Loading...
BRES2015-001477153 Calle Mazatlan BRES2015-0014 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: G.L SCRIVENS 74-850 JOIN DR. SUITE A PALM DESERT, CA 92260 BRES2015-0014 77153 CALLE MAZATLAN 658230008 REM /ADD $100,000.00 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT r-: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: ' License No.: Date: ` !" Contractor: ,gr G r I ✓ -Lf C Owl OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any'violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to, an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively.contracting with licensed contractors to construct the project. (Sec. 7044, Business and. Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's n Owner: BOBBY MURCER 5808 CHESTNUT CT EDMOND, OK 92253 VOICE (760) 777-7125, FAX (760) 777-7011 INSPECTIONS (760)777-7153 Contractor: G.L SCRIVENS 74-850 JOIN DR. SUITE A PALM DESERT, CA 92260 Llc. No.: Date: 1/30/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the or for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:.. Carrier:_ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 a Labor Code, I shall forthwith comply with those provisions. Datre:,V 'r3C>SApplicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE INTEREST, AND ATTORNEY'S FEES. . APPLICANT'ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation.. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances.and state laws relating to building construction, and hereby authorize representatives of this city ent r the above- mentioned property for inspection purposes. Dat 3 O Of J5ignature (Applicant or -Agent cc at N O CYZ ga LL Q< Q U C z O U WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the or for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:.. Carrier:_ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 a Labor Code, I shall forthwith comply with those provisions. Datre:,V 'r3C>SApplicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE INTEREST, AND ATTORNEY'S FEES. . APPLICANT'ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation.. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances.and state laws relating to building construction, and hereby authorize representatives of this city ent r the above- mentioned property for inspection purposes. Dat 3 O Of J5ignature (Applicant or -Agent e a C;.. `r k h .«.` , ,.. *9"' S`rr^. r, w+.<_--^ • ; a++ ,+ ' a++a'ia3":,'. k , „ s,;.-. Description: REM / ADD 35 SQ FEET TO MASTER SUITE 1 • f Type: BUILDING, RESIDENTIAL ' = Subtype: REMODEL Status: APPROVED Applied: 1/16/2015 JJO Approved: 1/28/2015 JJO Parcel No: 658230008 Site Address: 77153 CALLE MAZATLAN LA QUINTA,CA 92253 Subdivision: - Block: Lot:T - - Issued: 7 Lot Sq Ft: 0 _ Building Sq Ft: 0 s Zoning:- Finaled: Valuation: $100,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 - Details: REVISION WHILE UNDER CONSTRUCTION SUBMITTED 9/5/14.. - ADD 35 SQ FOOT TO MASTER SUITE. SK NOTE ' i Printed: Friday, January 30, 2015 11:24:56 A 1 of 4 . M SYSTEMS 1 • CHRONOLOGY, ,- , , CHRONOLOGY TYPE'a " ` NAME:,,.. ACTION,D'ATE COMPLETION DATE ", °` ' NOTES .`STAFF ::-"'.-. . .... z .,yrt^ ^.• "ta.. °h,. 'ay. .df. SINCE THIS IS A REVISION WHILE UNDER CONSTRUCTION, WE _ - - GAVE IT A CRW PERMIT NUMBER (SUBPERMIT LINKED TO NOTE ,' KAY HENSEL, 1/16/2015 _ 1/16/2015 ORIGINAL). JIM WILL•GO INTO 14-269 AND DELETE ACTIONS, & REVIEWS AND MAKE SURE ALL IS ADDED TO THIS PERMIT . r NUMBER. ^. GAVE SCHOOL FEE LETTER AND RECEIVED NEW ASSESSOR NOTE KAY HENSEL 1/30/2015 1/30/2015 - PLAN. PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 1/28/2015 1/28/2015 STRUC APPROVED 1/27/2015 .RECEIVED CALLED GREG SCRIVENS THAT PLANS ARE READY TO ISSUE. TELEPHONE CALL 'JIM JOHNSON 1/29/2015 1/29/2015 ALSO NEW ASSESSORS SET REQUIRED. CONDITIONS, i Printed: Friday, January 30, 2015 11:24:56 A 1 of 4 . M SYSTEMS u w Q•C4. 0 a, cr"f`oFx�° INFORMATION , .ti ` 3e ;�k .� ...fsp '"ra4,.. .s. f.''.� +:t....i ::�.G....:. ,.,`x.�.f�..Vi,`s:A.< �. SSid s�Eq fh '_.rT.::—_te ;r7:,:Z�' �.�,�:. �4�,y•. ',ca4� _ '�x�Bk�S'.c�• a: «r�i = �..3._�_:; .._..,�.'i.--4.:.F.. t <£. NDI0TIAMOUNT '. O 4•+�Wa'.".'pF. PAID :.r-.DAT*Er '.,.'.. ''�"'',:�:' NAME TYPES .�ae,ws ,.: . . t .,•.: i�•.s ":, t:'#':: ,., +- k °'-.... F,:"caC nrx.. `.:* i — ,x+`� NAME: " ". J ;:°CITY: ";STATE, ZIP ' ;,.PHONES a .. RESSi ,�>iRp�I. d `.'i�'�T.s FAX'" REMAIL: ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ST10ADDITION, FIR0 SF 101-0000-42600 0 $171.14 $0.00 , APPLICANT G L SCRIVENS CONSTRUCTION INC P 0 BOX 13302 PALM DESERT CA 92255 CONTRACTOR 13SAS.SB1473 FEE G.L SCRIVENS / 74=850101N DR. SUITE PALM DESERT CA 92260 - A { Total Paid forBUILDING STANDARDS ADMINISTRATION $4.00 $0.00 BSA: RESIDENTIAL, FIRST OWNER 0.. BOBBY MURCER 5808 CHESTNUT CT EDMOND OK 92253 INFORMATION , .ti ` 3e ;�k .� ...fsp '"ra4,.. .s. f.''.� +:t....i ::�.G....:. ,.,`x.�.f�..Vi,`s:A.< �. SSid s�Eq fh '_.rT.::—_te ;r7:,:Z�' �.�,�:. �4�,y•. ',ca4� _ '�x�Bk�S'.c�• a: «r�i = �..3._�_:; .._..,�.'i.--4.:.F.. t <£. NDI0TIAMOUNT '. O 4•+�Wa'.".'pF. PAID :.r-.DAT*Er 7H. E<.,,• CPAID . t,px •9. '-•'. *�r....,: ..,+;,..'-.te.t�' :s..,4j:.,:..t •�''a.{. ,�,mE�t`;.'€`>-,.. . z. b,rK_ ±:�. ��ibo ..�z�'t°�'R ' `$ �;:s:E'{.,.:. , .s` E;�a. t <,i ��f�.. - . , : h . si ,�>iRp�I. q°� , <.:c!�•".:.r; wx . :. ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ST10ADDITION, FIR0 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $291.97. $0.00. 13SAS.SB1473 FEE 101-0000-20306 0 $4.00 $0.00 - { Total Paid forBUILDING STANDARDS ADMINISTRATION $4.00 $0.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0.. $145.03 ' $0.00 1,0005E RESIDENTIAL, FIRST. 101-0000-42600 0 $47.86 $0.00 •1,000SF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $0.00 APPLIANCE 101-0000-42402 0 $12.09 $0.00 - REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83. $0.00 REPAIR/ALTERATION PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00. EXHAUST HOOD PC .101-0000-42600 0 $4.83 $0.00 Total Paid forMECHANICAL: $33.84 $0.00 FIXTURE/TRAP 101-0000-42401 0 -$12.69 $0.00 Printed: Friday, January 30, 2015 11:24:56 AM 2 of 4 ' SYSTEMS Printed: Friday, January 30,2O1511:24:55AM 3of4 _—_----_ ---- AMOUNT .'PAID 'PAID DATE, CHECK.#: 77 FIXTURE/TRAP PC 101-0000-42600 0 $12.09 $0.00 OUTLETS GAS SYSTEM, 1-4 101-0000-42600 0 $24.17 $0.00 OUTLETS PC Total Paid forPLUMBING FEES: $60.44 $0.00 REMODEL, EA 101-0000-42400 0. $43.50 $0.00 ADDITIONAL 500 SF REMODEL, EA 101-0000-42600 0 $34.80 $0.00 ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 REMODEL, FIRST 500 SF Total Paid forREMODEL: $262.49 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI $13.00 $0.00 Printed: Friday, January 30,2O1511:24:55AM 3of4 _—_----_ ---- KATHRYN STRUC TO YOUNG - DUE 1/29/2015 STRUCTURAL SAMUELS 1/15/2015 1/29/2015 1/28/2015 APPROVED APPROVED STRUC APPROVED All 114 Printed: Friday, January 30, 2015 11:24:56 AM 4 of 4 SYSTEMS ay`j : ° IPTION .' ; %^` s" j "Fi '3 <vC FEW" 4"'f.,',' rR-41 Q :^4Y.''` . ixs vyY:v^ _ N' ., [ AIVIOl1Nf ' T ,Ys ...Trw 4 E ":x s 24- ', PAID DATE ^; : ,:u':'A8_emiffL'"wv...'ia.°.Y.SLSsk'v_nL...,.'-a.2.x":>°`"x,,.E.....zz<"s'`4'P+,{ie..v' r,;,::`G ?'..i"".'..xY.x" '. :.;?9.Y.v«zwk:. y Wi: .PAID '`uX`.'c ' „ + FIXTURE/TRAP: 101 0000=424011. 0 `$12 09. $0.00 .: h. r4 s <;-,::.-.f f PAID`BY 4s,; THOD' RECEIPT # R € w CHECK # _ s +' CLTD BYE ,M*.: rr-:.. „x r.- ., a>uF ::.M x «.: s: a.. i.,:,:f -> W:..::£ 'N' %,. '°-,.ar'. K4-. 4• Z:YF ,ars sib: .. ... DEC9Z:: _eY :tersi.3s RIPm.;.S3 v ?OiAt: 60UNT= 3- .<% :.a,fr9"',:+,..£. i.;[rza^r dm{ gPY yP $A'Di+,DA°T'vEAMOUNT I:QT71m r.. a:r!.ItY,4.... rs'Y ax rS::.a<.-a,,<=...s?'.zY eP a?*;$a ry'.,<..,.e ,xr . y4F-fs ::RwY.:s;.....?.W< :':'xSM .CY.4: 3}c #'R^ Y,.• FIXTURE/TRAP PC' :101'0000=42600 $0c00 ~ , ,e g ` .. ,'' '+:Y's 'fig.3 ' " ' ..t e.,xyrc" igrrka"is,. 3 .'a'°., e A PAID BY s ' ' -a .`pis— ^ '> z:-. , . ;Y' .a .-'-.:.:.x' .e z- :RECEIPT;#,r .,x:«.a« ..a _'s` t Y:.'. , . ;, *,l -a x '^ ;",`x .t;.;G; # <::Z( V 7",. ..CHECK CCTD BY ,✓.s", ':DESCRIPTION rigs- .`"'`K£ h ACCOUNT`_ Q TYgMOUNT: PAID 3` d2,3a?,'. .i'+ « PAID DATE if < v§n.v£ ay.....?&,>°'.=:W.. `3-.:'er:,k:4.:. ffY.icia>r x 9 >z..".:''-•iead" x °,: ' x .*#. ' ._-;' .s ... &':k4 ' fxk FF! ..' n w:'hE.Yk4$,RPPOfi: Y.f :'wn ,r i89ewd,.. - GAS SYSTEM, 1 4 OUTLETS :i ' _ :> 101-0000-42401 * 0 ; ' $12 09, $0:00 R :y C..'x4:Y a; :vMETHOD A E, urss`k}:.x.,.t?H5 %..=fs au Si@¢'•' x°° AECEIRT ..j'-.k"'.':nE`:.f 'ai'.4! ' s `,,. «'' CHECK ,3.:..._.Pr`-• BY :T ta£.tY 4':ez<va`S?.x,.-s. .. <S.*;Sa.'S.+'ziC>rfFce `.`'' -3£P3 fig. {.F1A Ew,b'iy:..'«fi fi". .k. +v'a 5 W;,x cp•£.'.:3 t#2xi 'rrs .x,YT F"Y Y",3.>'w'.-> .?S i^'.r' PAID ,5 YDESCRTON. ;`. 4000UNT'_. QN4 AMOUNT" _ AIDDATE4 'GAS'SYSTEM, 1 -4 OUTLETS PC';:' 101 0000;42600;- „ 0 $24 17 $0:00 _} a` a.fr ,. ; e' „}fr ,PAID=BY rMETHOD ;; Ec .. _ 2;",r;`>'., 9,`e:a>_a;.__ CE : + Zfn`mq. ir' a r HECK :r aMxvv!', r...Y:`.... 3 # CLTD BY s ». i't.dku..f{. m_sxa'af'4'Gxni:.l-+mv,vx.... `dXSTv: ...i .Fr-,v.'c" `Ya n .11Z, iH0 CM2 . wn, 1- s i_ 'Total Paid forPLUMBING.FEES $60 44 $0.00 b .,. .£ ?' a '" nes':-a.r-#..4f s#:..n,. ff DESCRIP<TION '' e''°Ss'r's.6s,.: ACCOUNT ' TY gMO UNT „ PAID ", 7wSy'x,.5,s;.; 4 PAIDDATEF r0i«i::? Q>a °REMODEL; EA ADDITIONAL 500 SF, 101 0000-42400:: 0, . = :. $43.50 , $0:00 ire ,Pa": ': f{ 4L'S iE:, ,L.. sr. f. 4`f, 4., '`✓Y Flif ''re'{tt'<'Yix'>':' 3>°P§< METNOD< . _ Y..K "'S 'rl:"'sYr,kiFYESi'K E4 RECEIPTy# aw£CHECK :., sz. hR # rCLTDBY '` x;.i`.. j.4 , s waas :V> .3dLup., 'ekkln.`if £. , tUESCRIPTI .i . g` ✓^.. A000UNT«fs, QTkY„, ` a" z - gIVIOUNT. .:: A- x 4 x. PAID PAIODATE :a -REMODEL :EA ADDITIONAL 500 SF PC 6i-0000-14260 ` 0 $34.80 $0:00 y' :' 6 , : A-Mp*6: n ..dt s s,}- rsY .Y Y 4 2 { 4j$ BYx .. 6 z k 3. "i', W.,?S:. 3 ?u.y, 3s.:"e's a ..a M .¢ METHOD. ' ...,. x : > -. c.i . d::.:: ;- .L e 4 sinPAID #,..- t §..° ani _;.iv:.«,.: E CLTD BY ..x .._. f .,# s,.'k:L,..r.a:>x ,a:._ :4ai:>a.°ifl ;RECEIPT (CHECK,# T e: ' Frtte'k.¢ a*,+ykd`W ;.-,a' S' n' DESCRIP,.TION gi ACCOUNT TY - - ANIOUNT ... € ' • '°. §S't'S , 'e . o . 't'' E.17`:hd": ' ., iS . r . <. , nmri ark f” h .,res M ak ?PAI 061-11., r..RAIDDATE: REMODELJIRST 100 SF ti ` 101-0000-42400 '' J 0 : $49 31 $0.00< . gg =s...: r., :. PAIDBYx- NOW 'E911271-711 METHOD„ I5....a.sas , L RECEIPT# - CHECKS# CLTDBY a r 9 ' DESCRIPTIONhk' .. .4sx x : .. s gCCOUNT g , 101 0000-42600`,, Nn i.Q `, 0 K AIVIOUIVT $1341,88:,,,',7. ' a r PAID '$0:00 a PAID DATE+ .`.'REMO,DEL, FIRST 500`SF PC i. v sm : PAID BYE QN A ID1_7..-..:.x3xw..a"3 s x ;, ag, ` 5 aa' ; ` igE.j df RECEIPT#b t r CHECK# CLTD=BY METHODa, II t-- Total Paid forREMODEI $262 49 $0'00 Ew ;t z...*, DESCRIPTION MIR x :; ;r `A000UNT; QTYAMOUNT <..w a*„x_ EPA PAID u.> < < _. u. ., . ,:,.',. GERM 4 s s z<-. s .< ,. .. ._ a r1n. .: f ate DATE ^ I!N ,,SMI:,, RESIDENTIAL 101-0000-20308'.: 0 $1300 A of EB or.....: a_'Rye' fig, CEfr FT CHECKS#'.CLTD BY= : 1 .E z r Total Paid'forSTRONG MOTION INSTRUMENTATION SMt .'.' $13.00 $0.00 5,15 e e ee I IBM W ' -5 S 4 ;v " r ?< 7• c,. d E , S t j.;., R a ft I x )' r ,.1 Y> "`,:<, br','& `. - ,;,wJr s4 :, ^F" `-r : _j.zk-,,rS L"P „eh roe`.: ._ 4 L C'+ : •' `' DE IP, k' rs -$^« #cam+a, sO.., „. fi"r ! SCR TION ACCOUNT QTLY TE . ,, : AMOfUN i? 'RN. D PAID D 5T13],ai<&,T1{Fffib-':53_a.: `. -<.,i'.:'ac„Z, :.:.z' .a.ie$:3::,ou' .': n:I i Y :S uaei.,o:. d€<: ADDITION, FIRST.100, 101 000042400 .; ; °0 $120 83 '. $0,00' e A Z .},ps,'fit, .'$-,zz a` ,.Xi""f'- 1¢ f "E h =d>' . T4. !F C iE ':F f•.:'rK3€•.Y+'ie:i `'i `ats"' 'wr>3 .5h ,i?C. s'.. , ! Sy -'`-4f ..s PAID BY < :`_.,FG- _Mi:Wu.RECEIPTSn e@LTO BY,xa ma,4.. .. '.-:., rs? ,f r.,,^. sYi'F'>'- s.wr 'i,' N"';;'q:. -.= '".. , i >??:& `` !`d, ,.OESCRIPTION ` ' '.A00OUNT ;x QTYANIOUNT rr.;fr=3' .F_ ix "7 :,'±' .. t a?aT_ ' PAIDPAID. DATEI s x t - .. " ADDITION- FIRST -100 SF PC 101 0000-42600"`` 0 $171 14 ' „`. k $,0:00 c. 3ew:: °vn' " <W v'v+.6:&"J 'I"110 sc', k -.0 ...E sMETM D„ € H..; 3 O y '8: s H;- RECEIPT #f} CHECK # CLTD BYE qr ,yPAIDBY E < tiR!AP.t.<;em n,..<s1r ::..`J.l...aa:,""a a. f>f<#A;<,<til<kr.az Sxk«.".x..,'.^ :, >a'k.'.,P.:F rr 4 r .. Total Paid forADDITION 5 _ $211.97 $0:00 , :.'s`W<c,.:s<.. '$-a,?=i`...y Y' .# ".. "° '5 3 r” ..,E lt.EY.'z°'R+..av,tF"k3`' , J: $•' k?3 ';v."'a.'.. w' °AMOUNT`' -";, p'AI > = P< `PAIO?DATE ;DESCRIPTION" < t. l'C3 ..'i' .'N._ a& -ACCOUNT aQTY. 4g'.'Y.'u.x.fi` E.r ➢.`,'4'P>.......rv:i_d's:'<$kf''i i5, -AID F r'!'.i.-;f: `... {BSAS 581473 FEE,_ , 101-0000-20306i-, 0 ,: a :: $4 00 $0.00 4 •' PAID+BYE z..' a. g-,# c . .a,g<.!` a v4 jEa .R G ,!<N" 'J< 3-`-: t MET,FiODg REGEIPT . , '. .:' 4xx,"Aa`T.l .x,' >i' C:- _ # 3 ". :l<"Z`` a ^a&-2jn {.' 4>' -3:aai .. ke `CIECK,# i x. ,U.n r.; ... s'£`4iE'rt ..,.6a4i.-.;aY,3`>ii ^.`rW c.", ' % _r. ... naa ec.. ;.y3y " '9E Y:",+s:. «-vYv ^ :'r l EL .• ' Total Paid for B_UILDIN i!STANDARDSADMINISTRATION BSk '- '$4 00 , . o `'' '. •< X44'<`T K OESCRIPTION ' - 'r .. a-`,`:.9EAv4a'".<"'j I t 'u kCYr` QTY _g; ; 5 P ID DATE _ACCOUNT I W :F Z' ,AMOUNT c r m: .PAlD+ 'RESIDENTIAL, FIRST lj00 SF ; 101-0000-42403. 0 a :$145 03., . $0:00 . i. t ^ 5.:.. ✓' u.`v" us €S:: k.z `' a :-+„ _ :*l x' A!* x ....Kw 'Wm . ,. .? `.xe'r Tit', . - x' •, , 3ff` R w. - . CE PTx#ir y. r- 8 ",5E 6k 3 _ - CHECK# # :.tup” . tw BY • sr _....w' txq. sz; CLTD . , k ads -3.:. E '?wiz :£' 3,{CY «'e:.*Y,. v-.>t4, C'it SFe :{Y:a'i,vNY. . '`E >3 .'. ,z + 'DESCRIPTION : ,£: '.t<Ai!"thf v*` T,A`> C ' ApCCOIIJNT :.. ->o TY 4 ,E 'E'Y +E .6.,'gyS = ` `AMOUNT.' .,P.A"ID "ri:z.;. ,ae«Y. %.Ir3, `< ,4. 5,✓` i>^`%<C.iar.:. TEc a. :.:E" a; rax.as,m , r iis s,Q: s; aE, : PA DyDAWn RESIDENTIAL,1FIRST 1,000SF, PC' ' 101 0000 42600 0 $47 86 $0.00 " ,T k5`h;"' ',R .➢Wi,,!'zl.E"a' r•`4- . PAID BY d 'ii: METHOD"`RECEIPT t.: '4C =° Ym :T Wt Raw # ? ' ,. ;. .: .zs . x',i 4 k ? _ e r .t: k:.I giH . s rs. a.<: TO- .jT BYH 48 Total Paid°fot.ELECTRICAL - NEW'CONSTRU,CTION 4:.` : `$192.89'$0.00 4'' aY d ,kn'zk.`.k: al,4. ::u't,Seaai^'Sfi n4"ry K "„.=Ys,32 N <s F. . DESCRIPTION :a <i & rep `qK: ^., 4. T L L;y^y,v': r$Fpwd, {., 2 ' ."L :w Y$F vY,n!:Ytt9 L,. ... ;5.` a{ r r'>' . `. i..ssp :Cx ,, , w :t ,. A000IIN f kQN AMOUNT . ° AID HIa ^ r5 PAIDDATET APPLIANCE REPAIR/ALTERATION F 101 0000'-42402 `z: 0 $12 09, $0.00 ga gR`g R'Y 4 < a4 ' ,vkYG'S3, mw,q KF`R WIN- PAID_BY WIN- 5i >4. RxrF;"v` xi-§ ' METI Q 5., ' r z ":, ° ` • . e a5 RECEIPT # R :Y;.: "-' [s , ,i<:.?zGa',.,v . t> ?.. , $ - S,E CHECK # w: q- R.: BYE, . ". , z . 's E " 0 70 ,, CTD E <. - t< ! h r DESCRIPTION 'ACCOUNT roi` ' ' ?r`}. tm"i.'i `g:;.., A i .- .a.i?',rl;R; +'`$ TY Q 4ts s g ; xat x'S ^Pxia t4'. PAID,DATE< r x ::Si,,. E-A`i-,.v.a3<F `.s?4f ... -i x'.:?!Lr.3,i-> E::, d Y i .eAMOUNT, :"aPAID,« d...z _,"u4> - ° AFP_ LIANCEREPAIR/ALTERATION PC °; 101 0000=42600 0 ; $4 83 ,- $0.00 `.ak-: `' '{rl' ' fi s PAIDBY .nz` i'x' q'g!X.; .` :F$i'gi 3«.,"slPa,"P?. AHAI 4q .jgg'r k1 ,F ` ( r :., METHOD" I ` 'y ;:ur,$,r ..-. ., z cWIMM„r'I'wF; :F.'S'` .1.. -3 ' RE nEIP .ta T re Yy1': t ;b 9 Fq CHECK € . ,E .r; . µ #3 ZCLTDBY. d 0< ta " 3^Y 4g'@[i ...¢.,.Er „fxy:.33-` ,z, ,• ,..>F . gE.;:°sT E i s xir DESCRITION...` r a +$rxc4,E>` . `t , : " ACCOUNTS F, t t AMOUNTS ,a3 ,q ; PAIDaDATE Z'a-xY:..''+En..,.r , .S.i SiA..x..•".v -- ...-s _ . r$,..i.sa 1nZ ,....la „w.wr. *,..,.,n7':€I.a..,<: ,P',`.Mn.^ W. 'QTY w:i tl ..+ m .w..e:,:d; v a-_. ,>... Y✓.,',"F,.,U xaPAID s r.. c._ = .r .... n'e3 EXHAUST HOOD, 101.0000=42402; 0, $'12.09 $0.00 e : , " :. .:. :. , ,. ' .. •,f 1, OESCRIPTION . . ir2q 'T,,—.as.,'n?;>„enc...v ,;;.r... s .,=^:?rn- : ? t iYa ;u: ±' " w <..: @ x E F ACCOUNT i¢"! ,iYa°:. sa'K*.. d- „3 -+'`-E E zag TY AMOUNT ^s':s t<..' sa g" `a`& PAIO .g'; .x ''. R%8 ,,€ PAID DATEr, R,—, .7" .:x S F I .::k ..E 3 ".E^x=,^. H t.f ; ?" , , NU . EXHAUST, HOOD'PC 101 0000,=42600 ' 0 t $4 83 2' E„'r Sw'f.'p rti`4$>;+?kX:''i{.-ate`.(.,. .. k iF: QF q*: t"o:'• MT METHODS , ,:ham 3R E 3€ n RECEIRT # ¢vZ%R=- ad ',', ` xCHECK# ; < CITDBY 3 SSF::aR':&L"sz'st`r::z+;:F0iz. <=_ ._ YTotal,PaidforlVIECHANICAL33184-$0.00 S 4 ;v " r ?< 7• c,. d E , S t j.;., R a ft I x )' r ,.1 Bin # Permit # • QO ► City of La Quinia ' . - Building 81: Safety Division P.O. Box 1504, 78-495 Calle Tampico . La Quinti,CA 92253 - (760) 777-7012 Building Permit_ Application and Tracking Sheet Project Address: t I lVjZ✓* Owner's Name: r A. P. Number: Address: Legal Description: City, ST, Zip: C Contractor: G// J C o -*,(Y Telephone: •%b a Address: -7 eJ 5;_!:'C>' • s -T4 , . Project.Descr-iption: L i City, ST, Zip: jeIrl, >e_T-t Telephone: -76 a q5 t.1 3. :..<r.•.::::><:><°<'"i `'>s ..... State Lic. # : 6 e-/ j City Lie.A. -- Arch., Engr., Designer: Address: City, ST, Zip: KG v .J l6 (Jove C } Telephone:ne: `...:<:s;>:<.':,.':s ,•,>>s `'s. "":. ..'..:,s,`:> <><,`:<::::<:":<=:-?•>:< oOccupancy:Cnstruction Type: :iify ^Y{!Y,'::•;f '22*'.l .^:?ti(.<:L:i State Lic. # `r«%'="""'>">F»`<:<.>_ :r«'i' :.<..:: r;:.i.::::...::.r.:::;;::.;;:::::: Project type (circle one). New Add'n Alter Repair Demo Name of Contact Person: S . Ft.: ries: # Units: Telephone # of Contact Person:/ e ! Estimated Value of Project: j APPLICANT: DO NOT WHITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES. Plan Sets Plan Check submitted (; `[ ( % Item Amount Structural Calcs. Reviewed, ready f corrections Plan Check Deposit Truss Cala. Called Contact Person 5117 Plan Check Balance. Title 24 Cala. Plans picked up G U Construction Flood plain plan Plans resubmitted 1 IS Mechanical Grading plan god Review, reny for correctio srssue 12-1 Electrical Subcontactor List Called ContactPe 2 Plumbing Grant Decd Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'rd Review, ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees , Total Permit Fees cl Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Greg Scrivins Check No. Bank Name/Recipient of Certificate Telephone 760-831-7439 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exempVd by CERTIFICATE OF COMPLIANCE Desert Sands Unified School District q! r n 110rey Payment Recd _ E . ver/Under= :moo 47950 Dune Palms Road ¢ SERMUDWDUNES° Date 1/30/15 / q La Quinta, CA 92253 Cn RANCHO MIRAGE INDIAN WELLS No. 31697 (760) 771-8515 P14-PALMDESERT LAN DI Owner Bergenser APN # 658-230-008 Address 77153 Calle Mazatlan Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 77153 Calle Mazatlan 80 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 80 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Greg Scrivins Check No. Bank Name/Recipient of Certificate Telephone 760-831-7439 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exempVd by M . Signature r. NOTICE: Pursuant to Government Code S ction 66020(d)(1), thi I serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant 'Copy - Applicant/Receipt Copy - Accounting n 110rey Payment Recd _ E . ver/Under= , M . Signature r. NOTICE: Pursuant to Government Code S ction 66020(d)(1), thi I serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant 'Copy - Applicant/Receipt Copy - Accounting B.G. STRUCTURAL ENGINEERING BRIAN GOTTLIEB - CIVIL.ENGINEER - Lic. No. C33047 . 75-175 Merle Drive, Suite 200 . Palm Desert, CA 92211 `; (760) 568-3553 (760) 568-5681 Fax : Bergenser Residence Remodel Stracts Inca - 550 S. Oleander - Palm Springs, CA.92264 ' Job Number: 908.08 January 9, 2015 ' Field Revisions - NECEIVE• ITY OF LA QUINTA` F DEPT.. BUILDING & SA JAN 15 2015 OR ' CIN 0F LA QU INTA' COMMUNITY DEVELOPMENT DATE - .630-16 s CNII- P q OF CALIF ' VALID ONLY IF SIGNED' IN RED - PROJECT SHEET NO. Bergenser Residence R'iodel B.G. STRUCTURAL JOB NO. 90808 ITEM Beams ENGINEERING. DATE Jan. 2015 ENGINEER BG B.G. Structural Engineering, Inc. 75-175 Merle Drive, Suite 200 Ralm Desert, dA. 92211 1-760-568-3553 Voice 1-760-586-5681 Fax Project Title: Bergenser Residence Remodel Engineer: BG Proiect ID: 908.08 Project Descr: Printed: 5 JAN 2015. 2:49PM 1• 1 wood - sK!V-'06.d.03989#F;n'at?iesrr«ar i.'L''i eriseeBGSTRUCTURALENGI[JEERING Description : Beam B3 (Added 1115) CODE REFERENCES . Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set: 20121BC&ASCE7-10 Material Properties - Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Analysis Method: Allowable Stress Design Fb - Tension 1,300.0 psi E: Modulus of Elasticity Load Combination 20121 BC&ASCE7-10 Fb - Compr 1,300.0 psi Ebend- xx 1,600.0 ksi 1 Fc - Prll 925.0 psi Eminbend - xx 580.0 ksi Wood Species : Douglas Fir - Larch (North) Fc - Perp 625.0 psi 6x10 Wood Grade : No.1 Fv 170.0 si 1,247.10psi fv : Actual = Ft 675.0 psi Density 31.570 pcf Beam Bracing : Completely Unbraced 212.50 psi Load Combination +D+Lr MUM 1-0 0.28) 0x1u Span = 11.250 ft Applied Loads - Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads 36.64 195.50 0.00 Uniform Load: D = 0.2520, Lr = 0.280 , Tributary Width =1.0 ft, (Roof) 0.00 2.29 DESIGN SUMMARY Length =11.250 ft 1 • o Maximum Bending Stress Ratio = 0.772 1 Maximum Shear Stress Ratio = 0.356 : 1 Section used for this span 6x10 Section used for this span 6x10 fb : Actual 1,247.10psi fv : Actual = 75.59 psi FB: Allowable = 1,616.18psi Fv : Allowable = 212.50 psi Load Combination +D+Lr Load Combination +D+Lr Location of maximum on span = 5.625ft Location of maximum on span = 10.470ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection 1.00 +D+Lr Max Downward Transient Deflection 0.161 in Ratio = 836 1.000 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 1.00 Max Downward Total Deflection 0.313 in Ratio= 430 0.772 Max Upward Total Deflection 0.000 in Ratio= 0 <180 1.00 Maximum Forces & Stresses for Load Combinations , n n j IINTA Load Combination Max Stress Ratios Mo. Segment Length Span # M V Cd C FN Ci Cr Cm C t C L D Only - 0.00 1.28 36.64 195.50 0.00 0.00 0.00 2.29 65.85 Length =11.250 ft 1 0.519 0.239 0.90 1.000 1.00 1.00 1.00 1.00 1.00 +D+L 1.000 1.00 1.00 1.00 1.00 1.00 Length =11.250 ft 1 0.467 0.216 1.00 1.000 1.00 1.00 1.00 1.00 1.00 +D+Lr 1.000 1.00 1.00 1.00 1.00 1.00 Length =11.250 It 1 0.772 0.356 1.25 1.000 1.00 1.00 1.00 1.00 0.99 +D+S 1.000 1.00 1.00 1.00 1.00 0.99 Length =11.250 ft 1 0.406 0.187 1.15 1.000 1.00 1.00 1.00 1.00 1.00 +D+0.750Lr+0.750L 1.000 1.00 1.00 1.00 1.00 1.00 . Length =11.250 ft 1 0.672 0.310 1.25 1.000 1.00 1.00 1.00 1.00 0.99 +D+0.750L+0.750S 1.000 1.00 1.00 1.00 1.00 0.99 4.17 4.17 fb t nFibS . & SP"" r fir- F'v v `Fk COY 0.00 604.57A9215' T12p N153.00 OR SNS Fob 0.00 0.00 604.7 1294.46 1.28 36.64 170.00 0.00 U10 O.O---,Q= 8.60 1 1 247. ° 1616.18 bA.0 4.17 487.59 0.00 7.49 1,086.47 1616.18 0.00 - 0.00 1.28 36.64 195.50 0.00 0.00 0.00 2.29 65.85 212.50 0.00 0.00 0.00 B.G. Structural Engineering, Inc.' Project Title: Bergenser Residence Remodel 75-175 Merle Drive, Suite 200 Engineer: BG Protect ID:. 908.08 ,✓PaTm D sorf, A. 92211 Project Descr: F 1 • 1-7150.568-3553 Voice 1-760-586-5681 Fax . • Printed: 5 JAN 2015.2 ORA WOOC -"13@a111 File =.0EC6•DA-11STE81D-1.EC6 ENERCALC, INC. 1983 2014, Build:6.14.11.18, Ver.15A4.11.18 } Description : Beam B3 (Added 1115) Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i C r C m C t C L M fb • F'b V fv F'v Length =11.250 ft 1 0.406 0.187 1.15 1.000 1.00 1.00 1.00 1.00 1.00 4.17 604.57 1487.59. 1.28 36.64 195.50 +D+0.60W 1.000 • 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =11.250 It 1 0.293 0.135 1.60 1.000 1.00 1.00 1.00 1.00 0.99 4.17 604.57 2065.14 1.28 36.64 272.00 +D+0.70E 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00 Length =11.250 ft 1 0.293 0.135 1.60 1.000 1.00 1.00 1.00 1.00 0.99 • 4.17 604.57 2065.14 1.28 36.64 272.00 +D+0.750Lr+0.75OL40.45OW 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00 Length =11.250 It 1 0.526 0.242, 1.60 1.000 1.00 1.00 1.00 1.00 0.99 7.49 1,086.47 2065.14 2.29 65.85 272.00 +D+0.7501-40.750S40.450W 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00 Length =11.250 ft 1 0.293 0.135 1.60 1.000 1.00 1.00 1.00 1.00 0.99 4.17 604.57 2065.14 1.28 36.64 272.00 +D+0.750Lr+0.750L+0.5250E 1.000 1.00 1.00 1.00, 1.00 0.99. 0.00 0.00 0.00 0.00 Length =11.250 ft 1 0.526 0.242 1.60 1.000 1.00 1.00 1.00 1.00 0.99 ` 7.49 1,086.47 2065.14 2.29 65.85' 272.00 +D+0.750L-#0.75OS+0.5250E 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00 Length =11.250 ft 1 0.293 0.135 1.60 1.000 1.00 1.00 1.00 1.00 0.99 4.17 604.57 2065.14 1.28 36.64 272.00 +0.60D40.60W 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00. Length =11.250 ft 1 0.176 0.081 1.60 1.000 .1.00 1.00 1.00 1.00 0.99 2.50 362.74 2065.14 0.77 21.99 272.00 40.60D+0.70E 1.000 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00 Length =11.250 ft 1 0.176 0.081 1.60, 1.000 1.00 1.00 1.00 1.00 0.99 2.50 362.74 2065.14 0.77 21.99 272.00 Overall Maximum Deflections Load Combination Span Max. "2 Dell Location in Span Load Combination Max. W Dell Location in Span +D+Lr 1 0.3133 5_.666 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 3.057 3.057 • ., . Overall MINimum 0.889 0.889 D Only 1.482 1.482 +D+L 1.482 1.482 +D+Lr - 3.057 3.057 +D+S 1.482 1.482 +D+0.750Lr+0.750L 2.663 2.663 +D40.750L+0.750S 1.482 1.482 +D+0.60W 1.482 1.482 +D+0.70E 1.482 1.482 +D+0.750Lr+0.750L+0.45OW 2.663 2.663 +D40.750L+0.750S+0.450W 1.482 1.482 +D+0.750Lr+0.750L40.5250E 2.663 2.663 • _ ' +D40.7501-40.750S+0.5250E 1.482 1.482 F F 40.60D+0.60W 0.889 0.889 r +0.60D+0.70E 0.889 0.889 D Only 1.482 ' 1.482 Lr Only . ,1.575 1.575 , ` L Only S Only , W Only E Only H Only CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE - sY"' . CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Bergenser Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 11213112014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC -1 Existing Res 1,513 15,584 1980 Addition 36 371 Totals 36 1,513 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC -1 1 Central Furnace 80% AFUE Packaged Air Conditione 12.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status A. 0. Smith 75 Gal. 1 Small Gas Kitchen Pipe Ins 65 ,.._7_5 0.72 n/a n/a Existing I r 4 i -V ,n - I -- ^R. o LA MULTI -FAMILY WATER HEATING DETAILS HYDRONIC NE-ATING NSYSTIMV, PIMNST. Control Hot Water Piping Length ft s - N ¢ I /AH 1 FOR CONSTRUCTION Pipe S stem`Nam _Lev th G Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried ❑ " EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 201412-31T15:17:50 ID: Pae 8 of 17 MANDATORY MEASURES SUMMARY: Residential - Pae 1 of 3),- MF -1R Project Name _ Date Bergenser Residence ` . 11213112014 NOTE: Low-rise residential. buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach ued. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R - Form with plans. x' Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form: §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. f - 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.• *§150( c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. ' 150 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake„which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the . outside of the buildiri, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. ` §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr.are exempt), and pool and .spa heaters. I .!, -. - • §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. = -” §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). ` §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. ' §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water ea i. -n — em or 6tfYeritrdirecYhotwvate tanks have R-12 external insulation or R-1 6 internal insulation where the internal insulttatio'n,R va .I is odi at uou of of he tank. 9~ RI III nim(a §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating syste s, an Uentire I n f recirculatingsections of hot water pipes are insulated per Standards Table 150-B. 6 /F §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated betw`ee'n i erecJht water tank shall be insulated to Table 150-B and Equation 150-A. I §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards able 123-A. ' ' - j DATE'RY 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisturle; a ui ment-mai §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in' I- •. conditioned space. 150(i)4: Solar water -heating s stems'and/or collectors are certified by the Solar Rating and Certification Corporation. ' EnergyPro 5.1'by EnergySoft User Number: 6712 • RunCode: 201412-31715:17:50. ID: _ Page 9 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date 3eraenser Residence 11213112014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only durinq off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 1 §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 w exempt from the 50% high efficacy requirement when: all low efficacy luminaires in thi sensor, dimmer, energy management system (EMCS), or a multi -scene programmabl luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility r manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more 1 ­ — lightin`g lin kit f Fs M n b Mi i y. tts fp dv Uim rSits r^ Etljt fi E)SW5 m 3 kitchenare.coratroUe ramal on occ controlfsyseem and r ar{'e ftly install ooms are0j§t &fd6y' d_k6Y Qad by a an 20 watts of power per linear foot of DATE BY y be pant d EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 201412-31715:17:50 ID: Page 10 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Bergenser Residence 11213112014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). ' §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. ARPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201412-31715:17:50 ID: Page 11 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Bergenser Residence Date 12/31/2014 System Name HVAC-1 Floor Area 1,549 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 2,001 35,194 Return Vented Lighting 0 Return Air Ducts 2,984 Return Fan 0 Ventilation 0 0 Supply Fan 1,675 Supply Air Ducts 2,984 TOTAL SYSTEM LOAD 1 42,838 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 75,000 1,705 706 32,134 Total Output Btuh 75,000 Output Btuh/s ft 48.4 2,283 Cooling System 0 Output per System 47,500 0 0 0 Total Output Btuh 47,500 1,705 -1,675 Total Output Tons 4.0 2,283 Total Output Btuh/s ft 30.7 Total Output s ft/Ton 391.3 35,025 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Existing 4 t HVAC.. 37,893 3,922 75,000 Airflow cfm/s ft 1.03 Airflow cfm/Ton 404.2 Outside Air % 0.0 % Total Adjusted System Output 37,893 3,922 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM 75,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 113 OF 114 OF t Heating Coil Supply Fan ° 1,600 cfm 112 F ROOM _ _ 70 OF CITY OF II COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak jj .. _ ° 112/78°F Outside Air Ar 0 cfm 80 / 64 OF dw 80/64°F 57/56°F 58/57°F P '' " t ROVED ' « NSTRUCTION Cooling Coil Supply Fan SATE— ---- BY-60-a7 57 °F 1,600 cfm ..................... 46.4% ROOM 78164 OF EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 201412-31T15:17:50 ID: Page 12 of 17 ROOM LOAD SUMMARY Project Name Date Bergenser Residence 12/31/2014 HVAC -1 1,7051 706 32,134 1,549 ROOM LOAD SUMMARY 706 32,134 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Existing Res. Existing Res 1 1,129 21,432 1,669 1,129 21,432 1,669 542 24,417 Addition 1 872 13,762 36 872 13,762 36 164 7,717 PAGE TOTAL TOTAL* I * Total includes ventilation load for zonal 2,001 35,194 1,7051 706 32,134 2, 001 , 35,194 1,7051 706 32,134 EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2014-12-31T15:17.50 ID: Page 13 of 17 1 ROOM HEATING PEAK LOADS Project Name Bergenser Residence Date 12/31/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Res Floor Area 1,513.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 0.0490 X AT °F Btu/hr 44 = 3,262 44 = 5,222 44 = 1,584 44 = 90 44 = Z552 44 = 1,725 44 = 475 44 = 5,332 = = = = = = = = = = = = _ LA R. SAFETY E$ . R OkPq& l 20,242 /60] X 44 = 4,175 BY DT Default Roof Prior to 1978 1,513.0 X R-11 Wall 1,079.0 X X X X X X X X X 0.1100 X 0.4000 X 0.1020 X 1.4500 X 0.4900 X Double Tinted FD 90.0 R-13 Wall 20.0 Wood Door 40.0 Fleetwood Norwood 3000 80.0 Double Tinted 24.0 0.4500 X Slab -On -Grade perim = 166.0 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 1,513 X Area Ceiling i t I I Y Q1- 1 LiUil_U I`X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room A P P 4 FOR CONSTRUCTION 10.30 X 0.343 Height)ATF ACH TOTAL HOURLY HEAT LOSS FOR ROOM 24,417 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-12-31715:17.50 ID: Page 14 of 17 ROOM HEATING PEAK LOADS Project Name Bergenser Residence Date 12/31/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Floor Area 36.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 36.0 X U-Value oT *F Btu/hr 0.0310 X 42 = 47 0.1020 X 42 = 728 0.4900 X 42 = 6,174 0.7300 X 42 = 675 X = X = X X = X = X = X X = X = X = X = X X = X = X = X = X = X = X = X = X = X = X X = X_ _ CII YX .)r LA Q INTA u u i L X G g&SAFl,ETYr DEPT. another room A F P Page O, [0I 7,624 I FOR CONSTRUCTION 10.30 X 1 0.337 / 60 ] X 1 42 = 93 Height pATEACH B1r OT R-30 Roof Attic R-13 Wall 170.0 X X X Fleetwood Norwood 3000 300.0 Slab-On-Grade perim = 22.0 X X X X X X X X X X X X X X X X X X X X ' X X X X X1-= X X through an interior surface to X 36 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 7,717 EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2014-12-31715:17:50 ID: Page 15 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bergenser Residence 12/31/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Res Outdoor Dry Bulb Temperature 112 OF Floor Area 1,513.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dr Bulb Temperature 78 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr Default Roof Prior to 1978 (N) 1,513.0 X 0.0490 X 56.0 = 4,152 R-11 Wall (N) 346.0 X 0.1100 X 23.0 = 875 R-13 Wall (NE) 20.0 X 0.1020 X 29.0 = 59 R-11 Wall (E) 231.0 X 0.1100 X 33.0 = 839 Wood Door (E) 40.0 X 1.4500 X 33.0 = 1,914 R-11 Wall (S) 396.0 X 0.1100 X 26.0 = 1,133 R-11 Wag (W) 106.0 X 0.1100 X 33.0 = 385 X X = X X = Page Total 9,356 Items shown with an asterisk (') denote conduction through an interior surface to another room. t. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window-Alt (N) 0.0 X 21.0 + 50.0 X 21.0 = 1,049 Window-Alt (NE) 0.0 X 21.0 + 40.0 X 32.2 = 1,290 Window Alt. (E) 0.0 X 22.8 + 80.0 X 43.6 = 3,485 Window-Alt (W) 0.0 X 22.0 + 24.0 X 42.8 = 1,026 X + X - X + X - X + X - X + X - X + X - Page Total 6,851 Internal Gain Btu/hr Occupants 3.0 Occupants X 230 Btuh/occ. = 690 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 93.69 X 34 = 2,935 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM j ,, 1,432 UI- NTA Latent Gain BUILDING & SAFETY D o to hr Occupants 3.0 Occupants X I 200 IBtuh/o¢i b -- ®v r= 600 FOR CONSTRUCTIO Infiltration: 4,771 X 0.87 X 93.69 X 0.00276 = 1,069 Air Sensible CFM ELA AW I DATE TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -J1 669 EnemyPro 5.1 by Ener Soft User Number. 6712 RunCode: 2014-12-31T15:17:50 ID: Pae 16 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bergenser Residence 12/31/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 36.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF O a ue Surfaces Orientation Area U-Factor CLTD' Btu/hr R-30 Roof Attic (N) 36.0 X 0.0310 X 56.0 = .62 R-13 Wall (E) 120.0 X 0.1020 X 33.0 = s 404 R-13 Wall (S) 30.0 X 0.1020 X 26.0 = 80 R-13 Wall (Kq 20.0 X 0.1020 X 33.0 = 67 X X = X X = X X = X X = X X = Page Total 613 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window-New W 0.0 X 22.8 + 210.0 X 43.6 = 9,149 Window-New (W) 0.0 X 22.8 + 90.0 X 43.6 = 3,921 X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 13,070 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 2.23 X 37 = 78 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM ' _" " ` 93,762 S Latent Gain ' ROVEL. Btu/hr Occupants 0.0 Occupants X 2d6 ,Btuh/oe8,.ISTRUC1 iw, 0 Infiltration: 4,771 X 0.89 X 2.23 X 36 Air Sensible CFM ELA AW BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 36 EnemvPro 5.1 by Ener Soft User Number: 6712 RunCode: 2014-12-31T15:17.50 ID: Pae 17 of 17 BUILDING ENERGY ANALYSIS REPORT 1 PROJECT: Bergenser Residence 77-153 Calle Mazatlan ` La Quinta, CA 92253 Project Designer: Stracts Architects- 550 rchitects550 S. Oleander Street ` Ppalm Springs, CA 92262 (760) 636-8951 Report Prepared by: •' Tim Scott Scott Design and,Title 24, Inc,', 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 y , REC-"'EIVE . '.Job Number: .JAN 2015 OF QUINTA CITY OF LA .':.SAFETY DEPT, QUINTA ''kRiO\/ CUfvSTRU E( OMMUNITY DEVELOPMENT - f '` - ' Date: CTION 12/31/2014 14T 4/ _6 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and.Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Ener Soft User Number. 6712 RunCode: 201412-31715:17:50 ID: PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Bergenser Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration 11213112014 Date Project Address 77-153 Calle Mazatlan La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,549 Addition 36 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 1,513 Existing Wall Wood Framed R-11 1,079 Existing Wall Wood Framed R-13 20 Altered Door Opaque Door None 40 Existing Slab Unheated Slab -on -Grade None 1,513 Perim = 166' Existing Roof Wood Framed Attic R-30 36 New Wall Wood Framed R-13 170 New Slab Unheated Slab -on -Grade None 36 Perim = 22' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (N) 15.0 1.190 0.68 none none Bug Screen Removed Right (N) 50.0 0.400 0.35 none none Bug Screen Altered Right (NE) 40.0 0.400 0.35 none none Bug Screen Altered Front (E) 80.0 0.490 0.35 none none Bug Screen Altered Front (SE) 16.0 1.190 0.68 none none Bug Screen Removed Left (S) 24.0 1.190 0.68 none none Bug Screen Removed Rear (169 24.0 0.450 0.35 none none Bug Screen Altered Rear (149 160.0 1.190 0.68 none none Bug Screen Removed Rear (1/10 300.0 0.490 0.35 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Packaged Air Condition 12.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by EnergySoft User Number- 6712 RunCode: 201412-31T15:17:50 ID: Page 3 of 17 I 1 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Bergenser Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 11213112014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation; and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. { r t HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. ~ OF LA QUINTA I RI III nm 1G &SAFE' r,` P . OEPT. I FORCONSTRUCTION ' R1TF RY Ene Pro 5.1 b Ene Soft - User Number. 6712 RunCode: 2014-12-31715:17:50 ID: Page 4 of 17 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name. Building Type m Single Family ❑ Addition Alone Date Bergenser Residence . ❑ Multi Family m Existing+ Addition/Alteration 12/31/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 16.05 12.75 3.30 Space Cooling 164.68 150.72 13.96 Fans 36.62 32.95 3.68 Domestic Hot Water 14.55 14.55 0.00 Pumps 0.00 0.00 0.00 Totals 231.90 210.97 20.94 Percent Better Than Standard: 9.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: too (E) 471 80 Fuel Available at Site: Natural Gas (S) 426 0 Raised Floor Area: o (1/109 450 324 Slab on Grade Area: 1,549 (N)• 456. 90 Average Ceiling Height: 10.3 Roof 1,549 0 Fenestration Average U -Factor: 0.47 TOTAL: 464 Average SHGC: 0.35 Fenestration/CFA Ratio: 31.9 REMARKS The Hideaway STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed ' to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Com an Scott Design and Title 24, Inc, P Y Address 77-085 Michigan Drive Name Tim Scott 12/31/2014 City/State/ZiD Palm Desert, Ca 92211 Phone (760) 200-4780 Si ne..d .ate The individual with overall design responsibility hereby certifies that the proposed building design %eaes` t of ff yrs t of construction documents is consistent with the other compliance forms and workshelet witfitb e peitiQnC, a td with any other calculations submitted with this permit application, and recognizes that cbm"plia ee ysyg uct_c_{esigii; duct sealing, verification of refrigerant charge, insulation installation quality, and buildin`enve odd sealiigi ire installer testing and certification and field verification by an approved HERS rater. rf C;b# STRUCTION Designer or Owner (per Business & Professions Code) `:' DATE _ BY Company Stracts Architects . Address 550 S. Oleander Street Name Anton Marinkovich City/State/Zip Ppalm Springs, CA 92262 Phone (760) 636-8951 Signed License # Date EnemvPro 5.1 by EnemySoft User Number.' 6712 RunCode: 2014-12-31T15:17:50 ID: Page 5 of 17 r CERTIFICATE OF COMPLIANCE:. Residential Part 4 of 5) CF -1 R Project Name i Building Type '121 Single Family ❑ Addition Alone Date Bergenser Residence' f .' ❑ Multi Family m Existing+ Addition/Alteration 2/31/201 OPAQUE SURFACE DETAILS Surface U- - Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm . Tilt Status 4 Location/Comments Roof 1,513 0.049 R-19 0 •20 Existing 4.2.1-A4 Existing Res. Wall 25 0.110 R-11 0 90 Remove 4.3.1-A2 Existing Res. Wall 346 0.110 R-11 0 90 Existing4.3.1-A2 Existing Res. Wall 20 0.102 R-13 45 90 Altered 4.3.1-A3 E=4.3.1 -A2 Existing Res. Wall 231 0.110 R-11 90 90 Existing4.3.1-A2 Existing Res. Door 40 1.450 None 90 . 90 Existing4.5.1-Al. Existing Res. Wall 90 0.110 R-11 90 .90 Remove 4.3.1-A2 Existing Res. Wall -20 0.110 R-11 135 90 Remove 4.3.1-A2 - Existing Res. Wall 396 0.110 R-11 180 90 Existing4.3.1-A2 ExistingRes. Wall 26 0.110 R-11 180 90 Remove 4.3.1-A2 -,. Existing Res. Wall 106 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Res. Wall 100 0.110 R-11 270 90 Remove 4.3.1-A2 ExistingRes. Slab 1,513 0.730 None 0 180 Existing4.4.7-A1 ExistingRes. Roof 36 0.031 R-30 01, 0 New • 4.2.1-A20 - ExistingRes. Wall 120 0.102 R-13 90 90 New 4.3.1-A3 Existin Res. - Wall 30 0.102 R-13 180 90 New 4.3.1-A3 Existing Res. " FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status GlazingType, Location/Comments 1 Window. 15.0 1.190 Default 0.68 Default 0 Removed Single Metal Tinted Existing Res. 2 Window 50.0 0.400 NFRC 0.35 NFRC 0 Altered Double Tinted FD Existing Res. 3 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 4 Window 40.0 0.400 NFRC 0.35 NFRC 45 Altered Double Tinted FD Existing Res. 5 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 6 Window 80.0 0.490 NFRC 0.35 NFRC 90 Altered Fleetwood Norwood 3000 Existing Res. 7 Existing 1.190 Default 0.68 Default Single Metal Tinted pre -altered for above 8 Window 16.0 1.190 Default 0.68 Default 135 Removed Single Metal Tinted • - Existing Res. 9 Window 24.0 1.190 Default 0.68 Default 180 Removed Single Metal Tinted •' Existing Res. 10 Window 24.0 0.450 NFRC 0.35 NFRC 270 Altered Double Tinted Existing Res. , 11 Existing 1.190 Default 0.68 Default Single Metal Tinted pre -altered for above 12 Window 64.0 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Res. 13 Window 96.0 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Res. 14 Window 210.0 0.490 NFRC 0.35 NFRC 270 New Fleetwood Norwood 3000 Existing Res. , 15 Window 90.0 0.490 NFRC 0.35 NFRC 270 New Fleetwood Norwood 3000 Existing Res. (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window OverhangLeft Fin -Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len • H t LExt RExt Dist . Len H t Dist Len H t 1 Bug Screen - 0.76 2 Bug Screen 0.76 , 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 I i Z­­ t- 6 Bug Screen 0.76 ( R i III ! i ( R. 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen 0.76 ( i 10 Bu Screen 0.76 11 . Bu Screen 0.76 i 12 Bug Screen 0.76 , ' )ATE _ B 13 Bug Screen 0.76 - 14 Bug Screen 0.76 15 Bug Screen 0.76 - - • 9L .. Ene Pro 5.1 b EnergySoft User Number: 6712 RunCode: 2014-12-31715:17:50 • " ID: Page 6 of 17 r CERTIFICATE OF COMPLIANCE:. Residential Part 4 of 5) CF -1 R Project Name i Building Type '121 Single Family ❑ Addition Alone Date Bergenser Residence' f .' ❑ Multi Family m Existing+ Addition/Alteration 2/31/201 OPAQUE SURFACE DETAILS Surface U- - Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm . Tilt Status 4 Location/Comments Roof 1,513 0.049 R-19 0 •20 Existing 4.2.1-A4 Existing Res. Wall 25 0.110 R-11 0 90 Remove 4.3.1-A2 Existing Res. Wall 346 0.110 R-11 0 90 Existing4.3.1-A2 Existing Res. Wall 20 0.102 R-13 45 90 Altered 4.3.1-A3 E=4.3.1 -A2 Existing Res. Wall 231 0.110 R-11 90 90 Existing4.3.1-A2 Existing Res. Door 40 1.450 None 90 . 90 Existing4.5.1-Al. Existing Res. Wall 90 0.110 R-11 90 .90 Remove 4.3.1-A2 Existing Res. Wall -20 0.110 R-11 135 90 Remove 4.3.1-A2 - Existing Res. Wall 396 0.110 R-11 180 90 Existing4.3.1-A2 ExistingRes. Wall 26 0.110 R-11 180 90 Remove 4.3.1-A2 -,. Existing Res. Wall 106 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Res. Wall 100 0.110 R-11 270 90 Remove 4.3.1-A2 ExistingRes. Slab 1,513 0.730 None 0 180 Existing4.4.7-A1 ExistingRes. Roof 36 0.031 R-30 01, 0 New • 4.2.1-A20 - ExistingRes. Wall 120 0.102 R-13 90 90 New 4.3.1-A3 Existin Res. - Wall 30 0.102 R-13 180 90 New 4.3.1-A3 Existing Res. " FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status GlazingType, Location/Comments 1 Window. 15.0 1.190 Default 0.68 Default 0 Removed Single Metal Tinted Existing Res. 2 Window 50.0 0.400 NFRC 0.35 NFRC 0 Altered Double Tinted FD Existing Res. 3 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 4 Window 40.0 0.400 NFRC 0.35 NFRC 45 Altered Double Tinted FD Existing Res. 5 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 6 Window 80.0 0.490 NFRC 0.35 NFRC 90 Altered Fleetwood Norwood 3000 Existing Res. 7 Existing 1.190 Default 0.68 Default Single Metal Tinted pre -altered for above 8 Window 16.0 1.190 Default 0.68 Default 135 Removed Single Metal Tinted • - Existing Res. 9 Window 24.0 1.190 Default 0.68 Default 180 Removed Single Metal Tinted •' Existing Res. 10 Window 24.0 0.450 NFRC 0.35 NFRC 270 Altered Double Tinted Existing Res. , 11 Existing 1.190 Default 0.68 Default Single Metal Tinted pre -altered for above 12 Window 64.0 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Res. 13 Window 96.0 1.190 Default 0.68 Default 270 Removed Single Metal Tinted Existing Res. 14 Window 210.0 0.490 NFRC 0.35 NFRC 270 New Fleetwood Norwood 3000 Existing Res. , 15 Window 90.0 0.490 NFRC 0.35 NFRC 270 New Fleetwood Norwood 3000 Existing Res. (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window OverhangLeft Fin -Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len • H t LExt RExt Dist . Len H t Dist Len H t 1 Bug Screen - 0.76 2 Bug Screen 0.76 , 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 I i Z­­ t- 6 Bug Screen 0.76 ( R i III ! i ( R. 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen 0.76 ( i 10 Bu Screen 0.76 11 . Bu Screen 0.76 i 12 Bug Screen 0.76 , ' )ATE _ B 13 Bug Screen 0.76 - 14 Bug Screen 0.76 15 Bug Screen 0.76 - - • 9L .. Ene Pro 1 • • rm , - / • Project Name Residence Building Type 0 Single Family 0 Multi Family ■ Addition 10 Existing+ Addition/Alteration OPAQUEBergenser ! Joint Appendix 4 Location/Comments FENESTRATION SURFACE DETAILS Location/Comments EXTERIOR SHADING DETAILS Exterior Shade Type