Loading...
PAT (07-1118)55615 Medallist Dr 07-1118 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 plication Number _ -07700001P118' perty Address: 55615 MEDALLIST DR APN: 767-510-012- - - Application description: PATIO COVER - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 14830 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: TAPPEY RESIDENCE 55-615 MEDALIST DR. LA QUINTA, CA 92253 (760)393-8715 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: ' 4/16/07 Contractor: Applicant: Architect or Engineer: PRECISION PATIOS I 67210 KANN ROAD Ln] DESERT HOT SPRINGS, CA 41 N (760)413-2007 APR 162007 Lic. No.: 539152 CITY OF LA QUINTA FINANCE DEPT. ——————-----——----—---------------------—----------------————-—------——-------=—--------—------——- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I have and will maintain a certificate of consent to self -insure for'workers' compensation, as provided License Class: C47 D03 License No.: 539152 for'by Section 3700 of the Labor Code, for the performance of the work for which this permit is ((( issued. t Date: 1 C) r-ContracEoi: _ I have and will maintain workers' compensation insurance, as required by Section 3700ofthe Labor --'" - - ---" Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EXEMPT Policy Number EXEMPT following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant.for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 00 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the'applicant to a civil penalty of not more than. five hundred dollars ($500).: Dat Applicant: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and n the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a :permit subject to the - 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. _ Each person upon whose behalf this, application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt, under Sec. - - , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPEINIIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. - - I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cou to enter upon the above-mentioned property for inspection purposes. Date- Signature (Applicant nt : ' Application Number . . .07-00001118 Permit PATIO COVER PERMIT • Additional desc . " PermitFee*162.00 Plan Check 'Fee '105.30 Issue Date Valuation 14830 Expiration Date 10/13/07' Qty Unit Charge. Per Extension BASE FEE 45.00 13.00; 9.0000 THOU BLD6-2,001-25,0'00 117.00. Permit ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 15.00 Plan Check Fee 3.75 Issue Date . . . Valuation 0 Expiration Date 10/13/.07 Qty Unit Charge Per Extension BASE FEE 15.00 --------------------------------------------------- 7 -------------- ----------------------------------------- Special Notes and.Comments Special ---------- .1115' ALUMAWOOD LATICE PATIO COVER PER APPROVED PLAN. 36" COURTESY BLOCKWALL • Fee summary Charged Paid Credited Due -- - - - - -- - - - - - - - ------ - - - - -- •---- - - - - ------ - - - Permit Fee Total 177.00 .00 - -- .00 ---- - - - - - - 177.00 Plan Check Total 109.05 .00 .00 109.05 Grand Total '286.05 .00 00 286.05 Bin ff City of La Quetta Building U Safety Division P:O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: !S 6(S y ,E( .{,; Q- ( Owner's Name:. T A A. P. Number: Address: 4_L4 S T, D t2 Legal Description: City, ST, Zip: Q Contractor: EC40 t) h -C 0 Telephone::'1 S Address: K YZ Project Description: l r-:) City, ST, Zip:. O 2 LAVOE.MjoCopV QK- Telephone: .6 too State Lie. # : Arch., Engr., Designer: City Lic. #•in Address:. City., ST, Zip: Telephone: State Lid.. #: SC, 5 — Name of Contact Person:. Construction Type: Occupancy: Project type (circle one): New Add'n . Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: . APPLICANT: DO NOT WRITE BELOW THIS UNE # Sabmittal. Req'd Recd TRACKING . PERMIT FEES -Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan. Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan. Plans resubmitted Mechanical Grading.plan2n°.Review, ready for corrections/issue Electrical Subcontactor List Galled Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, ready for correctionstissue. Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees t. . i rc co FAIRWAYS ASS®CIATI®N t April 16, 2007 Mr. & Mrs. Richard Tappet 16055 Meadowcrest Road Sherman Oaks CA 91403 Re:, 55-615 Medallist Drive Architectural Application - Alumawood Awning & Wall .Dear Mr. & Mrs. Tappey After review of the revised plans per the requirements set forth by the Architectural Committee, the committee has given its approval for the installation of the alumawood. awning and wallat the, above property. R If you should have any questions, please do not hesitate to contact the Association office at anytime. - Sincerely, , PGA WESTFairreu)aAssociation The ArdWte mal Corrnr¢tt ARCWncp - Cc: Precision Patios ' File ; Post Office Box 1690 •'La.Quinta, California 92247 Phone (760) 776-5100 Fax (760) 776-5111 ER -2640P GENERAL NOTES AND SPECIFICATIONS: 1. ALUMINUM DESIGN AND STRESSES ARE PER THE 1997 EDITION OF THE UNIFORM BUILDING CODE AND THE LATEST EDITION OF THE ALUMINUM CONSTRUCTION MANUAL. 2. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL OR GREATER YIELD AND ULTIMATE STRENGTHS. 3. ALL CONCRETE SHALL HAVE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500-P.S.I. CONCRETE SLAB SHALL HAVE 3 1/2" MINIMUM THICKNESS AND SHALL BE IN GOOD CONDITION. 4. ALL FOOTINGS SHALL BEAR ON FIRM, NATURAL UN -DISTURBED SOIL OR CERTIFIED FILL. DESIGN VERTICAL SOIL BEARING PRESSURE = 1,000 P.S.F. 5. ALL STEEL MEMBERS SHALL BE HOT -DIP GALVANIZED, RUST-O-LEUM OR EQUAL PAINTED OR ELECTROPLATED AND CONFORM TO A.S.T.M. A-446, GRADE C, UNLESS OTHERWISE NOTED. 6. ALUMINUM FASTENERS SHALL BE 2024-T4. ALL OTHER FASTENERS SHALL BE GALVANIZED STEEL, CADIUM OR ZINC PLATED. ALL BOLTS SHALL CONFORM TO A.S.T.M. A-307 AND HAVE STANDARD CUT PLATE WASHERS. HOLES FOR BOLTS SHALL BE BOLT DIAMETER PLUS 1/16" MAXIMUM. 7, EXPANSION BOLTS SHALL BE "HILTI KWIK-BOLTS" PER I.C.C. ER- 4627, RAWL DRIVE ANCHOR PER ICC ER -5225, OR EQUAL. ALL BOLTS SHALL HAVE A MINIMUM CONCRETE EDGE DISTANCE OF SIX BOLT DIAMETERS. 8. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG GIVING THE NAME AND ADDRESS OF THE MANUFACTURER, DESIGN LOADS AND ENCLOSABILITY. 9. ALL ITEMS PERTAINING TO EACH PARTICULAR INSTALLATION SHALL BE CIRCLED, I.E., PROJECT, POST SPACING, FOOTING DETAIL, ETC. 10. OPEN LATTICE PATIO COVER SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID MATERIAL, AND THE DESIGN LOADS HAVE ONLY BEEN APPLIED TO THE HORIZONTAL PROJECTION AREA OF THE LATTICE, RAFTERS, BEAM, ETC. PER I.C.C. CRITERIA. 11. FREESTANDING PATIO COVER SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID MATERIAL. 12. SOLID ATTACHED PATIO COVERS MAY BE ENCLOSED COMPLYING WITH APPENDIX CHAPTER 31, DIVISION 111, OF THE 1997 UBC. 13. THE INSTALLATION OF LAG SCREWS & WOOD SCREWS ARE REQUIRED TO BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION (NDS), SECTIONS 9.1.2 & 11.1.2. CITY OF LA QUINTA BUILDING & SAFETY DEPT. AP oRC ESD FOR C DA IIG(o sY NOTES: ALL COMPONENTS ARE INTERCHANGABLE UNLESS OTHER WISE NOTED P ESSSG. . 21543 EXP. 9-30-2007 S . CIVIL P q OF CAL\F I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11/238002 JAMES G. FOX, CIVIL ENGINEER 10, 20 & 30 psf DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE 8060 TELEGRAPH RD., DOWNEY. CA 90240 GENERALNOTES HORIZ.WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 1 O 30 REVISED BY: K.K. & D.P. 562 806-1337 FAX:927-2509 (oxen hotmail.cam 70, 90 8 110 MPH (916)452.7021 FAX 4031519 salesQdurelum.com '0°" ALUMINUM ROOF PANEL SEE SCHEDULE FOR SPANS O.H. VARIES. SEE SCHEDULE SEE DETAIL FOR SPLICE 1 1/2" SO. SCROLL POSTS 3 1/2' SLAB ATTACHMENT MAY BE USED WHERE PERMITTED. SEE SCHEDULE ATTACHMENT CHANNEL SEE DETAIL — FOOTING WHERE REQUIRED J SEE SCHEDULE FOR FOOTING CUBE SIZE ..A" ALUMINUM ROOF PANEL SEE SCHEDULE FOR SPANS OPTIONAL: O.H. VARIES, SEE SCHEDULE SEE DETAIL FOR SPLICE SO. POSTS, SIZE VARIES 3 1/2' SLAB MAY BE USED TO CONSTRAIN FOOTING, SEE SCHEDULE SOLID PATIO TYPES STRUC711 1 T Bf LF.c VARIfS NOTE: EACH COMPONENT IS INTER- CHANGEABLE WITH ANY OTHER COMPONTENT UNLESS OTHERWISE SHOWN. OF SNUC TURF VARIfS (MAYIVOTBffNCLOSED) ATTACHMENT CHANNEL ALUMINUM SEE OFrne — ROOF PANEL SEE SCHEDULE FOR SPANS O.H. VARIES, SEE SCHEDULE SEE DETAIL FOR SPLICE 1 1/2" SQ. SCROLL POSTS 3 1/2" SLAB ATTACHMENT MAY BE USED WHERE PERMITTED. J SEE SCHEDULE r FOOTING WHERE REQUIRED SEE SCHEDULE FOR FOOTING CUBE SIZE TYPE "B" ATTACHED ALUMINUM SEE SCHEDULE R T SPACING PI ROOF PANEL O -y I SEE SCHEDULE 1/p PoST SJ FOR SPANS NC SfS OPTIONAL: _6 O.H. VARIES, SEE SCHEDULE f NO. 21543 UP. 9.362007 T yf pRQI CTjON F f CS SA/Y OPTIONAL CANTILEVER SEE SCHEDULE FOR ALTERNATE:rOSPLICE rf0 7/g`III SINGLE POST SpgC/NSEE SCHEDULENOTE: AT THIS POST AND AT END BAYS NOTE: EACH COMPONENT IS INTER- CHANGEABLE WITH ANY OTHER COMPONTENT UNLESS OTHERWISE SHOWN. ­ ," OF STRUCru"6VARIfS (MAyNOTBffNCLOSfO) tfSCyfDUCfS WNVG SEE SCHEDULE R T SPACING PI SEE DETAIL FOR SPLICE O -y I OPTIONAL: CANTILEVER BEAM 1/p PoST SJ SEE SCHEDULE NC SfS SE ER JAMES G. FOX, CIVIL ENGINEER NOTE: O SPLICE OfS POST SPACING POST f ID AT END B/gS. SQ. POSTS, SIZE VARIES SCALE: NONE= P_ O.y HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 ALTERNATE: 12' 'IPA ` MAYBE (562) 806-1337 FAX:927-2509 foxeng@hotmail.00m USED SINGLE POST (916) 452-7021 FAX 403.1519 sales@dumium.0om TO CONSTRAIN SEE SCHEDULE FOOTING, SEE NOTEJO SPLICE AT THIS POST D AT END BAYS. SCHEDULE NO. 21543 UP. 9.362007 T yf pRQI CTjON F f CS SA/Y OPTIONAL CANTILEVER SEE SCHEDULE FOR ALTERNATE:rOSPLICE rf0 7/g`III SINGLE POST SpgC/NSEE SCHEDULENOTE: AT THIS POST AND AT END BAYS NOTE: EACH COMPONENT IS INTER- CHANGEABLE WITH ANY OTHER COMPONTENT UNLESS OTHERWISE SHOWN. ­ ," OF STRUCru"6VARIfS (MAyNOTBffNCLOSfO) tfSCyfDUCfS WNVG SEE SCHEDULE R T SPACING PI FOX ENGINEERING INC. O -y I ALTERNATE: SINGLE POST 1/p PoST SJ SEE SCHEDULE REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER NOTE: O SPLICE HS DURALUM PRODUCTS, INC. POST f ID AT END B/gS. FOOTING WHERE REQUIRED -1 FOOTING WHERE REQUIRED __/ SEE SCHEDULE FOR FOOTING CUBE SIZE SEE SCHEDULE FOR FOOTING CUBE SIZE NOTE: EACH COMPONENT IS INTER - 1/2 x 9' STEEL ROD NOTE: EACH COMPONENT IS INTER- 1/2 x 9' STEEL ROD CHANGEABLE WITH ANY OTHER CHANGEABLE WITH ANY OTHER COMPONTENT UNLESS OTHERWISE SHOWN. COMPONTENT UNLESS OTHERWISE SHOWN. TYPE "C" FREESTANDING W/CANTILEVER OPTION TYPE "D" FREESTANDING MULTISPAN W/CANTILEVER OPTION NMI I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER 10, 20 8 30 psi DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE= 8060 TELEGRAPH RD., DOWNEY. CA 90240 HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 2 OF 30 REVISED BY: K.K. 8 D.P. (562) 806-1337 FAX:927-2509 foxeng@hotmail.00m 70, 90 8 110 MPH (916) 452-7021 FAX 403.1519 sales@dumium.0om RAFTER.SEETABLE FOR SIZE AND SPACING MAX. PROD. SEESCHEDULE MAX O.H. / U- SEE SCHEDULE � SEE LENGTH OF STRUCTURE VARIES NOTE: EACH COMPONENT IS INTER- I CHANGEABLE WITH ANY OTHER COMPONTENT UNLESS OTHERWISE SHOWN. OPEN LATTICE -TYPE PATIO COVER SCALE NTS TYPE "E" ATTACHED SINGLE SP MAX. PROD. / SEESCHEDULE RAFTER.SEETABLE FOR SIZE AND SPACING HEIGHT LENGTH OF STRUCTURE VARIES OPEN LATTICE TYPES gTsry� p E- TAIL 3 i? SLAB ATTACHMENT MAY BE USED WHERE PERMITTED. SEESCHEDULE FOOTING WHERE REQUIRED, SEE SCHED. FOR FOOTING CUBE SIZE NOTE: THIS OPEN LATTICE -TYPE STRUCTURE MAY NOT BE ENCLOSED. NOTE: THIS OPEN LATTICE -TYPE STRUCTURE N MAY NOTBE ENCLOSED. I� SEE POST DETAIL. T�4w NOTE: EACH COMPONENT IS INTER- 3Irr SLAB CHANGEABLE WITH ANY OTHER y, MAY BE USED T TO CONSTRAIN COMPONTENT UNLESS OTHERWISE SHOWN. FOOTING SEE SCHEDULE OPEN LATTICE -TYPE PATIO COVER FOOTING WHERE REOUIRED SCALE: NTS SEE SCHED. FOR FOOTING CUBE SIZE TYPE "G" FREESTANDING SINGLE SPAN LATTICE STRUCTURE HEIGHT LENGTH OF STRUCTURE VARIES MAX. PROD. POST WITH SIDE- SEE SCHEDULE NOTE: THIS OPEN LATTICE -TYPE STRUCTURE MAY NOTBBE ENCLOSED. NOTE: EACH COMPONENT IS INTER- RAFTER. SEETABLE 31I2'SLABATTACHMENT CHANGEABLE WITH ANY OTHER FCR SIZE MAY BE USEWHERE COMPONTENT UNLESS OTHERWISE SHOWN. - AND SPACING SEE SCHEDULE ONE HEIGHT LENGTH OF STRUCTURE VARIES RAFTER.SEETABLE FOR SIZE AND SPACING HEIGHT LENGTH OF STRUCTURE VARIES POST CRC SEE POST 317 SLAB POST WITH SIDE- $ra MAY BE USED S PLATESEED it NOTE: EACH COMPONENT IS INTER- TO CONSTRAIN 31I2'SLABATTACHMENT CHANGEABLE WITH ANY OTHER 90 MAY BE USEWHERE COMPONTENT UNLESS OTHERWISE SHOWN. r SEE SCHEDULE ONE SEE SCHED. FOR FOOTING CUBE SIZE FOOTING WHERE REQUIRED. 3S!. -- TYPE "F" ATTACHED m r, 21543 m 530-2007 P # MAX. PROD. CIVIL a SEESCHEDULE MULTISPAN SEE SCHED. FOR FOOTING CUBE SIZE LATTICE STRUCTURE NOTE: THIS OPEN LATTICE -TYPE STRUCTURE MAY NOT BE ENCLOSED. n RAFTER.SEETABLE FOR SIZE AND SPACING HEIGHT LENGTH OF STRUCTURE VARIES POST CRC SEE POST I.C.C. E.S. EVALUATION 317 SLAB FOX ENGINEERING INC. MAY BE USED NOTE: EACH COMPONENT IS INTER- TO CONSTRAIN S�� CHANGEABLE WITH ANY OTHER %q JAMES G. FOX, CIVIL ENGINEER FOOTING. SEE SCHEDULE COMPONTENT UNLESS OTHERWISE SHOWN. DURALUM PRODUCTS, INC. FOOTING WHERE REQUIRED ER -2640P ONE SEE SCHED. FOR FOOTING CUBE SIZE TYPE "H" FREESTANDING MUI TISPAN I A IC:F STRI IC:TI IRF I.C.C. E.S. EVALUATION Y: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: 1 ] REPORT NUMBER 2 312 0 0 2 FREVISEDBY:K.K.&D.P. JAMES G. FOX, CIVIL ENGINEER 10, 20 8 30 ps1 DURALUM PRODUCTS, INC. SHEET ER -2640P ONE X 8060 TELEGRAPH RD., DOWNEY, CA 90240 HORIZ. WIND = 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 3 OF 30 (562) 806.1337 FAX:927-2509 Ioxeng@hotmail.mm 70, 90 8 110 MPH FAX 4031519 sales@dumlum.mm ..4 1.. PANEL SPANS AND OVERHANG FOR PATIO STRUCTURES 70/90/110 MPH 12' HEIGHTS .25" .6T' T=SEE TABLE BELOW A.35"O 40" 75I — 77 .09R. (I.S.) 25" .67" I_ FT MA ` ALL UNMARKED RADII.06R ,25• (, ° 0" 2.5' _ c 246" 2rJ'I 45 N T=SEETA9LE BELOW 40"TYP. 36" ,.,2s 40 5"1.48' - .7s- -.75- 3.00" -- 4.50" 4.50" 4.50" , 7.25" 24.00 0 ALUM. ALLOY 3004-H36 OR EQUAL ALUM. ALLOY 3004-H36 OR EQUAL ALUM. ALLOY 3004-H36 OR EQUAL 24"TRI='V"PAN 8"X2 1/2" FLAT PAN W/(2) -V'S 12" x 3 1/2" W PANEL L.L.= PANEUT' 70 MPH 90 MPH 110 13'-6" 'T' 70 MPH 90 MPH 110 MPH 'T' 70 MPH 90 MPH 110 MPH (PSF) (IN.) SPAN O.H. SPAN O.H. SPAN (IN•) SPAN O.H. SPAN O.H. SPAN O.H. (IN.) SPAN O.H. SPAN O.H. SPAN O.H. 10 .018 12,_1„ 4'-U' 12,_1„ 4,-0" 8'-0" .020 12,_10„ 4'-2" 10'-5" 3'-T' 8'4" 2'-11" .020 15,_9„ 5'-0" 12,_9„ 4'S" 10,_3„ 3'-T' .024 15,-(y, 5,_2„ 14,-0„ 4,$„ 9,-0„ .024 14,_1„ 4'-T' 13,_2„ 4,4„ 101_7„ 3,$„ .024 19,-0„ 6'-0„ t5,_7„ 51_51 12,-0„ 4,4" .032 17'-0" 5.11„ 17,_0„ 5'-8" 10'-0" .032 15,_5, 5'-1" 15'-S' 5'-1" 15,-01' 4'-11" .032 20'-0" T_7, 14,_9„ 5,_1„ 12,_2„ 4,_3„ .040 16,_7„ 5,_5„ 16,_7„ 5,_5„ 16,_5„ 5'_5„ .040 22,-9" 7'-11„ 16,_5„ 51-9" 13,_6„ 4,$„ 20 .018 9,_2„ 3'4" 8'-9" 3,-0" 8'-0" 2'4" .020 9'-10" 3'-2" 9'-10" 3'-2" 8'4„ 2'-9" .020 12'-0" 4'-2" 12W' 4'-2" 12'-0" 4'-2" .024 101-81, 3'-8" 10'4„ 3'4„ 9'4" 3'-0" .024 11.3" 3'$' 11.3„ 3'-8" 10'-T' 3'-5" .024 14'-0' 4'-10" 14'-0" 4'-10" 14'-0" 4'-10" .032 13'-3" 4'-6" 11'-9" 3'-8" 10'-0" 3'-6" .032 12'-4" 4'-0" 12'-4" 4'-0" 12'4" 4'-U' .032 16'-0" 5'-T' 16'-0" 5'-T' 16'-0" 5'-T' .040 13'-3" 4'-4" 13'-3" 4'4" 13'-3" 4'4" .040 1T-0" 5'-11" 17'-0" 5'-11" 1T-0" 5-11„ 30 .018 7,-0„ 2,_6„ 7,-0„ 2,$„ 8'-01, 2,_6„ .020 8,_1„ 2,$„ 8,_1„ 2,_8„ 61_11, 2,$„ .020 10,-0„ 3,-0„ 101-0" T-6" 10'-0„ X-6' .024 9'-0' 3'-O" 9'-0" 2'-11" 9'-0" T -O" .024 9'4" T-1" 94" 3'-1" 9'4" 3'4" .024 12'-0" 4'-2" 12'-0" 4'-2" 12'-0" 4'-7' .032 10'-10" 3'-8" 10'-10" 3'-9" 10'-0" 3'-6" .032 10'-10" 3'-T' 10'-10" 3,-T' 10'-10" 3'-T' .032 14' 0 4'-10 14'-0" 4'-10" 12'-6" 4'4" Q- MES G.F 9 sP + .040 11,-8„ 3'-10" 11' 8" 3'-10„ 111_61, 3'-10" .040 1q' 6" g_1„ 14,_6„ 5.1„ 14 6„ 5.1„ i 9-762007 c OF CALfoe I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 1123/2002 JAMES G. FOX, CIVIL ENGINEER 10, 20 8 30 psl DURALUM PRODUCTS, INC. SHEET. ER -2640P SCALE:NONE - 8060 TELEGRAPH RD., DOWNEY. CA 90240 PANEL SPANS 8269 ALPINE AVE., SACRAMENTO, CA 95826 40F 30 REVISED BY: K.K. 8 D.P.10 (562) 806-1337 FAX:927.2509 foxengQhotmail.mm 70, 90 8 110 MPH (916) 452-7021 FAX 4031519 setes@duralum.mm .,oe w. cvvim, PANEL FASTENERS 70/90/110 MPH .750" 24" 300" 24" TRI -'V" PAN .240" .075' L.L.= PSF 70- MPH 90- MPH 110- MPH 10 #8 S.M.S. #10 S.M.S. #10 S.M.S. 20 #10 S.M.S. #10 S.M.S. #12 S.M.S. 30 #12 S.M.S. #12 S.M.S. #12 S.M.S. SKYLIGHT DETAIL 12" X 3 1/2" W PANEL L.L.= PSF 70- MPH 90- MPH 110- MPH 10 #8 S.M.S. #10 S.M.S. #10 S.M.S. 20 #10 S.M.S. #10 S.M.S. #12 S.M.S. 30 #12 S.M.S. #12 S.M.S. #12 S.M.S. NOTE: FASTENERS INDICATED ARE TO BE USED AT FRONT HEADER AND REAR LEDGER .075" 12' HEIGHTS .860" 40" 6.00" R9.250 OPTIX® PRODUCTS ACRYLIC PER 1 I.C.C. E.R. 5411 OR EQUAL QaOFEssla µES G. p 4iZc m NO. 21543 EXP. 9-30-2007 p # O SKYLIGHT PANELS "reoFCAlJf P SCHEDULE OF ALLOWABLE SPANS FOR 8"x 2 1/2" FLAT PANEL ADJACENT T L.L.= 8" PANEL SPANS t=.020" t=.024" t=.032" t=.040" 10 10'-2" 12'-9" 13'-4" 14'-7" 20 8'-10" 10'-3" 11'-4" 12'-3" 30 7'-1" 8'-4" —F— 9'-10" 10'-8" USE A MAX. OF (1) SKYLIGHT PANEL PER (3) 8" ROOF PANELS 8,00" L.L.= PSF 70- MPH 90- MPH 110- MPH 10 #8 S.M.S. #10 S.M.S. #10 S.M.S. 20 #10 S.M.S. #10 S.M.S. #12 S.M.S. 8"x2 1/2" FLAT PAN W/(2) -V'S 30 #12 S.M.S. #12 S.M.S. #12 S.M.S. I.C.C. E.S. EVALUATION DRAWN BY: K.K. -- ... FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER 10, 208 30 psf DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE:NONE $ 8060 TELEGRAPH RD.,DOWNEY, CA 90240 PANEL FASTENERS HORI2. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 50F 30 I REVISED BY: K.K. 8 D.P. 562 806-1337 FAX:927-2509 foxen 0holmail.mm 70, 90 8 110 MPH (916) 452-7021 FAX 4031519 sales@duralum.com "'"o' cmz W' RAFTER SPANS AND OVERHANG FOR OPEN LATTICE PATIO STRUCTURES 70/90/110 MPH 12' HEIGHTS .5ALUM. ALLOY 3004-H36 I 6.5- 1 1 .• 2, 6' OR EQUAL . MAX.. 2' • • x--,.{ 3.0' ypF ESSION ALUM. ALLOY 3004-1-136 'P1tES C F + c OR EQUAL .042' ALUM. ALLOY 3004H36 .024'x_024' NO. 21543 m OR EQUAL .032' - .032' EXP. 9a0-2007 A sr 0 m% - 2 t2 x 61/2" RAFTER DBL. 2 x 6 1/2" RAFTER 3 x 8" RAFTER Ll = RAFTER'T' 16" O.C. 24" O.C. 'T' 16" O.C. 24" O.C. 'T' 16" O.C. 24" O.C. (PSF) (IN.) SPAN O.H. SPAN O.H. (IN.) SPAN O.H. SPAN O.H. (IN.) SPAN O.H. SPAN O.H. .024 15-0" 4V' 14'--0" 4'-0" .024 21'_0" 4'-0 17'-0" 4'-0" .042 21'-0" 4'-0" 21'-0" 4'-0" 10 .032 19;-0" 4,-0„ 181-01, 4,-0„ .032 21,-0" 4--0", 20,-2„ 4'-0 024 10'-8" 3'-8" 9-0" 3'-0" .024 ' 14'-0" 4'-0" 12'-3" 4'-0" .042 19'-6" 4'-0" 1T-1" 4'-0" 20 , .032 14,-0„ 4,-0" 12'-1" 4'-0" .032 191-0" 4,-0., 16-61. 4-0„ .024 W-10" 3'-0" T-8" 2'-6" .024 13,-2" 41-0" 10'-6" 3'-8" .042 17' (Y' 4'-0" 14.-3" 4'-0" 30 F.032 11'-10" ' 3'-10" 10,-10" 3'-5" .032 16-0" 4'-0" 12'-3" 4'-0" TRIBUTARY WIDTH TABLE CLEAR SPAN (FT.) PROJECTION O.H. 6 7 8 9. 10 11 12 13 14 15 16 17 18. 19 20 21 O.H. SPAN 0 3 4 4 5 5 6 6 .7 7 8 8 9 9 10 10 10 1' 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 11 2' 5 6 6 7 7 8 8 9 9 10 10 11 11 - 12 12 12 f1 3' — 7 7 8 8 9 9 10 10 11 11 12 12 13 13 13 TRIBUTARY TRIBUTARY= 4' — — — 9 9 10 10 11 11 12 12 13 13 14 14 14 WIDTH 1R SPAN+O.H. 5' — — — — — 11 11 12 12 13 13 14 14 15 15 15 • 6' — — — — — — — 13 13 14 14 15 15 16 16 16 7' — — — — — — — — — 15 15 16 16 17 17 17 NOTE: TRIBUTARY ON MULTIPLE SPANS IS EQUAL TO CENTER SPAN TO CENTER SPAN 8' — — — — — — — — — — — 17 17 18 18 18 — — 19 19 I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: SHEET REPORT NUMBER DATE: 11/23/2002 JAMES G.FOX. CNIL ENGINEER 10, 20830 psi DURALUM PRODUCTS, INC. ER -2640P SCALE:NONE 8060 TELEGRAPH RD., DOWNEV, CA 90240 RAFTER SPANS HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95626 60F 30 REVISED BY: K.K. 8 D.P. FAX:927.2509 (oxen hotmail.tpm 70, 90 8 110 MPH (562)80r,1337 g@ (916) 452-7021 FAX 4031519 sales@duratum.com HANGER CHANNELS AND MOUNTING BRACKETS ALUM. 3004-1-136 1'50 i o WALL " O1 FASTENERS 1.75 O ROLLFORMED HANGER R.F. OR EXT. HANGER CHANNEL, 2x OR 3x RAFTER BRACKET. ALUM.ALLOY 6063-T6 .060"111 y „ O EXTRUDED HANGER CHANNEL ALUM. PANEL 2x OR / l ' 3x ALUM. RAFTER R \ II 1 I FASCIA BOARD EXIST. EAVES, RAFTER ALLOWABLE PROJ. EXISTING EAVE . EXISTING EAVE CONNECTION WALL FASTENERS 2.740" SEE TABLE 2x61 /2" AT 2x FASCIA AT WOOD STUD LL=10 3' LL=30 DESIGN WISIMPSONA35 .25 V-6" CONCRETE #10 SMS @ PANEL 4'-5" A LL=30 LL=10 LL=20 LOCKS OR #8 SMS LL=10 LL=20 4"AT =.D6D" EA CONTACT C E H H STENERS K 205 CONTINUOUS A-RAIL ABLE tWA ROOF PANEL (WHERE OCCURS) ALUM.ALLOY K ROVED 3' D C y 6063-T6 ALUM.ALLw6063 OOF PANEL #10 SMS @ EA. CONTACT x T6 cr WALL CONNECTION O 3" HANGER I EXIST. RAFTER HANGER / RAIL FASTENER TO FASCIA, WALL ( STUD, MASONRY OR CONC.) ALLOWABLE DECK / RAFTER SPAN 2x61 /2" WIND AT 2x FASCIA AT WOOD STUD LL=10 AT MASONRY OR LL=30 DESIGN WISIMPSONA35 16"D.C. V-6" CONCRETE T -T' 4'-5" LL=10 LL=20 LL=30 LL=10 LL=20 LL=30 LL=10 LL=20 LL=30 70 A C C E H H J J K 90 B C C E H H J J K 110 D C C G H H J J K cr DESCRIPTION OF LAG SCREW (SEE NOTE BELOW) ZZ A=1/4"0x11/2"@12"O.C. E=3/8"0x21/2"@16"O.C. J=1/4"0x11/8"@16"A.B. F¢w B=3/8"0x11/2"@16"O.C. F=7/16"0x21/2"@16"D.C. K=1/4"0x11/8"@12"A.B. QNa : C=3/8"0x11/2"@12"O.C. G=7/16"0x21/2"@12"O.C. IL- D=7/16"0x11/2"@12"O.C. H=3/8"0x21/2"@12"D.C. EXIST. RAFTER '3/4" OR 1 1/2" ALLOWABLE DECK / RAFTER SPAN 2x61 /2" RAFTER SIZE SPACING OVERHANG LL=10 LL=20 LL=30 2"x4" FULL OR 2" x 4"1' " FULL OR 16" O.C. V-6" 14'-5" T -T' 4'-5" 2'4' 8'-5" 4'4" 2'-4" 24" O.C. 8'-2" 4'-3" 2'-5" 8 OR 2xe LEDGER. >X -- 2"x6"FULL OR 2"x8"NOTCHED 24" O.C. 2'-a' 17'-5" 9'-1" 5'-6" 2"x8" FULL 24" O.C. 2'-a' 23'-1" 22'-1" F -577J 1 10# L.L.=(2)#8 SMS EA. SIDE 20#/30#L.L.=(2)#10 SMS EA. SIDE ' 3/16„ NOTE: 10, 20 & 30 L.L.= V2-#14x2 oFEsslo2x6 DF -L #2 LEDGER MAY BE INSTALLED WHERE P17 Es G.p WD. SCREWS L.L.=20 NEEDED TO EXIST. WALL AT WD. STUDS (16"O.C.) NO. 21543USE: • 9-30620D7 s ES GN LOADS. SCREWS ALL (2)-3/8"0x5" LAGS 3" APART VERT. AT 16" O.C. S CIVIL THE INSTALLATION OF LAG SCREWS & WOOD SCREWS ARE REQUIRED TO BE IN ?Z OFCAUF RAFTER TO ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION (NDS), SECTIONS 9.1.2 & WALL CONNECTION O3 11.1.2. DSMST&B AT 12" O.C. 6„ O STEEL '3/4" OR 1 1/2" 1/4'0 HOLES,TYP. 2x61 /2" NOTE: PROVIDE WATER 5" IN. OR 8" PROTECTION, METAL FLASHING CAUCK JOINTS AND SLOPE I TO DRAIN RAFTER 1 1/4" ®4 /4" OR 1 1/2" NOTE: 10, 20 & 30 L.L.= V2-#14x2 oFEsslo2x6 DF -L #2 LEDGER MAY BE INSTALLED WHERE P17 Es G.p WD. SCREWS L.L.=20 NEEDED TO EXIST. WALL AT WD. STUDS (16"O.C.) NO. 21543USE: • 9-30620D7 s ES GN LOADS. SCREWS ALL (2)-3/8"0x5" LAGS 3" APART VERT. AT 16" O.C. S CIVIL THE INSTALLATION OF LAG SCREWS & WOOD SCREWS ARE REQUIRED TO BE IN ?Z OFCAUF RAFTER TO ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION (NDS), SECTIONS 9.1.2 & WALL CONNECTION O3 11.1.2. DSMST&B AT 12" O.C. 6„ O STEEL p p 1/4'0 HOLES,TYP. NOTE: PROVIDE WATER B' O OOr PROTECTION, METAL FLASHING CAUCK JOINTS AND SLOPE I TO DRAIN TYPICAL BRACKET 1 1/4" ®4 G.c. MAX. DIST. HANGER CHANNEL TO FIRST POST \ COVERSUPPORT ER -2640P BEAM OR WALL. EAVE LENGTH 12•-0' HORIZ. WIND= MAX. 7 OF 30 0 7OFJW 8 OR 2xe LEDGER. >X -- (562)80&1337 FAX:927.2509 -oxen (a-hotmail.mm ATTACHMENTS (}#10x VLE'R PATIOCOVER NOTE: PLACE'SIKA FLEX' OR SIMILAR DRAWN BY: K.K. MATERIAL BETWEEN BRACKET AND COMP. SHINGLE ROOFING TO PROVIDE SEAL NOTE:BRACKET MAY BE MOUNTED BRACKET CONNECTION 4/ BELOW RAFTER W/ HANGER CHANNEL SAME CONNECTION'S. I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11/232002 JAMES G.FOX, CNIL ENGINEER HANGER CHANNEL 10, 20 & 30 psi DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 ANDBRACKET HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 7 OF 30 0 7OFJW REVISED BY: K.K. 8 D.P. (562)80&1337 FAX:927.2509 -oxen (a-hotmail.mm ATTACHMENTS 70, 90 8 110 MPH FAX 403.1519 sales@dumlum.mm USE 2 EA. 6" APART MAX. 1.50"tL 1.50" .28" 3 .0 2' —T. COLUMN / POST 'TYPES & SURFACE MOUNT ATTACHMENT DETAILS 1 3„ 2„ I 3.00” SQ. 3;00"SQ. F_ .032" #10 SMS 3.00" SQ. ' — 024" @24"0 C. EA, SIDE 6.5" O 075" 032" I l 14"R 040" ALUbL ALUM. 1_ nay TYP. .048"STEEL .28" O 1 TWIN POSTJ- DRAWN BY: K.K. bU. ALUM. F'Ub I 1.5" SQ. ALUM. POST 'U' BRACKET @ 1 1/2' SO. POST ALUM. ALLOY 3004-1-136 ALUM. ALLOY 3004-1-136 W/4-#10 SMS OR I 1 12" SO. POSTS SHOWN USE @1.50" 1- 1/4'0 M.B. EA. ALUM. ALLOY 1POST. 11/2" BRACKET 1 2" 6063-T5 I I CENTER OF BOLT SQ. POST IS 9"LONG OR (2) AT 1 1/22"" I I I I / 111 .050" ED Id INSTALL WASH. PLATE 1-12' SO. x3/16' WHEN USING IN 110 MPH WIND AREA MATERIAL: 3004-1-136 ALUM. @ ROLLFORM 6063-T6 ALUM. @ EXTRUDED "U" BRACKET QpOFE SS110 ti µES G., z NO. 21543 m EXP. 9-30-2107 P S CNIL p ATE0 FCALFt11 5/8" PLASTIC PLUG 3" SQ. ALUM. POST WITH SIDE PLATES OD ALUM. ALLOY 3004-1-136 3.00"• OR 75" '5" 1.60" + 1.50 INSTALL WASH. PLATE ,070" TYP. 15/" x 5/16"x 5 W WHEN USING IN 110 MPH WIND AREA .070" BRACKET FOR 3" POSTS' ALUM "T" BRACKET 3" SQ. STEEL POST q 7/16"OHOLE ASTM A653 SS GRADE 40 STEEL 1ST TYP. USE FOR 3' OST ON 6'2-5/16"0 HC___ ALUM. ALLOY 6063-T6 =t. G =3"S .xt=.188" O H=3"SO.xt=.250" II J=4"SQ.xt=.188" cq K=5"SO.xt=.188" 3.0' 4.0' O:R:5: ;j SQUARE STEEL POST ASTM A653 SS GRADE 40 STEEL "T" BRACKET 2FLANGES 2 1 /8" APART BASEFLARES TO 3"WIDE EA. SIDE OF FLANGES Q1 -7/16"O HOLE & 2-3/8" HOLES TYP. EA. SIDE s DRAWN BY: K.K. FOX ENGINEERING INC. 2 1/8' 2 1/8" 'U' BRACKET @ 1 1/2' SO. POST 71 12• I - j'--'- MA• 7/8' W/4-#10 SMS OR I 1 12" SO. POSTS SHOWN F JAMES G. FOX, CIVIL ENGINEER 1- 1/4'0 M.B. EA. 10, 208 30 ps1 1POST. SHEET I 1 12' MIN. FROM 1 2" T BRACKET I I CENTER OF BOLT 7G @ 3'SO. POST W/ TO END OF POST (2}#10 SMS EA. 562 806-1337 FAX:927.25D9 foxenaSholmail.mm A. PL. (.18') SIDE OF POST OR (916) 452-7021 FAX 4031519 sales@dumfum.mm 11/16"0 ROD 3/16" 1/4' M.B. THROUGH 1/8' 2 1040 STL POST AUGER PARTS PAINTED "RUST-O-LEUM"OREQUAL 20" 1 12"TWIN POST: (1}1/4-,O M.B. Y0- PER POST (2 -TOT.) 212'x212" OR HOT DIPPED GALVANIZED x 7 GA. STL. 7 GA. STL. OR ELECTROPLATED BRACKET: IY1/4. 0ST (1 0 M.B. 4' DIA 9 GA. — R SI PER SIDE (2 -TOT.) ASTM A-36 HELIX 0- - 3l16" NOTE: 9'xt6'x7 GA. SINGLE PASS WELDED MAY BE USED WITH 6' STEEL PLATE ASTM A36 AUGER ANCHOR 1 1/2"SO. TWIN POST AUGER PARTS PAINTED OR 3"SO. ALUM. POST "RUST-O-LEUM" OR EQUAL NOTE: ONLY. OR HOT DIPPED GALVANIZED STEEL FOOTINGS AND AUGER ANCHOR TO BE OR ELECTROPLATED USED FOR 10 L.L. ATTACHED STRUCTURE ONLY. QCa Pnk- Cl AC —QT Q-1-1 TALI c cno COAlHNC SINGLE PASS WELDED STEEL FOOTING 6 C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. - LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 F JAMES G. FOX, CIVIL ENGINEER COLUMN/ 10, 208 30 ps1 DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE 6 8060 TELEGRAPH RD., DOWNEY. CA 90240 POST TYPES HORIZ. WIND = 8269 ALPINE AVE., SACRAMENTO, CA 95826 8 OF 30 I REVISED BY: K.K. 8 D.P. 562 806-1337 FAX:927.25D9 foxenaSholmail.mm 70,90 8 110 MPH (916) 452-7021 FAX 4031519 sales@dumfum.mm -OB H0' GFWt -" NOTES: ALL COMPONENTS ARE INTERCHANGABLE UNLESS OTHER WISE NOTED I.C.C. E.S. EVALUATION COLUMN / POST TYPES & SURFACE MOUNT AND EMBEDMENT DETAILS LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: ALUM.'T'BRACKET USE WITH REPORT NUMBER DATE: 11232002 JAMES G. FOX, CNIL ENGINEER CoLUMN/ 7 12" ' SHEET 11 POST TYPE B.C.D, OR E. SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 STEEL POST ONLY: HORIZ. WIND = MAX 12" MIN. FROM STEEL.TBRACKETUSE WITH (562) BOE -1337 FAX:927-2509 foxeng@hounail.com USE POST TYPE (3)-5/8"OBOLTS "o' oma' CENTER OF BOLT POST TYPE B,C,D,E,F,G,H,J OR K. F, G. H. J OR K _ FOR POST TYPE J I I TO END OF POST. 3" SG. POST ALUM.TBRACKET: i USE USE (2}1/4'0 x 3 3/4' HILTI 4- ' , (2}1/4'0 HILTI-KWIK'- KWIK BOLTS OR EQUAL 12 DEPTH OF 1 2 12"OBOLTS f } FOR ALL OTHER BOLTS, OR EQUAL, EACH SEE NOTES BELOW STEEL.'T'BRACKET: FOOTING OR 1 I 12' MIN. EMBD. j CONDITIONS 4 x.188" BRACKET TO SLAB. ('PER USE USE (2)-318'0 HILTI KWIK (2 1 1 ASTM A36 ICC E.R.4627, EMBEDED DOLOR EQUAL STEEL 2 12" MIN., 8 APPROVEDS T.O.C._ FOR 325# PULL OUT) '•• 0 'r0"SO.13ASE PtT. . 4 '•'/ l 12"SQ.BASEPLT 312' !., . M N. ' DE TH ; .4s.+.:: '. = 18"SQ.BASE PLT. 4 ••I••••• 3/16' TM A36 STEEIL r, x • SLAB SHALL BE IN v POURED CONCRETE "^ •: F in GOOD CONDITION FOOTING SEE NOTE • i ;•„ • •' , q ,+,; .;' a w 3' _ SQ. POST (STL.) —7 FORSIZE (12-12.0M.B. OR FLUTED SEE FOOTING z9 LONG, 1" SQUARE OR 4" SQ. POST (STL.) SCHEDULE QUAR FROM END SEE FIGS, INSERT OF POST SCHED. EXISTING SLAB 7 3" SQ. POSTS TO CONC. FOOTING $ SQUARE POST EMBED. 9 PL.1/2'THK. INTO FOOTING ' 1 12" 7• 1 12' 1 12• 9• 1 12" 2'1 1 14° 1 1 2" _WELDED STEEL BASE PLATE O ATTACHED ATTACHED ONLY NOTES: BASE PLATE SCHEDULE ALTERNATE FTG. FOOTING & ANCHOR BOLTS PLT. SIZE MAYBE USED WITH POST TYPE, SEE SHT. 1. DO NOT USE ALUM. 'T 10"SQ.xl/2" B. C. F. G BRACKET WITH 3X8 BM. WANSERT, MAG. BEAM, 4-,7- OR 10" I -BEAMS. 2. POST TYPE E WASHER PLATE, 2" X CUBE SIZE SO. 78' DEEP • CUBE FTG. FOOTING SIZE SINGLE POSTS EMBED. 12"SQ.xt/2" B. C, D, F, G, 8. H 18" 18" SQ 12" BOLTS 18"SQ.xl/2" B. C. D, F, G, 8 H 20" 21"SQ. 12" 23"& 24• CUBE (2}1/2.0 PULL-OUT= 625# MAX. EACH 3 12" 22" 25" SQ. l6,INSTALL 25" - 30' CUBE (4}12 PULL-OUT= 625a11 MAX. EACH 3 1/2" y BRACKET AT STEEL 'T 3. POST TYPE F DO NOT USE STEEL "T' BRACKET W/7" AND 10• I BEAMS. 4. POST TYPE G , 24" 28" SQ. 20" 26" 32" SO. 23" 31•-34•CUBE (4)-518.OPULL.OUT= 865# MAX. EACH 4" FREESTANDING BASE PLATE ANCHOR 28" 35" SO. 25" 35" - 39" CUBE (4}3/4'0 PULL-OUT= 13754 MAX. EACH 8• 30" 39" SQ, 28" BASE PLATE ANCHOR BOLTS (SIZE 8 TYPE 32" 43" SQ. 30" 40" - 42" CUBE (4)7"OPULL-OUT= 1835# MAX. EACH 6, 10"x10"x 12" (4)- 3/4"0 x 8" EMBEDMENT HILTI SS KWIK BOLT -II 34" 47" SO. 32" OO NOT USE STEEL?" BRACKETS W/ 10"I -BEAMS. PER I.C.C. E.S. #4627, PULL-OUT VALUE=1875# EA. NOTES: BOLTS SHALL BE HILTI SS KWIK BOLT -II OR EQUAL. NO SPECIAL INSPECTION REQUIRED PER I.C.C. EVALUATION SERVICE INC., ER #4627 36" 51"SQ. 38" 55" SQ. 3T' 12"xl2"x 12" (4)- 1"0 x 9" EMBEDMENT 40"60" 39" SQ. OF ESS IO 1 #MES G N9 C HILTI SS KWIK BOLT -II PER I.C.C. E.S. #4627, PULL-OUT VALUE=1995# EA 42" 64" SQ. 41" " 44 69" SQ. 43' Y NO. 21543 p EXP. 9a0 2007 'CUBE FOOTING W1312" SLAB 18"xt8"x 12" (4)- 1'0 x 6" EMBEDMENT * 4T1 cmc AP EOF HILTI SS KWIK BOLT -II PER I.C.C. E.S. #4627, - CAL 11'0P PULL-OUT VALUE= 3740# EA. NOTES: ALL COMPONENTS ARE INTERCHANGABLE UNLESS OTHER WISE NOTED I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CNIL ENGINEER CoLUMN/ 70, 208 30 pst DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 POST TYPES HORIZ. WIND = 8269 ALPINE AVE., SACRAMENTO, CA 95826 9 OF 30 REVISED BY: K.K. 8 D.P.70, (562) BOE -1337 FAX:927-2509 foxeng@hounail.com 90 8 110 MPHJOB (916)452-7021 FAX 4031519 sales@duralum.com "o' oma' HEADER BEAM TYPES & ATTACHMENT DETAILS 1.52 .61" GUTTER EXT. CLIP GUTTER EXT. CLIP 3.100" SQ. 2.00" SPLICE WHERE 1 • OCCURS SPLICE WHERE SPLICE WHERE 1.79" OCCURS OCCURS '- - 4.6" ,_ .. .075- 4.6' TYP. co 2.57" 14"R 2.19 2.04 TYP. 048„ oss 2.04• TYR 2.08" 065 • -- 3.0 . 4 _r _ TYP. , 93" 4.oaom 28" z.7ASTM A653 SS GRADE 40 .035" R.F. GUTTER - ALUM. ALLOY ALUM. ALLOY - FASCIA -ALUM. ALUM. ALLOY 6063-T6 6063-T6 ALLOY 3004-H36 A 6063-T6 O O D O 6.5" ROLLFORMED 4.5" GUTTER MAG. GUTTER MAG BEAM O 3" SQ. STEEL BEAM• 3.01- W-1 : 3,.2., ss' MAX: .. r-7 --I _T C . — .042" 7F_ SPLICE SPLICE NMERE WHERE 4" SPLICE WHERE OCCURS .0 4" 8.D" OCCURS 70„ - OCCURS 1 " TYP 140" Li-110" TYP. TYP. ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 ALUM.ALLOY ALUM. ALLOY 7J2 OR EQUAL 6063-T6 r 6063 -T6 \ ALUM. ALLOY OR EQUAL r ' 6063T6 (,^r 4" I -BEAM 7" I -BEAM 10" I -BEAM O DBL. 2.x 6.5 BEAM 3 x 8 BEAM O 3.0" 1.25" I ," ALTERNATE STEEL C -BEAM FOR ALUM. I -BEAMS __T 3" MAX. 3" 6 6 i 4" I -BEAM = 7"x 2 3/4"x 16 GA. STEEL C -BEAM — f— .042" .042" T=14 GA. 7"i -BEAM= 12"x 3 1/4' x 12 GA. STEEL C -BEAM 8" 7'$ 5 ASTM A653 GRADE 50 10" I -BEAM = W10 x15or S8 x 18.4 STEEL I -BEAM apfE5S10 ALUM. ALLOY 3004-H36 625" 1 9 ALUM. ALLOY 3004-H36 I1 NO. x w w OR EQUAL OR EQUAL O - 2.$75" 3 x 8 BEAM W/ STL. INSERT DBL. 3 x 8 BEAM 3 x 8 BEAM „E c'. STEELINSERT oFmL I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER 10.20 8 30 Dsf DURALUM PRODUCTS, INC. SHEET BEAM TYPES 10 OF 30 ER -2640P SCALE:NONE _ 8060 TELEGRAPH RD., DOWNEY, CA 90240 HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95626 REVISED BY: K.K. 8 D.P. 562 806.1337 FAX:927-2509 Pozen hohnail.mm 70, 90 8 110 MPH 1(916)452-7021 FAX 4031519 salesQdumtum.wm #10 S.M. (8 TOT.) SPLICE DETAILS (11 I BEAM TO POST DETAILS (2) SIMPLE SPLICE FULL MOMENT #12 S.M.S. (24 TOT. (2)#1 E M.TM(d. EA. ALUM. ALLOY 3004-H36 ' ALUM. ALLOY 3004-1-136 -BEAM DRAWN BY: K.K. FOX ENGINEERING INC. ,jyOFESSIO OR 6063-T5 FOR EXTRUDED OR 6063-T5 FOR EXTRUDED NE—_ - REPORT NUMBER NOTE: USE SIMPLE SPLICE ONLY NOTE: FULL MOMENT SPLICE MAY OCCL R O O O IN ALTERNATE INTERIOR BAYS AT ANY LOCATION EXCEPT AT END BAY SHEET 3..5" NOTCH I -BEAM FLANGE SPLICES - ROLLFORMED & EXTRUDED FASCIAS SPLICE DETAILS 1 I I AS NEEDED TO CLEAR #12 METAL BACKED, I -BEAM ALUM ALLOY 3.5" SO. POST,CONNECT WEB NOTE: IF SPLICE OCCURS AT ALTERNATE INTERIOR BAYS, A SINGLE 12" SIMPLE C -SPLICE (ONE SIDE OF WEB) MAY E E USED. (6061-T6) ALTERNATE I I TO POST W/(2}72"0 rX. FLANGE STL C THRU-BOLTS SPLICE WHER OCCUR! 4'TOTAL= (8)-12"0 BOLTS SO. POST 1. 5" o O O BEAM TO POST CONN. ALUM. ALLOY 6063-T6 1V- 7" 6" 7" I -BEAM -3'-0"- MOMENT C -SPLICE NOTE: IF SPLICE OCCURS AT ALTERNATE INTERIOR BAYS, A SINGLE 12" SIMPLE C -SPLICE (ONE SIDE OF WEB) MAY BIE USED SPLICE WHEF OCCUR ALUM.ALLOY 6063-T6 10" I -BEAM TOTAL= (12}12'0 BOLTS DRAWN BY: K.K. FOX ENGINEERING INC. ,jyOFESSIO LIVE LOAD= 4v P11,ESG,p Z 5 REPORT NUMBER DATE: 11232002p JAMES G. FOX, CIVIL ENGINEER O O O DURALUM PRODUCTS, INC. SHEET 3..5" SCALE:NONE $ 8060 TELEGRAPH RD., DOWNEY. CA 90240 SPLICE DETAILS 1 v j ---o 0 0 #12 METAL BACKED, 1)-e0FCALIF `P 3.5" 562 806.1337 FAX:927-2509 foxen t@hotmail.mm TEK SCREWS @ 8.0.C. 70, 90 8 110 MPH STAGGER IN BEAM O 0 rX. FLANGE 0 ROOF PANEL If (4}1/4'0 M.B. BEAM 7"x4' ALUM.'I' BM. TO BRACKET POST, SEE SCHEDULE — —V_ ALTERNATE BEAM TO POST CONN. 2'318'0 M.B. THRU STL - BRACKET TO POST. I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. ,jyOFESSIO LIVE LOAD= 4v P11,ESG,p Z REPORT NUMBER DATE: 11232002p JAMES G. FOX, CIVIL ENGINEER m NO. 21543 m 10, 208 30 psf DURALUM PRODUCTS, INC. SHEET EXP. 330-2007 P SCALE:NONE $ 8060 TELEGRAPH RD., DOWNEY. CA 90240 SPLICE DETAILS 1 HORIZ.WIND= 1 8269ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 #12 METAL BACKED, 1)-e0FCALIF `P NEOPRENE WASHERED 562 806.1337 FAX:927-2509 foxen t@hotmail.mm TEK SCREWS @ 8.0.C. 70, 90 8 110 MPH STAGGER IN BEAM "ao. 4P4 rX. FLANGE ROOF PANEL If (4}1/4'0 M.B. BEAM 7"x4' ALUM.'I' BM. TO BRACKET POST, SEE SCHEDULE — —V_ ALTERNATE BEAM TO POST CONN. 2'318'0 M.B. THRU STL - BRACKET TO POST. I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002p JAMES G. FOX, CIVIL ENGINEER 10, 208 30 psf DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE:NONE $ 8060 TELEGRAPH RD., DOWNEY. CA 90240 SPLICE DETAILS 1 HORIZ.WIND= 1 8269ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 11 OF 30 REVISED BY: K.K. D.P. 562 806.1337 FAX:927-2509 foxen t@hotmail.mm 70, 90 8 110 MPH FAX 4031519 sales@dumium.mm "ao. 4P4 BEAM TO POST CONNECTION DETAILS OPTIONAL DECORATIVE FASCIA BRACKET AT EACH (WOOD, ALUM. OR HARDBORD) - 112"SO POST ALUM 3.00' GUTTER FASCIA 3' SQ. POST OR 240" MAG BEAM 3" SQ. POST 3"SQ. STL. BEAM 14 GUTTER FASCIA MAG BEAM 3' SQ. POST 13 3"SQ. STL. BEAM p1 0FE sslo4, MEs G., 5 ' + yc Z w NO. 21543 m EXP. 9J0-2007 F - S CIVtL y T -0T6 ( C fOP ALUM. ALLOY 3004-H36 ` . 1.50" 28 r G I2.. I 2n 1 1 1/2" SQ. OR 2" LATTICE TUBE #8x2"SMS OR 2 1/2", TYP. RAFTER 1 1/2" SQ. LATTICE OR 2" @ WO.C. MIN. & 7"O.C. MAX. LATTICE TO RAFT. 1 O 1 1/2" .040" 3004-H36 ALUM. r - T • i , SCREWS NOTED IN DETAIL 1N TO BE @ CENTERLINE 1/2" MIN. EDGE DISTANCE, TYP. . FASTENER, -- PER DEATIL SEE VARIOUS DETAILS . W= 2 1/8" OR 1 1/8" FOR 6 1/2" RAFTER & W= 3 1/8" OR 2 7/8" FOR 8" RAFTER "U"BRACKET - GENERAL W -3I I.C.C. E.S. EVALUATION DRAWN BY: K.K. x.080' ALLOY 3004-H36 LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: (2}#10 S.M.S. EA. SIDE (4) -TOT. REPORT NUMBER " 2410x1/2'S.M.S.AT' 10, 20 & 30 Ps1 D.RALUM PRODUCTS, INC. SHEET ER -2640P • EACH POST _ HORIZ. WIND= 8269 ALPINE AVE.. SACRAMENTO, CA 95826 #10 S.M.S. TOP & BOTT. (2}TOT. 2412 x 1/2' S.M.S. EACH SIDE OF 3' ALTERNATE: - #10 x 1/2" S.M.S. TOP (916) 452-7021 FAX 4031519 salesQa duratum.mm F) SD. POST (4 -TOTAL) 1/4"0 BOLT AND WASHER & BOTT. (2) -TOT. 1 1/4' ALTERNATE: 114'0 BOLT WI WASHER EA. SIDE OF 3" SQ. POST ON CENTERLINE AT EACH POST. - 5 " ROOF PANEL 4' 61/ 1 PIANOFB CKEr •T 1II t 1.10" — — — — — — ROLLFORMED OR 75 1 1,() I EXTRUDED GUTTER ' 1.50' I FASCIA ALUM. BRACKET X L_+ #10 S.M.S. @12"O.C.. 3' SQ. POST 2.35' , — — — — — — 612"x2"x - - •.024"RAFTER ` 2410x1/2' S.M.S.` EACH SIDE OF 3" IRON TFACEOF - SO. POST (4 -TOTAL) AASCIA ALTERNATE: 114"0 BOLT W/ WASHER - - EA. SIDE OF3'SQ.POST LOCATION, OF 11/2'SO. POST RAFTER "TAIL" TO GUTTER L (2}02 S.M.S. ( 2 PER SUPPORT) / TO FASCIA. 3.00' GUTTER FASCIA 3' SQ. POST OR 240" MAG BEAM 3" SQ. POST 3"SQ. STL. BEAM 14 GUTTER FASCIA MAG BEAM 3' SQ. POST 13 3"SQ. STL. BEAM p1 0FE sslo4, MEs G., 5 ' + yc Z w NO. 21543 m EXP. 9J0-2007 F - S CIVtL y T -0T6 ( C fOP ALUM. ALLOY 3004-H36 ` . 1.50" 28 r G I2.. I 2n 1 1 1/2" SQ. OR 2" LATTICE TUBE #8x2"SMS OR 2 1/2", TYP. RAFTER 1 1/2" SQ. LATTICE OR 2" @ WO.C. MIN. & 7"O.C. MAX. LATTICE TO RAFT. 1 O 1 1/2" .040" 3004-H36 ALUM. r - T • i , SCREWS NOTED IN DETAIL 1N TO BE @ CENTERLINE 1/2" MIN. EDGE DISTANCE, TYP. . FASTENER, -- PER DEATIL SEE VARIOUS DETAILS . W= 2 1/8" OR 1 1/8" FOR 6 1/2" RAFTER & W= 3 1/8" OR 2 7/8" FOR 8" RAFTER "U"BRACKET - GENERAL W -3I I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11/232002 JAMES G. FOX, CIVIL ENGINEER 10, 20 & 30 Ps1 D.RALUM PRODUCTS, INC. SHEET ER -2640P SCALE:NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 BEAM TO POST HORIZ. WIND= 8269 ALPINE AVE.. SACRAMENTO, CA 95826 12 OF 30 REVISED BY: K.K. & D.P. 562 806-1337 FAX:927-2509 (oxen hotmail.wm 70, 90 8 110 MPH (916) 452-7021 FAX 4031519 salesQa duratum.mm Ae "o. crmas7. DOUBLE RAFTER CONNECTION DETAILS I LATTICE BEAM TO POST CONNECTION 1 1/2" OR 2"LATTICE #8 S.M.S. ALTERNATE 1/2" DOUBLE RAFTER - BOLT CONNECTION PLAN 2 ALTERNATE: 4-414 S.M.S. EACH RAFTER TO COL. CONNECT. (8 TOT.) 3"x 3"STL.POST (24") 1 17 1 ALTERNATE INSERT ATTACHED OR I (2)-2x6.5" OR 3"x 3"STL.POST COLUMN (2)-3"x8"HEADER FOR FREESTANDING _ (2}1/2"BOLT 2"x 6.5" SIDEPLATE DBL. RAFTER / DBL. HEADER CONN. 19 #8 S.M.S. EACH SIDE f— LATTICE 1 1/2" OR 2" 2"x6.5" OR 3"x8" RAFTER - ALTERNATE: 1/2" BOLT ALTERNATE: 2)- #10 S.M.S. EACH RAFTER TO COLUMN CONNECTION (4 -TOTAL) ALTERNATE: ALTERNATE: (2)- 2x6.5" OR (2)-3"x8" HEADER 3"x3"x0.024" (1) - 1/2" BOLT OR CONNECTOR (2)- #10 S.M.S. EACH RAFTER STUB COLUMN TO DOUBLE HEADER CONN. 20 /BEAM SPLICE TO ,-OCCUR DIRECTLY OVER POST. NOT PERMITTED @ 2 -POST UNITS i 5/8" 0 PLASTIC PLUG WHERE SCREW IS INSIDE 5" 5" #14 SMS MA) LIVE LOAD= BE USE AS 3.5" 3.5" ALTERNATE 7 JAMES G. FOX, CIVIL ENGINEER 1*(562)80G.1337 LATTICE 1/4"0 BOLTS t 3.5" 3.5" ER -2640P .5' IP_ 5' 8" BEAM E1 OR F2 8269 ALPINE AVE., SACRAMENTO, CA 95826 130E 30 6414 SMS EA. FAX:927-2SO9 (oxen hotmail.mm 9@ SIDE I I 6 1/2" SIDEPLATE EA #14 SMS EA. SIDE , I SIDE SEE POST SCH TOP, MID HEIGHT AND BOTTOM. 3"SQ. POST BETWEEN SIDE PLATES BEAM TO POST CONNECTION POST SCHEDULE 21 a3" SQ. x.024" + (2)-2" x 6 1/2" x.024" W/ (6)-#14 S.M.S. EACH SIDE. USE ON CONC. SLAB ONLY 3" SQ. x .024" + (2)-2" x 6 1/2" x .032" W/ (6)-#14 S.M.S. EACH SIDE. USE ON CONC. SLAB OR FOOTING. p1yOFESSloH ESG.p 9 i NO. 21543 m EXP. 9-30.2007 A 1} ST9T C AA a P EOFrgU0 I.C.C. E.S. EVALUATION EPORT NUMBER DRAWN BY; K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER 1*(562)80G.1337 LATTICE to,20. 30D= DURALUMPRODUCTS,INC. SHEET ER -2640P SCALE: NONE REVISED BY: K.K. B D.P. 8060 TELEGRAPH RD., DOWNEY, CA 90240 CONNECTIONS HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 130E 30 FAX:927-2SO9 (oxen hotmail.mm 9@ 70, 90 8 110 MPH (916) 452-7021 FAX 403-1519 sales nQduralum.mm Joe NO. GFC2 4 10# L.L. 70 / 90 -MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS �� FOX ENGINEERING INC. 6.5" ROLLFORM 4" I -BEAM 4.5" / MAG GUTTER MAG BEAM 3" SQ. STEEL BEAM z Fr 0z 10, 20 830 sl p 70 & 90 MPH SHEET 70 & 90 MPH SCALE: NONE 70 & 90 MPH 70190 FREESTANDING ANDATTACHED 70 & 90 MPH 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 70 & 90 MPH FREESTAND ATTACHED FREESTAND AT FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED p ? g MAX.POST MAX.POST MAX.POST MAX.POST MAX.POST 3 r a z SPACING SPACING SPACING SPACING SPACING FTG MIN. POST FTG MIN. POST FTG MIN POST FTG MIN. POST FTG MIN POST FTG MIN. POST FTG MIN POST FTG MM. POST Fl.G MIN POSTPOST FTG.MIN. p (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.] TYPE (IN.) TYPE 4' 17'-0" 14'-3" 277 F 22 A/B 21'-9" 270 G 22 Ay 15'-7 , 277 G 22 Ay 16'-4" 2 2 G 23 A� 13'-7" 276 F 22 % 5' 13'-7" 12'-9" 277 F 23 A� 19'-6" 270 G 22 p`� 14'-0" 26 F 23 AX 14'-7" 27 G 23 A>/ B 12'-2" 276 F 22 A� 6' 11'-4" 11'-7" 277 F 23 B 17'-9" 270 G 23 g 12'-9" 227 F 24 g 13'-4" 28 G 24 g 11'-1" ?76 F 1 23 1 g 7' 9'-8" 10'-9" 277 F 24 B 16'-5" 270 G 24 B 11'-9" 2�7 F 24 B 12'-4" 2�8 G 25 B 10'-3" 276 F 123 B 8' 8'-6" 10'-0" 274 F 24 B 15'-4" 277 G 24 g 11'-0" 274 F 25 B 11'-6" 274 G 25 B 9'-7" 22 F 1 24 B 9' T-7„ 9,-6„ 274 F 25 g 14'-6„ 277 G 25 g 10'-5, 274 F 26 g 10'-10" 274 G 26 g 9'-0" 22 F 124 B 10' 6'-9" 9'-0" 274 F 25 g 13'-9" 277 G 25 g 9'-10" 274 F 26 g 10'-3" 274 G 26 g 8'-7" 22 F 25 B 11' 6'-2" 8'-7" 274 F 26 B � 13'-1" 2�7 G 25 g 9'-s" 2�a F 26 B 9'-10" 2�4 G 27 g 8'-2" 21 F 25 B 12' 5'-8" 8'-2" 274 F 26 g 12'-7" 277 G 26 g 9'-0" 2�4 F 27 g 9'-5" 2�4 G 27 B T-10" 2�1 F 26 g 13' 5'-2" T-10" 271 F 26 g 12'-1 , 274 G 26 g 8'-8" 2%1 F 27 g 9'-0" 2%4 G 27 B T-6" 2%1 F 26 g 14' 4'-10" T-7„ 20721 F 27 B 11'-7" 2�4 G 26 g 8'-4" 2�1 F 27 B 8'-8" 2�1 G 28 B T-3" 20 F 26 B 15' 4'-6" T-4" 271 F 27 B 11'-3" 274 G 27 B 8'-0" 221 F 28 B 8'-1" 271 G 28 g T-0" 271 F 26 B 16' 4'-3" T -1n 2�/21 F 27 g 10'-10" 23 G 27 B 7'-9" 2�1 F 28 g 8'-1" 2�1 G 28 B 6'-9" �k1 F 27 B 17' 4'-0" 6'-10„ 2%1 F 27 g 10'-7„ 274 G 27 g 7'-7" 2�1 F 28 g 7'-11„ 2�1 G 29 g 6'-7„ 271 F 27 B 18' T-9" 6'-8" 179 F 28 g 10'-3„ 271 G 28 g 7'-4" 1j9 F 29 g . 7'-8„ 1%9 G 29 g 6,-4„ 1�9 F 27 g 19' T-7" 6'-6" %s F 28 g 10'-0" 271 G 28 g T-2„ /l9 F 29 g T-6" 119 G 29 g 6'-2" 1%9 F 27 B 20'3,-4„ 6'-4" 17s F 28 g 9'-8" 2, F 28 B T-0" 1%9 F 29 B T-3" %s G 29 B 6'-0" 1%9 F 28 B 21' „ 6'-2" 18 /s F 28 B 9'-6" 20 /1 F 28 B 6'-9" 18 /1s F 29 B T-1" 18 /1s G 30 B 5'-11" 1�9 F 28 g 3-2 NOTE: FOOTNOTE: "SAMPLE" QµOFESSIO� p� µE5 G. FOOTING SHOWN IN CUBIC INCHES + c WITHOUT SLAB. FIGURE INDICATES MAX.. HT. = 10'-0"m IGURE INDICATES MAX.. HT. = 12'-0" NO. 21543 SEE ALTERNATE FOOTING TABLES EXP. 9-3D-2007 n SHT. 9 FOR ATTACHED & srgrFOFI�par SHT. 29 FOR FREESTANDING I.C.C. E.S. EVALUATION DRAWN BY: K.K. �� FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE 10, 20 830 sl p DURALUM PRODUCTS. INC. SHEET ER -2640P SCALE: NONE E 8060 TELEGRAPH RD., DOWNEY, CA 90240 70190 FREESTANDING ANDATTACHED HORIL WIND = 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 14 OF 30 . REVISED BY: K.K. & D.P. 562 806-1337 FAX:927-2509 (oxen hotmail.com 70, 90 & 110 MPH FAX 403.1519 salm@dumlum.mm ,oe� 10# L.L. 70 / 90 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS 7" I -BEAM DBL. 2"x6.5"x.024"BEAM DBL032" BEAM o 3"x21 81iBEAM 3"x8" BEAMw/INSERT JO O m ¢ _ 70 MPH 90 MPH 70 8 90 MPH 70 & 90 MPH 70 8 90 MPH (916) 452.7021 FAX 4031519 salesQduralum.com 70 & 90 MPH FREESTAND FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHEDco rj o U z g MAX.POST MAX.POST MAX.POST MAX.POST F" ~ 3 a 9 z w 0 SPACING FTG. MIN. POST FTG.MIN. POST FTG MIN. SPACING I I FTGPOST MIN. POST FTG MIN. POST SPACING FTG MIN. POST FTG MIN. POST SPACING FTG MIN. POST FiG MIN POST 3 ~ (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE 4' 17'-0" 45'-3" 378 G 471 G 32 B 11'-7" 2 7 F 20 A/ 13' 10" 2 6 F 21 B 29'-3, 3 5 G 27 B 4' 5' 13'-7" 40'-6" 327 G 4 G 33 /E 10'_6" 227 F 21 B 12'-4" 226 F 22 B 26'-2" 25 G 28 B 5' 6' 11'-4" 37'-0" 337 G 140 G 34 2E 9-7 227 F 22 B 11' 3" 2 6 F 23 B 23'-11" 335 G 29 yC 6, 7' 9'-8" 34'-3" 35 G 471 G 35 E 8'-10" 2 27 F 22 B 10'-5" 2 26 F 23 B 22'-1" 335 G 30 C 7' 8' 8'-6" 32'-0„ 3 4 G 3 8 G 35 8'-4,. 274 F 23 B 9' 9 , 2 2 F 24 B 20'-8" 3 3 G 31 E 8, 9' 7'-7" 30'-2" 3 G %38 G 36 7'-10" 23 F 23 B 9'-5" 21 F 25 B 19'-6" 332 G 31 E 9, 10' 6'-9" 28'-8„ 3/34 G 3X8 G 37 7'-5„ 224 F 24 B 8' 9" 222 F 25 B 18'-6„ 323 G 32 10' , 6'-2" 27'-4„ 32 32 G 36 38 G 37 F 7'-1„ 2 4 F 24 B 8, „ 2 2 F 25 B 17'-8" 32 3 G 32 E 11' 12' 6-8" 26'-2„ 31 32 G 36 38 G 38 E 6, 9„ 23 24 F 24 B 8,_0„ 21 22 F 26 B 16'-11„ 32 23 G 33 B E 12' 13' 5'-2" 25'-1" 3X G 34/ G 38 F 6'-6" 2 F 25 B 7'-8" 2 F 26 B 16'-3" 2 G 33 E 13' 32 6 21 21 30 14' 4'-10" 24'-2" 332 G %6 G 39 F 6'-3" 2 F 25 B 7' a" 2 F 26 B 15'-8" 220 G34 E 14' 15' 4'-6" 23' 4" 31 32 G 34 2s G 39 E /F 6'-0" 20 2 F 25 B 7'-0" 20 2 F 27 B 15'-2" 29 9 G 34 15' 16' 4'-3" 22'-7" 322 G 376 G 40 F 5'-9" 22 F 26 B 6'-8" 22 F 27 B 14'-8" 29 G 34 E 16' 17' 4'-0" 22'-0„ 30 G 34 3s G 40 F 5. 6„ 20 2 F 26 B 6, 4., 20 2 F 27 B 14'-3„ 29 20 G 35 B 17' 18' 3'-9" 21'-4" 3 0 G 33/ G 41 F 5'_3" 1%9 F 26 B 6'-0" 1 19 F 28 B 13'-10" 2 27 G 35 E 18' 19' 3'-7" 20'-9„ 320 G 3314 G 41 F 5'-0„ 1N9 F 27 B 5'-8„ 1 9 F 28 B 13'-5„ 26/7 G 35 E 19' 20' 3'-4 , 20'-3" 3/330 G 3/324 G 41 F 4'-9" 18 /9 F 27 B 5'-4" 1 g 19 F 28 B 13'-1 " 2/62 27 G 36 B /E 20' 21' 3'-2" 19'-9" 270 G 333 G 42 F 4'-6" 1A9 F 27 B 5'-0" 1 9 F 28 B 12'-9" 2 26 G 36 XE 21' NOTE: FOOTNOTE: "SAMPLE" '? OFESSIO4 FOOTING SHOWN IN CUBIC INCHES 'Pkes c,c+ tic WITHOUT SLAB. FIGURE INDICATES MAX.. HT. = 10'-0"2 FIGURE INDICATES MAX.. HT. = 12'-0" m NO. 21543 SEE ALTERNATE FOOTING TABLES EXP 9-30-2007 p SHT. 9 FOR ATTACHED & t SHT. 29 FOR FREESTANDING cNO. Nr OFCq 1F I.C.C. E.S. EVALUATION REPORT NUMBER DRAWN BY: K.K. DATE: 1 1/2312002 FOX ENGINEERING INC. P JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE LIVE LOAD= 10, 20 8 30 psf PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE:NONE REVISED BY: K.K. 8 D.P. $ 8060 TELEGRAPH RD., DOWNEY, CA 90240 562 806-1337 FAX:927.2509 foxen (alhotmail.mm 70190 FREESTANDING ANDATTACHED HORIZ. WIND= 70,90 8269 ALPINE AVE., SACRAMENTO, CA 95826 15 OF 30 8 110 MPH (916) 452.7021 FAX 4031519 salesQduralum.com 10# L.L. 110 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS _L FOX ENGINEERING INC. 6.5" ROLLFORM 4" I -BEAM 4.5 / MAG GUTTER MAG BEAM. 3" SQ. STEEL BEAM = Is p J CD 00 MAX.POST 110 MPH MAX.POST X. 110 MPH MAX.POST 110 MPH MAX.POST 110 MPH MAX.POST 110 MPH FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED azg X z p SPACING SPACING SPACING SPACING SPACING FTG. MIN. POST FTG MIN. POST FTG MIN. POST FTG ' MIN. POST FTG MIN. POST FTG MIN. POST FTG MIN. POST FTG MIN. POST FTG MIN. POST FTG MIN. POST (IN.) TYPE (IN.) TYPE (IN•) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE 4' 17'-0" 11'-7" '/"3/2 F 23 % 18'74,, 3%6 H 27 A 12'-9'. 3 3 F 24 A 13'-4" 3%a F 25 A 11'-11I 31 / /32 F 23 A B 5' 13'-7"PT-0 ' 3X2 F 24 A 16'-5" 3 6 G 28 A B 11'-5" 373 F 25 Y 11'-11" 37 F 26 A 9'-11" 3 2 F 23 AX 6' 11'-4„/2 F 23 A B 15'-0" 3 6 G 29 B 10'-5" 3 3 F 26 A 10'-10„ 3 4 F 26 A 9' 0" 3 2 F 25 AX 7' 9'-8" 3X2 F 26 AY 13'-10" 3 6 G 30 B 9'-7" 3X3 F 26 A 10'-0„ 3X34 F 27 AYB 8'-4" 3X2 F 25 AX 8' 8'-6" //9 F . 26 A B 13'-0„ 373 G 31 B 9'-0„ 2;0 F 27 B 9'-5, 30 F 28 A31 7'-10" 2 9 F 26 A 9' 7'-7" /29 F 27 A 12'-3,, 32/3 G 31 B 8'-6,. 270 F 28 A 8'-10" 371 F 28 B 7'-4„ 2 9 F 26 A 10' 6'-9" Y9 F 27 A B 11'-7" 37333 G 32 B 8'-0" 270 F 28 A/ 8, 8„ 30 F 29 A 7'-0" 2 9 F 27 AX 11' 6'-2" //9 F 28 Ax 11'-1„ 3 3 G 32 B 7'-8„ 2 0 F 29 A/ 8'-5, 3 1 F 30 A/ 6'-8" 2 9 F 27 A/ 12' 5'-8" 6'-8" /29 F 28 B 10'-7" 3 `3 /i3s G 33 B T-4" 2/30 F 29 A 7'-8" 30 1 F 30 A 6, n 2 9 F 28 A /B . 13' 5'-2" 6'-5" 6 F 29 A/ 10'-2" 2/30 G 33 B 7'-0" 2 7 F 29 A 7'-4" 2 a F 29 6'-1" 2 6 F 28 A/ 14' 4'-10" 6'-2" 6 F 29 A 9'-10" 2 0 G 34 B 6'-9" 277 F 30 A 6'-10" 2 8 F 30 Ay 5'-10" 2 6 F 28 AX 15' 4'-6„ 6'-0" 2 6 F 29 g 9'-6" 2 0 G 34 B 6'-7" 2 /7 F 30 A/ 6'-10" 2 8 F 30 A/ 5'-7" 226 F 29 A/ 16' 4'-3" 5'-9" 6 F 29 A 9 -2 2 0 G 34 B 6'-4" 2/27 F 31 B 6'-7" 2%8 F 31 A 5,-4„ 2Y6 F 29 A/B 17' 4'-0, 5'-9" %6. F 30 g 8'-11„ 2 o G 34 B 6'-2„ 2 7 F 31 A 6'_5„ 2 8 F 31 B 5'-1„ 2Y6 F 29 A/ B 18' 3'-9" 5,_5„ %/4 F 30 % 8'-8„ 2/7 G 35 B 6'-0„ 2 4 F 31 A% 6,_3„ 2 5 F 31 4'-10" 2k24 F 29 AXB 19' 3'-7" 5'-4" 2 4 F 30 A 8,_5n 2%7 G 35 B 5'-10„ 2 4 F 31 A 6,_1„ 2 5 F 32 A 4'-7„ 2 4 F . 29 A 20' 3,-4„ 5'-2" 4 F 31 A/ 8'-2" 2/Z7 G 35 B 5'-8" 2/Za F 31 A/ 5'-11" 275 F 32 : A B 4' 4" 2Y4 F 29 A/ 21' 3'-2" 5'-0" 4 F 31 A B 8'-0" 26/7 /2 G 36 B 5'-6„ 23/4 2 F 32 A/ 5-9 2 5 F 32— A 4,_1„ 2Y4 F 29 A,B NOTE: eFEssbro FOOTING SHOWN IN CUBIC INCHES FOOTNOTE: "SAMPLE" PMEs c,F + c WITHOUT SLAB. FIGURE INDICATES MAX.. HT. = 10'-0"m FIGURE INDICATES MAX.. HT. = 12'-0" NO. 21543 SEE ALTERNATE FOOTING TABLES EXP. 9_30.2oo7 n SHT. 9 FOR ATTACHED & 't SHT. 29 FOR FREESTANDING srq cl L xr OF IFP I.C.C. E.S. EVALUATION DRAWN BY: K.K. _L FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 i JAMES G. FOX, CIVIL ENGINEER POST SPACINGTABLE 10, 20830 psf DURALUM PRODUCTS, INC. $HEFT ER -2640P SCALE: NONE $ 8060 TELEGRAPH RD., DOWNEY. CA 90240 110 FREESTANDING HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 16 OF 30 REVISED BY: K.K. & D.P. 562 806-1337 FAX:927-2509 (oxen hotmaiLmm ANDATTACHED 70, 90 & 110 MPH (916) 452.7021 FAX 403.1519 saIlm@dumlum.mm 10# L.L. 110 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS FOX ENGINEERING INC. LIVE LOAD= 7" I -BEAM 10" I -BEAM DBL. 2"x6.5N.024"BM DBL032" BEAM 0R 3"xs''BEAM 3"x8" BEAMMINSERT Q= j p J Lo) ? g MAX.POST 110 MPH MAX.POST 110 MPH MAX.POST 110 MPH MAX.POST 110 MPH MAX.POST 110 MPH FREESTAND (562) 8061337 FAX:927-2509 loxeng@holmail.mm ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED 3 F- a Z SPACING SPACING SPACING SPACING SPACING FTG MIN. POST FTG MIN. POST FTG. MIN. POST FTG MIN. POST FTG. MIN. POST FTG MIN. POST FTG. MIN. POST FTG MIN. POST FTG MIN. POST FTG MIN. POST p (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE 01'- TYPE (IN.) TYPE (IN.) TYPE (IN.) TYPE 4' 17'-0" 37'-0" 4 34 B 52'-2" 5 3 K 38 F 9'-7" %2 F 22 B 11'-3" X32 F 23 B 23'-11" "a" ao G 30 g 5' 13'-7" 33'-1" 74 J 36 B 46'-8" 5'3 K 40 F 8'-7" 72 F 23 B 10'-1" 332 F 24 B 21'-4" 3 40 G 31 B 6' 11'-4" 30'-2" 4 j 37 B 42'-7" 503 K 41 F 7'-10" 72 F 24 B 9'-2" %2 F 25 B 19'-6" 0 G 32 B 7' 9'-8" 27'-10" 74 H 38 E 39'-3" 50 K 42 F 7'-2" 72 F 24 B 8'-6' 3%2 F 26 B 18'-0" 0 G 33 B 8' 8'-6" 26'-1" 42 4 XO 37 E 36'-11" 4 9 K 43 F 6'-9" B F 25 B 8'-0" 2 9 F 26 B 16'-11" /37 G 33 B 9' 1 7'-7" 24'-8" 2 H 39 E 34'-10" a 9 44 F 6'-4" 78 F 25 B 7'-6" 279 F 27 B 15'-11" 7 G 34 B 10' 6'-9" 23'-4" 72 G 40 E 33'-0" 479 j 45 F 6'-1" 78 F 26 B 7'-1" 279 F 27 B 15'-1' _ /37 G 35 B 11' 6'-2" 22'-3„ 40 2 G 41 E 31'-6„ 48 749 j 45 E 5'-9„ 27 8 F 26 B 6'-9" 28 9 F 27 B 14'-5" 3 /37 G 35 B 12' 5'-8" 21'-4" 2 G41 F30--1 49 46 F 5'-7" B F 26 B 6"6„ 279 F 28 B 13'-7" /37 G 35 B 13' S'-2" 20'-6" 7o G 42 F 28'-11" a44 3 47 F 5'-5" 5 F 27 B 6'-3" 25 F 28 B 13'-3" 734 G 36 B 14' 4'-10" 19'-9" 4o G 42 F 27'-11„ x745 3 47 F 5'-3" 75 F 27 B 6,_0„ 276 F 29 B 12'-9" 3 34 G 37 B 15' 4'-6" 19'-1" 7o G 43 26'-11" 4 5 j 48 F 5'-1" 5 F 28 B 5'-10„ 25726 F 29 B 12'-4" /s4 G 37 E 16' 4'-3„ 18'-6" 7o G 43 F 26'-1" 4 5 48 F 5'-0" 5 F 28 B 5'-7 225 F 29 B 11'-11" /s4 G 37 E 17' 4'-0, 17'-11" 8 G 44 F 25'-4" a 5 j 49 F - - - - 5'-4" 2 6 F 29 B 11'-7" 734 G 38 E 18' 3'-9" 17'-5" 78 G 44 F 24'-7„ 42-, 43 j 49 F - - - - - 5'-1„ 2 4 F 29 B 11'-3" G 38 E 19' 3'-7, 16'-11" 78 G 44 VF23'-11" 3 3 50 F - - - - 5'-0„ 24 F 30 B 10'-11 /31 G 38 20' 3 „ 16'-6" s G 45 F 23'-4" a 43 50 F - - - - - - - - - - 10'-8„ 3 31 G 39 E 21' 3'-2" 16'-1 " 78 G 45 F 22'-9" 4 / 43 50 F - - - - - - - - - - 10'-5" /31 G 39 E NOTE: 9aQFESS,04,,, FOOTING SHOWN IN CUBIC INCHES FOOTNOTE: "SAMPLE" Q4'P"ES G. WITHOUT SLAB. FIGURE INDICATES MAX.. HT. = 10'-0 Z FIGURE INDICATES MAX.. HT. = 12'A" NO. 21543 a W. aao-soo7 SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & 6 CIVIL p SHT. 29 FOR FREESTANDING greeFcn FdN' I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: SHEET REPO REPORT NUMBER DATE:1123/1002 JAMES G. FOX, CIVIL ENGINEER POST SPAMNGTABLE 10, 20830 Psf DURALUM PRODUCTS, INC. 17 OF 30 vOW. 0P SCALE: NONE Y 8060 TELEGRAPH RD.,DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED 1 HORIZ. WIND= 1 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 oroias,- REVISED BY: K.K. & D.P. (562) 8061337 FAX:927-2509 loxeng@holmail.mm 70.90 6 110 MPH FAX 403.1519 sales@duralum.mm 20# L.L. 110 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS FOX ENGINEERING INC. 6.5" ROLLFORM 4" I -BEAM 4.5 / MAG GUTTER MAG BEAM 3" SQ. STEEL BEAM = - 3 J co O z 5 r, — co O MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FTG. (IN.) MIN. POST TYPE FTG. (IN.) MIN. POST TYPE FTG. (IN. MIN. POST TYPE TYPE FTG CIN.) MIN. POST TYPE FTG. (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG. (IN.). MIN. POST TYPE FTG (IN.)' MIN. POST TYPE FTG. (IN.) MIN. POST TYPE FTG ' (IN.) N. POST TYPE a' 8'-11" 10'-3" 30 31 F zs B 15'-11" / j 2s B 11'-3" 31 Cj 23 g 11'-9" 3 G 2a B 9'-9" (', 71 g s 7'-1" 9'-2" F 23 B 14'-3" G z7 B 1 o'-1" 3% G za B 10'-6" 3% G 2a B s' 9" 2 G 23 B s 5'-11" 8'-5" 30 31 F 24 B 13'-0" 33, G z8 B 9'-2" 3 G zs B 9'-7" 3/ G zs B 8'-0" % G za B T 5'-1" 7'-9" z7 z8 F zs B 12'-0" %, G 29 B 8'-6" G 26 B 8'-11" 31 32 G 26 B 7'-5" G za B Ir 4'-5" 7'4" %2 F 25 B 11'-3" 30/ G 29 B 8._0n % G zs B 64" G 2s B 6'-11" % F 2s B 9 3'-11" 6-10" 2/ F 26 B 10'-7" 30/ G 30 B 7._6n 2% F 27 B 7'-10" 2Y F 27 B 6.6.. % F 25 B 10, 3'-6" 6-6" z7 26 F 26 B 10'-1" %, G 30 B 7'-1" F 27 B 7'-5" 28 29 F 27 B 6-2" % F 26 B 11•3'-2" 6._2.. z7/ F 27 B 9'-7" 30 31 G 31 B 6'-9" 2 9 F 27 B 7'-1.. z , F 28 B 5'-11" %. F 26 B 17 - 5'-10,. 27/ F 27 B 9,_2.. 30/ G 31 B 6'-6" 2X F 28 B 6'-9" za/ F 28 X 6-8" F 27 B 13 - 5'-6" 778 F 27 B 8'-10" 30 31 G 32 B 6'-3" 6 F 28 B 6'-6" F 29 6-5"24 2s F 27 B 14, _ 5,_2., z7 z8 F 27 B 8'-6" z G 32 B 6-0" zs zs F zs B 6._2" n/ F 29 B ,/E 5-2" 2/ F 1 27 B 15, - - - - - - 8'-2" T7/ G 32 B 5'-10" z/ F 29 B 6'-1" % F zs / - - - - 16' - - - - - - 7'-11" /. G 33 B 5'-8" % F 29 B 5'-10'. 2Y F 29 /E 17• _ - - - - - 7'_8" 2728 G 33 B 6-6" % F 30 B 5-8" z3 24 F I 30 / - - - - - NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & SHT. 29 FOR FREESTANDING FOOTNOTE: "SAMPLE" FIGURE INDICATES MAX.. HT. = 10'-0" IGURE INDICATES MAX.. HT. = 12•-0" ,?,OF E SSlpy >P' •ES G.p t Z NO. 21543 in EXP. 930.2007 z SA CP/R y 9)F CFCPLFO I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: EE SHEET REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER POST SPACINGTABLE 10, 208 30 psf DURALUM PRODUCTS, INC. ER -2640P SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 110 FREESTANDING I HORIZ. WIND= I 8269 ALPINE AVE., SACRAMENTO, CA 95826 18 30 REVISED BY: K.K. 8 D.P. 562 806-1337 FAX:927.2509 foxen9@hotmail.mm ANDATTACHED 70, 90 8 110 MPH (916) 452.7021 FAX 403-1519 salw@dumfum.mm 20# L.L. 110 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS FOX ENGINEERING INC. LIVE LOAD = 7" I -BEAM 10" I -BEAM DBL. 2"x6.5"x.024"BM DBLBEAM oR 3"x8''8 AM 3"x8" BEAMMINSERT = F 5 p I— J t9 m O O i g a Z p MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH FREESTAND ATTACHED ESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FTG (IN.) MIN POST TYPE FTG (IN.) MIN. POST TYPE FTG ) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN POST TYPE FTG (IN.) MIN POST TYPE FTG (IN•) MIN. POST TYPE FTG (IN-) MIN. POST TYPE 4' 8'-11" 32'-9" Y4, G 33 F 46'-2" K 37 F 8'-6" G 2, B 10'-0" 7 G 22 B 21'-2" G E s T_1 . 29'-4" az / G 3a F 41'-s" as / K 3e F T-7" / G zz B 8'-11" zs / G z3 B 18'-11" G 3o C E e 5'-11" 26'-9" aY G 35 F 37'-9" % K 39 F 6'-11" G z3 B 8'-2" 29 G za B 17'-3" G 31 c r 5'_1n 24'-9° a/ G 36 F 35'-0" % K 4o F 6'-5" % F z3 B T-7" % G zs B 16'-0" % G 3, E s 4'_5" 23'-2" % G 37 F 32'-8" K 41 F 6-0" % F za B 7'-1" % G 21 B 15'-0" % G 32 E 9 3'-11" 21'-10" % G 38 F 30'-10" a% J 42 F 5'-8" z% F 24 B 6-8" 2/7 G 26 B 14'-1" G E IV 3 _g 20'-8" G 38 F 29'-3" %J 43 F 5'-4" 26 F 25 B 64" Y27 F zs B 13'-5" G 33 E 3-2" 19'-9 G 39F 27'-11" %J as F j XF B 6 26 727 F B G 34 F 17 - 18'-11" G 4o F 26'-8" °% J 4a F jG 4'-11" X F 25 B 5'-9" Y F 27 B 12'-3" Y G 34 F 13' - 18'-2" 40 G 4o F 25'-8" % 47 J 45 F /G - - _ - - 5'-6" 24 F z7 B 11'-9" 31 G 3s E E 14' - 17'-6" G a, F 24'-9" j45 FX - - - - - 5 -4 24 F 27 B 11 -4"Y G 35 F 15' - 16'-11" Y G 41 F 23'-10" % J F - - - - - 5'-2" % F 28 B 10'-11" Y G35 E F to - 164" Y G 41 F 23'-1" % J 46 F _ - _ - - - - - - 10'-7" G E 1r - 15'-10" % G 42 F 22'-5" % J 47 G - - _ - - - - - - - 10'-3" X G E NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & SHT. 29 FOR FREESTANDING FOOTNOTE: "SAMPLE" FIGURE INDICATES MAX.. HT. = 10'-0"—E+ FIGURE INDICATES MAX.. HT. = 17-0„ ,? OFESSl0 K.ES G., ZC i NO. 21543 m EXP. 9JP2007 xt Sp CIVIL p n oFCALFO( I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD = PATIO COVER SYSTEM AS MFG. BY: SHEET REPORT NUMBER DATE: 11232002 10JAMESG. FOX, CIVIL ENGINEER POST SPACING TABLE 10,208 30DURALUM 1 PRODUCTS, INC.SCALE: 1(916)452-7021 19 OF 30 ER -2640P NONE 8060 TELEGRAPH RD.,DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED 1 HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 roe s REVISED BY: K.K. 8 D.P. 562) 806-1337 FAX:927-2509 foxeng0hotma8.mm 70.90 9 110 MPH FAX 403-1519 sales@duralum.mm 30# L.L. 110 MPH FREESTANDING & ATTACHED SOLID PATIOS 12' OR LESS FOX ENGINEERING INC. 6.5" ROLLFORM 4" I -BEAM 4.5 / MAG GUTTER MAG BEAM 3" SQ. STEEL BEAM Q= ca 3 J110 O z00 a O MAX.POST SPACING MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH FREESTAND I ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FTG (IN.) MIN. POST TYPE FTG. (IN.) MIN- POST TYPE . FTG. (IN. MIN. POST TYPE FTG (IN-) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG .(IN.) MIN. POST TYPE FTG (IN-) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG. (IN.) MIN. POST TYPE FTG "(IN.) MIN. POST TYPE 4' 6-0" 8'-5" G z, C - %G za C /. G zzC% -8 G z E '-" j G 21 B s 4'-10" T-7" % G zz C 11'-9" 3 2 G 25 C 8'-3" G 23 C 8'-8" Y G z3 E T-2" G zz B s 4'-0" 6'-11" /0 F 23 10'-9" 3Y G zs C T-7" % F 24 C T-11" Y G 24 E 6'-7" Y F zz B r T-5" 6'-5" F 23 C 9'-11" 3Y G 27 C T-10" % F 2s C 7'-4" % F 25 E 6'-1" F z3 B Ir T-0" 6'-0" % F 24 C 9'-3'. 2Y G 27 C 6'-7" zs 27 F ' C 6'-10" % F 2s E 5'-8" % F 23 B s 2'-8" 5'-7" F 24 E s'-9" G za B 6'-2" Y F is C 6'-5' % F zs E 5'-4" X F 24 B 10 2'-5" 5'4" F zs C 8'4" z G za E 5'-;l 0" z% F 25 C 6'-1" F zs E 5'-1' F 24 B 11' - 5'-1.. z F zs 7'-11"% G zs B 5'-7" %z7 F C 5'-10" F E 4'-10" F B ,z - 4'-10" % F 25 E T-7" G 5' 4" F C 5'-7" % F E 4'-7" % F 25 B 13' - - - - - - 7'-3"Y G 3D BX 5'-1" Y F 2s C 5' 4" 2% F z7 _ - - - - 14' - - - - - - T-0" zY G 30 /E 4'-10" 1 % F 27 1 C 5'-2" % F n E - - - - - NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & SHT. 29 FOR FREESTANDING FOOTNOTE: "SAMPLE" FIGURE INDICATES MAX.. HT. = 10'-0" FIGURE INDICATES MAX.. HT. = 12.-O" - p ppOFESSIph vl pM FS G. F 5 + c z NO. 21543 m EXP. 330-2007 z C Ny gTFOFCp1.1F0aa P I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. REPORT NUMBER DATE: 11/23/2002 JAMES G. FOX, CIVIL ENGINEER POSTSPACINGTABLE 10, 20830 psf DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE ' 8060 TELEGRAPH RO., DOWNEY, CA 90240 110 FREESTANDING I HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, Q11:1. 2, OF30 REVISED BY: K.K. 8 D.P. (562) 806-1337 FAX:927-2509 foxeng@h"tmafl.mm ANDATTACHED 70, 90 8 110 MPH— (916) 452-1021 FAX 403.1519 sales@duraNm.mm W. w0 —. >_7" DRAWN BY: K.K. I -BEAM 1011 I -BEAM DBL. 2"x6.5"x.024"BM Ut5L•Z A 3'xs'U63EAMCHIVI 3"x8" BEAMw/INSERT S p 00 z g n z m w O MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH MAX.POST SPACING 110 MPH FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FREESTAND ATTACHED FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POSTPOST TYPE FTG.MIN. (IN.) TYPE FTG (IN.) MIN. POST TYPE FTG (IN•) MIN. POST TYPE FTG (IN.) MIK POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE FTG (IN.) MIN. POST TYPE 4' 6-0" 27'-0" J 31 E�/F 38'-1" a/a H 35 F T-0" z� F 20 g 8'-3" 299 G z1 B 17'-5" a� G 27 g s 4'-10" 24'-1" 40 41 .� az E� 34'-1" H 36 F s' -3"z/29 F 1 21 B 7'-4" 29G zz B 15'-7" a� G ze B 9 4'-0" 22' -on 40/ H 33 F 31'-1 „ aa/ H a7 F 5' 8" 2Y F 21 B 6'-8.. zs/ r + 22 g 14'-3° a% G 29 E r 3'-5" 20'-4" 40 41 G 34 F 28'-9" X H 38 �G 5'-3" 28/ F 22 B 6'-2" �% G 23 B 13'-2" 3Y G 29 E/ a 3'-0" 19'-1" 37 G 35 F 26'-11" a1 H 3s V_ G - - _ - _ 5'-10" 27 G 2a B 12' 4" 3a / G 3o E g 2'-8" 18'-0.. 3X G 35 F 25'-4.. aX H 40 F/G - - _ - _ 5'-16"27 G za g 11'-7" G 31 E� 1a 2'-5" 17'-0.. 37/ G ss F 24'-1 aX H VG _ _ 5'-2" 26/ G to B 11'-0,. 344 G 31 E� 11' 16-3 3 X38 F22-11XazH a a1 G 4-11.6/Gg10-6 z X G�/F az E_ 17 - 15'-7,. 3X G 37 F/G 22'-0" 41 H 42 G - - _ - _ 4'-9.. zs/ G g 10'-1,. 3a/ G E/ 13 - 14'-11 38 F /G X H G _ a1% 32 G 33 E 1a' - 14'-5" 344 35 G 38 F/ G 20-4 X H 43 G - - - g'-4" 31 32 G 33 F 1s - 13'-11.. 34/ G 38 G/G 1g'-8„ 38/ H 43 G 3% G 33 F NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED 8 FOOTNOTE: "SAMPLE" SHT. 29 FOR FREESTANDING FIGURE INDICATES MAX.. HT. = 10'-0"-14 FIGURE INDICATES MAX.. HT. = 12'-0" QROFE SSIO,y i. >P'MES G.a + yC 4 NO. 21543 m EXP. 93(Q007 P 4 CIyO. p FCAU I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11!23/2002 JAMES G. FOX, CIVIL ENGINEER 1010, POST SPACING TABLE 20 a 30 pst DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED HORIZ. WIND= 8269ALPINE AVE., SACRAMENTO, CA95826 21 OF 30 REVISED BY: K.K. a D.P. 562 806.1337 FAX:927-2509 (oxen hotmail.mm 70, 90 8 11 )MPH (916) 452-7021 FAX 4031519 sates@duralum.com 'oa "o' er" 10# L.L. 70 & 90 MPH ATTACHED OPEN LATTICE PATIOS } a = o m - Fx 3 MAX.coL. SPACING ON SLAB SEE FOOT- NOTE' 3" STEEL BEAM DBL.2"x6.5"x.024"BM DBLO'R 3"x86.5" tEA M BM OR "BEA DBL.3" x 8" BEAM 3" x 8" BM W/INSERT POST SPACING FTG, FT CUBE FTG. SIZE POST SPACING ON FTG. CUBE T'G. SIZE POST SPACING ON FTG. CUB FTG. SIZE POST SPACING ON FTG. CUBE FT'G. SIZE POST SPACING ON FTG. CUBE FTG. SIZE 70 & 90 MPH 70 & 90 MPH 70 & 90 MPH 70 8 90 MPH 70 8 90 MPH s 11'-4" 13'-7" 19 11'-7" 18 13'-3" 19 15'-7" 19 28'-9" 25 r 9'-8" 13'-1" 19 10'-11" 19 12'-3,. 20 14'-7" 20 28'-1" 26 e 8'-6" 12'-7" 20 10'-6" 19 11'-5" 20 13'-9" 20 27'-5" 27 s 7'-7" 12'-0" 21 10'-0" 20 10'-10" 21 13'-2" 21 26-10" 27 10' 6'-9" 11'-6" 22 9'-7" 20 10'-4" 21 12'-8" 21 26'-3" 28 11' 6'-2" 11'-2" 22 9'-2" 21 9'-10" 22 12'-4" 22 25'-9" 29 12 5'-8" 10'-3" 22 8'-10" 21 9'-5" 22 11'-9" 22 25'-3" 29 13• 5'-2" 9'-11" 22 8'-7" 21 9'-0" 23 11'-4" 23 24'4" 30 1a 4'-10" 9'-7" 23 8,4, 22 8'-8„ 23 11'-0" 23 24-4- 30 15• 4'-6" 9'-3" 23 8'-0" 22 8'-5" 24 10'-9" 24 23'-11 31 16, 4'-3" 9'-0" 23 7'-10" 22 8'-2" 24 10'4, 24 23'-6" 32 1r 4--0-- 8'-8" 23 7'-7" 22 7'-11" 24 10'-3" 24 23'-1" 32 18• 3'-9" 8'-7" 24 7'-5" 23 7'-8" 25 10'-0" 25 22'-9" 33 19 3'-7-' 8,4„ 24 T-3" 23 7'-5„ 25 91-91, 25 22'-5" 33 20' 3'-4" 8'-2". 24 7'-1" 23 7'-2" 25 9'-6" 25 22'-1" 33 21' 3'-2„ 8,-0" 24 6'-11" 23 6-11" 26 9'-3n 26 21'-5" 34 10' HT. OR LESS a = HT.=8' MAX. HT.=10• MAX. i2 POST TYPE POST TYPE SHEET 1 2 1 2 6'2 2 2 2 2 3 2 2 r 2 3 2 2 2 3 2 2 6 2 3 2 2 2 4 2 2 s 2 3 2 2 2 4 2 3 10, 2 4 2 2 7747 2 3 11.1_3-4 EXP. 9.30-2007 p 3-- 3 3 5 2 3 1r 2 4 2 3 3 5 2 3 13 3 4 2 3 3 5 2 4 1a• 3 5 2 3 3 5 2 4 u• 3 5 2 3 3 6 3 4 1s 3 5 2 3 4 6 3 4 17'. 3 5 2 4 4 6 3 4 18' 3 5 2 4 4 7 2 5 1s 3 6 3---4 4 7 3 5 29 4 6 3 4 4 7 3 5 21- 4• 6 4 3 5 FOOTNOTE: ' NOTE: FOX ENGINEERING INC. HEADER AND OR FOOTING SHOWN IN CUBIC INCHES SHEET FOOTNOTE: "SAMPLE" DATE: 11232002 JAMES G. FOX, CIVIL IL ENGINEER MIN. NO. OF POST REQUIRED SPACING WITHOUT SLAB. PRODUCTS, INC. FIGURE INDICATES 70 MPH --a ER -26400- FIGURE INDICATES 90 MPH MUSTEXCEED SEE ALTERNATE FOOTING TABLES QaoeESS1oN9 8269 ALPINE AVE., SACRAMENTO, CA 95826 22 OF 30 ALLOWABLE SLAB SPACING SHT. 9 FOR ATTACHED & G,p 70.9 8 110 MPH OR LESSER MUST BE USED SHT. 29 FOR FREESTANDING PMES + i FOOTNOTE:' NO. 21543 m COL. TYPES 1 =.024" SIDEPLATES, USE ON CONC. SLAB ONLY EXP. 9.30-2007 p COL. TYPES 2 =.032" SIDEPLATES, ON CONC. SLAB OR FOOTINGS. S COWL Y ,FOFCPLF I.C.C. E.S. EVALUATIONDRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: SHEET REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL IL ENGINEER SPACING TABLE 10. 20 8 30 "fDURALUM PRODUCTS, INC. ER -26400- SCALE:NONE 8060 TELEGRAPH RD.,DOWNEY, CA 90240 70190 FREESTANDING ANDATTACHED HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 22 OF 30 REVISED BY: K.K. & D.P. 562) 8061337 FAX:927-2509 loxeng@hotrnad.mm 70.9 8 110 MPH ( 116) 452-7021 FAX 403.1519 sales&—I.m.mm I.C.C. E.S. EVALUATION DRAWN BY: K.K. 10# L. L. 110 MPH ATTACHED OPEN LATTICE PATIOS 10' HT. OR LESS 10, 20830 ps1 DURALUM PRODUCTS, INC. SHEET ER -2640P MAx.coL. 3" STEEL BEAM DBL.2"x6.5x.024BM "" DBL.2"x6.5"x.032"BM OR 3"x8"BEAM DBL. 3" x 8" BEAM 3" x 8" BM W/INSERT REVISED BY: K.K. 8 D.P.10 MINIMUM NO. OF POST FOOTNOTE: ` } SPACING >- r H o ON SLAB POST SPACING CUBE FTG. SIZE POST CUBE FTG. POST CUBE FTG. POST CUBE FTG. POST 'G. 0::c o HT.=B' MAX. HT.=10' MAX. C13 SEE O N SPACING SIZE SPACING SIZE SPACING SIZE SPACING CU SIZE m 3 POST TYPE POST TYPE OTE' FTG. FTG. FTG. FTG. FTG. 1 2 1 2 s 11'-4" 11'-11" 20 9'-7" 19 10'-4" 19 12'-8" 25 19'-8" 33 s 5 3 6 3 r 9'-8" 10'-11" 21 9'-0" 19 10'-0" 20 12'-4" 26 19'-4" 34 T 5 3 7 4 IT 8'-6" 9'-11" 21 8'-7" 20 9'-8" 21 12'-0" 27 18'-10" 36 8' 6 3 7 4 s 7'-7" 9'-6" 22 8'-3" 20 9'-4" 21 11'-8" 28 18'-5" 37 9 6 4 8 4 10• 6'-9" 9'-0" 22 7'-10" 21 9'-1" 22 11'-5" 29 18'-1" 38 10' 7 4 9 5 11' 6'-2" 8'-8" 22 7'-6" 21 8'-10" 2211'4" 29 17'-8" 39 11' 8 4 9 5 1z 5'-8" 8'-4" 23 T-2" 21 8'-7" 23 11'-0" 30 17'-4" 40 12• 8 5 10 6 13' 5'-2" 8'-1" 23 7'-0" 22 8'-4" 2310'4" 31 17'-0" 40 13 9 5 11 6 1a• 4'-10"r7---4" 0" 23 6'-9" 22 8'-1" 23 10'-6" 31 16'-9" 41 to 9 5 11 6 1s• 4,.6n" 23 6'-6" 22 7'-11" 24 10'-3" 32 16'-5" 42 15• 10 5 12 7 1s 4'-3" 24 6'-4" 23 T-8" 2410'-0" 32 16'-2" 43 16' 10 6 13 7 17' 4'-0" T-2" 24 6'-2" 23 7'-5' 249'-9" 33 15'-11" 43 17• 11 6 14 8 to 3'-9" T -O" 24 6'-1" 23 7'-2" 24 9'_6" 33 15'-8" 44 18' 2 2 2 2 19 3'-7" 6-10" 25 5'-11" 23 6-11" 25 9'-3" 34 15'-5.. 44 19' 2 2 2 2 2IY 3'-4" 6'-8" 25 5'-9" 23 6'-8" 25 9'-0" 34 15'-3" 45 20' 2 2 2 2 21' 3-2" 1 6'-6" 25 5'-7" 23 6'-5" 25 g _g 34 15'-0" 45 21• 2 2 2 2 FOOTNOTE: ` NOTE: PROFESSIoN,9 HEADER AND OR M ES G.F MIN. NO. OF POST FOOTING SHOWN IN CUBIC INCHES P * i REQUIRED SPACING WITHOUT SLAB. NO. 21543 p MUST EXCEED SEE ALTERNATE FOOTING TABLES EXP. 9-342007 ALLOWABLE SLAB SPACING OR LESSER MUST BE USED SHT. 9 FOR ATTACHED & sr CIVIL r SHT. 29 FOR FREESTANDING FOOTNOTE: ` 9'E OF CAL%FO COL. TYPES 1 =.024" SIDEPLATES, USE ON CONC. SLAB ONLY COL. TYPES 2 =.032" SIDEPLATES, ON CONC. SLAB OR FOOTINGS. I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD = PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11232002 JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE 10, 20830 ps1 DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE:NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED HORIZ. WIND= 8269ALPINE AVE., SACRAMENTO, CA95826 1(916)452-7021 23 OF 30 NO' cmzoa 4 REVISED BY: K.K. 8 D.P.10 (562) 806-1337 FAX:927-2509 foxeng@hotmail.wm 70, 90 8 110 MPHJOB FAX 403-1519 sales@dumlum.com 20# L.L. 110 MPH ATTACHED OPEN LATTICE PATIOS } = r r o m 3 F MAx.coL. SPACING ON SLAB SEE FOOT- NOTE' 3" STEEL BEAM DBL.2"x6.5"x.024"BM ,DBL. R 3x"x.032"BM OR 3"8"BEAM DBL' 3" x 8" BEAM 3" x 8" BM W/INSERT POST SPACING ON FTG. CUBE FTG. S POST SPACING ON FTG. CUBE FTG. SIZE POST SPACING ON FTG. CUBE FTG. SIZE POST SPACING ON - FTG. CUBE FTG. SIZE - POST SPACING ON FTG. CUBE FTG: SIZE s 8'-11" 9'-9" 19 8'-6" 18 10'-0" 19 13'-10" 21 201-911 24 7 T-1" 9'-3" 20 8'-0" 19 9'_8" 20 12'-1" 21 20'-3" 25 Er 5-11" 8'-9" 20 T-7" 19 9'-4" 20 11'4" 22 19'-10". 26 9 5'-111 8'-4" 20 T-3" 20 9'-0" 21 11'-5" 23 19'-5" 27 10' 4'-5" 8'-0" 21 6-11" 20 8'-9" 22 11'-2" j 23 19'-0" 28 11' 3'-11" T-8" 21 6'-8" 20 8'-6" 22 10'-1111 24 18'-7" -29 12' 3'-6" 7'-5" 22 6'-5" 21 8'-3" 23 10'-8" 24 18'-3" 29 13' T-2" 7'-2" 22 6'-2" 21 8'-0" 23 10'-5" 25 17'-11" 30 14' - 6'-11" 22 6-0" 21 7'-9" 23 10'-2" 25 17'-7" 30 15' - 6'-8" 23 5'-10" 22 T-6" 23 9'-11" 26 17'-3" 31 1s _ 6'-6" 23 5'-8" 22 T-5" 24 9'-8" 26 17'-0" 31 17 _ 6,-4a 18 5'-6" 22 T-0" 24 9'-5" 26 16'-8" 1 32 FOOTNOTE:' HEADER AND OR MIN. NO. OF POST REQUIRED SPACING MUSTEXCEED ALLOWABLE SLAB SPACING OR LESSER MUST BE USED NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & SHT. 29 FOR FREESTANDING 10' HT. OR LESS r a = 99 93 r HT:=B' MAX. HT.=10' MAX. POST TYPE POST TYPE 1 2 1 2 s 5 3 6 3 7 5' 3 7 4 a 6 3 7 4 9 6 4 8 4 10' 7 4 9 5 1r 8 4 9 5 12' -8 5 10 6 73' 9 5 11 6 14' 9 5 11 6 1S 10 5 12 7 16' 10 6 13 7 17 11 6 14 8 NOTE: FOR 70 / 90 MPH MIN. POST, SEE 10# TABLE FOOTNOTE:' COL. TYPES 1 =.024" SIDEPLATES, USE ON CONC. SLAB ONLY COL. TYPES 2 =.032" SIDEPLATES, ON CONC. SLAB OR FOOTINGS. QaoFessy ES G.P S Z NO. 21543 m EXP. 9]62007 z S CIVR p WTFaFCAUF ,,e1 I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: ttn3rzooz JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE lo, 20 a 3o Psr DURALUM PRODUCTS, INC. SHEET ER -2640P SCALE: NONE g 8060 TELEGRAPH RD., DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED I HORIZ. WIND = I 8269 ALPINE AVE., SACRAMENTO, CA 95826 1(916)452-7021 24 OF 30 REVISED BY: K.K. 8 D.P. (562)806-1337.FAX:927-2509 (oxen hotmail.mm 70, 90 a 110 MPH FAX 4031519 sales@dumfum.00m 30# L.L. 110 MPH ATTACHED OPEN LATTICE PATIOS HT.=• MAX. MAx.coL. 3" STEEL BEAM DBL.2"x6.5"x.024"BM DBL.2R 3"x x.032" BM OR 8"BEAM DBL. 3" x 8" BEAM 3" x 8" BM W/INSERT } SPACING 5 3 6 3 7 5 3 7 4 g F 5 o ON SLAB POST SPACING CUBE FTG. SIZE POST SPACING CUBE FTG. SIZE POST SPACING CUBE FTG. SIZE POST SPACING CUBE FTG. SIZE POST SPACING CUBE FTG. ' SEEFOOT- FfG 8 ON 9 ON 12' ON 5 ON SIZE 13, NOTE 5 11 FTG. 14- FTG. 5 FTG. 6 FTG. B 6-0-- 8'-1., 18 7'-0" 17 8'-4" 18 10'-4" 19 17'-1" 23 7'-7" 18 6'-7" 17 8'-0" 1910'-0"20 16,4„24 7'-2" 19 6'-3" 18 7'-9" 19 9'-9,,21 15'-8" 24 7'-0" 19 6'-0" 18 7'-6" 20 21 15'-0" 25 9'-6„ m 6'-7" 20 5'-8" 19 7'-3" 20 9'-3n22 14'-6" 26 6,4,.205-6"19 7--On21 9'-0"23 14'-0" 26 6'-1" 20 5'-3" 19 6'-9" 21 8'-9" 23 13'-7" 26 5'-10" 21 5'-1" 20 6'-6" 21 8'-6"5'-7" 23 13'-4" 27 21 4'-11" 20 6-3" 22 8'-3" 24 13'-1" 27 10' HT. OR LESS m3 HT.=• MAX. HT=10• MAX. POST TYPE POST TYPE 1 2 1 2 a 5 3 6 3 7 5 3 7 4 g 6 3 7 4 s 6 4 8 4 10• 7 4 9 5 1r 8 4 9 5 12' 8 5 10 6 13, 9 5 11 6 14- 9 5 11 6 NOTE: ' FOR 70 / 90 MPH MIN. POST, SEE 10# TABLE FOOTNOTE:' COL. TYPES 1 =.024" SIDEPLATES, USE ON CONC. SLAB ONLY COL. TYPES 2 =.032" SIDEPLATES, ON CONC. SLAB OR FOOTINGS. FOOTNOTE: ' NOTE: FOX ENGINEERING INC. HEADER AND OR FOOTING SHOWN IN CUBIC INCHES PATIO COVER SYSTEM AS MFG. BY: MIN. NO. OF POST REPORT NUMBER REQUIRED SPACING WITHOUT SLAB. POST SPACING TABLE MUST EXCEED SEE ALTERNATE FOOTING TABLES QpOFESSIp49 ALLOWABLE SLAB SPACING SHT. 9 FOR ATTACHED 8 ES C.. yc OR LESSER MUST BE USED SHT. 29 FOR FREESTANDING , QPM + rt ' aoe w. r,Foaosr NO. 21543 m EXP. 9-362007 n REVISED BY: K.K. 8 D.P.10 (562) 806-1337 FAX:927-2509 foxeng@hotmail.mm 70, 90 8 110 MPH CIVIL p )Z OF CAlF01 I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD = PATIO COVER SYSTEM AS MFG. BY: SHEET REPORT NUMBER DATE: 1 V2 iL JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE 10, 20 8 30 Ds, DURALUM PRODUCTS, INC. 250E 30 ER -2640P SCALE:NONE 8060 TELEGRAPH RD.,DOWNEY, CA 90240 1101 REESTANDING ANDATTACHED HORIZ. WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 aoe w. r,Foaosr REVISED BY: K.K. 8 D.P.10 (562) 806-1337 FAX:927-2509 foxeng@hotmail.mm 70, 90 8 110 MPH (916) 452-7021 FAX 4031519 sales@duratum.mm 10# L.L. 70 & 90 MPH FREESTANDING OPEN LATTICE PATIO COVERS 12' HT. OR LESS VikorEs slob DBL.2"x6.5"x.032" BM. OR 3"XS"BEAM DBL. 2" x 6.5" x.024" BEAM DBL. 3" x 8" BEAM ti F1FSG,p 1 ' + 0 z 3" x 8" BM W/ INSERT 21543 p EXP. 9-3a2= SHT. 29 FOR FREESTANDING y F m o o:3 I' =MAX. POST SPACING MAX. POST HT. = 8 MAX POST HT. = 12' MAX. POST SPACING MAX POST HT. = 8' MAX. POST HT. = 12' MAX. POST SPACING MAX POST HT. = 8' MAX. POST HT. = 12' MAX POST SPACING MAX POST HT. = 8' MAX POST HT. =12' y _ 7 ~ Ln a ~ 70 90 MPH 70 90 MPH 70 90 MPH 70 90 MPH 70 90 MPH Z 70 90 MPH 70 90 MPH 70 90 MPH xcr MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN.MIN. POST TYPE CUBE FTG. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. I MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. s 12'-5"F G 24 26 / 26 28 11'-7" F F 24,,-"26 24 28 15'-7" G G 24 22 G G 2 28'-9" j 28 30 G J 3 34 s r 12'-2" F F 24 26 F G 26 28 0'-11" 24 26 F G 24 28 14'-6" 24,,--22 G G 2 28'-1" G G 28 30 G 3 3 r s 11'-11' F F 24,,,*'26 / 26 28 10-6„ F F 24 26 / 24,, -*'28 13,-6„ / 24-122 G G 26 30 27'-5" 28 30 G J 30 34 9 11'-8" F F 24,,-"26 F G 26 28 1p'-0" F F 24 26 / 24 28 12'-9'. G G 24 22 G G 26 30 26'-10„ G G 28 30 G 3 3 9 1a 11'-5„ F F 24--126 F G 26 28 9, 7„ F F 24 26 / 24 28 12'-1 . G F 24 22 F G 26 30 26'-3" 28 30 G. J 30 34 10' 1r 11'-2" F F 22 24 F G 26 28 9'-2" F 24 26 F G 24 28 11'-T, G F 24 22 F G 2 0 25'-9" 28,,--30 G 3 3 11, 1r 10'-11" F F 22 24 F G 24 26 8'-10" / 22 24 F G 24 24 11'-0" 22 24 F G 24 28 25'-3" G G ,- 30 G 3 30 32 12' 13' 10'-9„ F F 22 26 F G 24 26 8_7 22,,--24 F G 24,,-"24 1p'-7" 22,,--24 F G 24 28 24'-9, G G 28,--30 G J 30 32 13 14 10'-6" F F 22 22 F G -- 26 8.4' F4 22 24 F G 24 --*'26 1p'-2„ G F 22 24 F G 2 24 G G 28,.-'30 G G 332 14, 15 10'-4" F F 22 22 F G 24 26 8'-0" F F 22 24 F F 24--"24 9'-10„ G F 22 24 F G 2 23'-11' / 28,,,'30 G G 3 15 1s 10'-2" F F 22 22 F G 24 26 T-10., 22 24 24 24 9,-7„ G F 22 24 F G 2 23'-6" j 28 30 G G 30 32 1s 1r 10'-0„ 22 22 24 26 7.7" 22 24 24,,-"24 9'-3" G F 22,,--24 F 2 23'-1" 26,,-"'30 G G .3 17 1e 9'-10" F F 22 22 , 22 24 7' S„ 22 22 F 22 24 9,_0„ G F 22 24 F G 24 26 22'-9" G 26,"'30 G G 28 32 18' 19' 9'-8•. F F 22 22 F G 22 24 T-3„ F F 22,,",22 22,, -*'24 8,-9„ G F 22 24 F 2 22'-5" G 26--1130 G G 2!!8,,3--" 19' zo 9'-7" 22 22 F G 22 24 7'_1" 22 22 22 24 8'-7, 22 24 F G 24 26 22'-1" 26 30 G G 28 32 20 21' 9'-5„ F F 22 22 F G 22 2416'-11" F F 22 22 22 24 8'-4„ G F 22 24 F G 24 26 21'-5" 26,, -*"30 G G 28 32 21 NOTE: I.C.C. E.S. EVALUATION FOOTING SHOWN IN CUBIC INCHES VikorEs slob WITHOUT SLAB. N SEE ALTERNATE FOOTING TABLES ti F1FSG,p 1 ' + 0 z SHT. 9 FOR ATTACHED &NO. FOOTNOTE: "SAMPLE" 21543 p EXP. 9-3a2= SHT. 29 FOR FREESTANDING DATE: 11/238002 INDICATES POST & FTG. INDICATES POST & FTG. s clva. FOR 70 MPH FOR 90 MPH aP eF CAUF I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11/238002 JAMES G. FOX, CIVIL ENGINEER POST ITIG TABLE 10, 20 8 30 Psf DURAL PRODUCTS, INC. SHEET ER -2640P SCALE:NONE g 8060 TELEGRAPH RD.,DOWNEY, CA 90240 70/90 FREESTANDING gNDATTACHED HORIZ. WIND= IN 8269 ALPINE AVE.. SACRAMENTO, CA 95826 1(916)452-7021 26 OF 30 REVISED BY: K.K. & D.P. (562)80&1337 FAX:927.2509 (oxe hoheaiLmm 70, 90 & 110 MPH FAX 403.1519 soles@duralum.mm 10# L.L. 110 MPH FREESTANDING OPEN LATTICE PATIO COVERS 3" x 8" BM W/ INSERT DBL.2"x6.5"x.032" BM. OR 3"X8"BEAM DBL. 2" x 6.5" x.024" BEAM DBL. 3" x 8" BEAM MAX. y F x m o R 3 MAX, POST SPACING MAX. POST HT. = 8' MAX POST HT. = 12' MAX POST SPACING MAX. POST HT. = 8' MAX. POST HT. = 12' MAX POST SPACING MAX. POST HT. = 8' MAX. POST HT. = 12' 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. s 10'-4" G 28 G 30 9 -7 G 26 G 28 15'-7" G 28 G 30 r 10'-0" G 28 G 30 9'-0" G 26 G 28 14'-6" G 28 G 30 e 9'-8" G 28 G 30 8'-7" G 26 G 28 13'-6" G 28 G 30 9 9'-4" F 28 G 30 8'-3" G 26 G 28 12'-9" G 28 G 30 1 Tr 9'-1" F 28 G 30 7'-10" F 26 G 28 12'-1" G 28 G 30 11' 8'-10" F 28 G 30 7'-6" F 26 G 28 11'-7" G 28 G 30 12' 8'-7" F 26 G 28 7'-2" F 24 G 26 11'-0" G 28 G 30 13' 8'-4" F 26 G 28 7'-0" F 24 G 26 10'-7" G 28 G 30 14' 8.1 F 26 G 28 6-9 F 24 G 26 10'-2" G 28 G 30 1s 7'-11" F 26 G 28 6,-6„ F 24 G 26 9'-10" G 28 G 30 1e 7'-8" F 26 G 28 6'-4" F 24 G 26 9'-7" G 28 G 30 1r 7'-5" F 26 G 28 6'-2 F 24 G 26 9'-3" G 26 G 28 19 7,-2„ F 26 G 26 6,-1,. F 24 G 26 9.4" G 26 G 28 19 6'-11" F 24 G 26 5'-11' F 24 G 24 8'-9" G 26 G 28 2(Y 6'-8" F 24 G 26 5'-9" F 24 G 24 8'-7" G 26 G 28 21' 6'-5" F 24 G 26 5'-7" F 24 G 24 8'-4" G 26 G 28 NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & SHT. 29 FOR FREESTANDING 12' HT. OR LESS 3" x 8" BM W/ INSERT } MAX. MAX. MAX. POST HT. = 8' POST HT. = 12' F POST PACING m o 3 110 MPH 110 MPH MIN. CUBE MIN. CUBE HORIZ.WIND= 8269 ALPINE AVE.. SACRAMENTO, CA 95826 W. GF02 s 4 POST FTG. POST FTG. 70, 90 8 110 MPH 916 452-7021 FAX 4031519 sales duralum.mm ( ) TYPE TYPE 12'-8" G 32 1 34 a 12'-4" G 32 1 34 r 12'-0" G 32 J 34 s G 32 1 34 9 G 32 1 34 10' 11'-3" G 32 J 34 11 11'-0" G 30 J 32 12' 10'4" G 30 1 32 13 10'-6" G 30 G 32 14' 10'-3" G 30 G 32 15' 10'-0" G 30 G 32 16' 9'-9" G 30 G 32 17' 9'-6" G 30 G 32 19 9'-3" G 30 G 32 19 9'-0" G 30 G 32 20- 8'-9" G 30 G 32 21' QpOFESS)O PMESG., q 4L NO. 21543 m xI EXP. 9-302007 3} CIVI% P 4TFOFCAL I.C.C. E.S. EVALUATION DRAWN BY: K.K. - FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: SHEET EE REPORT NUMBER DATE: 11/232002 JAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE 10, 20 8 30 pst DURALUM PRODUCTS, INC. 27 30 ER -2640P SCALE:NONE 8060 TELEGRAPH RD., DOWNEY. CA 90240 110 FREESTANDING ANDATTACHED HORIZ.WIND= 8269 ALPINE AVE.. SACRAMENTO, CA 95826 W. GF02 s 4 REVISED BY: K.K. B D.P. (562) 806.1337 FAX:927.2509 (oxengQhotmail.mm 70, 90 8 110 MPH 916 452-7021 FAX 4031519 sales duralum.mm ( ) 20# L.L. 110 MPH FREESTANDING OPEN LATTICE PATIO COVERS 3" x 8" BM W/ INSERT DBL.2"x6.5"x.032" BM. OR 3"x8"BEAM DBL. 2" x 6.5" x.024" BEAM DBL. 3" x 8" BEAM z x m o_ MAX, POST SPACING MAX. POST HT. = 8' MAX POST HT. = 12' MAX. POST SPACING MAX POST HT. = 8' MAX. POST HT. = 12' MAX POST SPACING MAX. POST HT. = B' MAX. POST HT. = 12' 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN, POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST .TYPE CUBE FTG, MIN. • POST TYPE CUBE FTG. J 36 .G 28 G 30 8'-6" G 26 G 28 11'-5" G 28 G 32 T 8'-9" G 28 G 30 8'-0" F 26 G 28 10'-7" G 28 G 32 s 8'-7" G 28 G 30 7-7" F 26 G 28 9'-11" G 28 G 32 s 8'-5" G 28 G 30 T-3„ F 26 G 28 9'-4" G 28 G 32 10' 8'-3" G 26 G 28 6-11" F 24 G 26 8'-10" G 28 G 30 1r 8'-1" F 26 G 28 6'-8" F 24 G 26 8'-5" G 28 G 30 1z T-11" F 26 G 28 6!-5" F 24 G 26 8'-1" G 28 G 30 13' T-9" F 26 G 28 6'-2" F 24 G 26 7'4" F 28 G 30 14' 7'-7" F 26 G 28 6-0" F 24 G 26 T-5" F 28 G 30 16 T-5" F 26 G 28 5'-10" F 24- G 26 T-2" F 28 G 30 16! T-4" F 26 G 28 5'-8" F 24 G 26 T-0" F 28 G 30 1T T-3" F 26 G 28 5'-6" F 24 G 26 6'-9" F 28 G 30 NOTE: FOOTING SHOWN IN CUBIC INCHES WITHOUT SLAB. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED & - SHT. 29 FOR FREESTANDING 12' HT. OR LESS 3" x 8" BM W/ INSERT FOX ENGINEERING INC. ~ °0 Q 3 MAX. POST SPACING MAX. POSTPOST HT. = 8' MAX. HT. = 12' 110 MPH 110 MPH MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. 20'-9" G 32 J 36 s 20'-3" G 32 J 36 r 19'-10" G 32 . J 36 g 19'-5" G 32 J 36 g 19'-0" G 32 J 34 10' 18'-7" G 32 J 34 11' 18'-3" G 32 J .34 1z 17'-11" G 32 J 34 13 17'-7" G 30 J . 32 14' 17'-3" G 30 J 32 15 17'-0" G 30 J 32 16! 16'-8" G 1 30 J 32 1r QµOFESSI0 W MES G., 9 i NO. 21543 1" EXP. 9-362007 z S clvR •97F OFCALFOP I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGINEERING INC. LIVE LOAD= PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER DATE: 11/232002 FJAMES G. FOX, CIVIL ENGINEER POST SPACING TABLE 10. 20 8 30 psf DURALUM PRODUCTS, INC. SH] SHEET ER -2640P SCALE:NONE E 8060 TELEGRAPH RO.,DOWNEY, CA 90240 110 FREESTANDING ANDATTACHED HORIZ WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 28 OF 30 0 as7a REVISED BY: K.K. 9 D.P. 562 806-1337 FAX:927.2509 (oxen hotmail.mm 70,90 8 110 MPH (916) 452.7021 FAX 403-1519 sales@dumIum.mm 30# L.L. 110 MPH FREESTANDING OPEN LATTICE PATIO COVERS 3" x 8" BM W/ INSERT DBL.2"x6.5"x.032" BM. OR 3"x8"BEAM DBL. 2" x 6.5" x.024" BEAM DBL. 3" x 8" BEAM MAX. POST HT. = 12' . ED 3POST ~ MAX SPACING MAX. POST HT. = 8' MAX POST HT. = 1 z MAX. POST SPACING MAX. POST HT. = 8' MAX. POST HT. = 12' MAX POST SPACING MAX. POST HT. = 8' MAX. POST HT. = 12' 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH 110 MPH MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE FTG. s 7'-5" F 26 G 28 7'-0" F 24 G 28 9'-5" G 28 G 30 r 7'-1" F 26 G 28 6'-7" F 24 G 28 8'-9„ G 28 G 30 Er 6'-9" F 26 G 28 6'-3" F 24 G 28 8'-2" G 28 G 30 9 6'-6" F 26 G 28 6'-0" F 24 G 28 T-8" F 28 G 30 10, 6'-3" F 24 G 28 5'-8" F 24 G 26 T-4" F 26 G 28 11' 6'-1" F 24 G 28 5.-6n F 24 G 26 7'-0" F 26 G 28 1z 5'-10" F 24 G 26 5'-3" F 24 F 24 6'-8" F 26 G 28 F 24 G 26 5'-1" F 24 F 24 6'-5" F 26 G 28 F 24 1 F 26 4'-11" F 1 22 1 F 1 24 1 6'-2" F 1 26 1 G 1 28 12' HT. OR LESS 3" x 8" BM W/ INSERT FOOTING MAX. SPACING MAX POST HT. = 8' MAX. POST HT. = 12' y 0= x it 3 ~ 110 MPH 110 MPH MIN. POST TYPE CUBE FTG. MIN. POST TYPE CUBE F7G. W/ NO SLAB G 30 G 32 s 164" G 30 G 32 r 15'-8" G 30 G 32 s 15'-0" G 30 G 32 9 14'-6" G 30 G 32 10' 14'-0" G 30 G 32 11• 13'-7" G 28 G 30 12' 13'-4" G 28 G 30 13, 61"SQ. G 28 G 30 14' PROFESSIO ESC.. p 9 i NO. 21543 m EXP. 930-2007 P CML p 9TEOFCpUF I.C.C. E.S. EVALUATION ALTERNATE FREESTANDING FOOTING CUBE FOOTING SO. x 18' THICK CUBE FOOTING CUBE FOOTING SO. x 18' THICK CUBE FOOTING WINO SLAB W/ NO SLAB W/ SLAB W/ NO SLAB W/ NO SLAB W/ SLAB 20" 23" SQ. 18" 38" 50" SQ. 36" 22" 26" SQ. 20" 40" 51"SQ. 38" 24" 30" SQ. 22" 42" 53" SQ. 40" 26" 33" SQ. 24" 44" 55" SQ. 42" 28" 37" SQ. 26" 46" 56" SQ. 44" 30" 41"SQ. 28" 48" 57" SO. 46" 32" 45" SQ. 30" 50" 58" SQ. '48.1 34" 47" SQ. 32" 52" 61"SQ. 50" 36" 48" SQ. 34„ 54„ 64" SQ. 52„ PROFESSIO ESC.. p 9 i NO. 21543 m EXP. 930-2007 P CML p 9TEOFCpUF I.C.C. E.S. EVALUATION DRAWN BY: K.K. FOX ENGEERING INC. LIVE LOAD = PATIO COVER SYSTEM AS MFG. BY: REPORT NUMBER GATE: 11232002 101AMESG.11 FOX,CNIL ENGINEER POST SPACING TABLE 10,zo E 30 psr DURALUM PRODUCTS, INC.ER-2640P SHEET SCALE: NONE 8060 TELEGRAPH RD., DOWNEY, CA 90240 110 FREESTANDING HORIZ, WIND= 8269 ALPINE AVE., SACRAMENTO, CA 95826 29 OF 30 REVISED BY: K.K. 8 D.P. 562 806-1337 FAX:927-2509 (oxen (athotmail.mm ANDATTACHED 70, 90 8 110 MPH (916) 452-7021 FAX 403.1519 sales@duralum.com roes ATTACHMENT DETAIL FOR INSULATED STRUCTURAL SANDWICH PANEL ALUM. ALLOY 3004-H36 SKIN 2.740" ROOF SLOPE SHALL BE 1/4": 12" MIN. 3.0" • 8.0" JAMES G. FOX, CIVIL ENGINEER ALUY 6063 -T63 -T6 3.200" T=.060 FASCIA WIND 3„ .024" 181-0" 1Y-9" 10,-91 .032" 14'-5" 12'-4" PANEL CONNECTIONS HORIZ. WIND= 8289ALPINEAVE.,SACRAMENT0. CA 95826 1(916)452-7021 .042 DESIGN S.M.S _ 70 MPH #14 (G) 12" O.C. .024" 21,-4„ 15'-1" OR4.200" WALL FASTENERS APPROVED 3" 70, 90 8 110 MPH' 4„ — 90 MPH #14 @ 12" O.C. .032" 22'-0" 17'4" 14'-3" SEE TABLE INSUL. ROOF PANEL 110 MPH #14 @ 8" O.C. NOTE: #14 SMS SHALL HAVE 3" OR 4" STRUCTURAL SANDWICH PANEL WIND AT 2x FASCIA SEE ELITE ALUMINUM CORP. I.C.C. ER -5658 AT MASONRY OR A MIN. 1" PEN. INTO HEADER 16" O.C. FOR PANEL SPANS AND DESCRIPTION DETAILS #10 SMS T8B 1.880" LL=10 LL=20 LL=30 LL=10 LL=20 LL=30 LL=10 LL=20 AT 12" O.C. 70 I.C.C. APPROVED 8" BEAM C. 3" OR 4" HANGER CHANNEL HEADER BEAM AND ENCLOSURE WALL SYSTEMS OPTIONAL DECORATIVE FASCIA MUST BE I.C.C. APPROVED UNDER 1997 U.B.C. (WOOD, ALUM. OR HARD80RD) \ #14 S.M.S. SEE TABLE ABOVE r PANEL TO HEADER BEAM CONN EXTRUDED i IR3' GUTTER\J NALL FASTENERS SEE TABLE BELOW P EDGE NAL RAIN GUTTER PANEL SPAN TABLE ORAWNBY:K.K. FOX ENGINEERING INC. PANEL SKIN INCH INCH LL =10 LL=20 LL=30 JAMES G. FOX, CIVIL ENGINEER OPTIONAL NON-STRUCTURAL FASCIA OURALUM PRODUCTS, INC. 3„ .024" 181-0" 1Y-9" 10,-91 .032" 14'-5" 12'-4" PANEL CONNECTIONS HORIZ. WIND= 8289ALPINEAVE.,SACRAMENT0. CA 95826 1(916)452-7021 OF 30 3C REVISED BY: K.K. B D.P. .024" 21,-4„ 15'-1" 12'4" 70, 90 8 110 MPH' 4„ — .032" 22'-0" 17'4" 14'-3" HANGER / RAIL FASTENER TO FASCIA, WALL ( STUD, MASONRY OR CONC.) WIND AT 2x FASCIA AT WOOD STUD AT MASONRY OR DESIGN W/ SIMPSON A35 16" O.C. CONCRETE LL=10 LL=20 LL=30 LL=10 LL=20 LL=30 LL=10 LL=20 LL=30 70 A C C. E H H J J K 90 B C C E H H J J K 110 D C C G H H J J K DESCRIPTION OF LAG SCREW w0 A=1/4"0x11/2"@12"O.C. E=3/8"0x21/2"@16"O.C. J=1/4"0x11/8"@16"A.B. F¢w B=3/8"0x11/2"@16"0.C. F=7/16"Ox21/2"@16"O.C. K=1/4"0x11/8"@12"A.B. ui fnICI- C=3/8"0x11/2"@12"O.C. G=7/16"0x21/2"@12"O.C. LL55r ' D=7/16"0x11/2"@12"O.C. H=3/8"0x21/2"@12"0. C. - PANEL TO PATIO ENCLOSURE CONN. #14 S.M.S. SEE TABLE ABOVE 1 'UL OF INSULATED ROOF PANEL INSULATED ROOF PANEL TO I.C.C. APPROVED TO I.C.C. APPROVED BEARING WALL SYSTEM NON-BEARING WALL SYSTEM NOTE: PANELS SHALL BE ELITE ALUMINUM CORP. I.C.C. ER -5658 OR APPROVED EQUAL THE PANELS USED WITH THE PATIO COVER STRUCTURES RECOGNIZED IN THIS EVALUATION REPORT MUST HAVE A CURRENT ICC -ES EVALUATION REPORT FOR USE WITH PATIO COVERS COMPLYING WITH APPENDIX CHAPTER 31, DIVISION 111, OF THE U.B.C. WHICH MUST BE SUBMITTED WITH ER -2640-P WHEN INSULATED ROOF PANEL IS USED. 1-1 " NO. 21543 EXP. 9-304007 NOTE: ZgE I ALL COMPONENTS ARE INTERCHANGABLE UNLESS OTHER WISE NOTED .C.C. E.S. EVALUATION ORAWNBY:K.K. FOX ENGINEERING INC. LIVE LOAD, PATIO COVER SYSTEM AS MFG. BY: EPORT NUMBER DATE:11/232002 JAMES G. FOX, CIVIL ENGINEER INSULATED ROOF 10.20&30psf OURALUM PRODUCTS, INC. HEET R-2640 SCALE: NONE R BO60TELEGRAPH RD.. DOWNEV, CA 90240 PANEL CONNECTIONS HORIZ. WIND= 8289ALPINEAVE.,SACRAMENT0. CA 95826 1(916)452-7021 OF 30 3C REVISED BY: K.K. B D.P. (562)80&1337 FAX:927-2509 foae holmall— 70, 90 8 110 MPH' FAX403.1519 58183@ L, — s