Loading...
12-0886 (SFD)I BOX 1504 78-495 CALLE TAMPICO LA .QUINTA, CALIFORNIA 92253 Tiht " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 12-00000886 Property Address: 52070 AVENIDA MENDOZA APN: 773-2337004-19 -000000- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: COVE RESIDENTIAL Application valuation: 119135 Applicant: Architect or Engineer: CWT [.^AWLI" 90PAZ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professional Code, and my License is in full force and effect. License Class: B. is 14 Date: (! Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls).licensed pursuant to the Contractors' State License Law.). 1 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: CT PROPERTIES, INC. C/O CHRIS CANADAY 3194 AIRPORT LOOP DRIVE #C2 COSTA MESA, CA 92626 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/23/12 Contractor: Dp CT PROPERTIES INC 3194 AIRPORT LOOP DRIVE, # COSTA MESA, CA 92626 JANtO 3(714)327-1710 Lia. No.: 930614 ------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 167794 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should come subject t:g the workers' compensation provisions of Section J Q 3700 of the Labor Cod o. t omply with those provisions. Date: / v �-'Applicant: 1 WARNING: FAILURE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building constru tion, d hereby authorize representatives of this county to enter upon the above-mentioned property rposes. Date: / /41 /JSignature (Applicant or Agent): LQPERMIT Application Number . . . . . 12-00000886 ------ Structure Information 1,817SF DWELLING/VB/RES-3/CL-A/13D [ENG] ----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FIRE SPRINKLERS 13D GARAGE SQ FTG 427.00 PATIO SQ FTG 227.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 1817.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 709.50 Plan Check Fee 461.18 Issue Date . . . . Valuation . . . . 119135 Expiration Date 4/21/13 Qty --•Unit"Charge Per Extension BASE FEE 639.50 20.00 3.5000 -----------------------------------------7---------------------------------- THOU BLDG 100,001-500,000 70.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 102.14 Plan Check Fee 25.54 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/21/13 Qty Unit Charge Per Extension BASE FEE 15.00 1817.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 63.60 427.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.54 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/21/13 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 71.00 Plan Check Fee 17.75 Application Number . . . . . 12-00000886 Permit . . . . . . MECHANICAL Issue Date . . . . Valuation . . . . 0 Expiration Date 4/21/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 3.00 6.5000 EA MECH VENT FAN 19.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 153.00 Plan Check Fee 38.25 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/21/13 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 2.00 .7500 EA PLB GAS PIPE >=5 1.50 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1,817SF DWELLING/VB/RES-3/CLASS-A/13D [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL OR SPA, OR DRIVE WAY APPROACH. 2010 CALIFORNIA BUILDING CODES. October 23, 2012 9:36:10 AM AORTEGA -------=-------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 BLDG STDS ADMIN (SB1473) 5.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 1089.00 ENERGY REVIEW FEE 46.12 DIF FIRE PROTECTION -RES 612.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 334.00 MULTI -SPECIES (MSHCP). FEE 521.00 DIF PARK MAINT FAC - RES 51.00 LQPERMIT . •OL LQPERMIT Application Number . . . . 12-00000886 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF PARKS/REC - RES 1773.00 COVE PRECISE PLAN FEE 100.00 STRONG MOTION (SMI) - RES 11.91 DIF STREET MAINT FAC -RES 158.00 DIF TRANSPORTATION - RES 3592.00 Fee summary Charged Permit Fee Total 1050.64 Plan Check Total 542.72 Other Fee Total 8432.03 Grand Total, 10025.39 Paid Credited Due .00 .00 1050.64 250.00 .00 292.72 .00 .00 8432.03 250.00 .00 9775.39 PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT FERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIWEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org September 11, 2012 Shasta Fire 72-120 Northshore Street Thousand Palms, CA 92276 Re: Residential Fire Sprinkler Plan Review LQ -12 -RS -048 52-070 Avenida Mendoza La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves The completed Contractor's Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure 10.10.1 NFPA13. A warning sign, with minimum '/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Departme to sched a insp ion. Sincerely, Jason tubble Fire Safety Specialist Building Address Owner 7- c6ttfl at 4 e-YCily sic CdS�t /i'i,-s� �� Tel. 5.2 7/710 Contrac f G ! BUILDING: TYPE CONST. 6 OCC. GRP. 3/ A.P. Number . 7 3 a 3 Legal Description /_o r 7 �LK �J�, `/�� "��lT// Project Description S �►Q �, r' r► r 647 GAc cily CoS Z�a G 24=k7/,T.3.27/7/L7 �S S Ft. Size 16317 No. No. Dw. f& Stories Units State Lic. /-� 7 Classif. `f 7 (� �p� Arch Engr. E� �� �C / New Add ElAlter ❑ Repair El Demolition ElDesig Address Tel. / 600 E. IG {!r S /- 4)-,, ¢i3 - City S"4'74IL 4.1 � Zi .2701 State Lic. # 5 3.Y LICENSED CONTRACTOR'S DECLARATION hereby affirm the it nse u er ovr s of Chapter 9 (commenc ng with Section 711) of ➢lvlsion he sin f' s Code, anti my license is In u for a and effect. SIGNATURE ATE WNER-BUILDER DECLARATION Estimated Valuation�j Q I hereby affirm that I am ex�mp[ from the Contractor's License Law for the following reason: (sac. 103r,5, ausinr3ss and Protessions Cade: Any clly or county winch requires a permit to construct alter; improve, demolish, arrepairanysiruature, priers its r'sstranae also requires the applicant for such perr'ft fo rla a siggnrted statement that he is licensed pursuant to fhu povisions of the Conlrscta+'s License Law, Chapter 9 (commencing with Suction 7000) of Division 3 of the Business End Professfons Code, or fhet Ire is exempt fhematram, and the basis (or the alleged exrumrpnon. Aa'y vlora' "ol5octien 7'03'.' fry any applicant fora permirsubjecfs the applic:nr to : croft pan:Ity ether mare than live hundred dollars 1.500). PERMIT AMOUNT Plan Chk. Dep. �7, 0 Plan Chk. Bal. 1] I, as owner of the prvperiy, or my employees with wages as their sole compensation, will do the work, and the structure Is not intended or offered for sale. (Sec. 7044, Business and Ptofes- Sion$ Code: The Corfhacfor's Llconse Law does not apply to an owner of property who builds or impraves fharsafr and wtro doss such work himself or through Iris own amplrryy99es, provfdad that such improvumoil era not infended or offered for sate. If, hdwavet; the hot ding or lm- provament Is sold wlthffr one year of campletfnn, the owner -builder will have (ha burden of Prow that ha did hat bu8d orimpmve for the purpose of sale). ❑ I, as owner of the property, am exclusively con"cting with licensed contractors to construct the project (Sac. 7044. Business and Professions Code: The Conlractor's Ucense Lawdoes not apply 10 an owner of property who builds or Improves thereon, and who contracts for such projects with a canlractor(s) Ucensedpursuanf to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason ConSt. Mech. Electrical PIUmblftg•'. S.M.I. Grading Driveway Enc. � Date Owner Infrastructure i WORKER'S COMPENSATION DECLARATION 2z 1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company f r� ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. ' V. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE Is' section need not be completed if the permit is for one hundred dollars ($100) valuation nr less). 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to became subject to Workers' Compensation Laws of California. TOTAL } Olin' REMARKS r lry� M -_ - — Date Owner NOTICE TO APPLICAfdT. !!, after making this Certfllcate of Exemption you should become subfecf to the Workers' Compensation provisions of the Labor Code, you must forthwilh comply with such provisions or this permit shall be deemed revoked. ZONE: By: Minimum Setback Distances: CONSTRUCTION LENDING AGENCY Front Setback from Center Line I herebyy atflrm that there Is a construction lending agency for the performance of the work for which tt is permit is issued. (Sec. 3097, Civil Code.) Rear Setback from Rear Prop. Line Lender's Name Side Street Setback from Center Line Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify tho I have read this application and state that the above Inforrrravon is correct. I agree to comply with all city and county ordinances and state laws relating to huilding construction, and hereby authorize representaflves of this city to enter the above -mentioned properly for Inspecttan purposes. FINAL DATE Issued by: Side Setback from Property Line INSPECTOR Date Permit • Signature of applicant Date Mailing Address Validated by: City, State, Zip Validation WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE 7'1 Date 1/18/13 No. 31530 Owner CT Properties Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8615 APN # Jurisdiction Permit # No. of Units �WDt' q- ro k' BERMUDA DUNES RANCHO MIRAGE t4) r� INDIAN WELLS �+ di- 1 PALM DESERT y V' LA 4UFNTA %INDIO y, 0 773-233-004 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 52070 Avenida Mendoza 1817 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Certs 31530 & 31 used for cc totaling $11,628.80. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.20 X 1,817 S.F. or $5,814.40 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Citizens Business Bank - Robert Walker Check No. 239545 Bank Name/Recipient of Certificate Telephone 760-275-8731 Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by on Gllvrey Payment Recd $5,814.40 'aver/Under Signature NOTICE: Pursuant 'to Government Code SeLtrbn 66020(d)(1�. this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the dlit on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Tjhf 4 4 a" To: Greg Butler, Building & Safety Manager From: Planning BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 o^ To CDD: q — / .�, I&L4 O� q_a�-ice AT) Building Permit Release (This is an approval to issue a Building Permit) The Community Development Department has reviewed the following project: Description: el-) Address or general location: Jam' -;2 O 7 O APN and or legal description: The Community Development Department finds that: ❑ ...issuance of this Building Permit does not require Community Development Department approval. ❑ ... issuance of this Building Permit is approved by the Community Development Department. CO vr"cG �1- L ti.S 1/V-k2.Ae-( j S e .� `t��r. Me —O ZY IJ y � III Pinrer signature Date KAY'S GRN SHEET.doc 7/15/2004 dl&41131 t( 5A �-Pcel v SEA 1, cnning DePOt"ir U&M T4hf 4 Q MEMORANDUM TO: Building and Safety Department FROM: 6Eric Ceja, Assistant Planner DATE: 8/9/12 RE: 52-070/52-090 AVENIDA MENDOZA CT PROPERTIES, INC. The Planning Department has reviewed the building plans for the above mentioned properties and has the following comments: 1. The "pop" out features for the proposed fireplace and media niche encroach into the five (5) foot side yard setback by one and a half feet (1.5'). The applicant shall correct the plans to maintain the five (5) foot side yard setback on both properties. 2. The architecture for the buildings is acceptable as it incorporate various architectural elements not common to surrounding homes. If you have any questions, please contact me at X7125. Plan Check Memo (52-070, 090 Avenida Mendoza) DOC # 12-0263128 06/07/2012 12:24 PM Fees: $18.00 RECORDING RE")UESTED BY: Page 1 of 2 Doc T Tax Paid First American Title Ins. Co. Recorded in Official Records County of Riverside AND WHEN RECORDED MAIL TO: Larry W. Ward CT Properties, Inc. Assessor, County Clerk & Recorder Chris Canaday 3194 Airport Loop Drive #C2 Costa Mesa, CA 92626 —This document was electronically submitted to the County of Riverside for recording' Receipted by: YSEGURA • -�� THIS SPACE FOR RECORDER'S USE ONLY: Title Order No.: 4054380 Escrow No.: 004833-KG GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $67.10 [X] computed on full value of property conveyed, or [ J computed on full value less value of liens oar encumbrances remaining at time of sale. [ J Unincorporated area [Xj City of LA q vm FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Lillian R. Zelisse, a Married Woman, as her sole and separate property hereby GRANT(s) to: CT Properties, Inc., a California Corporation the real property in the City of La Quinta, County of Riverside, State of California, described as: LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF Also Known as: Vacant Land - APN 773-233-004-5, La Quinta, CA AP#: 773-233-004-3 Tra-1Q2o -U1 DATED May 22, 2012 STATE OF CAUFO r COUN OF On _ I Z before me, A+ Nyta Pubtic in �qd for said State personally appeared trl � l 1 ct n I�L —) .P k i 5 SP illi In R. Zelisse who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/W6 subscribed to the within C. BLAUS€R instrument and acknowledged to me that lie/shehhey- _ Commission # 1822306 executed the same in hislherlttw-if authorized capacity(ies), Notary Public - California i and that by hWher/their signature(s) on the instrument the Orange County person(s), or the entity upon behalf of which the person(s) M Comm, Expires Noy 11, 2012 acted, executed the instrument. I certify under PERALTY OF PERJURY under the laws of the State of Callfomia that the oregoing paragraph is true and correct. WITNESS my hyid #d oliicia Signature --- / " (Seal) MAIL TAX STATEMENTS TO PARTY SHOWN BELOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE: EXHIBIT "A" Real property in the City of Riverside, County of Riverside, State of California, described as Follows: LOTS 18 AND 19 IN BLOCK 94 OF UNIT NO. 11, SANTA CARMALITA AT VALE LA QUINTA, AS SHOWN BY MAP ON FILE IN BOOK 18 PAGE 75 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA. APN: 773-233-004-3 and 773-233-005-4 Title 24 Energy Report 52-070 AVENIDA MENDOZA The Cove, Plan 1BR La Quinta Climate Zone #15 2008 Building Energy Efficiency Stan BEG Project No.: 12053 RE ,:.IVE 0 AUG 0 8 2012 BY: CT Properties, Inc. !"NIP CITY OF (-A QUINITA BUILDING & SAFETY DEPT. APPR FOR CONSTRUCTION DATE 10 W1- BY Heritage Energy Group, LLC July 26, 2012 Title 24 Energy Calculations Tel: (949) 789-7221 / Fax: (949) 789-7222 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 Project Address 52 t d d -070 A 'M ****** � La Quinta *v8.1* Documentation Author... Rudy Sains ****** Building Permit # Heritage Energy Group, LLC 470 Wald Plan Check / Date Irvine, CA 92618 (949) 789-7221 Field Check/ Date Climate Zone........... 15 Compliance Method.,.... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-12053P1B Wth-CTZ15S08 User#-MP0940 User -Heritage Energy Group, LL Run- MICROPAS8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin Improvement Space Heating.......... 3.38 3.93 -0.55 -16.3o Space Cooling.......... 77.01 63.86 13.15 17.10 Ventilation Fans....... 1.06 1.06 0.00 0.0% Water Heating.......... 17.26 12.03 5.23 30.3% Total 98.71 80.88 17.83 18.10 *** Building complies with Computer Performance *** *** HERS Verification Required for Compliance *** r .,,it .6 GENERAL INFORMATION HERS Verification.......... Conditioned Floor Area..... Building Type .............. Construction Type ......... Natural Gas at Site ....... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-factor... Average Glazing SHGC....... Average Ceiling Height..... Required 1817 sf Single Family Detached New Yes Front Facing 270 deg (W) 1 1 FullYear Slab On Grade 1 18170 cf 1817 sf 16.7 % of floor area 0.33 Btu/hr-sf-F 0.22 10 ft Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 Zone Type Residence BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo - Area Volume Dwell Peop- it- stat (sf) (cf) Units le ioned Type 1817 18170 1.00 6.0 Yes Setback ATTIC AND ROOF DETAILS Vent Vent Verified Height Area Leakage or (ft) (sf) Housewrap 2.0 Standard 3 SLA Frame R- R- Roof Roof Re- Emiss- Frame Spac- Value Value Vent Mass Rise flect- ivity Depth ing Above Below Area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck Deck Ratio High Tile Heavy 4:12 0.10 0.85 3.5 24 oc 0.00 0.00 1/300 0.00 OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments 1 Wall Wood 302 0.072 13 4 90 90 Yes 4.3.1 C3 2 Wall Wood 429 0.072 13 4 0 90 Yes 4.3.1 C3 3 Wall Wood 134 0.072 13 4 270 90 Yes 4.3.1 C3 4 Wall Wood 402 0.072 13 4 180 90 Yes 4.3.1 C3 5 Wall Wood 210 0.102 13 0 270 90 No 4.3.1 A3 6 AtticRad Wood 1817 0.031 30 0 n/a 0 Yes 4.2.1 A20 7 Door Wood 24 0.500 0 0 270 90 Yes 4.5.1 A4 8 Door Wood 21 0.500 0 0 270 90 No 4.5.1 A4 PERIMETER LOSSES Appendix Length F2 Insul Solar JA4 Location/ Surface (ft) Factor R-val Gains Reference Comments 9 S1abEdge 178 0.730 R-0/Oin No 4.4.7 Al Standard Slab Edge Orientation 1 Door Back (E) 2 Wind Back (E) 3 Wind Back (E) 4 Wind Left (N) 5 Wind Left (N). 6 Wind Left (N) 7 Door Front (W) FENESTRATION SURFACES Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments 48.0 0.350 0.220 90 90 Standard 1/Vinyl Frame/S.G.D./Low 30.0 0.340 0.220 90 90 Standard 2/Vinyl Frame/Operable/L 20.0 0.340 0.220 90 90 Standard 3/Vinyl Frame/Operable/L 25.0 0.340 0.220 0 90 Standard 4/Vinyl Frame/Operable/L 6.0 0.340 0.220 0 90 Standard 5/Vinyl Frame/Operable/L 30.0 0.340 0.220 0 90 Standard 6/Vinyl Frame/Operable/L 56.0 0.270 0.210 270 90 Standard 7/French Door low-e Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 Orientation 8 Door Right (S) 9 Wind Right (S) FENESTRATION SURFACES Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments 48.0 0.350 0.220 180 90 Standard 8/Vinyl Frame/S.G.D./Low 40.0 0.340 0.220 180 90 Standard 9/Vinyl Frame/Operable/L OVERHANGS Window— erhan Area Left Right Surface (sf) Width Height Depth Height Extension Extension 1 Door 48.0 n/a 8 13 0 n/a n/a 8 Door 48.0 n/a 8 12 0 n/a n/a SLAB SURFACES Area Slab Type (sf) Standard Slab 1817 HVAC SYSTEMS System Minimum Type Efficiency Furnace ACSplit Verified Verified Verified Verified Verified Maximum Refrig Charge Adequate Fan Watt Cooling EER or CID Airflow Draw Capacity 0.800 AFUE n/a n/a n/a n/a n/a 14.00 SEER 12 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) Furnace 27728 n/a n/a n/a ACSplit n/a 21438 26604 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R-value Leakage Area Ducts Furnace Attic R-8 Yes No No ACSplit Attic R-8 Yes No No Tank Type INFILTRATION TESTING DETAILS Blower Door Blower Door Leakage Target Leakage Minimum (CFM50h/SLA) (CFM50h/SLA) 1427 / 3.0 714 / 1.5 FAN SYSTEMS System Type Flow Power (cfm) (W/cfm) Standard 63.17 .25 WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Type Distribution Type System Factor (gal) R-value 1 SmallTankless Gas StandardNoInsul 1 0.82 n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION R-n/a *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-4R installation certificate. *** This building incorporates HERS verified High Quality Insulation Installation. This building incorporates HERS verified Building Envelope Sealing. Target and Minimum CFM values measured at 50 pascals are shown in Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 HERS REQUIRED VERIFICATION INFILTRATION TESTING DETAILS above. If the measured CFM50h is above the target, then corrective action must be taken to reduce the infiltration and then retest. Alternatively, the compliance calculations could be redone without infiltration testing. This building incorporates a HERS verified Improved Refrigerant Charge test or the installation of a HERS verified Charge Indicator Display (CID). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified High Energy Efficiency Ratio (EER). This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF-4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. REMARKS Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: Ca10ERTS, Inc CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6 Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Name.... Rudy Sains Company. CT Properties, Inc. Company. Heritage Energy Group, LLC Address. 3194 Airport Loop Drive Address. 470 Wald Costa Mesa, CA Irvine, CA 92618 Phone... 714-327-1710 Phone... (949) 789-7221 License. Signed.. Name.... Title... Agency.. Phone... Signed.. ENFORCEMENT AGENCY te) (date Signed.. Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 7/26/2012 (date) Electronically Filed by Rudy Sains and Authenticated at CalCERTS.com - 7/26/2012 Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc -Mandatory Measures Summary MF-IR Residential (Pase 1 of 3) Site Address: Enforcement Agency: Date: NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1R, CF-IR-ADD, or CF-1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum componentperformance specifications whether they are shown elsewhere in the documents or in this summary. Submit all a licable sections of the MF-IR Form with plans. DESCRIPTION Building Envelope Measures: § 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of § 10-11l(a). § 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. § 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. § 118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of § 118(i) when the installation of a Cool Roof is specified on the CF-lR Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U-factor. § 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U-factor: *§ 150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U-factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-lR Form. § 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150(e)lA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readfly accessible, o erable, and ti ht-fittingdamper and or a combustion -air control device. § 150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110-§ 113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. § 113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. § 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(r 1 §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. § 1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. § 1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. § 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. § 1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 2008 Residential Compliance Forms August 2009 -Mandatory Measures Summary MF-1R Residential (Page 2 of 3 Site Address: Enforcement Agency: Date: 1500 j4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Ducts and Fans Measures: §150(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or toe shall be used §150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. § 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150(m)7: Exhaust fan systems have back draft or automatic dampers. § 150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. § 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. § 150(o): All dwelling units shall meet the requirements of ANSFASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: § 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. § 114(b)l: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating § 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. § 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p). Residential Lighting Measures: §150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by § 150(k)2. § 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d). § 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. § 150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by § 130(d), and shall not contain a medium screw -base socket. § 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of § 150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed Iighting in kitchens shall be highefficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 If or 100 watts for dwelling units larger than 2,500 fig may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (FMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. § I50(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. 2008 Residential Compliance Forms August 2009 Mandatory Measures Summary MF-1R Residential (Page 3 of 3) Site Address: Enforcement Agency: Date: EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of § 119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupant sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the applicable requirements of § 119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with § 150(k)11. § 150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. § 150(k)13: Luminaires providing outdoor lighting, including ligbting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception) to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. § 150(k)14: Internally iiluminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130(d). § 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131. 134. and 146 §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicablc requirements of § 119. 2008 Residential Compliance Forms August 2009 RFC /7 wrightsoft` Load Short Form Entire House True Air Mechanical By_ AUG 0 8 2012 For: Avenida Mendoza, Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 .- j Htg Clg Infiltration Outside db (°F) 45 111 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 25 36 Fireplaces 1 (Average) Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 20 -6 HEATING EQUIPMENT Make Carrier Trade CARRIER Model 58STX110-22" AHRI ref no. 2000822 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 105000 Btuh 85000 Btuh 44 °F 1767 cfm 0.091 cfm/Btuh 0.50 in H2O COOLING EQUIPMENT Make Carrier Trade AIRSTAR, TFC, MERIDIAN Cond CA16NA060*"*A Coil ASF*6026A28G++D+V or EQUAL AHRI ref no. 4724581 Efficiency 12.0 EER, 14.5 SEER Sensible cooling 37100 Btuh Latent cooling 15900 Btuh Total cooling 53000 Btuh Actual air flow 1767 cfm Air flow factor 0.055 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.96 ROOM NAME Area OF) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MBA 108 2689 3204 245 175 MBR 264 2846 4925 259 269 WIC 51 941 831 86 45 BDR3 175 1938 3574 177 195 BA2 63 749 1027 68 56 MBR2 196 2204 4515 201 247 HALL2 54 0 0 0 0 HALL 106 0 0 0 0 LAU 48 93 195 8 11 GREAT RM 328 4972 7311 453 400 KIT r11 KI Aln 198 dno 329 nBnA 2932 nono 30 nnn 160 nno VII1 I`IV AO LVGY JOVO 40t7 GVO Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wright50ft" Right -Suite® Universal 2012 12.0.02 RSU11227 ...nls and SettingsVib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc= MJB Front Door faces: 2012-Jul-31 08:45:54 Page 1 Entire House d 1788 19384 32322 1767 1767 Other equip loads 0 0 Equip. @ 1.16 RSM 37558 Latent cooling 1427 -/ Al n A AAf n I I V I P9LV I UU I vJU•t OUCIOU !IV! I/ V/ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti Wrl nt$ai 2012-Jul-3108:45:54 9 Right-Suite®Universal201212.0.02 RSU11227 Page nts and Settings\lib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJS Front Door faces: Building Analysis Job: Avenida Mendoza Lot 19 wrightsoft° Date: Jul 27, 2012 Entire House By: True Air Mechanical True Air Mechanical Plan: Lot 19 Project Information_ For: Avenida Mendoza. Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 ]esitlrn Conditir Location: Indoor: Heating Cooling La Quinta, CA, US Indoor temperature (OF) 70 75 Elevation: 476 ft Design TD (OF) 25 36 Latitude: WN Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 20.1 -5.8 Dry bulb (OF) 45 111 Infiltration: Dailyrange (OF) - 27 ( H ) Method Simplified Wet bulb (°F) - 73 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heating -4 Component Btuh/ft2 Btuh % of load Walls 2.3 2401 12.4 Glazing 9.3 1932 10.0 Doors 0 0 0 Ceilings 0.8 1447 7.5 Floors 1.7 3128 16.1 Infiltration 2.1 2666 13.8 Ducts 7809 40.3 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 19384 100.0 -- Cooling Component Btuh/ft2 Btuh % of load Walls 3.6 3744 11.6 Glazing 27.6 5715 17.7 Doors 0 0 0 Ceilings 1.5 2743 8.5 Floors 0 0 0 Infiltration 1.3 1633 5.1 Ducts 15677 48.5 Ventilation 0 0 Internal gains 2810 8.7 Blower 0 0 Adjustments 0 Total 32322 100.0 Latent Cooling Load =1427 Btuh Overall U-value = 0.073 Btuh/fF-°F Data entries checked. N -N- 2012-Jul-31 08:45:54 111iCfQhtlbt Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1 + ...nts and SetbngsUibB.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Doorfaces: Component Constructions Job: Avenida Mendoza Lot 19 WrlghtsQft° Entire House Date: Jul 27, 2012 By: True Air Mechanical True Air Mechanical Plan: Lot 19 Project Information For: Avenida Mendoza, Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 Design Conditions Location: Indoor: Heating Cooling La Quinta, CA, US Indoor temperature (OF) 70 75 Elevation: 476 ft Design TD (OF) 25 36 Latitude: 34°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gdlb) 20.1 -5.8 Dry bulb (OF) 45 111 Infiltration: Dailyrange (OF) - 27 (H ) Method Simplified 1IUet bulb (°F) - 73 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fr Bhfi/fl -°F R'-° F/Btuh BUMP Btuh Btuh/W Btuh Walls 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 5/8" gypsum board int fnsh, 2"x4" wood frm Partitions (none) Windows 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk: 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk 10D-f: 2 glazing, clr outr, air gas, insulated fiberglass frm mat, clr low-e innr, 1/4" gap, 1/8" thk Doors (none) Ceilings 16D-30td: Attic ceiling, tile, slate, concrete roof mat, r-30 cell ins, 5/8" gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile fir fnsh ne 315 0.091 13.0 2.30 725 3.59 1131 se 59 0.091 13.0 2.30 136 3.59 212 sw 429 0.091 13.0 2.30 988 3.59 1540 nw 240 0.091 13.0 2.30 553 3.59 862 all 1043 0.091 13.0 2.30 2401 3.59 3744 ne 40 0.350 0 8.85 354 26.9 1074 sw 61 0.350 0 8.85 540 29.0 1770 nw 50 0.350 0 8.85 443 26.9 1343 all 151 0.350 0 8.85 1337 27.7 4187 se 56 0.420 0 10.6 595 27.3 1528 1788 0.032 30.0 0.81 1447 1.53 2743 125 0.989 0 25.0 3128 0 0 1iVii91iftQit' Rig ht-Suite®Universal 2012 12.0.02 RSU11227 2012-Jul-31 08:45:55Page 1 nts and SettingsUib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces: Project Summary Job: Avenida Mendoza Lot 19 Wrightsoft` Date: Jul 27, 2012 Entire House By: True Air Mechanical True Air Mechanical Plan: Lot 19 For: Avenida Mendoza, Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 Notes: Design Information Weather: La Quinta, CA, US Winter Design Conditions Outside db 45 OF Inside db 70 OF Design TD 25 OF Heating Summary Structure 11575 Btuh Ducts 7809 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 19384 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 1 (Average) Heating Cooling Area (ft� 1788 1788 Volume (fls) 17878 17878 Air changes/hour 0.33 0.14 Equiv. AVF (cfm) 97 42 Heating Equipment Summary Make Carrier Trade CARRIER Model 58STX110-22* AHRI ref no. 2000822 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 105000 Btuh 85000 Btuh 44 OF 1767 cfm 0.091 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 111 OF Inside db 75 OF Design TD 36 OF Daily range H Relative humidity 50 % Moisture difference -6 gr/lb Sensible Cooling Equipment Load Sizing Structure 16645 Btuh Ducts 15677 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 1.16 Equipment sensible load 37558 Btuh Latent Cooling Equipment Load Sizing Structure 1238 Btuh Ducts 189 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 1427 Btuh Equipment total load 38985 Btuh Req. total capacity at 0.70 SHR 4.5 ton Cooling Equipment Summary Make Carrier Trade AIRSTAR, TFC, MERIDIAN Cond CA16NA060****A Coil ASF*6026A28G++D+V or EQUAL AHRI ref no. 4724581 Efficiency 12.0 EER, 14.5 SEER Sensible cooling 37100 Btuh Latent cooling 15900 Btuh Total cooling 53000 Btuh Actual air flow 1767 cfm Air flow factor 0.055 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 Wi1 111t15dt 2012-Jul-3108:45:55 ` Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1 I9l.C� ...nts and SetBngsVib6.LIBERTYHEATING\Desktop\Mendoza\Lot19.rup Calc = MJ8 Front Door faces: +- wrightsoft° AED Assessment Entire House True Air Mechanical For: Avenida Mendoza, Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 Design Conditions Location: Indoor: Heating Cooling La Quinta, CA, US Indoor temperature (T) 70 75 Elevation: 476 ft Design TD (°F) 25 36 Latitude: 34°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gNlb) 20.1 -5.8 Dry bulb (°F) 45 111 Infiltration: Dailyrange (°F) - 27 ( H ) VVet bu I b (° F) - 73 Wind speed (mph) 15.0 7.5 / Hourly Test for Adequate Exposure Diversity Hourly Glazing Load I � I- 13 14 15 Hour of Day / Average Maximum hourly glazing load exceeds average by 20.7%. 1 16 17 16 19 3] AED limtt House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Wrl htt$dW 2012-Jul-3108:45:55 g Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1 ...nts and SettingsUib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces: + wrightsoft• Right-M Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 1 Room name Entire House MBA 2 Exposed wall 125.0 ft 20.0 ft 3 Room height 10.0 ft d 10.0 ft heat/cool 4 5 Room dimensions Room area 1787.8 ft' 1.0 x 107.8 ft 107.8 ft' Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load number (Btuh/ft;"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y/ G 12C-Osw 0.091 ne 2.30 3.59i 355 315 725 1131 0 0 0 0 2 glazing, clr outr, 0.350 ne 8.85 26.86 40 0 354 1074 0 0 0 0 V+/ I—' 12C-Osw 0.091 se 2.30 3.59 115 59 136 212 0 0 0 0 11 10D-f 12C-0sw 0.420 0.091 se sw 10.63 2.30 27.28 3.59 56 490 0 429 595 988 1528 1540 0 110 0 110 0 253 0 395 Vj/ 2 glazing, dr outr, 0.350 sw 8.85 29.01 61 0 540 1770 0 0 0 0 y/ 12C-Osw 0.091 nw 2.30 3.59 290 240 553 862 90 70 161 251 2 glazing, clr outr, 0.350 nw 8.85 26.86 50 0 443 1343 20 0 177 537 —G C 16D•30td 0.032 0.81 1.53 1788 1788 1447 2743 108 108 87 165 F 22A-tpl 0.989 25.02 0.00 1788 125 3128 0 108 20 500 0 61 c) AED excursion 0 140 Envelope loss/gain 8909 12202 1179 1388 12 a) Infiltration 2666 1633 427 261 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 11575 16645 1606 1650 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 11575 16645 1606 1650 15 Duct loads 67 % 94% 7809 15677 67% 94% 1083 1554 Total room load 19364 32322 2689 3204 Air required (cfm) 17671 17671 245 175 Calculations approved bx ACCA to meet all re uirements of Manual J 8th Ed. wri�istsof# 2012-Jul-3108:45:55 Right -Suite 9 Universal 2012 12.0.02 RSU11227 Page 1 nts and SettingsUlb6.LIBERTYHEATING10esktopWend ozalLotl9.rup Calc = MJ8 Front Doorfaces: + wrightsoft• Right-M Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 1 Room name MBR WIC 2 Exposed wall 18.5 it 7.5 ft 3 Room height 10.0 it heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 263.8 ft 263.8 ft' 1.0 x 51.3 ft 51.3 ft2 Ty Construction U-value Or HTM Area (fN) j Load I Area (ft') Load number (Btuh/ft;°F) (Btuh/f l2) or perimeter (ft) I (Btuh) or perimeter (ft) I (Btuh) Heat I Cool j Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vp/ G 12C-0sw 0.091 ne 2.30 3.59 0 0 0 0 0 0 0 0 2 glazing, Gr outr, 0.350 ne 8.85 26.86 0 0 0 0 0 0 0 0 V/1 12C-Osw 0.091 se 2.30 3.59 0 0 0 0 0 0 0 0 1OD-f 0.420 se 10.63 27.28 0 0 0 0 0 0 0 0 G Vj/ I—( 11 12C-Osw 0.091 sw 2.30 3.59 0 0 0 0 75 75 173 269 2 glazing, dr outr, 0 350 sw 8.85 29.01 0 0 0 0 0 0 0 0 V+l 12C-0sw 0.091 nw 2.30 3.59 185 155 357 556 0 0 0 0 2 glazing, clr outr, 0.350 nw 8.85 26.86 30 0 266 806 0 0 0 0 —G C 16D-30td 0.032 0.81 1.53 264 264 214 405 51 51 41 79 F 22A-tpl 0.989 25.02 0.00 264 19 463 0 51 8 188 0 6 c) AED excursion 581 18 Envelope loss/gain 1299 1824 402 330 12 a) Infiltration 395 242 160 98 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1694 2526 562 428 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 10 0 0 14 Subtotal 1699 2536 562 428 15 Duct loads 67% 94% 1146 2389 67% 94% 379 403 Total room load 2846 4925 941 831 Air required (cfm) 259 269 I 86 45 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed WrirgFtrts4t 2012-Jul-31 08:45:55 Right -Suited Universa1201212.0.02 RSU11227 Paget nts and SetlingslNMUBERTYHEAT INGIDesktoplMendozMLot19.rup Calc = MJ8 Front Doorfaces: * wrightsoft- Right-M Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 1 Room name BDR3 BA2 2 Exposed wall 12.0 ft 5.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 175.0 ft 175.0 ft' 12.5 x 5.0 ft 62.5 ft' Ty 1 Construction number U-value (Btuh/ft;.F) Or HTM (Btuh/ft2 i Area (ft') I or perimeter ft () i Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool 6 Vt/ �{ 12C-Osw 2 glazing, olr outr, 12C-Osw 0.091 0.350 0.091 ne ne se 2.30 8.85 2.30 3.59 26.86 3.59 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 10D-f 0.420 0.091 se sw 10.63 2.30 27.28 3.59 0 120 0 95 0 219 0 341 0 50 0 44 0 101 0 158 V"12C-Osw 2 glazing, clr outr, 12C-Osw 2 glazing, clr outr, 0.350 0.091 0.350 sw nw nw 8.85 2.30 8.85 29.01 3.59 26.86 25 0 0 0 0 0 221 0 0 725 0 0 6 0 0 0 0 0 53 0 0 174 0 0 V)/ t-G C F I 16D-30td 22A-tpl 0.032 0.989 0.81 25.02 1.53 0.00 175 175 175 12 142 300 269 0 63 63 63 5 51 125 96 0 6 I c) AED excursion 1841 1 117 Envelope loss/gain 882 1419 1 1 330 445 12 a) Infiltration 256 157 107 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 1 1138 18061 437 1 510 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 19 1157 0 35 1840 0 10 447 0 19 529 15 Duct loads 67% 94% 781 1733 67% 94% 302 498 Total room load Air required (cfm) 1938 177 i 3574 195 749 68 1027 56 Calculations aggroved by ACCA to meet all requirements of Manual J 8th Ed. wrigtr,tts�f# Righ!-SulteO Universa12012 12.0.02 RSU11227 2012-Jul-31 08:45:55Page3 nts and Setdngsllib6.LIBERTYHFATING1DesktopWendozalLotl9.rup Calc = MJ8 Front Door faces: fir'- wrightsott- Right-M Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 Br: True Air Mechanical Plan: Lot 19 1 Room name MBR2 HALL2 2 Exposed wall 13.5 ft 0 It 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 1 4 5 Room dimensions Room area 1.0 x 195.8 ft 195.8 ft' 4.0 x 13.5 ft 54.0 ft' Ty Construction U-value Or I HT M I Area (ft') Load I Area (ft') I Load L number (Btuh/ftkOF) (Btuh/ft or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool j 6 V"12C-Osw 0.091 ne I 2.30 3.59 0 I 0 0 0 0 0 0 0 2 glazing, Gr outr, 0.350 ne 8.85 26.86 0 0 0 0 0 0 0 0 Vt/ 12C-Osw 0.091 se 2.30 3.59 0 0 0 0 0 0 0 0 10D-f 0.420 se 10.63 27.28 0 0 0 0 0 0 0 0 —G Vt! L--G 11 12C-Osw 0.091 sw 2.30 3.59 135 105 242 377 0 0 0 0 2 glazing, clr outr, 0.350 sw 8.85 29.01 30 0 266 870 0 0 0 0 V)/ t—G 12C-Osw 0.091 nw 2.30 3.59 0 0 0 0 0 0 0 0 2 glazing, clr outr, 0.350 nw 8.85 26.86 0 0 0 0 0 0 0 0 C 16D-30td 0.032 0.81 1.53 196 196 158 300 54 54 44 83 F 22A-tpl 0.989 25.02 0.00 196 14 338 0 54 0 0 0 61 c) AED excursion 961 1 13 Envelope loss/gain 1 1004 16441 1 1 44 80 12 a) Infiltration 288 176 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1292 2280 1 44 80 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 25 45 -44 -80 14 15 Subtotal I Duct loads 67% 94% 1316 888 2325 2190 67% 9 0 0 04% 0 l room load 2201 204 4247 I Ao�equired (cfm) I I I I I I 0 0 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed, wriiUbtsvft 2012-Jul-31 08:45:55 Right-Suit"Unlversa1201212.0.02 RSU11227 Page4 nts and Settings11ib6.LIBERTYHEATING%DesktoplMendoza\Lotl9.rup Calc= MJ8 Front Doorfaces: -q wrightsoftt Right-M Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 1 Room name HALL LAU 2 Exposed wall O ft O ft 3 Room height 10.0 It heaticool 10.0 ft heat/cool 4 Room dimensions 1.0 x 106.3 ft 6.0 x 8.0 ft 5 Room area 106.3 ft' 48.0 ft' T y I Construction U-value Or -ITM i Area ft' I Load I Area ft' Load number (Btuh/ft;°F) (Btuh/ft2 I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vi/ 12C-Osw 0.091 ne 2.30 3.59 0 0 0 0 0 ❑ 0 0 L 2 glazing, clr outr, 0.350 ne 8.85 26.86 ❑ 0 0 0 0 ❑ 0 0 --G 12C-Osw 0.091 se 2.30 3.59 0 0 0 0 0 O 0 0 1013-f 0.420 se 10.63 27.28 0 0 0 0 0 0 0 0 V+/ 11 12C-Osw 0.091 sw 2.30 3.59 ❑ 0 0 0 0 0 0 0 �(^ 2 glazing, dr outr, 0.350 sw 8.85 29.01 0 0 0 0 0 0 0 0 Vj/ 12C-Osw 0.091 nw 2.30 3.59 0 0 0 0 0 0 0 0 t---G 2 glazing, dr outr, 0.350 nw 8.85 26.86 0 0 0 0 0 0 0 0 C 16D-30td 0.032 0.81 1.53 106 106 86 163 48 48 39 74 F 22A-tpl 0.989 25.02 0.00 105 0 0 0 48 ❑ 0 0 61 c) AED excursion -6I -3 Envelope loss/gain 88 157 1 1 39 71 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants (S1 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 86 157 39 71 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -86 -157 16 30 14 Subtotal 0 0 55 101 15 Dud loads 67% 94% 0 0 67% 94% 37 95 Total room load 0 0 1 1 93 195 Air required (cfm) 0 0 8 11 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. 2012-Jul-3108Pa: Rig ht-Sulte4t+Unlversal207212.0.02 RSU11227 pagee s ...nts and Setfings11lb6.LIBERTYHEATINGOesktuplMandozalLoll9.rup Calc = MJ8 Front Door faces: + wrightsoft- Right-J® Worksheet Job: Avenida Mendoza Lot 19 Entire House Date: Jul 27, 2012 By- True Air Mechanical True Air Mechanical Plan: Lot 19 1 2 3 4 5 Room name Exposed wall Room height Room Room area dimensions Ty Construction number U-value (Btuh/ftk'F) Or HTM (Btuh/ft2) Heat Cool GREAT RM 32.0 ft 10.0 ft heat/cool 1.0 x 327.8 ft 327.8 ft Area (ft') Load I or perimeter (ft) + (Btuh) Gross N/P/S Heat Cool 10.0 197.8 Area or perimeter Gross KIT 0 ft ft heat/cool 1.0 x 197.8 ft' (ft') f Load (ft) l (Btuh) ft N/P/S Heat Cool 6 V+l 12C-Osw �G 0.091 ne 2.30 3.59 190 190 437 682 a ❑ 0 0 2 glazing, dr outr, 0.350 ne 8.85 26.86 0 0 0 0 0 0 0 0 V�/ 12C-Osn' 0.091 se 2.30 3.59 115 59 136 212 0 0 0 —G 10D-f 0.420 se 10.63 27.28 56 0 595 1528 0 0 0 0 0 11 V�V 12C-Osw 0.091 sw 2.30 3.59 0 0 0 0 0 0 0 l� 2 glazing, clr outr, 0.350 sw 8.85 29.01 0 0 0 0 0 0 0 0 Vt/ 12C-Osw 0.091 nw 2.30 3.59 15 15 35 54 ❑ 0 ❑ 0 L—G 2 glazing, clr outr, 0.350 nw 8.85 26.86 0 0 0 0 0 0 0 0 C 16D-30td F 22A-tpl 0.032 0.81 1.53 328 328 265 503 198 198 160 0 303 0.989 25.02 0.00 328 32 801 0 198 0 0 0 8 c) AED excursion 123 60 Envelope loss/gain 2269 2855 1 160 1 243 12 a) Infiltration 683 418 0 0 b) Room ventilation 0 ❑ 0 0 13 Internal gains: Occupants @ 230 2 460 0 Appliances/other 0 0 1200 Subtotal (lines 6 to 13) 2951 3733 160 1443 Less external load 0 0 Less transfer 0 0 0 0 Redistribution 17 32 0 36 66 14 15 Subtotal Duct loads 2969 3765 197 1510 67% 94% 2003 3546 67% 94% 133 1422 Total room load Air required (cfm) 4972 7311 1 329 2932 453 400 30 160 Calculations a roved by ACCA to meet all re uirements of Manual J 8th Ed- -.r WrivI1t-cart Rlght-Suite& Unlversal201212.0.02 RSU11227 2012-Jul-31 08:45:55 nts and Settings4ib6.L1BERTYHEATINGIDesktoplMendoxa\Lotl9.rup Calc = MJ8 Front Door faces: Page 6 wrightsort- Right,J® Worksheet Entire House True Air Mechanical Job: Avenida Mendoza Lot 19 Date: Jul 27, 2012 By: True Air Mechanical Plan: Lot 19 1 Room name DINING 2 Exposed well 16.5 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 12.0 x 16.5 ft 5 Room area 198.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ftk'F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S He Cool Gross N/P/S Heat Cool 6 VI/ I�� 12C-Osw 0.091 ne 2.30 3.59 165 125 288 449 2 glazing, dr outr, 0.350 ne 8.85 26.86 40 0 354 1074 V+/ 12C-Osw 0.091 se 2.30 3.59 0 0 0 0 1OD-f 0.420 se 10.63 27.28 0 0 0 0 G Vjl L—G 11 12GOsw 0.091 sw 2.30 3.59 0 0 0 0 2 glazing, dr outr, 0.350 sw 8.85 29.01 0 0 0 0 V)/ �--G 12C-0sw 0.091 nw 2.30 3.59 0 0 0 0 2 glazing, dr outr, 0.350 nw 8.85 26.86 0 0 0 0 C 16D-30td 0.032 0.81 1.53 198 198 160 304 F 22A-tpl 0.989 25.02 0.00 198 17 413 0 61 c) AED excursion $1 Envelope loss/gain 1215 1745 12 a) Infiltration 352 216 b) Room ventilation 0 0 13 Internal gains: Occupants (8 230 0 0 Applianceslother 0 Subtotal (lines 6 to 13) 1567 1961 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1567 1961 15 I Duct loads 67% 94% 1057 1847 Total room load 2624I 3808 Air required (cfm) I I 239 2081J Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wrighisarft 2012-Jul-31 08:45:55 Right -Su ite®Universal 2012 12.0.02 R S U 1 1227 Page 7 nts and SettingsVib6.LIBERTYHEATINGIDesktop%Mendoza\Lot19.rup Cale = MJ8 Front Doorfaces: Job #: Avenida Mendoza Lot 19 Performed by True Air Mechanical for: Avenida Mendoza 3194 Airport Loop Dr., *C-2 Costa Mesa, Ca 92626 Level 1 True Air Mechanical Scale: 1 : 101 Page 1 Rght-Suite® Universal2012 12.0.02 RSU11227 2012-Jul-31 08:46:19 ... EATING\Desktop\Mendoza\Lot19. r. Wri htsoft. Duct System Summary Job: Avenida Mendoza Lot 19 9 Date: Jul 27, 2012 Entire House By: True Air Mechanical True Air Mechanical Plan: Lot 19 Y _ Pro.- Information - For: Avenida Mendoza, Canaday 3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.38 / 0.12 in H2O 0.38 / 0.12 in H2O Lowest friction rate 0.320 in/100ft 0.320 in/100ft Actual air flow 1767 cfm 1767 cfm Total effective length (TEL) 156 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 h 749 68 56 0.376 5.0 Ox 0 VIFx 17.3 85.0 st7 BDR3 c 3574 177 195 0.449 8.0 Ox 0 VIFx 15.7 70.0 st4 DINING h 2624 239 208 0.456 9.0 Ox 0 VIFx 14.4 70.0 st3 GREAT RM h 2486 227 200 0.458 8.0 Ox 0 VIFx 14.1 70.0 st2 GREAT RM-A h 2486 227 200 0.345 8.0 Ox 0 VIFx 26.6 85.0 st6 KIT c 2932 30 160 0.489 7.0 Ox 0 VIFx 8.6 70.0 st3 LAU c 195 8 11 0.336 5.0 Ox 0 VIFx 29.7 85.0 st6 MBA h 2689 245 175 0.327 9.0 Ox 0 VIFx 27.5 90.0 st5 MBR c 4925 259 269 0.426 9.0 Ox 0 VIFx 20.2 70.0 SO MBR2 c 4515 201 247 0.345 9.0 Ox0 VIFx 26.6 85.0 st7 `Mc h 941 86 45 0.320 6.0 0x 0 VIFx 30.2 90.0 st5 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st7 Peak AVF 269 303 0.345 556 10.0 0 x 0 VinlFlx st4 SW Peak AVF 446 498 0.345 635 12.0 0 x 0 VinlFlx st6 Peak AVF 235 210 0.336 532 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 462 410 0.336 588 12.0 0 x 0 VinlFlx st3 Peak AVF 269 368 0.456 469 12.0 0 x 0 VinlFlx st5 Peak AVF 331 221 0.320 607 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 590 490 0.320 552 14.0 0 x 0 VinlFlx Bold/Italic values have been manually overridden Wri heft. 2012-Jul-3108:45:57 9 Right-Suita®Universal 2012 12.0.02 RSU11227 Page 1 nts and Settings\lib6.LIBERTYHEATING\Desktop\Mendoza\Lotlg.rup Calc = MJ8 Front Door faces: Jame rb1 Grill Size (in) Ox0 Htg (cfm) 1767 Clg (cfm) 1767 TEL (ft) 36.0 Design FIR 0.320 Veloc (fpm) 810' Diam (in) 20.0 H x W (in) Ox 0 Stud/Joist Opening (in) Duct Matl VIFx Trunk Boldgtalic values have been manually overridden C wri htSO 2012-Jul-3108:45:57 �^.�C� 9 Right-Suite®Universa12012 12.0.02 RSU11227 AM ...nts and SettingsVib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces: Page 2