=lbs, pressure=psf, udl=plf, location=ft)
»Self -weight automatically included<<
Load I Type I Distribution.[ Magnitude I Location I Pattern
I I I Start.- End -I Start' End I Load
-----I--------1--------------I-----------------1----'-------------I-------
1 Dead Full Area 15 (4.00)* No
2 Dead Full Area 30'-(17.00)* No
3- Live Full Area 16 (17.00)* No
4 Dead Full Area 15 (3.00)* No
5 Live Full Area 20 (3.00)* No
*Tributary Width (ft)
MAXIMUM REACTIONS and BEARING LENGTHS (force=lbs, length=in)
1 3.50 ft
-------------------
Dead 1 1085 1085
Live 1 581 581
Total 1 1666 1666
B_Length 1 1.0 1.0
###########################################################################
DESIGN SECTION: D.Fir-L, N0.2, 4x6 @ 4.572 plf
This section PASSES.the design code check.
###########################################################################
SECTION vs. DESIGN CODE (stress=psi, deflection=in)
Criterion I Analysis Value I Design Value I Analysis/Design I
--------------I----------------1----------------1------------------I
Shear. fv @d = 96 Fv' 119 ' fv/Fv' = 0.81
Bendig(+) fb = 991 Fb' ='1462' fb/Fb' = 0.68
Live Defl'n 0.01 = <L/999 0.12 = L/360 0.12
Total Defl'n 0.04 = <L/999 0.23 = L/180 ` 0.18
FACTORS: F CD CM Ct CL CF CV Cfu Cr LC#
Fb'+= 900 1.25 1.00 1.00 1.000 1.30 1.000 1.00 1.00 , r, 2
Fv' = 95 1.25` 1.00 1.00 (CH = 1.000) 2
Fcp'= 625 1.00 1.00 _
E' = 1.6 million -1.00 1.00 2
Custom duration factor for Live load = 1.25
ADDITIONAL DATA
Bending(+): LC# 2 = D+L, M = 1457 lbs -ft
Shear LC# 2 = D+L, V = 1665, V@d = 1229 lbs ;
Deflection: LC# 2 = D+L- EI= 77.64e06 lb -int
Total Deflection = 1.00(Defln dead) + Defln Live.
(D=dead L=live S=snow W=wind I=impact C=construction)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verifv that tha r9afa„lr riafl-i-i-,, i;_;*- --- -------
q .
WOOdWOrks® Sizer for ANTHONY POWER PRODUCTS
Roof Beam .wbc WoodWorks® Sizer 97e Aug. 14, 2001 17:18:04
COMPANY I PROJECT
DESIGN CHECK - NDS -1997
Beam DESIGN DATA:
material: Lumber n -ply
lateral support: Top= Full Bottom= @Supports
total length: 8.00 (ft)
repetitive factor: applied where permitted(refer0to online help)
Load Combinations: ASCE 7-95 '
LOADS (force=lbs, pressure=psf, udl=plf, location ft)
»Self -weight automatically included<<
Load I Type I Distribution I Magnitude I Location I Pattern
I I I Start End I Start End I Load
I--------I--------------I-----------------I-----------------I--------
1 Dead Full Area 15 (2.00)* No
2 Live Full Area 20 (2.00)* No
3 Dead Point 1085 3.50 No
4 Live Point 581, 3.50 F No
*Tributary Width (ft)
MAXIMUM REACTIONS and BEARING LENGTHS. (force=lbs, length=in)
1 8.00 ft
---------- --------------
Dead 1 834 698
Lived 487 414•
Total 1 1321 1112
B.Length 1 1.0 1.0
###########################################################################
DESIGN SECTION: D.Fir-L, No.2, 2x8 3 -flys @ 7.749 plf
This section PASSES the design code check..
###########################################################################
SECTION vs. DESIGN CODE (stress=psi, de Election=in)
Criterion I Analysis Value I Design Value I Analysis/Design I
--------------1----------------I----------------I------------------I
Shear fv @d = 55 Fv' = 119 fv/Fv' = 0.47
Bending(+) fb = 1185 Fb' = 1552 fb/Fb' = 0.76
Live Defl'n 0.06 = <L/999 0.27 L/360 0.23
Total Defl'n 0.16 = 1/590 0.53 = L/180 0.30
FACTORS: F CD CM Ct CL CF CV Cfu Cr LC#
Fb'+= 900 1.25 1.00 1.00 1.000 1.20 1.000 1.00 1.15 2
Fv' = 95 1.25 1.00 1.00 (CH = 1.000) 2
Fcp'= 625 1.00 1.00 _
E' = 1.6 million 1.00 1.00 2
Custom duration factor for Live load- 1.25
ADDITIONAL DATA
------------
Bending(+): LC# 2 = D+L, M'= 3891 lbs -ft
Shear : LC# 2 = D+L, V = 1248, V@d = 1201 lbs
Deflection: LC# 2 = D+L EI= 76.21e06 lb-in2
Total Deflection = 1.00(Defln dead) + De In Live.
(D=dead L=live S=snow W=wind I=impact C=construction)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate
for your application.
2. Sawn lumber bending members shall be laterally supported according to
the provisions of NDS Clause 4.4.1.
3. BUILT-UP BEAMS: it is assumed that each ply -is a single continuous
member (that is, no butt joints are present) fastened together
securely at intervals not exceeding 4 times the depth and that
each ply is equally top -loaded. Where beams are side -loaded,
special fastening details may be required.
t ..
PAGE
FROM ,: SUMMIT STRUCTURAL ENGINEERS PHONE NO. 909 596 5187 Oct. 03 2001 02:29PM P2
Summit Structural Engineering .
2283 Fifth Street
La Verne, CA 91750
October 3, 2001 Fax (909) 596-5887
Sun Vista Development, Inc
P.O. BOX 1144
La Quinta, CA 92253
Attn: Rob Capetz '
Subject: Addition at Master
Lot 86, Tradition, '
La Quinta, CA '
Dear Mr. Capetz,
Per your request we are providing additional engineering for an addition at the master
bedroom/bath for Lot 86 at the Tradition. Please refer to the new framing/foundation
sheets S-A and SD -A for framing and foundation information.,
If you have any questions, please give me a call.
Yours truly,
SUMMIT STRUCTURAL ENGINEERING
Benjamin Herbst, P.E.
BH
Attahcments: Beam Calculations '
g:\My Documents\2000jobfiles\Sv-145\145_field3(addition).doc
IN
- Q O •SSJO !
., 193 m
i
9AFOF CA0
Residential, Commercial, Industrial, Land Development
3
FROM,: SUMMIT STRUCTURAL ENGINEERS PHONE NO. : 909 596 5187 Oct. 03 2001 02:30PM P3
_ WoodWorksO Sizer for ANTHONY POWER PRODUCTS
Roof Bearn,, .wbc WoodWorke® Sizer 47e Aug. 14, 2041 17:14:38
_--- COMPANY - 1 P1.2 JECTT
DESIGN CHECX - *IDS -1997
Bean DESIGN DATA:
.araa=a=..=.s__ m-----n.,.==_=..__--------:de_a_==ax__=. .=,.<maa==e=_r==aa m:.m
material: Lumber -soft
lateral support: Tope- Full Bottom- @Suppo:.ts
total length: 3.50 (ft;
Load Combinations: ASCE 7-95
*_..------------- ansa== -am------ ==== - =____ ---- _
LOADS: (force -lbs, pressure-psf, u31-plf,location-ft) =-ass=anYj
»Self -weight automatically included<<
s ----------=-.s= --------- =av=_mm.-ser --==........... a=c_ca
Load I Type I Distribution 1 Magn-tude I Location I Pattern=
I I I Start End I Stars; End I Load
1 Deadead
i-D---i--------------l-----------------I-=----- --
Full. Area 115 (4.00)* No
2 Dead Full Area 30` (17.00)* Nc
3 Live 'wall Area 16 (17.00)* No
4 Dead Full Area 15 (3.00)* No
5 Lave Ful_ Area 20 (3.00)* no
*Tritutary Width (ft)
N,AXIAIUMcREACTIONS and BEARING LENGTHS ;force -lbs, lenclth=in)
1 -3.50 ft
I
---------- -------------------
Dead y 1685 1085
Live 1 581 581-
Total
81Total I 1666 1666
B.Length ; 1.0 1.0
co=ac>------------x=aa-------a- .......... ........... aqa o.x
DESIGN SECTION: D.Fir-L, No.2, 4x6 @ 4.572 plf
This section PASSES the design code check.
>.rs=xaooa-a.----xx-a---.----a--.ani-s----aa=Hama...... .......
SECTION vs. DESIGN CODE (stress=psi, deflection -in)
Cll2 - r,:gcCmx.--a-a»C---------- ------aa-----
Criterion I Analysis Value I Design Value I Analy;:is/Design=i9--..-a
---------------- - - - -- - ------I-------•----
Shear fv @d • 96 FIV, n 119 fv/ ' - 0.81
Bending(+) fb 991 Fb' - 1.462 fb/]`b' R 0.68
Live Defl'n 0.01 = <L/999 0.12 - L/360 0.12
aTotal Defl'n 0.04 - <L/999 0.23 n L/180 0.16
-.-a.a_x
.sa-----=--=.=-------neaaaa.---v.nc-v :..c ----- _==
FACTORS: F .-=a CD CM Ct CL OF Cv Cfu Cr LC#-
.....-aa=xx------------ --------==.==-----x=x =x --w-
Fb'+- 900 1.25 1.00 1.00 1.000 1.30 1.000 1S00 1. OOa=a-m2a
FV' 95 1.25 1.00 1.00 (CH a 1.000) 2
Fcp'- 625 1.00 1.00
E' . 1.6 million 1.00 ;..00 2
Custom duration factor for Live Load = 1.25
.... =aa=m-a---------a=---a----------==a-,Fav------- nn=n...........
ADDITIONAL DATA
c.m-.......aa.---------- -...........eas--m-...---am
Bending( F): LC# 2 - D+L, M - 1457 lbs -ft
Shear LC# 2 - D+L, V - 1665, V@d - 1229 lbs.
Deflection: LCIS 2 - D+L El- 77.64e06 lb -int
Total Deflection - 1.00(Defln dead) + Defln_Live.
(D -dead L=live S -snow W=wind I=impact C -construction).
(All LC's are listed in the Analysis output)
_ - ---------Asa----.-@- --- =-------.=aa=-am--..;.e=a,,,--------.---s
DESIGN NOTES:
1. Please..
-
verify that the default- -
deflection limitsarea .a-.
appropriate
for your application.
2. Sawn lumber bending members shall be laterally supported according to rV•
the provieions of NDS Clause 4.4.1. ~
PAGE zA
Si3MM : is uc'' : ' .. •I•i GI V .i;e: i.:l:'i?n:F . l i iY i1 .9 i ?i5 _ 'A _0 01aR0 ` ;_11111110,i'eF
A.
FROM :: SUMMIT STRUCTURAL ENGINEERS PHONE NO. : 909 596 5187 Oct. 03 2001 02:33PM P4
Y
- � WoodWorks(D Sizer for ANTHONY POWER PRODUCTS
Roof Beam` wbc NV0odW0rkW1P Sizer 97e Aug. 14, 2001 17:18:04
COMPANY ! P9CJECT
T DE IGN CHECX - NDS -1997
Bear L-ES1GN DATA:
------ --
------------- -ply
-- --..--•-^------ -
----------••-----
mater _ -a-
lateral support; Top- Full Bottom- @Supp.orts
total length: 8.00 (ft)
repetitive factor: applied where permitted(refer to onl:.ne help)
Load Combinations: ASCE 7-95
.- ...........mom -------.---a _ va-a>..---..-.-
LOADS: (forco-lbs, pressure-pef, udl-plf, location -ft) .=a -m..--
>%Self -weight automatically included<<
L. --_--...-_e---- .----_-....`.-.---.a--_e---.-... -----------
oad I Type I Distribution I Magni`ude I Loczcion ; Pattern
1 I Start End I Start End I Load
I----------
1 Dead Full Area 15 (2.00)+ No
2 Live ee^ull Area 20 (2.00)• No
3 Dead Point ioPs 3.50 No
4 Live Point 56, i.50 No
`Tr2b4tary Width (ft)
......................------------ ....... ---as.--. ----------- :a----------
MAXIMUM R5ACTIOt'S and BEARING LENGTHS (force -lbs, length -in)
---------- --------------- ..,...-..e-----..----.-.flee- • --..:saw........
I 8.00 ft
----- ----•---------
Dead ! 834 698
Live 1 487 414
Total 1 1321 1112
B.Length 1 1.0 1.0
DESIGN SECTION: D.Fir-L, No.2, 2x8 3 -Flys @ 7.749 plf
Tris section PASSES the design code check.
#q##H#######################qq##q##########A###r♦#N#ff###A#il;♦###990##H###q###
..�.........--------------------------------------- ---
SBCTIGN va. OESIGN CODE (stream -psi, deflec=ior.-in)
asL..terionou Ip ------------------------
- e -- O
AnalysisValueDeaignValueI Analysis/Design .ja.-----
-------- 1--------------^-I----------------I------
_
Shear tr @d = 55 Fv' . 119 fv/Fv' 0.47-(
Bending(.; fb - 1185 Cb' . 1552 fb/Fb' - 0,76
Live Defl'r. 0.06 - <L/999 0.27 - 1/360 0.23
-Total Defl-u0.16L/590 0.53 - L/180 0.30
.....--s-m--------------- -----....:...... =..
FACTORS: F CD CM Ct CL' CF CV Cfu . Cr LC#
..... ............................................... ==------------------
Sb'+- 900 1.25 1:00 1.00 1.000 1.20 1.000 1.00 1.15 2
Fv' - 95 1.25 1.00 1.00 (CH - 1.000) 2
Fcr,'- 625 1.00 1.00
E. . 1.6 million 1.00 1.00 2
Custom duration factor for Live load n 1.25
11 ------------DATA---------------------------------= ------.---- _
0NAL
------------------------- - ---------------- --------- .--------•----•--
Bending(+;; ;C# 2 - D+L, M - 3891 lbs -ft
Shear : LC# 2 - D+L, V - 1248, V@d - 1201 lbs
Deflections LC# 2 - D+L SI- 76.21e06 ib -int
Total Deflection - i.00(Cefln dead) * Defln_Live.
(Dead L -live S -snow W -wind 1 -impact C -construction)
(All LC's are listed in the Analysis output)
--------------------
-- •---------------.,...... -"
-----------__-_---..-a--------.--
DESIGN
............. .,......................... ...................------•-------------
1. Please verify that the default defection limits are appropriate
for your arplication. ,
2. Sawn lumber bending members shall be laterally supported according to
the provi3iors of NDS Clause 4.4.1.
3. BUILT-UP SEAMSr it is assumed that each ply. it. a single continuous
member (that is, no butt points are present) fastened together
securely at intervals not exceeding 4 times the depth and that
each ply is equally top -loaded. Where beams are side -loaded,
special fastening details may be required.
a
wwo
PAGE /3
SItkMt'�'`s7'UI�"• : I31wl�iz PnO ; ? 5 6r? ,'.. 596=3y,� d.m,.::M ,�.�: j ?". 3.v#t1k1R1J; Cry
^r:
FROh SUMMIT STRUCTURAL ENGINEERS PHONE NO. 909 596 513,7 Aug. 01 2001 1 : 1P.14' P1
SUhilmit S,tcuctural-Engineering
2283 Fifth Sir(W
La Vern`, CA 91750
(yQ9 596.08342
August 1', 2001
Fax ¢9q9). 596.518
Sun Vist_ a Development, Inc. '
BOX 1144
La Quintal, CA 92253
Attn: Rob Capetz
Subject: Structural Observation
Lot 86; Tr dtio 7 y-` S _ ,•-y, L , _ 1: '/irC /
., La -Quanta, CAZJ
ti
lDeac,.Mr;.Capetz; ..
In accordance with your superintendent John's request, wed perfgrmed a $
structural observation'for the subject house on'J'uly 27,"2001. The house was
walked for compliance with th6 structural plans and calculations•. A
The: framing looked good, with only a few omissions and dev ations from► :the
plans.,-;. These omissions/deviations were noted (redlined.) ono reduced, roof
framing Ian and' -a copy was give to the framer. ;
IP!
The items were installed the.followiog:day,: and We returned to ,perform the final
check :on J' Iy :31, , 2001.,"At that time: we found .the structure to be m general
compliance W h the structural dasign concept:'
If you have any questions; please give me a call.
Yo_?
urs`truty, `
i
SUMMIT STRUCTURAL ENGINEERING
Nq, 00641 93., ... .
- - - 1y31f03r
Y C
Benjamin, Herbst, P.E.
SH g:1My.Documi6ts 2000jobflles\Sv-145 145_fle1d1(0,0):00c
}
• RQ`S IGYOnS5H1, COmmBrGa t, 7.nau3trial, :Land COdolop.Rltlnt `
• l y3
• d.
07/18/2001- 03:29 7607722302 SUN VISTA; DEV,CORP PAGE 01
FROM SUMMIT STRUCTURAL ENGINEERS FHONE N0, 909 595 519r' - Ju 1. 13 200: M:51PM Pi
Summ' it Structural. Engineering
2283 Fifth Street
La Verne. CA 91750
July 115,.2001 Fox (909) 590-8987
Sun Vista Development, Inc. C,,
P Q: BOX 1144
La Quints, CA 92253
r f
Attn. Rob Capeta
Subje - Structural Observation
Tradiliron Course
L"9 QWits, a
Dear Rob,
Per your superintendent John's request, we"visited the subject job site on July
17, 2001 to perform a structural observation. While we wera at the'job site, we
found seVersl omissions and deviations f orn the plans.. All missing leets were
installed.while we were at the job site and at that time we found the strudure tD
be In general compliance with the structural design concept,
If you have any questrona, please give me a call. !'
Yours truly, -
SUMMIT STRUCTURAL ENGINEERING
•
t+lo Co64193'
Benjamin Herbst P.E.
8H
9.WyDocum&t%2Wl**Mad1®v-1481148_60d1(ceM.doo
4