SFD (0206-110)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date �}
634.981 B 1/11ff
Date/ �` ', r ? Signature of Contractor\^� -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors, to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty ,of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:.
Carrier STATZ FC3?�U Policy No. 154201-Ol
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the. performance of the work for which this permit is issued,
I shall not employ.any person in any manner so as to become subject to the
workers' compensation laws of,California, and agree thai if'l should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with%those provisions.
Date: f Applicant ^
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth onr his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property fogy inspection purposes. t �i
Signature (Owner/Agent) ADate/
ti
PERMIT#
BUILDING PERMIT 11110
02065.110
Q
DATE VALUATION 89'X¢.,m'o LOT 21 TRACT BLK I IJOB
SITE
ADDRESSBl^CY`C11,, iTSS iY 6•l�kf d.I�t �,�
APN
OWNER
CONTRACTOR/DESIGNER/EN &NEER
COR010m,
COk014EL C-01415T%dT=014
POBOX
3r�*89
78.15-7 �C�.N1I.1%"wt'MV. FICIO I 6idSi;Na=)
yyQo-�X
LA QV.t1♦A 07A 9225.3
LAQUINTAi. CA 922y3r _
(76g)W-4604 CBLO 2,."61
USE OF PERMIT
�1Tf�'�.t.,;L*'•��illtxf `i` Si�"I�%•�.�YC�'
SFIJ - LOT 2I • SA PJ'A qE ASTER, PERMIT .` CIES NOT.INCLUDE
P004 SPA OR DRWKWA'ti•APPROACH
'1`UC T CONSTRUCTION OF
PORCH/PATIO sr
G ARAOUCARnORT &ISt,r10 OF
K FT. WOOD I°M1.ErNICI✓ 200,00 LY
E.71MAXY. PT) coyr OF 110I URRAXWL+P!:x
ZY,ayf+a�' 7n10
CO n RUC TION F'XE 101-000-418.000 $594,50
PLAN CH.WK PEP, 101-000-439-318 WO -,12
PET DF -POSIT 101 -WO -439-318 •S.2.01011
MECHANICAL PEE 101-000-421-00I $50.00
ELECTRIC&L 11W 101.OW420x000 $WA
PLE,MI M70N'im. 201-000.419-000 3I;0.73
aTRONO MOTION F'EF. - RUID' 101.000.24 -t -CM
t3:RA:t-s3'NO FEE 103 -00Ci �i23-CItIi3 $xsa.V t? ,
DWELf'iPE11.IMPACT FEE
I`RPfiI L I�Y.r�t( 101-.00 D-44.1.345 6,C1ii,fff2
,w
8UB-T0TAtX0), CTRUC1iCY AND PLAN CHE ''K
S3,923.74
3 PR&PAM. s
il-V..3U.00
- �a
DFJUN
kn4J']t�.7dl:.L�hS.d1'a6CA�S401aPS 7.�iJ ^E;NOW
We3676,74
i 2001 ,
WY OF LAQUiNTA 4
FINMCEDEPT.
RECEIPT DATE
a
DA FI D
INS/PETOR
INSPECTION RECORD
-- OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap ? Z.p
F.A.U.
Framing . y ,v Z
Compressor
Insulation .p Z
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath . pAt
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection �� , 0-1—
Encapsulation
Gas Piping
Gas Test aZi2� O Z
Appliances
Final
Final
Utility Notice (Gas) "
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power, p 2
Final
Utility Notice (Perm)
COMMENTS:
4
P.O. BOX 1504
Building_ . CALLTAMPIO
Address LA QUINTA, CALIFORNIA
92253
Owner ,- 1
Mailing
Address
City Zip Tel.
J.f��h
COactor
nO - J r. t\ C-1, __Sl
Address
City Zipq Tel
State Lic. City
& Classif. L3�AC1001 9c)
" Lic. #
Arch., Engr.,
Designer
Address Tel.
City — IZip IStae
LictIII
LICENSED CONTRACTO S DECLARATION
I ere ffirm that 1 am licensed under p vi ons of Chapter 9 (commencing\ lith Section
effec vislorr3lof the Busiadk3�ap d Pr es ons Code, and my license Is In ( rc�d
�WemptBUILDER DECLARATION
1 hereby eflir that I exempt from the Contractor's License Law for the following
reason: (Sec. 703 .S,Bus ass and Professions Code: Any city or county which requires e
permit to construct, Ite Improve, demolish, or repair any structure, prior to its Issuance also
requires the applicant or such permit to file a signed statement that he Is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code. or that. he Is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penally of not more than five hundred dollars (8500).
U1 I, as owner of the, property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. 11, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or Improve for the purpose of sale.)
1 1 I, as owner of the properly, am exclusively contracting with Ilcensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
I l I am exempt under Sec. B. & P.C. for this reason
Dale Owner
WORKERS' COMPENSATION DECLARATION
I herebyaffirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No.Company
(7 Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed If the permit Is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of lhp work. for which this permit is Issued, 1 shall not
employ any ppeon In any manner so as to become subject to the Workers' Compensation
Laws of Call fornirsa.
Date_ Owner
NOTICE TO APPLICANT., It, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I -have read this application and state that the above Information Is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-
mentioned property for inspection purposes.
Signature of aOplicant Date
Mailing Address
City, State, Zlp
\`0
APPLICATION ONLY
a°
LDING: TYPE'CONST. OCC. GRP.
�''7-7
. Number 1 1 "\SD —0 C3J o� _
al Description\1 \off . aN \. l
T
ject Description's- V: -
Sq. Ft. No. 1 No. Dw.
Size 1��� Stories Units
New ID Add O Alter ❑ Repair 0 Demolition 0
1
Estimated Valuation
PERMIT AMOUNT
4-3
Plan Chk. Dep. 2 SO
Plan Chk. Bal.
Const.
Mech. _
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS _
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
INSPECTOR
Issued by: Date Permit
Validated by:
' Validation:
WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION
Desert Sands Unified School District
47-950 Dune Palms Road
Notice: La Quinta, CA 92253
Document Cannot Be Duplicated 760-771-8515
Date 6/18/02
No. 23308
CERTIFICATE OF COMPLIANCE
APN #
Jurisdiction La Quinta
owner NameCoronel Enterprises
No. 51840
city La Quinta
Street Avenida Mendoza
zip 92253
� �y�FlEbsc�O
BERMUDA OUNES
N RANCHO MIRAGE
Y INDIAN WELLS b
d� PALM DESERT
LA QUINTA
Q INDIO .y�.
773-182-004
Permit # 0206-110
Log #
Study Area
Tract # BLK 119 Lot # 21 Square Footage 1421
Type of Development Single Family Residence
Comments
No. of Units 1
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It
has been determined the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of
2.14 X 1,421 or $ 3,040.94 the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued
Fees Paid By CC VIB - Ish Coronel
Name on the check
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Crystal Scott Payment Received
Check No.
Signature
Telephone 760/564-4604
,ter
$3,;040.94
267183
VOTICE: Pursuant to Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified
above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to
:ollect them on the District('s)(s') behalf, whichever is earlier.
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
Certificate o*f
Occupancy
City of La Quinta
Building and Safety Department
This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code,
certifying that, at the time of issuance, this structure was in compliance with the various ordinances
of the City regulating building construction or use. For the following:
BUILDING ADDRESS: 51-840 AVENIDA MENDOZA
Use Classification: SFD Bldg. Permit No.: 0206-110
Occupancy Group: R3 Type of Construction: VN
Land Use Zone: RC
Owner of Building: CORONEL ENTERPRISES . Address: 78-150 CALLE TAMPICO SUITE#230
City: LA QUINTA CA 92253
By: KIRK KIRKLAND
Date: 08-28-02
LIBERTY.v4v
ESCROW INC.
901 E. Tehqultz Canyon Way, Sults A-101
Palm Springs, CA 82282
(760) 322-2060 FAX; (760) 322.2167
MASTER FINAL SETTLEMENT STATEMENT
SELLER: Kurt Boohner, Trusteo of of the Women's Medical Group
of the Desert, Ino., POnalon Plan and Trust
BUYER: Michelle R. Elohstedt II��
Property Address: vacant lot - APN 773-182-004,
BELLER
DEDZT'S CRapITS
CON9IDEXATXON
$ S 60,000.00 Total Conaideration
aaah Deposit
Cash Deposit
Cash Deposit
1,000.00 Pre-release per
instructions
5,000,00 Pre-release per
inetructions
34,085,95
40,065.95
CLOSING DATE:
April 12, 2002
ESCROW NO.; 08362 -MS
BUYER
DEBITS CREDITS
$ 40,000.00 $
1,000.00
6,000.00
35,461.00
PRORATIONS AND AD.7USTM'ENT9
85.95 Taxes at 195.69/6
85.95
mo. from 06/12/02 to
07/01/02
ESCROW TO LIBERTY
35CROW, INC.
Escrow Pee
660.00
Drawing Grant Deed
68.00
Drawing Quitclaim
66.00
Deed
TITLX TO ORANGE
COAST TITLE COMPANY
OWnez6 Title Policy 395,00
Fee
RECORDING CHARGES TO
ORANGE COAST TITLE
COMPANY
Recording Grant Dee4 27.00
Recording Quitolainl 30.00
Deed
TAX CHARGES TO
ORANGE COAST TITLE
COMPANY
Documentary Tranpfer 66.00
Tax
NE¢' PROC3=3
R9PVND 89.06
40,085-95 .TOTALS
41,461.00 41,461,00
RC DISTRICT - PLANNING REVIEW FORM
This form is to be used by CDD staff for review of single family dwellings in the RC (Cove
Residential) District per Section 9.50.090 of the Zoning Code. Its purpose is to determine:
1) that the proposed house design does not duplicate the same architectural style of any
house within 200 feet of the applicant, and/or 2) if there is a need for the applicant to file for
Master Design Guidelines. If the applicant does need to file a Master Design Guideline, please
transmitted this information to the Building and Safety Department as part of your correction
list. Please attach additional explanations as necessary.
APPLICANT Coronel Construction
SITE ADDRESS 51-840 Avenida Mendoza
APN 773
- 182
- 004
CASE NO.:
2.002-656
LEGAL:.
LOT
21
BLOCK
119 UNIT Z S.C.@V.L.Q.
CHECK AND APPROVED BY: Wally Nesbit
DATE:
Inform the assigned Building plan checker upon your assignment to this case. The CDD
Executive Secretary maintains a log book to track applications and assign case numbers.
REQUIRED ITEM
Y
N
COMMENT/CORRECTION
Verify legal and APN informations
i"t fry o
Consistent with MDG on file las
applicable
N(�
MDG filing required (5 filings since
9/3/98)
J
N(�
Architectural variety within 200 feet of
the surrounding area:
Colors
Materials
Architectural design features
Approved bX;
Other Requirements: E3 Planning Com
O City Council
Community De
Initials
Case No. a
Exhibit
ilsslan
i. De
-
20o
------
----
Y
AUG -24-2002 06:56 AM
P.03
INSTALLATION CERTIFICATF r,U cn
DUCT LEAKAGE AND DESIGN DIAGNOSTICS
QUCT_LEAKAGE REDUCTION
N:�•s�urtz:,�tnn'fcst Results (CFM @ 25 PA)
'fest Leakage (CFM)
Flo
is C'-1Irulated as 400 cfndton x number of tons, or as 21.7 x Heating Capacity
�7
in Thousands of Btu/tu, enter calculated value hereLJ
u�
If fan flow is measured, enter measured value here
Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) =
Pass if leakage fraction 5 0.06—
❑
❑ For AEROSOL 'TYPE SEALANTS ONLY - The following diagnostic testing was
Pass Fail
completed:
Duct Fan Pressurization at rough -in measured leakage (CFM)
CHECK AFTER FINISHING WALL;
❑ Y'rs ❑ No ❑ Pressure pan test or House pressurization test
❑ Yes ❑ No 0 Visual Inspection of Duct Connections
❑ ❑
Pass Fail
''THERMOSTATIC EXPANSION VALVE (TXV)
VLJ �'es ❑ No Thermostatic Expansion Valve (or Commission approved
equivalent) is installed and Access is provided for inspection
❑
Yes is a pass
Pass Fail
CI DUCT DESIGN
❑ Yes ❑ No ACOA Manual D Design calculations have been completed,
Duct Design is on the plans and duct installation matches
plans.
❑
-' TXV is installed or Fan flow has been verified. If no TXV,
Yes ❑ No
�
verified fan flow matches design from CF - IR.
Measured Fan Flow =
Yes for both 1 and 2 is a Pass
Pass Fail
P I. the under5i6mcd, verify that the above diagnostic test results and the work I performed associated with the iesr(s) is in
i onfurmante with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the C'F•6R
il�.Wekl by :he builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for
compliance credit.)
., <:'O
I'crfurrneci d' .,17arure, Date v Installing Subcontractor (Co. Name) OR
General Contractor (Co. Name)
Building Department
HERS Provider (if applicable)
Bu.i;ding Owner at Occupancy
TITLE 24 REPORT
Title 24 Report for:
Plan Standard Santa Fe
Gas Furnace/Elec Condenser - HVAC
La Quinta, Ca. 92253
Project Designer:
Coronel Construction
P. 0. Box 389
La Quinta, Ca. 92253
760-564-3604
Report Prepared By:
Jack LaFontaine
Energy Management Service
41- 485 Adams Street, Unit C
Bermuda Dunes, CA 92201
760-360-4631
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
Job Number: APPROVED
9/30/01
' FOR CONSTRUCTION
{
DATE �3 OL. By 5-7
- Date: - o
9/30/2001
n The EnergyPro computer program -has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnerovPro 3.1 By EnergySoft
Job Number. 9/30/01 User Number. 5021
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Plan Standard Santa Fe 9/30/2001
Date
Project Title
Gas Furnace/Elec Condenser - HVAC La Quinta =Permit#Project AddressEnergy Management Service 760-360-4631 Documentation Author Telephone
15
Computer Performance enc Enforcement A Use Only
Compliance Method (Package or Computer) Climate Zone Agency y
GENERAL INFORMATION
Total Conditioned Floor Area: 1,421 ftp
Total Conditioned Slab Area: 1,421 ft2
Average Ceiling Height: 9.0 ft
Building Type:
(check one or more)
® Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Ebsting Building
❑ Multi -Family ❑ E)osting Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories:
1 Raised Floor
Component
Const.
Frame Assembly Location/Comments
TVDe U -Value (attic, garage, typical, etc.)
R-30 Roof (R 30 2x12 16) Wood 0.034 Exterior Roof
Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation
Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation
R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall
Solid Wood Door None 0.387 Exterior Door
Fenestration
0.40
0.40
0.40
0.40
Exterior
Shading
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Overhang Side Fins
Yes / No Yes / No
❑
0
FENESTRATION
x❑
El
Type Orientation
Area
(SF)
U -Factor
Front
25.0
0.65
Left
25.7
0.65
Rear
60.0
0.65
Right
39.0
0.65
Fenestration
0.40
0.40
0.40
0.40
Exterior
Shading
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Overhang Side Fins
Yes / No Yes / No
❑
0
❑
x❑
El
11
191
❑
0
❑
FRI
El
El
El
EJ
El
F1
F1
❑
❑
❑
❑
El
El
Q
El
❑❑
El
El
❑❑
El
1-1
F1
F1
El
El
F1
El
El
0
of
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Plan Standard Santa Fe Date 9/30/2001
Project Title
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution .
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Cpntral Furnace 80%AFUE Ducts in Attic - - 42 Sethack over Suctem
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value
Thermostat Location /
Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 4-2
Sethack HVAC' Sustem
WATER HEATING SYSTEMS Rated 1
Tank Energy Fact 1 External
Water Heater Water Heater Distribution # in Input
Btu/hr
Cap. or Recovery Standby Tank Insul.
(gal) Efficiency Loss (a/a) R -Value
System Name Type Type Syst.
A C) S 1jb ES_G-4n-222 Small Gas Standard 32.000
_ 40_ 0-5F n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input,
Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design Ire spo ' ility. When this cgrtifi a of complia Ls submitted for a single building plan to be built in multiple orientations, any
shading featuiP.
is v ied is indicated in a Special Features/R rks section.
Designercaner (per si es Professions Code) Documentation Author
Name: Name: Jack LaFontaine
Title/Firm:oner C str on Title/Firm: Ener Mana ent Service
Address:. Bo 38s Address: 41 485 Ados treet Unit C
-- ----
Tel ne: Asa564-s6oa T
c. #:
(signature)
Enforcem n ency
Name:
Title/Firm:
Address:
Telephone:
EneravPro 3.1 By EnefgySo
User Number: 5021
(date)
Job Number: 9/30/01
o -C,1
(date)
of 14
Certificate of Compliance: Residential
ndum) CF -1 R
Plan Standard Santa Fe 9/30/2001
Date
Project Title
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
t b ''din or design that otherwise complies
enforcement agency determines the adequacy of the justification, and may ruse a w g
based on the adequacy of the special justification and documentation submitted. Plan
Field
The DHW System "A.O.Smdh FSG -40-222" Energy Factor = 0.560. An EF below 0.58 requires an R-12 Extemal Blanket.
The HVAC System "HVAC Sustem" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 965 sgft Covered Slab Floor, 3.50" thick at Mechanical - One Zone
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 456 sqft Exposed Slab Floor, 3.50" thick at Mechanical - One Zone
The HVAC System "HVAC Sustem" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC Sustem" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
HERS Required Verification
—ne _4-.-A- •hu--micinn of a CEC approved HERS
These features must be confirmed anp/or tested oy d cxnnnsu n- .aac. w....v. ... ..r-. -'- -
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R.
Plan
Field
The HVAC System "HVAC Sustem" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC Sustem" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
3.1 By EnergySoft User Number: 5021 Job Number: 9/30/01'
5of14
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they
are shown elsewhere in the documents or on this checklist only.
ESCRIPTION Instructions: Check or initial applicable boxes or enter WA if not applicable. I DESIGNER
uilding Envelope Measures
',]41150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
§150(b): Loose fill insulation manufacturer's labeled R -Value.
J.§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to
exterior mass walls).
'§ 150(d): Minimum R-13 raised floor insulation in framed floors.
§ 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch.
f; §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiflration Controls 1.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
pace Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 extemal insulation or R-16
combined intemal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
§150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and
Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed
with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or
UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or
tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated damper
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
__J § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously buming pilot
light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
Lighting Measures
7 §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and
recessed ceiling fixtures are IC (insulation cover) approved.
EnergvPro 3.1 By EnergySoft User Number: 5021 Job Number 9/30/01' Page:6 of 14
Computer'Methold Summary (Part 1 of 3) C -2R
Plan Standard Santa Fe 9/30/2001
Project Title Date
Gas Furnace/Elec Condenser - HVAC La Quinta
Project Address Building Permit #
Energy Management Service 760-360-4631
Documentation Author Telephone Plan Check/Date
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer) Cimate Zone
Source Energy Standard
Use (kBtulsf-yr) Design
Facing
North Margin
❑❑
Facing
East Margin
Facing
South Margin
Facing
West Margin
3.60 0.05
3.83 -0.18
3.80 -0.15
3.62 0.04
Space Heating 3.66
Space Cooling 41.15
36.09 5.06
36.07 5.08
35.88 5.26
36.52 4.63
Domestic Hot Water 16.37
15.25 1.12
EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 9/30/01' Page:7 of 14
15.25 1.121
1 15.25 1.12
15.25 1.12
7
Totals 7
BUILDING
COMPLIES
This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence.
This plan has been analyzed with identical features in all orientations.
GENERAL INFORMATION
Conditioned Floor Area: 1,421 Floor Construction Type: OX Slab Floor
Building Type: Single Fam Detached
❑ Raised Floor
Building Front Orientation: All Four Orientations
Number of Dwelling Units: 1.00 Total Conditioned Volume: 12,789
Number of Stories
Slab Floor Area: 1,421
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAC: Sustem 149 _ 12 78 - _ 1 00 rnndHinnpd SPthnnk _2 _n/a
OPAQUE SURFACES
Type Area U -Val
Solar
Act. Gains
Azm. Tilt Y / N
Form 3 Reference
Location / Comments
Roof 1 421 0.034 0 _o
Wal)_ 318 0.088 0 M
Dnnr 20 0 387 _0 90
nnnr 17 0.387 0 90
Wall 284 0 088 90 90
Wall 132 0 088 _ 90 go
Wall 244 0.088 _ 180 90
Wall 207 0.088 _ 270 90❑
Wall 172 0 088 270 A0
❑❑
R-30 Roof (R 30 2x1216) WhnlP Ho vsP
R-13 Wall (W 13 2x4 18) Whnle Hntjca
Snlid Wnod Dnnr Whnle Hntise
Solid WrM Dnor Whole House
R-13 Wall 0&132x416) Wholp House
R_13 Wall CW 13 2Y4 181 Whole HniiaP
R-13 Wall (W 132x4.16) Whnle Hnuse
R-13 Wall (W 132x4.18) Whole House
R-13 Wall (W 13 2Y4 18) WhnlP Hrnise
EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 9/30/01' Page:7 of 14
Computer Method Summary (Part 2 of 3) C -2R
Plan Standard Santa Fe 9/30/2001
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act. Glazing Type
Azm. Tift
Location/
Comments
_L
Windrnnr—Ewnt (b oNt)
—25.0-
Q_650.
0 40
Q_ _9D Double_C1ear_nefault
-Za ole_l louse
- 2
Window Left (East)
16.7
0.650
0.40
90 90 Fr Door DP Clear Default
Whole House
3
Window Left (East)
9.0
0.650
0.40
90 90 Double Clear Defauft
Whole House
4
Window Rear (South)
4.0
0.650
0.40
180 90 Double Clear Default
Whole House
-• 5
Window Rear (South)
40.0
0.650
0.40
180 90 Sldg Glass Doors Defauft
Whole House
6
Window Rear (,South):
16.0
0.650
0.40
180 90 Double Clear Defauft
Whole House
Z
Wkdgw Right (West)
3.0
0,650
0.40
270 90 LDefsault
Whole House
8
Window Right (West)
16.0
0.650
0.40
270 90 Double Clear Default
Whole House
6
Window Right—(Vest)
M-0-
Q�e0-
0.40
—27-0_ --9Q 2ou�e-C De ult
Whple�2use
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd
Len Hgt LExt REA. Dist. Len. Hgt. Dist. Len. Hg_t.
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
—
EnemyPro 3.1 Rv FnornvCnft User Number. 5021 Job Number. 9/30/01' Page:8 of 14
Computer Method Summary (Part 3 of 3) C -2R
Plan Standard Santa Fe 9/30/2001
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete, Heavyweight 965 3_50 _28 -0.9.8. n/a —2 -Wbol Ho .c /slab on Grade
Concrete, Heavyweight 456 3_50 28 0_98 n/a 0 Whole House / Slab on Grade
PERIMETER LOSSES
F2
Insulation
Type Length Factor
R -Val. Depth Location / Comments
_$jab PeAmeter —Ito -0-
U- ---Q y�hole�iou�P -----
Slab-Berimeter .6 O.Z6
—0-0 --0 WAote-1iause - ---
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location
Duct Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.)
R -Value Type Comments
Ce0tr I Furnace 803LAEUE-
2 ----Se14a;k—_ .li�A�Sestem
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location
Duct Thermostat Location/
heat pump, evap. cooling) (SEER) (attic, etc,)
R -Value Type Comments _
Split Air C nditioner 1? Q_$ EER Duds in Attic
4.2_ --S-etbach — k-iYACaUWe
WATER HEATING SYSTEMS1
1
Rated Tank Energy Fact. 1 Tank Insul.
Water Heater Water Heater Distribution
# in Input Cap. or Recovery Stand byy R -Value
System Name Type Type
Syst. (Btu/hr)(gal) Efficiency Loss (°/a) Ext.
A.O.Smith FSG -40-222 Small Czar Standard
40 Q.56— n/a 12
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated
Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Computer Method Summary (Addendum) C -2R
Plan Standard Santa Fe 9/30/2001
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement aaencv determines the adenuacv of the justification. and may refect a building or design that otherwise complies
)ased on the adequacy of the special justification and documentation submitted. IPlan Field
The DHW Svstem "A.O.Smith FSG -40-222" Energv Factor = 0.560. An EF below 0.58 requires an R-12 EAernal Blanket.
The HVAC System "HVAC Sustem" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 965 sqft Covered Slab Floor, 3.50" thick at Mechanical - One Zone
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 456 sgft Exposed Slab Floor, 3.50" thick at Mechanical - One Zone
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R.
Plan
Field
The HVAC System "HVAC Sustem" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC Sustem" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
I EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 9/30/01' Page: 10 of 14 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Plan Standard Santa Fe 9/30/2001
SYSTEM NAME FLOOR AREA
HVAC Sustem 1,421
SYSTEM LOAD
uursiae Eur tcrrrusgrq u.uul
Note: values above given at ARI conditions
(EATING SYSTEM PSYCHROMETRICS
26.0°F 66.9°F 66.9°F
-01
Outside Air O
0 cfm
66.9 °F
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
I Sensiblel Latent
I I CFM
I Sensible
697
13,013
0
516
19,373
0
651
969
0
0
0
0
0
0
0
0
0
651
969
14,315 OI 21,310
H4DH024/P3HUA08LO32 U&H 16,243 4,687 32,000
Total Adjusted System Output6,243 4,687 32,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
..... Temneratures at Time of Heating Peak%
104.4 OF
Supply Fan Heating Coil
800 cfm
k Return Air Ducts `S
Supply Air Ducts
103.3°F
ROOMS!
68.0 OF
I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
11.0 / 77.6 OF
Outside A
0 cfm
J
78.8 / 65.1 ° F
3.1
78.8/65.1°F 78.8/65.1°F 59.7/58.6°F
O ~i
Supply Fan Cooling Coil
800 cfm
User Number. 5021
Return Air Ducts
Job Number. 9/30/01
Supply Air Ducts
60.5/58.8°F
49.6% R.H. ROOMS
78.0 / 64.8 OF
1
e:11 of 14
FROOM LOAD SUMMARY
PROJECT NAME
Plan Standard Santa Fe
DATE
9/30/2001
SYSTEM NAME
HVAC Sustem
FLOOR AREA
1,421
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Whole House
Mechanical - One Zone
1
697
13,013
0
697
13,013
0
516
19,373
PAGE TOTAL 1 697 13,013 0 516 19,373
TOTAL 1 697 13,013 O]F 516 19,373
EnergyPro 3.1 By Energysoft User Number: 5021 Job Number: 9/30/01' Page: 12 of 14
ROAM HEATING PEAK LOADS 7
Conduction
Items shown with an asterisk (•r) denote conduction through an interior surface to another room. Page Total: 19,373
Infiltration: 1.00 x 1.064 x 1 421 x 9.00 x 6] x 42 = 0
chedule Ai►Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 19,373
EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number: 9/30/01' Page: 13 of 14
Area
X
x
X
X
X
X
X
x
x
x
x
X
X
x
x
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
x
X
X
x
X
X
X
X
X
U -Value
X
X
X
X
X
X
x
x
X
x
x
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
QT of
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
1421.0
0.0341
42.0
2,032
perimeter= 171.0
44.5
7,610
1,358.1
0.0885
42.0
5,047
93.0
0.6500
42.0
2,539
36.7
0.3872
42.0
597
16.7
0.6500
42.0
456
40.0
0.6500
42.0
1,092
Items shown with an asterisk (•r) denote conduction through an interior surface to another room. Page Total: 19,373
Infiltration: 1.00 x 1.064 x 1 421 x 9.00 x 6] x 42 = 0
chedule Ai►Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 19,373
EnergyPro 3.1 By EnergySoft User Number. 5021 Job Number: 9/30/01' Page: 13 of 14
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Plan Standard Santa Fe 9/30/2001
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Conduction
-30 Roof (R.30.2x12.1
-13 Wall (W.13.2x4.-
Area U -Value
Mechanical - One Zone
78°F
112°F
34°F
DETD 1
X 51.0
X 30.6
X 34.0
X 30.6
X 34.0
X 34.0
X
X
X
Btu/hr
2,468
3,677
2,055
435
369
884
1. Design Equivalent Temperature Difference (DETD)
Page Total 9 888
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Window #1 5050 XO HS
(North)
Frenrh Door Wd 2668
(East)
Window #3 3030 XO HS
Window #8 4010 XO HS
(East)
South
Sldg Glass Dr #6 6068
(South)
Window #5 4040 XO HS
South
Window #4 3010 XO HS
(West)
Window #5 4040 XO HS
Window #2 5040 XO HS
est
est
( 0.0
X
X
X
x
X
X
x
x
x
1
+
+
+
+
+
+
+
+
+
+
25.0
X
x
X
x
x
x
X
X
x
x
15)
X
x
x
X
x
x
X
X
x
)x
0.44
=
=
=
=
=
=
=
=
__
=
167
( 0.0
1
16.7
73)
0.44
543
( 0.0
1
9.0
73)
0.44
293
(-0.0
1
4.0
32)
0.44
57
( 0.0
1
40.0
32)
0.445
570
( 0.0
1
16.0
32)
0.445
22E�J
( 0.0
1
3.0
73)
0.445
98
( 0.0
1
16.0
73)
0.445
520
( 0.0x
1
20.0
7)
0.445
650
(
Sched.Page Total 3,125
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,421 x 0.000 Watts/sqft x 3.4 . 13 Btuh/Watt = 0
Occupants 1.00 X 1,421 x Btuh/OCC. / 20.0 sgft/Occ. = 0
Receptacle 1.00 x 1.42 x 0.0 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 x 1,42 x 0.00 Watts/sgft x 3.4133 Btuh/Watt = ��0��
Infiltration: �� x � x x 9D9 x o_oo / 60] L 39J = ==0
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,013
Sched.
Latent Gain Frac. Area Heat Gain etumr
Occupants 1.00 x 1 421 x 0 Btuh/OCC. / 20 0 sgft/OCc. = 0
Receptacle 1.00 X 1 21 X 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Process 1.00 x 1 4 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 00j
Infiltration: 1.00 X 4 77 X 1 42 x 9.00 x 0.00 / 60] 0.00000 = L�
chedule Air Latent Area Ceiling Height ACH DW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0
EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 9/30/01' Page:14 of 14
t-IIiT us
Systems International, LLC.
Truss Engineering & Layouts
8M01'CO[O l Const.
166 Santa Fe
Job #,'A3035K20
1276 N. Palm Canyon Dr., Suite 109- Palm Springs, CA 92262
Offices 760-39 6-269 6 Fax les C> 1 8-2605
c
In
0
Do�
n
Zf?°
��O
-n
(n
�0D�
c
Cm0
ni
M
C
0
Z.
'U
t-IIiT us
Systems International, LLC.
Truss Engineering & Layouts
8M01'CO[O l Const.
166 Santa Fe
Job #,'A3035K20
1276 N. Palm Canyon Dr., Suite 109- Palm Springs, CA 92262
Offices 760-39 6-269 6 Fax les C> 1 8-2605
38-0-0
TO
i:::::::::::::::::::::::::::::::::::::-:::::::,:::::::::•::•:::::,:::::::::::::::::::::::::::::::::::::::::::::::::::::f:'
Sol
I�
T05...........................................................................................................................................................................................................
.............................................................................................................................................................................................................
I
.................. .. .........................I
I
�
TOS::::::::.:::::::::::::.:.:::::::::..:::::::.::::.:::::::::::::.::::::::::::::::::::::::::::::::::::::::.:::::::::.::::::.:::::::::::::::::::::::::::::::.::::::.::::::::::::::::::.:::::
/.
705.1 ::::.:.:.::::::::::.::::.... .......... ::::::.:.:.:::::::::::::::..:.:::::::::::::::::.:.:::::::::::::.:.:.:::::::::::::::::.::.::::::::::::::.::.::::::::::::::::::..:.:.::::::::::::::..........................................................�..
�
TO S. :.::::::............... ..::::::::
�i
I'C5
�I
:.:
297 i
II
I
�yT01
S03
I
OF CAt�F
o
!
,.
I I
I.............................................................................................................................
TOS......................To ............................................................................................................
i
i
li
I
N
S03
I
II
i;
SOS
I
T02I::.::::::.:::.::.....................................................................................................................II
I
Toe.�......:.:..::::,...
li
li
I..................................................................................................................................................................
T05.:................................................................................................................
t.
!
...........................................................................................................I.,
........................:...........:.:...:............................................................................................................
N
{..........:....................................................:..................... ............._........:.........................................................................................................:............................................................I
T O 5...................................................................................................................................................................................................................................................................I.
.
TO
i:::::::::::::::::::::::::::::::::::::-:::::::,:::::::::•::•:::::,:::::::::::::::::::::::::::::::::::::::::::::::::::::f:'
Sol
I
�
'
I
TO;:I
')
II
i S03
II
S03
T041
i
.t
I.!
...........................................................:........................................................
............................................................................................................. .I
S03
SOS
I
T02I::.::::::.:::.::.....................................................................................................................II
I
Toe.�......:.:..::::,...
li
�
S03
I :
I
N
.............,...:.........:.....:......,....:...............,........,...................................................
I.
t
�
i
I
it
i I
is
I
I{..
503=
T O 1'::::::::::::::::::::::::::::::::.:::.:::::::::::::::.:::::::::::::::::::::::.::::::::::::::::::.:::::::::::::::.:::.:::::::::::::.:::::::::
�I
I
:::::::::::::.:::.:::::::I
�a uve n�
TO 11: ............ .:::-:::::::::::::::::::::::::.:::-:::-::::::::::::::-.:::•::::::::::.::::.:-::::::::::,:::.::-::::::::::.::::.::::::::::::::.:::::::::::::,::::.:::::::::::!:!
lo i/ wee, ?Z�.
TO1��.................:...........:..........................:::..:.::::.......,.:::..::.:...............,...:...:.:.:,.....::.:..:.:::::.::::..
,:::::::::,:,::..,.::::::::::::::::..:,:: i
/• 7,6-6>UII�TIO•�l
2,(,4 "�
21-0-0
17-0-0
cO/ AV.-
���l�V % 3y/18-26✓J�P
Job
Truss
Truss Type
S01
SLOPING FLAT
�Qty7117yR10236
1
SOUTHWESTERN
(optional)
IntelliTruss Systems International LLC, Palm Springs, CA 92234
4.200 s Feb 14 2000 MTek Industries, Inc. Tue Oct 09 10:34:52 2001 Page 1
6-6-13
12-10-2 19-4-15
6-6-13
6-3-5 6--13
Scat. •use
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
0.3sFI-2
�+ -------- --
54 =
4 8I
2M It
zxa II z
r
n
'b
_
8
gra 11'
-----------j--------------------------------------------------------------------------------------------------------------------------------------------------------------r--------------_
7 e
axe = axa = It
-
-01'-5 6.6-13 4
12-10-2 19-4-15
0-1-5 6-6.13
6-3-5 6-6-13
Plate Offsets :0.4-0
0.3-09 0-4-80-2-0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (lac) I/deft
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.39
Vert(LL) -0.08 7.8 >999
M20 169/123
TCDL 10.0
Lumber Increase 1.25
BC 0.35
Vert(TL) -0.15 8-9 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.75
Horz(TL) 0.04 5 n/a
BCDL 7.0
Code UBC97/ANSI95
(Matrix)
1st LC LL Min Vdefl = 360
Weight 76 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Sheathed or 5-8-9 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing.
WEBS 2 X 4 WW Std *Except*
WEBS 1 Row at midpt 2-9
4-7 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 10=707/0-3-8,5=707/0-3-8 .,
FORCES (lb) - First Load Case Only
TOP CHORD 1-2--7.2-3---1268.3-4---1270
BOT CHORD 8.9=1355, 75=1355, 6.7=0, 55=0
WEBS 2-8--92.3-7=-419.9-10=-707.1-9=-158.2-7=.100. 4-7=1377.4-5=-669,4-11=0, 2-9=-1448
NOTES
1) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any
other live loads per Table No. 16-B, UBC-97.
2) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TP11-1995 angle to grain formula. Building designer should verity capacity of bearing
surface.
3) This truss has been designed with ANSVTPI 1-1995 criteria.
LOAD CASE(S) Standard
•C 5297
`>�F OF CA��O
Job
Truss
Truss TypeOty
Ply
,
R10238
S02
SLOPING FLAT
1
1
SOUTHWESTERN
(optional)
IntelliTruss Sy`tems International LLC, Palm Springs, CA 92234
4.200 s Feb 14 2000 MiTek Industries, Inc. Tue Oct 09 10:33:40 2001 Page 1
-0-0 4-6-13
10-10-2 17-4-15
-0-0 4-6-13
6-3-5 6-6-13
Scat. • 1a1.s
--------------- : ---------------------------------------------------------------------------------------------------------------------------------------------------------------
0.3a u
--ji-------- -
yA c
41=
m II
2.4 : 11 2
1 ;
4 11
LN
9
2.411
---------------------------------------------------------------------------------------------------------------------------------------------------
T 6
4.12 = U4 = `,h4 11
10
2-0.0 4-6-13
10-10-2 17-4-15
1-6 4-5-7
6-3-5 6-6-13
Plate Offsets[2:0-4-0,0-3-0],[4:0-4-9,0-2-01
LOADING (psf)
SPACING 2.0-0
CSI
DEFL in (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.42
Vert(LL) -0.06 5.7 >999
M20 169/123
TCDL 10.0
Lumber Increase 1.25
BC 0.29
Vert(TL) -0.12 5.7 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.89
Horz(TL) 0.03 5 n/a
BCDL 7.0
Code UBC971ANSI95
(Matri)(
1st LC LL Min Udefl = 360
Weight 68 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD Sheathed or 8-0.0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 WW Std
REACTIONS (Ib/size) 5=629/0.3.8, 10=629/0-3-8
FORCES (lb) - First Load Case Only
TOP CHORD 1-2=5, 2-3=-1080, 3-4=-1082
BOT CHORD 8-9=908,7-8--908, 6-7=0, 5.8=0
WEBS 2-8--T7.3-7=-435,2-7=178, 4-7=1172,9-10-=-629.1-9---95,2-9---1041,
4-5---591,4-11=0
NOTES
1) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
2) Bearing atjoint(s) 10 considers parallel to grain value using ANSVTPI 1-1995 angle to grain formula. Building designer should verity capacity of bearing
surface.
3) This truss has been designed with ANSVTPI 1-1995 criteria.
LOAD CASE(S) Standard
-C 5297:
�91F
0F CAS\F���
Job
Truss—]TNG
Truss 'pe
Oty
ply
r..
R10236 TS'03
SLOPING FLAT
a
1
SOUTHWESTERN
(optionan
IntelliTruss Systems Intemational LLC, Palm Springs, CA 92234
4.200 s Feb 14 2000 MiTek Industries, Inc. Tue Oct 0910:29:08 2001 Page 1
4-6-13
10-10-2 17-4-15
-0-0 4-6-13
6-3-5 6-6-13
scj.-t3i.5
--------------- --------------------------------------------------------------------------------------------------------------------------------------------------------------
0.38 FQ-
...........
54 =
4X
ZIA 11
2.4 II 2
3
LIb
4,811
a
2.411
7
402 = 3.4
17418
-----------------------------------------------------------------------------------------------------------------------
2-0-0 1 4-6-13
10-10-2 17-4-15
2-1-7 4-5-6
6-3-5 6-6-13
Plate Offsets (X.Y): [2:0-4-0.0-3-01,14:0-4-9.0-2-01
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) I/defl
PLATES GRIP
TCLL -20.0
Plates Increase 1.25
TC 0.42
Vert(LL) -0.06 5-7 >999
M20 169/123
TCDL 10.0
Lumber Increase 1.25
BC 0.29
Vert(TL) -0.12 5-7 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.89
Horz(TL) 0.03 5 n/a
BCDL 7.0
Code UBC97/ANSI95
(Matrix)
1st LC ILL Min I/defl = 360
Weight 68 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD Sheathed or6-0-Ooc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 V%fW Std
REACTIONS (lb/size) 5--629/0-3-8,11=629/0-3-8
FORCES (lb) - First Load Case Only
TOP CHORD 1-2--5,2-3---1080, 3-4=-1082
BOT CHORD 8-9=908, 7-8--908, 6-7=0, 5-6=0
WEBS 2-8--77, 3-7=435,2-7=178, 4-7=1172, 4-5---591, 4-10=0, 0-11=-629.1-9=-95,2-9---1041
NOTES -
1) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-97.
2) Bearing at joint(s) 11 considers parallel to grain value using ANSVTPI 1-1995 angle to grain formula. Building designer should verity capacity of bearing
surface.
3) This truss has been designed with ANSI/TPI 1-1995 criteria.
LOAD CASE(S) Standard
�
-C 5297
'N
OF C
Job
Truss
Truss Type
CSI
Ply
PLATES GRIP
R10238
T01
SLOPING FLAT
ICIty
3
1
M20 169/123
TCDL 14.0
Lumber Increase
1.25
BC 0.82
Vert(TL) -0.44 9-11 >564
O tion
J I mceni i russ ayswms imernauonai Lw, rarm apnngs, — aac.r.
13-6-0 27-M
13-6-0 13-6-0
Scale
0.3e 171-2
axe = 11, = axe = 34 = aN II 4X4 =
9-1-3 17-10-13 20-10-4 1 27-0-0
9-1-3 B-9-11 2-11-7 6-1-12
LOADING (psf)
SPACING
2-0-0
CSI
DEFLin (loc) Udefl
PLATES GRIP
TCLL 16.0
Plates Increase
1.25
TC 0.73
Vert(LL) -0.20 11-12 >999
M20 169/123
TCDL 14.0
Lumber Increase
1.25
BC 0.82
Vert(TL) -0.44 9-11 >564
BCLL 0.0
Rep Stress Incr
YES
WB 0.90
Hort(TL) 0.03 8 n/a
BCDL 10.0
Code UBC971ANSI95
1st LC LL Min Wet] = 360
Weight 99 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Sheathed or 4-3-10 oc purlins, except end verticals.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD Rigid ceiling directly applied or 6.0.0 oc bracing.
WEBS 2 X 4 WW Std 'Except*
WEBS 1 Row at midpt 2-12
12-13 2 X 4 SPF 1650F 1.5E, 7-14 2 X 4 SPF 165OF 1.5E
REACTIONS (Ib/size) 12=737/035, 7=-74/03.8, 8=1 47410-3-6
Max Horz 12=274(load case 4)
Max Upliftl2=-219(load case 3), 7=-74(load case 1), 8=-437(load case 4)
Max Gray 7=26(load case 4), 8=1474(load case 1)
FORCES (Ib) - First Load Case Only
TOP CHORD 11-112--11611,11-113--0, 1-2=0, 2-3=-1529, 3d= 1529, 4-5=-41, 55=0, 6-7=-180, (33-14=0
BOT CHORD 11-12=1451.10-11=1230,9-10--i230.8-9---829.7-8---829
WEBS 4.11=329, 4-9=-1312, 55=-1384, 5-9=1098, 5-7=886,2-12=-1531. 2.11=87
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 5.0 psf tap chord dead load and 5.0 psf
bottom chord dead load, 100 mi from hurricane oceanline, on an occupancy category I, condition I enclosed building, of dimensions 45 ft by 24 ft with
exposure C ASCE 7.93 per UBC97/ANS195 If end verticals or cantilevers exist they are exposed to wind. If porches exist they are not exposed to wind.
The lumber DOL increase is 1.33, and the plate grip increase is 1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-8, UBC -97.
4) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 219 Ib uplift at joint 12, 74 Ib uplift atjoint 7 and 437 Ib uplift at
joint 8.
5) This truss has been designed with ANSI/TPI 1.1995 criteria.
6) Design assumes 4)Q (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-1 Od nails.
LOAD CASE(S) Standard
J
m
(e
J
Job
Truss
Truss Type
Oty
Ply
PLATES GRIP
R10238
T02
SLOPING FLAT
8
1
SOUTHWESTERN
TCDL 10.0
Lumber Increase
1.25
BC 0.82
Vert(TL) -0.78 7-9 >320
o tional
InteIIITruss Systems International LLC, Palm Springs, CA 92234 _ 4.200 s Feb 14 2000 MiTek Industries, Inc. Tue Oct 09 10:26:37 2001 Page 1
61a10 1s -as 2140-0
6-10-10 8-1-12 5-11-10
Scald - 1:77
b. =
,o
11-6-2 21-0-0
11-6-2 9-5-14
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in poc) Udell
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.69
Vert(LL) -0.50 7-9 >501
M20 169/123
TCDL 10.0
Lumber Increase
1.25
BC 0.82
Vert(TL) -0.78 7-9 >320
BCLL 0.0
Rep Stress Incr
YES
WB 0.99
Horz(TL) 0.05 6 n/a
BCDL 5.0
Code USC97/ANS195
1st LC LL Min I/deb = 360
Weight 75 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD Sheathed or 4-3.12 oc purlins, except end verticals.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0oc bracing.
WEBS 2 X 4 WW Std 'Except*
WEBS 1 Row at midpt 2-9,4-6
9.10 2 X 4 SPF 1650F 1.5E
REACTIONS (Ib/size) 9=725/03.8, 6=725/0-3.8
FORCES (lb) - First Load Case Only
TOP CHORD 1-9=-202, 1-10=0, 1.2=0, 23=-1627, 3-4=-1627, 4-5=0
BOT CHORD B-9=1706.7-8--1706.6-7=1399
WEBS 2-9=-1768, 2-7=-85, 4-7=264, 4-6=-1487, 5-6=-175, 5.11=0
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 1", UBC -97.
3) This truss has been designed with ANSI/TPI 1-1995 criteria.
4) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.
LOAD CASE(S) Standard
M
C,
Job
Truss
Truss Type
Oty
Ply
F""`-
R10236
T03
SLOPING FLAT
1
1
SOUTHWESTERN
�(optionao
IntellTruss Systems International LLC, Palm Springs, CA 92234
4.200 s Feb 14 2000 MiTek Industries. Inc. Tue Oct 0910:26:01 2001 Page 1
6-0-14
142-8 20-2-8
6-0-14
8-1-10 6-0-0
Scab v ta6.5
2.4 =
ro
3.6 =
3.4 =
3 3
0,38 i
u =
3x4 = S
4
11
LU
3.4 =
8 7
7x4 = 1Y4 = 3.4 =
10-1-4
20-2-8
10-1-4
10-1-4
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Udell
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.65
Vert(LL) -0.30 8-9 >792
M20 169/123
TCDL 10.0
Lumber Increase 1.25
BC 0.76
Vert(TL) -0.48 8-9 >497
BCLL 0.0
Rep Stress Incr YES
WB 0.72
Harz(TL) 0.04 6 n/a
SCOL 5.0
Code USC971ANS195
1st LC LL Min Udeft = 360
Weight 72 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Sheathed or 4.6.15 oc purlins, except end verticals.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2X4WWStd 'Except'
WEBS 1Row atmidpt 2-9,4-6
. 9-10 2 X 4 SPF 165OF 1.5E, 6-112 X 4 SPF 165OF 1.5E
REACTIONS (Ib/size) 9=69710.3-8, 6=697/0-3.8
FORCES (lb) - First Load Case Only
TOP CHORD 1.9=-178, 1.10=0, 1.2=0, 2-3=-1533, 3-4=-1533, 4-5=0, 5-6=-176, 5-11=0
BOT CHORD 8-9=1533.7-8--1334.6-7=1334
WEBS 2-9=-1604, 2-8=-1, 4-8=222, 4-6=-1415
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any
other live loads per Table No. 16-B, UBC -97.
3) This truss has been designed with ANSI/TPI 1-1995 criteria.
4) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC
w/ 2-10d nails.
LOAD CASE(S) Standard
f
�i.
L
.
A
``; 'C 5297
Job
Truss
Truss Type
Oty
ply
DEFL in (loc) Udefl
R10236
T04
SLOPING FLAT
1
1
SOUTHWESTERN
TCDL 10.0
Lumber Increase 1.25
SC 0.61
Vert(rL) -0.46 8-9 >471
(optional)
mrcw nuns oya�crns uucmeumrai mow, rarm apnnys, a,r� v�c.>v
6-0-14
20 =
4.11A1 S I-eD l4 ZWU MI I eK Incustnes, Inc. 1 ue kv1 U9 1u:2D:Ud 2UU1 Nage l
14-2-8 18-2-8 20-2
8-1-10 4-" 2-"
Soak - 1a2.e
m
3:A =
3.4= m=
18-2-8
10-1-4
8-1-4
LOADING (psf)
SPACING 2-041
CSI
DEFL in (loc) Udefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.59
Vert(LL) -0.29 8-9 >735
M20 169/123
TCDL 10.0
Lumber Increase 1.25
SC 0.61
Vert(rL) -0.46 8-9 >471
BCLL 0.0
Rep Stress Incr YES
WB 0.61
Horz(TL) 0.03 6 n/a
BCDL 5.0
Cade USC971ANS195
1 st LC LL Min I/deft = 360
Weight 66 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD Sheathed or 5.43 oc purlins, except end verticals.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
WEBS 2 X 4 WW Std *Except*
WEBS 1 Row at midpt 2-9
9-10 2 X 4 SPF 165OF 1.5E
REACTIONS (Ib/size) 9=627/0.3-8, 6=62710-3-8
FORCES (lb) - First Load Case Only
TOP CHORD i -9---178.1-10--0,1-2--0.2-3=.1174.3.4=.1174,4.5--O
BOT CHORD 8-9--1305.7-a=878.6-7=878
WEBS 2-9=-1365, 2-8=-144, 4-8=330, 4-6=-997, 5-6=-116, 5.11=0
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any
other live loads per Table No. 16-B, UBC -97.
3) This truss has been designed with ANSUTPI 1.1995 criteria.
4) Design assumes 4x2 (flat orientation) purlins at cc spacing indicated, fastened to truss TC
w/ 2-10d nails.
LOAD CASE(S) Standard
-C 5297
--.
Job
Truss
Truss Type
Qty
Ply
R10236
T05
SLOPING FLAT
15
1
SOUTHWESTERN
o bona
,mem tru5Yaywem5 mrernauunai LLw, r•aim apnngs, t ^ e�av
J
4.200 s Feb 14 2000 MiTek Industries, Inc. Tue Oct 09 10:24:33 2001 Page 1 t..
J 5-6-6 10-11-1 16-3-11 21-" 27-0-15 32-5-10 38-0-0
5-6-6 5-4-10 5-4-10 5-4-10 5-4-10 5-4-10 5-6-6
S.M. • 1
2x4 =
21
20
US =
0.38 12
19 18 1.7 16 16 14 13 12 11
314= 3..= 8x10 M18 WB= 4:10= 34= 3.6= 2N II 3.5=
3.4 =
5-6-6 10-11-1 16-3-11 1 21-8-5 1 27-0-15 32-5-10 1 38-0-0
5-6-6 5-4-10 54-10 5-4-10 5-4-10 54-10 5-6-6
LOADING (psf) SPACING 2-M CSI DEFL in (loc) Well PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.88 Vert(LL) -0.80 16 >568 M20 169/123
TCDL 10.0 Lumber Increase 1.25 BC 0.91 Vert(TL) -1.39 16 >324 MIS 141/138
SCLL 0.0 Rep Stress Incr YES, WB 0.99 Horc(TL) 0.23 11 n/a
SCOL .5.0 Code USC971ANS195 1st LC LL Min Udefl = 380 Weight 145 Ib
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Sheathed or 2-3-9 oc purlins, except end verticals.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
WEBS 2 X 4 WW Std *Except* WEBS 1 Row at midpt 2-20,4-19
20.21 2 X 4 SPF 1650F 1.5E, 11-22 2 X 4 SPF 165OF 1.5E 2 Rows at 113 pts 9-11
2-20 2 X 4 SPF 1650F 1.5E, 9-14 2 X 4 SPF 1650F 1.5E
REACTIONS (Ib/size) 20=1320/03-8, 11=132010-3.8
FORCES (lb) - First Load Case Only
TOP CHORD 1-20=-162, 1-21=0, 1-2=0, 2.3=-3391, 3.4=3391, 4.5=-5168, 5.6=-5713, 6-7=-5295, 7-8=-5295, 8-9=-4112, 9.10=0, 10-11=-162, 10.22=0
BOT CHORD 19-20=3390, 18-19=5166, 17-18=5710, 16-17=5710, 1516=5293, 14-15=4110, 1314=2309, 12-13=2309, 11-12=2309
WEBS 2.19=702, 4-18=270, 5-16=-125, 6-15=-489, 8-14---829, 9-1Y54, 2-20=3573, 4-19=-1891, 518=-585, 6.16=454, 8.15=1301, 9-14=2006, 9.11=-2571
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) All plates are M20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
4) This truss has been designed with ANSVrPI 1-1995 criteria.
5) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.
LOAD CASE(S) Standard
-C 5297
qlF OF CM
_ \F'
1�
d