Loading...
RC (06-4133)51025 Avenida Mendoza Ste 201 06-4133 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 06-00004133 ' 'Property Address: 51025 AVENIDA MENDOZA APN: 773-073-012- - Application description: REMODEL - COMMERCIAL Property Zoning: VILLAGE COMMERCIAL Application valuation: 9000 T4ht " -,. BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: STE 201 PATRICK & MONICA ADAMS 45795 PUEBLO ROAD 38938 ELMWOOD ST RANCHO MIRAGE , CA, I 9,'"_2=7= Applicant: Architect or Engineer: Ocher z'-kowieS6,sw/A.W1 G //99/ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: _ License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by a y pplicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( I; as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who -builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _) I am exempt under Sec. , B.&P.C. for this reason Date: -- 2=2 979l Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPE%IIIT Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 CITY O[: LA QWNTA Date:. 12/28/06 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700,of the Labor Code, I shall rthwith co ly wit thos provisi'ns. . WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and -for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, an hereby a thorize r presentatives of this /`' gory to enter ypon the ve-mentioned prop ert c JsesA.A.. .... ate: /i i ture (Applicant or Agentl: Application Number . . 06-00004133 ------ Structure Information OFFICE T.I. SUITE 201 ----- Other struct info . . . . . CODE EDITION O1BMP04E0SEN FIRE SPRINKLERS YES MIXED-USE OCCUPANCY B OCCUPANT LOAD 9.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 991.00 Permit . . . BUILDING PERMIT Additional desc OFFICE SUITE 201 T.I. Permit Fee . . . . 108.00 Plan Check Fee 70.20 Issue Date . . . . Valuation . . . . 9000 Expiration Date 6/26/07 Qty Unit Charge Per Extension BASE FEE 45.00 7.00 9:0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 63.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 39.45 Plan Check Fee 9.86 Issue Date Valuation . . . . 0 Expiration Date 6/26/07 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 21.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 9.45 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/26/07 Qty . Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 ----------------------------------------------------------- EA MECH VENT INST/ DUCT ALT ----------------- 4.50 Permit PLUMBING Additional desc . . Permit Fee . . 46.50 Plan Check Fee 11.63 Issue Date . . . . Valuation 0 Expiration Date . . 6/26/07 LQPEIL\1IT Application Number . . . . . 06-00004133 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA - PLB FIXTURE 6.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP ------------------ 3.00 ---------------------------------------------------------- Special Notes and Comments MORTGAGE OFFICE T.I. @ 2ND FLR. SUITE 201.[BARRINGTON MORTGAGE]"B" OCC. TYPE V -N CONSTRUCTION, 9 OCCUPANT LOAD.2001 CBC,CMC,2004.CEC, 2005 ENERGY CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 7.02 ENERGY REVIEW FEE 7.02 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 213.45 .00 .00 213.45 Plan Check Total 96.57 .00 .00 96.57 Other Fee Total 14.04 .00 .00 14.04 Grand Total 324.06 .00 .00 324.06 LQPM111T 11 Building P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO Address 5' I -f 2s- Ave.F—ocIZQ LA QUINTA, CALIFORNIA 92253 Owner 1,.s BUILDING: TYPE CONST. "� OCC. GRP. (D Fl -fl C lE Mailing ' Address �t 3�TE�m vom n s—,-- A.P. Number 7t3 3 073 i o I ANCt� Zip Tel. Legal Description LoTs ¢-2 � , F� OF s4AIT/ZJ eaR�t--h fitk� 70 760 3aY-S'a 9 � ✓m 6144, wTq ntractor Project Description W NL12 a LL4-A-- t2_T Address !t✓v�T & Classif. Arch., Engr., Designer I Zip Lic. Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ TBA, ANT 'V m PRo Ue n_ , ,.T V '%Lic. # ��- - `� ' LIC SED CONTRACTOR'S DECLARA q� _~ 0 TION I hereby affirm that I a ensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 0 usiness and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires-the-aDo1icanLfnt-such --it m fa. o er.......a ...e........... �_.,.,,. - APPILICANT: DO NOT WRITE BELOW THIS LINE # SubmitI Req'd Rec'd TRACKING la Sets Plan Check submitted T� Structural Cities. Reviewed, ready for corrections Z / O! Truss Calcs. Called Contact Person z f Energy Cales. A10 Plans picked up 18 Flood plain plan Plans resubmitted �Z Grading. plan 2" Review, ready for correctio issue Subcotitactor List Called Contact Person �Z Grant Deed Plans picked up H.O.A. Approval Plans resubmitted IN HOUSE:- '"' Review, ready for correctionstissue Planning Approval Called ,Contact Per Pub. Wks. Appr Date of rmit issue I School Fees PERMIT FEES Item Plan Check Deposit Plan Check Balance Construction Mechanical Electrical Plumbing S.M.I. Grading Developer Impact Fee A.I.P.P. Amount I I I I I I I Total Permit Fees 1 324. to G. John R. Hawkins Fire Chief Proudly serving the Unincorporated Areas of Riverside County and the Cities of: Banning ,. Beaumont :- Calimesa 4. Canyon Lake Coachella Desert Hot Springs Indian Wells Indio .; Lake Elsinore .; La Quinta 4. Moreno Valley .; Palm Desert e• Perris e. - Rancho Mirage 4. San Jacinto 4. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire_ Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 December 22, 2006 Patrick Adams 38938 Elmwood Street Rancho Mirage, CA 92270 RE: TENANT IMPROVEMENT PLAN CHECK LAQ-06-TI-109 / Adams Building at 51025 Avenida Mendoza #201, La Quinta, CA. You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT: It is prohibited to use/process or store any materials in this occupancy that would classify it as an "H" occupancy per Sec: 307 of the 2000 UBC. THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Install door hardware and exit signs as per Chapter 10 of the 2000 UBC. Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard of the Knox Company. Plans must be submitted to the Fire Department for approval of mounting location/position and operating standards. Special forms are available from this' office for the ordering of the Key Lock Boxes. This;form must be authorized and signed by this office for the correctly coded system to be purchased. If the building/facility is protected with a. fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. ELECTRICAL PANEL BOX: All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. OTHER REQUIREMENTS: EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 T Approved building address shall be placed in such a position.a to be plainly visible and legible from the street. Said numbers shall contrast with their background. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections..A re -inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. Sincerely, Tracy Hobday Chief Fire Department Planner By: Sonia Cooley Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 Certificate of Occupancy U = • II,,II _ i isa G4 OFT9 Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was . in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 51-025 AVENIDA MENDOZA, STE. 201 Use classification: COMMERCIAL Building Permit No.: 06-4133 Occupancy Group: B Type of Construction: VN Land Use Zone: VC Owner of Building: PATRICK ADAMS Address: 51-025 AVENIDA MENDOZA City, ST, ZIP: LA QUINTA, CA 92253 ---- By: KIRK KIRKLAND Date: JANUARY 29, 2007 Building Official POST IN A CONSPICUOUS PLACE 7 I TITLE 24 REPORT Title 24 Report for: 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bld . 2nd Flr. #201 51-025 Avenida Mendoza La Quinta, CA Project Designer: 7 Report Prepared By: Marc Farmer Energy and Duct Systems 40492 Clark Drive Hemet, CA 92544 (951) 925-0100 Job Number: 03-135 Date: 11/27/2006 LA QUINTA '1`b ary& SAFETY DEPT. L / P ROVED FGii CONSTRUCTION . BCo'413 rTT'9 1 NOV 2 9 2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I EnergyPro 4.3 by EnergySoft Job Number. 03135 User Number. 1268 1 q OFRCIE 66f7 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM Envelope Mandatory Measures Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary 1 2 3 15 16 17 19 EnergyPro 4.3 by EnergySoft Job Number. 03.135 User Number: 1268 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERFA PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Flr. #201 11/27/2006 PROJECT ADDRESS Marc FarmerZl--Z,7-OC. BUILDING CONDITIONED FLOOR AREA 51-025 Avenida Mendoza La Quinta The Principal Designer hereby certifys that the proposed building design rellresented in this set of construction documents is CLIMATE ZONE 1 15 PRINCIPAL DESIGNER - ENVELOPE ® TELEPHONE Building Permit # DOCUMENTATION AUTHOR PHASE OF CONSTRUCTION TELEPHONE Checked by/Date Energy and Duct Systems EXISTING + ADDITION/ALTERATION 951 925-0100 Enforcement AgencyUse , GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR DATE OF PLANS DATE Marc FarmerZl--Z,7-OC. BUILDING CONDITIONED FLOOR AREA 991 Sq.Ft. The Principal Designer hereby certifys that the proposed building design rellresented in this set of construction documents is CLIMATE ZONE 1 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL t 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION Ej NEW CONSTRUCTION ADDITION ® EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE Marc FarmerZl--Z,7-OC. The Principal Designer hereby certifys that the proposed building design rellresented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with thi permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. t 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. n ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. . n n 3. 1 affirm that 1 am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual..) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRI E VELO D IGNER - NAME SIGNATURE LIC. NO. DATE LIGHTING COMPLIANCE Indicate Iogatio 01 plans of Note Block for Mandatory Measures LTG -1, LTG -2 Required Forms PRINCIP L(GHTINd DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIP SIGNER -NAME SIGNATURE LIC. NO. DATE CHNIC EnergyPro 4.3 by EnergySoft User Number 1268 Job Number. 03-135 Page:3 of 19 1 AW PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME DATE 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 1 11/27/2006 ENERGY COMPONENT Standard Design Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type Proposed Design sqR sgft. sqft. Compliance Margin 1 1 10 Standard__ _ ■Proposed Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: Percent better than Standard: 1.88 2.02 -0.14 1J7C-WV "'"R'H"im """`"" _ DHW P�ewnS "� 0 20 40 60 80'100 120 140 160 180 2o0 220 kBtufsgft-n 206.81 231.07 -24.25 41.00 40.86 0.14 0.00 0.00 0.00 0.00 0.00 0.00 17.90 17.90 0.00 79.61 51.88 27.73 91.54 91.54 0.00 0.00 0.00 0.00 438.75 435.27 3.48 process) Roof 0.8% ( 0.8% excluding Building Orientation Number of Stories Number of Systems Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 991 0 0 Natural Gas sqR sgft. sqft. 2 1 1 470 so. Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N 470 so. 70 sgft. 14.9% Left Elevation E) 380 so. 60 sgft. 15.8% Rear Elevation s o SCA o SCA 0.0% Right Elevation 3101 sgft 48 sgft 15.5% Total 1,160 sgft. 176 sgft. Roof 991 sgft.sgft. 0.0% Standard Proposed LEED,.NC v22 Energy & Atmosphere Credit Lighting Power Density 1.200 w/sgt 0.782 wisca Savings vs. Title 24: 0.79% Prescriptive Env. Heat Loss 234 Btuth 287 Btuth EAc1 Credit: 0 Points Prescriptive Env. Heat Gain 23,217 Btum-F 28,356 Btum-F Remarks: RUI11111Ud1N/11 I1111C: 11/L//VO 10:.74:�F0 1CYI1 VYUC. I IOYV/.7L00 EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number. 03-135 Page:4 of 19 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME DATE ` 991 Sa. Ft. T. I. Ave. Mendoza Comm. BIdq. 2nd Fir. #201 11/27/2006 The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant kuthorized Signature or Stamp Run Initiation Time: 11/27/0616:54:48 Run Code: 1164675288 EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number: 03-135 Page:5 of 19 V CERTIFICATE OF COMPLIANCE ENVA -C PROJECT N 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Flr. #201 DATE1/27/2006 OPAQUE SURFACES # Surface Type Area U -Fac. nsulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Roof 99 0.051 R-19 R-0.0 0 0 New 02-A5 2nd Floor 991 Sq. FL 2 Wall 32C 0.110 R-11 R-0.0 90 90 E)dsti 09-A2 2nd Floor 991 Sq. Ft. 3 Wall 3&r 0.110 R-11 R-0.0 0 90 Blisti 09-A2 2nd Floor 991 Sq. Ft. 4 Wall 262 0.110 R-11 R-0.01 270 90 E)dstin 09-A2 2nd Floor 991 Sq. Ft - 5 Wall 1 65 0.110 R-11 R-0.0 45 90 E)astin 09-A2 2nd Floor 991 Sq. R. 2nd Floor 991 Sq. Ft. 6 Window Front NE 25 0.720 NFRC 0.40 NFRC 45 EAsting Double Mtl Low E 2) 2nd Floor 991 Sq. Ft. N, E, A, R (New, Existing, Altered, I I More than or equal to 10,000 sq.ft of stba-built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default (Yfactors from I I Standards Tnhle 11F.A and R rladffirain shall he filed in the mntraetets nroleet effim duan mnstruetlen and in the huildina manners office after mnshuetion # Type ## Exterior Shade Type Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 1 Window Left E 2 0.720 NFRC 0:40 NFRC 90 E)dstl Double MH Low E(2) 2nd Floor 991 S . . Ft 2 Window Left E 36 0.720 NFRC 0.40 NFRC 90 Double MH Low E(2) 2nd Floor 991 Sq. R. 3 Window Front N 21 0.720 NFRC 0.40 NFRC 0 Ustin Double MU Low E(2) 2nd Floor 991 Sq. Ft. 4 Window Front N 24 0.720 NFRC 0.40 NFRC 0 E)dsbng Double MU Low E(2) 2nd Floor 991 Sq. Ft. 5 Window Right 48 0.720 NFRC 0.40 NFRC 270 E)dstin-q Double Mtl Low E(2) 2nd Floor 991 Sq. Ft. 6 Window Front NE 25 0.720 NFRC 0.40 NFRC 45 EAsting Double Mtl Low E 2) 2nd Floor 991 Sq. Ft. 1) U4'actor Type: 116A Default Table from Standards, Table NI -1 Default Table from me ACM Manual Appendix, NFRC Labeled value. 2) SHGC Type: 1168 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Overhang Left Fin Right Fin Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hgj. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 7.0 3.0 6.0 0.1 6.0 6.0 4 None 0.76 5 None 0.76 6 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,E ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 WIR2. See Section 143(c} H this box Is checked, ENV4C must be filled out. when submitting under the Prescriptive Compliance Approach. I EnergyPro 4.3 by Enerf7VSoft User Number 1268 Job Number. 03-135 Pane:6 of 19 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C PROJECT NAME DATE 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 11/27/2006 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) PORTABLE LIGHTING (From LTG -3-C) LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG4-C) CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED LIGHTING, UNCONDITIONED SPACES (Fran LTG -2-C) LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG3-C) UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED WATTS 775 0 0 775 0 0 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -6-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -6-C) WATTS ❑ TAILORED METHOD (Fran LTG -6-C) ALLOWED LIGHTING POWER F 775 ALTERNATE COMPLIANCE ❑X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (Fran LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5 -Cl 0 MANDATORY DOOR AND DAYUGHTING AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE Check if NOTE TO (Room 1) IDENTIFICATION (Auto Trme Switch, Dimming, etc.) SPACE CONTROLLED Daylighting .FIELD EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number 03135 Page:7 of 19 ERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1 -C PROJECT NAME 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Flr. #201 DATE 11/27/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing I EneravPro 4.3 by EneravSoft User Number 1268 Job Number. 03-135 Pagel of 19 1 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME VAI L 991 So. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 11 uesigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The.NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates and oneratina and maintenance information meet the reou cements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New construction and Rebuilt ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do requite consbttction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required N the unit serves 5 000172 of space or less and 25% or more of the ducts are in noncondiboned or semicondibaned space like an attic. New systems that meet the above requirements. Retrofit systems that meet Me above requirements and either extend duct; replace ducts cr replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls Installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilted and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps we connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flaw chilled and hot water systems that have a design capacity greater than crequal to 500,000 Bfu/Ar. -Water400p Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable f w chilled, hydronic heat pump or condenser water systems where Me pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number. 03-3 135 Page:9 of 19 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME DATE 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 11/27/2006 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description v C C Q °rim fDA 3m c'm Cdr 3w3 gRv 0) N 0 C 3! g px m N o i'm. v0 r C z. 7ZC 3 Cr m y j Li . xdm °'a Yes No (1) 9w Compact Fluorescent Quad 2 Pin sw G23-21 1 9 1.0 13.0 X 11 13 (2) 4 ft Fluorescent T8 Elec 2 3 10 62.0-X— 6 82 40w Wall Mount Incandescent W 1 40 40.0 X 2 80 PAGE TOTAL 775 BUILDING TOTAL (sum of all pages) 775 PORTABLE LIGHTING (From LTG -3-C) CONTROL CREDIT (From LTG -4-C) O ADJUSTED ACTUAL WATTS 775 I EneravPro 4.3 by EnerwSoft User Number. 1268 Job Number. 03-135 Page: 10 of 19 1 s AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C .� (PROJECT NAME DATE L 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 11/27/2006 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method dud sealing requirements. AIR SYSTEMS, Central or Single Zone 991 Sq.ft. Office HVAC System Reference on Plans or Specification I 112(a) 80% AFUE 112(a) 12.0 SEER / 11.2 EER 112(b) n/a 112(c), 115(a) n/a 121(b) Yes 121(b) 149 cfm 121 c No 121(c) No 121(c), 122(e) Program able Switch 122(e) Heating & Cooling Required 122 Auto 122(g) n/a 123 124 R-4.2 144 a & b n/a 144 a & b 51,000 btuh 144 a & b n/a 144 a & b 19,235 btuh 144 c Constant Volume 144 (c) 144 c Yes 144 d No 144 a No Economizer 144 Constant Tem 144 (f) Constant Temp 144 (k) No n WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C IPRaIECTNAME991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 DAT 11/27/2006 YSTEM FEATURES 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, Hydronic Loops ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. if a requirement is not applicable, put -WA- in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 1 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 113 a 113 b 113 c 114 a 114 b 115(c) 115 CHRONOMITE LABS MF - 200C W40VAC n/a n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NIX ins the column. NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 11/27/0616:54:48 Run Code: 1164675288 EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number 03135 Page:12 of 19 MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE 991 Sq Ft T I Ave. Mendoza Comm. Bldg. 2nd Fir. #201 1 11/27/2006 PRESCRIPTIVE REHEAT LIMITATION Section 144(d)) MECHANICAL VENTILATION Section 121 b 2 AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM A D .. 0 a m90 c SIC n T ` °' 3 Z M3 M f o -. Ma O M 7 ' m05 DICT v m 3 O0 IQ 000 ii ,y,G y < to m' M* D7 3 nloo n0 v '. to m C A " cis Ca3m U) n0 _ C - 3- m 0 03: 7 7 - ' D m 0 f D d Floor 991 Sq. Ft. 2nd 99 0.15 149 149 149 991 Sq.ft. Office HVAC System Total 149 149 C Minimum ventilation rate per Section 121, Table 121-A E Based on fbced seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D VA) Is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). I Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area (ft sq.) x 04 dmilt sq.; or L Maximum of Columns H, J, K, or 300 dm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number. 03135 Page: 13 of 19 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME DATE 991 So Ft T I Ave_ Mendoza Comm_ Blda. 2nd Fir. #201 11/27/2006 CHILLER AND TOWER SUMMARY I Efficiency Tons PUMPS System Name System TvDe Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control Split DX 1 51,000 0. '80%AFUE 29,40012.0 SEER/ 11.2 EER Existing No Economizer D BOILER SUMMARY Energy I Standby ANn INJUL. Rated 1 Vol. Condition Factor Loss or Ext System Name System Type Distribution Type Qty Input (Gals.) Status or RE Pilot R Val. HRONOMITE LABS MF- Instant Elec Point of Use 1 31.,400 0 Existi 0.98 n/a n/a r 0- r IAnver n9 CENTRAL SYSTEM RATINGS HEATING COOLING System Name System TvDe Qtv Outout Aux. kW Eff. outout Efficienc Condition Status EconomizerType 8/t%n S E 12.0 SEEER 2- Split DX 1 51,000 0. '80%AFUE 29,40012.0 SEER/ 11.2 EER Existing No Economizer ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME 991 Sa. Ft. T. I. Ave. Mendoza Comm. Bid4. 2nd Fir. #201 IDATE 11/27/2006 DESCRIPTION Designer Enforcement §11 8(.) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X❑ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. RX § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. 0 §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R43 between framing members. EnergyPro By EnergySoft User Number. User Job Number: 03-135 Page: 15 of 19 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 11/27/2006 DESCRIPTION Designer Enforcement F] §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the righting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. F] §131(d)2 Override for Building Lighting Shutoff: The automatic building shutoff system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 6,000 square feel F§119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. F§111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. 0 §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. n§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 260 square feet and that allow for the effective use of daylight in the area shall have 60% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ® §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number. 1268 Job Number. 03135 Page: 16 of 19 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE 991 So. Ft. T. I. Ave. Mendoza Comm. Bldq. 2nd Flr. #201 _11/27/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. a§ 115(a) Fan type central furnaces shall not have a pilot Iight. n§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. FX § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CIVIC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or F] § 122(e)1B An occupancy sensor to control the operating period of the system; or F] § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(aft) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. 0 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. X❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number. User Job Number. 03135 Page: 17 of 19 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM ii PROJECT NAME DATE 991 So. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Fir. #201 1 11/27/2006 Description Designer Enforcement Ventilation r§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 1220 Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 1 0 All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or XJ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on.a continuous basis and displaying that quantity on a readily accessible display divice; or 0 § 121(f)4 Another method approved by the Commission. Service Water Heating Systems §113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. 0 § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number. User Job Number. 03-135 Page: 18 of 19 t s -IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME 991 Sq. Ft. T. I. Ave. Mendoza Comm. Bldg. 2nd Flr. #201 DATE 11/27/2006 SYSTEM NAME 991 S .ft. Office HVAC System FLOOR AREA 991 Outside Air (cfMsgft) 1 0.15 Note: values above IEATING SYSTE 25.0 ° F Outside Air 149 cfm 69.3 OF SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 3,814 32,440 3,94 601 19,963 68.5% R.H. ROOMS 0 1,622 998 0 0 149 5,189 -930 149 6,844 0 0 1,622 998 40.873F 3,0117 28 803 80% AFUE 12.0 SEEER 2-1/2 ton Sys 19,235 9,881 51,000 Total Adjusted System Output 19235 9881 51 000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am at ARI conditions i L_ YCHROMETRICS (Airstream Tel 64.2 OF 101.90F Heating Coil 0. Supply Fan 1270 cfm 101.QOF —� Supply Air Ducts 101.2 OF ROOMS 70.0 OF f% Return Air Ducts `i 12.0/77.9 OF 83.0/71.5OF 68.8/66.6 OF 68.8/66.6 OF - - *- 5 Su I Air Ducts Outside Air 149 cfm 79.2/70.6 OF Cooling Coil 0-- ppY Supply Fan 70.0 / 67.0 OF 1270 cfm 68.5% R.H. ROOMS 6 Return Air Ducts y 78.0/70.2 OF EneravPro 4.3 by ErtergySoft User Number. 1268 Job Number. 03135 Page: 19 of 19 1 T4tv,, W " 78-105 CALLE ESTADO = LA QUINTA, CALIFORNIA 92253 - (619) 564-2246 FAX (619) 564-5617 March 18,,1993 Mr. & Mrs. Peggy Otis P.O. Box 8097 Anaheim, CA 92803 Dear Mr. & Mrs. Otis: The wall at 151-035 Mendoza has been removed the satisfaction of this Department. Thank you for your cooperation on this matter. Sincerely, BUILDING AND SAFETY DEPARTMENT Tom Hartung Director of Building and Safety kt cc: Bonded Rigging MAILING ADDRESS - P.O. BOX 1504 - LA QUINTA, CALIFORNIA 92253 P.O. BOX 1504 TdY4J, No. 10682 Building Address 51$035 MENDOZA LA QUINTA CALIFORNIA 92253 7 Owner .. PETER & PEGGY OTIS ]BUILDING: TYPE CONST. - OCC: GRP. Address P 0 BOX 8097 A.P. Number City ANAHEIM, CAZip Tel. isA—@8*N1F* 192803 1714-099-0553 Legal Description Project Description RESIDENT DEMOLITION Contractor BONDED RIGGING & HEAVY TRANSPORT Address P 0 BOK 1774 CityZip RANCHO &IRA fi 92270 Tel.: 325-5523 State Lic. City & Classif. A, C-21, HAZ ASB Lic. # Sq. Ft. No. No. Dw. , Size Stories Units Arch., Engr., • Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and _reffect. t SIGNATURE " DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a Permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) Estimated Valuation Q 1 4 Y 3 PERMIT AMOUNT Dep. Plan Chk. Bal. COf1St. $pQ Mech. Electrical Plumbing ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. B. 8 P.C. for this reason S.M.I. Grading Driveway Enc. Date Owner Infrastructure Demolition $30.00 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company Copy is filed with the city. O Certified copy is hereby furnished. TOTAL 3 a CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the perm/t is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. REMARKS i 3.L1 f;+i.: j-3 ;: i U j AL 1 Date Owner NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name FINAL DATE Side Street Setback from Center Line Side Setback from Property Line INSPECTOR Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives .of this city to enter the above-. mentioned property for inspection purposes. Issued by: Validated by: Date Permit Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES .r 1ST FL. SO. FT. ® $ 2ND FL. SO. FT. POR. SO. FT. ® GAR. SO. FT, ® CAR P. Q. FT. WALL SO. FT. ® SO FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation BONDING FLOOR DRAIN MECHANICAL FEES FORMS WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPIEOUIP. LAUNDRYTRAY AIR HANDLING UNIT CFM TEMP POLE KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ®c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1 Vi c SEWAGE DISPOSAL SO.FT.GAR ® VVac HOUSE SEWER VENTILATION GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPIEOUIP. REINF. STEEL GAS (FINAL) TEMP POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL GRADING cu. yd. $ plus x$ =$ LUMBER GR. FRAMING FINAL INSP. ROOFING / GJ REMARKS: VENTILATION FIRE ZONE ROOFING: FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION '• CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL Sgp")v y,COagt -ty• , Mai gz:mrnt l3 ict M,.+MrblSrv.r " "r AS'BZSTOS DEMOLITION/RENOVATION NOTIFICATION rROJECI' JCB #&o4 __- ___-- i)Cancellation Revision (Protect Dates) Revision (ocher) For Cancrllattoo or Revision, 1`111 out scttons 1403(d)(1)(A)(1), (if), 0v) avid others that apply. ` Notif: Completed By:_.t-.._Date: ppl) c1,- i c, a Date Rec: Company:3onded Ripg i.tlp Telephone: ( 619) 325 55_2,3 YAit, TO: POSTMARK: South Coast Air Quality Management bitvtrict Status Code: Hazardous Materials Section/Enforcement 9150 Flair Drive Quarter: El Monte$ CA 91731 Entered By: SCAQXD—t1SE-0NLY— } 1403(d)(1)(A) 1,'M Vr'ItTI'I N ONLY$ Incomplete No !lcadou will irtsutt to Enforcement Action. 1 , d):(i)(,A)(i) olzeretor/Coatruetpr. (For a Demolition Job, please fist Demolition & Renovation Conttiaors.) Name:Bonded Rigging, & Heavy Transport Address: p 0 Box 1 774 City, State Zip -code: Hancho Mirage, Ca 92270 _... -` Site Supervising Person: Edward Gonzales ` r hone: Fele . P (619) 346 1.307 _ 1.403(dl(1)(A)(t) Property Owuer(s). Name: Peter T. and Peggy Otis Address: 1301 Arroyo Lindo Drive City, S tate Zip -code: Santa Ana, Ca* 92705 Contact Person: p e p s y Otis Telephone: ( 714) 731-6204 i :i'(d?(;l)(,4) (11) Facility location. (Please we tadee whets indicated) Site dame: Street Address: 51-035 Calle rdendoza City, State ZiCode: La Quinta, Ca 92253 ' ountr. Riverside i DeI17ol1tI0i3 f e ition: D ,)emolltioo , em&M Qrdesrd Demolition me y Renovation Y443(d}(1)(A,}(iii) FvzctltlY IDebc luoi , Rkact we code: where indicated) x' Size (Sq. F°t: :-1600 s f t y `1 Age cars : 1950 Number of Floors: 1 Building e : R L mmeroial HospiW Industrial Dirks ,!ubtic Building Raidem 'Behovl Prior Use , iz LommeKW 1Joq9W Jnduarw QKtce Vuelis Euiwltta 2rsidcna School Number of Dwelila Units:- ' `i` f 3 (For Rssidartcs Only) - r Work Location (Described: `Throughout 1403(d)(:)(A)(ty) Project Dates. Start Date: 2130/ 92 Completion mate: 3/05/92 SCAQMD Rule 1403 Notification Form (1403.FM Page i of 2 P1ROJECr JOB 1403(d)(1)(A)(v)1r41ratt Worts Practices ao�,� s�lateeNltg Cowro!s., oteftmoce IM3(d)(1)(0)(1) tbrottgh (v), Z?CeQiilYC: jet / A c,,w (1odicste 1, 2, a, 4, or S. Vic multiple it applicable. 4 & S Require Astochmenu.) '140(d)(1)(A)(4) Amount of Friable, Class 1, and Glass It nontriable Asbestos Containing Material (ACM). Friable Lip -ear Feet: tit/A Square Feta: Class I Unear Feet: Square Feet: 1Y 3.14 d - (Dtotnescr or Pipe and ACM in Feet) Unear Ft. Equivaient (Sq.Ft.) . (TI )(d)(Unear Ft.) Surface A eQ Equivalent.- N / A (fb'IA►L o(Unear Feet Equivalent and Square Feet (Friable and Clue i)) Class );i. Linear Peet: Square meet: N / A Surface Ana Egalvalent: NIA CrOTAL of Linear Fest Equiv%knt and Square Feet (Ctau 11)) Dexcil-ile Friable: Clcss I. N / A Citts9 If: i4&Rd,)(0(A)(vi1) Waste Disposal Site. Landfill wine: N/A Address: City, State Zlp•code: Permit #: Promdurtl to be followtd it unexpected asbestos is found or tnontriable ACM becomes triable. N/A 1403(d)(1)(A)(lx). Pmf or California State ConttractorCertitltntlou and Cal/OSHA Registration. Contractors Ucexsse #: 529442-A, C- 21, H a z, A s b 000SHA Registration #: 1403(d)(1)(A)(x) Lomdoz of otr-site storage arca forrasbestos containing waste mrterial. Iti / A 14M(d)(1)(A)(A) Name ottmatporttr(s) used to transport waste to disposal slta.. N/A Emergency R,tnovv>tatlon. ` Autlno>; ized. Person: N / A Telephone: 11103(d)(1)(B)(0) Energeocy (Ordered) Demolition. (! %o ordered the demolition?) Agency: Name: N / A Title: Telephone-. Authority: SCAQMD Rule 1403 Notification Form (1403.FRM) Page 2 of 2 '11 till•; , �}a• + AMS HATEC 03i1Ci42 17tela is i�19 369 3146. t s }SAMLES- ANALYSIS REPORTK Report ootot 4$/03/9! %mq! jo0 lot 1 00759C01 CUst9tixrI pomonP volley Cqui.pwnt Rontel ine. kenc it�om g i'300 Pornohe Blvd -CA' of�6a intpootlert Oeter 0;/04/Oi lna ctort Not Applicable 0 dob kantOi Vacant Rtsldence Pepe Nu*ert 1 Job+N"umbers NONE b10S5 Avd Handalo La 6uints, cA opo..cre♦aprrCCCeeeet ►6tneYfsePP.df-L•S.EV4R�calCCLtCcecauYlE.vecCei7VLPf P►r.aeOCN Pa.ebntrlCprbpue�saPpep PfatlaPP9PPf,1sM:allia6l6lOpOq semis a�bcrr 1 z 3 sAMP@ o�t:cttintt611 ago lOGaitON 1pWago Cabo oto ut>)retOry WLpbor: $6509 36510 36511 �651Y l b9�,Astoa i+rsooi�t l N N A � L" Ac�estas tvr�6 0 0 0 'ntNoilr. fiborts AW hpHCR,ktAUS 0 0 yermlculitot 0 ,r attlICP1/Y VPf��a9t ti+ry00ti10) 00 06 OQ 00 e�silot. 00 00 00 00 x CrpCidOtjtai 00 00 00 Go C61tIt®: tre�tltol 00 00 00 00 x Aatlaolttet 00 00 Oo 00 I Ant hc'fhy'tlitoI 00, oo•y 00 00 ,� t1ll,1fiKlAlSt �►vf:►tpt9¢Otrlu• tlev� 4+col; 0 0 D 0 k�in4reie! K n x x ilbroua COW 0 0 0 0 'ntNoilr. fiborts 0 0 0 0 yermlculitot 0 0 10 0 coituloiol K Y, x x WPod1 0 0 0 0 C61tIt®: a 0 n 0 84-mler/0 (tort x 0 0 0 sPruter gatcrfelr 0 0 0 Q for: 0 0, n 0 eAcr motbfia; it 0 khat m4teriII 21 0 a 0 0 G het istsritt. for sirr*le .2t Paint tffid of, 1 Nett Dlavtor Wroom 01 2 stall Kloster bedroom 0 3 Welt 1`49ttr bedroom N3 4 Collin* Paster Living Ago) FROM POMO 714 5912303 03/12/92 11:46 P. 7 TOTAL P. 7 •tiY6�1��i�w,.o+sid�oM.'Mi9i)h .r..+M" es/is/92 l6t59 2t 81t 364 5:66 AMS HATEC �-j 4e„ los 1100 0001 �,etr+�ct 'veno lnorrrme (iftt(,Aqtepr ftt ,tlCeb4 # rW*tow , e Job HtrW f "K •per �. 6 •� E.NvIRONMENTAL SERVICES. INC BULK SAMPLEs ANALYSIS REPORT CuOlo"r: PO(mno Vollry EgUIOM,lt Rental Inc. mo Do"Ma s, 6. Poponj, CA 91768 w,L Nehlol 46Cant Resida',­ 51035 AVO Mendora ^A Report bates oslosiol! Anoyell batsr 0310SM Intpittlon baht 03MI92 tov6r llttOr ' (.0 OUintO •.illlillltiMN.f.'.l'JP,lYw4b. �RR QRRsaM.[flf1►►tY.6lN9iA>16.L'Ctl.�•►r![titi/f i f6OC��Y�cr/.f \Yrfil. BltiwY.f,l9►/�ar M W!!!!M! i! r•slff etflf ff ff Four samples were colleoted from the above referenced ef erencedthe iJob�ale+ of The anal s;iss of samples i p t7hl �ri ed ligh microscopy and d (_d in On t}legeationell v lunta.�yn?Laboraitory M" thods and proosdurea deta ed i n Ina. °editetion pro rap under which AMS-NRTEC Environments ltSerVi.agAs m�ie,vInc J# *oordi.ted. ggnte should ry�t c2 that carr ary timated p e on a tial,ly between oPwtheaeama"gampleti.g the®samerlNb,&n �rcer�tad even eseie>ars V�Q>>aowaasalV4 t tded to the nearest whole percent • TnaFormseam lej}r®sul tlt�tha►t erAhrt ltd the symbol eyoyy mesas, "gloater than". For is quanMied using point #e rr ed as 10 or ]ass, described �c�_ << t;ng prooeduYB>a as QQscr i ted it) 40 cox 163, stibQrlrt i4 , Appendix A. Sayoples were tested as submitted by Cl;ent unless inRPOOti.on and ea►mp" i•ng ,'by AMS is epaaifted. The report epplins r -)ply to the samplt3e IeF: t;ed. It may not gov*rnmental Bsd to bUncy. aItrrr.aalnot; beaendorsement reproduc retho produced ospt laboratory or. any g in full and with wxitt� e�eto`is� zoQucefrom upthe to fiveaCop%% ofithesreport hereby exppreesl perm rr�cords of school inspeo- for prinoipal>;a in real estate trangarct ions, tion and tenting or for their. for their clients) reriord�• These tests were pgrWdrt�gd;nert!:llygac-ceptedQtegtnn tho laboratorywprinai- parsd in aocordlance i g ' pals and practices. This warranty ig in lieu of a 1 other t�alrrentioa expresteed or implied. nee1v:e11 sv'_ .. - vvt, , thomar F ROM Per 0 7 1 4 5S 1.: � : 3 L, Z) Q: ,C_ , , : .I Z) �- . o �IiAN rr A kaoi . CAY (R1AI.160-5166 AT YOUR SERVICE i CLIENT: PROJECT: i I I I DATE: AMU T: 1 , I C and'H LABORATORY TEL No.714-991-1742 Feb 20,92 12:43 No 005 P.02 BONDED RIGGING & HEAVY TEL:1-6197325-5523 Feb 17 92 5:12 No.001 P.02 l South coast Air gement District ASBESTOS Dk;MOLITION RENOVATI / ON NOTIFICATION PROJECT JCB : [ j Cancellation [ J Revisiou *(Project Date&) ' [ Revision (other) For cuasllifi6if Mi fill out sections 1403(d)(1)(A)(i), (ti), 00 and others that apply. completed RX: Date: Companyt ! - Telephone: MAIL TO: South Coast Air Quality Kahal6latht bistiriot Hazardous Materials seotion/Entoreament „,. 9150 Flair Drive ElkMohte; CA 91731 Motif 0: Date Root POSZ''MARK status Codes Quarters Entered Sy: s 4AQXD-USE-0NLY- 14030)(1)(A) e`'I' LNVRITTEN ONLY# Incomplete Noti!teation will result in Enrorrement Action. 1403(d)(1)(A)(1) Operator/Contractor. (For a Mmotition )ob, pmw list DefnolitioA /t;tenovrttor, Canttaetont,) Name: Address: City, State Zip -Code: Site Supervising Person: 'Telephone; 1403(d)(1)(A)(0 Property owver(s). Name: Pa+ r r T, 01, is 4-. ?eS'9 Y O f ).$ Address: t 3o 1 A i- rc,y c h► 1.-i j o b r - y G�ty, State Zip -coda: -6"+a. .Ana , " Ca, , q A 70 s x Contact Person: ?e yejy 0+15 Telephone: 714 � 731,420q (N) 7�'� - 99'92'�05-53• lw ) 1403(d)(1)(A)(ll) iRAcility Location. (Plus vie *as whets indlated) X Site Name: X Street Address: 5 1- o 35 Cc► Ifs }'1e,►c:�az�:. 19 City, State Zip -code: L eL Qu i of R, Co- . 0.7. 2 s 3 County: ?.i Vert; id e Demolition/Renovation: DCM114on &mwW - Q146,od Denlwition E+ n,,c"roq 1e00 -611M. 1403(d)(1)(A)011) Facility Description. MOM the cow Aisne tnalpttw) Size (S Ft Age ears: Number o doors. Bufidixt$ T !! :ann�erciat jliospltatr ;�nau.�ri.t-��rGse=i+biae B�iliaj�r'ce chow .Y _ Nor" V.P� : k•�.`.e - ofkln67R�it "j�p�l:fi �D4ULttisi�'�OtltlC 011iid{O� t� ppC ^OOt "v.:t� Nuntbir of Dv ilUn& LlWts: (F" �"' ' Work Lo Iani4enee only) � ,. Location (Describe). _ 140�(d)(1)(A)(ih 1�roject Aotea, . Start Date: Completion Date: • • SCAQMD Rule 1403 Notification Form (1803.1F'R1►� Par I ort . Imo• - - 11 .. C andH LABORATORY TEL No.714-991'-1742 Feb 20,92 12:43 No.005 P.01 S ENTEJKPRISES. P.O. sox 3099 ANAMEt". CAIMPORNLA 92603 714 999.0883 a FAX COVER SREET TOi�Qn�c�� cd FROM NUMBER OF PAGES (.including this one): COMMENTS: -� a If you do not'reaeive'all pages, or you have any, questions, please feel free to call (714) 999-0553. THANK YOU. C' and H LABORATORY TEL No.714-991-1742 Feb 20,92 12:41 No.005 P.01 T & S ENTERPRISES P.O. BOX 8007 ANAHEIM. CAIXFORNIA 92803 714 099A859 j FAX COVER SHEET TO y l I FROM NUMBER OF PAGES (including this one): COMMENTS: l if you do not receive all pages, or you have any questions, please feet free to call (714) 9990553. THANK YOU. 4'w - LH-7 -�� . TEL 'du .,1-;-99? -i-4? Orlando Gonvales Bonded Rigging! P.O. Box 1774 Rancho Mirage, CA 92270 N . S ENTERPRISE -8 .ny Y.A nox 6697 ANAIiL* M, OALMORMA ORM4 713 90"Kh8 march 16, 1992 Har 1u,92 1-:59 No.001 P.01 Re: House located at 51-035 Avenida Mendoza in the City of Iia Quinta Dear :,,3r. Gonza)es: This le..t,ter is to acknowledge receipt, of n negative Asbestos report from► Environmental Services, Trac, on the Kbove mentioned property and are hereby authorizing you to proceed with demolition of said property as per our agreement. Shots -Id further information or assistance be nece%sar•y, Nl��rise feel free to contact. me. Sincerely yours, Per y Otis_��. OWIIO T' bf 4 4,Q�w P.O. BOX 1504 Building 78-105 CALLE ESTADO Address 51-035 Mendoza LA QUINTA, CALIFORNIA 92253 Owner Mailing Address P. 0. BaX 868 CityZip Tel. Quinta :2253 564-1153 Contractor Aaaress ._ N0. 003747 BUILDING: TYPE CONST.—OCC.- GRP. - A.P. Number 773-075-006 Legal Description Project Description New tank and pit P. 0. BOX 868 City' - Quinta Zip 1' - 92253 Tel. $64--115€ State Lic. & Classif. 368149 City Lic. # 1052 Sq. Ft. No. No. Dw. Size • Stories- Units Arch:; Engr., — -' ' Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City Zip State Lic. # ~ LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9'(commencing with Section - 7000) of Division 3 of the Business and -Professions Code, and my.license is in full force and effect. . . —I . SIGN_ A_TURE DATE " OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.S,Business and Professions Code: Any city or county which requires a permit to construct,` atter, improve, demolish, or repair .:any structure, prior to -its issuance also requires the applicant for such permit to file a signed. statement that he is licensed pursuant. to the provisions o/ the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation o/ Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): . -' ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner o/ property who. builds or improves thereon and who does such work himself or through his own employees, . provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) . - . , ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Seca 7044, Business and Professions Code: The Contractor's License Law ' does not apply to an owner of property who builds or improves. thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O I am exempt. under Sec. B. 8 P.C. for this reason EStlmatcd Valuation i+ �� $ - AMOUNT PERMIT -' Plan Chk. Dep. •- Plan Chk. Bal. Const. ' Mech. . Electrical Plumbing - $40.00 S. M. 1. Grading Driveway Enc. Date owner Infrastructure WORKERS' COMPENSATION DECLARATION Thereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city.. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed i/ the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation ' Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) - Lender's Name Lender's Address f This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. 1 certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip HARD COPY TOTAL REMARKS ZONE: • BY: Minimum Setback Distances: Front Setback from Center.Line Rear Setback from Rear Prop. Line Side Street Setback from -Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued:by: Date 3/25/8$13ermit Validated by: Validation;_ CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ 2ND FL. SO. FT. ® POR. SO. FT. ® GAR. SQ. FT. ® CAR P. SQ. FT. WALL SO. FT. ® SQ. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET — YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation BONDING ROUGH WIRING FLOOR DRAIN MECHANICAL FEES DUCT WORK WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER OTHER APPJEOUIP. GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED TEMP. POLE LAUNDRYTRAY AIR HANDLING UNIT CFM GROUT KITCHEN SINK ABSORPTION SYSTEM. B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE; TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SQ. FT. ® c BATH TUB ROOFING SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL VENTILATION SQ.FT.GAR ® 3/ac HOUSE SEWER FIRE ZONE ROOFING GAS PIPING PERMIT FEE FIREPLACE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE FORMS ROUGH PLUMB. Al SEWER OR SE TIC TA BONDING ROUGH WIRING HEATING (ROUGH) STORAGE TANK DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ _$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL