12-0886 (SFD)I
BOX 1504
78-495 CALLE TAMPICO
LA .QUINTA, CALIFORNIA 92253
Tiht
"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 12-00000886
Property Address: 52070 AVENIDA MENDOZA
APN: 773-2337004-19 -000000-
Application description: DWELLING - SINGLE FAMILY DETACHED
Property Zoning: COVE RESIDENTIAL
Application valuation: 119135
Applicant: Architect or Engineer:
CWT [.^AWLI" 90PAZ
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professional Code, and my License is in full force and effect.
License Class: B. is 14
Date: (! Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractorls).licensed
pursuant to the Contractors' State License Law.).
1 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
CT PROPERTIES, INC.
C/O CHRIS CANADAY
3194 AIRPORT LOOP DRIVE #C2
COSTA MESA, CA 92626
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/23/12
Contractor: Dp
CT PROPERTIES INC
3194 AIRPORT LOOP DRIVE, #
COSTA MESA, CA 92626 JANtO 3(714)327-1710
Lia. No.: 930614
-------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 167794
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should come subject t:g the workers' compensation provisions of Section
J Q 3700 of the Labor Cod o. t omply with those provisions.
Date: / v �-'Applicant:
1
WARNING: FAILURE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building constru tion, d hereby authorize representatives
of this county to enter upon the above-mentioned property rposes.
Date: / /41 /JSignature (Applicant or Agent):
LQPERMIT
Application Number . . . . . 12-00000886
------ Structure Information 1,817SF DWELLING/VB/RES-3/CL-A/13D
[ENG] -----
Other struct info . .
. . . CODE EDITION 2010
# BEDROOMS
3.00
FIRE SPRINKLERS 13D
GARAGE SQ FTG
427.00
PATIO SQ FTG
227.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE 1817.00
Permit . . .
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
709.50 Plan Check Fee
461.18
Issue Date . . . .
Valuation . . . .
119135
Expiration Date
4/21/13
Qty --•Unit"Charge
Per
Extension
BASE FEE
639.50
20.00 3.5000
-----------------------------------------7----------------------------------
THOU BLDG 100,001-500,000
70.00
Permit . . .
ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
102.14 Plan Check Fee
25.54
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
4/21/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1817.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
63.60
427.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
8.54
1.00 15.0000
----------------------------------------------------------------------------
EA ELEC TEMPORARY POWER POLE
15.00
Permit . . .
GRADING PERMIT
Additional desc . .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date 4/21/13
Qty Unit Charge Per Extension
BASE FEE 15.00
----------------------------------------------------------------------------
Permit . . . MECHANICAL
Additional desc . .
Permit Fee . . . . 71.00 Plan Check Fee 17.75
Application Number .
. . . . 12-00000886
Permit . . . . . . MECHANICAL
Issue Date . . . .
Valuation . . . .
0
Expiration Date
4/21/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT
4.50
1.00 16.5000
EA MECH B/C >3-15HP/>100K-500KBTU
16.50
3.00 6.5000
EA MECH VENT FAN
19.50
1.00 6.5000
----------------------------------------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit . . .
PLUMBING
Additional desc . .
Permit Fee . . . .
153.00 Plan Check Fee
38.25
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
4/21/13
Qty Unit Charge
Per
Extension
BASE FEE
15.00
14.00 6.0000
EA PLB FIXTURE
84.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
1.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
3.00
2.00 .7500
EA PLB GAS PIPE >=5
1.50
1.00 15.0000
EA PLB GAS METER
15.00
----------------------------------------------------------------------------
Special Notes and Comments
1,817SF DWELLING/VB/RES-3/CLASS-A/13D
[ENGINEERED] THIS PERMIT DOES NOT
INCLUDE BLOCK WALLS, POOL OR SPA, OR
DRIVE WAY APPROACH. 2010 CALIFORNIA
BUILDING CODES.
October 23, 2012 9:36:10
AM AORTEGA
-------=--------------------------------------------------------------------
Other Fees . . . . .
. . . . ART IN PUBLIC PLACES -RES
20.00
BLDG STDS ADMIN (SB1473)
5.00
DIF COMMUNITY CENTERS -RES
104.00
DIF CIVIC CENTER - RES
1089.00
ENERGY REVIEW FEE
46.12
DIF FIRE PROTECTION -RES
612.00
GRADING PLAN CHECK FEE
15.00
DIF LIBRARIES - RES
334.00
MULTI -SPECIES (MSHCP). FEE
521.00
DIF PARK MAINT FAC - RES
51.00
LQPERMIT
. •OL
LQPERMIT
Application Number . . . . 12-00000886
----------------------------------------------------------------------------
Other Fees . . . . . . . . . DIF PARKS/REC - RES 1773.00
COVE PRECISE PLAN FEE 100.00
STRONG MOTION (SMI) - RES 11.91
DIF STREET MAINT FAC -RES 158.00
DIF TRANSPORTATION - RES 3592.00
Fee summary Charged
Permit Fee Total 1050.64
Plan Check Total 542.72
Other Fee Total 8432.03
Grand Total, 10025.39
Paid Credited Due
.00 .00 1050.64
250.00 .00 292.72
.00 .00 8432.03
250.00 .00 9775.39
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALI M ESA
CANYON LAKE
COACHELLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
PALM DESERT
FERRIS
RANCHO MIRAGE
RUBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
BOB BUSTER
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
RIVERSIDE COUNTY FIWEPARTMENT
IN COOPERATION WITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886
• Fax (760) 863-7072
www.rvcfire.org
September 11, 2012
Shasta Fire
72-120 Northshore Street
Thousand Palms, CA 92276
Re: Residential Fire Sprinkler Plan Review
LQ -12 -RS -048 52-070 Avenida Mendoza La Quinta, CA
The sprinkler plans you submitted for the above referenced project have been reviewed by
Riverside County Fire Department Planning & Engineering personnel and are approved with
the following conditions:
A minimum of three spare fire sprinklers of each type and temperature rating along with a
sprinkler wrench should be located in a spare head cabinet at the system riser or other
approved location.
Permanently marked identification signs shall be attached to all control valves
The completed Contractor's Material and Test Certificate for Aboveground Piping shall be
provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure
10.10.1 NFPA13.
A warning sign, with minimum '/ inch letters, shall be affixed adjacent to the main shutoff valve
and shall state the following:
WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a
fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler
system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system
without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign.
The following inspections/tests are required to be witnessed by the Fire Department Planning
Division staff:
(a) Overhead Rough and Hydro static test: All piping shall be visible and
pumped at normal operating pressure.
(b) Final inspection.
The Fire Department job card, approved plans and conditions letter must be at the job site or
NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire
Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection
date.
All questions regarding the meaning of these conditions should be referred to the Fire
Department Planning & Engineering staff at (760) 863-8886.
Applicant/installer shall be responsible to contact the Fire Departme to sched a insp ion.
Sincerely,
Jason tubble
Fire Safety Specialist
Building
Address
Owner
7-
c6ttfl at 4
e-YCily sic
CdS�t /i'i,-s� �� Tel. 5.2 7/710
Contrac f
G !
BUILDING: TYPE CONST. 6 OCC. GRP. 3/
A.P. Number . 7 3 a 3
Legal Description /_o r 7 �LK �J�, `/�� "��lT//
Project Description S �►Q �, r' r► r 647 GAc
cily CoS Z�a G 24=k7/,T.3.27/7/L7
�S
S Ft.
Size 16317
No. No. Dw. f&
Stories Units
State Lic. /-� 7
Classif. `f 7 (� �p�
Arch Engr. E� �� �C
/
New Add ElAlter
❑ Repair El Demolition ElDesig
Address Tel.
/ 600 E. IG {!r S /- 4)-,, ¢i3
-
City
S"4'74IL 4.1 �
Zi
.2701
State
Lic. # 5 3.Y
LICENSED CONTRACTOR'S DECLARATION
hereby affirm the it nse u er ovr s of Chapter 9 (commenc ng with Section
711) of ➢lvlsion he sin f' s Code, anti my license is In u for a and
effect.
SIGNATURE ATE
WNER-BUILDER DECLARATION
Estimated Valuation�j
Q
I hereby affirm that I am ex�mp[ from the Contractor's License Law for the following
reason: (sac. 103r,5, ausinr3ss and Protessions Cade: Any clly or county winch requires a
permit to construct alter; improve, demolish, arrepairanysiruature, priers its r'sstranae also
requires the applicant for such perr'ft fo rla a siggnrted statement that he is licensed pursuant to
fhu povisions of the Conlrscta+'s License Law, Chapter 9 (commencing with Suction 7000) of
Division 3 of the Business End Professfons Code, or fhet Ire is exempt fhematram, and the basis
(or the alleged exrumrpnon. Aa'y vlora' "ol5octien 7'03'.' fry any applicant fora permirsubjecfs
the applic:nr to : croft pan:Ity ether mare than live hundred dollars 1.500).
PERMIT
AMOUNT
Plan Chk. Dep.
�7, 0
Plan Chk. Bal.
1] I, as owner of the prvperiy, or my employees with wages as their sole compensation, will do
the work, and the structure Is not intended or offered for sale. (Sec. 7044, Business and Ptofes-
Sion$ Code: The Corfhacfor's Llconse Law does not apply to an owner of property who builds
or impraves fharsafr and wtro doss such work himself or through Iris own amplrryy99es, provfdad
that such improvumoil era not infended or offered for sate. If, hdwavet; the hot ding or lm-
provament Is sold wlthffr one year of campletfnn, the owner -builder will have (ha burden of
Prow that ha did hat bu8d orimpmve for the purpose of sale).
❑ I, as owner of the property, am exclusively con"cting with licensed contractors to construct
the project (Sac. 7044. Business and Professions Code: The Conlractor's Ucense Lawdoes
not apply 10 an owner of property who builds or Improves thereon, and who contracts for such
projects with a canlractor(s) Ucensedpursuanf to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
ConSt.
Mech.
Electrical
PIUmblftg•'.
S.M.I.
Grading
Driveway Enc.
�
Date Owner
Infrastructure
i
WORKER'S COMPENSATION DECLARATION
2z
1 hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
f r�
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
'
V.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
Is' section need not be completed if the permit is for one hundred dollars ($100) valuation
nr less).
1 certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to became subject to Workers' Compensation Laws of
California.
TOTAL
} Olin'
REMARKS
r
lry� M
-_ -
—
Date Owner
NOTICE TO APPLICAfdT. !!, after making this Certfllcate of Exemption you should become
subfecf to the Workers' Compensation provisions of the Labor Code, you must forthwilh
comply with such provisions or this permit shall be deemed revoked.
ZONE: By:
Minimum Setback Distances:
CONSTRUCTION LENDING AGENCY
Front Setback from Center Line
I herebyy atflrm that there Is a construction lending agency for the performance of the work
for which tt is permit is issued. (Sec. 3097, Civil Code.)
Rear Setback from Rear Prop. Line
Lender's Name
Side Street Setback from Center Line
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify tho I have read this application and state that the above Inforrrravon is correct.
I agree to comply with all city and county ordinances and state laws relating to huilding
construction, and hereby authorize representaflves of this city to enter the above -mentioned
properly for Inspecttan purposes.
FINAL DATE
Issued by:
Side Setback from Property Line
INSPECTOR
Date Permit •
Signature of applicant Date
Mailing Address
Validated by:
City, State, Zip
Validation
WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE
7'1
Date 1/18/13
No. 31530
Owner CT Properties
Address
City Zip
Tract #
Type Single Family Residence
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8615
APN #
Jurisdiction
Permit #
No. of Units
�WDt'
q-
ro
k' BERMUDA DUNES
RANCHO MIRAGE t4)
r� INDIAN WELLS �+
di- 1 PALM DESERT y
V' LA 4UFNTA
%INDIO y,
0
773-233-004
La Quinta
1
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 52070 Avenida Mendoza 1817 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments Certs 31530 & 31 used for cc totaling $11,628.80.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.20 X 1,817 S.F. or $5,814.40 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Citizens Business Bank - Robert Walker Check No. 239545
Bank Name/Recipient of Certificate Telephone 760-275-8731
Funding Residential
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exempted by on Gllvrey Payment Recd
$5,814.40 'aver/Under
Signature
NOTICE: Pursuant 'to Government Code SeLtrbn 66020(d)(1�. this will serve to notify you that the 90-day approval period in which you may protest the fees
or other payment identified above will begin to run from the dlit on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
Tjhf 4 4 a"
To: Greg Butler, Building & Safety Manager
From:
Planning
BUILDING & SAFETY DEPARTMENT
(760)777-7012
FAX (760) 777-7011
o^
To CDD: q — / .�,
I&L4 O� q_a�-ice
AT)
Building Permit Release
(This is an approval to issue a Building Permit)
The Community Development Department has reviewed the following project:
Description: el-)
Address or general location: Jam' -;2 O 7 O
APN and or legal description:
The Community Development Department finds that:
❑ ...issuance of this Building Permit does not require Community Development
Department approval.
❑ ... issuance of this Building Permit is approved by the Community Development
Department.
CO vr"cG �1- L ti.S 1/V-k2.Ae-( j S e .� `t��r. Me —O
ZY IJ y
� III
Pinrer signature Date
KAY'S GRN SHEET.doc
7/15/2004
dl&41131
t( 5A
�-Pcel v
SEA
1, cnning DePOt"ir
U&M
T4hf 4 Q
MEMORANDUM
TO: Building and Safety Department
FROM: 6Eric Ceja, Assistant Planner
DATE: 8/9/12
RE: 52-070/52-090 AVENIDA MENDOZA
CT PROPERTIES, INC.
The Planning Department has reviewed the building plans for the above
mentioned properties and has the following comments:
1. The "pop" out features for the proposed fireplace and media niche
encroach into the five (5) foot side yard setback by one and a half feet
(1.5'). The applicant shall correct the plans to maintain the five (5) foot
side yard setback on both properties.
2. The architecture for the buildings is acceptable as it incorporate various
architectural elements not common to surrounding homes.
If you have any questions, please contact me at X7125.
Plan Check Memo (52-070, 090 Avenida Mendoza)
DOC # 12-0263128
06/07/2012 12:24 PM Fees: $18.00
RECORDING RE")UESTED BY: Page 1 of 2 Doc T Tax Paid
First American Title Ins. Co. Recorded in Official Records
County of Riverside
AND WHEN RECORDED MAIL TO: Larry W. Ward
CT Properties, Inc. Assessor, County Clerk & Recorder
Chris Canaday
3194 Airport Loop Drive #C2
Costa Mesa, CA 92626 —This document was electronically submitted
to the County of Riverside for recording'
Receipted by: YSEGURA
• -�� THIS SPACE FOR RECORDER'S USE ONLY:
Title Order No.: 4054380 Escrow No.: 004833-KG
GRANT DEED
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX is $67.10
[X] computed on full value of property conveyed, or
[ J computed on full value less value of liens oar encumbrances remaining at time of sale.
[ J Unincorporated area [Xj City of LA q vm
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Lillian R. Zelisse, a Married Woman, as her sole and separate property
hereby GRANT(s) to:
CT Properties, Inc., a California Corporation
the real property in the City of La Quinta, County of Riverside, State of California, described as:
LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF
Also Known as: Vacant Land - APN 773-233-004-5, La Quinta, CA
AP#: 773-233-004-3
Tra-1Q2o -U1
DATED May 22, 2012
STATE OF CAUFO r
COUN OF
On _ I Z
before me,
A+ Nyta Pubtic in �qd for said State personally appeared
trl � l 1 ct n I�L —) .P k i 5 SP
illi In R. Zelisse
who proved to me on the basis of satisfactory evidence to be
the person(s) whose name(s) is/W6 subscribed to the within C. BLAUS€R
instrument and acknowledged to me that lie/shehhey- _ Commission # 1822306
executed the same in hislherlttw-if authorized capacity(ies), Notary Public - California i
and that by hWher/their signature(s) on the instrument the Orange County
person(s), or the entity upon behalf of which the person(s) M Comm, Expires Noy 11, 2012
acted, executed the instrument.
I certify under PERALTY OF PERJURY under the laws of the State
of Callfomia that the oregoing paragraph is true and correct.
WITNESS my hyid #d oliicia
Signature --- / " (Seal)
MAIL TAX STATEMENTS TO PARTY SHOWN BELOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE:
EXHIBIT "A"
Real property in the City of Riverside, County of Riverside, State of California, described as
Follows:
LOTS 18 AND 19 IN BLOCK 94 OF UNIT NO. 11, SANTA CARMALITA AT VALE LA QUINTA, AS
SHOWN BY MAP ON FILE IN BOOK 18 PAGE 75 OF MAPS, RECORDS OF RIVERSIDE COUNTY,
CALIFORNIA.
APN: 773-233-004-3 and 773-233-005-4
Title 24 Energy Report
52-070 AVENIDA MENDOZA
The Cove, Plan 1BR
La Quinta
Climate Zone #15
2008 Building Energy Efficiency Stan
BEG Project No.: 12053
RE ,:.IVE 0
AUG 0 8 2012
BY:
CT Properties, Inc.
!"NIP
CITY OF (-A QUINITA
BUILDING & SAFETY DEPT.
APPR
FOR CONSTRUCTION
DATE 10 W1- BY
Heritage Energy Group, LLC
July 26, 2012
Title 24 Energy Calculations
Tel: (949) 789-7221 / Fax: (949) 789-7222
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 1
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
Project Address 52 t d d
-070 A 'M ******
�
La Quinta *v8.1*
Documentation Author... Rudy Sains ****** Building Permit #
Heritage Energy Group, LLC
470 Wald Plan Check / Date
Irvine, CA 92618
(949) 789-7221 Field Check/ Date
Climate Zone........... 15
Compliance Method.,.... MICROPAS8 v8.1 for 2008 CEC Standards (r03)
MICROPAS8 v8.1 File-12053P1B Wth-CTZ15S08
User#-MP0940 User -Heritage Energy Group, LL Run-
MICROPAS8 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/sf-yr)
Design
Design
Margin
Improvement
Space Heating..........
3.38
3.93
-0.55
-16.3o
Space Cooling..........
77.01
63.86
13.15
17.10
Ventilation Fans.......
1.06
1.06
0.00
0.0%
Water Heating..........
17.26
12.03
5.23
30.3%
Total
98.71
80.88
17.83
18.10
*** Building
complies with
Computer
Performance ***
*** HERS Verification Required for
Compliance ***
r
.,,it .6
GENERAL INFORMATION
HERS Verification..........
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Natural Gas at Site .......
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U-factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Required
1817 sf
Single Family Detached
New
Yes
Front Facing 270 deg (W)
1
1
FullYear
Slab On Grade
1
18170 cf
1817 sf
16.7 % of floor area
0.33 Btu/hr-sf-F
0.22
10 ft
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
Zone Type
Residence
BUILDING ZONE INFORMATION
Floor # of # of Cond- Thermo -
Area Volume Dwell Peop- it- stat
(sf) (cf) Units le ioned Type
1817 18170 1.00 6.0 Yes Setback
ATTIC AND ROOF DETAILS
Vent Vent Verified
Height Area Leakage or
(ft) (sf) Housewrap
2.0 Standard 3 SLA
Frame R-
R-
Roof
Roof Re- Emiss-
Frame
Spac- Value
Value Vent
Mass
Rise flect- ivity
Depth
ing Above
Below Area Vent
Roof Type
(lb/sqft)
ance
(in.)
(in.) Deck
Deck Ratio High
Tile
Heavy
4:12 0.10 0.85
3.5
24 oc 0.00
0.00 1/300 0.00
OPAQUE SURFACES
U-
Sheath-
Solar Appendix
Frame
Area fact-
Cavity ing
Act
Gains JA4
Location/
Surface
Type
(sf) or
R-val R-val
Azm Tilt
Reference Comments
1
Wall
Wood
302 0.072
13 4
90
90 Yes 4.3.1
C3
2
Wall
Wood
429 0.072
13 4
0
90 Yes 4.3.1
C3
3
Wall
Wood
134 0.072
13 4
270
90 Yes 4.3.1
C3
4
Wall
Wood
402 0.072
13 4
180
90 Yes 4.3.1
C3
5
Wall
Wood
210 0.102
13 0
270
90 No 4.3.1
A3
6
AtticRad
Wood
1817 0.031
30 0
n/a
0 Yes 4.2.1
A20
7
Door
Wood
24 0.500
0 0
270
90 Yes 4.5.1
A4
8
Door
Wood
21 0.500
0 0
270
90 No 4.5.1
A4
PERIMETER
LOSSES
Appendix
Length
F2
Insul
Solar
JA4 Location/
Surface
(ft)
Factor
R-val
Gains
Reference Comments
9
S1abEdge
178
0.730
R-0/Oin
No
4.4.7 Al Standard Slab Edge
Orientation
1 Door
Back
(E)
2 Wind
Back
(E)
3 Wind
Back
(E)
4 Wind
Left
(N)
5 Wind
Left
(N).
6 Wind
Left
(N)
7 Door
Front
(W)
FENESTRATION SURFACES
Exterior
Area U- Act Shade
(sf) factor SHGC Azm Tilt Type Location/Comments
48.0 0.350 0.220 90 90 Standard 1/Vinyl Frame/S.G.D./Low
30.0 0.340 0.220 90 90 Standard 2/Vinyl Frame/Operable/L
20.0 0.340 0.220 90 90 Standard 3/Vinyl Frame/Operable/L
25.0 0.340 0.220 0 90 Standard 4/Vinyl Frame/Operable/L
6.0 0.340 0.220 0 90 Standard 5/Vinyl Frame/Operable/L
30.0 0.340 0.220 0 90 Standard 6/Vinyl Frame/Operable/L
56.0 0.270 0.210 270 90 Standard 7/French Door low-e
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 3
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
Orientation
8 Door Right (S)
9 Wind Right (S)
FENESTRATION SURFACES
Exterior
Area U- Act Shade
(sf) factor SHGC Azm Tilt Type Location/Comments
48.0 0.350 0.220 180 90 Standard 8/Vinyl Frame/S.G.D./Low
40.0 0.340 0.220 180 90 Standard 9/Vinyl Frame/Operable/L
OVERHANGS
Window— erhan
Area Left Right
Surface (sf) Width Height Depth Height Extension Extension
1 Door 48.0 n/a 8 13 0 n/a n/a
8 Door 48.0 n/a 8 12 0 n/a n/a
SLAB SURFACES
Area
Slab Type (sf)
Standard Slab 1817
HVAC SYSTEMS
System Minimum
Type Efficiency
Furnace
ACSplit
Verified
Verified Verified Verified Verified Maximum
Refrig Charge Adequate Fan Watt Cooling
EER or CID Airflow Draw Capacity
0.800 AFUE n/a n/a n/a n/a n/a
14.00 SEER 12 Yes No No No
HVAC SIZING
Verified
Total
Sensible
Design
Maximum
Heating
Cooling
Cooling
Cooling
System
Load
Load
Capacity
Capacity
Type
(Btu/hr)
(Btu/hr)
(Btu/hr)
(Btu/hr)
Furnace
27728
n/a
n/a
n/a
ACSplit
n/a
21438
26604
n/a
Sizing
Location............
LA QUINTA
Winter
Outside
Design......
26 F
Winter
Inside Design.......
70 F
Summer
Outside
Design......
111 F
Summer
Inside Design.......
75 F
Summer
Range ...............
34 F
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
DUCT SYSTEMS
Verified Verified Verified
System
Duct
Duct
Duct
Surface
Buried
Type
Location
R-value
Leakage
Area
Ducts
Furnace
Attic
R-8
Yes
No
No
ACSplit
Attic
R-8
Yes
No
No
Tank Type
INFILTRATION TESTING DETAILS
Blower Door Blower Door
Leakage Target Leakage Minimum
(CFM50h/SLA) (CFM50h/SLA)
1427 / 3.0 714 / 1.5
FAN SYSTEMS
System Type
Flow Power
(cfm) (W/cfm)
Standard 63.17 .25
WATER HEATING SYSTEMS
Number Tank External
Heater in Energy Size Insulation
Type Distribution Type System Factor (gal) R-value
1 SmallTankless Gas StandardNoInsul 1 0.82 n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a Radiant Barrier.
This building incorporates a non-standard Water Heating System.
HERS REQUIRED VERIFICATION
R-n/a
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-4R installation certificate. ***
This building incorporates HERS verified High Quality Insulation Installation.
This building incorporates HERS verified Building Envelope Sealing.
Target and Minimum CFM values measured at 50 pascals are shown in
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 5
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
HERS REQUIRED VERIFICATION
INFILTRATION TESTING DETAILS above. If the measured CFM50h is above
the target, then corrective action must be taken to reduce the
infiltration and then retest. Alternatively, the compliance
calculations could be redone without infiltration testing.
This building incorporates a HERS verified Improved Refrigerant Charge test
or the installation of a HERS verified Charge Indicator Display (CID). If a
cooling system is not installed, then HERS verification is not necessary.
This building incorporates HERS verified High Energy Efficiency Ratio (EER).
This building incorporates HERS verified Duct Leakage. Target leakage is
calculated and documented on the CF-4R. If the measured CFM is above the
target, then corrective action must be taken to reduce the duct leakage and
then must be retested. Alternatively, the compliance calculations could be
redone without duct testing. If ducts are not installed, then HERS
verification is not necessary.
REMARKS
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: Ca10ERTS, Inc
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 6
Project Title.......... Plan 1B Rev - Lot 19 Date..07/26/12 16:23:26
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name....
Name....
Rudy Sains
Company.
CT Properties, Inc.
Company.
Heritage Energy Group, LLC
Address.
3194 Airport Loop Drive
Address.
470 Wald
Costa Mesa, CA
Irvine, CA 92618
Phone...
714-327-1710
Phone...
(949) 789-7221
License.
Signed..
Name....
Title...
Agency..
Phone...
Signed..
ENFORCEMENT AGENCY
te)
(date
Signed..
Electronically Signed at CalCERTS.com by Laurie Oard (CT Properties, Inc.) 7/26/2012
(date)
Electronically Filed by Rudy Sains and Authenticated at CalCERTS.com - 7/26/2012
Reg: 212-N0035104C-000000000-0000 Registration Date/Time: 2012/07/02 17:19:28 HERS Provider: CalCERTS, Inc
-Mandatory Measures Summary MF-IR
Residential (Pase 1 of 3)
Site Address: Enforcement Agency: Date:
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,
regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1R,
CF-IR-ADD, or CF-1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures
Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum
componentperformance specifications whether they are shown elsewhere in the documents or in this summary. Submit all
a licable sections of the MF-IR Form with plans.
DESCRIPTION
Building Envelope Measures:
§ 116(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient
(SHGC), and infiltration that meets the requirements of § 10-11l(a).
§ 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
§ 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
§ 118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of § 118(i) when the installation of
a Cool Roof is specified on the CF-lR Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U-factor.
§ 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
*§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U-factor:
*§ 150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U-factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-lR Form.
§ 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no
greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150(e)lA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped
with a with a readfly accessible, o erable, and ti ht-fittingdamper and or a combustion -air control device.
§ 150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110-§ 113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission.
§ 113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve,
backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§ 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an
electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters.
§ 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§ 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(r 1
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
§1500)1B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12
external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
§ 1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections
of hot water pipes are insulated per Standards Table 150-B.
§ 1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank
shall be insulated to Table 150-B and Equation 150-A.
§ 1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A.
§ 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§ 1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space.
2008 Residential Compliance Forms August 2009
-Mandatory Measures Summary MF-1R
Residential (Page 2 of 3
Site Address: Enforcement Agency: Date:
1500 j4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Ducts and Fans Measures:
§150(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602,
603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or
enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable
requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings reater than 1/4 inch, the combination of mastic and either mesh or toe shall be used
§150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,
duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts.
Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts.
§ 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape
is used in combination with mastic and draw bands.
§ 150(m)7: Exhaust fan systems have back draft or automatic dampers.
§ 150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§ 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that
can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§ 150(o): All dwelling units shall meet the requirements of ANSFASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in
Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in
Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§ 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;
an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use
electric resistance heating or a pilot light.
§ 114(b)l: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return
lines, or built-up connections for future solar heating
§ 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§ 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§ 150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p).
Residential Lighting Measures:
§150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in
Table 150-C and is not a low efficacy luminaire as specified by § 150(k)2.
§ 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d).
§ 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
§ 150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage
lamp holder; OR shall be rated to consume no more than five watts of power as determined by § 130(d), and shall not contain a medium
screw -base socket.
§ 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of § 150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed Iighting in kitchens shall be highefficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 If or 100 watts for dwelling units larger than 2,500 fig may be exempt
from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (FMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§ I50(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high
efficacy.
2008 Residential Compliance Forms August 2009
Mandatory Measures Summary MF-1R
Residential (Page 3 of 3)
Site Address: Enforcement Agency: Date:
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of § 119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupant sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy luimnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch
that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the
applicable requirements of § 119.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply
with § 150(k)11.
§ 150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or
other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then
2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing
and ceiling.
§ 150(k)13: Luminaires providing outdoor lighting, including ligbting for private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot
shall be high efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual
on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the
following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an
energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be
always on
EXCEPTION 2: Outdoor luminaires used to comply with Exception) to §150(k)13 may be controlled by a temporary override switch
which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six
hours.
EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of
the California Electric Code need not be high efficacy luminaires.
§ 150(k)14: Internally iiluminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five
watts of power as determined according to 130(d).
§ 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in
Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of
Sections 130, 131. 134. and 146
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units
shall be high efficacy luminaires.
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s)
certified to comply with the applicablc requirements of § 119.
2008 Residential Compliance Forms August 2009
RFC
/7
wrightsoft` Load Short Form
Entire House
True Air Mechanical
By_
AUG 0 8 2012
For: Avenida Mendoza, Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
.- j
Htg
Clg Infiltration
Outside db (°F)
45
111 Method Simplified
Inside db (°F)
70
75 Construction quality Semi -tight
Design TD (°F)
25
36 Fireplaces 1 (Average)
Daily range
-
H
Inside humidity (%)
50
50
Moisture difference (gr/Ib)
20
-6
HEATING EQUIPMENT
Make Carrier
Trade CARRIER
Model 58STX110-22"
AHRI ref no. 2000822
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
80 AFUE
105000
Btuh
85000
Btuh
44
°F
1767
cfm
0.091
cfm/Btuh
0.50
in H2O
COOLING EQUIPMENT
Make Carrier
Trade AIRSTAR, TFC, MERIDIAN
Cond CA16NA060*"*A
Coil ASF*6026A28G++D+V or EQUAL
AHRI ref no. 4724581
Efficiency 12.0 EER, 14.5 SEER
Sensible cooling
37100
Btuh
Latent cooling
15900
Btuh
Total cooling
53000
Btuh
Actual air flow
1767
cfm
Air flow factor
0.055
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.96
ROOM NAME
Area
OF)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MBA
108
2689
3204
245
175
MBR
264
2846
4925
259
269
WIC
51
941
831
86
45
BDR3
175
1938
3574
177
195
BA2
63
749
1027
68
56
MBR2
196
2204
4515
201
247
HALL2
54
0
0
0
0
HALL
106
0
0
0
0
LAU
48
93
195
8
11
GREAT RM
328
4972
7311
453
400
KIT
r11 KI Aln
198
dno
329
nBnA
2932
nono
30
nnn
160
nno
VII1 I`IV
AO LVGY JOVO 40t7 GVO
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
+ wright50ft" Right -Suite® Universal 2012 12.0.02 RSU11227
...nls and SettingsVib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc= MJB Front Door faces:
2012-Jul-31 08:45:54
Page 1
Entire House d
1788
19384
32322
1767
1767
Other equip loads
0
0
Equip. @ 1.16 RSM
37558
Latent cooling
1427
-/ Al n
A
AAf n
I
I V I P9LV I UU I vJU•t OUCIOU !IV! I/ V/
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
ti Wrl nt$ai 2012-Jul-3108:45:54
9 Right-Suite®Universal201212.0.02 RSU11227 Page
nts and Settings\lib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJS Front Door faces:
Building Analysis Job: Avenida Mendoza Lot 19
wrightsoft° Date: Jul 27, 2012
Entire House By: True Air Mechanical
True Air Mechanical Plan: Lot 19
Project Information_
For: Avenida Mendoza. Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
]esitlrn Conditir
Location:
Indoor:
Heating
Cooling
La Quinta, CA, US
Indoor temperature (OF)
70
75
Elevation: 476 ft
Design TD (OF)
25
36
Latitude: WN
Relative humidity (%)
50
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
20.1
-5.8
Dry bulb (OF) 45
111
Infiltration:
Dailyrange (OF) -
27 ( H )
Method
Simplified
Wet bulb (°F) -
73
Construction quality
Semi -tight
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Heating -4
Component
Btuh/ft2
Btuh
% of load
Walls
2.3
2401
12.4
Glazing
9.3
1932
10.0
Doors
0
0
0
Ceilings
0.8
1447
7.5
Floors
1.7
3128
16.1
Infiltration
2.1
2666
13.8
Ducts
7809
40.3
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
19384
100.0
-- Cooling
Component
Btuh/ft2
Btuh
% of load
Walls
3.6
3744
11.6
Glazing
27.6
5715
17.7
Doors
0
0
0
Ceilings
1.5
2743
8.5
Floors
0
0
0
Infiltration
1.3
1633
5.1
Ducts
15677
48.5
Ventilation
0
0
Internal gains
2810
8.7
Blower
0
0
Adjustments
0
Total
32322
100.0
Latent Cooling Load =1427 Btuh
Overall U-value = 0.073 Btuh/fF-°F
Data entries checked.
N -N-
2012-Jul-31 08:45:54
111iCfQhtlbt Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1
+ ...nts and SetbngsUibB.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Doorfaces:
Component Constructions
Job: Avenida Mendoza Lot 19
WrlghtsQft°
Entire House
Date: Jul 27, 2012
By: True Air Mechanical
True Air Mechanical
Plan: Lot 19
Project Information
For:
Avenida Mendoza, Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
Design Conditions
Location:
Indoor:
Heating Cooling
La Quinta, CA, US
Indoor temperature (OF)
70 75
Elevation: 476 ft
Design TD (OF)
25 36
Latitude: 34°N
Relative humidity (%)
50 50
Outdoor:
Heating Cooling Moisture difference (gdlb)
20.1 -5.8
Dry bulb (OF)
45 111 Infiltration:
Dailyrange (OF)
- 27 (H ) Method
Simplified
1IUet bulb (°F)
- 73 Construction quality
Semi -tight
Wind speed (mph)
15.0 7.5 Fireplaces
1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
fr Bhfi/fl -°F R'-° F/Btuh BUMP Btuh Btuh/W Btuh
Walls
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 5/8" gypsum board int
fnsh, 2"x4" wood frm
Partitions
(none)
Windows
2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk: 2
glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk
10D-f: 2 glazing, clr outr, air gas, insulated fiberglass frm mat, clr
low-e innr, 1/4" gap, 1/8" thk
Doors
(none)
Ceilings
16D-30td: Attic ceiling, tile, slate, concrete roof mat, r-30 cell ins, 5/8"
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile fir fnsh
ne
315
0.091
13.0
2.30
725
3.59
1131
se
59
0.091
13.0
2.30
136
3.59
212
sw
429
0.091
13.0
2.30
988
3.59
1540
nw
240
0.091
13.0
2.30
553
3.59
862
all
1043
0.091
13.0
2.30
2401
3.59
3744
ne
40
0.350
0
8.85
354
26.9
1074
sw
61
0.350
0
8.85
540
29.0
1770
nw
50
0.350
0
8.85
443
26.9
1343
all
151
0.350
0
8.85
1337
27.7
4187
se
56
0.420
0
10.6
595
27.3
1528
1788 0.032 30.0 0.81 1447 1.53 2743
125 0.989 0 25.0 3128 0 0
1iVii91iftQit' Rig ht-Suite®Universal 2012 12.0.02 RSU11227 2012-Jul-31 08:45:55Page 1
nts and SettingsUib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces:
Project Summary Job: Avenida Mendoza Lot 19
Wrightsoft` Date: Jul 27, 2012
Entire House By: True Air Mechanical
True Air Mechanical Plan: Lot 19
For: Avenida Mendoza, Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
Notes:
Design Information
Weather: La Quinta, CA, US
Winter Design Conditions
Outside db
45
OF
Inside db
70
OF
Design TD
25
OF
Heating Summary
Structure
11575
Btuh
Ducts
7809
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
19384
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Semi -tight
1 (Average)
Heating
Cooling
Area (ft�
1788
1788
Volume (fls)
17878
17878
Air changes/hour
0.33
0.14
Equiv. AVF (cfm)
97
42
Heating Equipment Summary
Make Carrier
Trade CARRIER
Model 58STX110-22*
AHRI ref no. 2000822
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
80 AFUE
105000
Btuh
85000
Btuh
44
OF
1767
cfm
0.091
cfm/Btuh
0.50
in H2O
Summer Design Conditions
Outside db
111 OF
Inside db
75 OF
Design TD
36 OF
Daily range
H
Relative humidity
50 %
Moisture difference
-6 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
16645
Btuh
Ducts
15677
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
1.16
Equipment sensible load
37558
Btuh
Latent Cooling Equipment Load Sizing
Structure
1238
Btuh
Ducts
189
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
1427
Btuh
Equipment total load
38985
Btuh
Req. total capacity at 0.70 SHR
4.5
ton
Cooling Equipment Summary
Make Carrier
Trade AIRSTAR, TFC, MERIDIAN
Cond CA16NA060****A
Coil ASF*6026A28G++D+V or EQUAL
AHRI ref no. 4724581
Efficiency 12.0 EER, 14.5 SEER
Sensible cooling 37100
Btuh
Latent cooling 15900
Btuh
Total cooling 53000
Btuh
Actual air flow 1767
cfm
Air flow factor 0.055
cfm/Btuh
Static pressure 0.50
in H2O
Load sensible heat ratio 0.96
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
1 Wi1 111t15dt 2012-Jul-3108:45:55
` Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1
I9l.C� ...nts and SetBngsVib6.LIBERTYHEATING\Desktop\Mendoza\Lot19.rup Calc = MJ8 Front Door faces:
+- wrightsoft° AED Assessment
Entire House
True Air Mechanical
For: Avenida Mendoza, Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
Design
Conditions
Location:
Indoor:
Heating
Cooling
La Quinta, CA, US
Indoor temperature (T)
70
75
Elevation: 476 ft
Design TD (°F)
25
36
Latitude: 34°N
Relative humidity (%)
50
50
Outdoor: Heating
Cooling
Moisture difference (gNlb)
20.1
-5.8
Dry bulb (°F) 45
111
Infiltration:
Dailyrange (°F) -
27 ( H
)
VVet bu I b (° F) -
73
Wind speed (mph) 15.0
7.5
/ Hourly
Test for Adequate Exposure Diversity
Hourly Glazing Load
I � I-
13 14 15
Hour of Day
/ Average
Maximum hourly glazing load exceeds average by 20.7%.
1
16 17 16 19 3]
AED limtt
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
Wrl htt$dW 2012-Jul-3108:45:55
g Right -Suite® Universal 2012 12.0.02 RSU11227 Page 1
...nts and SettingsUib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces:
+ wrightsoft• Right-M Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
1
Room name
Entire House
MBA
2
Exposed wall
125.0 ft
20.0 ft
3
Room height
10.0 ft d
10.0 ft heat/cool
4
5
Room dimensions
Room area
1787.8 ft'
1.0 x 107.8 ft
107.8 ft'
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
I
Area (ft')
Load
number
(Btuh/ft;"F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
I (Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
y/
G
12C-Osw
0.091
ne
2.30
3.59i
355
315
725
1131
0
0
0
0
2 glazing, clr outr,
0.350
ne
8.85
26.86
40
0
354
1074
0
0
0
0
V+/
I—'
12C-Osw
0.091
se
2.30
3.59
115
59
136
212
0
0
0
0
11
10D-f
12C-0sw
0.420
0.091
se
sw
10.63
2.30
27.28
3.59
56
490
0
429
595
988
1528
1540
0
110
0
110
0
253
0
395
Vj/
2 glazing, dr outr,
0.350
sw
8.85
29.01
61
0
540
1770
0
0
0
0
y/
12C-Osw
0.091
nw
2.30
3.59
290
240
553
862
90
70
161
251
2 glazing, clr outr,
0.350
nw
8.85
26.86
50
0
443
1343
20
0
177
537
—G
C
16D•30td
0.032
0.81
1.53
1788
1788
1447
2743
108
108
87
165
F
22A-tpl
0.989
25.02
0.00
1788
125
3128
0
108
20
500
0
61
c) AED excursion
0
140
Envelope loss/gain
8909
12202
1179
1388
12
a) Infiltration
2666
1633
427
261
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
7
1610
0
0
Appliances/other
1200
0
Subtotal (lines 6 to 13)
11575
16645
1606
1650
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
11575
16645
1606
1650
15
Duct loads
67 %
94%
7809
15677
67%
94%
1083
1554
Total room load
19364
32322
2689
3204
Air required (cfm)
17671
17671
245
175
Calculations approved bx ACCA to meet all re uirements of Manual J 8th Ed.
wri�istsof# 2012-Jul-3108:45:55
Right -Suite 9 Universal 2012 12.0.02 RSU11227 Page 1
nts and SettingsUlb6.LIBERTYHEATING10esktopWend ozalLotl9.rup Calc = MJ8 Front Doorfaces:
+ wrightsoft• Right-M Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
1
Room name
MBR
WIC
2
Exposed wall
18.5 it
7.5 ft
3
Room height
10.0 it heat/cool
10.0 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 263.8 ft
263.8 ft'
1.0 x 51.3 ft
51.3 ft2
Ty
Construction
U-value
Or
HTM
Area (fN)
j Load
I Area (ft')
Load
number
(Btuh/ft;°F)
(Btuh/f l2)
or perimeter (ft)
I (Btuh)
or perimeter (ft)
I (Btuh)
Heat
I Cool
j Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Vp/
G
12C-0sw
0.091
ne
2.30
3.59
0
0
0
0
0
0
0
0
2 glazing, Gr outr,
0.350
ne
8.85
26.86
0
0
0
0
0
0
0
0
V/1
12C-Osw
0.091
se
2.30
3.59
0
0
0
0
0
0
0
0
1OD-f
0.420
se
10.63
27.28
0
0
0
0
0
0
0
0
G
Vj/
I—(
11
12C-Osw
0.091
sw
2.30
3.59
0
0
0
0
75
75
173
269
2 glazing, dr outr,
0 350
sw
8.85
29.01
0
0
0
0
0
0
0
0
V+l
12C-0sw
0.091
nw
2.30
3.59
185
155
357
556
0
0
0
0
2 glazing, clr outr,
0.350
nw
8.85
26.86
30
0
266
806
0
0
0
0
—G
C
16D-30td
0.032
0.81
1.53
264
264
214
405
51
51
41
79
F
22A-tpl
0.989
25.02
0.00
264
19
463
0
51
8
188
0
6
c) AED excursion
581
18
Envelope loss/gain
1299
1824
402
330
12
a) Infiltration
395
242
160
98
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1694
2526
562
428
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
10
0
0
14
Subtotal
1699
2536
562
428
15
Duct loads
67%
94%
1146
2389
67%
94%
379
403
Total room load
2846
4925
941
831
Air required (cfm)
259
269
I
86
45
Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed
WrirgFtrts4t 2012-Jul-31 08:45:55
Right -Suited Universa1201212.0.02 RSU11227 Paget
nts and SetlingslNMUBERTYHEAT INGIDesktoplMendozMLot19.rup Calc = MJ8 Front Doorfaces:
* wrightsoft-
Right-M Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
1
Room name
BDR3
BA2
2
Exposed wall
12.0 ft
5.0 ft
3
Room height
10.0 ft heat/cool
10.0 ft heat/cool
4
5
Room dimensions
Room area
1.0 x 175.0 ft
175.0 ft'
12.5 x 5.0 ft
62.5 ft'
Ty
1
Construction
number
U-value
(Btuh/ft;.F)
Or
HTM
(Btuh/ft2
i Area (ft')
I or perimeter ft ()
i Load
(Btuh)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
I Cool
Gross
N/P/S
Heat
Cool
6
Vt/
�{
12C-Osw
2 glazing, olr outr,
12C-Osw
0.091
0.350
0.091
ne
ne
se
2.30
8.85
2.30
3.59
26.86
3.59
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
10D-f
0.420
0.091
se
sw
10.63
2.30
27.28
3.59
0
120
0
95
0
219
0
341
0
50
0
44
0
101
0
158
V"12C-Osw
2 glazing, clr outr,
12C-Osw
2 glazing, clr outr,
0.350
0.091
0.350
sw
nw
nw
8.85
2.30
8.85
29.01
3.59
26.86
25
0
0
0
0
0
221
0
0
725
0
0
6
0
0
0
0
0
53
0
0
174
0
0
V)/
t-G
C
F
I
16D-30td
22A-tpl
0.032
0.989
0.81
25.02
1.53
0.00
175
175
175
12
142
300
269
0
63
63
63
5
51
125
96
0
6 I
c) AED excursion
1841
1
117
Envelope loss/gain
882
1419
1
1 330
445
12
a) Infiltration
256
157
107
65
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
1
230
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1
1
1138
18061
437
1 510
Less external load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
19
1157
0
35
1840
0
10
447
0
19
529
15
Duct loads
67%
94%
781
1733
67%
94%
302
498
Total room load
Air required (cfm)
1938
177
i
3574
195
749
68
1027
56
Calculations aggroved by ACCA to meet all requirements of Manual J 8th Ed.
wrigtr,tts�f# Righ!-SulteO Universa12012 12.0.02 RSU11227 2012-Jul-31 08:45:55Page3
nts and Setdngsllib6.LIBERTYHFATING1DesktopWendozalLotl9.rup Calc = MJ8 Front Door faces:
fir'- wrightsott- Right-M Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
Br: True Air Mechanical
Plan: Lot 19
1
Room name
MBR2
HALL2
2
Exposed wall
13.5 ft
0 It
3
Room height
10.0 ft heat/cool
10.0 ft heat/cool
1
4
5
Room dimensions
Room area
1.0 x 195.8 ft
195.8 ft'
4.0 x 13.5 ft
54.0 ft'
Ty
Construction
U-value
Or
I HT M
I Area (ft')
Load
I Area (ft') I
Load
L
number
(Btuh/ftkOF)
(Btuh/ft
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
j
6
V"12C-Osw
0.091
ne
I
2.30
3.59
0
I
0
0
0
0
0
0
0
2 glazing, Gr outr,
0.350
ne
8.85
26.86
0
0
0
0
0
0
0
0
Vt/
12C-Osw
0.091
se
2.30
3.59
0
0
0
0
0
0
0
0
10D-f
0.420
se
10.63
27.28
0
0
0
0
0
0
0
0
—G
Vt!
L--G
11
12C-Osw
0.091
sw
2.30
3.59
135
105
242
377
0
0
0
0
2 glazing, clr outr,
0.350
sw
8.85
29.01
30
0
266
870
0
0
0
0
V)/
t—G
12C-Osw
0.091
nw
2.30
3.59
0
0
0
0
0
0
0
0
2 glazing, clr outr,
0.350
nw
8.85
26.86
0
0
0
0
0
0
0
0
C
16D-30td
0.032
0.81
1.53
196
196
158
300
54
54
44
83
F
22A-tpl
0.989
25.02
0.00
196
14
338
0
54
0
0
0
61
c) AED excursion
961
1
13
Envelope loss/gain
1 1004
16441
1
1 44
80
12
a) Infiltration
288
176
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1292
2280
1 44
80
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
25
45
-44
-80
14
15
Subtotal
I Duct loads
67%
94%
1316
888
2325
2190
67%
9
0
0
04%
0
l room load
2201 204
4247
I Ao�equired (cfm)
I
I
I
I
I
I 0
0
Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed,
wriiUbtsvft 2012-Jul-31 08:45:55
Right-Suit"Unlversa1201212.0.02 RSU11227 Page4
nts and Settings11ib6.LIBERTYHEATING%DesktoplMendoza\Lotl9.rup Calc= MJ8 Front Doorfaces:
-q wrightsoftt Right-M Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
1
Room name
HALL
LAU
2
Exposed wall
O ft
O ft
3
Room height
10.0 It heaticool
10.0 ft heat/cool
4
Room dimensions
1.0 x 106.3 ft
6.0 x 8.0 ft
5
Room area
106.3 ft'
48.0 ft'
T
y I
Construction
U-value
Or
-ITM i
Area ft'
I
Load
I
Area ft'
Load
number
(Btuh/ft;°F)
(Btuh/ft2 I
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Vi/
12C-Osw
0.091
ne
2.30
3.59
0
0
0
0
0
❑
0
0
L
2 glazing, clr outr,
0.350
ne
8.85
26.86
❑
0
0
0
0
❑
0
0
--G
12C-Osw
0.091
se
2.30
3.59
0
0
0
0
0
O
0
0
1013-f
0.420
se
10.63
27.28
0
0
0
0
0
0
0
0
V+/
11
12C-Osw
0.091
sw
2.30
3.59
❑
0
0
0
0
0
0
0
�(^
2 glazing, dr outr,
0.350
sw
8.85
29.01
0
0
0
0
0
0
0
0
Vj/
12C-Osw
0.091
nw
2.30
3.59
0
0
0
0
0
0
0
0
t---G
2 glazing, dr outr,
0.350
nw
8.85
26.86
0
0
0
0
0
0
0
0
C
16D-30td
0.032
0.81
1.53
106
106
86
163
48
48
39
74
F
22A-tpl
0.989
25.02
0.00
105
0
0
0
48
❑
0
0
61
c) AED excursion
-6I
-3
Envelope loss/gain
88
157
1
1 39
71
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants (S1 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
86
157
39
71
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
-86
-157
16
30
14
Subtotal
0
0
55
101
15
Dud loads
67%
94%
0
0
67%
94%
37
95
Total room load
0
0
1
1 93
195
Air required (cfm)
0
0
8
11
Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed.
2012-Jul-3108Pa:
Rig ht-Sulte4t+Unlversal207212.0.02 RSU11227 pagee
s
...nts and Setfings11lb6.LIBERTYHEATINGOesktuplMandozalLoll9.rup Calc = MJ8 Front Door faces:
+ wrightsoft- Right-J® Worksheet Job: Avenida Mendoza Lot 19
Entire House Date: Jul 27, 2012
By- True Air Mechanical
True Air Mechanical Plan: Lot 19
1
2
3
4
5
Room name
Exposed wall
Room height
Room
Room area dimensions
Ty Construction
number
U-value
(Btuh/ftk'F)
Or
HTM
(Btuh/ft2)
Heat Cool
GREAT RM
32.0 ft
10.0 ft heat/cool
1.0 x 327.8 ft
327.8 ft
Area (ft') Load I
or perimeter (ft) + (Btuh)
Gross N/P/S Heat Cool
10.0
197.8
Area
or perimeter
Gross
KIT
0 ft
ft heat/cool
1.0 x 197.8
ft'
(ft') f Load
(ft) l (Btuh)
ft
N/P/S Heat
Cool
6
V+l 12C-Osw
�G
0.091
ne
2.30
3.59
190
190
437
682
a
❑
0
0
2 glazing, dr outr,
0.350
ne
8.85
26.86
0
0
0
0
0
0
0
0
V�/ 12C-Osn'
0.091
se
2.30
3.59
115
59
136
212
0
0
0
—G 10D-f
0.420
se
10.63
27.28
56
0
595
1528
0
0
0
0
0
11
V�V 12C-Osw
0.091
sw
2.30
3.59
0
0
0
0
0
0
0
l� 2 glazing, clr outr,
0.350
sw
8.85
29.01
0
0
0
0
0
0
0
0
Vt/ 12C-Osw
0.091
nw
2.30
3.59
15
15
35
54
❑
0
❑
0
L—G 2 glazing, clr outr,
0.350
nw
8.85
26.86
0
0
0
0
0
0
0
0
C 16D-30td
F 22A-tpl
0.032
0.81
1.53
328
328
265
503
198
198
160
0
303
0.989
25.02
0.00
328
32
801
0
198
0
0
0
8
c) AED excursion
123
60
Envelope loss/gain
2269
2855
1
160 1
243
12
a) Infiltration
683
418
0
0
b) Room ventilation
0
❑
0
0
13
Internal gains:
Occupants @
230
2
460
0
Appliances/other
0
0
1200
Subtotal (lines 6 to 13)
2951
3733
160
1443
Less external load
0
0
Less transfer
0
0
0
0
Redistribution
17
32
0
36
66
14
15
Subtotal
Duct loads
2969
3765
197
1510
67%
94%
2003
3546
67%
94%
133
1422
Total room load
Air required (cfm)
4972
7311
1
329
2932
453
400
30
160
Calculations a roved by ACCA to meet all re uirements of Manual J 8th Ed-
-.r WrivI1t-cart Rlght-Suite& Unlversal201212.0.02 RSU11227 2012-Jul-31 08:45:55
nts and Settings4ib6.L1BERTYHEATINGIDesktoplMendoxa\Lotl9.rup Calc = MJ8 Front Door faces: Page 6
wrightsort- Right,J® Worksheet
Entire House
True Air Mechanical
Job: Avenida Mendoza Lot 19
Date: Jul 27, 2012
By: True Air Mechanical
Plan: Lot 19
1
Room name
DINING
2
Exposed well
16.5 ft
3
Room height
10.0 ft heat/cool
4
Room dimensions
12.0 x 16.5 ft
5
Room area
198.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area
Load
number
(Btuh/ftk'F)
(Btuh/ft5
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
He
Cool
Gross
N/P/S
Heat
Cool
6
VI/
I��
12C-Osw
0.091
ne
2.30
3.59
165
125
288
449
2 glazing, dr outr,
0.350
ne
8.85
26.86
40
0
354
1074
V+/
12C-Osw
0.091
se
2.30
3.59
0
0
0
0
1OD-f
0.420
se
10.63
27.28
0
0
0
0
G
Vjl
L—G
11
12GOsw
0.091
sw
2.30
3.59
0
0
0
0
2 glazing, dr outr,
0.350
sw
8.85
29.01
0
0
0
0
V)/
�--G
12C-0sw
0.091
nw
2.30
3.59
0
0
0
0
2 glazing, dr outr,
0.350
nw
8.85
26.86
0
0
0
0
C
16D-30td
0.032
0.81
1.53
198
198
160
304
F
22A-tpl
0.989
25.02
0.00
198
17
413
0
61
c) AED excursion
$1
Envelope loss/gain
1215
1745
12
a) Infiltration
352
216
b) Room ventilation
0
0
13
Internal gains: Occupants (8 230
0
0
Applianceslother
0
Subtotal (lines 6 to 13)
1567
1961
Less external load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
1567
1961
15 I
Duct loads
67%
94%
1057
1847
Total room load
2624I
3808
Air required (cfm) I
I 239
2081J
Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed.
wrighisarft 2012-Jul-31 08:45:55
Right -Su ite®Universal 2012 12.0.02 R S U 1 1227 Page 7
nts and SettingsVib6.LIBERTYHEATINGIDesktop%Mendoza\Lot19.rup Cale = MJ8 Front Doorfaces:
Job #: Avenida Mendoza Lot 19
Performed by True Air Mechanical for:
Avenida Mendoza
3194 Airport Loop Dr., *C-2
Costa Mesa, Ca 92626
Level 1
True Air Mechanical
Scale: 1 : 101
Page 1
Rght-Suite® Universal2012
12.0.02 RSU11227
2012-Jul-31 08:46:19
... EATING\Desktop\Mendoza\Lot19. r.
Wri htsoft. Duct System Summary Job: Avenida Mendoza Lot 19
9 Date: Jul 27, 2012
Entire House By: True Air Mechanical
True Air Mechanical Plan: Lot 19
Y _ Pro.- Information -
For: Avenida Mendoza, Canaday
3194 Airport Loop Dr., #C-2, Costa Mesa, Ca 92626
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply / return available pressure 0.38 / 0.12 in H2O 0.38 / 0.12 in H2O
Lowest friction rate 0.320 in/100ft 0.320 in/100ft
Actual air flow 1767 cfm 1767 cfm
Total effective length (TEL) 156 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BA2
h 749
68
56
0.376
5.0
Ox 0
VIFx
17.3
85.0
st7
BDR3
c 3574
177
195
0.449
8.0
Ox 0
VIFx
15.7
70.0
st4
DINING
h 2624
239
208
0.456
9.0
Ox 0
VIFx
14.4
70.0
st3
GREAT RM
h 2486
227
200
0.458
8.0
Ox 0
VIFx
14.1
70.0
st2
GREAT RM-A
h 2486
227
200
0.345
8.0
Ox 0
VIFx
26.6
85.0
st6
KIT
c 2932
30
160
0.489
7.0
Ox 0
VIFx
8.6
70.0
st3
LAU
c 195
8
11
0.336
5.0
Ox 0
VIFx
29.7
85.0
st6
MBA
h 2689
245
175
0.327
9.0
Ox 0
VIFx
27.5
90.0
st5
MBR
c 4925
259
269
0.426
9.0
Ox 0
VIFx
20.2
70.0
SO
MBR2
c 4515
201
247
0.345
9.0
Ox0
VIFx
26.6
85.0
st7
`Mc
h 941
86
45
0.320
6.0
0x 0
VIFx
30.2
90.0
st5
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st7
Peak AVF
269
303
0.345
556
10.0
0 x 0
VinlFlx
st4
SW
Peak AVF
446
498
0.345
635
12.0
0 x 0
VinlFlx
st6
Peak AVF
235
210
0.336
532
9.0
0 x 0
VinlFlx
st2
st2
Peak AVF
462
410
0.336
588
12.0
0 x 0
VinlFlx
st3
Peak AVF
269
368
0.456
469
12.0
0 x 0
VinlFlx
st5
Peak AVF
331
221
0.320
607
10.0
0 x 0
VinlFlx
st1
st1
Peak AVF
590
490
0.320
552
14.0
0 x 0
VinlFlx
Bold/Italic values have been manually overridden
Wri heft. 2012-Jul-3108:45:57
9 Right-Suita®Universal 2012 12.0.02 RSU11227 Page 1
nts and Settings\lib6.LIBERTYHEATING\Desktop\Mendoza\Lotlg.rup Calc = MJ8 Front Door faces:
Jame
rb1
Grill
Size (in)
Ox0
Htg
(cfm)
1767
Clg
(cfm)
1767
TEL
(ft)
36.0
Design
FIR
0.320
Veloc
(fpm)
810'
Diam
(in)
20.0
H x W
(in)
Ox 0
Stud/Joist
Opening (in)
Duct
Matl
VIFx
Trunk
Boldgtalic values have been manually overridden
C wri htSO 2012-Jul-3108:45:57
�^.�C� 9 Right-Suite®Universa12012 12.0.02 RSU11227
AM ...nts and SettingsVib6.LIBERTYHEATING\Desktop\Mendoza\Lotl9.rup Calc = MJ8 Front Door faces: Page 2