Loading...
PAT (07-1692)79971 Memorial Pl 07-1692 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number- 07-00001692 Property Address: 79971 MEMORIAL PL APN: 604-501-012-19 -24197 - Application description: PATIO COVER RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 7980 Applicant: c&ty/ 4 4 Q" ', Architect or Engineer: BUILDING & SAFETY DEPARTMENT. BUILDING PERMIT Owner: JOYCE KAY/VAN ARABIAN 79971 MEMORIAL PLAC LA QUINTA, CA 9225a ------------------- -- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License -is in full force and effect. License Class: - License No.: - Date: Contractor OWNER -BUILDER DECLARATION - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any a scant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars'($ 500).: 1 ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I ' 1 I am exempt under Sec. B.&P.C. for this reason Date: "l l_..Ovvne CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the . work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: S Lender's Address: LQPER1111T VOICE (760) 777-7012 ' FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Dater 6/11/07 Contractor. ,t• Owner L ------------ ----.-----_- ---------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ' Code, for the performance of the work for which this permit is issued. My workers_' compensation . insurance carrier and policy number are: Carrier Policy Number certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section C 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Date:- t Applican c WARNING: FAILURE TO SECURE WORKERS'. COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF_COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this, application, the owner,'and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit. issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that Irhave read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for ins ion purposes. t _ Dat" D - Signature (Applicant or Agent): Application Number 07-00001692 Permit PATIO COVER PERMIT Additional desc . Permit Fee 108.00 Plan Check Fee 70.20 ' Issue Date . . Valuation . . . 8645 Expiration Date .12/08/07 Qty Unit Charge Per Extension BASE FEE 45.00 7.00 9.0000 THOU BLDG 2,001-25,000 63.00 - ----_- --- ------ Special Notes and Comments 6005E BUILTUP PATIO COVER [CITY SPEC] VERIFY PROPOSED SETBACKS IN FIELD [RL ZONE] June 11, 2007 1:38:48 PM AORTEGA Fee summary Charged Paid Credited Due Permit Fee Total_ 108.00 .00 .00 108.00 Plan Check Total 70.20 .00 - .00 -70.20 Grand Total 178.20 .00 .00 178.20. LQPEIMIT - • - - . ' Bin # City -of .La Quinta Building ex Safety Division P.O.-'Box 1504, 78-495 Calle Tampico r. La Quinta, CA 92253- (760) 777-7012 Building Permit Application and Tracking Sheet - # Permit .# V + ' Project Address: L Owner's Name: S •A. P. Number: Address: ee- Legal Description: ,. Contractor;, Address: City, ST, Zip: Telephone: - Project Description: City, ST, Zip: Telephone: State Lic. # : City Lic. #: ' Arch., Engr., Designer:` Address: ,. City, ST, Zip: Telephone: , , State Lic. #:. Name of Contact Person: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: #Units: Telephone # of. ct Person: Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACMG , PERMIT FEES . Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan.) Plans resubmitted Mechanical - Grading, plan 2"" Review, ready for corrections/issue Electrical ; • Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ' H.O.A. Approval Plans resubmitted Grading r IN HOUSE:- ''" Review, ready for corrections/issue Develo er Im a Planning Approval Called Contact Person'A• 'A—PICITY OF LA UUM. 'A Pub. Wks. A r pp ' Date of permit issue,; Lp G I T. School Fees I- ' To IF, BY. •. .•_.. "// SNII. O ., RAFTER SIZE AND SPACING SPECIFY ROOFING AND'SHEATHING OR OPEN LATTICE .• (SEE ROOFING NOTE ON REVERSE) ROOF PITCH CONTINUOUS LEDGER (SAME SIZE AS RAFTERS) HEADER SIZE I 'T' AND 'L' STRAPS x 6"xE'xt"xI18" WITH I (4) 16d NAILS OR BOLT y I u RAFTER SPAN: J i= POST SPACING: O.H.. W O.H. - v . o• OVERALL LENGTH:_ • a OVERALL LENGTH: • . POST SIZE: Vn r ;; REAR SETBACK SIDE SETBACK (4'x MIN.). 4tCo+ y .2000 P.S.I CONCRETE -+I 1 FINISH GRADE FINISH GRADE L_ J I I LJ ..MIN. 12" x 12" FOOTING I I _ i2" BELOW GRADE L—J PROVIDE T" CLEARANCE BETWEEN POST 'AND NOTE: CONCRETE OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA VIA ONE 1/4" x 5' LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL U—STRAP OR ANGLE 3/8" x 5 LAG SCREWS INTO STUDS AT.. 16' O.C. NON—CORROSIVE PLATE RASE CONTINUOUS LEDGER (4)— :16d NAILS OR 'BOLT (4)— 16d NAILS OR BOLT . JOIST' HANGER. OR SOLID BLOCKING NAIL RAFTER TO BLOCKING PROVIDE 1" CLEARANCE BETWEEN POST AND 'CONCRETE' II BUILDING DEPARTMENT APPROVAL BELOW ANCHOR BOLT (EMBED C'W OC .7"• MIN. INTO CONCRETE) WILDING.-& Sq 'TA 'APPIRODEPT., TYPICAL PATIO 'COVER VEDDATE of APPLICATION CONSTRUCTioN _` - Fp . OWNER'S NAME' DA ;_a 7Y STREET ADDRESS o / CITY. ST ZIP TELEPHONE H.O.A. APPROVAL X Iz Q' Q Q v v v RAFTER SPAN. TABLE meq-' <` q, GRADING RULES ` C'` ° ALL CONSTRUCTIOtN 'SHA.LL CONFORM Ps 20-7o TO .THE PROVISION'S OF THE (FEET .& INCHES) pJ oJ t, . pJ ' c; 2001 CALIFORNIA BUILDING CODE. 2x4 16" O.C. 1o'-6"9 _5 7•_-" SUPPLEMENTAL NOTES: I 24" —6" 8'-0" 6'=0" T -3-- 2x6 16". O.C. 14'-0" 10'-9" 13'-0" . ------------ 10'-6" N A 2x8 16" O.C. 1 '-0" :17'-0". • 13'- " 16'-Q" . 24" 1-3'-0" 11' - ` N/A N q NOTES: 1. 32" RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID PATIO COVERS (NOT LATTICE) RAFTER SPAN 1S LIMITED TO 16,-0" USING THIS STANDARD: LATTICE ROOF BUILT—UP ROOF HEADERS HEADERS I DOUGLAS FIR N0. 1 DOUGLAS FIR' N0. 1 SIF TPANESPAN ROOFI4r.4 .4'-0" A: BUILT -gip, ROLLED ROOF: SLOPE TO DRAIN:4x6 84x8 1 1 6'-04x10 X8 8'-0" B. ROCK. ROOF: 3;i12 MAXIMUM PITCH: 14'-0' 4x10 10'-0' 4x12 'I 7'- 4x12— 1?' -0' 16x8 14'-0" 6x8 6x 10 17 0' }— — —0 6x10 14._0,.